Loading...
HomeMy WebLinkAboutPP - 14101 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS14101 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 09-F-123 09-5-229 09-F-078 09-S-054 17-S-043 00-5-281 ** THIS DOCUMENT FOUND IN 12101 TIB - INTERGATE WEST BLDG C ** ABU BAKR 14101 TUKWILA INTERNATIONAL BLVD TUKWILA FIRE DEPARTMENT FIRE PREVE TION/ SURVEY DATE: I ( / 2-1/ 1 q SHIFT: \ STATION. V INSPECTORS: BUSINESS NAME: /lgci RR ADDRESS: /`T// 0 1 ( SUITE # BLDG. # ZIP: 1-1/ v l APT. # MAILING ADDRESS: 54 PHONE: 246 Z (4 022-4 MANAGER/OWNER: fk/ '/1. X U'4104 2. X ` M6Lc W1H7 PHONE: 2) & - 3C -C-"203 Need Box VERIFIED THAT CORRECT KEY IS IN KEYBOX: Y Box Location MONITORED BY: Mal r OCCUPANCY TYPE: A3 SQ. FOOT: PERMIT PERMITS REQUIRED: 4--3 REQUIREMENTS OK? Y N BUSINESS LICENSE NUMBER: PREFIRE: CI -COMPLETE 0 -NOT COMPLETE 911 SCREEN INFIRMATION CITY: ZIP: EMERGENCY CONTACT INFORMATION: y PHONE: ;4:54 ' S ' (101 '1 y esk— S REVISION 0 -NOT NEEDED 70/ CODE# e w . o i' 2®-1/t u. fc 16 5 pii ,z (' j s- 'iC 14-1DSb llok4 m w8 /h Stayialdw 3 i bb 519.1 I -v Nov- 0- fi5 pacifore - gi se -4'i 2l tro+,r /! ( y 6(74 soh (190 - /3)14./,n /7 w 4 -tat , ,‘/ it/ )41pettr oN F./No 5 -14 -- OFFICE USE DESCRIPTION LOCATION 10-,P S24 Z! 41 17 r44 /6,ne'k detive + 1% Ote/C• 1'1-01 " 5 i S11 Uv 4444 Pe4fte Ct ✓Gv 11- tSvr 35S gevklipit, s)rip Afre-ike tNi_ P./4" Pel, 0-1 43-10 ,escifixat c lti fedi Class 2 te. Fire Prevention Rev. 1/30/12 T.F.D. F F.P. 12 Whi Yellow: Business /2-l2- 13 / it, z /3't, 00 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Submittal Address: 6300 Southcenter Blvd, Suite SITE LOCATION Date application accepted: 209, Tu wila WA 98188 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 1610 0 0 012 5 SE Corner Site Address: 14101 Tukwila International Blvd Tukwila 98168 Suite Number: Floor: Tenant Name: Abu-Bakr Islamic Center Property Owner's Name: ABU-BAKR ISLAMIC CTR OF WA New Tenant? ❑ - Yes ® - No Mailing Address: 14101 Tukwila International Blvd Tukwila 98168 CONTACT PERSON -if there are questions about the submittal. Name: Keith Hillstrom Company Name: Emerald Fire City State Zip Day Telephone: 253-857-2056 / 253-606-1217 Mailing Address: 11021 Cramer Road KPN, Gig Harbor WA 98329 E-mail Address: KeithH@emeraldfirellc.com City State Zip Fax Number:253-857-2312 Total number of new/relocated devices or sprinkler heads: 5 Valuation of Project (contractor's bid price): $ 1100.00 Scope of Work (please provide detailed information): Fire Sprinkler T.I. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Keith Hillstrom Plan Permit App.doc Date: 3/8/17 Day Telephone: 253-606-1217 1/2/13 TFD FP Form 8 4 L • -8 �F/LL TYPICAL INSTALLATION OF DRY PENDENT SPRINKLER IN ALL COLD STORAGE FREEZERS AND COOLERS I I 801 FOR COOLERS /2" FOR FREEZERS IN MCIfEO SPICA sorts rts 1 VAR/ES ( WET PIPE WITH MASTIC I %:11 FLOOR FLANGE THREADED PIPE SLEEVE GASKE r 1Yr. FLOOR FLANGE MI" f/SZ V4SM(N. SISN€T, ANO CONOWf Nur IN L/tU Of fLOON fLANGt CRY PENDENT SPRINKLER • ABEL FIRE PROTECTION • FAX TRANSMITTAL 206 481 8695 CROWN FIRE PROTECTION, INC. ECM 08/28/00 Lt. Thomaso FILE Tukwila Fire Department Pete's Flying Aces Tukwila,WA Number of Pages (Including Cover) 8 Fax No. 0 Urgent 0 For Review 0 Please Comment ll Please Reply Fron Jessica Robinson PH:425,481.7669 P.01 206,575.4439 J FX:425.481,8695 To follow are the hydraulic calculations for the Pete's Flying Aces project, that you requested. If you have any questions or need any additional information, please do not hesitate to call. (X:425.481.8695 P.Q. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 �,____ ABEL FIRE PROTECTION • 206 481 8695 4 3 fi fati • pr. • 1 • T0_.d 00000000000000000000 P.02 ABEL FIRE PROTECTION WIT/MOLT: t'ALCULATI&D S CROWN FIRE WASHINGTON SOTHEL� DYNAST.`': AT PETE'S FLYING ACE..: - UNDER STAGS AREA - 14101 PAC:IFIr: i?NX SOUT14 TMJ WTLA, WASHINSTON AurhGl�y having Curj 5djCtiar: C'CC:upan!:y_. .. - - - - 16'F► r - _7,:;v re pax 3prinki9: _ Sys em type-- - Water riup3ii _. Sprinklers ^- Demand '=FFA ;RDINF.R.Y HAZARD G,E' I 0.13 Spm sq. f t . - 6 UNDER 5 AaE 4EAU; FLOW:NG -. S.F. MAX 206 481 8695 $heat 1 +f Dais 0a.,'27/CC Job; FLYING2 Wet m Outside Hose 150.0 gpm Inside H ase, 25,x0 ,0 gpm p39. 5t;a.t' w .O.0O psi pesidue3i @ 1120.C° gpm K=5.6 2.1.55 pei i 204.7 .fpm 0 B.D.R. - 4.0.R- - 24.03. psi @ 604. " oir f Supply 57.41 psi available @ 604.? rpm Demand is below CL' eve by 33.40 psi. P.03 ABEL FIRE P OTECTION CROWN FIFE sROIECTION Doecriptt * of rift -Jig abbreviations ;'rOuu Description rM T Tte Mit sty degree elbow v'r vlctaulie tell; VE vjctau1io ninety degree elbow ALV Alarm valve: Grinr.ell. 120t, ;2001 nax RecAflow: Amar 20 es/30009s Silver 'bullet BV Butterfly valve UE t nda_r•grocna RSCA ninety .legree B :bqw Description Othe-• a'rsbreviatOrts , r ?.¢ _ke_1 0 P. 04 Sheet 2 M1 7.04Q Description • , AO Arm -over BL $ISelcr ,stn CM Cross Maih E'T Total presauxe PS Pressure loss due to elevation changes P Pressure loss due tt fr .ttcn RAisiid to the power ;.:x (SSgvare Rost) A Actual pipe length 1 3 w� t� Fitting equivalent, pl a Se ' . 'i' Total pipe 1engtb . • • • . r. • ABEL. FIRE PROTECTION CROWN Sprxnkler Systema :YNASTY AT 1.410' PACIFIC HW1 296 4$1 6695 P.05 Qoseeeeesee. .41, 0etase P. 64 /RE PRC T EC1 ION Wraulse Flow Calcula.icns PET 's FLYING ACES 4OUi!}1 TUKWILA, WASHXNGTCN Rare, data previa. tu5 to any Gaiculations . Code Diem Length Kfac1 4 3 5 9 6 7 A01 A0.7. ELI ELI %sT7 aL2 cmi CM. 901 RU1 EUI R11. 6 UG ;..0e7 1.087 2.007 1.416 1.650 1..0x77 1.067 1.6.50 2.115 2.115 4.328 6.357 6.357 6.140 6.140 3.5 3.r; 0.5 1.5 2.5 10-0 2.5 6.0 2.5 63.0 01.0 46.0 10.0 Sheet 3 Kfae2 Press Rlev Hose HW Vel Fittings 5.6 S.4 5.6 A01 5.6 5.6 5.6 A02 RIA 8L2 CK1 $y1 95.0 RIi 0.6 7.00 0.00 0.0 12: 2 1T 7.00 0.00 0.0 120 32 2E 7.00 0.00 0.0 1::0 0.00 0.00 0.0 120 32 7.50 0.00 0.0 120 32 1T, 7.00 0.00 0.0 120 32 7.00 0.00 0.0 120 32 1T 0.00 0.00 0.0 120 32 0.00 0.00 0.0 120 32 ,, 000 -7-00 0.0 120 32 6G,1T 0.00 0.00 0,0 120 32 1VT 0,00 0.00 0-0 120 32 iVE 0.00 11.00 0.0 120 32 vE,1 LV.1Rv.1au 0.00 0.00 150.0 140 32 3JE 0.00 0.00 250.0 140 32 c• F (Qpm) :rover' 1 •+d * -sw �l►-ac - _____ ;;a( l 1- FIRE PROTECTION 2136 481 0695 P.e 1�tairo seeetert► � eeeVe P. + 5 • S4lier 4 SPankler Pia (inch) 14101 '..7,ROWk4 FIRE PROTECTION yatems; `iydlrsulf.< Flow Calculations TT AT HTE E1YING ACES* T `1C HWY 8t`OTH 71.004ILA. 8A0ezNo Fitting arid 00V 14.806.60(7.00)'.5 14.8 1.09 1T Lengt 1 (ft) Fr Lass Press Hyd %'el (pslift) (psi) Ref (fps) • h 3.5 PT 7.00 1v1 6. C.� O. /i �% PE ' 0.00 . a 9.5 Y� .'{F621 2 PR. 0.59 PT .7.59 4 K7facto r for arm -over 1 - 14.8/(7.59)".5 a 5.37 • m -over 2 14.0 1.00 A F 2m1, K-factpr for arm -over anch1ine No. 1 (Beginning pow..www.0 w..= 14.9.05.60(7.08)^.5 3 14.9 1.03 14.8=5.37(7.60)^.5 4 29.7 1.42 15.5'0.5.60(7.69)'•.5,.. 5 45.: 1.65 3.0 PT 4.8 PE 7.a 0.06282 E'E' PT 77p.00 2 0 . C 0.49 7.49 c 2 - 14.8:(1.49)".5 w 5.41 preaeute increased dub to Hyd A 8.a PT 7,06 F 0.0 PC 0.00 0' 8.5 0.06332 PF 0.54 A 1.5 PT 7.60 F 0.0 2E 0.00 1' 1.5 0.06268 Pr 4.09 A 2.5 PT 7.695 F 9.0 PE 0.00 1T T 11,x, 0.06483 Par 0.15 PT 8.44 • Note') •Cr110 • S'1 Jct C=120 B1 Jet Ref pt 4) C . 127 3 End head 5.14 6.05 K-farror for branc;r.line no. 1 . 45.2/(8.44)^.5 w 15.56 :a►nchline No. 2 . - A 10.3 PT 7.e0 6 14.8.65.50(7.00)^.5 F 0.3 PF 0.00 14.3 1..39 T 10.1 0.06282 PF 0.63 5.)2 A 2.5 PT 7.63 F' 6.) PE 0.00 11 T 9.5 0.23574 Fr 1.99 10.47 PT 9.62 9 Cross mein Jct 15.5w5.60(7,63)",5 30.3 1..09 cross ruin tint c s 120 End head; K -factor for branchli.ne no. 2 30.3.(9.62i9.5 - 9.77 F • e Plow Dia A4E;1; FIRE PROTECTION Sheet MOW UBE PROTtCTION Sprinkler Sys ews f ydr1U110 £ldat Calcalet_lcar.s DYNA;; Y AT tr?r.' S 4'LY%N s P1t 113 .4.1.01 PAM= HPI? OUP TUK' ILA. 18,ASKI4GTUN Fr Loss press Hjd 'lel (Psi/ft) Fitting a t d D$' Lengt r (ft) ss mem 1 (Seginni.ng pressure :,.�:.Y.. K.420.97•.5.41.1.1.5.56 Ct. 9.dri0.97(8.b0;^.5 61.9 1.6S 303.-9.77(9.63)4.5 92.2 2.12 9 A lE T (psi) Ret apes) itv.reased dwe to Hyd Ref Pt g) 8.0 rT 8./0 3 0.0 Pt 0,00 8.0 0.11574 PF 0.D PT 9.63 `'S 5.6 PE 0.00 8.1 0.0'122.4 PP PT 1 , 058 10 y-raCtc)r for Cross main 1 9- .2i t1"v. ;i ' .5 28.P5 at Hyd R f. Pts 10 36 8.42 rotes C¢ 120 RO2 + BLit S2 i�ulk Jct P. 0Z • s= -Air 3prink RSEL. CROWN i t_ 3Xst'stma 14 TT iTT A' 1410_ M r WY Die = itt .ng 4 inch) and bate 92.2-28.85,30.211".5 12.2 3.12 GE 1T 92.2 112.5- 6 204.7 .sec 1 . 4.33 IVT I.8S(1.20)A.5 6.36 1VE FIRE PROTECTION 2106 481 0695 P.06 easyb !eall 6Ai9'ltits"OraPt$okkits - P.:07 c,heet 6 IRE PROTECTION /drauli^ Flow Calculations BETE 1 S 'MY/NG Agss lotyro T0RWJtA, W18E+INGTON Letlgti• Cr Loss Press Hyd (ft) (p 1.t t) tps,.) Rel` tipsy A T A k T A t r. 64.0 44.7 108.1 d8.0 22.8 70.8 46.3 12.6 58.6 PT PE 0.07230 PF PT PE 0.00221 PF P1• PE 0.00149 PF PT .x • i v . r 65,4 PE 0 204.7 6.•36 2v_E l.ALV T 75.4 0.00149 PP 1 EN '1611 PT :Oar ground a = •fi 95 5 P'" 150.41 qpm . Hose • • F 30.0 PE ae 354:7'.: 6.14 31.E T •125.0 0.00366 PP A 0.0 PT 250.0 gym m Rose . F 0.0 • PE 39 €014 , 7 6.14 9.0 0,00000 PF 10.21 10 -3.0$ 7.86 13.04 11 0.00 0.16 15.20 0.00 0.09 15.28 37 15.29 37 4.76 3.50 2:.55 3:1 2:1.55 3; 0.00 0.46 24.0•', 39 0:00 0.00 24.01 40 8.42 2.01 3f 2.07 Notes r- 124 CM t -7.00 ,ft . CM - 'roc .. Toe er R1 (3r c = 120 Tars of Riser (EL.. 11.00 ft: 2.07 inii O 3.34# D.R. 3.t�4 /ailable f1:ow. at 24.01 psi. is 1075.1 gpm whict; is 410.4 gom from t=PPiy RreaSure • Va11ab1e with 604.. gpm fllow .ttg in 57.41 psi, hus wistem•regui einent is 33.40-ps1 below supply•eurve.• (M1..24 • • C = i40 6.`.R. 8*3001Y Jot. curve. • • • � - ..r:moi:�f • ABEL FIRE PROTECTION FAX TRANSMITTAL 206 481 8695 P.01 Fax No_ CROWN FIRE PROTECTION, INC. tom: Company 07/19/99 Lieutenant Thomaso Tukwila Fire Department Hydraulic Calculations Number of Pages (including Cover) El Urgent Cl For Review 10 0 Please Comment C?f Please Reply 206.575.4439 bon Jessica Robinson PH:425.481.7669 FX:425.481.8695 Comment: To follow are the hydraulic calculations for the Flying Aces project. if you have any questions or need any additional information, please do not hesitate to call. Thanks and have a great day! P.D. BOX 12113 MILL CREEK, WA 98082 PH: 425.481.7669 FX:425.481.8695 ABEL FIRE PROTECTION HYDRAULIC CM CULATIONS CROWN FIRE PROTECTXQN BOTHELL, WASHINGTON Job__ _ FLYING ACES SPORTS BAR 14101 PACIVXC HWY SDUTH Auth ority having Jurisdiction_ Occupancy_ _ _ Density - __ ._ _ Area of Application Coverage per Sprinkler System type... _ wet Hose --_---.,_150.0 water Supply - 75,00 Sprinklers - K=5.6 Demand_-�_ SPRINKLERS AT Tutcwll.n, WASHrtyGTON NFPA ORDINARY HAZARD GP I mis.30010 square feet 130 S.F. MAX 206 481 8695 P.02 00000C#0000o00e34300000 P.01 Sheet 1 of 9 pate 06/28/99 Job: FLYING Qpm Inside Hose. 250.0 gpm Outside Hose Psi Static, 20.00 psi Residual @ 1120.0 gpm 28.29 psi 0 594.8 gpm a B.O.R. 30.09 psi @ 994.8 gpm @ Supply 30.83 psi available ill 994.8 Demand i s below curve by 0.74g - 74ppsi 141 x 8' 112 SF X .13 = 14.6 GPM / 7.0 PSI MIN END HEAD PSI )UE TO DEFICIENT WATER SUPPLY TOTAL OUTSIDE H05E AVAILABLE IS 250 GPM VS iGO GPM WSRH RECOMMENDATION ABEL FIRE PROTECTION CRDwN iIR£ PROTECTION Description of Fitting abbreviations code Description T Tee E Ninety degree elbow VT Victaulic tee VE victauli ninety degree elbow ALV Alarm valve: Grinnell c200, 0001 B71 Batkflaw: Ames 200Oss/3000ss Silver gullet By Butterfly valve UE Underground ASCA ninety degree elbow Description of other abbreviations Code Description AA Arm --over DR Drop BL Branch Line Rei Riser Ni+pl e CM Cross main PT Total pressure PE pressure loss due to elevation changes PF Pressure loss due to friction A.5 Raised to the poWer of .S (Square Root) A Actual pipelength Fitting equivalent pipe length T Total pipe length 20E. 481 8695 43l1bIdb:lk?k}4^Vk!'ti: KdtiK: S:I�.•�c.ar •1u sheet 2 ABEL FIRE PROTECTION 206 481 8695 000$+0$1011000s7ur,vti- y _ Sheet 3 CROWN FIR PROTECTION Sprinkler systems 0ydraulic flaw Ca)CulatiOils PLYING, ACES SPOR T S OA AR WASHINGTON 14101 PACIFIC HWY SOUTH Raw data previous to any calculations El ev Hose ft vel Fittings Code Diam Length Kfacl KfacZ PfesS 2.00 0.0 120 �2 1E 2.0 5.6 7.07.00 -2.00 0.0 120 32 1E _ on2 1.087-4.003 0.0 120 32 LE 0R3 1.087 3.0 5.6 7.000.0 120 32 1E QR3 1.087 4.0 S.6 7.00 -5.00 1 DR4 1.087 5.0 S.6 0.00 0.00 0.0 120 32 2T,1E 5 A02 1.087 1.5 0R2 0.00 0.00 0.0 120 32 2T.1E 1 A02 1.087 1.5 0R3 0.00 0.00 0.0 120 32 2T.1E A0 1.087 1.5..5 0R4 0.00 0.00 0.0 120 32 2T,1E 8 A04 1.087 0 ,014 0.00 -1.00 0.0 120 32 0 811 1.416 .12.0 A02A0.00 -1.00 0.0 220 32 0 811 1.416 12.0 3 0.00 -1-00 0.0 1..20 32 RL1 1.60 13.0 A04 0.00 -0.20 0.0 120 32 11 2 RL1 1.650 0.00 -0.80 o.0 120 32 .4 BL2 1.417 7.0 PRI 0.00 -0.80 0,0 120 32 :a 8L .416 10.0 0R71 0.00 -0.80 0.0 120 32 16 8L2 1.4165 7.0 oR3 0.00 -1.00 0.0 120 32 1. 812 7.315 12.0 IDR3 0.00 -0.80 0.0 120 32 2E,1T L8 L 1.087.87 13.0 bRa 0.00 -0.80 0.0 120 32 18 8L3 41 10.0.0 S.6 7.00 -0.80 0.0 120 32 2 813 1.416 5.6 7.00 -0.80 0.0 120 32 20 813t 1.6506 7.0 0R3 0.00 -1.00 0.0 120 32 212 83 115 12.0 [?R4 0,00 -0.80 0.0 120 32 2E,1T 23 813 2.087 13.0 5 6 7.00 -0.80 0.0 120 32 23 RLa 1.41 0.0 120 32 24 81 1.46 37 0 5.6 7.00 -0.80 0.0 120 32 2526 8L4 1.416 7.0 5.6 0.00 -1.00 0.0 120 32 27 814 2.115 12.0 DR4 0.00 -0.80 0.0 120 32 2E.11 RPJ 2.115 13.0 811 0.00 1.50 0.0 120 32 1T 28 RN2.115 1.5 812 0.00 1.50 0.0 7.20 32 11 29 RN2 2-115 1.5 811I 813 30 RN3 2.115 1.5 1 $1.4 0.00 1.50 0.0 1207 32 1T 32 1T 31. RN4 2.115 1-5 811 81.3 0,00 0.00 4,0 120 32 32 CM1. 4.328 8.0 RN1 0.00 0.00 0.0 20 32 33 Cwt 4.328 8.0 RW2 0.00 0.00 0.0 120 32 345 041m 4.328 8.0 RN3 0.00 0.00 0.0 120 37 1vT 35 [w1 4.357 40.0 CM4 0.00 0.00 0.0 120 32 1VE 367 Oa 6.357 16-0 Cu3 0.00 11.00 0.0 120 32 37 RI1 6.357 34.4 BU1 2VEJAL.v,1aV,18 1 38 UG 6.140 95.0 Rz1 0,00 0.00 250.0 0 150.0 140 32 30E 39 taG fi -1.41 0 P. 04 00000000000000000000 P. 04 CROWN FIRE PROTECTION sprinkler Systems Hydraulic Flow Calculations Dia (inch) FLYING ACES SPORTS BAR 14101 PACIFIC HWY SOUTH TUKWILA, WASHINGTON Fitting and pay LerI9th Fr .oss (ft) (psi/ft) a ] tl pT PrR$$ (psi) Sheet 4 MO V 1 Ref (fps) 7 An 1 Notets c = 120 .14.8=5,60(7.0O)A.5 F 7.4 pi -0.87 1 (EL,2.00 ft) 1 14.8 1.09 1E T 4.4 0.06282 PF 0.28 5.12 PT 6.41 5 si JCt; K -factor for drop 1 = 14,8/(6.41.)+.5 . 5.85 at Hyd Ref Its S 13 14 18 rop 2 c = 12e .-..==. ABEL FIRE PROTECTION 201 481 8695 P. Fay eleil000ele0000000et000kw Sheet 5 CROWN FIR PROTECTION 5prinklmr System; tiydraulie, Flow Calculations FLYING ACES SPORTS BAR 14101 PACIV1C HWY SOUTH TUKWILA, WASHINGTON ,e Flr}W Dia Fitting Leflgth Fr LOSS Pro!S Hyd Vel (gpm) (inch) and oev (ft) (psi/ft) (psi) Ref (fp6) raOteN C 12(1 1 -over 2 1, 5 PT 60.04 6 Orr- .z14.S 6ua2(6.04)^.5 F 14.3 0 i 14.8 1.09 2T 1E T 15.8 0.06269 pT 0.09 1.0 5.12 al lt K -factor for arm -over 2 = 14.8/(7.03)" 5 - 5.58 C 120 .-over 3 PT 5.67 7 DR3 X1. 14.86.22(5.67)A.S A 14.3 re 0..00 7 14.8 1.09 2T 1E 1 15.8 0.06269 PT 6.99 5.12 11 $1 ]ct K -factor for arm --over 3 - 14.8/(6.66)15 = 5.74 � 120 .m -over 4 i. 5 P1 5.30 8 Q 4 8 14.8-6.1.09.30)A• 21 1E T 14.3. 0.06270 PE 0.00 5.12 PT 6.29 12 e1ict x -factor for arm -over 4 = 14.8/(6.29)".5 ¢ 5.90 C=124 ranchline Na, 1 A 12-0 P7 7.40 A4). s�aa�=s.='max m� A•5 F 0,0 PE -0.43 (EL-- -1,00 ft) 9 14.8 1.09 T 12.0 0.06269 PF 0.75 5.12 A02 a 12.0 PT 7.72 10_ -1.00 ft) 10.3=5.5842.72)x+.5 F 12.0 0,06515 PP 0.78 6.18( 10 30.3 i-42 2,0 PT 8.07 11 A03 16.3 -S.74(8 -07)n.5 F A 10.0 PE -0.43 (EL- -1.00 ft) 11 46.6 1.42 T 12.0 0.14438 PF 1.71 9.49A PT 9.37 12 18.1=5.90(9.37)".5 F 9.0 AO4 PIE -0.09 (EL. -0,70 f0 ) 12 64.7 1.65 1T 10.0 0.12567 PF 1.51 PT 10.79 28 9�Riiser Nipple 1Ct K -factor for branch3ife no. .4 64.7/(10.79)15 T. 19.70 at Hyd Ref Pts 28 29 30 31 ABEL FIRE PROTECTION 20E. 481 8695 P.06 CROWN FIRE PROTECTION Sprinkler systems Hydraulic Flow Calculations FLYING ACES SPORTS BAR 14101 PACIFI.(: HWY SOUTH TUKW.LLA, WASHINGTON pe Flow Dia 10 (nm') (inch) 'anchline No. 2 -_- .V__==_=i1W,== sheet 6 Fitting Length Fr Loss Press Hyd Vel and oev (ft) (,psi/ft) (psi) Ref (fps) A .3 14.$ 5.1.09.41.)A.5 T A 14.9=5.$5(6.50)~.5 .4 29.7 1.42 T A 15.7,6.02(6.78)".5 F L5 45.4 1.42 7' A 16.9=6.22(7.40)A.5 16 62.3 1.65 T A 18.6=6.43(8.37)A.5 F L7 80.4 2.12 2E 1T T 7.0 PT 7.0 0.06269 PF 10.0 PT 10.0 0.06277 PF 7.0 0.0 7,0 12.0 0.0 12.0 13.0 22.4 35.4 IC -factor for branchline no. 2 iser Nipple (Top of RN .sranchline 1 =_-= 4S.24=19.70+25.54 A 1.5 148.6=45.24(10.79)A.5 F 11.2 28 148.6 2.12 1T T 12.7 0.13752 0.11730 0.05677 PT PE PF PT PE PF PT PE PF PT 6.41 13 -0.3S 0.44 6.50 14 -0.35 0.63 6.78 15 -0.35 0.96 7.40 16 -0.43 1.41 8.37 -0.35 2.01 10,03 5.12 6.05 9.25 Notes C=12(► PR2. (EL= -0.80 ft) DR1, (EL,- -0.80 ft) 012 (0-= -0.80 ft) (EL= -1.00 ft) 5.35 17 0R4 (EL= -0.80 ft) 7.39 28 Riser Nipple Jct 80.9/(10.03)A.5 = 25.54 + Rranchline 2) C - 120 PT 10.79 28 BL1 + RL2 PE 0.65 (EL= 1.50 ft) 0.17481 PF 2.22 13.57 PT 13.66 32 Crags maim ict K -factor for riser nipple = 148.6/(1.3.66)A.S = 40.21 ABEL FIRE PROTECTION 206 481 2695 P.07 0000000000000ks000000 P.07 Sheet 7 CROWN FIRE PROTECTION sprinkler systen►s Hydraulic Flow calculations FLYING ACES §POKTS BAR 14101 PACIFIC HWY SOUTH TUKWILA, wASHINGTON ipe Flaw Uialne Fi0nv Lengthf(psi%ft) (psi) Hyd (fps) l NO (9Pm) (inch) and U�av ranchline No. 3 (Beginning pressure increased due ====. A 7.0 PT 15.4=5.85(0.$9)A.5 r 0.0 PE 18 15.4 1.09 T 0.06699 PF A 14.8=5.60(7.01)A,5 1K T 19 30.2 1.42 15.1=5.60(7.31)A.5 20 45.3 1.42 17.5=6.22(7.92)A.5 21 62.8 1.65 A F T A F T A 19.2m6.43(8.92)A,5 F 22 82.0 2.12 2E 1T T 7.0 10,0 0.0 10.0 0.06458 7, Z:8 7.0 0.13704 12.0( 0.0 12.0 0.11905 13.0 22.4 35.4 0.05820 K -fa or for brancbl'ne no. 3 r at Hyd Ref Pts 29 31 ti ser Nipple (Top of Rte .8ranchl i ne 1 tt44 . $519.70+25.1.5 A 1.5 3.47.3=44.85(10.79)A.5 F 11.2 29 147.3 2.12 1.T T 12.7 PT PE PF PT PE PF PT PE PF PT PE PF PT to Hyd Ref 6_89 18 -0.35 0.4/ 7.01 19 -0.35 0.65 7.31 20 -0.35 0.96 7.92 21 -0.43 1.43 8.92 22 -0.35 2.06 10.6A Motet Pt 19) c - 120 Ott1 (EL= -0.84 ft; 5.30 (EL. -0.80 ftp 6.15 (CL-. -0.80 ft) 9.23 OR3 (EL= -1.00 ft) 9.42 �DR4 (EL- -0.80 ft) 7.49 29 Riser Nipple Jct 82.0/(10.63)A_5 = 25.15 + aranchline 3) PT 10.79 PE 0.65 0.17207 PF 2.18 PT 13.62 K -factor for riser nipple d 147.3/(13.62)A_5 . 39.91 tier Nipple (Top of RN-sranchline 1 -_=== K=44.85.19.70+25.15 A 1.5 147.3=44.85(10.79)A.5 F 11.2 31 147.3 2.12 1T Y 12.7 c = 120 29 8L1 + 8L3 (EL= 1.50 ft) 13.45 33 Cress main Jct + 8ra.nchline 3) C = PT 10.79 31 RL1 + PE 0.65 (EL= 1.50 0.17207 PF 2.18 13.45 PT 13.62 35 Crass main K -factor for riser nipple n 147.3/(13,62)A.5 39.91 3,20 E1.3 ft) act Flow (gPM) ABEL FIRE PROTECTION 206 481 8695 Sheet 8 CROWN AFIRE PROTECTION Sprinkler Systems Hydraulic Flow Calculations FLYING ACES SPORTS BAR WASHINGTON14103. PACIFIC HWY sOuTR TUKWILA Fitting Length Fr Loss Press ReVol ) (inch) Dia and trey (ft) (psi/ft) (psi) f (fps) nchline No. 4 A ; ,t3 PT =====.7 -. PE 4.85-1 09.003.5 F 7.0 0.06282 PC 14.8 A 1Q.0 PT QE 14.92.--5.60(7.09)A.5 F10.0 0.06286 PF 29.7 1.42 A 7.0 PT 15.2=5.t,0(7.38)A•S F 0.13500 PF 0.0 PE 44.9 1,42 A 11.0 PT 17.6=-6.22(7-97)h!.S F 10.0 .0 0.11798 PF PE E 6 62.5 1,65A 13.0 PT PE 1.-6.41g.96)�-2E 1T T 35.4 0.05786 PF 811.77?_..12 PT 7.00 23 -0.35 0.44 7.09 24 (ELS, -0.80 ft) -0.35 6.060.63 7.38 25 -0.35 (et. -0.80 ft) p.$5 9.16 ptt3 7.97 26 _0.43 (EL= -1.00 ft) 1.42 9.38 DR$ -0.353S 8.962? (EL'= -0.80 ft) 2.05 7.46 7Ct 10.66 30 Riser Nipple (EL= 5.12 NOt4S C - 120 - 0.80nft) � K --factor for brafchline no. 4 . 81.7/(10.66)A.5 25.03 iser Nipple (Top of RN .sranchline 1 + BranchlPT 10.79 ine 4) mm=7_=m K.44.,72.19.69{25.03 A 1•S PE 0.65 146.9.044.72(10.79)A.51T F 11 .2 0.17118 PE 2.17 30 146.9 2.12 PT 13.61. 30 (ELm 13.42 34 Cross K -factor for riser nipple 146.91(13.51)4*5 = 39.82 :ross Main 1 j,Q_,.r�yrQ�aaG 146.6=40.21(13.66)&.5 32 148.6 4.33 147,7=39.91(13.70)4.5 33 296.3 4.33 148.2=39.82(13-$5)A.5 34 444.5 4.33 35 A F T A T A F T A 150.3.-39.91(14.18)N.5 f 594.8 4.33 C = 120 811 L4 .50 ft) main 3 Ct 8.0 P7 13.66 32 PF 0,00 0.0 0.00535 PE 0.04 8.0 PT 13.70 33 0.0 PE 0.00 8.0 0.01917 PF 0.15 34 08.0 PT PE 0.00 $,0 0.04060 PP 0.32 60.0 PT 14.18 35 22.8 PE 0.00 82.8 0.06958 PF PT 19.94 36 K -factor for Gross main 1 - 594.8/(19•94)A.5 133.22 3.24 6.46 9.69 12.97 C 120, RN 28 RN#Z ', RK430 Rt4iF31 t u1k. 3ci: P.08 ABEL FIRE PROTECTION 20E. 481 a695 P.09 0000000000Q000000000 P.09 CROWN FIE PROTECTION Sprinkler Systems Hydraulic Flow calculations FLYING ACES SPORTS NAR 14101 PACIFIC HWY %duiM TUKWILA, W,e NxNGT4n+ ►e Flow Dia Fitting (spm) (inch) and oev lk 1 Length Fr Loss (ft) (psi/ft) A 594.8,133.22 19.941^.S F i 594.8 6.36 1YE T 1 594.8 6.36 46.0 PT 12.6 PE 58..6 0.01070 PF PT sheet 9 Press Hyd vel (psi) nef (fps) 19.94 36 0.00 0.63 20.56 37 A 10.0 PT 20.56 i 65.4 PE 4.76 2vP IALV r /5.4 0.01070 PP 2.96 18V 1811 PT 28.29 der ground 150.0 gpm = Hose 8 744.8 6.14 250.0 9P Nose 9 994.8 6.14 Bailable flow at A 9S_0 PT F 30.0 PE 3uc T 125.0 0.01444 PP A 0.0 PT F 0.0 PE T 0.0 0.00000 PF PT 28.29 0.00 1.81 30.09 0.00 0.00 30.09 6.01 Note. C = 120 CM 1 Twp of Riser C 120 37 TOP of Riser (EL., 11.00 ft) 6.01 1811. 2.16# 38 0.0.R. c 140 38 0.0.x. 8.07 39 10.78 40 Supply lct 30.09 psi is 1003.$ gpm which is 9.0 gpm from curve. LppLy pressure available with 994.8 gpm flowing is 30.83 psi, MS system reruirement is 0.74 psi below supply curve. (2-4%) 4 A TYPICAL INSTALLATION OF DRY PENDENT SPRINKLER IN ALL COLD STORAGE FREEZERS AND COOLERS �: 1 8" FOR COOLERS 12" FOR FREEZERS /N Nf4 1V SPACZ A1OVe /OILS • VAR/ES \\\\\\\N 1 WET PIPE • 11 • FILL WITH MASTIC / %z FLOOR FLANGE G.4SKET /1/4- THREADED PIPE SLEEVE .17 ---GASKET /Yz' FLOOR FLANGE MAY UST MASNLR, SASNLT, AND CDNowT NUT IN 41(U DF FLOOR ALA/VOL DRY PENDENT SPRINKLER GIobal - Project Values. Project Name: Abu-Bakr Standby Hours: 24 itSILENT i KNIGI I'1' Project ID: Alarm Mins: 5 Prepared By: Roy L. Cats Derating Factor: 1.2 5700 Calculations Date: 8/7/2009 Voltage Drop Waming Version 02.24.09 Threshold %. 10 Panel ID: 15700 Model: 5700 Add. Fire Alarm Control Panel Max NAC Current: 2.5 Amps Location: S/W Hall Volts: 24 VDC Max Panel Current: 2.5 Amps Current Draw Ckt.# Circuit Name Qty Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts @ ° & Type 1000 Ft. One -Way Ohms EOL °Drop 5700 5700 CTRL Panel 1 0.200 0.325 , , SD500-AIM Addr. Input Mod 0.000 0.000 SD500-MIM Mini -Input Module 6 0.003 0.003 SD500-ARM Addr. Relay Module 0.000 0.000 SD500-PS Addr. Pull Station 7 0.004 0.004 SD505-AIS Addr. Ion Smoke Det 0.000 0.000 SD505-AHS Addr. Heat Detector 0.000 0.000 SD505-APS Addr. Photo Smoke Det 1 0.001 0.001 SD505-DUCTR Addr. Duct w/Relay 0.000 0.000 SD505-DUCT Addr. Duct 0.000 0.000 SD500-ANM Addr. Notification Module 0.000 0.000 SD500-LED Addr. LED Module 0.000 0.000 SD500-SDM Addr. Smoke Det. Mod. 0.000 0.000 SD505-6RB Addr. Det. Relay Base 0.000 0.000 SD505-6SB Addr. Det. Sounder Base 0.000 0.000 SD505-61B Addr. Det. Isolator Base 0.000 0.000 SD500-LIM Line Isolation Module 0.000 0.000 5860 LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 NAC #1 NAC #1 0.000 0.868 #16 Solid 4.02 125 1.01 19.53 4.28% NAC #2 _NAC #2 0.000 0.839 #16 Solid 4.02 150 1.21 19.39 4.96% Total Standby Current (Amps) 0.228 2.065 Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 5.465 0.172 Total Alarm AH Required Total Combined AH Required 5.64 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 6.76 Configure Circuits Print Page ) SILENT KNIca l'I Circuit Configuration Project Information Project Name: Abu-Bakr Prepared By: Roy L. Cats Project ID: 0 Date: 8/7/2009 Ckt. Number: NAC #1 Ckt. Name: NAC #1 Panel ID: 5700 Use: Aux Power Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 Gentex GEC324 Horn/Strobe (75cd) 0.000 0.158 0.000 0.316 6 Gentex GES324 Strobe (30cd) 0.000 0.092 0.000 0.552 Gentex GES324 Strobe (30cd) Unused 0.000 0.000 0.000 0.000 Unused Unused 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.868 Ckt. Number: NAC #2 Panel ID: Ckt. Name: NAC #2 Use: 5700 Aux Power Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Gentex GEC324 Horn/Strobe (110cd) 0.000 0.195 0.000 0.195 2 Gentex GEC324 Horn/Strobe (30cd) 0.000 0.092 0.000 0.184 5 Gentex GES324 Strobe (30cd) 0.000 0.092 0.000 0.460 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.839 — Values: Global Project ti Project Name: Abu-Bakr Standby Hours: 60 ItSILENT KNIGHT Project ID: . Alarm Mins:) 5 Prepared By: Roy L.Cats Derating Factor: 1.2 5496 Power Expander Calculations Date: 8/7/2009 Voltage Drop Waming Version 02.24.09 Threshold % . 10 Panel ID: 5496 Model: 5496 Power Expander Max NAC Current: 3.0 Amps Location: Volts: 24 VDC Max Panel Current: 6.0 Amps Part.# Description Qty Current Draw Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts @ & Type 1000 Ft. One-Way Ohms EOL 0/Drop 5496 5496 Pwr Module 1 0.040 0.160 NAC #1 NAC #1 0.000 0.862 #16 Solid 4.02 150 1.21 19.36 5.10% NAC #2 NAC #2 0.000 0.916 #16 Solid 4.02 150 1.21 19.30 5.42% NAC #3 NAC #3 0.000 0.445 #16 Solid 4.02 175 1,41 19.77 3.07% NAC #4 Not Used 0.000 0.000 #16 Solid 4.02 0.00 20.40 0.00% Total Standby Current (Amps) 0.040 2.383 Total Alarm Current (Amps) Standby Time In Hours 60 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 2.400 0.199 Total Alarm AH Required Total Combined AH Required 2.60 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 3.12 Configure Circuits ) l Print Page SILL•:N'I' KNIGHT I'I Circuit Configuration Project Information Project Name: Abu-Bakr Prepared By: Roy L.Cats Project ID: 0 Date: 8/7/2009 Ckt. Number: NAC #1 Ckt. Name: NAC #1 Panel ID: 5496 Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 Gentex GEC324 Horn/Strobe (30cd) 0.000 0.092 0.000 0.276 3 Gentex GES324 Strobe (30cd) 0.000 0.092 0.000 0.276 1 Gentex GCS24 Strobe (30cd) 0.000 0.130 0.000 0.130 1 Gentex WGEC Horn/Strobe (75cd) 0.000 0.180 0.000 0.180 0.000 0.000 0.000 Totals 0.000 0.862 Ckt. Number: NAC #2 Panel ID:. Ckt. Name: NAC #2 Use: 5496 Notification Appl Circuit • Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 Gentex GEC324 Horn/Strobe (110cd) 0.000 0.195 0.000 0.390 1 Gentex GEC324 Horn/Strobe (75cd) 0.000 0.158 0.000 0.158 1 Gentex GEC324 Horn/Strobe (30cd) 0.000 0.092 0.000 0.092 3 Gentex GES324 Strobe (30cd) 0.000 0.092 0.000 0.276 0.000 0.000 Totals 0.000 0.916 Ckt. Number: NAC #3 Panel ID: Ckt. Name: NAC #3 Use: 5496 Notification Appl Circuit v Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 Gentex GEC324 Horn/Strobe (110cd) 0.000 0.195 0.000 0.195 1 Gentex GEC324 Horn/Strobe (75cd) 0.000 0.158 0.000 0.158 1 Gentex GEC324 Horn/Strobe (30cd) 0.000 0.092 0.000 0.092 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.445 et Is ami om unity center 14101 Tukwila International blvd. 5/12/09 k This document is intended to describe the scope of work and parts related to the repair of the fire system at the Islamic community center located at 14101 Tukwila Internatio blvd. We Allied Fire & Security) Intend to repair the fire system at the above location by replacin the circuit board at the community center with a like panel UL listed for fire. This panel : a Bosch D7412GV2 fire panel. After replacing the panel we will locate a smoke dete tor above the fire panel, attach the NAC circuits and connect the existing sprinkler m ► nitoring equipment to the panel. Also we will be reinstalling a Radionics D1256 fire . eypad at the entrance of the building for control. After doing this we will test the fire system to verify operation. Aft .r the building improvements have finished we will at that time provide another sco ►e of work for updating the horn circuits and anything else that may need to be brung u to code after the new building layout is finished. tic LJ Per, �.. • Thew piens 1i%S'.+t; "•, •f isll : u' Sle i PrPreventionr�t,trr4�.,t,,,. steno:bids. A� tv,,; i':<i;„,r, oniias Ori$ whi n ?u; utanud3r(s anc.1 ort:,irrt. C ad~tecluacy t,'d' do :4"1 Additions, dcVejohs or this (:iitte «c;,'1;:n6. t! resulaznittzii of. Final aca;2c)11' oil;: , !, IIV lin in Red Leder 'e i1;,vvod by The TuioN11.cI Fire "�I;Ifi'ii t' blil:i"• cu! rrlt City ;ia qi,}I:lseci; to (";:I°('i»rfi; Lind (St;11i i;iGIIS of. pit L1pted The (e:.ponsiblii . tor the lmtgY, v0:11 the deli ei;er. c;vi°,ala; 1,s t Y tt'Ik :•4 drawir:5 after yyl.I'r{i:i Wii4Y3,LyA,i;,l►rtr tl I �h..�. t•i•+� :NY.��.11'�„\Ii��� o.t.v 11`i�Yprova1• �:f�lli, E7...a .. t.r;t riei ,i t,a ,;Ii c1 tnspection by The I u1:VVii% 1'ti 1"1"i;r` : i i.Ct ttOe ii.l, Al'-' TO 'd Dave Loescher w/ Allied fire and security (425)988-6500 14JKW9l.A FIRE DEPAFTMI * Please call: 575.4407 and give this Job No. and cAaet for shut, ":ttbA zl or r+ +N'.:.r,:ltion a0.z>rOvro1 M °vO 1: .0 A completed, signed, Tukwila Pre Department Pre-test Certificate Must be presented! to the Inspector prior to commencement of Acceptance Testing or 71'?y Fire Alarm and i7y tic:: �'�,r' Systems, F ilure of test will r'esutt. 1, In -ill.T �a.?Tl tee eld termination ; 4 the... PAID 'Tukwila • Fire WIJ 8 T : 60 6002- T Z-AOW Th accordanc As completed panel, The by the bac supervisio Also this i all audible s. existing b near future system as Note: the contractor' fitnotionall Thank you, Z0'd Abu -Bake Islamic center of Washington /09 document is a summary of the completed work at the above site in with the scope of work submitted previously. f 5/20/09 all of the work described in the previous scope of work has been d tested. This includes the installation, progranuning and testing of the fire xisting sprinkler equipment, all pull stations, 1 smoke above panel and 1 heat hallway. In addition to these We have also installed a smoke power module and a NAC panel supervision circuit for additional supervision. eludes the integration and testing of 4 duct detectors. And the verification of isual devices. All zones were tested and all signals were verified. pre alarm, test for details. This work was done in the understanding that the lding layout will change and therefore the system itself will be altered in the At this time we will submit a scope of work and drawings to update the ceded. V on site was removed some time ago and will be re -installed soon by the sprinkler company. At this time we will attach the existing circuit and test the valve. Dave Loescher w/ Allied Fire & security WV 6T:60 6002 -TZ -M J TUKWILA FIRE PREVENTION BUREAU ver Park East, Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206 -575 -4439— E -mail: tukfdprv@ci.tukwila,wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm Sys m is ready for Fire Department acceptance testing. Failm of test will. result in LL ti• . W testing andiddijogituaill . Contractor Is responsible for power for Final Acceptance Test with two-way communications. Permit # supplying ma Date / ). 1 i " Property Addr 5_1 4 I O1l Wi G in e-CC4c�nt.. ls�. City Name of Facili Occupied as Owner or Representative L 0.0 Installing Comp, ny Suite # Zip Code Phone # 791— R7 61 Installing Contr tor's Address City Installer's Nara Phone # C4z 5) qI.S $ -(PRINT) _11e' License and/or ertificate General Contra Electrical Contr'ctor FACP Equiprne't Manufacturer „ (16, ,_ , — Model # 074ta GI V This system haseen stalled, pre -tested and operates in accordance with the standards listed below and- was inspected b On (date) C all that b ply: NFPA r 2, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 FPA ►0, National Electrical Code, Article 760 Manufacturer's Instructions Manucturer's Inatructions Other specify) .� Tukwi a City Ordinance Numbers 2050, 2051 UL Central Sta on Monitor SIGNED System Firmw e: Install version 7e De Checksum Date Initial rogram Installation Revisions and I easons —• �r_. J u .A 'O. Programmed b4 vidmIke and includes the devices listed.on back. System is monitored by Au i eJ, sec'() Date Date � C/C 20"d o�sr.;gd Wt' 61:60 6002—TZ—ht'W Zone Programming Report for Attn: Dave L - Allied Seattle ASU-Dokr hslan k.C.nt.r of WA 1.4101 Tvkwu« Intu noYanel Blvd TukwAlA King Washington 0111611 Customer Type: Conmerzisl Mallen Alllad Rra 8 Sam ely.Soa16A AREAS Number,Descri tion�p : 1 Common Am ON; Mon TO,: No OIC Monitoring Leat CVC Signal Recd: RA,1766 $#e Not Yet Commissioned Police Del: Remote Rent None TrrnwMCNrNo; Zona Programming 1 Signalling Type: Radlonlas 6800 Patin Enable Date: 6/19/2008 Connect Data: Zone Area 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 18 1 14 1 16 1 16 1 17 1 18 1 19 1 20 1 Pasonption Beck Hall Hent Ball Supervisory Smoke Power Supervisor Panel Smoke Waterflow OS & Y Temper Piv Temper NE Pullst.tion North Central Duct Deltic NW Back Pullstatlon Center Back PuHetation SE Pulsititbn Bost PuUrtrttinn South Central Dud Deltic West Rear Duct Detector Central Duct Detector Activat4un EVAN Fins General Supervisory General Supervisory Fire Waterflow Temper Tamper Pull Station Fire Pull Station Pull Station Pull Station Pull Station Fire Fire Fire Stene ID: 80175/6 Renewer ID: 14 Termination Date: Reston) Event Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Restore Relltore Is Ilex iteomni Minted an Awl the 170 'd Page 10/t Wb 02:60 6002—T —. I4 -.: arm,. P•A, ABL14ekr ilium ic Ce 14101 Tukwila Internet' Tukwila King WeshInUton 1181811 Wed 5!2012009 Wed 612012000 Wad 6/20/2000 Wed 5120/2009 Wed 5/20/2009 Wed 8/201200010 Wid 6100/2000 10 Wed 5/20/200010 Wed 5120/200910 Wad 6/201200610 Wed 61201009 10 Wed 5/20/200910 Wad 5120120.09 10 W.d 6/201200010 Wed 5/20/200910 Wad 5/20/200910 Wed 5/20/200910 Wad s/20/2009 10 Wed 5/20/200910 Wed 5/20/200910 Wad 6/20/200910 W.d 6/201200010 Wed 5/20/200910 Wed 5/200/200910 Wed 6/20/200910 Wed 6/20//00910 Wed 51201200910 Wed 5/20/200910 Wad 6120/200010 Wed 612012000 10 Wed 5/20/200010 Wed 6/201100910 Wed 6/201200910 Wed 5/20/2009 10 Wed 5120/200910 Wed 5/20/200910 Wad 5/501200910 r of WA rail Blvd 10: 1:17AM 10 :51AM 10 4:54AM 10 0:39AM 1 i 8:42AM :43AM :45AM 7:S5AM 5:01AM LOAM 9:02AM 9:03AM 9:65AM :68AM 2t08AM 2t09AM 4:09AM 4:10AM 8:S1AM 8:54AM 0:16AM 9:21AM 0:55AM 2:10AM 2:12AM 5:25AM $t29AM 8:15AM 7:12AM 7:16AM 9:41AM 9:46AM 1:00AM 1:03AM :00AM 2:12AM !I4:42AM Ar,HnnA commit P PM S0'd All Events Report Report weir•'20V2000 to 520/2009 RA,1758 6 Fire Trouble 5 Fire 5 Restore 7 Fire Trouble T Restore 7 Fire Trouble 7 Restore 7 Fire Trouble 7 Restore 1 Fire 9 Rvehor. Restore Restore Restore 9 Fire 0 Restore 10 Fire Troubl. 10 Reit rY 11 Fire Trouble 11 Restore 12 Fire 12 Restore 13 Mlsain0 Fin Supv. 13 Restore Restore 13 Fire Restore 13 Reitare 14 Fire 14 Restore 15 Fire 16 Restore 10 Fire 10 Restore 17 Fire 17 Rastora 18 Fire K ■ Knyf 11.r Crew ,$ ■ Slay A d Siktedil Adkur, F • Fir*, G ' Can Manny, 1.1ruNA# 4 M • Mediae! Alnrm Center Inc. 1.800.752.2490 Wks 02:60 6002—TZ—AVW All Hvw r$ RI OO kn AIAI IM too. GaAs 01 WA prirdInl rin t Ik 9 Wad 5/2012009 10:3 :01 A M Wad 6130/0009 10:2 :30AM W.d 612012000 10:2 :57AM W50 51201200910:34:00AM 16 15 20 Fire Fir. Restore ReetOre Adam's Lagend: P m Polies, K • KeyhnMEGm, S • Sift, A • Spelniiel AMON+, F ■ R., C m QM Ag?"ay, 1 ■ lnsMile , M $ AMENS Alarm Center Inc, 1400452.2490 90'd ✓'r1�109019 Wk! TZ:60 6002—TZ—AVW Lo -d EQUIPMENT 1INSTALLED AND TESTED: Control Panel Manual Statio Smoke Detect Heat Detector Duct Detecto AN Devices Audio Device Visual Device Auto Door Rel Trouble Indic Batteries Readi Generator . HVAC Control Fire Alartn.'Dia Monitored by Annunciator jofj_ of ,5 of 1 of A al of.0- of ia ofia ase of of gs Battery of of r .of Make/Model Make/Model Make/Model Make/Model Pod, 0741 1 GUS 'LC 'eQaiLS (DO Make/Model Ste6✓1 5en,53 f Make/Model 1,4 -EL D ti"t - a 4 - L S ,N' Make/Model 04 tai4,1% \ Make/Model 1tJ 11t evnC vtak-4;o Make/Model M /Model AA_ 4 Saes dwref AC. Full Load Make/Model Make/Model Make/Model MSF �owcC t3.9 Peel $Hoge f Charge i . I• pk4e) CI Sprinkler Water Flow S Valve Tamper. F'IV Elec. Alartrl':le Automatic time Do you meet au Yes No Test of alarm S Test Witnessed Cornments: 1.0f± Make/Model ystem. (Fire Alarm connections only) 't-- of j_,_ Make/Model{` . Y S R - F of Make/Model efi (Q„ $, of Make/Model vh of Make/Model slay of Water Flow Alarm 4.ciak go, 9Oseconds, None Installed ible/visible requirements of W C 51-20, IFC SEC 907., and/or NPPA 72 Chapter6? ffub;4ecct + CLAie) tem on emergency power, satisfactory? Yes No Y ,4( ALkeNpoei Title Date • 5/1q/6.5 5iV le 4. 1).t. spr uo k lir -1 ',►A .a eddins\Fire Alarm rtiflcate.doc Itevlged; 10/28/04 TFD Fp Form #110 Wk! TZ:60 600Z-TZ-AtiW SCOPE OF WORK Islamic Community center 14101 Tukwila International blvd. 5/12/09 FILE This document is intended to describe the scope of work and parts related to the repair of the fire system at the Islamic community center located at 14101 Tukwila International blvd. We (Allied Fire & Security) Intend to repair the fire system at the above location by replacing the circuit board at the community center with a like panel UL listed for fire. This panel is a Bosch D7412GV2 fire panel. After replacing the panel we will locate a smoke detector above the fire panel, attach the NAC circuits and connect the existing sprinkler monitoring equipment to the panel. Also we will be reinstalling a Radionics D1256 fire keypad at the entrance of the building for control. After doing this we will test the fire system to verify operation. After the building improvements have finished we will at that time provide another scope of work for updating the horn circuits and anything else that may need to be brung up to code after the new building layout is finished. Without Comments 0 Asiic:vdinRed O Per Attached Letter These plans have I- r'Ve'med by The Tukwila Fire Prevention Buretio, . nrn,d:rice with current City standards. Acte- �uoject to errors and omissions which .Lhorize violations of adopted standards and crc.. • --ccs. The responsibility for the adequacy of desir : E s i:otztly with the designer. Additions, deletic,.s or revisions to these drawings after this date wit void tnss c -7_:e,tance and will require a resubmlttai of ;Jr subsequent approval. Final accepr�n4 .° ,s'.: rc.id test and inspection by The Tukwila hie _ ..-t Baa. Date: –13— 0i Dave Loescher w/ Allied fire and security (425)988-6500 1UKWILA FIRE DEPART:. Please call: 575.440 and give this job No. 0 - F -07.? and exact address for shut; Down or restoration approve: NOTICE 1. completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testino. r Tukwila Fire , ' 7C • # 1 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Abu-Bakr Islamic Center 14101 Tukwila Intl BI Permit No.: 09-S-054 Date: April 10, 2009 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2007 Edition. X X X OFIRE SPRINKLER PLAN it NTS CONSTRUCTION NOTES: 1. ALL WORK PER NEPA 13 2013 2. EXISTING SYSTEM IS A WET SYSTEM IN A FULLY PROTECTED, HEATED EXISTING BUILDING. 3. WORK CONSISTS OF LOWERING 5 EXISTING SPRINKLERS SHOWN TO -LEVEL OF NEW CEILING. ACCEPTED Without Comments ❑ As Noted in Reel ❑ Pei The Attached Letter —5 These plans have Prevention 1Bure__.. standards.r omissions - s anddar ca, adec .Hae), • Additio' . thisdac. resubrni z - Final accept The Tukwila F1r° k4 'eau. viewed by The Tukwila Fire -.r.-)rmanre vflti.l current City t :, errors and '!olationv of adopted esuu'SibEiity for the ,.r<, i' =C: Jesleiler. 7rCiwirN.gj: after - a :� � >. E MtpprovaL T,eIc test and Inspection by Date: 3' l "/ 7 t': S 'TUKWILA FIRE DEPARTMENT Fie isc cal; 206-575-4407 -end give this Fare Permit No. ��- 3-0L/3 and exact adc;.ess for shut- down hutdown or mon approval. PAID MAR -8 2017 TUKWILAFIRE 3ig203 ■ ■ WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS Michael Todd Hallengren 7223-0107-C Levek3- Emerald Fire, L.L.C. EMERAFL980M HANGER NOTES 1. HANGERS SHAD. BE SAMMY SCREW ROD AND RING 2. TRAPEZE HANGERS SHALL BE UNISTRUT, UNISTRUT NUT. ROD AND RING. 3. ALL HANGERS PER NEPA 13. GENERAL NOTES 1. ALL MASK AND EQUIPMENT TO BE NEW AIC UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER 3. PIPE HANGERS AND MLTHOO OF HANGING TO BE IN ACCORDANCE WM1 NEPA PAMPHLET #13. 4. EARTHQUAKE BRACING AND JOINING OF PIPE AND FITTINGS SHALL OE IN ACCORDANCE WITH NEPA PAMPHLET X13. 5. OWNER TO PROVIDE A MINONM OF 40. F TO PREVENT WATER IN PIPES FROM FREEZING 01 AREAS PROTEL9ED BY A VET PIPE SPRINGER SYSTEM. 6. STRUCTURAL ADEDUACY OF THE BUILDING 10 SUPPORT THE SPRINKLER PIPING IS INE RESPONSIBILITY OF THE GWII1FR ANO OR HIS STRUCTURAL REPRESENTATIVES. Sprinklers Used ABU-BAKR T.I. sYM SPRROeWR ORME SRL TYPE & 09851 DUAN TEMP 14101 INTERNATIONAL BLVD TUKWILA, WA 0 TYCO � fL sag REC mow PENDENT 5 155 5.6 EMERALD FIRE FIRE SPRINKLER SPECIAUSTS 11021 GRAINER GD. KP.GL GIG HARBOR WA, 98329 857-2056 EMERAF15B061R TOTAL 5 DATE REM DRAWN: MN/AD 10F1 t. 4. -rt. FA -cc npre..47-- 11019 fP L_l2 rA-t,P 5Lc. Iu r�/ , PL-_ cP 101 rete- - cPS Aix -A 4_2 ►1A # +r Icy H rNA STUDY 2 144 SF VENT TO OUTSIDE (50 CFM) • 0 STU D_YJ 94 $,F r�o ‘AgoUgSEX 5'. -1- rt -es afi-r_jk. 3 - --- I�� y t ('LR VENT TO 011.:SIDE •- 125 Cr -1v1 EA.,) \-1) 5 111 SF C EXIST. BOILER 62 SE C \ITN\ M_�EIJj 267 SF HALL 573 SF DRIN1'G F NTN F. ASH HALL 83SF fz� Of C_. --ADMIN 190 SF T-' STUDL X154 SF STUDY._4 124 SF VENT TO 1UTSIDE r0 CFM) GiDRINK'G e FNTN OFC.-ADMUI 170 SF r>r STUDY 8 229 SF STUD 18 S 747 STUD 188 SF \ - - -� (50---�i) VENT '"10 OUTSIDE COP' Ur- 1 3 SF COMM. SVC, 1,588 SF OCCU:106 MULTI .rd. PRAY 1,763/S r 7 / OCCU:2 2 799 - NEI NAY AREA l/ i .. XAY/WOSHIP ,x,830 SF - 1 / 1;UCCU:E/3 I'4ET PRAY AREA e I a -7s d' - 82 SI* t 4 OF! -IMAM i- 61 SF 1 FLOOR PLA1 n SCALE I/ -1 U r8N Tice_ otlts•Ae G��� l MANUFACTURE MODEL DESCRIPTION SYMBOL SILENT KNIGHT .11 -?-5 FIRE PANEL I OcCP I SILENT KNIGHT SD500-APS PHOTO SMOKE e SILENT KNIGHT FSDA PULL STATION SILENT KNIGHT SD500-MIM MONITOR MODULE rn (1` GENTEX E GCS CEILING MOUNT STROBE GENTEX WGEC OUTDOOR HORN/STROBE oi GENTEX HS/ST WALL MOUNT HORN/STROBE STROBE (2E) 13 SILENT KNIGHT 5196 POWER SUPPLY (-LF 5 1 SILENT KNIGHT 5,8608 REMOTE ENUNCIATOR iNnne.. 1 WATERFLOW [ XI\ PIV DUCT DETECTOR /A` "SCOPE OF•WORK" INSTALL AN AUTQQMATIC PIR -E ALARM SYSTEM IN A ALL WIRE TO BE FPLR:Mii; 18AWG, 16AWG FOR NAC CIRCUITS. ALL STROBES TO BE AT 80" ON BOTTOM, HORNS TO BE 75 ,Di3 MINIMUM THROUGHOUT. ALL PULL STATIONS AT r 48" ON TOP. MONITORING VIA UL LISTED CENTER STATION. A FULL SERVICE AGREEMENT IS IN PLACE TO ASSURE PROPER TESTING AND MAINTENANCE PER NFPA 72 STANDARDS. ALL WORK TO BE PERFORMED IN WOF'•.<MAN LIKE FASHION. INSTALLATION SHALL :MEET NFPA 72, UBC, UFC, WAC, IFC AND ANY 'LOCAL AHJ CODES. A FULL PRE-TEST SHALL BE; COMPLETED PRIOR TO CALLING AHJ FOR FINAL ACCEP TANCE TEST. I- I 1730 DRAWN SYEPL"021fi1L` CONT#F*fi PL021 LI#CATS SEATTLE !IRE !'` .PT 4'SCP-O;•9955 NICET#4.400' 337 CFPS#l4Ta F PEiROM RE P t tYI BAT Fire Protection, Inc, GI ON ROAD, EVERETT, WA 98204 (1) • c• Cdsl /k3 -770 ce_sun0 Liu DEO itA-T-E0 ISM Me 0 rr's Fire Protection, Inc 1730 GIBSON ROAD EVERE:TT, WA 98204 OM s ®d=9800 or S00-881-1125(Phone) 426.-1V4546(Flax) it©lTepro 40* 4#•42, NFPA® OOp8 05tfi' 4, tal 111 0 CFPS® *1473 L. Cq Ts, 0411 OF/ 44to 9/5 $ Q 0 shiNG. 00_x_00 re v, re N a + C C %-}.r.,1 - Po,ti� gGtd��essgs, I• - Zns .11 bregker 114hLU' c' etv-p o d`J c.44 A cir& 4 bora ker. ►v•e, dR,f. kigwe key Lox, ,,,. —�Ms1�11 ft, L.. E'. 0. 's .�Gkavc. ce;I; c e od l\t" -,s ACCEPTED D Without Comments f As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is suttect to errors and amissions-which drs-r t authtrizeviciations of adopted standards and ordinances. Toe responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and Inspection by The Tukwila fire Prevention Bureau. Date: & r `(O 9 ,y: 40",,01 PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 FIRE ALARM ItakientA FIRE DEPART1116N1 Please call: 575.4407 and give this job No. -F- /23 and exact address for shut. Iowa or restoration An rnvpl, NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must -be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result a Re -inspection Fee and termination of the testing. PAID AUG 11 200944-:4741 Tukwila Fire k" NWA PROJECT N0. 301-305 w DRAWN BY ,CHK BY1 YK DATE 9/18/2008 SCALE AS NOTED TITLE OUTLET PLAN FLOOR PLAN NUMBER FA -1 ENT TO OUTSIDE 125 CFM EA) UNISEX 53 EXIST. BOILER 62 SF HALL 573 SF DRINK'G FNTN UT IL. 15 SF I II 0111W111. 111101116. SII VENT TO UTSIJE �0 CFM) DRINK '0 FNTN STUDY 8 BATI-i, 8)1 53 S VENT TO D112 OUTSIDE (50 CFM) VENT TO KRTCH. (BREAK) ®OUTSIDE 260F (100 ,;,FM) MANUFACTURE SILENT KNIGHT 9ODEL DESCRIPTION SYMBOL 5700 FIRE PANEL SILENT KNIGHT SD500-APS PHOTO SMOKE SILENT KNIGHT PSDA PULL STATION SILENT KNIGHT SD500-MIM MONITOR MODULE GENTEX GCS rek CEILING MOUNT STROBE GENTEX WGEC GENTEX OUTDOOR HORN/STROBE HS/ST WALL MOUNT HORN/STROBE STROBE SILENT KNIGHT SILENT KNIGHT WATERFLOW PIV DUCT DETECTOR "SCOPE OF'WORK" FNSTALL AN AUTQMATIC FIRE ALARM S1STEM IN A fut\'( SP..,n�Lfc� (— ALL WIRE TO BE FPLR-MIN 18AWG, 16AWG FOR NAC CIRCUITS. ALL STROBES 10 BE AT 80" ON BOTTOM, HORNS TO BE 75 DB MINIMUM THROUGHOUT. ALL PULL STATIONS AT 48° ON TOP. MONITORING VIA UL LISTED CENTER STATION. A FULL SERVICE AGREEMENT IS IN PLACE TO ASSURE PROPER TESTING AND MAINTENANCE pefR NFPA 72 STANDARDS. ALL WORK TO BE PERFORMED WOF{MAN LIKE FASHION. INSTALLATION SHALL i i1EET NFPA 72. UBC, UFC, WAC, IFC AND ANY 1L_OCAL AHJ CODES. A FULL PRE-TEST SHALL BE COMPLETED PRIOR TO CALLING AHJ FOR FINAL ACCEPTANCE TEST. 5196 POWER SUPPLY 5860R 5 1 REMOTE ENUNCIATOR n 1730 GI DRAWN BY CONT#FIREPL*021 N LI#CATS*RL022CG SEATTLE FIRE DEPT# CP -C-9955 NICET#4 —M3t; 3.37 CFPS#1473 PROPER IY_i E �rat'� LI ilI OAM ' .S R� FP/ Fire Protection, Inc. ON ROAD, EVE��A 98204 C44. STUDY 6 188 SF /0\• c) SIAL 0 I ® brnekete couill. GIrte..r a�, ded;rc,Ljt (4 �;rcu� (2)s�1(e4L.E.SCCc rai p,811B Fire Protection, Inc 1730 GI :SON ROAD EVERETt WA 98204 OM f 90-9600 of EO0-681-1125(Phone) 426-W-4546(Fox) x) i1/4py1.C,grs 0- -a m (11) (t)Po4144- 4ddic04Ji LI -I ret'' yeti( 4d sh#ro. -Cl vc Jerk Ki key So,C. GIB D10 QQMI. SVG 1,588 SF OCCU:106 i5 S x‘o Ito OED iC4TEO %SIL (,--° () V (3) CZE 1\D FILE �a OFC 4 208 SF (7) r� F4CP 55.15 r i f -t FSG' FLOOR PLAN SCALE 1/8"=1'---0" ACCEPTED p Without Comments j As Noted in Red o Per The Attached Letter !-„se plans have been reviewed by The Tukwila Fire --- r evention Bureau for conformance with current City randards. Acceptance is subject to errors and -mission -s which -do not authorize violations of adopted tandards and ordinances. The responsibility for the ,adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: Yd `/ -40 CI By: PROJECT TITLE/OWNER ABU-BAKR ISLAMIC CENTER OF WA 14101 TUKWILA INTERNATIONAL BLVD TUKWILA, WA 98168 CONTACT: MR. JALALYAR C: (206) 799-1379 FIRE ALARM 11.114WitA F#RE i3EPPR194411 Please call: 575.4407 and give this Job No. 0 9 F and xact address for shut. own or restoration avaroval NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. - Failure of test will result in a Re -inspection Fee and termination of the testing, PAID AUG 1 1 2009 Tukwila Fire ),18W0 NWA NWA PROJECT NO. 301-305 DRAWN BY CHK BY YK DATE SCALE TITLE 9/18/2008 AS NOTED OUTLET PLAN NUMBER FLOOR PLAN FA -1 7ESERVED 1 1 t4, O FICE ONE Iwo CN1' \ 5MTILLANCE N i IAi.L MARC? CEILING MEN' 5 HP CEILING WOMEN' 5 NAIL CEILING 1291 OFFICE E f o FICE TWO FOOD PREP SCLLLAIN H-3-1 Li 128 190' FIX TEM 190' FIX TEMP EOLR PT -22 EOLR PT -13 H-3-2 I; u I; '1 u CA5NIER - _---jf------- Wr' H-1-7 EOLR HOR -1 ij BAR T H-1-4 PAR ELI I 190' FIX TEMP 190• FIX TEM (HD'/ Ktl"aN PROP CELING EOLR PT -24 1 '(1D, 190' r2 4� L__J FIX TEMP H-2-6Sri t' 30 `HD, CARP ROOM PROP CEILING ;HD` EOLR PT -16 \ \HD, LT 6J ;HD) L 1 H-2-7 L OLtiCE t3AR EOLR PT -27 25 PINING ROOM H-3-4 H-1--5 PWR SUPV SMOKE "8" EOLR PT -25 EOLR HORN -1 LIQ 5102 If H-3-6 EOLR PT -15 PWR SUPV SMOKE "A" H-1-6 SEI EOLR HORN -2 H-2-8 EOLR PT -30 PWR SUPV SMOKE "C" H-3-5 1 GENERAL NOTES EOL DATA BUS "A" �L- Ell 21 CLUI3-ftOOR PL NMRE ALAM 5CAI G: I/8" -i'_0" LEGEND EOL DATA BUS "C" r ROOF TRUSS (TYP ) FIRE ALARM ZONES i GENERAL SYSTEM I NFDRMATI ON _ 1 SYSTEM INSTALLED PER 1 996 NEC, ARTICLE 760, AND NFPA 72 2 SYSTEM I S CENTRAL STATION TYPE 3 SYSTEM IS OPEN WI RE USI NG FPL RATED CABLE EXCEPT I N LOCATI ONS WHERE CONDUIT I S REQUI RED PER NEC 760 4 SYSTEM I S ADDRESSABLE POI NTS, POI NTS 1 -8 ARE HARDWI RED TO FACP, POI NTS 9-48 ARE I NTER- FACED TO FACP VIA 2 CONDUCTOR SHLD DATA BUS EACH PDI NT HAS A 6 DI GIT ADDRESS, SYS I S DIGITAL NOT ANALOG EACH POINT IS REPORTED 8. ANNUNCIATED BY PREPROGRAMMED POI NT TEXT 5 BATTERY CALC'S ARE PROVIDED DN SHT FA -2 6 OFF-PREMI SE SIGNALING I S VIA DACT TO A LISTED CENTRAL {STATION, FA SYS I NI TI ATI NG & NAC CI RCUI TS ARE CLASS B GENERAL SYSTEM DESCRIPTION ADDRESSABLE, PROGRAMMABLE, 48 ALARM POINTS 3 ON BOARD RELAYS, 125 OFF BOARD RELAYS, 2 CON- TROL KEYPAD, DUAL PHONE LINE SWITCHER MODULE, 1 BELL SUPERVISION MODULE 22 OFF BOARD POINT INTERFACE MODULES 12 VDC OPER. NAC CONSISTS OF 16 WHEELOCK MT-24-_SM-VFR HORN/STROBES, 6 RS 241575W -FR STROBES ALL 24 VDC 15/75C POWER PROVI DED BY 1 SI LENT KNI GHT 5395 HORN POWER SUPPLY, 4 EA _1 5 AMP CI RCUI TS AVAILABLE SMOKE DETECTOR POWER IS PROVIDED BY 1 ALTRONIX UL4000LX-R 24 VDC POWER SUPPLY FACP, FACP ON 8. OFT BOARD MODULES, HORN/STROBES, STROBES, HORN POWER SUPPLIES, & AUX SMOKE POWER SUPPLY ARE UL LISTED FOR THE APPLICATION AND ARE INSTALLED PER MANUF RECOMMENDATIONS AND REQUIREMENTS CDNTR. DATA t A ACCEPTED Without Comments As Noted la Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prc "antion Bweau for conformance with current city standards Acceptance is subject to errors and omissions which do net authonze violations of adopted standards and ordinances The rasporsihil, ) for the aaequacy cf design rests totally vain the clas,..gner Additions, deletions or revisions to the=se drawings after this data r,III vod this acceptance and will require a resubmittal of revised drawings for subsequent approval Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau Date. zt 11 `?1`'‘ By i J FA EQUIP SCHEDULE 1. NOTIFICATION CIRCUITS 16 AWG, STROBE CIRCUITED ON SAME CIRCUIT AS HORN. 2. INITIATING CIRCUIT ALARM LOOPS 18 AWG. 3. SYSTEM DATA BUS 18/4 AWG TWISTED SHIELDED, LOWER CAPACITANCE SERIES. RED, DATA BUS POS., BLACK, DATA BUS NEG., GREEN AND WHITE, SPARE PAIR. SPLICE SPARE PAIR AT EACH POPIT. 4. ALL FA CABLE FPL RATED, ALL FA CIRCUITS POWER LIMITED. 5. ALL FA SYS WIRE/CABLE TO BE OPEN WIRED. CONDUIT WHERE REQUIRED BY NEC. 6. DEVICES MOUNTED ON DROP CEILING TILES TO BE SUPPORTED WITH TEE BAR HANGERS. 7. ALL HORN/STROBES AND STROBES MOUNTED AT 80" A.F.F., IF NO AOJACEN,T WALL SURFACE OR SUPPORT COL, MOUNT ON CEILING SOFFET, 6" FROM CEILING. MOUNT MAN STATIONS 48" A.F.F. TO CTR OF MECH. 8. HORN/STROBES AND STROBES TO MEET NFPA 72 REQUIREMENTS. 9. RADIONICS POPIT MODULES TO MOUNT IN DEVICE BACK BOX, OR IN J -BOX ADJACENT TO DEVICE. - 10. ALL INITIATING DEVICES EOLR AT DEVICE UNLESS INDICATED OTHERWISE. 11. MOUNT RAD 1257 ANNUNCIATOR 60" FROM FINISHED FLOOR. 12. POPIT=POINT OF PROTECTION INTERFACE TERMINAL. 13. TAG CB HANDLE RED AT SERV PANEL WHERE SYS 120VAC IS DERIVED, NOTE ON SERV PANEL DIR "FA SYSTEM, DO NOT TRIP". 14. HORN PWR & AUX PWR CONDITION MONITORING POPITS LOCATED IN FACP. 15. INIT DEVICE EOLR 33K OHM, HORN/STROBE AND STROBE EOLR 4,9 KOHM, HORN TRIGGER EOLR 560 OHM, PNL HARDWIRED POINTS (1 THRU 8) EOLR 1 KOHM. 16. CEILINGS ARE OPEN TO ROOF TRUSSES EXCEPT WHERE CALLED OUT OTHERWISE. FIRE ALARM CONTROL ION HORN/STROBE, WALL MOUNTED ON STROBE, WALL MOUNTED W P.10741HORN/STROBE, W/ ENVIRONMENTAL HSG FA SYS ANNUNCIATOR 1E42 ANN [98 RADIONICS POPIT, / IS POINT ADDRESS OSYS J—BOX $D SMOKE DETECTOR L] HEAT DETECTOR HEAT DETECTOR MANUAL FA STATION —�— FPL RTO 18/4 SHLD --a- FPL RTD 16/2 ---}}-- FPL RTD 18/2 - - -H-- FPL RTO 18/2 ABOVE DROP CEILING PT -7 AUX POWER BATT & AC PWR SUPV PT -8 BELL SUPV HORN A PT -9 SURVEILLANCE ROOM SMOKE DET PT -10 HARD COUNT ROOM SMOKE DET PT -11 OFFICE ONE SMOKE DET PT -12 OFFICE ONE MAN FA STATION PT -13 OFFICE TWO SMOKE DET PT -14 CASHIER CAGE SMOKE DET PT -1 5 GAMING ROOM SMOKE DET PT -16 GAMING ROOM ABOVE CEILING HEAT DET PT -17 GAMING ROOM MAN FA STATION PT -18 REAR EXIT MAN FA STATION PT -19 OFFICE THREE SMOKE DET PT -20 MEN'S ROOM HEAT DET PT -21 WOMEN'S ROOM HEAT DET PT -22 FOOD PREP HEAT DET PT -23 KITCHEN HEAT DET PT -24 KITCHEN ABOVE CEILING HEAT DET PT -25 DINING ROOM SMOKE DET PT -26 DINING MAN FA STATION PT -27 HALLWAY SMOKE DET PT -28 LOUNGE REAR EXIT SMOKE DET PT -29 LOUNGE REAR EXIT MAN FA STATION PT -30 LOUNGE SMOKE DET PT -31 LOUNGE FRONT EXIT MAN FA STATION TYPE OF FACILITY ADDRESS FA EQUIP MANUF SYS CDNTR CENTRAL STATION RETAIL STORE 21 CLUB 14101 PAC HIWAY SO TUKWILA, WA RADIONICS 1800 ABBOTT ST SALI NAS, CA 93901 1-800-538-5807 RELIABLE SERVICES POB 1298 EVERETT, WA 98201 1 -425-353-551 2 ALARM CENTRAL SERVICE P 0 BOX 1761 BEAVERTON, OR 97075 1-800-452-3555 1 RADIONICS 72t2BB FACP 2 RADIONICS 1256 COMMAND CENTER 1 RADIONICS D8125 POPEX MODULE 1 RADIONICS DI 92C BELL SUPV MODULE 22 RADI ONI CS 91 27T POPI T MODULE 1 RADIDNICS 08004 TRANS ENCL 1 RADIONICS D1 36 RELAY j_ 16 WHEELOCK HORN/STROBE MT-24-LSM-VFR 5 WHEELOCK STROBE RS241575W—FR 21 WHEELOCK IOBR BACKBOx 1 SILENT KNIGHT 5395 HORN POWER SUPPLY 1 ALTRONIX UL400ULX—R AUx POWER SUPPLY 6 A I P MANUAL FIRE ALARM STATION 30 ESL 449 PHOTO 4 WIRE SMOKE DET W/ BASE 8 CHEMTRON 135' RATE OF RISE HEAT DET 5 CHEMTRON 190' FIXED TEMP HEAT DET 8 YUASA 12 VDC, 7Ari BATTERY 1 YUASA la VDC, 18AH BATTERY TUKWILA FIRE DEPART Please call: 575-440Z and give this job No exact address for shut• n or restoration approval L'ta�l)5F C?i'ovh Ck ` "CDC A L 8Av1,e-e s MESA an do -W(rat S) t1c'v..;140 2� R.A.5\ >ce 0100-04. CAA Cs rayA 1 2 3 4 6 ( REVISIONS • BY DATE PLOTTED CAD FILE 1 D 0 � 0 v V $3 .1Q F -- (A / W 0 M L.L.. M 'e— oD 1� .J DATE 02/04/9? SCALE i/8"=1 -0" DRAWN 8Y PR NONNOHAN WORK ORDER / ???? J SHEET TITLE FIRE ALARM SYSTEM FLOOR PLAN FA -1 11:PFE°B2r8719::: 1s\k 101-k,1 1 3 4 NOTE' SHIELD TO BE CONTINUOUS TO LAST POPIT ON BUS TO POPEX FACP BACK RED MELD TO AUX SMK PWR - RACAO 65 CII. 27 POryT MOOV.E REO BLACK HORN POWER SUPPLY ESL 449 CS SMOKE DETECTOR t tt"w"i I- ESL 449 CS SMOit HTECTCR &ARV D'WER r—= I SMOKE DET CIRCUIT (TYPICAL) N.T.S. HORN / STROBE STROBE HORN / STROBE HORN/STROBE CIRCUIT (TYPICAL) (1)16/2 TYP. ALL SIG CIRCUITS (1) 18/4 RADIONICS 7212 FACP N.T.S. SIL KNIGHT 5395 HORN PWR SUPPLY • s:o Ea -ACA 4.7K OHM EOLR J FA SYS NOTIFICATION CIRCUIT RISER N.T.S. BRrM.4 EiRLirs ESL 449 CS SMOKE DETECTOR ALARMf FC.vER r - --- 33K OHIA EOLR +� HORN -1 SERV PNL 1 20A 2P RAD 0294 EOL POWER SUPV MODULE 1--RADIONICS D8004 TRANSFORMER ENCL f-18/2, 1/2" CONDUIT 1 RADIONICS 1 I 7212 FACP ALTRONIX AUX PWR I SUPPLY I SIL KNIGHT (5395 HORN PWR' I SUPPLY j I 12/2, 1/2" CONDUIT FA SYSTEM POWER RISER �i----- HORN -2 HORN -3 N.T.S. FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS BATTERY STANDBY CURRENT FACP MOTHERBOARD DUAL PHONE LINE MODULE 1 BELL SUPV MODULE 1 POPEX MODULE 22 POPIT MODULES 2 COMMAND CENTER TOTAL STANDBY CURRENT BATTERY ALARM CURRENT FACP MOTHERBOARD DUAL PHONE LINE MODULE 1 BELL SUPV. MODULE 1 POPEX MODULE 22 POPIT MODULE 2 COMMAND CENTERS TOTAL ALARM CURRENT TOTAL STANDBY CURRENT 0 414 AMPS X 24 HRS TOTAL ALARM CURRENT 1 100 AMPS X 0 084 HRS MINIMUM BATTERY CAPACITY REQUIRED DERATE FACTOR @ 1 1 BATTERY SIZE TO BE PROVIDED (NOTE RADIONICS CONTROL AT 12VDC, 2 EA 7 5 AH PARALLEL PROVIDE 14 AH AT 12VDC) 0 200 AMPS 0 014 AMPS 0.020 AMPS 0 048 AMPS 0 072 AMPS 0 060 AMPS 0 414 AMPS 0 400 AMPS 0 040 AMPS 0 060 AMPS 0 096 AMPS 0 144 AMPS 0 360 AMPS 1 100 AMPS 9 94 AMP HRS 0 095 AMP HRS 9 78 AMP HRS 10 76 AMP HRS 14 AMP HRS BATTS IN HORN, HORN/STROBE POWER SUPPLY BATTERY CALCULATIONS BATTERY STANDBY CURRENT PANEL MOTHERBOARD W/SUPV CURRENT TOTAL STANDBY CURRENT BATTERY ALARM CURRENT MAXIMUM AVAIL CURRENT TOTAL STANDBY CURRENT 0 225 AMPS X 24 HRS TOTAL ALARM CURRENT 6 000 AMPS X 0 084 HRS MINIMUM BATTERY CAPACITY REQUIRED DERATE FACTOR 2 1 1 BATTERY SI ZE TO BE PROVI DED NOTE 2 EA 12VDC BATT IN SERIES, 24 VDC 7 AH LOAD IS CALCULATED AT MAX CURRENT AVAILABLE 0 225 AMPS 0 225 AMPS 6 000 AMPS 5. 4 AMP HRS 0 50 AMP HRS 5 90 AMP HRS 6 50 AMP HRS 7 AMP HRS FA EQUIPMENT BACK BOX SCHEDULE 1 HORN/STROBE, FLUSH MOUNT -DEEP 4 SQ 2 HORN/STROBE, SURFACE MOUNT- RSS SUPPLIED BACK BOX 3 STROBE, FLUSH MOUNTED- SINGLE GANG BOX 4 STROBE, SURFACE MOUNTED- RSS SUPPLIED RED WIREMOLD BOX 5 SMOKE DETECTOR-4SQ W/ EXT RING 6 HEAT DETECTOR-4SQ W/ EXT RING 7 ANNUNCIATOR -SINGLE GANG 27 RADION1CS 7212 FACP 09 29 30 AUX POWER SUPPLY -SMOKE DETECTOR POWER BATTERY CALCULATIONS BATTERY STANDBY CURRENT PANEL MOTHERBOARD 3 POWER SUPV MODULE TOTAL STANDBY CUR1?ENT BATTERY ALARM CURRENT MAXIMUM AVAIL CURRENT TOTAL STANDBY CURRENT 0 260 AMPS X 24 HRS TOTAL ALARM CURRENT 4 000 AMPS X 0 084 HRS MINIMUM BATTERY CAPACITY REQUIRED DERATE FACTOR 2 1 1 BATTERY SIZE TO BE PROVIDED 0 100 AMPS 0 160 AMPS 0 260 AMPS 4 000 AMPS 6 0 AMP HRS 0 30 AMP HRS 6 30 AMP HRS 6 93 AMP HRS 7 AMP HRS NOTE 2 EA 12VDC BATT IN SERIES, 24 VDC 7 AH LOAD IS CALCULATED AT MAX CURRENT AVAILABLE 0 0 31 DATA BUS "C" AND SMK PWR "C" SHLD,(DATA BUS),(1)18/2(SMOKE POWER) --TYPICAL 20 21 22 23 24 25 SMK PWR EOL SUPV MOD HERE SD HO HO HD PO HD SD HO { HD 10 10 11 (2) 18/2 ALTRONIX AUX PWR SUPPLY 12 ANN ANN 13 0 0 0 18/4 TW SHLD (KP AT DINING ROOM 18/4 TW SHLD (KP MOUNTED ON PANEL FRONT) 14 EXIT DOOR) 15 16 26 DATA BUS "B" AND SMK PWR "8" 17 SMK PWR EOL SUPV MOD HERE DATA BUS "A" AND SMK PWR "A" SMK PWR EOL SUPV MOD HERE FA SYS INITIATING CIRCUIT RISER N.T.S. 1 1 2 1 � I a 1 5 I 6 REVISIONS BY N. DATE PLOTTED CAD FILE 1 .1 DATE 02/06/99 SCALE. AS INDICATED DRAWN BY. PRM WORK ORDER 1 6750 SHEET TITLE FA SYS RISERS & BATT CALL'S FA -2 J it I 1 � 2 3 4 5 6 + 12 VDC 7AH 16 5 VAC CLASS 11 TRANSF W/ RAD D8004 ENCL 6 6 + 12 VDC 7AH RAD 1256 COMMAND CTR PANEL KP ADDRESS # ONE REO YELLOW CREEN BLACK RAD 1256 ANNUNCIATOR e i2ADI0NICS 1)7212 16 5 VAC NauT • 6 5 VAC NoLT AUX POWER BATT NEC 8ATT POS RELAY A PCS 110 O RELAY 8 P05 110e RELAY C PCS II 0 COMMON • GROUND RN TO TCR 1 8.X TO 'ERM 0 Py (,.ACS( TO PRI PHIJACK TJ SEC PH JICK TO 'E_C0 e F OIN f ONE 0 z 2 0 POINT TWO POINT THREE z 0 0 0 POINT FC'UR j X O z v., ,!i z O 0 z • z z m O 0 0 9 0 ▪ C. C. J POINT E IC HT G 14 GGGGGGG G8(i_D KI 6 PCw:R PDS ® IN LAA S1.5 A 0 i I G 1 CAA 6„5 8 17-&-7 ! 1 1 ' COMMON (; `J I 1,61 3;6.1 I Z:,NEx C.1- T Z:,1.Ex IN 1 L" -\{k CUT 2 ZCNEX IN 2 ZCNEx ZCNEX COMMON 6) 010�'G/'101Imo"0 0A Ct s iC 1—'1— RN —'1 AC PCW=R ,EO PRIMARY FA LEC SECONDARY FA LED CCMMGM1 CA" ONS rAn.�RL )) 1K OHM RESI STOR—� II F F0 N ° N RB RE.A ' 1 ; ' 2j NO /1 17 RED DINING RU " EL,O KP ADDRESS TWO GREEN BLACK RED REDCK BLACK RED BLACK DATA BUS " A' DATA BUS ' B' DATA BUS ' 0' t. 1-r (T �+r RAD DE 25 GGPEA AUX SMK PWR RESET INTERFACE RELAY A C C NC NO C NC ?ATT AC I1v AOTCNIX 400 1_,L)< AUX POWER SUPPL_" o 6 - + 12 VDC 7AH t PANEL-INITATING CONTROL NTS 6 0 - + 12 VDC 7AH PHASE NEUTRAL I C.,' A x -SMOKE POWER A B, & C LOW POPEX ( e RADIONICS D7212 1€ . VAC NPL, Et) VAC NPLT A k PCWEK BA N C BAT PDS R£.AY A P„S RE.AT 9 PCS REA CCMM„N 7 s Z O > x t p 2 -i Z eO Z v U Z O0 GCEzGGA C 1 OINI 1 h. 11T PCWLR PCS CAA8SA LATA GLS b 0011µ;r 20\EX OjT 20 4EX N 1 Z0 EXCJ1 ZONcx 11 . ZON_X PGW R PCS ZCNcx CCVMON 0192 '2E1_L SL.3V MCD ,LE z a 2 I 3 x 3 a PIP i u ALARM 1AIGCLA E POW1 12 IN z L L NY G ALARM C*A J o 6 12 VDC 7AH I4ORN #3 6 DEVICES MORN #2 8 DEVICES HORN #1 7 DEVICES 4 7 11 ORM COLA 6 0 12 VDC 7AH 47 K ORM EOLR 47 K ORM COL* BATT + BATT - SILENT KNIGHT 5395 HORN BOOSTER NEUTRAL GROUND PHASE 30 2® 1 e 516-1 M 516-2 MB rauLT _ 516-3 IRpCATORS 516-4 M BATT MD Abs SIG -4 SIG -3 SIG -2 SIG -1 INPUT -1I INPUT -2 4 5 6 7 8 9 10 11 12 113rn3 1414rn 15 16 17 000ZOZZZZ P3 560 OHM EOLR (RAD BELL SUPV ) CONTROL PANEL -NAC NTS 11 I 1 REVISIONS BY DATE PLOTTED CAD FILE i DATE 02/06/99 SCALE AS INDICATED ORAWN BY PRM WORK ORDER j 6750 SHEET TITLE FA SYS FACP SCHEMATIC FA -3 1 0 r f r NO GHgNyE A t% T.% 1 CS L .1 • / i • - — f G A 0 0 0 4 Ex/ST/N4, 0 0 r 0 0 0 I 192EA of &C/VG GENERAL NOTT.S 1 All material and equipment to be new and underwriters approved 2 Piping dimensions are end to end (D'-0 ) 3 Earthquake bracing shall be provided in accordance with NFPA pamphlet number 13 4 Pipe hangers and method of hanging to be in accordance with NFPA pamphlet number 13 5 Piping shall be accordance with pamphlet number 13 6 Joining of pipe and fittings, threaded and welded shall be in accordance with NFPA pamphlet 13 7 Owner to provide adequate heat to preve..nt water in pipes from freezzng in areas protected by a wet pipe sprinkler system 8 Structural adequancy of the building to support the sprinkler piping is the responszblzty of the owner andlor structural representatives SOUDWOOD NAM EARTH QUAKE BRACE FL 04/2 PL,git/ 1 - Lx/S T/A/c.j asp (s`TL'. Re.s.) ACCEPTED ❑ .;thy ?t Comments ❑ As la Red i .t,..Rti.l io`. Letter These pians have. The Tukwila Fire Prevention Bureau for c -carmance with current City standards. Accecto. i,4 I= :ct to errors and omissions which co NIek tir le violations of adopted standards and ordinances T''e responsibility for the adequacy of design r€_ : t5t.:14/ with the des'igner. Additions, deletions cr to triese drawings after this date will vo't2 e'd will require a resubmittal of for sJP:equent approval Final accepteicc is st...y.7.ct to f a d test and inspection by The Tukwilarira tr_3J Date: Li —i U -09 5, /—kA/N S 1 1 ruKXatLA FIRE DEPART t Please call: 575.4402 and give this job No. o 1- S - OS Ll and exact address for shut. aown or rastoratton apDrovt 4 NOTICE We!d stamps must be inspected before pipe is hung. Do not paint piping prier to hydrostatic test approv L LE COPY -- 7009 Tukwila l=ireis-0. WASH. STATE CONTRACTOR LIC #EMERAFL980MR HANGER LEGEND L WALL BRACKET APPROVING AGENCIES A B SAMMY SCREWS COACH SCREW ROD M MACHINE THREAD ROD SPRINKLER INFORMATION CANOPY INFORMATION N TOGGLE BOLT C BEAM CLAMP & RET TRAP 0 POWDER DRIVEN STUD SYMBOL • QUANTITY TEMP MFR MODEL GLolj� S?D. RES. K= S, e!o CL TYPE RIZg:CS(q FINISH cylzo/va" ORIF MFR MODEL D EYE ROD P CEILING FLANGE REVISIONS E KWIK BOLT R LONG STRAP FINISH &1. , Ct//la/'g F FLUSH SHELL G H J SIDE BEAM BRACKET (#58) STD SIDE BEAM BRACKET UNISTRUT & CLAMP s T SHORT CLIP TRAPEZE (SEE DETAIL) v W PIPE STAND WRAP-AROUND U -HOOK K U -BOLT x RISER CLAMP EMERALD FIRE, LLC 11021 CRAMER ROAD KPN GIG HARBOR, WASHINGTON 98329 (253) 857-2056 ,%L?/J-/9/VZ /SeRAI/G cg/v7-/e O, G✓,q, /4/0/ /N7 7e/t/r9T/a, t/, ,t�Gv4, TU/a,i// ?) w/.9, ,e/e, $ DRAWN BY DATE JOB NO. TOTAL 5, , /sort/ q/z /0 9 9�ss SHEET /- / F ti d 4 3 4 _e Vs i 4 x 1 f } a 1 t 1 ti 4 4 1 c C 7. - t t tr.'s? Y• DJ -.11i /i►,..) • fly 044.4 S 1`/1 Sr rela e exclusively to the - * ..e P', Inst Mice ra as as -cle'rrrnediji � • xi have ben Mad with and apprc- i'"9/ a enot to be construed as beanrg s -ar c .e cave has been exercised 4 to proper'/ It .4 rarer racy st al L_ P , �cr c -- by -' by tb try 4 raSP • .;" i .at V.1 `LJ 145s t1 Q 7. 9 3 3 3 a EKtS1'.414 ea../-Z10Jt, t 1 51 TE PLA til 1 t Sc..t4 tIL = / -o • 4 } a i r i . 1 1 r , • h R V 1 i E i i ' "` . .12 r 1 -•# by t . 1 } , Lag End Hangers • Hanger Rings UL Listed & FM Approved t Hanger Rods Comply with NFPA 13 t Machine Thread Rod Only ■ Finishes D Standard Components 0 All Galvanized Components 1--254mm Components 1 Spring Clip Ceiling Plate (optional, 2 Hanger Rod 3 Adjustable Hanger Ring 4 -WAY SWAY BRACE ATTACHMENT UL Load Rating 2015# SIZE 1"x 1", 1 1/4"x I", 1 1/4"x 1 1/4" MATERIAL Carbon Steel FINISH Plaut and Electro-Galvaruzed APPROVALS Underwriters Laboratories Listed BRACE PIPE SIZE A a i•xt• 212 33!r 1•X 1 114" 21N" 333 1 1/4 X 1 lie 2 1r2• 3 7/16 FUNCTION Bracing nsers and piping for seism! disturbances Location ofAFCON #079 requires that maxri ium distance of 3" from brace.: pipe be mamAC C E PT E D INSTALLATION K Extend brace pipes through parts ur_'1 contact r pass beyond the pivot bolt. Tighten set screws unnl set screw head contact bracket. Without Comments As Noted In Red 0 Per The Attached Letter ORDERING Part #, size and finish. Z) a.* fa.. as noCek. TUKWIIA FIRE DEPARTMENT Please call; 575.4402 end give this job No and exact address for shut) 1uwn or restoration approval. These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances The responsibility for the adequacy of design rests totally with the designer Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approvai Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau Date• 1 By 5(0 g4 r 4 3 a CROWN FIRE PROTECTION INCORPORATED PO 80X 12113 uU1 CREEK, vtet-saNCTD 93D82-0113 Ptt (20e) 461-7669 I -I 1t I la w t 1 • • _ • - t t 1 E • , t a f 1 l • • • ► r 1 , e 1 • } ..� A a. .'. DL r• .J.s n •c 1%1.17E1. M -n. Gw1. t v1 i.../%10 44 • 0 pr •. h o 0 0 0' q 0 f ,. { �. r /-rte r a • • a _�'� ? atr • 1 t LA Itt PI 00 *CI .'n\i ---1 -J o J ..J 1 -_-__ IDL M ti ^1 ry A K {, IN% OPi .1 / N. N .a ry : .h. n� '/y r. <n• '►� .it N a 11 • 7 d r t ?--- / () f —{ -----s —(i ----() / ( x t. �= ^t �'d ,rl "� . oma. $ .rF 4 /t )I /-tf l+ . 1'r'I sl .' 8.. -. $ O .y w 1 Y . ,1 1."�lf d 0 ti S 1 .! 11; 0 0 'Q '0 VA. '4 '0 '41 0'0N 0 • r I' 4* tJ ` i A V. f %ZcM•-rt. A1f1► 1. ,13/3oors tie Pu h. $ b£ct Ovex SPRItJKLER RANI • .• • • 1 t a • SCALE s•. t -o' 2— • • • K Ar -Art aA 164.1.1!.. 4JG 4.44 ✓.1./t W/&o sr •.JD tI1-• 1L r*MS 13tSr4..i tn- al Fast 13 Lel,+ rr A•6,. 13/7v•.MEr4A 1,1 a. •a t k APeAe,Jco - Ito 152 - .2 PP u4 P,Ps C4 oe• - GL•JE t0 D - Tia - 2 32 • 3 4 RISER SECTION M • • SCALE 3/8' r 1 —Q Ye 8E S...46...cc.) AS Su w.., 1u UWN4.cA DrT>i4. t.. Z blt •4 A T/.r rxs a 2iL- [AA cO D yua 1cL0a.. M . •• AA ,a) .7 s.00' T ►S,• �Lt L AA*to H1 .(/t444, C.,1- Pc►•P ISS t,r1s D,,� PnuQ Day H a s .e�-J..cL. r f4 15S 111 41. J a 1 J r a luw • • • • r 1 ACCEPTED EV Pm klae ralCH S'„aVEYINS titi3 F1. .SE t'le rcQutrernens of this Saire�J .,r s �1 c ares or dtt�ar ra !i w4p? ove1 ratesadAccas a'CPc -, 1 ancr octa 'icy st-own ieteor+ n i,. �i 31 a :Ce�'talice g co !ants relate exd usN&Y to the retat+ve ��` -yin fire insurance ra es as de ermined u Jar cLr nave Deer fled IYti1 and ale a a P rot to be construed as tear,- 1.-y r 3 c,.., has t;:;en axe C Sad t 17_ r rr • 1• 1 .. t -11(R , i — Cts c �� Cx /3//0... 24 9i Sr..tL - t9 ; 1 • CROWN FIRE PROTECTION INCORPORATED P 0 BOX 12113 WILL OC NA5{lHGTD4 93082--0113 PK (206) 481-2659 FL(,1Jc, ACES SI'v,ZTS BAZ /4101 ?AC /Ivy y S %UKW,LA , jiJp p M JUL 0 8 1g90 4 a v DAIS G 11 95 DRAW c -t SCALE N•rr, PIP t t { a T ! L/E kl PI P l FJC. E f: L o t.J IC A I S E b 7 A L. A2LA 4 E .c UP 4 f s 7 S-T-AciL - A tai 9> ALG '. l - ti Lag End Hangers • Hanger Rings UL Listed & FM Approved • Hanger Rods Comply with NFPA 13 ■ Machine Thread Rod Only • Finishes O Standard Components 0 All Galvanized Components FIG 58 1II11EADI-D SIDE BEAM BRACKET Sire Range 3/2' Aad pipe urn lir duel 4" Mdcrlad Carbo. S sd f.ncd.. Prettiest end .conooi:al backer .ted so support ptpkn kom soot( concr.sa or *reel beans features Unique deryn ails d r be easily *weeded bio bracket Offset dsslypt penis unlimited sal aJ►us1- rnent Cermet aawntln9 !role i 4 accept 31b- & I/2- lasiarsar bokt Per df PA Ali 1/2" duo 2 - rpm requires 3/8 leaner 2 1/2' 12,11 4 pipe wren 1/r farmer Apposed' Undenen 1n Labo.eb.es tired, Canadtu Under.erman Laboratories listed and Facsoq !karat f ngktuning Approved duough 4 PN Nat U L and F't t red rhe Flu 58 untiring 2 e l a.2' chive screwstf y ' 125) ills Laming method .os Wankel rote adequate for re oa 2" pia Ind arufa M .av eonjrwcIo. flniik run and ElcnaGalvanized Ordst Be figura nomxt and knish PATENT K/nDWa 0 MI SUE A an. SIZE t C 01 Of E e a —�Xlribr'—' aLPWT tea 100 11' 111110 4 2 31 3/r 1 1/8' 33/64" 11164" 7/l4- 1 1/3" 1 1/2- /`ioriS UESIL..l PL2 N F P A r3 a/2r7 /-1'2 Marto ALS (A L Pk f A.-, fl✓DnnJ. 7' PIP IAJL 70126.2 'zb n s .S-, wet_, /.., L/.ILJLLh bt:Ta,s_ Caw2 Ir M.J S INA.L i /55 2. i P H S I SS a I z. z LoC.Ar/a kJ 14 1" Components 1 Spring Clip Ceiling Plate (optional} 2 Hanger Rod 3 Adjustable Hanger Ring 1 .•254mm TYPICAL APPLICATIONS TOR TIG 58 THREADED SIDE BEAM BRACKET Shown llama f langing.p for 4' Pel. mill Lag Bok Ww'AR CLC s . Shown 'tete f 1angeng up so 2- PIp4rids ft1v4 Surat a 1 AJ r S f�J FILE rETLS ACL s ACCEP ED Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances The responsibility for the adequacy of design rests totally with the designer Additions deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval Final acceptance is subject to f eld test and inspection by The Tukwila Fire Prevention Bi. reau Date Y 5 .Ri..IFA CW RJ L.L fUKWILA FIRE DEPARTMENT Please call 575-4407 and give this job No 03 S and exact address for shut- down or restoration approval • CROWN FIRE PROTECTION INCORPORATED PO BOX 12113 MILL CREEK, WAS)IING10t1 98082-0113 PR (206} 481-7669 DYNASTY © PETE'S FLYING 14101 Pacific Highway S. Tukwila, WA 98168 A FETE AUG 16 2000 OS- (Oo °) DATE 8 /o ao I MDRAWN E a l SCALE AJ t 7113 I !or 1