The drawings affixed hereto have been
reviewed and accepted byc..the City of—
Tukwila Fire Dept. Additions, deletions
or revisions to these drawings after thi(,
date will void this acceptance and will
require a resubmittal of revised drawings.
Final acceptance is subject to field -
ins ;)n by a,ee resentative this
Oa BY:
57,--
CITY
v
CITY OF TUKWILA
575-4407
VIIMIIINARBOXICSIMIDENUMMIMMICESZEISIRMENIMIN
1
r
1Y\ re-‘ P c=fit. '` G.CQS
r-A�43
►�s
TUKWILA FIRE DEPARTMENT
Please call: 575-4407
and give this job
No. ?3— /r-0 5
and exact address for shut-
down or restoration approval.
MS
MS
Li"
rl
13a4}eri nc 5% en \- \s\ -._1:,4_11.933,2„..5,2,,a4.
B o.AN t T ‘ e 1 12, v o L7 ^l A NA " Y U 0. 5 G " WC) -1 1
S►len - kri1611"‘- tt 5 20 IA s-i-tAnAyt.y .02,0A
21-1 `,c- t3 ec.t0 2antl ( • ..t3
Current/ tical,.) Dt -et or
Tm-i-ce.t S -}ani, i�rruJ
ytcg,ai ortac) •fat- 21-1 bets
fI111Gc+a Slt !tel Loo c (1 -toms on\1).(1-1) = • 12414._,
m\no+e, : nc - olf c.urr n-1-
To+(.1 tarn H rata 2 .25
"l\Arno -%1)c)
d2*rs' 5 " \9,11.1-1 9r.%&" /N 12 1 %
At)Z-Aexhc . Scno1kp e.,Aor II RI1.6 2w,re. 2-400
1 -loco Whtel >:-I1'—el j -R
N0ccl V4.1.%-Fco(ADA) Wlnsfe t.11.. # EN -ELI -W M -24
SOI; &
p Ire, w►re S�x�1ea -{o vs�ll
FPI- w,re-,/S1gevel vn4 r '17'
7'ti\n\ T. Vu Thu T. OOo
t 3c11ct /21 / 23125 14w1 S.
Tukw,ta W A 4 1
SCALE: 3 "
to
DATE: Fos, az, 4 3
APPROVED BY:
DRAWN BY 2,..+
REVISED
Yn9ro.nn L 1e.c�-r1L 1 Inc.
.0- (ex 55214.
ec.ttle , v1/4111, ct btSS -0214
'-1to1- `3
V12- 1306
DRAWING NUMBER
18 X 24 PRINTED ON NO. 1000H CLEARPRINT •
LEGE\ 3
<WIRE SCHEDULE>
—Z—: 14 AWG 2 CONDUCTOR
—X—: 16 AWG 2 CONDUCTOR
<CANDELA RATE NOTE>
1. 75 CANDELA FOR HORN/STROBE
2. 30 CANDELA FOR STROBE
4 Rau, -,s hot k. CIa, c httniz q t I beat k43. 4-.
.5b7.1(4 k;1/2c-uk- 12q0-60501
yE- IN s[ata ;s ► o4 corvOr/4 . PI4n$ rc Attie t W:kl, yg'scale .
36•
ver -,Ci bre•skcv- kAIOUl4 G14+19 ;hshtled o►. died cA FA- c.;rc.ni",k,r44-
41r,r4d0( (%otae. r ckcIn4 464 ke% e75.3.P -i'O i(wri k 1134 •
SYSKL-LEGE\
SYMBOL
°wk
OTY.
PART #
DESCRIPTION
3
PC2R
HORN/STROBE
0
1
SR
STROB
0
1
SKY LUN I AL I
W/RESISTER
HOOD INPUT
as ha►�, (54-,44,e Z.
X
�IS
E�
DAG
SAV
�x
PAID
JUN 29 2011
TUKWILA FIRE
�7 ,ice_ jp z
General Nokia
No.
Revieion/Issue
Dates
4eq, My ." -
NW ELECTRIC SERVICE INC
(NWELEE592SDL)
32419 3RD AVE SW
FEDERAL WAY WA 98023
PH: (206)778-7970
SAHALA CAFE
13919 PACIFIC HWY #102
TUKWILA WA 98168
PH: (206)778-7970
FlIt ALARM
°wk
8725/11
FA
L
ID Without Comments
DAs Noted in Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau .,or cynforma^ce with current City
s7 andards. Acceptance +s sutnect to errors and
o, nissions which do nni du`norize violations of adopted
--andards and ord 'lances. The responsibility for the
4quacy of design res -As totally with the designer.
ditions, deletions or revisions to these drawings after
iv.is date will void nic otence and will require a
resubmittal of revised d: a�.i ngs for subsequent approval.
=final acceptance is subject to field test and inspection by
The Tu—a Tukwila Fir Prevention Bur au.
/
Date: — Co J ` J(By: l 1
TUK W!ILA FIRE DEPARTMENT
Please call 206-5)5-4407 and
give this rElie Permit No.
and exact address for shut-
down
hutdown or restoration approval.
NOTICE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
termination of the testinn.
SK5895XL FACP
Unused
Unused
Device Description
SAHALA CAFE
Battery Calculation Worksheet - Power Supply
(all currents stated in mA)
# of Devices
System Devices
mA Draw each Total mA Draw
Stand By Alarm Stand By Alarm
40 160 40 160
0 0 0 0
0
2WB System Sensor HEAT(EXISTING)
SYSTEM SENSOR PULL STATION
Unused
Unused
Initiation Devices / Auxiliary Devices
0.05
0.05
0
0.6
0.25
0
0
1560
650
0
0
Device Totals
P2R STROB @75CD
SR STROB RESTROOM@15 CD9Existing)
P2R(EXISTING)
Unused
Unused
Unused
Unused
Notification Appliances (list all)
Circuit 1
0
0
0
0
0.
0
0
107
79
107
0
0
0
0
0.85 2210 I
321
79
642
0
0
0
0
Circuit 1 Totals'
1042
P2R Horn and Strob@75CD {Existing)
Unused
Unused
Unused
Unused
Unused
Unused
Circuit 2
Circuit 2 Totals<
176
0
0
0
0
0
0
0
0
1056
0
0
0
0
0
0
1056
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Circuit 3
0
0
0
0'
0
0
0
0
0
0
0
0
0
0
0
0
0
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Circuit 4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Circuit 4 Totals
0
0
Notification Appliances Total Current
0
2098
Fire Com NW
2011-06-29
Page 1
Design Voltage
24
Voltage Drop Calculation Worksheet
Circuit #1
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 1.042 14 0.53 1.31 22.69 5.47%
Circuit #2
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250
1.056 14 053 1.33 22.67 5.55%
Circuit #3
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 0 14 0.00 0.00 24.00 0.00%
Circuit #4
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250
0 14 0.00 0.00 24.00 0.00%
Standby Hrs.
Alarm Sounding Minutes
Total System Standby mA
Total System Alarm mA
Total System Standby Ah
Total System Alarm Ah
Min. Ah Battery
Derating Factor
Battery Ah
....................................
....................................
Battery 1isei
Fire Com NW
Summary Section
Required
24
5
40.85
4468
0.980
0.372
1.353
20%
1.691
2011-06-29
Available
Page 2
FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS
Project Name: Saha! Cafe
13919 Tukwila Intl. BI.
Permit No.: 11-H-113
Date: May 24, 2011
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206)575-4407
• Nozzle heights above appliances to be per manufacturers installation guidelines.
• Fryers shall be installed with at least a 16 inch space between the fryer and
surface flames from adjacent cooking equipment or a minimum 8 inch high steel
or tempered glass baffle plate shall be installed between the appliances.
• Upon activation of the suppression system, the make-up air supply will shut off
and the exhaust will keep running.
• Type 1 hood systems shall be designed and installed to automatucally activate
the exhaust system whenever cooking operations occur. The activation of the
exhaust system shall occur through an interlock with the cooking appliances, by
means of heat sensors or by means of other approved methods.
• Activation of the suppression system shall shunt all electrical power under the
hood as well as the gas supply.
• Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment.
• The hood suppression system shall be monitored by a U.L. Central Monitoring
Station.
• The suppression system manual pull station shall be located no closer than 10 ft.
and no farther than 20 ft. from the cooking equipment and be placed at a height
of 42 to 48 inches above the floor.
• The inside lower edge of the hood shall overhang or extend a horizontal distance
of not less than 6 inches beyond the edge of the top horizontal surface of the
appliance on all open sides. The vertical distance between the front lower lip of
the hood and such surface shall not exceed 4 feet.
• If cooking appliances are wheeled, the appliance wheels shall be set in tracks
permanently mounted to the floor to ensure appliance is returned to original
location if moved for cleaning or maintenance.