Loading...
HomeMy WebLinkAboutPP - 13919 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS13919 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 11-F-144 11-H-113 93-F-045 S C i'- fib re ..r D e.L E A.+ +o re.c r )eLlc, 6edroorn IA) %ec1ro o n.. ILI c.�-tAk1 rob Vv\ 13c 1Ci /L- 4 --7/ 1 6 / 1 O / 1 O �.2 74\5.-71l`c--T/oke 4 r or in v,r0 H MS "4 - pat en4 U ctvsr s / rfccej�cl yvC L� r v� fl eiv7 WITHOUT COMMENTS. AS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted byc..the City of— Tukwila Fire Dept. Additions, deletions or revisions to these drawings after thi(, date will void this acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - ins ;)n by a,ee resentative this Oa BY: 57,-- CITY v CITY OF TUKWILA 575-4407 VIIMIIINARBOXICSIMIDENUMMIMMICESZEISIRMENIMIN 1 r 1Y\ re-‘ P c=fit. '` G.CQS r-A�43 ►�s TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job No. ?3— /r-0 5 and exact address for shut- down or restoration approval. MS MS Li" rl 13a4}eri nc 5% en \- \s\ -._1:,4_11.933,2„..5,2,,a4. B o.AN t T ‘ e 1 12, v o L7 ^l A NA " Y U 0. 5 G " WC) -1 1 S►len - kri1611"‘- tt 5 20 IA s-i-tAnAyt.y .02,0A 21-1 `,c- t3 ec.t0 2antl ( • ..t3 Current/ tical,.) Dt -et or Tm-i-ce.t S -}ani, i�rruJ ytcg,ai ortac) •fat- 21-1 bets fI111Gc+a Slt !tel Loo c (1 -toms on\1).(1-1) = • 12414._, m\no+e, : nc - olf c.urr n-1- To+(.1 tarn H rata 2 .25 "l\Arno -%1)c) d2*rs' 5 " \9,11.1-1 9r.%&" /N 12 1 % At)Z-Aexhc . Scno1kp e.,Aor II RI1.6 2w,re. 2-400 1 -loco Whtel >:-I1'—el j -R N0ccl V4.1.%-Fco(ADA) Wlnsfe t.11.. # EN -ELI -W M -24 SOI; & p Ire, w►re S�x�1ea -{o vs�ll FPI- w,re-,/S1gevel vn4 r '17' 7'ti\n\ T. Vu Thu T. OOo t 3c11ct /21 / 23125 14w1 S. Tukw,ta W A 4 1 SCALE: 3 " to DATE: Fos, az, 4 3 APPROVED BY: DRAWN BY 2,..+ REVISED Yn9ro.nn L 1e.c�-r1L 1 Inc. .0- (ex 55214. ec.ttle , v1/4111, ct btSS -0214 '-1to1- `3 V12- 1306 DRAWING NUMBER 18 X 24 PRINTED ON NO. 1000H CLEARPRINT • LEGE\ 3 <WIRE SCHEDULE> —Z—: 14 AWG 2 CONDUCTOR —X—: 16 AWG 2 CONDUCTOR <CANDELA RATE NOTE> 1. 75 CANDELA FOR HORN/STROBE 2. 30 CANDELA FOR STROBE 4 Rau, -,s hot k. CIa, c httniz q t I beat k43. 4-. .5b7.1(4 k;1/2c-uk- 12q0-60501 yE- IN s[ata ;s ► o4 corvOr/4 . PI4n$ rc Attie t W:kl, yg'scale . 36• ver -,Ci bre•skcv- kAIOUl4 G14+19 ;hshtled o►. died cA FA- c.;rc.ni",k,r44- 41r,r4d0( (%otae. r ckcIn4 464 ke% e75.3.P -i'O i(wri k 1134 • SYSKL-LEGE\ SYMBOL °wk OTY. PART # DESCRIPTION 3 PC2R HORN/STROBE 0 1 SR STROB 0 1 SKY LUN I AL I W/RESISTER HOOD INPUT as ha►�, (54-,44,e Z. X �IS E� DAG SAV �x PAID JUN 29 2011 TUKWILA FIRE �7 ,ice_ jp z General Nokia No. Revieion/Issue Dates 4eq, My ." - NW ELECTRIC SERVICE INC (NWELEE592SDL) 32419 3RD AVE SW FEDERAL WAY WA 98023 PH: (206)778-7970 SAHALA CAFE 13919 PACIFIC HWY #102 TUKWILA WA 98168 PH: (206)778-7970 FlIt ALARM °wk 8725/11 FA L ID Without Comments DAs Noted in Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau .,or cynforma^ce with current City s7 andards. Acceptance +s sutnect to errors and o, nissions which do nni du`norize violations of adopted --andards and ord 'lances. The responsibility for the 4quacy of design res -As totally with the designer. ditions, deletions or revisions to these drawings after iv.is date will void nic otence and will require a resubmittal of revised d: a�.i ngs for subsequent approval. =final acceptance is subject to field test and inspection by The Tu—a Tukwila Fir Prevention Bur au. / Date: — Co J ` J(By: l 1 TUK W!ILA FIRE DEPARTMENT Please call 206-5)5-4407 and give this rElie Permit No. and exact address for shut- down hutdown or restoration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testinn. SK5895XL FACP Unused Unused Device Description SAHALA CAFE Battery Calculation Worksheet - Power Supply (all currents stated in mA) # of Devices System Devices mA Draw each Total mA Draw Stand By Alarm Stand By Alarm 40 160 40 160 0 0 0 0 0 2WB System Sensor HEAT(EXISTING) SYSTEM SENSOR PULL STATION Unused Unused Initiation Devices / Auxiliary Devices 0.05 0.05 0 0.6 0.25 0 0 1560 650 0 0 Device Totals P2R STROB @75CD SR STROB RESTROOM@15 CD9Existing) P2R(EXISTING) Unused Unused Unused Unused Notification Appliances (list all) Circuit 1 0 0 0 0 0. 0 0 107 79 107 0 0 0 0 0.85 2210 I 321 79 642 0 0 0 0 Circuit 1 Totals' 1042 P2R Horn and Strob@75CD {Existing) Unused Unused Unused Unused Unused Unused Circuit 2 Circuit 2 Totals< 176 0 0 0 0 0 0 0 0 1056 0 0 0 0 0 0 1056 Unused Unused Unused Unused Unused Unused Unused Circuit 3 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 0 Unused Unused Unused Unused Unused Unused Unused Circuit 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Circuit 4 Totals 0 0 Notification Appliances Total Current 0 2098 Fire Com NW 2011-06-29 Page 1 Design Voltage 24 Voltage Drop Calculation Worksheet Circuit #1 Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop % 250 1.042 14 0.53 1.31 22.69 5.47% Circuit #2 Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop % 250 1.056 14 053 1.33 22.67 5.55% Circuit #3 Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop % 250 0 14 0.00 0.00 24.00 0.00% Circuit #4 Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop % 250 0 14 0.00 0.00 24.00 0.00% Standby Hrs. Alarm Sounding Minutes Total System Standby mA Total System Alarm mA Total System Standby Ah Total System Alarm Ah Min. Ah Battery Derating Factor Battery Ah .................................... .................................... Battery 1isei Fire Com NW Summary Section Required 24 5 40.85 4468 0.980 0.372 1.353 20% 1.691 2011-06-29 Available Page 2 FIRE DEPARTMENT HOOD SUPPRESSION PLAN REVIEW COMMENTS Project Name: Saha! Cafe 13919 Tukwila Intl. BI. Permit No.: 11-H-113 Date: May 24, 2011 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Nozzle heights above appliances to be per manufacturers installation guidelines. • Fryers shall be installed with at least a 16 inch space between the fryer and surface flames from adjacent cooking equipment or a minimum 8 inch high steel or tempered glass baffle plate shall be installed between the appliances. • Upon activation of the suppression system, the make-up air supply will shut off and the exhaust will keep running. • Type 1 hood systems shall be designed and installed to automatucally activate the exhaust system whenever cooking operations occur. The activation of the exhaust system shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. • Activation of the suppression system shall shunt all electrical power under the hood as well as the gas supply. • Install a "K" rated portable fire extinguisher within 30 ft. of the cooking equipment. • The hood suppression system shall be monitored by a U.L. Central Monitoring Station. • The suppression system manual pull station shall be located no closer than 10 ft. and no farther than 20 ft. from the cooking equipment and be placed at a height of 42 to 48 inches above the floor. • The inside lower edge of the hood shall overhang or extend a horizontal distance of not less than 6 inches beyond the edge of the top horizontal surface of the appliance on all open sides. The vertical distance between the front lower lip of the hood and such surface shall not exceed 4 feet. • If cooking appliances are wheeled, the appliance wheels shall be set in tracks permanently mounted to the floor to ensure appliance is returned to original location if moved for cleaning or maintenance.