HomeMy WebLinkAboutPP - 15252 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS15252 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 05-F-189 RCO REMODEL SHEET # DESCIPTIO\ FA -01 SYSTEM I\FORMATION FA -02 TYPICAL WIRING AND MOUNTING DETAILS FA -03 FLOOR PLAN - FIRE ALARM FA -04 RISER DIAGRAM SHEET LIST WIRE SCHEDULE AND CONDUIT FILL CHART SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FIRE ALARM NOTE: ADDRESSABLE DEVICE BAR CODE LABEL SHALL BE TRANSFERRED TO FIELD COPY PRINTS AS INSTALLED. 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, 1999 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 4-4.4) AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES OR 6" FROM CEILING, WHICHEVER IS LOWER (CH.. 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 1 10cd (CH. 4-4.4.3.2) 2. ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER; THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL 7. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE ELECTRICAL CONTRACTOR:;" ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 9. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/DR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 11. PER NFPA 1999 EDITION PAGE 72-35. 2-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL TRADES IS 12. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 13. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 14. POINT AND COMMON ANNUNCIATION AND T -TAPPING ARE PROHIBITED (EXCEPT SLC LOOP). 15. PROVIDE 3/4" CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATION MONITORING. 16. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB 17. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY. 18. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 19. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 20. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 21. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND 22. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. 23. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. 24. A SET OF AS BUILT DRAWINGS TO BE TURNED INTO GSSINC WITH APPROPRIATE COLOR CODED MARKUP DRAWINGS (SEE SYMBOL LEGEND FOR COLOR CODING). TU KW I LA SYSTEM QUANTITY 1 1 3 6 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FA FIRE ALARM CONTROL PANEL QS 1-1-G-1 EST PROVIDED 66" A.F.F. TO TOP R/A REMOTE ANNUNCIATOR QSA-1-S EST PROVIDED 66" A.F.F. TO TOP F MANUAL PULL STATION SIGA-270 EST 4S DEEP BOX 1 -GANG RING 48" A.F.F. TO CENTER O AREA SMOKE DETECTOR SIGA-PS EST (PHOTOELECTRIC) SIGA-SB 4S 2-1/8" DEEP BOX CEILING O THERMAL DETECTOR SIGA-HRS EST (FIXED/RATE OF RISE) SIGA-SB 4S 2-1/8" DEEP BOX CEILING `o' FIRE ALARM. HORN/STROBE G1-HDVM EST 4S BOX 80" A.F.F. TO BOTTOM 'o' WP FIRE ALARM HORN/STROBE 757 -7A -T EST 757A -WB 80" A.F.F. TO BOTTOM FIRE ALARM n STROBE (WALL) G1 -VM EST 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM QF HORN/STROBE (CEILING) GC-HDVM EST 4S BOX CEILING 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A VL VERIFY LOCATION IN FIELD N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1 CCEPTE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and o ,finances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /2-7/ 0 ByatVe 11KW1LA FIRE DEPARTMENV, Please call; 575.4407 end give this job and exact address for shut- down or restoration approval. NOTICE A completed, signed, Tukw Fire Department Pre-test Certificate must be present to the Inspector prior to commencement of Acceptar Testing of •any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing. F1L FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS co w o' 0 U) DESCRIPTION J 0 IY a. 4 0 h. w 1- COJ w a 0 0 0 0 z C C C C U PAID SEP 16 2005 Tukwila Fire SCALE: NOT Z 0 0 Z N uJ >NI0 (/) TO SCALE DRAWN BY: S.TALBOTT DESIGNED BY: B.VEZZAN I DATE: 09/08/05 BACKROUND PLAN PROVIDED BY: BARGHAUSEN .OB NUMBER: GENERAL NOTES SHEET SYMBOL LIST *7' FA -0 Copyright 2004 by Guardian Security Systems, Inc. All Rights Reserved j WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE D D' P S S' N I A DATA LINE -ADDRESSABLE LOOP - FEED TWISTED PAIR #16 FPL/FPLR RED (JACKET) DATA LINE -ADDRESSABLE LOOP - RETURN TWISTED PAIR #16 FPL/FPLR RED (JACKET) DEVICE POWER - 24VDC PAIR #14 FPL/FPLR RED (JACKET) SIGNALING CIRCUIT. (STROBE) - FEED TWISTED PAIR WITH SHIELD #14 FPL/FPLR RED (JACKET) SIGNALING CIRCUIT (STROBE) - RETURN TWISTED PAIR WITH SHEILD #14 FPL/FPLR RED (JACKET) DEVICE POWER - 24VDC (ANNUNCIATOR) PAIR #14 FPL/FPLR RED (JACKET) INITIATION TWISTED PAIR #18 FPL/FPLR RED (JACKET) ANNUNCIATOR DATA TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF CONDUIT SIZE MAXIMUM FLL 1/2" .12 SQUARE 3/4" .21 SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-1/2" .82 SQUARE 2" 1.34 SQUARE FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM DIMENSIONS AREA .244 0.D. .0467 .210 0.D. .0346 .156 0.D. .0191 CONDUIT FROM THE TABLE FILL DIMENSION FROM THE WIRE. NCH NCH NCH NCH NCH INCH N.E.C., CHP. 9, TABLE 4. , SHIELDED WIRE TO BE GROUNDED AT POINT OF ORIGIN PUNCHED THROUGH EACH DEVICE WRAPPED WITH TAPE AND TAPED AT END WIRE DESIGNATION FIRE ALARM NOTE: ADDRESSABLE DEVICE BAR CODE LABEL SHALL BE TRANSFERRED TO FIELD COPY PRINTS AS INSTALLED. 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NFPA 72, 1999 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 4-4.4) AND REQUIRES A MINIMUM OF 90" TO TOP FOR AUDIBLE DEVICES OR 6" FROM CEILING, WHICHEVER IS LOWER (CH.. 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE NOTIFICATION SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24" FROM CEILING TO TOP OF LENS FOR 1 10cd (CH. 4-4.4.3.2) 2. ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC. 4. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER; THAN 3 FEET (900mm) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL 7. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE ELECTRICAL CONTRACTOR:;" ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 9. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/DR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH APPROVED SMOKE. 11. PER NFPA 1999 EDITION PAGE 72-35. 2-3.6.1.3 DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEANUP OF ALL TRADES IS 12. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 13. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE POSSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 14. POINT AND COMMON ANNUNCIATION AND T -TAPPING ARE PROHIBITED (EXCEPT SLC LOOP). 15. PROVIDE 3/4" CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATION MONITORING. 16. THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT NOISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB 17. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON -ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY. 18. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 19. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). 20. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 21. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND 22. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. 23. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. 24. A SET OF AS BUILT DRAWINGS TO BE TURNED INTO GSSINC WITH APPROPRIATE COLOR CODED MARKUP DRAWINGS (SEE SYMBOL LEGEND FOR COLOR CODING). TU KW I LA SYSTEM QUANTITY 1 1 3 6 2 1 SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT FA FIRE ALARM CONTROL PANEL QS 1-1-G-1 EST PROVIDED 66" A.F.F. TO TOP R/A REMOTE ANNUNCIATOR QSA-1-S EST PROVIDED 66" A.F.F. TO TOP F MANUAL PULL STATION SIGA-270 EST 4S DEEP BOX 1 -GANG RING 48" A.F.F. TO CENTER O AREA SMOKE DETECTOR SIGA-PS EST (PHOTOELECTRIC) SIGA-SB 4S 2-1/8" DEEP BOX CEILING O THERMAL DETECTOR SIGA-HRS EST (FIXED/RATE OF RISE) SIGA-SB 4S 2-1/8" DEEP BOX CEILING `o' FIRE ALARM. HORN/STROBE G1-HDVM EST 4S BOX 80" A.F.F. TO BOTTOM 'o' WP FIRE ALARM HORN/STROBE 757 -7A -T EST 757A -WB 80" A.F.F. TO BOTTOM FIRE ALARM n STROBE (WALL) G1 -VM EST 4S BOX 80" A.F.F. TO BOTTOM FIRE ALARM QF HORN/STROBE (CEILING) GC-HDVM EST 4S BOX CEILING 0 JUNCTION BOX F.B.O. F.B.O. N/A VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A F.B.O. FURNISHED BY OTHERS N/A N/A N/A N/A N/A NOT APPLICABLE N/A N/A N/A N/A U.O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A VL VERIFY LOCATION IN FIELD N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A RED AS BUILT ADD OR CHANGE N/A N/A N/A N/A GREEN AS BUILT REMOVE N/A N/A N/A N/A BLUE AS BUILT NOTES TO CAD N/A N/A N/A N/A 1 CCEPTE Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and o ,finances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: /2-7/ 0 ByatVe 11KW1LA FIRE DEPARTMENV, Please call; 575.4407 end give this job and exact address for shut- down or restoration approval. NOTICE A completed, signed, Tukw Fire Department Pre-test Certificate must be present to the Inspector prior to commencement of Acceptar Testing of •any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing. F1L FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS co w o' 0 U) DESCRIPTION J 0 IY a. 4 0 h. w 1- COJ w a 0 0 0 0 z C C C C U PAID SEP 16 2005 Tukwila Fire SCALE: NOT Z 0 0 Z N uJ >NI0 (/) TO SCALE DRAWN BY: S.TALBOTT DESIGNED BY: B.VEZZAN I DATE: 09/08/05 BACKROUND PLAN PROVIDED BY: BARGHAUSEN .OB NUMBER: GENERAL NOTES SHEET SYMBOL LIST *7' FA -0 Copyright 2004 by Guardian Security Systems, Inc. All Rights Reserved j WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW BATTERY SIZING CALCULATI❑N A A Job Name: Panel Location: Date Performed: Arco Remodel - Tukwila QuickStart Battery Calculation 09-08-2005 QTY. DEVICE NAME STD -BY( Amps) ALARM( Amps) 1 EST: QS1 3 EST: SIGA-270 4 EST: SIGA-HRS 6 EST: SIGA-PS 1 H/S: 757-7A 1 H/S: G1-HDVM (15) 1 H/S: G1-HDVM (75) 1 H/S: GC-HDVM (75) 4 HIS: GC-HDVM (95) 1 STR: G1 -VM (15) 1 ANN: QSA1 0. 1170 0. 0008 0. 0002 0, 0003 0, 0000 0. 0000 0, 0000 0, 0000 0. 0000 0, 0000 0, 1050 0, 1350 0, 0001 0. 0000 0. 0000 0. 2040 0. 0810 0. 1610 0. 1850 0. 8480 0. 0590 0. 1230 Stand -By Load = Stand -By Time = Tota l s = 0. 2232 0, 2232 Amps 24 Hrs. Stand -By = 5. 36 Amp)1(Hrs Total = Stand -By + Alarm = 5. 36 + 0, 15 = 5. 51 Amp*Hrs 1. 7962 Alarm Load = 1.7962 Amps Alarm Time = 5/60 Hrs. Alarm = 0,15 Amp*Hrs Multiply by De -Rating Factor of' 1. 25 ---> 5.51 * 1, 25 = 6.88 WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW )1( MINIMUM BATTERY SIZE = 6.88 Ampere*Hours WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW **** RECOMMENDED MINIMUM BATTERY SIZE = 7.00 Ampere*Hours WWWWWWW wAwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww A WORST CASE VOLTAGE DROP CALCULATION A A A Job Name: Circuit: Date Performed: Arco Remodel - Tukwila Voltage Drop Calculations 09-08-2005 1 H/S: 757-7A 1 H/S: G1 -HDVM (15) 1 - H/S: G1-HDVM (75) 1 HIS: GC-HDVM ( 75) 4 H/S: GC-HDVM (95) 1 STR: G1 -VM ( 15) at at at at at at 0, 2040 0. 0810 0. 1610 0. 1850 0. 2120 0. 0590 Amps Amps Amps Amps Amps Amps each each each each each each = 0. 2040 = 0. 0810 = 0. 1610 = 0. 1850 = 0. 8480 = 0, 0590 Amps Amps Amps Amps Amps Amps Circuit Length = Circuit Load = Vo l tage Drop = Voltage Drop = 220 Ft to End 1. 5380 Amps C Ckt, Load) NE (Ckt, Total = 1.5380 Amps Wire Size = #14 AWG Voltage = 24.0 Volts Length) NE 21. 6 (Circular Mils) NE (Volts) ( 1. 5380 ) * ( 220 ) ) 21. 6 ( 4110 ) * ( 24. 0) Voltage Drop = 7. 41% wwwwwwwwwwwwwwwwwwwwwwwwwww N VOLTAGE DROP = 7. 41% NE w 100% NE 100% z 0 z cn LU J I - a LU C/)O LLl F-- -4 N- FAX (206) 628-4990 TEL. (206) 622-6545 SYSTEM CALCULATIONS ALARM STROBE R E 80" A.F.F. MANUAL PULL CI STATION 0 0 0 ©48" TO PULL 4S DEEP BOX W/ OPTIONAL 1G RING 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING HEIGHT REQUIREMENTS PULL STATION - STRO3E COMBINATION HORN/STROBE FIR 80" A.F.F. MANUAL PULL STATION 0 4S DEEP BOX W/ OPTIONAL 1G RING 4" SQUARE DEEP BACK BOX WITH 10 TRIM RING HEIGHT REQUIREMENTS PULL STATION - HORN/STROBE WALL MOUNTED FIRE ALARM DEVICE MOUNTING ELEVATIONS FROM FACP DATA INC-) OR PREVI❑US DATA INC+) DEVICE SIGA-HRS DATA OUT(-) INTELLIGENT FT/ROR HEAT DETECTOR BASE WIRING DIAGRAM TO NEXT DATA MICA-) DEVICE FROM FACP DATA INC+) TB2 TB1 0 0 7 SIGA ;270 RED GRN LED LED 00 00 ALARM/ NORMAL ACTIVE 0 3 0 2 0 1 0 OR PREVIOUS DATA INC-) DEVICE FROM FACP DATA IN(-) OR PREVIOUS DATA IN(+) DEVICE DATA ❑UT(+) ► TO NEXT DATA ❑UTC-) DEVICE MANUAL PULL STATION SINGLE STAGE WIRING DIAGRAM SIGA-PS DATA OUT(-) TO NEXT DATA OUT(+) DEVICE INTELLEGENT PHOTOELECTRIC SMOKE DETECTOR BASE WIRING DIAGRAM FROM REMOTE POWER SUPPLY OR FACP + HORN/STROBE OR STROBE ONLY + - HORN/STROBE OR STROBE ONLY u � + - HORN/STROBE OR STROBE ONLY HORN/STROBE AND STROBE WIRING COMPATIBLE ELECTRICAL' BOX BACK PLATE TOGGLE SWITCH �- GLASS ROD RELEASE LEVER SIGA-270 MOUNTING DETAIL TO NEXT DEVICE OR END OF LINE COVER RELEASE SCREW INSTALL EST SIGA SERIES 270/278 MANUAL PULL STATION USING STANDARD 1-1/2" DEEP RELEASE/REVISIONS DESCRIPTION J 4 0 a.a- 4 0 w I- 2 m to W I- Q 0 rn 0 0) 0 0 z C C C C 2FT.°m 0>i � �Nr .•=( N3Q L1Jo gi> 05'1 ill1(''(1! CC Vet� 00Li NF CC a. 1(.0 /S--CALE: NOT TO SCALE DRAWN BY: S.TALBOTT DESIGNED BY: B.VEZZAN I DATE: 09/08/05 BACKROUND PLAN PROVIDED BY: BARGHAUSEN TYPICAL WIRING AND MOUNTING .0B NUMBER: Copyright 2004 by Guardian Security Systems, Inc. All Rights Reserved SHEET ,[ ] r '75cd S1-1- 71 2 -n S A,N —o T€,4-2OVA - E -;CIRCUIT D 2-S b I l 15cd S1-1-1 95cd S1-1-3 1 EOL S1-1 .r 95cd S1-1-8 s. 75td S1-1- D—a r>=--7f, , ••// 150'' :S1-1-6 CD -2S 21 95cd S1-1-4 95cd S1-1-7 [' 1 A,N 75cd S1-1-9 1 00 FI 4\ = I I AI AVI FLAG NOTES: FIELD LOCATE FIRE ALARM CONTROL PANEL. SURFACE MOUNT HEATED ENCLOSURE WITH REMOTE ANNUNCIATOR. --- We) cle--1-c-c_ c21-') ot 4,67c9e_,. CCie6( sef,_ ri•ht 2004 b Guardian Securit S stems, Inc. All R. hts Reserved RELEASE/REVISIONS m w rr 0 U) DESCRIPTION J 4 0 (1- (1. o. 4 0 L7. w I— �t 0 0 6ALE: 1/4" = 1'0" DRAWN BY: S.TA LBOTT DESIGNED BY: B.VEZZAN I DATE: 09/08/05 BACKROUND PLAN PROVIDED BY: BARGHAUSEN \ 0B NUMBER: SHEET FA -03 0 R /A B A 2S HEATED ENCLOSURE FA QS1 FIELD LOCATE V S1-1-1 S1-1-2 15cd 75cd TO 120VAC \\\ s E CIRCUIT F.B.O. S1-1-3 95cd S1-1-4 95cd S1-1-5 75cd L S1-1-6 15cd EOL S1-1 S1-1-7 95cd 2S v wP b „ S1-1-8 S1-1-9 95cd 75cd Copyright 2004 by Guardian Security Systems, Inc. All Rights Reserved 1743 IST AVE. SO., SEATTLE, WASHINGTON 98134 FAX (206) 628-4990 TEL. (206) 622-6545 RELEASE/REVISIONS co W DESCRIPTION J 4 0 0. 0. 4 0 0 w E- I - 2 D 0 w I -- a U, 0 0 0 i 6ALE: NOT TO SCALE DRAWN BY: S.TALBOTT DESIGNED BY: B.VEZZAN I DATE: 09/08/05 BACKROUND PLAN PROVIDED BY: BARGHAUSEN SOB NUMBER: SHEET FA -04