HomeMy WebLinkAboutPP - 15666 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS15666 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS NONE c UN CUN c F!I Ii t A AN OLYMPIA FLEET 8c SUPPLY AND SOUTH KI\G COUNTY PROJECT NO. 92-054 DESIGN; CONSULTANT 401 2ND AVE. S. * SUITE 201 * SEATTLE, WA 98104 TEL. (206) 583-0200 * FAX (206) 583-8826 mr- LEGEND A AIR CW COLD WATER EC ELECTRICAL CONDUIT S SANITARY SEWER SD STORM DRAIN LIGHT W/STANDARD DRAWING SCHEDULE { M1 OLYMPIA FLEET AND SUPPLY DEMOLITION PLAN M2 OLYMPIA FLEET AND SUPPLY NEW WORK PLAN M3 SOUTH KING COUNTY DETACHMENT DEMOLITION PLAN M4 SOUTH KING COUNTY DETACHMENT NEW WORK PLAN M5 UNDERGROUND STORAGE TANK DETAILS M6 UNDERGROUND STORAGE TANK DETAILS APPROVALS _L'Y 'iULLIL4 ) WASHINCl.T ON STATE PATROL ENGINEERING & ARCHITECTURAL SERVICES APPROVED AS NOTED The drawings affixed hereto have been reviewed and accepted as meeting or exceeding minimum requirements of the City of Tukwila Fire Dept , Bureau of Fire Prevention Additions or revisions to these drawings after this date shall not be construed as being approved r reviewed CITY OF TUKWILA BUREAU OF FIRE PREVENTION ILE 1 EXISTING ESI CARD READER. REMOVE CARD READER AND RETAIN FOR RE -USE. RETAIN ELECTRICAL CIRCUIT TO CARD READER FOR RE -USE. DISCONNECT ELECTRICAL CIRCUITS, WATER AND AIR LINES TO WATER/AIR HOSE REEL AND RETAIN FOR RE -USE. CONTRACTOR IS TO REMOVE AND PROPERLY DISPOSE OF PUMP ISLAND AND PUMP ISLAND EQUIPMENT. CONTRACTOR MUST RETAIN OVERHANGING CONCRETE ROOF, COLUMNS AND FOOTINGS. ADDITIONAL SUPPORT FOR THE CONCRETE ROOF MAY BE REQUIRED DURING PUMP ISLAND DEMOLITION. r; , 1 PNL B PNIL IC I! 1 1-1/2" TANK VENT, CUT AT GRADE AND ABANDON REMAINDER IN PLACE EMERG SHUT-OFF AIR COMPRESSOR SHUT-OFF VALVE DRY WELL x x r /- 6" CAST / IRON SD .. -x GRAVEL A. EXISTING FENCE-, - - -x —Lx-- EXISTING EXPOSED CONDUIT ROUTED CN UNDERSIDE CF CONCRETE ROOF - V— 4" S C 0. .,- 4" CAST or IRON —EC =-{A 0 —EC a EXISTING ESI CARD READER � I 1I / J 11 , / EXISTING ESi-' PRINTER U w 1 REMOVE BELLS SYSTEMS PUSHBUTTON SWITCH LIMITS OF CONCRETE --x x -x SD ALTERNATE NO. 1 LOCATION OF 1,500 GALLON ABANDONED FUEL TANK. REMOVE AND PROPERLY DISPOSE OF TANK, INCLUDING VENT AND SUPPLY PIPING 2" TANK VENT x X4- ---x x-- 1 % CONTRACTOR IS TO REMOVE INDICATED PORTION OF CHAIN LINK FENCE AND RE -INSTALL AFTER COMPLETION OF WORK I Ir — OFFSET iALL LINES , pimig 1 1 IL L_J i1 ---J n M APPROXIMATE LIMITS OF CONCRETE CUT 4" CAST IRON E4" S C.O. x x --a4 -- TEMPORARY TEMPORARY FENCE LOCATION (BY OWNER) LOCATION OF FUEL TANKS. REMOVE AND PROPERLY DISPOSE OF TWO 10,000 GALLON UNLEADED FUEL TANKS INCLUDING VENTS AND SUPPLY PIPING ` SD —® DRY APPROXIMATE LIMITS WELL OF ASPHALT CUT \ £1 "- GRAVEL THIS SIDE OF FENCE (ce( X-- -- ASPHALT THIS SIDE OF FENCE -\ SD CB [-EXISTING EXISTING FENCE -x x -4- - x 1 \\ f \ I OLYMPIA FLEET AND SUPPLY arP DEMOLITION PLAN X - \ T \,/I � SD SCALE: 1" = 20'-0" CB 4 x I GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE LOCATOR SERVICE. 2. ALL WORK SHALL BE PERFORMED BY CONTRACTOR AND SUPERVISOR LICENSED FOR TANK DECOMMISSIONING. 3. OWNER SHALL PROVIDE SOIL SAMPLING AND TESTING PER DOE SITE ASSESSMENT REQUIREMENTS. 4. TANKS HAVE CONTAINED LEADED FUEL DISPOSE OF SLUDGE AS HAZARDOUS WASTE. 5. ANY DAMAGE TO EXISTING FACILITES DURING COURSE OF WORK SHALL BE RESTORED OR REPLACED AT CONTRACTOR'S EXPENSE. lc I --- Z W W 0Q J Lu cc Z O F.-- Lu Q 0 d. Q CC OI I --V) V? p Z Z 0 O F_ O 0 Ce Z O CC 2 LU I~' 0 LU —a 0 CC a_ PROJECT NO. 92-054 DATE: 8/27/92 SHEET TITLE: OLYMPIA FLEET AND SUPPLY DEMOLITION SHEET NO. M-1 Z O EE 0 N W Q V) z O_ N S w Er (DATE O Z lc I --- Z W W 0Q J Lu cc Z O F.-- Lu Q 0 d. Q CC OI I --V) V? p Z Z 0 O F_ O 0 Ce Z O CC 2 LU I~' 0 LU —a 0 CC a_ PROJECT NO. 92-054 DATE: 8/27/92 SHEET TITLE: OLYMPIA FLEET AND SUPPLY DEMOLITION SHEET NO. M-1 ROUTE EXPOSED CONDUIT APPROXIMATELY 10'-0" UP PNL B l PNL C DRY WELL x - EMERGENCY PUMP SHUT-OFF PROVIDE ISOLATION RELAYS IN MECH/ELECT ROOM FOR ALL POWER CIRCUITS AT ISLAND ‘AIS.„ COMPRESSOR -1 SHUT-OFF VALVE EXISTING EXPOSED CONDUIT ROUTED ON UNDERSIDE OF CONCRETE ROOF EXISTING CARD READER (RELOCATED) x x u 6" CAST IRON 1 D SD EXISTING FENCE x -x \- GRAVEL 2" SUMP/ INTERSTITIAL VENT — v- 4" S C 0 f 4" CAST IRON AIR/WATER HOSE REEL EXISTING COLUMN (2) TYP INDICATES CONDUIT ROUTING, NOT QUANTITY OR SIZE. SEE DIAGRAM SHEET M- 5 . ROUTE CONDUIT ABOVE T -BAR CEILING EXISTING ESI CARD READER AND PRINTER T–BAR CEILING =EC — –EC ■ 0 wci CANOPY-' I . ;n �II RLM 9000 PPM 4100 P/M RELAY J -BOX ( SO ALTERNATE NO. 1 BACKFILL EXCAVATION. BACKFILL SHALL BE COMPACTED TO 95% OR GREATER. PATCH TO GRADE WITH 4" OF ASPHALT OVER 6" OF 5/8" MINUS CRUSHED ROCK LIMITS OF NEW CONCRETE SLAB 6" MIN W/6x6x10 GAUGE W W M F MATCH EXISTING GRADE FILL GAUGE SD ® ROUTE CONDUIT UP EXISTING COLUMN AND SECURE TO UNDERSIDE OF CANOPY LIMITS OF CONCRETE ROUTE EXPOSED CONDUIT APPROXIMATELY 9'-0" ' ABOVE GRADE ON BUILDING WALL [CBI oN_ -x L i BACKFILL EXCAVATION MATCH EXISTING GRAVEL GRADE PIPING SUMP BRINE RESERVOIR SENSOR MONITORING WELL (2) TYPICAL DRY WELL CONTRACTOR TO PROVIDE ADDITIONAL EXCAVATION TO LOCATE TANK/TANK SLAB 2'-0" WEST OF FENCE DO NOT POUR FENCE POSTS WITHIN TANK SLAB x- — x x- - x x \- ASPHALT THIS SIDE OF FENCE PATCH TO MATCH EXISTING GRADE WITH CONCRETE CONDUIT ENTRANCE INTO BUILDING. DRILL HOLE IN BRICK WALL APPROXIMATELY 9'-0" FROM GRADE FOR CONDUIT ENTRANCE SD DRY \h'ELL 4 C P • t GRAVEL THIS SIDE OF FENCE x (cel OLYMPIA FLEET AND SUPPLY \EW WORK PLAN x - x EXISTING FENCE x x x -x --X- p7 [cBi X- SCALE. 1" = 20'-0" x SD x 081 L 19/-0" HOLD-DOWN BOX BRAVO SYSTEMS, 200 SERIES MODEL 2510-3. PROVIDED BY CONTRACTOR PER MFR'S INSTRUCTIONS +op L --J 4 INSTALL AIR AND WATER REEL PER MFR'S INSTRUCTIONS J TANK VENT STEEL PUMP ISLAND FORM (SEE NOTE) EXISTING CANOPY COLUMN (2) TYP s SUMP/INTERSTITIAL VENT RELOCATE EXIS1ING CARD READER TO LOCATION SHOWN. (4) 3/4" CONDUITS TO CARD READER MUST BE PULLED UP THROUGH 5" SQUARE OPENING AT BASE OF CARD READER STAND. (SEE UNDERGROUND CONDUIT DIAGRAM SHEET M- 5 ) NOTE: PUMP ISLAND FORM: 12 GAUGE STEEL, 13" HIGH, 4'-O" WIDE WITH SEMI -CIRCULAR ENDS. TOTAL LENGTH 19'-0". FACTORY FORMED TO REQUIRED SHAPE AS MANUFACTURED BY COXWELL'S (LOS ANGELES), AMFAB (MEMPHIS), OR APPROVED EQUAL. CONTRACTOR SHALL PROVIDE FORMS. AFTER PLACEMENT, PRIME AND PAINT THE PERIMETER BLACK (BK -10 -SLG). PUMP ISLAND PLAN ' N D�TANKt VENT 1 N.T.S 2��0" Q,- SUMP/ MIN INTERSTITIAL VENT COMMERCIAL ZONE PRODUCTS - TOWEL DISPENSER MODEL #DBWC. PROVIDED BY CONTRACTOR. MOUNT TO CANOPY COLUMN @ 48" ABOVE ISLAND CABINET PROVIDED- 1-l' AND INSTALLED I * I � BY OWNER v 18" EXISTING ESI CARD READER AIR/WATER HOSE REEL GENERAL NOTES: 1. FOR TANK INSTALLATION DETAILS, SEE SHEETS M- 5 AND M-6 . REPLACE EXISTING DOWN SPOUT AND RECONNECT TO EXISTING 4" CAST IRON DRAIN UNE NOTE: CONTRACTOR TO RETAIN CONCRETE OVERHANG, CANOPY COLUMNS AND FOOTINGS' PUMP ISLAND DETAIL M M-2 N.T.S. 4" CAST IRON S.D. U W 0 !Y a_ DATE: 8/27/92 SHEET TITLE: OLYMPIA FLEET AND SUPPLY NEW WORK SHEET NO. VI 2 Z O P E (.3 v) W 0 z O_ W x W 1-- < Q 0 O z U W 0 !Y a_ DATE: 8/27/92 SHEET TITLE: OLYMPIA FLEET AND SUPPLY NEW WORK SHEET NO. VI 2 PARTIAL BASEMENT FLOOR PLAN 5 8" LOT DRAIN @ 18" BELOW ASPHALT SD �- MAIN DISTRIBOTION PANEL U PANEL B EXISTING ESI PRINTER I, EXISTING ESI CARD 'READER L r r7 r RETAIN EXISTING FUEL PUMP EMERGENCY SHUT-OFF. PROVIDE ISOLATION RELAYS IN THE MECH/ELECT ROOM FOR ALL POWER CIRCUITS AT ISLAND RETAIN CARD READER CIRCUITS AND CONDUIT WITHIN BUILDING FOR RE -USE —ASPHALT • REMOVE CONCRETE DRIVE SLAB AND GP DE PATCH TO MATCH EXISTING WITH ASPHALT 3 st^ MANHOLE 6" SD RETAIN AIR, WATER LINES AND PUMP ISLAND CIRCUIT, UP TO LOCATION SHOWN FOR RE -USE. CUT AND ABANDON REMAINER OF' LINES AND CONDUIT IN PLACE SD SLOPE • • • V —0 L DEMO GUARD POST 2 CANOPY \ EC `14• ABOVE GRADE REMOVE CARD READER AND PEDESTAL AND RETAIN FOR \ RE -INSTALLATION 1-1/2" TANK VENT SOUTH KING COUNTY DETACHMENT DEMOLITION PLAN X 0 L 1I/ APPROXIMATE LIMITS OF ASPHALT CUT CONCRETE FILL PAD SD WATER METER 1-1/2" SCALE: 1/8" = 1.-0- 10" SEWER LINE 15' BELOW ASPHALT EXISTING / FENCE / r (OBJ LOCATION OF FUEL TANK. REMOVE AND DISPOSE OF EXISTING 10,000 GALLON TANK INCLUDING VENTS, SUPPLY PIPING, DISPENSER, PUMP ISLAND, CANOPY, ETC. GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE LOCATOR SERVICE. 2. ALL WORK SHALL BE PERFORMED BY CONTRACTOR AND SUPERVISOR LICENSED FOR TANK DECOMMISSIONING. 3. OWNER SHALL PROVIDE SOIL SAMPLING AND TESTING PER DOE SITE ASSESSMENT REQUIREMENTS. 4. TANKS HAVE CONTAINED LEADED FUEL DISPOSE OF SLUDGE AS HAZARDOUS WASTE. 5. ANY DAMAGE TO EXISTING FACILITES DURING COURSE OF WORK SHALL BE RESTORED OR REPLACED AT CONTRACTOR'S EXPENSE. o 3 "6 i •'`; .�-.o _ 41-. p h 4•1 o N Lu cc x W ri N DESCRIPTION 1 (n z O En 5 w rr DATE f'ON I PARTIAL BASEMENT FLOOR PLAN 5 8" LOT DRAIN @ 18" BELOW ASPHALT SD �- MAIN DISTRIBOTION PANEL U PANEL B EXISTING ESI PRINTER I, EXISTING ESI CARD 'READER L r r7 r RETAIN EXISTING FUEL PUMP EMERGENCY SHUT-OFF. PROVIDE ISOLATION RELAYS IN THE MECH/ELECT ROOM FOR ALL POWER CIRCUITS AT ISLAND RETAIN CARD READER CIRCUITS AND CONDUIT WITHIN BUILDING FOR RE -USE —ASPHALT • REMOVE CONCRETE DRIVE SLAB AND GP DE PATCH TO MATCH EXISTING WITH ASPHALT 3 st^ MANHOLE 6" SD RETAIN AIR, WATER LINES AND PUMP ISLAND CIRCUIT, UP TO LOCATION SHOWN FOR RE -USE. CUT AND ABANDON REMAINER OF' LINES AND CONDUIT IN PLACE SD SLOPE • • • V —0 L DEMO GUARD POST 2 CANOPY \ EC `14• ABOVE GRADE REMOVE CARD READER AND PEDESTAL AND RETAIN FOR \ RE -INSTALLATION 1-1/2" TANK VENT SOUTH KING COUNTY DETACHMENT DEMOLITION PLAN X 0 L 1I/ APPROXIMATE LIMITS OF ASPHALT CUT CONCRETE FILL PAD SD WATER METER 1-1/2" SCALE: 1/8" = 1.-0- 10" SEWER LINE 15' BELOW ASPHALT EXISTING / FENCE / r (OBJ LOCATION OF FUEL TANK. REMOVE AND DISPOSE OF EXISTING 10,000 GALLON TANK INCLUDING VENTS, SUPPLY PIPING, DISPENSER, PUMP ISLAND, CANOPY, ETC. GENERAL NOTES: 1. CONTRACTOR SHALL PROVIDE LOCATOR SERVICE. 2. ALL WORK SHALL BE PERFORMED BY CONTRACTOR AND SUPERVISOR LICENSED FOR TANK DECOMMISSIONING. 3. OWNER SHALL PROVIDE SOIL SAMPLING AND TESTING PER DOE SITE ASSESSMENT REQUIREMENTS. 4. TANKS HAVE CONTAINED LEADED FUEL DISPOSE OF SLUDGE AS HAZARDOUS WASTE. 5. ANY DAMAGE TO EXISTING FACILITES DURING COURSE OF WORK SHALL BE RESTORED OR REPLACED AT CONTRACTOR'S EXPENSE. o 3 "6 i •'`; .�-.o SO" Aks v►' t. ry 41-. p h 4•1 o N Lu cc x W ri N Z W W _..J W J O I--- W 0- Q Fa— v) V) p Z Z O O 0 Ce O 2 W (n 1- U O DATE: 8/27/92 SHEET TITLE: SOUTH KING COUNTY DETACHMENT DEMOLITION SHEET NO. M-3 1 PUMP/MOTOR RELAY PPM 4100 riRIM 9000 PARTIAL BASEMENT FLOOR PLAN C ) 5 8" LOT DRAIN ® 18" BELOW ASPHALT GENERAL NOTES: 1. FOR TANK INSTALLATION DETAILS, SEE SHEETS M- 5 AND M- 6 . SD Li J -BOX MAIN DISTRIBUTION PANEL PANEL B EXISTING ESI PRINTER - J L ASPHALT EXISTING ESI CARD READER HOLD TIGHT ALONG WALL, ABOVE T -BAR CEIUNG ROUTE CONDUIT EXPOSED ALONG WALL CONDUIT ENTRANCE INTO BUILDING �1( EXTEND EXISTING ELECTRICAL CONDUIT, AIR AND WATER ONES TO NEW PUMP ISLAND LOCATION INDICATES CONDUIT ROUTING, NOT QUANTITY OR SIZE. SEE CONDUIT DIAGRAM SHEET M-5 EC A w 8 MONITORING WELL (2) TYPICAL c EC EC PIPING SUMP 50 15" 7 z CONCRETE BOLLARD (6) TYPICAL (SEE DETAIL THIS SHEET) FIELD VERIFY EXACT LOCATION OF PUMP ISLAND WITH OWNER LIMITS OF CANOPY (SEE \ DETAILS THIS SHEET) 2" SUMP/ INTERSTITIAL / VENT FX' Ti�iG \f FENCE 0 I 1 1 I LIMITS OF CONCRETE TRENCH SD 1 — v 0 Y TANK VENT EC EC A _U EC 7" WATER METER 1-1/2" BRINE RESERVOIR SENSOR X SD TANK GAUGE FILL RE -INSTALL CARD READER ON NEW PUMP ISLAND WHERE SHOWN DISPENSER TO BE LOCATED A MINIMUM DISTANCE OF 10'-0" FROM PROPERTY LINE LIMITS OF NEW CONCRETE SLAB 6" MIN WITH 6X6X10 GAUGE W.W M F. SLOPE 1/8" PER FOOT TOWARD CATCH BASIN INSTALL A 12,000 GALLON FIBERGLASS TANK, INCLUDING PIPING SUMP, VENTS, SUPPLY PIPING, ETC. LIMITS OF NEW CONCRETE SLAB. 6" MIN. WITH 6X6X10 GAUGE W.W.M F. SLOPE 1/8" PER FOOT AWAY FROM BUILDING 1\ I \ 1 10" SEWER LINE 0-1 15' BELOW ASPHALT SOUTH KING COUNTY DETACHMENT NEW WORK SCALE: 1/8" = 1'-0" FILE EDGES 611 -EXTRA STRONG GALV. PIPE CONC. FILLED SHED TO DRAIN CONC. BASE 1 FORM 18"0 AT =TOP ASPHALT PAVING CROWN CONC. G C PIPE BOLLARD DETAIL SCALE: NONE SUMP/INTERST1TIAL VENT TANK VENT 16'-0" RELOCATE EXISTING CARD READER TO LOCATION SHOWN. (4) 3/4" CONDUITS TO CARD READER MUST BE PULLED LIP THROUGH 5" SQUARE OPENING AT BASE OF CARD READER STAND. STUB -UP AND CAP. (SEE UNDERGROUND CONDUIT DIAGRAM SHEET M-5) M-3 M-3 STUB UP (2) SPARE 3/4 CONDUITS ATT THIS LOCATION STEEL PUMP ISLAND FORM (SEE NOTE) CANOPY COLUMN (2) TYPICAL INSTALL AIR & WATER REEL & SUMP PER MFR. HOLD-DOWN BOX BRAVO SYSTEMS, INSTRUCTIONS 200 SERIES MODEL 2510-3 PROVIDED BY CONTRACTOR PER MFR'S INSTRUCTIONS. PUMP ISLAND PLAN NTS NOTE: PUMP ISLAND FORM 12 GAUGE STEEL 13" H191-1,_"4'-0" WIDE WITH SEMI -CIRCULAR ENDS TOTAL LENGTH 16 -. FACTORY FORMED TO REQUIRED SHAPE. AS MANUFACTURED BY COXWELL'S (LOS ANGELES), AMFAB(MEMPHIS), OR APPROVED EQUAL GENERAL CONTRACTOR SHALL FURNISH AND INSTALL FORMS. AFTER PLACE- MENT, PRIME AND PAINT THE PERIMETER BLACK (BK -10 -SLG). DESIGN CONDITIONS: SNOW LOAD 25LBS/SQUARE FOOT WIND LOAD 80 MPH EXPOSURE B PROVIDE (2) HIGH PRESSURE SODIUM SURFACE MOUNT OUTDOOR FIXTURES, 150W EACH. CONNECT TO EXISTING LIGHT CIRCUIT. PROVIDE PHOTOCELL ON CANOPY TO CONTROL LIGHTS. 4'-0" 18'-0" 2'-O"MIN VENTS SIDE VIEW PUMP ISLAND 12'-0" COMMERCIAL ZONE PRODUCTS--,, �o TOWEL DISPENSER MODEL #DBWC PROVIDED BY CONTRACTOR. MOUNT TO CANOPY COLUMN ® 48" ABOVE ISLAND 18" MIN yExm1c READER { i 11 AIR/WATER T 7' �I I I I I CABINET PROVIDED AND INSTALLED BY OWNER NOTE: PROVIDE CANOPY AS SHOWN, COMPLETE W/CONCEALED GUTTERS, DOWNSPOUT, FASCIA, COLUMNS AND LIGHTS. MATERIAL TO BE FACTORY FINISHED. COLOR SELECTION BY OWNER. CANOPY DRAWINGS SHALL BE SUBMITTED AND APPROVED BY ENGINEER PRIOR TO MANUFACTURE. FRONT VIEW CONTRACTOR TO PROVIDE FOOTING DETAILS TO MEET DESIGN CONDITIONS. r -A CANOPY/PUMP ISLAND DETAIL wtb17. NTS DRAWN: R.L, C.H-S. DESIGNED: GMR s. v 0 Lu 0 - w_ APPROVED: NLL DESCRIPTION z 0 r) 5 w cr DATE O z DRAWN: R.L, C.H-S. DESIGNED: GMR s. v 0 Lu 0 - w_ APPROVED: NLL LU W -J 0 - CC J Z 0-- < 0 OO H V) o Z Z O = i -'O 0 Ce Z_ O = W 1- U w 0 0 DATE: 8/27/92 SHEET TITLE: SOUTH KING COUNTY DETACHMENT NEW WORK SHEET NO. M-4 BTINTLLTKPER O INSTALL ANR M-5 MFR'S INSTRUCTIONS (REFER TO SUMP NOTES BELOW) 3/4" CONDUIT FROM PIPING SMP TO LEAK DETECTION CONSOLE IN BLDG ELECT. ROOM CARRYING SEPARATE CONDUCTORS FOR BRINE SENSOR AND SUMP SENSOR. CONDUIT FOR REMOTE PUMP. SUMP SENSOR 3/4" CONDUIT FOR BRINE SENSOR FROM RESERVOIR TO PIPING SUMP. CAUTION: DO NOT PLACE STRAPS BETWEEN THE RIBS OF THE TANK, ONLY ON RIBS DESIGNATED BY STENCILLED ARROWS BRINE SENSOR BRINE RESERVOIR 3/4" CONDUIT FOR ELECTRONIC TANK GAUGE W/SEAL-OFF. RUN TO TANK MONITOR IN BLDG. 16"DIA. MANHOLE W/SKIRT TO WITHIN 6" OF TANK SHELL SPARE FILL SAMPLE WELL SAMPLE-�� WELL TERMINATE 2'-0" BELOW TANK 15,000 GALLON (OLYMPIA FLEET AND SUPPLY), 12,000 GALLON SOUTH KING COUNTY) UNDERGROUND FIBERGLASS STORAGE TANK. DOUBLE WALL W/ BRINE FILLED ANNULAR SPACE. THE WSP SHALL PURCHASE TANK, THE CONTRACTOR SHALL COORDINATE DELIVERY AND INSTALLATION WITH XERXES TANKS -51M- 12" MIN. TANK MFR. APPROVED BACKFILL SECTION A M-5M-5 SUMP NOTES: PIPING SUMP MUST BE WATERTIGHT. AFTER ALL PIPING AND CONDUITS ARE INSTALLED AND BEFORE BACKFILLING AROUND SUMP, THE SUMP SHALL BE TESTED AS FOLLOWS: 1. FILL PIPING SUMP FULL OF WATER. 2. VISUALLY CHECK FOR ANY LEAKS. 3. REPAIR ANY LEAKS. 4. AFTER ANY WATER LEAKS ARE REPAIRED, LEAVE THE WATER IN PIPING SUMP OVERNIGHT AND VISUALLY CHECK WATER LEVEL AND THE PIPING SUMP EXTERIOR FOR LEAKS. 5. IF LEAKS ARE DISCOVERED, REPAIR AND RETEST. 6. AFTER COMPLETION OF TESTING REMOVE ALL WATER FROM SUMP. SHEET NOTES: 1. SET TANK AT THE DEPTH REQUIRED FOR THE PRODUCT OR VENT LINE (3'-0" MIN.) 2. PRODUCT LINE TO HAVE A 1/4" PER 1'-0" SLOPE UPWARD FROM TANK TO DISPENSER. 3. CONTACT LOCATOR SERVICE BEFORE DIGGING. GASOLINE SUBMERSIBLE PUMPS RED JACKET "EXTRACTA" MOTORS ARE OF EXPLOSION—PROOF CONSTRUCTION. ELECTRICAL SERVICE INFORMATION NTS Model No. HP Volts Max Load Amps Locked Rotor Amps Winding Resistance (Ohms), Min. Max. BIk—Orange Red—Orange Blk—Red AGP75S1 3/4 200 250 6.5 22 3.6-4.1 9.6-10.6 13.2-14.6 "ALL INSTALLATION WORK MUST COMPLY WITH LOCAL CODE REQUIREMENTS. IF NO OTHER CODES APPLY, THE LATEST ISSUE OF THE NATIONAL ELECTRICAL CODE SHOULD BE FOLLOWED." 1. RED JACKET GASOLINE PUMPS ARE DESIGNED TO PUMP GASOLINE OR DIESEL FUELS ONLY HAVING A MAXIMUM SPECIFIC GRAVITY OF .95 AND MAXIMUM VISCOSITY OF 70 S.S.U. AT 60DEG.. GASOLINE PUMPS ARE NOT TO BE USED FOR GASOHOL BLENDS (A NEW CHEMICAL PUMP WOULD BE REQUIRED). 2. PUMPING WATER WILL OVERLOAD THE MOTOR AND DAMAGE THE BEARINGS. 3. RED JACKET GASOLINE PUMPS DESIGNED FOR CLASS 1 GROUP D ATMOSPHERE. T L TEMPORARY OR PERMANENT SHORING TO BE INSTALLED WHEN REQ'D. (TYP. ALL SIDES) SLOPE EXCAVATION TO ANGLE OF REPOSE IF SHORING IS NOT' REQ'D. (TYP. ALL SIDES) BRINE RESERVOIR TANK SENSOR GAUGE (SEP. CIRCUIT) M -51M-6 SAMPLE WELL (TYP. OF 2) M, .4,-5 5 SUMP SENSOR 18" t STAGE II VAPOR RECOVERY/VENT 4" SPARE (PLUGGED) SUBMERSIBLE PUMP 22" MANWAY W/ 3 4" NPT FITTINGS TYP. SUBMERSIBLE LINE SAMPLE SAMPLE 1 PUMP MONITOR WELL WELL PIPING SUMP BRINE RESERVOIR CONC. SLAB 6" MIN. THICKNESS TANK GAUGE SPARE (PLUGGED) M-1 M -i FILL z NEW TANK PLAN NTS COORDINATE PANEL LOCATIONS ON WALL WITH OWNER CONDUITS ONLY. NO PROBES. J—BOX AT PUMP ISLAND EXISTING CARD READER L_ DISPENSER W/LIGHT (4) 3/4" CONDUIT MUST BE PULLED UP THROUGH 5" SQUARE,OPENING AT BASE OF CARDREADER-STAND PULSER PULSER SPARE ). ) 115V AC DUPLEX OUTLET (SUPPUED BY CONTRACTOR) INSTALL PER RLM 9000 INSTRUCTIONS RED JACKET 9000 TANK MONITOR/ ALARM SYSTEM INTERFACE SIGNAL CABLE PPM 4100 PUMP/ -1 MOTOR RELAY I EXISTING (PANEL RE -USE (2) 3/4" CONDUIT TO CARD READER UNDERGROUND CONDUIT DIAGRAM NOTES: 1. EXACT CONDUIT LOCATIONS AT PUMP ISLAND SHALL BE AS DIRECTED BY OWNER. TERMINATE 6" ABOVE PUMP ISLAND, CAP AND PROVIDE PULL WIRE. 2. ALL CONDUIT TO AND FROM CARD READER SHALL BE RIGID STEEL. 3. ALL CONDUIT 3/4" UNLESS OTHERWISE NOTED. NTS t,,174'1 IPAN READELER L 1" SPARE LJ J STUB IN SPARE CONDUIT WITH PULL WIRE NEAR PANEL AND CAP PANEL LOCATION IN BUILDING SEE SITE PLANS FOR LOCATION 13,_0►� MIN O i QTANK 0 CV cc W 1-- Z W U J w CL 0 1-- Q- Q CL (` V) Z 0 0 10 2 W 0 CL Ci 0 w 0 0 DATE: 8/27/92 SHEET TITLE: UNDERGROUND STORAGE TANK DETAILS SHEET NO. M-5 [DESCRIPTION I cn z 0 FA w w 1— 0 d z 0 CV cc W 1-- Z W U J w CL 0 1-- Q- Q CL (` V) Z 0 0 10 2 W 0 CL Ci 0 w 0 0 DATE: 8/27/92 SHEET TITLE: UNDERGROUND STORAGE TANK DETAILS SHEET NO. M-5 CNI #236R 40.25" ROUND MANHOLE CONC. SLAB 2" SINGLE WALL FRP LINE. STUB UP INSIDE DISP. HOLD DOWN BOX AT ISLAND. STAGE II VAPOR RECOVERY LINE PIPING SUMP 4" VENT VALVE ASSEMBLY 1/4"/FT7 3/4" CONDUIT—PUMP CONTROLLER LEAK DETECTION SENSOR. W/ ENSOR (N BRINE RESERVOIR ERIES 2" SINGLE WALL FRP VENT LINE TO VENT STACK. USE 2" TELEFLEX CONNECTOR 4" MANWAY OPENING 1/16"DIA. VENT BLEED HOLE 2" OPW-53V FLOAT VENT STEEL PROTECTOR PLATES REMOTE PUMP W/4" SCH. 40 RISER 1\-11 1\1 2" MIN. PU P rTANK TOP PUMP CLEARANCE PER MFR'S REQUIREMENTS 2" TELEFLEX CONNECTOR SINGLE NNPETIALVEN(COMBIEWITHINTRSTI RESERVOIR VENT) 2" DOUBLE WALL FRP TO PUMP ISLAND. (2" PRIMARY PIPE SIZE) 2"X2"X3/4" TEE 2" BALL VALVE TRANSDUCER SUPPLIED BY OWNER CONDUIT FOR LINE MONITOR TO RED JACKET CONSOLE FLEXIBLE CONDUIT CONNECT MANWAY Sc PIPING SUMP PER MFR'S INSTRUCTION TANK BOTTOM NOTES: _ 1. CONTRACTOR TO VERIFY LENGTH OF SUBMERGED PUMP UNIT Sc I.D. OF TANK. 2. CONTRACTOR SHALL PROVIDE WATERTIGHT BULKHEAD FITTINGS ON ALL SUMP PENETRATIONS. TOTAL CONTAINMENTI`OR APPROVED EQUAL. 22"I.D. MANWAY PRIME W/ POLYKEN 927 1/2"NPT FITTING IN MANWAY FOR AIR REMOVAL DURING PETROTITE TESTING CAP OFF 4" SPARE OPENING W/PIPE PLUG REMOTE PUMP AND VENT n INSTALLATIONS AT PIPING SUMP END PREMIUM UNLEADED PRODUCT DISPENSER 1 1/2" PIPE RISER W/ DISPENSER 1 1/2" UNION (FURNISHED W/DISPENSER) ATTACH "CAUTION FIBERGLASS PIPE" TAG ON RISER BENEATH DISPENSER IMPACT SHUT—OFF VALVE POSITION SHEAR SECTION PER MANUFACTURER'S INSTRUCTION 3" CONTAINMENT COLLAR SUPPLIED W/BRAVO HOLD—DOWN BOX NTS TOP OF PUMP ISLAND HOLD—DOWN BOX BRAVO SYSTEMS 200 SERIES MODEL 2510-3 PROVIDED BY CONTRACTOR PER MFR'S INSTRUCTIONS. PROVIDE BULKHEAD FITTINGS FOR ALL PENETRATIONS. 3/4" CONDUIT (3) PLACES TYP. 2" TELEFLEX CONNECTOR FOR STAGE II VAPOR RECOVERY. CAP OFF INSIDE HOLD—DOWN BOX. 2" NOMINAL I.D. "TELEFLEX" FLEXIBLE CONNECTOR WITH 3"DIA x 36"LONG "FLEX PROTECTOR" MANUFACTURED BY AUSTIN ENGINEER GROUP OR APPROVED EQUAL. 11 J 3" DOUBLE WALL FRP 2" PRODUCT PIPING T 18" MIN. ALL SECONDARY CONTAINMENT FITTINGS SHALL BE (2) PIECE CLAMSHELL TYPE. --- 2"MIN. L4" MIN. 2" SINGLE WALL FRP VENT LINE TO VERTICAL STACK. 3" FIBERGLASS PIPE CLAMP FITTING DISPENSER INSTALLATION DETAILS NTS 12" X 12" CONC. DEADMAN. OLYMPIA FLEET AND SUPPLY FILL PREMIUM UNLEADED o 0 15,000 GAL FIBERGLASS TANK SOUTH KING COUNTY FILL PREMIUM UNLEADED 12,000 GAL FIBERGLASS TANK 1/8" THICK BRASS 'PLATE EMBEDDED INTO CONC. NEAR FILL. HOLE FOR BRASS NAIL. DRIVE 1" INTO CONC. NOTE: CONTRACTOR T9 FABRICATE TAGS AND STAMP. W%1/4 LETTERS AND NUMBERS. PRODUCT TAG LENGTH TO BE 24" LONGER THAN TANK (2 REQ.). CONSTRUCTION & INSTALLATION PER MFR'S INSTRUCTIONS NTS 1 1 1-1 I I ► 11� 11=11 I=111-111-111-111=1 11=111=111=!111=11 I-111- 1=1 El 11=I 1=1 i=l 11=I I H I 1=i i 1=1 11=I I I; 11- n M -5 M-6 TIE DOWN DETAIL EQUIPMENT LIST OWNER FURNISHED/CONTRACTOR INSTALLED GAS PUMP RED JACKET MODEL AGP75S1 3/4 HP 220V/1/60 OR APPROVED EQUAL UNDERGROUND STORAGE XERXES CORP., MODEL HYDROGUARD TANK DWT -TYPE= II. 8'0, 12,000 GAL (SOUTH KING COUNTY) DWT-TYPEIII. 10'0, 15,000 GAL (OLYMPIA FLEET AND SUPPLY) XERXES, WATERTIGHT SUMP OVERSPILL CONTAINMENT DISPENSER AIR/WATER REEL TANK MONITOR PUMP MOTOR RELAY OPW-1 OR EBW 5 GALLON CONTAINMENT SYSTEM. TOKHEIM MODEL 785 -1 -RC -APC DOUBLE HOSE SINGLE PRODUCT. INCLUDES TOKHEIM HOSE BREAKAWAY MODEL 697EBW, (2) 3/4" HOSES W/WHIP, (2) 100 SERIES VAPOR RECOVERY HOSE RETRACTORS, MODEL #100-6, (2) HEAVY DUTY, HIGH HOSE, 1-1/2" SQ. TUBING MTG POSTS AND HARDWARE FOR 3/4"x14' HOSES AND (2) OPW MODEL 11AP-B UNLEADED NOZZLES COXWELL CRUT-125-125 W/ELECTRIC HEATER & AUTOMATIC THERMOSTAT. 1/4" X 25' AIR AND WATER HOSES ON LOCKING RETRACTABLE REELS COMPLETE W/STAINLESS STEEL LOCKABLE TOP RED JACKET RLM 9000 SERIES MODEL 400-062-5RJ TANK MONITOR SYSTEM WITH RED JACKET RJ 400-098-5 INVENTORY SENSOR AND RED JACKET RJ LINE PRESSURE SENSOR KIT. INCLUDES RED JACKET SYSTEM START-UP RED JACKET MODEL 880-029 N.T.S. 4" 0 J PIPE SECTION TANK HOLD-DOWN STRAPS TANK BOTTOM ELEV. SCHED. 40 PVC CAP 12"DIA. OPW 104—MV MANHOLE W/9" SKIRT AND BOLT DOWN LID. OPW 633—TCP-4 ADAPTOR OPW 634—TT CAP GRAVEL FILL \-3/4" CONDUIT TO ALARM LOCATION SEAL OFF END. • 1/8" x 6" SLOTS CUT IN PIPE NOTE: PROVIDE 4" SCHED. 40 FACTORY LOTTED PVC WELLSCREENS MAX. 0.05 SLOTS ALTERNATE: " SCHED. 40 PV PIPE W/ CONTINUOUS SLOT EFFECT AS SHOWN IN DETAIL SAMPLE WELL M-5 M-6 SPARE r (2 TYPICAL) SPARE FILL NTS INSTALL 4" OIPEPLN NSPARE TANK OPEN— ING c /—\ (3) STEEL PROTECTOR PLATES /n\ • 11 OPW 633—TCP-4 ADAPTOR OPW 634—TT CAP 2," MIN. [4 MAX. t SPILL CONTAINER PRODUCT TAG AND NAME PLATE HOLDER (TYP.) 4" SCH 40 PIPE RISERS. TO BE PRIMED Sc WRAPPED. OPW-61 SOC DIMENSION PER MFR'S INSTRUCTIONS \U/ \ 1/ \U/ TANK CONNECTIONS AT FILL END NTS - HIGH LEVEL SHUT—OFF 0 N crN wl W 00 1--- z w w Q J w aQ �- o Q V) (NJ 1- a)V)o z o o z ct zcw w -� (/)c o Q z o% a. 1-= 0 w 0 0 DATE: 8/27/92 SHEET TITLE: UNDERGROUND STORAGE TANK DETAILS - DESCRIPTION I ul z 0 (75 w DATE d z 0 N crN wl W 00 1--- z w w Q J w aQ �- o Q V) (NJ 1- a)V)o z o o z ct zcw w -� (/)c o Q z o% a. 1-= 0 w 0 0 DATE: 8/27/92 SHEET TITLE: UNDERGROUND STORAGE TANK DETAILS -