Loading...
HomeMy WebLinkAboutPP - 14727 MACADAM RD S - BURK RESIDENCE - PERMITS AND PLANS14727 MACADAM RD S ASSOCIATED PERMITS 18-5-105 D18-0044 441t13444 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 766160-0242 Site Address: 14727 MACADAM ROAD S. TUKWILA, WA 98168 Suite Number: Floor: Tenant Name: MCHENRY DEVELOPMENT GROUP, LLC New Tenant? ❑ - Yes ❑ - No Property Owner's Name: BURK ANGELYN J+RICHARD C Mailing Address: P.O. Box 8290 Bonney Lake, WA 98391 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Ben Bernard Day Telephone: 253-840-9900 Company Name: Red Hawk Fire Protection Mailing Address: 801 Valley Ave NW suite D Puyallup WA 98371 benb@redhawkfp.com City State Zip E-mail Address: Fax Number: 253-307-994040 Contractor's City of Tukwila NICET III number: REDHAHF901QP Business License number: BUS -0994571 Total number of new/relocated devices or sprinkler heads: 23 Valuation of Project (contractor's bid price): $ 6785.00 Scope of Work (please provide detailed information): Design and installation of an Automatic Fire Sprinkler system in a new single family residence. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OICAUTHORIZED Signature: Plan Permit App.doc Date: Day Telephone: 8/22/14 TFD FP Form 8 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b;e-cov-( PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: te— /- Zed Type of Ins 'on: ...r tliti Address:/Y727 Suite#:///641410 Monitor: Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. COMMENTS: Corrections required prior to approval. /-ter— his /G-PAcif)-eX 44d'- for- 2 hs — pyer- ZQaps p L' 1721 (6,1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: M L. Date: 2 H $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 v r.. ..... INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /2e,d #neAudivAvt Type o ion: Contact Person: Hood & Duct: Address: Suite #:/4/7 a7 Special Instructions: Permits: Phone No.: proved per applicable codes. COMMENTS: Corrections required prior to approval. Gs oil 7'% rte-- 3o / 43 I lle-e2) -A) s t -epi 3Na; ,.,49fred_ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: — lit ---Z__ fri*5-3 Date: Wy07/1 Hrs.: A 0 n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Project Name: BURK RESIDENCE Location: 14727 MACADAM ROAD S. Drawing Name: 80134 FP210 Design Remote Area Number: Remote Area Location: Occupancy Classification: Commodity Classification: Density: Area of Application: Coverage per Sprinkler: Type of sprinklers calculated: No. of sprinklers calculated: Hydraulic Calculations for , , TUKWILA, WA 98168 1 MASTER BEDROOM Residential RESIDENTIAL 0.050gpm/ft2 900.00ft2 (Actual 185.79ft2) 256.00ft2 Pendent 2 In -rack Demand: N/A gpm at Node: N/A Hose Streams: 0.0 gpm gpm at Node: UG1 Type: Allowance at Source Total Water Required (including Hose Streams where applicable): From Water Supply at Node UG1: 26.32 gpm @ 37.074 psi Type of System: WET Volume of Dry or PreAction System: N/A Name of Contractor: Address: Phone Number: Name of designer: RED HAWK FIRE PROTECTION LLC. 1002 N. MERIDIAN, SUITE 100, BOX 227, 253-840-9900 Ben Bemard Authority Having Jurisdiction: CITY OF TUKWILA Notes: Calculation Date: 4/27/2018 WA$10TON STATE CERTIFICATE OF OOMMTINC1r Flit! PROTECTION $PRONIWI $YSTIM$ David Fox 0121-0409-C Level 3 Red Hawk Fire Protection, LLC REDHAWHF901QP �vnr.c( 7v� 04/27/18 •loss! we Oats M.E.P.CAD, Inc. AutoSPRINK 2018 v13.1.71.0 1 4/27/2018 1:33:33PM Page 1 Hydraulic Graph Job Name: BURK RESIDENCE Date: 4/27/2018 Remote Area Number: 1 Water Supply Summary Sheet Node: UG1 O O O O N od �/ O O O N - - _ _ - _ _ vailable Supply Static Pressure 150.000 P6.32 @ 149.964 37.074 lemand curve 1 ))IIII111 111111))1 111111111 111111111 1111111/1 111111111 II))II111 iiti irri litrTTT IIII Rii 0 0 0 CO O O oN oo _ pd - amssaJd 0 CO N N O (0 0 0 co O O O O 0) 4/27/2018 1:33:34PM AutoSPRINK 2018 v13.1.71.0 .oel `av3'd'3'W OO'W) 0'1./: VELA 91.0Z>INI2IdSolny Wdb£ E£ 6 8602/LZ/b O O A O W C11 O W O O N criO N 0 0 N 0 O 8 Pressure - psi O O O 0 O O N O 1111111111111111111 111111111 111111111 111111111 IIIIIIIII IIIIIIIII IIIIIIIII 111111111111111111 '6.32 @ 24.438 System demand curve vailable Supply Static Pressure 150.000 r 6.32 149.964 X N — _ - _ O O O 0 8 N O O 0 0 BOR Summary Sheet 6 :JegwnN eaJv eloweu 81,0Z/LZ/17 :alea 33N3GIS32i >1 If18 :eweN qor I 1 Summary Of Outflowing Devices Job Number: 80134 Report Description: Residential (1) Device Actual Flow (9Pm) Minimum Flow (gpm) K -Factor (K) Pressure (psi) C' Sprinkler S101 13.00 13.00 4.9 7.039 Sprinkler S102 13.32 13.00 4.9 7.388 14a Most Demanding Sprinkler Data d1� © M.E.P.CAD, Inc. AutoSPRINK 2018 v13.1.71.0 4/27/2018 1:33:35PM Page 4 Job Name: BURK RESIDENCE Remote Area Number: 1 Date: 4/27/2018 Supply Analysis Node Name(psi) Static Residual Flow (psi) @ (gpm) Available Total Demand (psi) (gpm) Required Pressure (psi) UG1 Water Supply 150.000 20.000 2200.00 149.964 26.32 37.074 Node Analysis Node Number Elevation (Foot) Node Type Pressure at Node (psi) Discharge at Node (gpm) Notes UG1 -3-0 Supply 37.074 26.32 S101 18-0 Sprinkler 7.039 13.00 S102 18-0 Sprinkler 7.388 13.32 UG2 -3-0 35.225 R3 1-0 24.657 R4 1-6 Gauge 24.438 R5 2-6% 23.965 R6 3-8% 19.159 R7 5-2'/z 18.497 P8 18-6 11.183 P9 18-6 7.589 (Aj ©M.E.P.CAD, Inc. ` AutoSPR INK 2018 v13.1.71. 4/27/2018 1:33:37PM Pape 5 SITE 10 20 SCALE 1"=20'-0" SYMBOLS CA 6" BELL LOCATION 3/4" WATER METE ® Without Comm Arlt As Noted it 1 Re ® Per The Attachl d Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance wlin current City standards. Acceptance is subject to errors arid omissions which do not authorize violations of adopted „inwards and ordinance:: The responsibility for the =equacy of design tens :totally with the designer. dditions, deletions :"'evisions to these drawings after nils date will void this acceptance and will require a resubmittal sof r viser.i drawings for subsequent approval. Final accepmrice is suoject to field test and Inspection by The Tukwila FifC Prevention Bureau. Date: 5-'X- I By: A -1"-s 51 1 J WILA FIRS DEPARTMENT" I lease call 206-5754407 and )Ye this Fire Permit No. nd exact address for shut - Lawn or restoraton approval. 6 14 CLAD PCV *FIow C b VC/144A" ) i'esir r tAY`e.k �ws�w t\ e- -ecr- w P t-et/4-11-' tiI I' TOF ELATE DEADER 5UB FLOOR TOP FLATE HEADER SUB FLOOR CA 63, mgr • E-6-1 MANUFACTURED TES a 24. C {TTP: !UN.O.; \\ i 5EE TRU55 EN( tNEERING FCR ADDITIONAL .INFORMATION) k Yom. XXX.X X Y t tXi T /y"{c • s 1 • i kl la' :N r- I HEADER HEADER STAIR WINDOW HEIGHTS CUT SECTION r.: • 2 4 SCALE 1/4"=1'-0" TO SYSTEM 114" MALE CPVC ADAPTER TYP 3� 2 X1%" REDUCING COUPLING TYP NIFOLD 1'h" SCH-40 STAINLESS STEEL DOLII. TEE — (BY OTHERS) 1'%" SCH-40 STAINLESS STEEL (BY OTHERS) -1 11=1 11=111 111=11 I-1 111 I H 1`I l i-1 I1 I �t ►11=, 11=1 I i -_i i=i 11=i i l i I—Ii 1 I I 11= g: U I i II 11=111-11 I� 1 1—1 1 I� 11-111 1 I 1=11 I-1 I I I_I � I„ �I l 11 i 11 1 1—Ili-111—ii—ill ill -1 1 1 1 E 4I i 1, �,i --roil i i l I 1=1 I I_i I I- 1Y2" UNDERGROUND (BY OTHERS) n 1211 11= I RISER DETAIL 0 - 1 2 SCALE 1 /2" 1'-0" RISER MATERIAL LIST ITEM # QTY SIZE DESCRIPTION 2 3 4 5 6 1 1 1 I''A AMES SERIES 20006 DOUBLE CHECK BACKFLOW 2 POTTER VSR WATERFLOW SWTICH 6 POTTER PBA246 ELECTRIC BELL - 6hd SPARE HEAD CABINET CONTAINING: V2 ARGO PRESSURE GAUGE 1 TEST AND DRAIN SPARE HEAD CABINET QTY SIZE DESCRIPTION 4 1 1 1 GL4906 RESIDENTIAL SPRINKLER HEADS 155° TY5238 CONCEALED SPRINKLER HEAD 286° SPRINKLER HEAD WRENCH FOR GL4906 SPRINKLER HEAD WRENCH FOR TY5238 „X -X BOD SWAY BRACING PIPE HANGER FLEXIBLE COUPLING RIGID. COUPLING SCREWED CAP SCREWED PLUG HYDRAULIC NODE LINE PIPE DESIGNATION LABEL MAIN PIPE DESIGNATION LABEL SCOPE OF WORK RED HAWK FIRE PROTECTION, LLC (RHFP) WILL PROVIDE ONE WET PIPE AUTOMATIC SPRINKLER SYSTEM TO PROTECT THE NEWLY BUILT SINGLE FAMILY RESIDENCE. RHFP WILL START WORK AT NEW 1W UNDERGROUND SUPPLY IN GARAGE. ALL AREAS PROTECTED BY WET SYSTEM MUST BE MAINTAINED BY OTHERS ATA MINIMUM 40°F TO PREVENT FREEZING. -' GATE VALVE-N.R.S. (GV) OS&Y GATE VALVE (OS&Y) FLOW SWITCH (FS) ELECTRIC BELL WATER MOTOR GONG (WMG) CHECK VALVE FIRE DEPARTMENT CONNECTION (STANDARD) FIRE DEPARTMENT CONNECTION (FLUSH) PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT. ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT WIRING AND SERVICES CEILING AND WALL REMOVAUREPLACETO FACILITATE THE INSTALLATION OF THE SPRINKLER SYSTEM. PER NFPA 13D (2016), CITY OF TUKWILA. MASTER BEDROOM (FP 2.10)' WET SYSTEM RESIDENTIAL HAZARD DESIGN DENSITY: 0:05 GPM / 2 MOST DEMANDING HEADS FIRE DEPARTMENT CONNECTION (SIDEWALK) EXISTING FIRE HYDRANT NEW FIRE HYDRANT POST INDICATOR VALVE (PIV) THRUST BLOCK FLANGED CONNECTION GLOBE VALVE ANGLE VALVE EXISTING SPRINKLER PIPING NEW SPRINKLER PIPING BY OTHERS NEW SPRINKLER PIPING BY RHFP CENTERLINE OF PIPE TO BOTTOM OF DECK ;a- X -x BB • CENTERLINE OF PIPE TO BOTTOM OF BEAM OR JOIST * X -X FF CENTERLINE OF PIPE ABOVE FINISHED FLOOR WATER FLOW INFORMATION HAS BEEN PROVIDED BY MIKE CUSICK, P.E. SENIOR PROGRAM MANAGER FORTUKWILASEWER/WATER STATIC PRESSURE: RESIDUAL FLOW: 150 PSI 2200 GPM RESIDUAL PRESSURE 20 PSI GENERAL NOTES DRAWING:INDEX 1. SPRINKLER SYSTEM DESIGN PER NFPA#13D 2016. 2. ALL MATERIALS SHALL BE NEW AND UL AND/OR FM APPROVED. 3. FIRE SPRINKLER SYSTEM TO BE INSTALLED, BRACED AND TESTED IN ACCORDANCE WITH NFPA#13DAND SPECIFICATIONS. FP 0.10 FP 2.10 SITE PLAN AND NOTES FIRE SPRINKLER PLAN 4. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS IT IS THE OWNERS RESPONSIBILITYTO PROVIDE HEAT THROUGH OUT THE WET PIPE SPRINKLER SYSTEM AREAS AND IN ENCLOSURES FOR DRY PIPE, DELUGE AND OTHER: TYPES OF VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS: 5. FIRE PROTECTION CONTRACTOR SHALL NOT BE RESPONSIBLE FOR THE ABILITY OF THE STRUCTURE TO ADEQUATELY SUPPORT THE FIRE SPRINKLER SYSTEM OR ANY APPURTENANCES THEREOF. 6. ALL ELECTRICAL, PAINTING OF PIPE, FURRING, CUTTING OR PATCHING TO BE BY OTHERS. Seattle Jungto Socie Southcenter Comrnunity Baptist RED HAWK FIRE PROTECTION, LLC 801VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 Fax (800) 591-4382 WA CL# REDHAHF901OP NICET Stamp sv WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Fox 0121-0409-C Level3 Red Hawk Fire Protection, LLC REDHAWHF901 QP 77„ 04/27/18 Signature Date Expires 12131118 Approvals Required CITY OF TUKWILA OWNER /ARCHITECT Revisions Contract With: MCHENRY DEVELOPMENT GROUP, LLC P.O. BOX 8290 BONNEY LAKE, WA 98391 SiteSuper: PATRICK MCHENRY Phone: 0.25) 505-3313 Contract Name: BURK RESIDENCE 14727 MACADAM ROAD S. TUKWILA, WA 98168 Drawing Title SITE .PLAN AND NOTES Key Plan Date: Job Number: Designer: Building Permit: April 30, 2018 80134 Ben Bernard Drawing No. FPO:i Q PAID f' ! — 2018 TUKWILA FIRE �cc x/9.5U 11110 Mr...7 FOUR #10 x11/2" SHEET METAL SCREWS FIG. 511 HANGER 1. 2" PIPE, MAXIMUM Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft2) 0.05 for 900.00ft2 (Actual 185.79ft2) TOTAL HEADS FLOWING 2 K -FACTOR 4.9 TOTAL WATER REQUIRED 26.32 TOTAL PRESSURE REQUIRED 37.074 BASE of RISER (gpm) 26.32 BASE of RISER (psi) 24.438 SAFETY MARGIN (psi) +112.890 (75.3%) STORAGE CPVc, STEEL - HANGER FIG. 511 MINIMUM 2x6 x 6" LONG FILLER BLOCK, ATTACHED TIGHT TO TOP FLANGE. \LCC 4EQVE FP 0.10 OPEN TO BELOW FOYER OPEN TO ABOVE FOUR #10x1W\ SHEET METAL SCREWS 'T'FEG. `rFEC. '' 'FE! (. Response SIN I K -Factor BEDROOM 2 CPVC, STEEL - HANGER FIG. 514 MINIMUM 2x6 x 6" LONG FILLER BLOCK, ATTACHED TIGHT TO TOP FLANGE. OFFICE FIG. 510 HANGER FOUR #10 x 11/2"--/ SHEET METAL SCREWS: MAIN FLOOR FIRE SPRINKLER PLAN 0. 2 SCALE 1/4"=1'-0" PIPE UPPER FLOOR FIRE SPRINKLER PLAN CPVC, STEEL - HANGER FIG 510 FOUR #10 x 11/2' SHEET —: METAL SCREWS FIG. 513 HANGER \ MINIMUM 2x6 x 6" LONG FILLER BLOCK, ATTACHED TIGHT TO TOP FLANGE. CPVC, STEEL - HANGER FIG. 513 HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS N- O OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13D, 2016 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) NOMINAL PIPE SIZE (IN. ) PIPE TYPE 3/4 1 1 114 1 1/2 2 21/2 3 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 Caution: It is important that the insulation be installed tight against the joists. In unheated areas, any spaces or voids between the insulation and the joists causes the water in the fire sprinkler piping to freeze. SCALE 1/4"=1'-0" GENERAL NOTES 1. MAIN CEILINGS TO BE 9-0 AFF. UPPER CEILINGS TO BE 8.0 AFF. UNLESS NOTED OTHERWISE. 2. PIPE FROM RISER AND MAIN TO BE 1'A" CPVC, ALL OTHER PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED. WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 Fr PER SECTION 8.6.2 OF NFPA 130 (2013) AREAS MARKED WITH HATCH 5. ALL ROOMS WITH SPACED AT 16'-0" X 16'-0" Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. INSULATION DETAILS NTS Sprinkler Legend Symbol r; (. Response SIN I K -Factor Size Temperature Finish Spacing MINIMUM 2x6 x 6" LONG FILLER BLOCK, ATTACHED TIGHT TO TOP FLANGE. OFFICE FIG. 510 HANGER FOUR #10 x 11/2"--/ SHEET METAL SCREWS: MAIN FLOOR FIRE SPRINKLER PLAN 0. 2 SCALE 1/4"=1'-0" PIPE UPPER FLOOR FIRE SPRINKLER PLAN CPVC, STEEL - HANGER FIG 510 FOUR #10 x 11/2' SHEET —: METAL SCREWS FIG. 513 HANGER \ MINIMUM 2x6 x 6" LONG FILLER BLOCK, ATTACHED TIGHT TO TOP FLANGE. CPVC, STEEL - HANGER FIG. 513 HANGERS - PIPE HANGERS SHALL BE SIZED, SPACED AND INSTALLED AS REQUIRED BY NFPA STANDARDS N- O OTHER PIPING AND/OR DEVICES ARE TO BE ATTACHED TO THE SPRINKLER PIPE HANGER SYSTEM UNLESS THE HANGER HAS BEEN SPECIFICALLY DESIGNED FOR THE ADDITIONAL LOADING. THIS CONTRACT DOES NOT INCLUDE ANY MATERIAL OR DEVICES TO IMPROVE THE STRUCTURAL STRENGTH OF THE BUILDING TO ENABLE IT TO CARRY THE LOAD OF THE FIRE PROTECTION SYSTEM. - SEE DETAILS ON THIS SHEET FOR THE SPECIFIC HANGER ASSEMBLIES USED FOR THIS INSTALLATION. NFPA 13D, 2016 Edition Table 9.2.2.1 MAXIMUM DISTANCE BETWEEN HANGERS (ft - in) NOMINAL PIPE SIZE (IN. ) PIPE TYPE 3/4 1 1 114 1 1/2 2 21/2 3 CPVC 5-6 6-0 6-6 7-0 8-0 9-0 10-0 Caution: It is important that the insulation be installed tight against the joists. In unheated areas, any spaces or voids between the insulation and the joists causes the water in the fire sprinkler piping to freeze. SCALE 1/4"=1'-0" GENERAL NOTES 1. MAIN CEILINGS TO BE 9-0 AFF. UPPER CEILINGS TO BE 8.0 AFF. UNLESS NOTED OTHERWISE. 2. PIPE FROM RISER AND MAIN TO BE 1'A" CPVC, ALL OTHER PIPE TO BE 1" CPVC UNLESS NOTED OTHERWISE. 3. SPRINKLERS OMITTED FROM ALL CLOSETS MEETING THE REQUIREMENTS OF SECTION 8.6.3 OF NFPA 13D (2013) AREAS MARKED. WITH HATCH 4. SPRINKLERS OMITTED FROM ALL BATHROOMS UNDER 55 Fr PER SECTION 8.6.2 OF NFPA 130 (2013) AREAS MARKED WITH HATCH 5. ALL ROOMS WITH SPACED AT 16'-0" X 16'-0" Caution: For areas having temperatures of 0°F (-18°C) or lower, an additional batt of insulation covering the joist and the fire sprinkler piping should be used. If this is not done, freeze -ups can occur in the sprinkler piping. INSULATION DETAILS NTS Sprinkler Legend Symbol Manufacturer Type Response SIN I K -Factor Size Temperature Finish Spacing Discharge Quantity IN N. Globe Pendent Quick GL4906I 4.9 'J _ 155°F Bronze 16 X 16 . 13 GPM 23 Total = 23 RED HAWK FIRE. PROTECTION, LLC tfroo Affe 801 VALLEY AVE NW, SUITE D PUYALLUP, WA 98371 PHONE: (253) 840-9900 FAX (800) 591-4382 WA CL# REDHAHF901 OP NICET Stamp WASHINOTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Fox 0121-0409-C Level 3 . Red Hawk Fire Protection, LLC REDHAWHF901QP 1 1 1 1. 1 ■ ■ • 1 1 1 ■ � 1 77:o?'G 04/27/18 ,per, SIgnatun _ Dat• 12/31/18 a Approvals Required CITY OF TUKWILA OWNER /ARCHITECT Revisions Contract With: MCHENRY DEVELOPMENT GROUP, LLC P.O. BOX 8290 BONNEY LAKE, WA 98391 SiteSuper: PATRICK MCHENRY Phone: (425) 505-3873 Contract Name: BURK RESIDENCE 14727 MACADAM ROAD S. TUKWILA, WA 981.68 Drawing Title FIRE SPRINKLER PLANS Key Plan Date: Job Number: Designer: Building Permit: April 27, 2018 80134 - Ben Bemard Drawing No. FP2i 0