HomeMy WebLinkAboutPP - 13405 MACADAM RD S - SARA VISTA LOT 8 RESIDENCE - PERMITS AND PLANS13405 MACADAM RD S
ASSOCIATED PERMITS
05-S-048
FURR OUT TO
HIDE SEAT CUT
VENT BLKG
MTL GUTTER
ON Ix8
CEDAR FASCIA
BEAM PER PLAN
(CRETE PAD
4" PAST COLUMN
SES
FIN GRADE
12
4f—
7+1
BAFFLE TO MAINTAIN
I" CLR BETWEEN
INSUL 4 ROOF SHTG
VENT BLKG
MTL GUTTER
ON 1x8
CEDAR FASCIA
EDGE NAILING
2x12 NAILER
w/4-16dg16" O.G.
2X12 CROSSCUT
FOR VENTILATION
2x12 RFTRS, 24"oc
TRUSSES, 24"oc
12
1/2" GWB
R-30 INSUL
w/ 4 MIL VB
BEAM PER
PLAN
HDR PER
PLiT� r----
�fil NI HI III III HI
II_]IL_-ALE
2x6 STUDS
16"oc
R -2I INSUL
LINING
4" DIA. TIGHTLINE'"
TO STORM
4" DIA. PERF PERM
FTG DRAIN
8" FON WALL
6 MIL VB
HPDR PER
1J5UL4.Ttot,1 7; 13E -1-01.)-Mc)
over& SPR) f1)- Les- PI P1 N
BY
0-ri-ie-42.
-R-38 INSUL
w/ 4 MIL VB
1/2" CCB
WINDOW imp -3
INSUL
3/4" PLY ON
JOIST PER PL: M\1
PLYWOOD ROOF
TO FLOOR
DINING
3/4" PLY ON
JOIST PER PLAN
11E-BLKG
BEAM, POST, FTG 4
ANCHORS PER PLANS
SED -4
12
nuu'I,uhIu ,/-
{
HDR PER
PLAN
R-21 INSUL— -
BLKG
2x6 STUDS
16"oc
KITCHEN
R-30 INSU
w/4 MIL VB
0
.UUU
z
z
DE
UIL1D1NG SECTION
III ME-rEf2- $1' on -le
C'is f'Si-5TAT1G- AVAILABL>r..)
434. S
1 f
12`(Doi— t
POLY tk.
tsy 0, HERS
•-• ,
SIRE s .rKuJI .`
RIg- St✓ PLAN
tCP
f1(
I D/1111 -1 —130R
5 /36 _,=1BI5LST
LIVING
CARPET
9
BLt
I� Mar ARG -A
CVALIt_TEp
50"x14"
4:Z Pt-rci4
V)
3
Y
H.S.
11
ra¢' 5° XO
f
oSTS -
ELEV. 'B'
SEE ROOF :\
- PLAN =,8"
FORM s
t J ST
11.111011111 ,111
I` 1
SE
CARP
42"x32"
W
V
10
c
I/2"
FAN
"D9
5'-4 1/2"
-II"
3' -II 1/2"
5'-9"
5'-8"
5013P
2
SD
0
0 BP
a_
tn.
2. 4i
C
,ACC 45
4P
S4P
re
1.14
CARPET OP. CATH
5D
0 -; i /`\ I
�6r8L. 23<4 WALL
2'-2"
OR FLUE(' -8 1/2"
FLUE
5'-1 1/2"
()SD
FRAME WALL
FLAT FOR 12"
LINEN SHELF
v
TD. 2'
4(2x
j 4 x I0
UPPER FLOOf- LAN
2°5° FIX
TSG
DEY
E] . 'A'
f' 24
0
L
r
2 LAYERS
1/2" OSB
o/ DECK
3'-0"
/
1" FIRE SPRINKLE
R15Eg - SEE
!ETA IL.
6 3/4111 "CSL Cpti7F'FED)
10'-3"
E OF
DR
2 CAR GARAGE
4" CONC. SLAB - SLOPE 3"
TOWARDS O.H_ DOORS
11
\ OPT II
2811
(5) 2X4. ---4i
-I
/ 8\ 16-1°OH GAR DR
(\ /)
• DOOR BETWEEN HOUSE 4 GARAGE TO BE SOLID CORE ul/SELF _
CLOSING HINGES. (DOOR MIN. I-3/8" THICK) 1
• 5/8" TYPE 'X' G.W.B. ON ALL HOUSE/GARAGE SUPPORTING
WALLS, POST, 4 BEAMS. (2) -LAYERS a CEILING WHERE +++++I
TRUSSES OR FRAMING GREATER THAN 16" O.C.
3 1/8"x12 °x20`+
4111111.111111111011. 41111b MMINII11111111.111. IMP 1=O1111111.111111M .1116 01111111111111011111•1111 41111111111111101111••• d11111 411111111111/1•111111• 0111. 111•111•1•111111111•111
MAIN FLOO PLAN
AREA SUMMARY:
MAIN FLOOR = 1030 SQ. FT.
UPPER FLOOR = 914 SQ. FT.
TOTAL
GARAGE
NOTES
1944 SQ. FT.
516SQ. FT.
U)
cc
Vli
LU
3
th
N
a-
au)
I0RA10
VALVE
UNisTRtifl
MoWJT ►+►►►� r
7
I AD
BLE CNS K
.t- V,4LoU 'VE ASSEMBLY
0
cPvG FEMAL E
ADAPTER
TeL NIPPLE
Y P I GA L 3)
7-----PRES5LIRE C�AUC�E
�-WQTE'RFLoLnl SWITCH
k.STEEL
9O ELL
DCVA To E. MOU NTE2
No Less THAt4 1-0"
orz NO MOR -TI-IAN
,gyp ovE FLOOR
WITH ALL PORTS ACGESSI$LE
lug
COMiEI N GD FIRE AND DdM�ST-I�
WAT SUPPL'1' FROM 5TReeT 13Y of J RS
RISER DETAIL
NTS
CPVC HANGERS/RESTRAINERS
TYPICAL APPLICATIONS
tNCDN►Dlta TED
HANGER
APPUCATION
1
RESTRAINER
APPUCATION
FlG. 22
1. The design is based on N.F.P.A. 13D and is hydraulically
calculated for the most demanding 2 fire sprinklers.
2. Maximum spacing for residential fire sprinklers is 16' x 16'
and 8'-0" maximum from walls. If required, dry fire sprinklers
to be spaced at 225 sq. ft. maximum and located 7'-6"
maximum from walls.
3. Pipe and fittings to be CPVC unless noted otherwise.
4. Pipe size to be 1". -
5. Pipe hanger type and spacing to be in accordance with
N.F.P.A. 13D and the CPVC piping specifications.
0
FIG. 23
ALL TOLCO HANGERS / RESTRAINERS
USED WITH CPVC PLASTIC PIPE
CONFORM TO NFPA 13, 13R, & 13D.
APPROVED FASTENERS ARE
FURNISHED BY MANUFACTURER
WITH FIG. 22, FIG. 23 & FIG. 24.
BAND
HANGER .
FIG. 24
796 E. HARRISON STREET CORONA, CALIFORNIA 91719
(909) 737-5599 FAX (909) 737-0330 (510) 791-2632
FIG. 25
SURGE
RESTRAINER
1111
1
ACC1PTI!D
(-3
Without Comrnente
As Noted In Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fre
Prevention Bureau for conformance with current city.
standards. Acceptance is subject to errors and
omissions which do not authorize violations of adopted
standards and ordinances. The responsibility for the
:adequacy of design rests totally with the designer.
l Additions, deletions or revisions to these drawings after
j '. his date will void thi acce tance and wit;
require a
1 resubmittal of revised drawings for subsequent approval.
Final acceptance is subject to field test and Inspection by
The Tukwila Fire Prevention Bureau.
Date: '11D-4 6S By: _c/
WKWILA FIRE DEPARTME. 1
Please call: 575.4407,
and give this job
No.OSS 041
and exact address for shut*
oown or restoration aporovi ;
CRESENT HOMES
P nkler, /ryc
stc
Ta r zi R
s 9y
�-04-
•ig��'L.=ZGr)
'� Signature atm
jam► A -
0,.;4.4%
0
N
on spriw C
;.r,,.. ~rh"o49hDeceVle'
1" LOOP
SPRINKLER HEADS
Sym
Type
Model
K -Factor
Temp
Canopy
•
RESIDENTIAL PENDENT
RELIABLE RFC43
4.3K
1650
CONCEALED - WHITE
Quan
4
i
4
JOB: SARA VISTA LOT NO. 8 RESIDENCE
13405 MACADAM ROAD SOUTH, TUKWILA, WA
SCALE: 1/4" = 1'-O"
DATE: 3-17-2005
PARCEL NO. 261320-0158
DRAWN BY: TR
REVISED:
CONTRACTOR: WASHINGTON FIRE SPRINKLER, INC.
1 3217 MERIDIAN EAST # C, EDGEWOOD, WA 98371
Project Total
STATE LICENSE NUMBER:
17 WASHIFS012PG
DRAWING NUMBER:
1 OF 1