HomeMy WebLinkAboutPP - 13425 MACADAM RD S - SARA VISTA LOT 6 RESIDENCE - PERMITS AND PLANS13425 MACADAM RD S ASSOCIATED PERMITS 04-5-200 CPVC HANGERS/RESTRAINERS TYPICAL APPLICATIONS INCORPORATED HANGER APPUCATION i RESTRAINER APPUCATION FIG. 22 FIG. 24 FIG. 23 ALLTOLCO HANGERS / RESTRAINERS USED WITH CPVC PLASTIC PIPE CONFORM TO NFPA 13, 13R, & 13D. APPROVED FASTENERS ARE FURNISHED BY MANUFACTURER WITH FIG.22, FIG. 23 & FIG. 24. FIG. 25 SURGE RESTRAINER 'BAND Etki HANGER 796 E. HARRISON STREET, CORONA, CALIFORNIA 91719 (909) 737-5599 FAX (909) 737-0330 (510) 791-2632 NOTES 1. The design is based on N.F.P.A. 13D and is hydraulically calculated for the most demanding 2 fire sprinklers. 2. Maximum spacing for residential fire sprinklers is 16' x 16' and 8'-0" maximum from walls. If required, dry fire sprinklers to be spaced at 225 sq. ft. maximum and located 7'-6" maximum from walls. 3. Pipe and fittings to be CPVC unless noted otherwise. 4. Pipe size to be 1" unless noted otherwise. 5. Pipe hanger type and spacing to be in accordance with N.F.P.A. 13D and the CPVC piping specifications. MAIN FLOOR PLAN 1/4"=lI-0II AREA 8UMNA Y: MAIN FLOOR UPPER FLOOR TOTAL GARAGE ▪ 1155 SQ. FT. = 1043 SQ. FT. ▪ 2198 SQ. FT. = 445 SQ. FT. PRA IN VALVI: „ I L.4- 2_.x.4 UNIsrRUri hoUNT Cpv . FEMALE ADAPTER STEoL NIPPLE L.TYP I GA L 3) �, PRESSURE GiA�GIE -WATERFLOW SWITCH 1t,- STEEL a 9D ELL ® CDOL3LE CI4SCK. I ' VALVE ASSEMBLY )CVA Ta E. Mol»NTr` P No Less THAM l=o” zorz No MORE -THAN 5Lo" N la i ,ove FLOOR cJI i-rH ALL PORTS Acce551'8LE CoM61 N EI7 FIRE AND DdMET'IG WATER SUPPLY FROM STREET RISER DETAI NTS WBC424130L 53061 �PI I 1 A/R-FB3 1E- 0 E- O O AIN' I n F 60001101100 06 513 gY 011-IRS UPPER FL. lE. .% GIRDER TRUSS 12 COMPOSITION ROOFING TRUSSES a 24" O.C. R-38 BLOWN -IN INSULATION - IIJSULAT1ON To SE TENTED OVER FIRE SPRIW KLER PIPING LY OTHERS vENTED BLOCK W/ BAFFEL \\ i METAL GUTTER T-0" MONO W/ 3'-0" CANT F 00 MAIN FL. fE U1 30 DA) -I•-- j321RST N KITCHEN 41-0" 31-3 1 3 1/2" -0" 384 RS. C (2) 2X6 4> 5'-8 1/2" 4'-411 MAIN FLOOR l 3'-0" ON lb 4'-0 3/18" m BEAM PER PLAN BEAM PER PLAN BATH 34" T4G PLYWOOD SUBFLOOR----,,k NALL 543" G.W.B. TYP ON CEILINGS e MUSSES 15ED 3 FLOOR JOISTS PER PLAN 3/4" T46 PLYWOOD SUBFLOOR---_,N\ ANCHOR POSTS g TOP 4 BTM. A-35 4, ALL POSTS (TYP.) LEAM PER PLAN 1(.40* FELT UNDER ALL POSTS - _ 1/2" G.W.B. TYP ON CEILINGS e TRUSSES KI TCI-4EN FLOOR JOISTS PER PLAN r\ III[llititlob R-30 INSULATIO 6 MIL BLACK VAPOR BARRIER BUILDINCx SECTION ('A' ELEV) 3 I/O" x 10 I '�`d�L6 N H.5. 0 H.S. 5'-3" MATCH DINING/LIVING OPENING HEIGHT WING CARPET x M -3 1/2" 3 1/2"X9" W/ ONE TOP m PLATE _I rx" 1(3)2x4 (3)2x4 cn N 11-10" SD 3'-6" C e 0 '1- W 41-4" &CSC ZF1RE SPRINKLER RISE SEE DETAIL ISI E GREAT . I CARPET • 0- LR' NT DI CT VE GA 1' FIRE/LAC Rr1 LND CNYL Jv . vros 4," I— -—If 1- 1DRYER ] IL ail II71-7-1l V.T.O.S. L -JJ jCL (5) 2x6 E OF FLOOR ABOVE (3)2x (3)2x4 w C H.5 01 C r 5. m 0 E OF WALL AB VE H.S. 30 CI ISI 4111111 41111•11.0111111.•••• 6°5XO Pr -3 0 c4 L'B' (3) 2X4 OVERHANG — PLYWOOD I" FOR DRYWALL LINE OF LOOR ABOVE 5'-5 I/2" GAS FURN 2 CAR GARAGE 4" CONC. SLAB - SLOPE 3" TOWARDS 0.1-1. DOORS INSTALL 5/8" TYPE 'X' GWB ON CLC, WALLS, AND BEAM 2 LAYERS AT 24"oc FRMG 9 9 �_=z` 3 OPT. t (5) 2x4- . 0 C e) 1601° OH GAR DR 4x12 DF42 SSW 111111111 UPPER FLOOR PLAN 101100100111116 101111010011111MB Aft 111111100•00•1116 06 1/4".11-0" EL. 'B' (3) 2X4 —011001101111•10—l.. 3 I/411=11-0" S rl a p4- Lor (A 13435 M4cAd' - �ICK�t,�i W19 98/(4 9 0 Z2Oo "A" 3C4r _ID' P L-_ - - - !i. Ca��% .rti FTE SPM 014•Lelz• RL. E R.- see. 4 if 6 2X6 STUDS 016" O.C. W/ R -2I INSULATION 2X4 TRT'D MUD SILL W/ 5/0"4' X 10" ANCHOR BOLTS 48" O.C. 0 r . -1 - ALL FOOTINGS TO BEAR ON UNDISTURBED SOIL - MIN. 2000 lbs. P.S.F. ✓'e 5 Ca a+ 1 -1 -01A -e: 12" x154)=0' - PaLY UG. BY o -rt -t E f=s, ,'e Cvato t dvai .� r.ial.. I:: cx iumsTeA 51' orI.1 Without Comments / ❑ As Noted In Red ❑ Per The Attached Letter 4i4 D CYc<,�1 These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions t'o these drawings after this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspectio The Tukwila Fire Prevention Bureau. Date: 9/2.9 0-( By: it i,510 dv4:•'- 2�d c. ayG �Ii ;S9py rt..e rwcwILA FIRE DEPARTMEN1 Please call: 575-4407 and give this job and exact address for shut - dawn or restoration approval, FOR ktbugh SEP 2 7 tot 112 RI SER I'I LOOP SPRINKLER HEADS JOB: SARA VISTA LOT NO. 06 RESIDENCE 13425 MACADAM ROAD S., TUKWILA, WA. Sym Type Model K -Factor Temp Canopy Quan 0 RESIDENTIAL PENDENT TYCO LFII 4.2 K 160° CONCEALED — WHITE 18 SCALE: W/4" = 1'-O" PARCEL NO. 2613200156 DRAWN BY: TR DATE: 9-17-2004 REVISED: CONTRACTOR: WASHINGTON FIRE SPRINKLER, INC. 321.4" MERIDIAN EAST # C, EDGEWOOD, WA 98371 STATE LICENSE NUME['.2: _- WASHIFS012PG DRAWING NUMBER: I 1 OF 1 Project Total is