HomeMy WebLinkAboutPP - 14415 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS14415 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS D19-0377 City of Tukwila Allan Ekberg, Mayor Fire Department Jay C. Wittwer, Fire Chief February 26, 2021 Maxwell Burke Attorney Cairncross & Hempelmann MBurkee.Cairncross.com Re: Exception for D19-0377 Permit Conditions Requiring a Fire Sprinkler System at 14415 TUKWILA INTL BLVD Hello Mr. Burke, I have reviewed your request for a Fire Sprinkler System exception, the project scope for D19-0377, and the Fire conditions that were required. Due to the Fire Sprinkler requirements in TMC 16.42.090B (Existing Buildings) and TMC 16.42.050A (Where Required), and the reasons given for the exception, there is no basis to not require a Fire Sprinkler System for D19-0377. Pursuant to Tukwila Municipal Code 16.42.120, this letter (via email) serves as written notification that your request is denied. Respectfully, Ben Hayman 1 Battalion Chief Tukwila Fire Department 1 Fire Marshal Email: Ben .Hayman@Tu kwila WA.gov cc (email): City Attorneys Daniel Kenny and Andrew Tsoming Tukwila Fire Marshal's Office • 6300 Southcenter Blvd., Suite #209 • Tukwila, Washington 98188 Email: FireMarshal@TukwllaWa.gov • CH&CAIRNCROSS&HEMPELMANN ATTORNEYS AT LAW 524 2nd Ave.. Suite 500 office. 306.587.0700 Seattle. WA 98104 fax 206.5872308 v,ww.ca i rncros s.ccrn March 12, 2021 VIA EMAIL Christy O'Flaherty City Clerk City of Tukwila Christy.OF1aherty@TukwilaWA.gov TukwilaCityClerk@tukwilawa.gov RECEIVED MAR 12 2021 CITY OF TUKWILA CITY CLERK Re: Notice of Appeal of Fire Marshal's denial of exception request re Permit D19-0377 Dear Ms. O'Flaherty: Pursuant to TMC 16.42.150, my office fifes this Notice of Appeal on behalf of our client, David Malik. TMC 16.42.150 requires the following information regarding the Appellant: David Malik 26220 116th Ave. SE, 201 Kent, WA 98030 206-841-3355 Mr. Malik appeals the Fire Marshal's February 26, 2021 denial of a request for a fire sprinkler system exception. The denial letter is enclosed with this Notice of Appeal. Mr. Malik asserts that the City, including the Fire Marshal, have unlawfully discriminated against Mr. Malik while reviewing and making decisions on his permit applications for his Chevron gas station, including his application for a fire sprinkler exception. Mr. Malik believes that other similarly situated buildings have not been required to install fire sprinkler systems. Thus, Mr. Malik requests that the exception be granted. Sincerely, (2, Maxwell C. Burke Enclosure: February 26, 2021 Letter from Fire Marshal Ben Hayman cc: Client (04166958.DOCX; I J nth urke@. carrncro.rs.cono direct: (206) 254-4497 14415 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 19-F-036 1 11. 1L i %I-/ vvv1 v I1V1I-0 L -%J / Lai %VI\ IJV/\ I1 V1 VI\1VU111V1V SYMBOL DESCRIPTION MOUNTING BOX - INSTALLATION NOTES O CONVENTIONAL HEAT DETECTOR RED 4IN OCTAGONAL BOX (BY INSTALLER) CEILING MOUNT WITHIN 25 FT OF SIDE WALL OR CEILING PROJECTION EXTENDING DOWN MORE 12IN. t4 15- Th',- (,r' et Without Comments ® As Noted in Red I] Per The Attached Letter •e plans have been reviewed by The Tukwila Fire rtlon Bureau for conformance with current Cit/ idards. Acceptance is subject to errors and •;slons which do not authorize violations of 1opted ndards and ordinances. The responshiiitry ;Or the '_quacyy of design rests totally with the &-.3Igneer. 'ditions, deletions or revisions to these drawings cite ;s date wi!( vold this acceptance and will require a ubtnitta& of revised drawings for subsequent approva. Tal accept, nce is subject to field test and Inspection by le Tukwila Fire Prevention Bureau. :ate; ),g -I (, By: ) t I TUB r )7 o d .. f `� ,lev Y it i•'� 4 e'rntz No.. and exact a C1, e s for shut- down or restoration zpprovaI. BLOCK DIAGRAM - SYSTEM ;i� n� complete -d, d, Tukwi#a Fire r eo .,t r;(- PrP -test C r ific; I bf2 oresented to prior to -acceptance 1 es{ 1y re /Airm and ii;_:::cr.ti3rl Svst ;ms. Failure of test "till result in a Re -inspection Fee -: lid termination of the testing I-- AREA OF WORK ----� REPLACE EXISTING REPROGRAM ZONE DESCRITION. "HOOD/HEAT DETECTION" L 1 EXISTING TO REMAIN NOT SHOWN ON PLAN IDC— IDC FACP NAC PWR (TYP.) NAC NOTES (CLASS B SYSTEM): O CONVENTIONAL DETECTOR (EOLR AT LAST DEVICE) O CONVENTIONAL MANUAL PULL STATION (EOLR AT LAST DEVICE) OHORNS, STROBES, HORN -STROBES... (EOLR AT LAST DEVICE) ® EXISTING DIALER (TO REMAIN) SUPPLIED EQUIPMENT FOR #FK -0151 QUANTITY MODEL MANUFACTURER DEVICE 1 283B -PL EST CONVENTIONAL HEAT DETECTOR FIRE ALARM SYSTEM OPERATIONS MATRIX SYSTEM OUTPUTS SOUND AND DISPLAY AT FIRE ALARM CONTROL PANEL ACTIVATE HORN STROBE CIRCUITS ALARM SIGNAL TRANSMIT THRU FACP DIALER TROUBLE SIGNAL TRANSMIT THRU FACP DIALER [SUPERVISORY SIGNAL TRANSMIT THRU FACP DIALER ;TEM INPUTS FACP AC POWER LOSS • • FACP BATTERY POWER LOSS • • NAC POWER SUPPLY AC POWER LOSS • • NAC POWER SUPPLY BATTERY POWER LOSS • • FIRE ALARM SYSTEM OPEN CIRCUIT • • FIRE ALARM SYSTEM GROUND FAULT • • FIRE ALARM SYSTEM TROUBLE• • SYSTEM SPRINKLER WATERFLOW SWITCH • • • I'WET WET SYSTEM SPRINKLER TAMPER SWITCH • • HEAT DETECTOR • • • GENERAL SMOKE DETECTOR • • • MANUAL PULL STATION • • • DUCT SMOKE DETECTOR (IF USED) _ • • (NOT ALL INPUTS/OUTPUTS MAY APPLY) SCOPE OF WORK FIRE ALARM SHOP DRAWINGS FOR NEW HEAT DETECTOR, REPROGRAM IDC ZONE DESCRIPTOR EXISTING FIRE ALARM CONTROL PANEL w/ DIALER TO REMAIN. EXISTING NOTIFICATION APPLIANCES (NAC), INITIATION DEVICE CIRCUITS (IDC) AND SPRINKLER MONITORING (IF APPLICABLE) TO REMAIN. PROJECT INFORMATION FIRE ALARM WORK (BOTH DESIGN AND INSTALLATION) FOR EXISTING BUSINESS OCCUPANCY TO COMPLY WITH: NFPA 72, IFC, IBC AND ADA; EDITIONS AS ADOPTED BY THE AUTHORITY HAVING JURISDICTION IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS AND ALL REQUIREMENTS OF THE STATE OF WA, KING COUNTY AND CITY OF KENT P , ID FE3 G'7 2019 TU '{qr ILA FI E 4J/ 2,c 011° PA FEB 07 Z 0 0 0 w>— V) v) J LU L.L J z O CZw U N LU V) LLJ O Q c) O CO 0` � Q O H N Z NLLI NG EC DRAWN BY AC CHECKED BY 1/24/2019 PLAN SUBMITTAL REVISIONS PLOT DATE 1/24/2019 PROJECT #FK -0151 SHEET TITLE COVER SHEET - SYSTEM SCALE N/A SHEET FA -01 OF 1 2019 - IHb ARCH D - SIZE 36X24IN EXISTING FACP w/ DIALER SHADED AREAS NOT IN SCOPE O 1 0 N EXISTING FLOOR PLAN - FIRE ALARM AREA OF WORK EXISTING FIRE ALARM CONTINUED. 1 --- NEW HOOD (BY OTHERS) IDC X REPLACE EXISTING SCALE: 1 /4" = 1'-0" PLAN NOTES: REPROGRAM ZONE DESCRITION AT EXISTING FACP: "HOOD/HEAT DETECTION" OEXISTING FIRE ALARM FIELD DEVICES ARE NOT SHOWN PLAN SYMBOLS SYMBOL DESCRIPTION CONVENTIONAL HEAT DETECTOR Ca 0 FIRE ALARM - WIRE SCHEDULE RS232 (USE 18 AWG PAIR / SHIELDED, TWISTED) Non -Power Limited circuits can never share conduit with Power Limited circuits. 283B -PL HEAT DETECTOR Wiring diagram Listed fire alarm control panel Note: [11 Refer to the wiring diagrams provided with the control panel for proper panel connections and end -of -line resistor value. Heat Detector End -of -Line resistor [11 0 0 F -- L11 (/) J I .LI LL CO15, v x o r O LL C < I— N 2 A N (� TCO OV O N O 0 N LU v) W > 0 O Z co I— U CN I}- N �G EC DRAWN BY AC CHECKED BY 1/24/2019 PLAN SUBMITTAL REVISIONS PLOT DATE 1/24/2019 PROJECT #FK -0151 SHEET TITLE AREA OF WORK FIRE ALARM SCALE 1 /4" = V-0" SHEET FA -02 OF 2 ARCH D - SIZE 36X241N ABCDEFHPX 12 AWG PAIR • 14 AWG PAIR • • • _ 16 AWG PAIR • • 18 AWG PAIR • • • FPLR OR FPLP (AS REQUIRED) • • • • • • • • • SHIELDED • TWISTED • RATED FOR UNDERGROUND AND WET CONDITIONS (AS REQUIRED) • • • • • • • • • SIGNAL LINE CIRCUIT (SLC) • CONVENTIONAL INITIATING DEVICE CIRCUIT (IDC) • ZONE INPUT • RELAY OUTPUT • NOTIFICATION APPLIANCE CIRCUIT (NAC) • REMOTE ANNUNCIATOR 24VDC PWR • REMOTE ANNUNCIATOR RS485 DATA • AUDIO RISER • SPEAKER CIRCUIT • DOOR HOLDER CIRCUIT • AUX 24VDC PWR • RS232 (USE 18 AWG PAIR / SHIELDED, TWISTED) Non -Power Limited circuits can never share conduit with Power Limited circuits. 283B -PL HEAT DETECTOR Wiring diagram Listed fire alarm control panel Note: [11 Refer to the wiring diagrams provided with the control panel for proper panel connections and end -of -line resistor value. Heat Detector End -of -Line resistor [11 0 0 F -- L11 (/) J I .LI LL CO15, v x o r O LL C < I— N 2 A N (� TCO OV O N O 0 N LU v) W > 0 O Z co I— U CN I}- N �G EC DRAWN BY AC CHECKED BY 1/24/2019 PLAN SUBMITTAL REVISIONS PLOT DATE 1/24/2019 PROJECT #FK -0151 SHEET TITLE AREA OF WORK FIRE ALARM SCALE 1 /4" = V-0" SHEET FA -02 OF 2 ARCH D - SIZE 36X241N