Loading...
HomeMy WebLinkAboutPP - 14625 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS14625 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 14-S-174 r h 44itt,"44 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 004000-0865 Site Address: 14625 Tukwila International Blvd Suite Number: Floor: Tenant Name: AutoZone Store 4181 New Tenant? ❑ - Yes ❑ - No Property Owner's Name: AutoZone Development - Mitch Bramlitt Mailing Address: 123 South Front Street Memphis TN 38103 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Mitch Bramlitt Day Telephone: 901-495-8714 Company Name: AutoZone Development Mailing Address: 123 South Front Memphis TN 38103 City State Zip E-mail Address: mitch.bramlitt@autozone.com Fax Number: 901-495-8991 Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 2 2 500 (est ) Scope of Work (please provide detailed information): Fire Sprinkler system for a New AutoZone Retail Store. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ER OR AUTHtOr ED AGENT: Signature: Print Name: Mitch Bramlitt Plan Permit App.doc Date: - k7-(4- Day Telephone: 901-495-8714 1/2/13 TFD FP Forrn 8 S 1 • FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: AutoZone 14625 Tukwila Intl BI Permit No.: 14-S-174 Date: August 13, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/z inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-02, section 9.6.2.6.2 (e). • Ceilings used for flex drop attachments shall comply with ASTM C 635 and ASTM C 636 per section 9.2.1.3.3.2. • Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a suspended ceiling, a hanger(s) attached to the structure shall be required to ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3). • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Maintain a 4 ft. clear space around the sprinkler riser for emergency access. • When the sprinkler riser is located inside a room, the door to the room shall have a sign with one -inch letters which reads "SPRINKLER RISER". • The height of the fire department connection (FDC) shall be 36 to 48 inches. • The FDC shall have a downward angle bend of 30 degrees with a 5 —inch Storz connection and a Knox locking Storz cap. • When subject to vehicular damage, protective guard posts or curbs are required around sprinkler valves and hydrants. Posts and curbs are to be painted yellow. • All exterior components of sprinkler systems shall be painted red. • Post indicator valves (PIV's) shall have the building address served by the PIV stenciled vertically in 3 -inch high white numbers on a "safety red" background, facing the direction of vehicular access. • All control, drain, and test connection valves shall be provided with permanently marked weather-proof metal or rigid plastic identification signs. • All interior control valves shall be readily accessible, labeled, and located not more than 6 ft. above the floor. • Modifications involving 20 or more sprinkler heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a Toss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. f Hunter Design & Consulting, Inc. DESIGNER: GARY HUNTER 3S 634 Behr's Circle Drive East Warrenville, Illinois 60555 HYDRAULIC CALCULATIONS FOR AUTOZONE 14625 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA FILE NUMBER: 14095 DATE: 06-06-2014 -DESIGN DATA - OCCUPANCY CLASSIFICATION: MERCANTILE (2002 NFPA 13 ED.) WET SYSTEM (Ord. Hazard Grp. II) AREA OF APPLICATION: .20/1500 sq. ft. COVERAGE PER SPRINKLER: 120 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 17 sprinklers TOTAL SPRINKLER WATER FLOW SPRINKLERS: 444.5 gpm SPRINKLER WATER FLOW REQUIRED w/ hose: 694.5 gpm FLOW AND PRESSURE (@ BOR): 44.5 gpm @ 62.5 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: N/A DESIGN/LAYOUT BY: GM (NICET Cert. #091352) AUTHORITY HAVING JURISDICTION: Tukwila Fire Department CONTRACTOR CERTIFICATION NUMBER: N/A CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. TUCKER, GA 30084 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 90.0 67.0 2650.0 88.1 694.5 69.8 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 694.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 444.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 13.7 K= 5.60 18.4 24.0 2 13.7 K= 5.60 18.5 24.1 3 13.7 K= 5.60 19.1 24.5 4 13.7 K= 5.60 20.1 25.1 5 13.7 K= 5.60 22.3 26.4 6 13.7 K= 5.60 25.6 28.3 7 13.7 - - - - 30.5 8 13.0 38.9 9 13.5 38.9 10 14.2 - - - - 30.5 11 14.2 K= 5.60 18.4 24.0 12 14.2 K= 5.60 18.5 24.1 13 14.2 K= 5.60 19.1 24.5 14 14.2 K= 5.60 20.1 25.1 15 14.2 K= 5.60 22.3 26.4 16 14.2 K= 5.60 25.6 28.3 17 14.0 - - - - 39.6 18 14.7 - - - - 32.4 - - - 19 14.7 K= 5.60 23.2 27.0 20 14.7 K= 5.60 23.4 27.1 21 14.7 K= 5.60 24.0 27.4 22 14.7 K= 5.60 25.6 28.3 23 14.7 K= 5.60 28.2 29.8 24 15.8 - - - - 45.3 TOR 15.8 54.1 BOR 1.0 62.5 UG -3.0 64.3 BF1 3.0 62.7 BF2 3.0 - - - - 66.7 - - - SRC -3.0 SOURCE 69.8 444.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -24.0 1.728 PL 10.00 PF 0.2 1 13.7 5.6 18.4 24.0 3.3 120 FTG ---- PE 0.0 2 13.7 5.6 18.5 24.1 0.016 TL 10.00 PV Pipe: 2 -48.1 1.728 PL 10.00 PF 0.6 2 13.7 5.6 18.5 24.1 6.6 120 FTG ---- PE 0.0 3 13.7 5.6 19.1 24.5 0.058 TL 10.00 PV Pipe: 3 -72.6 1.728 PL 8.00 PF 1.0 3 13.7 5.6 19.1 24.5 9.9 120 FTG ---- PE 0.0 4 13.7 5.6 20.1 25.1 0.124 TL 8.00 PV Pipe: 4 -97.7 1.728 PL 10.00 PF 2.2 4 13.7 5.6 20.1 25.1 13.4 120 FTG ---- PE 0.0 5 13.7 5.6 22.3 26.4 0.215 TL 10.00 PV Pipe: 5 -124.1 1.728 PL 10.00 PF 3.4 5 13.7 5.6 22.3 26.4 17.0 120 FTG ---- PE 0.0 6 13.7 5.6 25.6 28.3 0.335 TL 10.00 PV Pipe: 6 -152.5 1.728 PL 9.92 PF 4.9 6 13.7 5.6 25.6 28.3 20.9 120 FTG ---- PE 0.0 7 13.7 0.0 30.5 0.0 0.490 TL 9.92 PV Pipe: 7 -152.5 1.728 PL 0.67 PF 8.2 7 13.7 0.0 30.5 0.0 20.9 120 FTG 2T PE 0.3 8 13.0 0.0 38.9 0.0 0.490 TL 16.67 PV Pipe: 8 -152.5 3.314 PL 10.00 PF 0.2 8 13.0 0.0 38.9 0.0 5.7 120 FTG ---- PE -0.2 9 13.5 0.0 38.9 0.0 0.021 TL 10.00 PV Pipe: 9 152.4 1.728 PL 0.67 PF 8.2 9 13.5 0.0 38.9 0.0 20.9 120 FTG 2T PE -0.3 10 14.2 0.0 30.5 0.0 0.490 TL 16.67 PV Pipe: 10 -24.0 1.728 PL 10.00 PF 0.2 11 14.2 5.6 18.4 24.0 3.3 120 FTG ---- PE 0.0 12 14.2 5.6 18.5 24.1 0.016 TL 10.00 PV Pipe: 11 -48.1 1.728 PL 10.00 PF 0.6 12 14.2 5.6 18.5 24.1 6.6 120 FTG ---- PE 0.0 13 14.2 5.6 19.1 24.5 0.058 TL 10.00 PV Pipe: 12 -72.6 1.728 PL 8.00 PF 1.0 13 14.2 5.6 19.1 24.5 9.9 120 FTG ---- PE 0.0 14 14.2 5.6 20.1 25.1 0.124 TL 8.00 PV b SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -97.7 1.728 PL 10.00 PF 2.2 14 14.2 5.6 20.1 25.1 13.4 120 FTG ---- PE 0.0 15 14.2 5.6 22.3 26.4 0.215 TL 10.00 PV Pipe: 14 -124.1 1.728 PL 10.00 PF 3.4 15 14.2 5.6 22.3 26.4 17.0 120 FTG ---- PE 0.0 16 14.2 5.6 25.6 28.3 0.335 TL 10.00 PV Pipe: 15 -152.4 1.728 PL 9.92 PF 4.9 16 14.2 5.6 25.6 28.3 20.9 120 FTG ---- PE 0.0 10 14.2 0.0 30.5 0.0 0.490 TL 9.92 PV Pipe: 16 -304.9 3.314 PL 12.00 PF 0.9 9 13.5 0.0 38.9 0.0 11.3 120 FTG ---- PE -0.2 17 14.0 0.0 39.6 0.0 0.074 TL 12.00 PV Pipe: 17 139.6 1.728 PL 0.67 PF 6.9 17 14.0 0.0 39.6 0.0 19.1 120 FTG 2T PE -0.3 18 14.7 0.0 32.4 0.0 0.417 TL 16.67 PV Pipe: 18 -27.0 1.728 PL 10.00 PF 0.2 19 14.7 5.6 23.2 27.0 3.7 120 FTG ---- FE 0.0 20 14.7 5.6 23.4 27.1 0.020 TL 10.00 PV Pipe: 19 -54.1 1.728 PL 8.00 PF 0.6 20 14.7 5.6 23.4 27.1 7.4 120 FTG ---- PE 0.0 21 14.7 5.6 24.0 27.4 0.072 TL 8.00 PV Pipe: 20 -81.6 1.728 PL 10.00 PF 1.5 21 14.7 5.6 24.0 27.4 11.2 120 FTG ---- PE 0.0 22 14.7 5.6 25.6 28.3 0.154 TL 10.00 PV Pipe: 21 -109.9 1.728 PL 10.00 PF 2.7 22 14.7 5.6 25.6 28.3 15.0 120 FTG ---- PE 0.0 23 14.7 5.6 28.2 29.8 0.268 TL 10.00 PV Pipe: 22 -139.6 1.728 PL 9.92 PF 4.1 23 14.7 5.6 28.2 29.8 19.1 120 FTG ---- PE 0.0 18 14.7 0.0 32.4 0.0 0.417 TL 9.92 PV Pipe: 23 -444.5 3.314 PL 36.50 PF 6.5 17 14.0 0.0 39.6 0.0 16.5 120 FTG E PE -0.8 24 15.8 0.0 45.3 0.0 0.149 TL 43.50 PV Pipe: 24 -444.5 3.314 PL 51.92 PF 8.8 24 15.8 0.0 45.3 0.0 16.5 120 FTG E PE 0.0 TOR 15.8 0.0 54.1 0.0 0.149 TL 58.92 PV Pipe: 25 -444.5 4.310 PL 14.75 PF 2.0 TOR 15.8 0.0 54.1 0.0 9.8 120 FTG CB PE 6.4 BOR 1.0 0.0 62.5 0.0 0.041 TL 48.75 PV f . 4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM). FL/FT (PSI) Pipe: 26 -444.5 6.270 PL 4.00 PF 0.1 BOR 1.0 0.0 62.5 0.0 4.6 140 FTG L PE 1.7 UG -3.0 0.0 64.3 0.0 0.005 TL 18.07 PV Pipe: 27 -444.5 6.270 PL 145.00 PF 1.0 UG -3.0 0.0 64.3 0.0 4.6 140 FTG 3LG PE -2.6 BF1 3.0 0.0 62.7 0.0 0.005 TL 191.91 PV Pipe: 28 FIXED PRESSURE LOSS DEVICE BF2 3.0 0.0 66.7 0.0 4.0 psi, 444.5 gpm BF1 3.0 0.0 62.7 0.0 Pipe: 29 -444.5 6.270 PL 23.00 PF 0.5 BF2 3.0 0.0 66.7 0.0 4.6 140 FTG T2LG PE 2.6 SRC -3.0 SRCE 69.8 (N/A) 0.005 TL 102.75 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.4 computer program under license no. 50091140 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.052 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 20.9 ft/sec at pipe 7. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node SRC under full flow conditions is 87.71 psi compared to the minimum required pressure of 20.00 psi. (6) PIPE FITTINGS TABLE Pipe Table Name: ROADRUNNER.PIP 1 . c SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone PAGE: * Diameter (in) 6.270 PAGE: D Diameter (in) 1.728 3.314 4.310 MATERIAL: S40 HWC: 120 Equivalent Fitting Lengths E T L C B Ell Tee LngEll ChkV1v BfyVly 16.46 35.27 10.58 37.62 11.76 in Feet G A D N GatVly AlmChk DPV1v NPTee '3.53 32.92 32.92 35.27 MATERIAL: DYNAFL HWC: 120 Equivalent Fitting Lengths in Feet E T L C B G A D Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v 4.00 8.00 2.00 9.00 6.00 1.00 10.00 13.00 7.00 15.00 5.00 16.00 10.00 1.00 13.00 12.00 10.00 20.00 6.00 22.00 12.00 2.00 20.00 12.00 4 4 DATE: 6/6/2014 JOB TITLE: AutoZone WATER SUPPLY ANALYSIS SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 C:\HASS DATA\14095.SDF W W Q. 0, N N I tT tT 0 0 C) U U : u ,n a) 10 = 0 • 1-1 • ?i b W er 0 C ri C W an N 01 Q. b W to W ID 0. 0 • N a) 0 W : 0, au 34 au VIA 1 O. ■ W -.i -.I W a .%I r -.H4 N 00 ?, • -.I 0 0 CO ci p1 tT ao W 0% 1 1/40 00 10 0 • 0 0 O O O O 0 0 0 0 .--1 CO l0 d' N O O 0 O C M 0 0 O 0 Olikr 0 0 "11i ri SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 6/6/2014 C:\HASS DATA\14095.SDF JOB TITLE: AutoZone WATER SUPPLY CURVE 96+ *\\ 88+ 0\\ \\\ 80+ \\\ 1 \\\ 72+ \\ \\\ \\\ 1 X \\ * <-67 0 psi @ 2650 gpm Flow Test Point P 64+ R 1 E 1 S 1 S 56+ U I R 1 E 1 48+ ( I P I S 1 I 40+ ) I 1 32+ 24+ 16+ LEGEND 1 8+ X = Required Water Supply 69.82 psi @ 694.5 gpm 0 = Available Water Supply 88.07 psi @ 694.5 gpm11 IV 11 11 11 11 11 11 0++-+---+----+ + + + + + + 8001200 1600 2000 2400 2800 3200 3600 4000 FLOW (GPM) COPYRIGHT 2007 { L_ til fII II 1l AutoZone Jli it it � t -i" / / 94-0 <BF> <6F2> /EI f1 / / I /J / / / / / / I ;/ �� ,J/ f Pte, / / I / / /1 / 1 1 l r // / I /1 /// /1` / / / / / / 7 / /;/ /1' i FOR RI- Fl - FIR S -)RI\ 1" = 20' —0" O\LY KLFH SITS LA\ V / p Without Comments ` As Noted in Red Per The Attached Letter plans have been reviewed by The Tukwila Fire ntion Bureau for conformance with current City lards. Acceptance is subject to errors and d aif ds and ordinances. The respons bllityforr the ivacy of design rests totally with the designer. ;tions, deletions or revisions to these idjgsre after date will void this acceptance and ubmittal of revised drawings for subsequent approval. nal acceptance Is subject to fleld test and inspection by ne Tukwila Fire Prevention Bureau. Date: �- - I By: I FIRE PROTECTION SUPPLY TO FIRE RISER. SEE RISER DETAIL FOR CONT. PIPE SLEEVE THRU SLAB EFER TO DETAIL A )\./NALL FINISH /GRADE CL 50 D.I.P./.4\•//` CORROSION RESISTANT ANCHOR RODS (4) SIZE PER N.F.P.A. 24 RETAINING GLAND (3) 1- z w wa n. D t- Cz CONCRETE >- FOOTING m CONCRETE THRUST BLOCK PER STD. MAG DETAIL 380 CL. 50 D.I.P/ FIRE PROTECTION' SUPPLY. SEE SITE PLAN FOR CONT. 8U � 0 w m ,n X FIRE PROTECTION SUPPLY. SEE SITE PLAN FOR CONT. �____--FIRE RISER ROOM EXTERIOR WALL 18n -FIRETORISERPROTECTIONSEERISERSUPPLY . DETAIL FOR CONT. DETAIL 'A' UNDERGROUND STUB UP DETAIL FLOW TEST SUMMARY STATIC PSI RESIDUAL PSI PITOT PSI 100.0 77.0 20.0 ORIFICE DIAMETER N /A COEFFICIENT OF DISCHARGE N /A GPM 2650 DATE: 5-5-2014 WATER MODEL LOCATION: MARK PARSONS CONDUCTED BY: KING COUNTY WATER FLOW TEST UTILIZED STATIC PSI RESIDUAL PSI PITOT PSI 20.0 ORIFICE DIAMETER 90.0 67.0 N /A COEFFICIENT OF DISCHARGE N /A GPM 2650 KEYNOTES: 0 4" FIRE RISER (REFER TO FP3 FOR DETAIL) 10" ELECTRIC BELL (WIRED BY ELECT. CONTR.) 4" x 2W' x 21" FIRE DEPT. CONN (NST) w/ 4" CHECK VALVE & 1" AUTO. DRIP VALVE THRUST BLOCKS PER NFPA #24. TYP. TEE & VALVE EXISTING WATER MAIN 36" MINIMUM BURY (DEPTH PER NFPA #13.) FIRE HYDRANT POST INDICATOR VALVE w/ TAMPER SWITCH BACKFLOW ASSEMBLY w/ TAMPER SWITCH THE A.H.J. SHALL BE NOTIFIED A MINIMUM OF 48 - HOURS PRIOR TO THE FOLLOWING TESTS: A. A TWO-HOUR, TWO HUNDRED (200) PSI HYDROSTATIC TEST B. A TEST AT THE INSPECTORS TEST PIPE TO DETERMINE ALL WATER FLOW DEVICES AND ALARM CIRCUITS ARE WORKING PROPERLY. C. A MAIN DRAIN TEST WILL BE CONDUCTED, BOTH, BEFORE AND AFTER THE SPECIFIED WORK IS COMPLETE. _1 JKWILA FIRE DEPARTMENT Please call 206-575-4407 and the thI Fire it No. and exact address for shut- down hutdown or restoration approval. PAID Jul. 23 2014 T UKWIL�A/ FIRE &- 2/f / NATHAN J. PIES, P.E. 4159 EAST VEST AVE. Gilbert, Arizona 85295 509-833-0367 T NATHAN.PIES@GMAIL.COM REVISIONS W rz > i w c z Q -t- L() CD .- w c N w c N) w c N t'r) AutoZone Store No. 4181 14625 TUKWILA INTERNATIONAL BLVD TUKWILA WA 98168 0 LIUF— E SPRINKLER SI C Vk� z G�coIFIED LF GSA CERT �\ 091352 o GA'' MC11 L S%1I N. 40 .OS a, ', GF do 3S634 Behr's Circle Drive East Warrenville, Illinois, 60555 LI N T E R (877) 435-8108 Phone (630) 791-9792 Fox: 1505 West University Drive ESIGN T 101 Tempe, AZ 85281 goryOhunterdesign 1. com FIRE PROTECTION ENGINEERING AND O N S U L T I N G DESIGN SERVICES V$;' 41 -- of ttfl <, .r ,W 4. EXFtRES /: /8 ' 015 06/06/14 7N2 -R /1/1 f1\/111/\1 IT !1/\/17 UPRIGHT SPRINKLER STEEL DECKING STEEL BAR JOIST 1 - Li_- T. 1 1I1 111. 1 111 111 1 V 1 IIP BRANCH UNE CROSS MAIN w/ SLOPE OF DECK CROSS SECTION A 1/8" = i'—o" FIRE SPRINKLER SCHEDULE SYM CNT POSITION FINISH TEMP K NPT SIN MFG. MODEL# 0 78 UPR BRASS 155 5.60 1/2" TY3131 Tyco TY -FRB ® 3 PEND CHROME 155 5.60 1/2" TY3231 Tyco TY -FRB CALCULATION DESIGN INFORMATION AREA AREA ONE OCCUPANCY MERCANTILE (MISC. STORAGE) HAZARD ORD. HAZ. GRP. II DENSITY .20 GPM /SQ. FT. AREA OF OPERATION 1500 SQ. FT. AREA PER HEAD 120 SQ. FT. HOSE WATER ALLOWANCE INSIDE o OUTSIDE - 250 SYSTEM DEMAND PSI 69.8 GPM 444.5 PSI AVAILABLE 88.1 GPM AVAILABLE 444.5 3S634 Behr's Circle Drive East Warrenville, Illinois, 60555 ]E-TUNTER (877) 435-8108 Phone (630) 791-9792 Fox: 1505 West University Drive 1;7: D ESIGN Suite 1 Tempet OAZ 85281 gory®hunterdesign1.com FIRE PROTECTION ENGINEERING C AND O N S U L T I N G DESIGN SERVICES I CAUTION THIS BUILDING IS PROTECTED BY A HYDRAULICALLY DESIGNED AUTOMATIC SPRINKLER SYSTEM. DO NOT ALTER OR ADD TO THE SYSTEM BEFORE CONSULTING INSTALLATION DRAWINGS. SYSTEM NUMBER LOCATION NUMBER OF SPRINKLERS BASIS OF DESIGN 1. DENSITY 2. DESIGNED AREA OF DISCHARGE . SYSTEM DEMAND 1. GPM DISCHARGE 2. RESIDUAL PRESSURE AT THE BASE OF THE RISER INSTALLED BY: AREA ONE ADDRESS] 17 .20 GPM/SQ.FT. 1500 SQ.FT. 444.5 GPM 62.5 PSI SYSTEM DESIGN CRITERIA OCCUPANCY: MERCANTILE (12'-0") MAXIMUM STORAGE ONLY N.F.P.A. 13 2010 EDITION COMMERCIAL SYSTEM BASED ON A MISC. STORAGE OCCUPANCY. ORD. HAZARD GROUP II SPRINKLER SPACING @ 120 SQ. FT. MAX. NFPA 14.2.3 2010 EDITION HYDRAULIC DENSITY .20 GPM/SQ. FT. w/ 1500 SQ. FT. DESIGN AREA. 250 GPM HOSE. STRUCTURE TO BE NON/COMBUSTIBLE OPEN WEB STEEL JOIST CONSTRUCTION. JOIST SPACING 7'-0" 0.C. TYPICAL. ALL NEW DROPS AND ARMOVERS SHALL BE DYNA THREAD. ALL NEW BRANCH LINES, CROSS MAINS, BULK MAIN AND RISER PIPING SHALL BE DYNA FLOW. USING 155 DEGREE SPRKS. TOR) 4" FIRE RISER REFER TO FP3 DETAIL #}1 <BOR) 10" ELECTRIC BELL IMRED BY ELECT. CONTRACTOR W4vtll f• -•(k '5D "&°J1 f22Z ... 12 s-- '.-7////7/ZW'?77277Z 7777 a /777/7:7-..7;177= 277ZZ 77772 i72Z I 112 . t .. — BRANCHTNES APt4ROX 12!--;1310. w/;SLOPE SHALL' OF ROOF E _LOCATED CR iSsMAI4- DECK REMOTE./'AREA] x7 .20/1500 8Q., FT T /7r JOISTS 0. RANCH LINES SHILL BE LOCATED PPROX. 12" B.B.D.: CROSS MAIN / SLOPE OF ROOF DECK 1121 4-r 777 77777777 77-7 t_777 7777-777A i/// 71777774 INSP. TEST VALVE w/ 1/2" :ORF. 5'-6" A.F.F. REFER TO DETAIL ON FP3 17'-3120TI 4" x 21/4" x 2W FIRE DEPT. CONN. (PHT) w/ 4" CHECK VALVE. FIRE SPRINKLER PIPING PLAN 1/8" = 1'--0" (2-7z77/t /7/ y -.7./7/7///, = NATHAN J. PIES, P.E. 4159 EAST VEST AVE. Gilbert, Arizona 85295 509-833-0367 T NATHAN.PIEShc@GMAIL.COM REVISIONS 1 REV1 4 REV4 2 REV2 5 REV5 3 REV3 6 REV6 ER PIPING PLAN - i— z d — T N Q y z L C/) j cU D < c 1 IPI to 5 a_ (f) W 3S634 Behr's Circle Drive East Warrenville, Illinois, 60555 ]E-TUNTER (877) 435-8108 Phone (630) 791-9792 Fox: 1505 West University Drive 1;7: D ESIGN Suite 1 Tempet OAZ 85281 gory®hunterdesign1.com FIRE PROTECTION ENGINEERING C AND O N S U L T I N G DESIGN SERVICES COPYRIGHT 2007 GENERAL SYSTEM FIRE PROTECTION NOTES: 1. Fire Protection Contractor is responsible for: field fit of sprinkler piping, accuracy of prefabricated pipe, location of sprinklers (per NFPA and inspections), piping elevations dimensioning and general workmanship of sprinkler system. 2. Verify field conditions prior to installation and make field adjustments, as necessary, for field acceptance by author- ities having jurisdiction. 3. Fire Protection Contractor shall coordinate the installation of piping and sprinklers with structural members, ductwork, mechanical equipment, ceiling, lights, etc. 4. Field verify spacing of sprinklers and deflector distances with respect to structural components, lights, etc., and make field adjustments, as necessary, to comply with NFPA-13 requirements. Provide additional sprinklers, or respace sprinklers to avoid obstructions to discharge patterns. Provide a minimum of 6 -feet between any two sprinklers to avoid cold soldering. 5. A sufficient safety factor has been implemented into this design. PIONEER DESIGN & ENGINEERING is not responsible for changes in the city water supply that may adversely affect this A.S. System in the future. 6. Pipe hangers, and sway bracing shall be spaced as indicated on these drawings and/or per NFPA-13. 7. Fire Protection Contractor shall provide sleeves at all piping penetrations through masonry walls and floors. Pack with approved sealants per NFPA and local authorities. 8. Fire Protection Contractor shall provide and install a design placard on each riser indicating remote area size and location, sprinkler design density (gpm), and water requirements at base of riser. Also, include installing Contractors name and date of installation. Coordinate placard information with insurance carrier where required. 9. Fire Sprinkler System shall be monitored by Owner's central station supervision equipment. 10. Fire Protection Contractor shall verify all dimensions, riser nipple lengths, pipe elevations, etc., and make all necessary adjustments. 11. All control valves (including main drain) shall be chained and locked for security. FROM MOST REMOTE BRANCH LINE 1" GLOBE VALVE yr - NOTE: PROVIDE STANDARD METAL SIGNS IN ACCORDANCE WITH N.F.P.A. 13. PER NFPA 13, ALL PIPING AND FITTINGS EXPOSED THE WEATHER, CORROSION TYPES OF PIPE, FITTINGS AND HANGERS OR PROTECTIVE CORROSION COATINGS SHALL BE USED. NFPA 13, 8.16.4.2.1 AND 8.16.4.2.3 PROVIDE CHROME PLATED TWO PIECE ESCUTCHEONS AT ALL PENETRATIONS OF MASONRY WALLS. GALVANIZED PIPE w/ 45 DEGREE ELBOW WITH 1/2" ORIFICE INSPECTORS TEST DETAIL NTS OL �O HYDRAULIC - SYSTEM This Building is Protected by a Hydraulically Designed Automatic Sprinkler System. Location No. of Sprinklers Basis of Design DENSITY DESIGNED AREA OF DISCHARGE GPM/Sq. Ff. Sq. FT. System Demand GPM DISCHARGE RESIDUAL PRESSURE AT THE BASE OF RISER GPM PSI (O SAMPLE HYDRAULIC DESIGN PLACARD NTS NOTE: REFER TO FIRE PROTECTION SPECIFICATIONS. CONTRACTOR TO SUPPLY ONE SET OF MYLAR FIRE PROTECTION DOCUMENTS MINIMUM. AS BUILT CABINET NTS ROOF DECK TOP BEAM CLAMP i i JOIST OR JOIST GIRDER STEEL JOIST 0 2 UPRIGHT SPRK. HANGER RING DEFLECTOR DISTANCE DETAIL NTS STEEL JOIST ALL THREAD ROD HANGER RING FOR PIPE 4" & SMALLER 1 --3/8" TOP BEAM CLAMP 1 -- LENGTH OF 3/8" A.T.R. (O'-10") 1 -- PIPE HANGER RING TOP BEAM --CLAN P HANGER DETAIL NTS Project Address: AUTOZONE Calculations based on 2010 NFPA Pamphlet }}13 34' 0" (10.36 m) Tolco Component Fig. Number Least Rad. of Gyration 0A2" (11 mm) LVR Value 200 Max Horizontal Load 1310 lbs (594 kg) Fig.980 Universal Swivel 'Calculation Based an CONCENTRIC Loading `Please Nate: These ccIculatiarrs are for Tc`co components on`y. Use of any other components voids these calctJ ons and the listing of the assembly. Assembly Detail TOLCO FIG. 98 UNIVERSAL SWAY BRACE ATTACHMENT STEEL PIPE LATERAL BRACE Fastener Orientation NFPA Type B ication on Plans 31 Size and 'type of Pipe Total Length Total Calculated Load 3' Sch_7 Steel Pipe (76.2 rum) 34ft (10.4 m) 1691bs (77 kg) 1.5" Sch.7 Steell Pipe (38.1 mm) 330ft (100.6 m) 655 Ibs (297 kg) Maximum Spacing 80' 4" (24.8 mn) Percentage added for Fittings and Sprinklers 15% 124 lbs (56.25 kg) Total Adjusted Load of all pipe within Zone of Influence 947 Ibs (430 kg) KEY QTY DESCRIPTION 0 SEE STUB UP DETAIL THIS SHEET FOR CONT. o SPLASH BLOCK (BY G.C.) O TYP. SLEEVE THROUGH FLOOR/WALL 0 HYDRAULIC CALCULATION PLATE O 1* 10" ELECTRIC BELL FLANGED CONNECTION TYP. GROOVED ELBOW 1* FLOW SWITCH 0 TYP. FLEXIBLE COUPLING 0 4 -WAY BRACING SECURED TO STRUCTURE 11 2" MAIN DRAIN ANGLE VALVE w/ PRESSURE RELIEF VALVE 12 2" DRAIN. TERM 6" ABOVE FIN. GRADE 8 300 PSI PRESSURE GUAGE SPARE SPRINKLER BOX (2 RECESS 155 DEGREE/4 UPRIGHT) REFER TO FP2.0 FOR MANUFACTURER. PROVIDE WRENCH FOR EACH TYPE AND OPERATIONS AND MAINTENANCE MANUAL. CURRENT EDITION *WIRED BY ELECTRICAL/ALARM CONTRACTOR PROVIDE PRESSURE RELIEF VALVE FOR GRIDDED SYSTEMS. NFPA 13 2007 EDITION. NOTES 1. FIRE SPRINKLER SYSTEM TO BE MONITORED BY A U.L. OR F.M. LISTED CENTRAL STATION FOR FLOW, TAMPER AND TROUBLE. 2. INSTALL DESIGN PLACARD ON EACH RISER PER NFPA-13. 3. ALL VALVES SHALL BE A MAX. OF 7'-O" A.F.F. 4. WHERE REQUIRED BY A.H.J., PROVIDE MEANS DOWNSTREAM OF ALL BACKFLOW PREVENTION VALVES TO ACCOMODATE FLOW TESTS AT SYSTEM DEMAND. FINISHED GRADE CONCRETE FOOTING TO ROOF LEVEL (� SPRINKLER PIPING HW 101 FINISHED FLOOR FIRE SPRINKLER RISER DETAIL NTS n n TOLCO FIG. 909 (2) TOLCO FIG. 1000 "FAST CLAMP"1/ (2) FIG. 1001 FOR THINWALL 4 -WAY AT RISER Size and Type sof Pipe Toi-Brace Seismic Calculations Project Address: AUTOZONE 4" Sch.7 Steel Pipe (101.6 mm) R B -Line 14625TU KWILA INTERNATIONAL BLS TUKWILA, WA I TO Q Job * Calculations based on 2010 NFPA Pamphlet #13 Brace Inform ation Tolco Brace Components Maximum Spacing 80' 4" (24.8 mn) Tolco Component Fig. Number Adjusted Load FigAL Clamp 1425 Ibs (646 kg) Fig 909 Nc-Thread Swivel 1425 Ibs (646 kg) `Calculation Based an CONCENTRIC Loading *Please Note: These calculations are forTaco components on=y_ Use of any other components vcds these calculations and the listing at the assembly. Maximum Brace Length 7' 0" (2.13 m) Bracing Material 1" Sch.40 Angle from Vertical 45" Min. Least Rad. of Gyration 0A2" (Um Assembly TOLCO P40•Ttif#EAI3 SWIVEL aRACE ATTACHMENT' STEEL LATERAL PiTOL OA FIG. o CLAMP SWAY 6RACI G % ( Detail FIG. 909 SWAY-------.... PIPE BRACE s,1 1 LIR Value 200 Max Horizontal Load 1310 Ibs (594 kg) Force Factor (Cp) 0.6935 Fastener Inf+rmaton Fastener Orientation NFPA Type H Type Bolt Diameter 1/2n. (12 Winn) Length N/A a. CO W Ct Brace Identification on Plans 31 Maximum Load 1830 lbs (830 kg) Orientation of Brace Longitudinal Braced Pipe: 4" Sch.7 Steel Pipe Load Information Size and Type sof Pipe Total Length Total Calculated Load 4" Sch.7 Steel Pipe (101.6 mm) 30ft (24.4 m) 626 lbs (284 kg) -1- Percentage added for Fittings and Sprinklers 15% 94 lbs (42.64 kg) Total Adjusted Load of all pipe within Zone of lntiuence 720 Ibs (327 kg) {Tar -grace Version 7} TOP BEAM CLAMP w/ RESTRAINING STRAP TOP BEAM CLAMP w/ RESTRAINING STRAP > w o% > w o✓ CIO w TOLCO SWIVEL 3/8" ALL THREAD ROD TIGHT TO PIPE OR USE SURGE RESTRAINER. END OF LINE RESTRAINT O BE WITHIN 6" OF ND IN LINE HANGER -1- HANGER ROD '&P „5 CD CI) W > > STEEL PIPE SEISMIC RESTRAINT DETAIL Design Maps Summary Report MUMS Design Maps Summary Report User -Specified Input Building Code Reference Document 2012 International Building Code uni._e; €-;aza:-•:I c._.. : •.a!ablein 2608) Site Coordinates 47.47179°N, 122.28512°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/1I/III Page 1 of 1 East Ror Highland USGS-Provided Output Ss= 1.487g S, = 0.557 g S„s = 1.487 g S„I = 0.835 g Sos = 0.992 g 50, = 0.557 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1-65 1.50 1.15 1.20 1,05 0.90 0.75 0.60 0.45 0.30 0.15 0.00 0.00 0.20 0.10 O' R 1.10 1.00 0.50 0.50 0.70 0.00 0.50 0.40 0.30 0.20 0.10 Design Response Spectrum 0.00 0.40 0.80 1.00 1.20 1.40 1.00 1.50 2.00 0.00 0.20 0.40 0.00 0.00 1.00 1.20 1.40 1.60 180 2.00 Period, T (sec) Period, T (sec) nat�c=�ch '_hi, information is a product of the U.S. tee" _.7cai axF,res_F. rs ,;-:... _, �-: at:.uacv of the data contained therein. This rcc4 is nota suLisritLir.e €ter o .:hr ,_a; <.-matto^ kno.4?edci-. httpl/ehp4-earthquake.cr.usgs.gov/designmapsius/summary.php?template-minimal&latitud... 6/6/2014 0 0 J Q (1)0 w d z z > w f > w o% > w o✓ CIO w -1- L.0 cO CD CI) W > > AutoZone Store No. 4181 14625 TUKWILA INTERNATIONAL BLVD. TUKWILA WA 98168 0 z \ () Ct W J/ Z 11 a. CO W Ct `(1 F I E0 '\ �C,CERT GFS �\ 091352� �� o GA -4 MC AL, L G tp /A`U..3r-., es bit\ 3S634 Behr's Circle Drive East Warrenville, Illinois, 60555 U N T E R (877) 435-8108 Phone (630) 791-9792 Fax: 1505 West University Drive E S I G N Suite 101 Tempe, AZ 85281 gary®hunterdesign 1.com FIRE PROTECTION ENGINEERING AND ONS U L T I N G DESIGN SERVICES Z44.4' A �(I Com Ul i.z' toaaa EXPIRES /' /8 015 06/06/14 7N2 -R