HomeMy WebLinkAboutPP - 11061 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS11061 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 03-S-059 75cd EOL WP Covered Storage Storage Container Storage Storage / Work Area Storage / Work Area 30cd 30cd 0 Storage Lease Building Fire Alarm Plan 1/8" = 1' - 0" Una 1111.11 Covered Storage Office 3Ocd From FACP in Main Bldg. Toilet From J -box 11 IA Q 4 Sequence of Operation Manual Pulistation1 Smoke Detector Heat Detector System Trouble Activation of local alarm @ FACP LCD disp. & audible indication. 43I 02) Activate audible/visual devices. * * 0 0 Transmit alarm signal to central station. 0 0 Trouble Indication @ FACP LCD disp. & audible Indication. Transmit trouble signal to central station. **Detection devices in the lease building will only activate the audble/visual devices in that building. r--. CO Q Q Q Co © CO Q LI Lease Building © ©` ©` ©` 0 Lease Building a. 0 0 J U -J CO STROBI SYNCH MODULI 0 -L 01 0 Z STROBE SYNCH. MODULE 0 •C Z 0 Z E F E F E F `5E e'--( FJ E STROBE SYNCH. MODULE U 2 Exist. Main Bldg. Exist. FACP----10-1 I/O 110 I/O I/O CKT., CKT. CKT. CKT. I/O 110 (EXISTING) SILENT KNIGHT IFP -1000 ADDRESSABLE FIRE ALARM PANEL P Lease Building ) Riser Diagram Wire List Connect to U.L. Central Station for monitoring. Connect to DEDICATED 120 Vrms @ 60Hz, 2A A.C. Ckt. for primary power. SLC Loop (2) #18AWG. FPLR (Fire Rated Cable) N.A.C. #6 (2) #12AWG. FPLR (Fire Rated Cable) LCD Annuciator (4) #18AWG. FPLR (Fire Rated Cable) Vicinity Map Not to Scale m Underground Conduit NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systemz. Failure of test will result in $40 Re - Inspection Fee and termination of the testing. C'tt Aides oto rpl/ 5 L,0 h -e nems 40-C c -c 771. 1 t4 f-, >c,tot( eft✓eJ inA) k mated 4-0 sp ecq.(Gt 7 L/e.- it -co a rr oils. Symbol Legend CEO Fire Alarm Control Panel Remote LCD Keypad Annuclator 0 Addressable Manual Pullstation Analog/Addressable Photoelectric Smoke Detector O Addressable 135'Fixed Temp. Heat Detector Combination Horn/Strobe (cd . candlela rating of strobe light) wall mount @ 80' or 8' below ceiling, whichever Is lower Strobe Light (cd - candlela rating of strobe light) wall mount @ 80' or 8' below celMng, whichever is lower EOL Indicates End of Line Device WP Indicates Weatherproof Device E Indicates Existing Device ACCE ❑ , Without Comments As Noted In Red ❑ Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions tti these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. /473 By: ZC('f2 Date: q ti.44411.4fill i1 tet(. citid * Isis - tiiiti pct address for restoration, app tty aP_A,..1E11-110 MAR 2 7 2003 Project Name: Date: 3/26/03 Pacific Strapping Lease Building 11061 Tukwila International Blvd. Tukwila, WA 98168 Scale: As Shown System Type: FIRE ALARM Drawn By: J.F. Contractors ALARMCI055CW license # Approved By: Date Revision Date Revision ACE FIRE & 1-800-354-1555 SECURITY SYSTEMS A Division of Alarm Center, Inc. P.O. BOX. 3363 LACEY, WA. 98509-3363 SHEET NO. FA -1