HomeMy WebLinkAboutPP - 14121 TUKWILA INTERNATIONAL BLVD - UNKNOWN - PERMITS AND PLANS14121 TUKWILA INTERNATIONAL BLVD ASSOCIATED PERMITS 19-F-151 TUKWILA BUILDING zN� FA PLAN 1 L ❑ Without Comments ^pr As Noted in Red ❑ Per The Attached Letter These plans have beer. reviewed by The Tukwila Fire Prevention Bureau r• turn, lance with current City standards. Accer S.,oiectto errors and omissions which c. - )112F ,lniatrofs of adopted standards and r r -Sr., a, • Ability For the adequacy o` d.w resigner. ;.dditions, deleno- " lrawings after this date will voiu tI.• ''It`-equlre a resubmittal of r,:vis%- " 'yam= .,quent approval. Final acceptance is suujec,t and Inspection by The Tukwila Fire Prevention Bureau. Date: 15 -1 -1 9 By: /4_\)I NICET Certified ` FA LovddIV #124064 i‘\. Shawn A. Lehman Viec,-- —J Expires ll/1/2020, Fire Permit Number To schedule ire2p< cticrls coil 206-575-4407 Pf,]D JUL1:3 2019 TUKVIV � E 292 C7 J3�9 SHEET INDEX PAGE: DESCRIPTION FA1 COVER SHEET FA2 FIRE ALARM DETAILS FA3 CALCULATIONS FA4 FIRE ALARM PUN Firm Nome and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 TUKWILA BUILDING 14121 Tukwila International Blvd Tukwila, WA 98168 No. Revision/Issue Date No. Revision/Issue Date -.-.e,,. m.* This COVER SHEET Poi.p Nom. IA..l DM 07/15/2019 FA 1 WIRING LEGEND SYMBOL DESCRIPTION A 14 GAUGE 2 CONDUCTOR (NAC) B 16 GAUGE 2 CONDUCTOR (SLC) C 16 GAUGE 4 CONDUCTOR (S -BUS) 0 12 GAUGE 2 CONDUCTOR (NAC) E 14 GAUGE 2 CONDUCTOR (FPLR) F - CEILING MNT. FIRE ALARM HORN ONLY Ir CIRCUIT NUMBER © FIRE ALARM LEGEND SYMBOL DESCRIPTION IFArPI FIRE ALARM CONTROL PANEL 1-6A-1 FIRE ALARM ANNUNCIATOR HORN/STROBE POWER SUPPLY IPy.. Lryl y1N ICATES CANOO .4 1401i0pp/STROBE FIRE ALARM CONTROL PANEL #EINDICATE6. CANDFIA RRATINORN/STROBE F -I INDIOTES CMIDEUMRAT NGBE ONLY Oa c• •INDICATES CANDELRAT GROBE ONLY Ii WALL MNT. FIRE HARM HORN ONLY 01 CEILING MNT. FIRE ALARM HORN ONLY CD FIRE ALARM DELL © FIRE ALARM MANUAL PULL STATION © SMOKE DETECTOR O VPTINDDETEICATES CTOR C ADDYE CEILING 03 DUCT SMOKE DETECTOR g< DEAN SMOKE DETECTOR g< REAM REFLECTOR ® DRY FLOW SWITCH sF WATERFLOW SWITCH © HIGH/LOW NR pT TAMPER SWITCH IE POST INDICATOR VALVE N DUCT DETEOFRFOR n DUCT DETECTOR TEST SWITCH III INPUT MODULE 12 DUAL INPUT MODULE PN)N4 Nom-4NM 10 INPUT MONITOR MODULE P`a RELAY MODULE g CONTROL MODULE 10 -y y y- END OF LINE 655131OR CIRCUIT/ (1 ADOVE OGLING DEVICE (IP) WEATHER PROOF On LOW FREQUENCY (N) NEw CO EXISTING (R) RELOCATE NOTE: NOT ALL SYMBOLS ARE USED IN THESE DRAWINGS DEVICE HEIGHT SCHEDULE DEVICE HEIGHT OUTDOOR HORN/STROBE 86" HORN/STROBE BO" PULL STATION 45" FIRE ALARM CONTROL PANEL 60 - POWER SUPPLY 60" BELL 96" ANNUNCIATOR 80" GENERAL NOTES 1. FIRE ALARM SYSTEM 15 POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE OR SPECIFICATIONS AND CONTRACT DOCUMENTS. 2. ALL RACEWAYS MUST BE FREE OF MOISTURE 3. REFER TO DATA SHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE DEVICE MOUNTING ELECTRICAL BOXES. 4. AC VOLTAGE 15 NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING 5. UNRELATED (NON FIRE ALARM) WIRE SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRE 6. ALL CONTRACTOR FIELD WIRINO MUST ENTER ALARM CONTROL PANEL BACKBOX FOLLOWING POWER -LIMITING ANO NON POWER -LIMITING WIRING REQUIREMENTS. REFER TO INSTALLATION INSTRUCTIONS FOR MORE INFORMATION. 7. ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS. T -TAPPING OF ZONE AND SIGNAL CIRCUITS IS NOT PERMITTED. 6. REFER TO FACP MODULE DIAGRAMS. INCLUDED WITH FACP. FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. 9. ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS. AND GROUNDS. 10. ALL WIRING SMALL BE LABELED AND TAGGEO. 11. ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW -VOLTAGE WIRING. 12. 00 NOT USE FIRE ALARM CABINET A5 TERMINAL CABINET FIRE ALARM SYSTEM DESIGNED BY: KOT ELECTRIC LLC. EDGEWOOD, WA 253-737-7015 FIRE ALARM SYSTEM INSTALLED BY: KOT ELECTRIC LLC. EDGEWOOD. WA EQUIP. FOR FIRE ALARM SYSTEM SUPPLIED BY: SILENT KN1GHT INC. NORTHFORD. CT WA STATE ELECTRICAL CONTRACTORS NUMBER: KOTELEL827RC ♦ THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH T1-15 CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA SMOKE DETECTOR 2 PULL STATION 3 WATER FLOW 4 TAMPERS 5 PIV 6 DUCT DETECTOR 7 MAIN FLOOR SMOKE 8 ALT. FLOOR SMOKES er ABCDE KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 TUKWILA BUILDING 14121 Tukwila International Blvd NOTES: • Revision/Issue Dote • • • • • • • • • • No. Revision/Issue Dote ',mat A1Mw satµ t1Y FIRE ALARM DETAILS PN)N4 Nom-4NM • FA2 a� 07/15/2019aw. • • • • • • • • • • ABCDEF CHI SEQUENCE OF OPERATION MATRIX SCALE: N.T.S FIRE ALARM CONTROL PANEL; a 75 75 FA- 30 1. 75 5 15 15 15 15 15 I5 151, - IQ11x1 Iy,1°--'®-�"�"'Ij�""V V `� lT 0 0 V 0 SPARE RJ31X TELCO 120VAC FIRE ALARM RISER 4". AIF. N.T.S. (::fi:: Level IV 0124064 Shawn A. Lehman ve,„ a— 7 Expires 11/1/2020 /' Firm Name and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 TUKWILA BUILDING 14121 Tukwila International Blvd Tukwila, WA 98168 No. Revision/Issue Dote No. Revision/Issue Dote ',mat A1Mw satµ t1Y FIRE ALARM DETAILS PN)N4 Nom-4NM F FA2 a� 07/15/2019aw. Unimode 5 / MS -5024 Battery Calculation oI+M 8.004 Sot lnnl rsh es 0.direonv nMyntranmrs t -Y•'i .evet RegWeted Load M Starhdtry Pa{p 1 Davies Typo Main Circuit Board ADM -24 RZA-SF CAC -5F (draws no current) Number of Devices X x X X Currant (Amps) 0.123 0.006 Total CumM (Amps) 0.123 NACA-2F (1 max.) 2 -Mrs Detector Heads 4 r Detector Heads Sower Supervision Relays Additional Current Draw from 78.4 (non Blare) ,SUM COLUMN FOR STANDBY LOAD 0 16 0 x X X x x 0 0.04)005 a 0.025 0.0008 0.1238 • AMPS LIS -5024 Battery Calculation a aY t.a Is R.Y-R,R"...�4 by •�•W�➢My..t .� -.w .. �--- —"-- Regulated Load In ALARM .-- Page 2 Davies Type MAIN CIRCUIT BOARD ADM -24 (1 max.) RTA -5F (1 max.) CAC -5F (draws no current) NACA-2F (1 max.) 4 -wire Smoke Detectors Power Supervision Relays Programmable Relay(s) Notification Applianess(HSRC 75cd) Notification App6aoces(HSRC 15cd) Notification A596000es(STRC 30cd) Notification Appeances(STRC 15cd) ADDITIONAL CURRENT FROM TB -4 (ALARM CURRENT) Number of Devices 5 0 0 7 2 7 0 X x X x x x X X x X X X x Currant (Amps) 0.255 0.006 0.046 0 0.025 0.025 0.01 D. 148 0.082 0 065 0.061 Toni Current (Amps) 0.255 0.046 1.038 0.164 0.085 0.427 SUM COLUMN FOR LOAD IN ALARM 1 1 2.0131 • !MAPS MS -5024 Battery Calculation M taw 0.4Y vr'M,,, rears o-nl.Jmt' I C*6000on in Total Sheet Pape 3 Use the total standby and alarm toad currents calculated In tables A -2A and A-213 for the following battery calculations Standby Load Current (Amps) Alarm Load Current (Amps) Add Standby end Alarm Load for Required Ampere Hour Battery Multiply by file Derating Factor of 12 Total Ampere Hours Required 0 .1236 X 2.013 X Required Standby Time in Homs (24 or60 Hrs.) 24 a 2.9772 Required Alarm Time in Hours (5 minutes = 0.084) 0.064 • 0.169092 3.140292 3.7683504 IThe battens can be housed n the pmol cabinet The panel is capable of charging the required 601401las iThe total NAC output current is within the limitations of the panel NICET Certified FA Level IV 0124064 Shawn A. Lehman Expires 11/1/2020 4� I#' Firm Nome and Address KOT ELECTRIC LLC. 1513 105TH AVE CTE EDGEWOOD, WA 98372 TUKWILA BUILDING 14121 Tukwila International Blvd Tukwila, WA 98168 No. No. rroPa want Revision/Issue Revision/Issue Date Date $104! lea CALCULATIONS MJ.ot Ann. 07/15/2019 FA3 28' 28' 32' 4' 9' 32' 4' 9' 32' -17 10' STORAGE C HF —12'—i KITCHEN r Alf..s�_t 4.1F F 2N-1 38' MARKET —e — PATIENT ROOM PATIENT ROOM B �1 r PATIENT ROOM c PATIENT RObM r e 6� 1 10 FACP 70 rACP -4' RESTROOM B OFFICE 10' FIRE ALARM PLAN SCALE: 1/4' -1* -O• A 10' 32' B TO rACF B-0 TO ;ACA STORAGE �15 PAT1ENt ROOM A4 15 PATIENNROOM z�t5✓`��' V r FA -2 — 4' — — 8'6" 15 PATIENTROOM A�w 615 PATIENT ROOM 5 A A �,I 0 Y 5 H �� ; RESTROOM A OFFICE 10' FIRE ALARM PLAN TO FRCP -- 9-- A 75 15 O7- A TO FACP SCALE 1/4•-1=0" 11Ar F WALL — 12'-1 KITCHEN RETAIL J B OFFICE // NICET �{/ Certified FA Level IV #124064 Shawn A. Lehman Ve...„61-7 Expires 11/1/2020 , II .... Firm Nome and Address KOT ELECTRIC LLC. 1513 105TH AVE CT E EDGEWOOD, WA 98372 TUKWILA BUILDING 14121 Tukwila International Blvd Tukwila, WA 98168 No. Revision/Issue Dote No. Revision/Issue Dote Roi.o A00.o -A..t 181. FIRE ALARM PLAN 17,0)001 No.* 51.1 °°" 07/15/2019 FA4