PP - 730 ANDOVER PARK EAST - UNKNOWN - PERMITS AND PLANS
730 ANDOVER PARK EAST ASSOCIATED PERMITS 09-F-159 11-5-221 09-F-135 SCOPE OF AIOR< I. THE SCOPE OF THIS PROJECT 15 TO INSTALL A FIRE SIGNAL EXPANDER, NOTIFICATION AND ADDRESSABLE DEVICES FOR THE PURPOSE OF TENANT IMPROVEMENT. GENERAL NOTES: I. INSTALLATION SHALL SE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC AND CONTRACT DRAWINGS. 2. AS-BUILTS ARE REQUIRED AT TIME OF AJH ACCEPTANCE. SFSM REQUIRED ELECTRICAL RED LINES WITHIN TWO WEEKS PRIOR TO AHJ TESTS. 3. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH SFSM PROJECT MANAGER. ALL SFSM FIELD SERV I GES MUST BE SCHEDULED WITH SFSM PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS ADVANCE NOTICE. 4. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY SFSM ALARM TECHNICIAN. 5. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF SFSM ALARM TECHNICIANS. 6. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ15 TESTS. 1. WIRING ROUTING 15 DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. S. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. Q. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM GABLE. 10. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL AND ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL AND ARCHITECTURAL PLANS. II. FIELD VERIFY WATERFLOW, SMOKE DAMPERS, AND DUCT DETECTORS LOCATIONS. 12. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC. AND FAN CONTROL. 13. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY AIR DIFFUSER. 14. WALL MOUNTED AUDIBLE/VISUAL APPLIANCES SHALL BE MOUNTED IN SUCH THAT THE ENTIRE LENS 15 NOT LESS THAN SO" AND NOT GREATER THAN 0i6" ABOVE THE FINISHED FLOOR. 15. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE NOT LESS THAN 3 1/2 FT. AND NOT MORE THAN 4 1/2 FT. ABOVE THE FINISHED FLOOR. 16. NO DETECTOR SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION GLEAN -UP. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO GLEAN -UP MUST BE GLEANED OR REPLACED AND WILL BE I NVO I GED ON A TIME AND MATERIAL BASIS. 11. A DEDICATED BRANCH CIRCUIT OF ONE OF THE FOLLOWING SHALL SUPPLY PRIMARY POWER. A) COMMERCIAL LIGHT AND POWER. B) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATIONS IS ON DUTY AT ALL TIMES. G) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT ARRANGED FOR COGENERATION WITH COMMERCIAL LIGHT AND POWER WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATION 15 ON DUTY AT ALL TIMES. IS. ALL C I RCU I TS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS, AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO SFSM ALARM FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP AND CHECKOUT. I'3. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS 15 ALLOWED PROVIDING A SPLICE 15 PROFESSIONALLY INSTALLED, POLARITY 15 OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. GABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH GABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FACP. /1.-ARIF I. A PRE -CONSTRUCTION MEETING WILL BE HELD TO DETERMINE WHAT AREAS WILL NEED TO BE CLEARED FOR LIFT ACCESS. 2. OUR PRICE IS BASED ON PROVIDING TIMELY CLEAN UP AND REMOVAL OF SFSM DEBRIS FROM THE JOB SITE BY OUR PERSONNEL. 3. THIS PROPOSAL 15 COOP FOR 30 DAYS FROM THE DATE OF THIS PROPOSAL. 4. ALL WORK WILL BE PERFORMED DURING NORMAL BUSINESS HOURS, MONDAY THROUGH FRIDAY, 1:OOAM TO 5:0OPM. 5. ALL FIRE ALARM WIRES WILL BE INSTALLED PER THE NATIONAL ELECTRICAL CODE (NEC), THE STATE OF WASHINGTON ELECTRICAL CODES. 6. THIS PROPOSAL 15 BASED ON FREE AND UNHINDERED ACCESS THROUGHOUT THE FACILITY INCLUDING ACCESS TO ALL GROUND SPACE BENEATH OUR DEVICES AND WIRING ROUTES. EXCL S ONS: I. SERVICE OR REPAIR OF ANY EXI STI NCS SYSTEM DEVICES DUE TO NONPUNGTI ONAL I TY. 2. SERVICE OR. REPAIR OF ANY EXISTING SYSTEM FIELD WIRING DUE TO NONFUNCTIONALITY. 5. KNOX BOX, IF REQUIRED, PROVIDED BY THE OWNER. low z - t O 0'-4" MIN. ACCEPTED HERE NEVER HERE 1\-- WALL MOUNTED SMOKE OR HEAT DETECTOR DETECTOR AIR DIFFUSER CEILING 3'-O" MIN. SMOKE DETECTOR NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. t 5'-0" MAX.,, 4'-6" MAX FINISHED FLOOR -` 4 i LENS-�- !t1 SPAG I N0 DETAILS r 1 WORK AREA • 111111 • •111111 81,. 111111We • r - SrE F A\ • 111111 1,0 N.T.S. Et) NEW DEVICES I L r 35 U F 6E OI:MOI TS 01:M02 01:M03 01:M04 TS M FS - i M DD OI:MI5 OI:M05 0I:M06 M M M DD DD DD 01:M0? M DD 01:M06 0I : MO4 M M DD NEW DEVICES DD 0I:MI0 M DD 0I:MI1 M DD 01:MI2 M DD FRCP 6 GG A3 -I 15cd -� GKT-3 .I/6mA EOL S2 GG S2 GG 15cd 81-2 51-3 51-4 BI -5 I SI- INF FSE AI -I AI -2 AI -5 AI -4 AI -5 AI -6 _ M II5cd IIScd II5cd 115cd II5cd II5cd FAGP GKT-I .218mA .218mA .218mA .218mA .218mA .218mA EOL A2 -I A2-2 A2-5 A2-4 A2-5 A2-6 15cd 15cd II5cd 115cd a5cd II5cd • • A2-7 -15cd FACP GKT-2 .066mA .066mA .218mA .218mA .Ia4mA .218mA .I"16mA EOL I15cd I15cd IIScd 115cd n FSE CKT-I .218mA .218mA .218mA .218mA .218mA .218mA EOL 52-1 52-2 52-5 52-4 I5cd IIScd 115cd 15cc1 52-5 I IOcd FSE • © © >E .066mA .216mA .218mA .I76mA .2I2mA EOL CKT-2 -------------------------------------------- R I SER SETA I I. ALL MONITOR MODULES AND THE FIRE ALARM CONTROL PANEL ARE EXISTING. 2. ALL PULL STATIONS WILL SE ADDRESSED AT THE TIME OF INSTALLATION AND AND WILL BE NOTED ON AS -BUILT PLANS. 3. A ZONE LIST WILL BE INCLUDED ON AS -BUILT PRINTS. C/O \ST.dC7ON NO S -S1t - cr.w r+.r..* Volum- C- Project Name 'ANDOVER PARK E. SUITE 730 1 Standby Hoursa 60 r a r•e n t Y Project ID:1FA9063 J Alarm Mins:1 5 1 0.000 Prepared By:iSCOTT JERKE 1 Derating Factor:l 1.2 1 FP 00 Cs Date:110/5/2009 1 Voltage Drop Warning .,...�. �..:i Threshold %.1 20. 1 0.000 Pane! ID: 15499 1 Model: 5499 Power Expander Max NAC Current 3.0 Amps Panel ID: (IFP -100 IDP Devices 1. Model: IFP -100 Add. Fire Alarm Control Panel Max NAC Current 3.0 Amps Location: 'RISER ROOM SUITE 720 1 Volts: 24 VDC Max Panel Current 5.0 Amps 5499 Ckt.# Circuit Name oty Current: Draw Wire AWG Ohms Per Length(ft) Actual. Volts, %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL IFP -100. IFP -100 Fire Panel t 0.170 '0.325. 5499 Circuit 1 SLC -DEV Photo.lon,Heat 1 0.000 0.000 394 IOP Beam Beam detector 0.000 : 0.000 5499 Circuit 2 IPD Duct Non Relay 0.000 0:000 293 IPD Duct With Relay 0.000 0.000 5499 Circuit 3 IDP IDP Acclimate ROR 0.000. , 0000.. N IDP Monitor,Contrd Module 13 0.004 0.004 5499 Circuit 4 IDP Monitor -2, 0.000 0.000 Q IDP Monitor -10 0.000 0.000 5499 Aux Power Out IDP Relay -6, 0.000 0.000 000' IDP Control -6 0.000 0.000 0,075 IDP Pull 6 0.002 0.002 24 SLC -ACC SSB501BHT Sounder 0.000 0.000 1.800 SSB224RB Relay Base 0.000 0.000 2.00 IDP RTS451 Keyl 0.000 0.000 2.40 IDP RA400Z 0.000 0.000 675' IDP -Iso Isolator Module 0.000 0.000 SPARE SSB224BI Isolator Base 0.000 0.000 FF RA -100 LCD Remote Annunc 0.000 0.000 I 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 RPS -1000 Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0,000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 PGM -1l0 #1 Notification Appl Circuit 0.000 1.308 #14 Solid 2.52 443 2.23 17.48 14,32% PGM -I/O #2 Notification Appl Circuit 0.000 1.156 #14 Solid 2.52 360 1.81 18.30 10.28% PGM4IO #3 Notification Appl Circuit 0.000 0.176 #14 Solid 2.52 109 0.55 20.30 0.47% PGM -1/0 #4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% PGM -1/0 #5 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% PGM -/O #6 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Total Standby Current (Amps) 0.176 2.971 Total Alarm Current (Amps) Standby Time In Hours 60 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 10.570 0.248 Total Alarm AN Required Total Combined AH Required 10 82 Command Shortcuts Multiply By The Derating Factor Minimum Battery AmpHours Required 1.20 12.98 Configure Circuits 1 1 Print Page 1 fI -S1t Panel ID: IFP-100IDP Devices 1 1 1 Project Name:IANDOVER PARK E. SUITE 7301 Standby Hours:1 24 KNY 1;:itil G111' Project ID:1FA9063 1 Alarm Mins:1 5 0.000 Prepared By:1SCOTT JERKE I Derating Factor' 1.2 1 5499 Power Expander Calouidilons' ; ', Date:110/5/2009 I Voltage Drop Warning Yecion 12.19.08 Threshold %. 1 20 1 0.000 Pane! ID: 15499 1 Model: 5499 Power Expander Max NAC Current 3.0 Amps Location: 'SUITE 770 1 Volts: 24 VDC Max Panel Current 9.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts © %Drop Standb Alarm & Type 1000 Ft. One -Way Ohms EOL 5499 5499 Pwr Module 1 1 0.075 0.205 0.000 NAC #1 5499 Circuit 1 0.000 1.308 #14 Solid 2.52 394 1.99 17.80 12.73% NAC #2 5499 Circuit 2 0.000 0.890 #14 Solid 2.52 293 1.48 19.09 6.44% 'JACi43 5499 Circuit 3 0.000 0.000 #14 Solid 2.52 N 0.00 20.40 0.00% NAC 04 5499 Circuit 4 0.000 0.000 #14 Solid 2.52 Q 0.00 20.40 0.00% Aux 5499 Aux Power Out 0.000 0.000 #14 Solid 2.52 000' 0.00 20.40 0.00% Total Standby Current (Amps) 0,075 2.403 Total Alarm Current (Amps) 000' Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) W Total Standby AH Required 1.800 0.200 Total Alarm AH Required 000' Total Combined AH Required 2.00 Wire resistances ere based upon an ambient temperature of 72 degrees F. Bemuse of the minimal difference between solid and stranded wire no differential wes made. Multiply By The Derating Factor 1.20 Minimum BatteryAmpHours Required 2.40 Project information Protect Name: ANDOVER PARK E. SUITE 730 Prepared By: SCOTT JERKE Project ID: FA9063 Date: 10/5/2009 Ckt Number. PGM -1/0 #1 Ckt. Name: Notification Appl Circuit Panel ID: IFP-100IDP Devices I/O Usei Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 6 PC2R/115 0.000 0.218 0.000 1.308 0.000 Unused 0.000 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 000' 14 0.000 0.000 0.000 0.000 Totals 0.000 1.308 Ckt. Number. PGM -I/O #2 Panel ID: IFP -100 IDP Devices _ Ckt. Name: Notification App' Circuit I/O Use: Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 PC2R/115 0.000 0.218 0.000 0.654 1 PC2R/95 0.000 0.194 0.000 0.194 1 P2R/75 0.000 0.176 0.000 0.176 2 SCR/15 0.000 0.066 0.000 0.132 G 16/2 ADDRESSABLE FPLP 000' 14 0.000 0.000 Totals 0.000 1.156 Ckt. Number. PGM -I/O #3 Panel ID: IFP -100 IDP Devices - Ckt. Name: Notification Appl Circuit I/O Use:I Notification Appl Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 P2RK/75 0.000 0.176 0.000 0.176 1 Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 2 Unused 0.000 0.000 0.000 0.000 G 16/2 ADDRESSABLE FPLP 000' 14 0.000 0.000 Totals 0.000 0.176 Project Information [ Project Name: ANDOVER PARK E. SUITE 730 Prepared By: SCOTT JERKE Project ID: FA9063 Date: 10/5/2009 Ckt Number. NAC #1 Panel ID: 5499 Ckt. Name: 5499 Circuit 1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 6 PC2R/115 0.000 0.218 0.000 1.308 1 Unused 0.000 0.000 0.000 0.000 1 Unused 0.000 0.000 0.000 0.000 2 Unused 0.000 0.000 0.000 0.000 G 16/2 ADDRESSABLE FPLP 000' 14 0.000 0.000 Totals 0.000 1.308 Ckt Number. NAC #2 Panel ID: 5499 Ckt. Name: 5499 Circuit 2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 P2R/75 0.000 0.176 0.000 0.176 1 SCR/15 0.000 0.066 0.000 0.065 1 PC2R/110 0.000 0.212 0.000 0.212 2 PC2R/115 0.000 0.218 0.000 0.436 G 16/2 ADDRESSABLE FPLP 000' 14 0.000 0.000 Totals 0.000 0.890 GA,GUvAiIONS SYMBOLS DESCRIPTION QTY PART SYM DESCRIPTION TOTAL FT. FIRE ALARM CONTROL PANEL 1 A 16/2 CONVENTIONAL FPLR 000' 5 16/2 CONVENTIONAL LOOP FPLR 000' G 16/2 CONVENTIONAL FPLP 000' D 16/2 CONVENTIONAL LOOP FPLP 000' E 16/2 ADDRESSABLE FPLR 000' F 16/2 ADDRESSABLE LOOP FPLR 000' G 16/2 ADDRESSABLE FPLP 000' 14 16/2 ADDRESSABLE LOOP FPLP 000' 1 12/2 NOTIFICATON FPLR 000' J 12/2 NOTIFIGATON LOOP FPLR 000' K 12/2 NOTIFIGATON FPLP 000' L 12/2 NOTIFICATON LOOP FPLP 000' M 14/2 NOTIFICATON FPLR 154iG1' N 14/2 NOTIFICATON LOOP FPLR 000' O I4/2 NOTIFIGATON FPLP 000' P 14/2 NOTIFICATON LOOP FPLP 000' D Q 16/4 ANNUNCIATOR FPLR 000' 6 R 16/4 ANNUNCIATOR FPLP 000' F 5 14/2 POWER CIRCUIT 24VDC FPLR 000' E T 14/2 POWER CIRCUIT 24VDC LOOP FPLR 000' U 14/2 POWER CIRCUIT 24VDC FPLP 000' FARENHYT V 14/2 POWER GIRGUIT 24 LOOP FPLP - 000' W 16/4 5BU5 000' X 14/2 FSE TRIGGER 000' Y I5/6 REMOTE TEST SWITCH 000' Z 16 AWG TFFN 000' AA 14 AWG THWN 000' BB 16/4 ADDRESSABLE FPLR 675' CG 18/4 FPLR SYNC MODULE 214' DD SPARE 000' EE SPARE 000' FF SPARE 000' I E ,Ea-----\ SYMBOLS DESCRIPTION QTY PART MANUFACTURER MOUNTING DATE: FIRE ALARM CONTROL PANEL 1 E IFPI00 FARENHYT FAGI063 FACP FA 1 OF 2 FIRE SIGNAL EXPANDER I 54ciq SILENT KNIGHT FSE ANNUNCIATOR PANEL E RA -1000R SILENT KNIGHT l FAA I^IFATHER PROOF HORN / STROBE I P2RK SYSTEM SENSOR 4 SQUARE DEEP W/ WPBS 0 CEILING STROBE 5 SCR SYSTEM SENSOR 4 SQUARE DEEP IN/ SINGLE GANG CEILING HORN / STROBE Ia PG2R SYSTEM SENSOR 4 SQUARE DEEP W/ SINGLE GANG I WALL HORN / STROBE 2 P2R SYSTEM SENSOR 4 SQUARE DEEP IN/ SINGLE GANG D MANUAL PULL STATION 6 IDP -PULL -5A FARENHYT F ©P PHOTO SMOKE DETECTOR E IDP -PHOTO FARENHYT MONITOR MODULE E IDP -MON FARENHYT M DUCT DETECTOR E BY OTHERS DD DUAL SYNC MODULE 2 MDLSR i SYSTEM SENSOR S2 1:7EVI C/E LEGEN 7 -so iindavw Pi., E. ACCEPTED Q Without Comments gr As Noted in Red Ci Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totaily Mil the designer. Additions, deletions or revisions to these drawings after this date will void this accepaince and will require'a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Are Prevention Bureau. Date: /e. -Q gy: / � ( TtJKWILA. FIRE DEPARTMJNI Please. call: 575-4407 acid give this job No.09-f-/s5 and exact address for shut, clown or restoration apvruval - tk$4 1 l w P if.3A l S+-►obe 0 --. Px�trior -racIhc) s-6-eej-. sy e�.//�-Iv b -e Ti e(j A +0 ArerO,Orictte. WC44Cr MOW z0% Q- .1714 - i 714 tkii.'‘S dew,e.es 4o l .e po'tvd wddre»c6k 1oC�,i(y CtJ M- Ctt.-1.0.( 5•}44 -roti ^ pvai. defect -ors- •i -o L -e Sie.7./.501 --1►,�}r ll re 1a,, e . L. e .p,'s C6- ctSQ,re dvGi- de-fey/ors. L- 5414 Ui,r 4 (er (lltt iQ cAli v -p 01, F4 c/t 6-1C41'to( /}Girt✓•7' 1,etw1(?a- . -1:71,31-41( i�lY� �Cf: k o2c Qo7-. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prig- to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. AIDFailure of test wilt�result in. a Re -inspection Fee and 1 termination of the tag OCTt 2009 Tukwila Fire SMITH FIRE SYSTEMS MANAGEMENT, LLC. 1106 54TH AVE EAST TACOMA, WA 98424 SMITHFS946LO OFFICE (253) 248-2000 - FAX (253) 926-0726 A SUBSIDIARY COMPANY OF SMITH FIRE SYSTEMS REVISIONS: RESUE3M I TTAL c1/5/0Q CONTRACT WITH: E3REKKE PROPERTIES PO E3OX 287 MED I NA, WA gS03cf JOHN EBREKKE PHONE 425-451-1151 PROJECT MANAGER: HOWARD W I LL I AMSON 253-248-2003 HWILLIAMSON@SMITHF 1RE.GOM SYSTEMS DESIGNER: SCOTT JERKE SJERKE@ SM I THE I RE.GOM PROJECT: ANDOVER PARK EAST SUITE 150 730 ANDOVER PARK E. TUKWILA, WA ci'SISS PARCEL# 2 62304c 101 DESIGNER: SCOTT JERKE DATE: ci/5/0cl AHJ: TUKWILA JOB #: FAGI063 SHEET #: FA 1 OF 2 TO CENTRAL STATION REMOTE ANNUNCIATOR FIRE ALARM WIRE LEGEND DESIG. DESCRIPTION A 16/2 FPLP INITIATING CIRCUIT WIRING B 14/2 FPLP INDICATING CIRCUIT WARNING FIRE ALARM LEGEND SYMBOLS DESCRIPTION QTY PART MANUFACTURE FIRE ALARM CONTROL PANEL E IFP -100 FARENHYT FACP Y I REMOTE ANNUNCIATOR E RA -1000R FARENHYT ANN © SMOKE DETECTOR E IDP -PHOTO FARENHYT MONITOR MODULE 1 IDP -MON. ` FARENHYT- ARENHYTDD Voltage Drop Warning DUCT DETECTOR E Threshold % . DD MODELRA.1000R P FIRE ALARM LEGEND FACP #16/4 PHONE LINE #1 PHONE LINE #2 120 VAC S (DEDICATED CKT.) 1 r1 Farenhyt IFP -100 DUAL LINE DIALER ®SILENT KNIGHT N.T.S. 01:S01 01:M01 01:M02 01:M03 SLC I '"' TS TS WF SC NAC -1 #16/2 NAC -2 #14/2 NAC -3 F #14/2 NAC -4 #14/2 BATTERY BATTERY P #14/2 SUITE 720 FOR FUTURE USE SUITE 730 FOR FUTURE USE SUITE 770 FOR FUTURE USE SUITE 790 FOR FUTURE USE FIRE ALARM RISER CEILING FINISHED FLOOR 2 rn z 0) NEW DEVICE 01:M04 01:M05 01:M06 01:M07 01:M08 01:M09 01:M10 01:M11 01:M121 01:M131 © © a ® © © © ©�©; N.T.S. LENS CEILING OPERATABLE AREA FINISHED FLOOR -N,` SIDEWALL ri SPACING DETAILS N.T.S. 0'-4" MIN. CEILING ACCEPTABLE HERE NEVER HERE TOP OF DETECTOR ACCEPTABLE HERE NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. tom war FIRE ALARM CALC N.T.S. z 2 1 0 0 SIDEWALL /. / / / / n WORK AREA SCOPE OF WORK: 1. THE SCOPE OF THIS PROJECT IS TO ADD A MONITOR MODULE TO AN EXISTING DUCT DETECTOR FOR THE PURPOSE OF TENANT IMPROVEMENT. GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC AND CONTRACT DRAWINGS. 2. AS-BUILTS ARE REQUIRED AT TIME OF AJH ACCEPTANCE. SFSM REQUIRED ELECTRICAL RED LINES WITHIN TWO WEEKS PRIOR TO AHJ TESTS. 3. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH SFSM PROJECT MANAGER. ALL SFSM FIELD SERVICES MUST BE SCHEDULED WITH SFSM PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS ADVANCE NOTICE. 4. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY SFSM ALARM TECHNICIAN. 5. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF SFSM ALARM TECHNICIANS. 6. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ'S TESTS. 7. WIRING ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 8. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 9. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 10. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL AND ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL AND ARCHITECTURAL PLANS. 11. FIELD VERIFY WATERFLOW, SMOKE DAMPERS, AND DUCT DETECTORS LOCATIONS. 12. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 13. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY AIR DIFFUSER. 14. WALL MOUNTED AUDIBLENISUAL APPLIANCES SHALL BE MOUNTED IN SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80" AND NOT GREATER THAN 96" ABOVE THE FINISHED FLOOR. 15. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE NOT LESS THAN 3 1/2 FT. AND NOT MORE THEN 41/2 FT. ABOVE THE FINISHED FLOOR. 16. NO DETECTOR SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A TIME AND MATERIAL BASIS. 17. A DEDICATED BRANCH CIRCUIT OF ONE OF THE FOLLOWING SHALL SUPPLY PRIMARY POWER. A) COMMERCIAL LIGHT AND POWER. B) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATIONS ON DUTY AT ALL TIMES. C) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT ARRANGED FOR CONGENERATION WITH COMMERCIAL LIGHT AND POWER WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATION IS ON DUTY AT ALL TIMES. 18. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS, AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO SFSM ALARM FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP AND CHECKOUT. 19. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FACP. I LI ANDOVER PARK E r SITE PLAN N.T.S. ACCEPTED t ( Without Comments o As Noted in Red O Per The Attached Letter -se plans have been reviewed by The Tukwila Fire -ention Bureau for conformance with current City ndards. Acceptance is subject to errors and •:,;lissions which do not authorize violations of adopted 3ndards and ordinances. The responsibility for the ,..iequacy of design rests totally with the designer. ;..lditions, deletions or revisions to these drawings after tris date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: X -a7 - d ct By: 4"1"-% J l TUKWILA FRE DEPART Please cauls 575-440Z end give this job and exact address for shut• down orrest;:;ration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing. LE PAID AUG 2 5 2009 AHJ TUKWILA Tukwila Fire 717,- PARCEL# 2623049101 SHEET' # FA 1 OF 2 U) Z 0 Z O H 0 tz 0 ci) w 0 w I- 0 CONTRACT WITH U) IA O co Oco cc 00) W00� N Wmo� crow mo PROJECT MANAGER : PHIL HUNTER 0 0 (o 9 o) rn 0 CO Z▪ < W • W 1- Z W 0 w 0 0 C-5 - J J O Z (0 w o 2 Cr) ¢wo_ Z CO 1"- < w rn Qz C' - LO woow a DC L 1- z I- 0 kil ' f 1 a L i. FAX: ( 253) 926 - 2350 o (o N 0) N to m O co (1) () W ui cc co a. 13- OCw Q >� > 0 O Zz d < N- H DESIGNER: SCOTT JERKE DATE: 2/20/09 JOB # FA9063 - Global Project Values. ` Farenhyt Project Name: ANDOVER PARK EAST #730 Standby Hours: 24 Y I Project ID: FA9063 Alarm Mins: 5 Prepared By: SCOTT JERKE Derating Factor: 1.2 IFP 100 Calculations t Date: 8/20/2009 Voltage Drop Warning Threshold % . 10 Panel ID: IFP -100 Model: IFP -100 Max NAC Current: 3.0 Amps Location: RISER ROOM SUITE 720 Volts: 24 VDC Max Panel Current: 6.0 Amps Current Draw Ckt.# Circuit Name Qty Standby Alarm Wire AWG Ohms Per Length(ft) Actual Volts @ ° & T +e 1000 Ft. One-Wa Ohms EOL°Drop IFP -100 IFP -100 Main Control 1 0.206 0.356 SLC -DEV Addrsbl SLC Devices 14 0.001 0.008 RA -1000R LCD Remote Annunc 1 0.020 0.025 5824 Serial/Parallel Module 0.000 0.000 RPS -1000 Power Expander 0.000 0.000 5865-4 LED Annunciator (4G) 0.000 0.000 5865-3 LED Annunciator (3G) 0.000 0.000 5880 LED Driver Module 0.000 0.000 Other Other SD -Duct Duct Hsg w/Relay 0.000 0.000 5883 Relay Module 0.000 0.000 NAC #1 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC #2 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC #3 Notification Appl Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% NAC #4 Notification Appl Circuit 0.000 0.000 #12 Solid 2.52 0.00 20.40 0.00% Total Standby Current (Amps) 0.227 0.389 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 5.442 0.032 Total Alarm AH Required Total Combined AH Required 5.47 Command Shortcuts Multiply By The Derating Factor 1.20 Minimum Battery AmpHours Required 6.57( Configure Circuits 1 ( Print Page FIRE ALARM CALC N.T.S. z 2 1 0 0 SIDEWALL /. / / / / n WORK AREA SCOPE OF WORK: 1. THE SCOPE OF THIS PROJECT IS TO ADD A MONITOR MODULE TO AN EXISTING DUCT DETECTOR FOR THE PURPOSE OF TENANT IMPROVEMENT. GENERAL NOTES: 1. INSTALLATION SHALL BE ACCOMPLISHED IN STRICT COMPLIANCE WITH NFPA, LOCAL AND STATE AHJ'S, NEC AND CONTRACT DRAWINGS. 2. AS-BUILTS ARE REQUIRED AT TIME OF AJH ACCEPTANCE. SFSM REQUIRED ELECTRICAL RED LINES WITHIN TWO WEEKS PRIOR TO AHJ TESTS. 3. AGREEMENT AND CONFIRMATION OF ALL MILESTONE EVENTS WILL BE MADE WITH SFSM PROJECT MANAGER. ALL SFSM FIELD SERVICES MUST BE SCHEDULED WITH SFSM PROJECT MANAGER WITH A MINIMUM OF TEN WORKING DAYS ADVANCE NOTICE. 4. A SET OF INSTALLATION AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY SFSM ALARM TECHNICIAN. 5. FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF SFSM ALARM TECHNICIANS. 6. THE SYSTEM SHALL BE MONITORED BY A U.L. LISTED MONITORING STATION BEFORE AHJ'S TESTS. 7. WIRING ROUTING IS DIAGRAMMATIC IN NATURE ONLY AND NOT INTENDED FOR ACTUAL CONDUIT ROUTING. 8. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ. 9. NO LINE VOLTAGE IN SAME CONDUIT AS POWER LIMITED FIRE ALARM CABLE. 10. VERIFY ALL LOCATIONS OF DEVICES WITH ELECTRICAL AND ARCHITECTURAL PLANS. SCALE AND PLACE ALL DEVICES PER ELECTRICAL AND ARCHITECTURAL PLANS. 11. FIELD VERIFY WATERFLOW, SMOKE DAMPERS, AND DUCT DETECTORS LOCATIONS. 12. FIELD VERIFY ALL WIRING LOCATIONS AND REQUIREMENTS FOR HVAC AND FAN CONTROL. 13. SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 36" OF ANY AIR DIFFUSER. 14. WALL MOUNTED AUDIBLENISUAL APPLIANCES SHALL BE MOUNTED IN SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80" AND NOT GREATER THAN 96" ABOVE THE FINISHED FLOOR. 15. THE OPERABLE PART OF EACH MANUAL FIRE ALARM BOX SHALL BE NOT LESS THAN 3 1/2 FT. AND NOT MORE THEN 41/2 FT. ABOVE THE FINISHED FLOOR. 16. NO DETECTOR SHALL BE INSTALLED UNTIL AFTER FINAL CONSTRUCTION CLEAN-UP DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO CLEAN-UP MUST BE CLEANED OR REPLACED AND WILL BE INVOICED ON A TIME AND MATERIAL BASIS. 17. A DEDICATED BRANCH CIRCUIT OF ONE OF THE FOLLOWING SHALL SUPPLY PRIMARY POWER. A) COMMERCIAL LIGHT AND POWER. B) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATIONS ON DUTY AT ALL TIMES. C) AN ENGINE -DRIVEN GENERATOR OR EQUIVALENT ARRANGED FOR CONGENERATION WITH COMMERCIAL LIGHT AND POWER WHERE A PERSON SPECIFICALLY TRAINED IN ITS OPERATION IS ON DUTY AT ALL TIMES. 18. ALL CIRCUITS WILL BE PROPERLY TAGGED AND TESTED FOR OPENS, SHORTS, GROUNDS, AND PROPER "END -OF -LINE" RESISTANCE. EACH CIRCUITS METER READING MUST BE DOCUMENTED AND PRESENTED TO SFSM ALARM FIELD TECHNICIAN UPON ARRIVAL ONSITE FOR STARTUP AND CHECKOUT. 19. NO TAPPING OF SIGNALING OR INITIATING ZONE CIRCUITS ARE ALLOWED. T -TAPPING OF STYLE 4 ADDRESSABLE CIRCUITS IS ALLOWED PROVIDING A SPLICE IS PROFESSIONALLY INSTALLED, POLARITY IS OBSERVED AND SHIELDS ARE CONTINUOUS AND FREE OF GROUNDS. SHIELDS MUST BE TERMINATED AT FACP ONLY. CABLE SHIELDS SHALL BE SPLICED TOGETHER AT EVERY JUNCTION BETWEEN THE FACP AND THE LAST DEVICE ON EACH CABLE RUN. SHIELDS AND OTHER FIRE ALARM CONDUCTORS (EXCEPT POWER GROUNDS) SHALL BE INSULATED AND COMPLETELY FREE FROM CONDUIT OR EARTH GROUNDS. SHIELDS WILL BE TIED TO GROUND ONLY AT THE FACP. I LI ANDOVER PARK E r SITE PLAN N.T.S. ACCEPTED t ( Without Comments o As Noted in Red O Per The Attached Letter -se plans have been reviewed by The Tukwila Fire -ention Bureau for conformance with current City ndards. Acceptance is subject to errors and •:,;lissions which do not authorize violations of adopted 3ndards and ordinances. The responsibility for the ,..iequacy of design rests totally with the designer. ;..lditions, deletions or revisions to these drawings after tris date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: X -a7 - d ct By: 4"1"-% J l TUKWILA FRE DEPART Please cauls 575-440Z end give this job and exact address for shut• down orrest;:;ration approval. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result In a Re -inspection Fee and termination of the testing. LE PAID AUG 2 5 2009 AHJ TUKWILA Tukwila Fire 717,- PARCEL# 2623049101 SHEET' # FA 1 OF 2 U) Z 0 Z O H 0 tz 0 ci) w 0 w I- 0 CONTRACT WITH U) IA O co Oco cc 00) W00� N Wmo� crow mo PROJECT MANAGER : PHIL HUNTER 0 0 (o 9 o) rn 0 CO Z▪ < W • W 1- Z W 0 w 0 0 C-5 - J J O Z (0 w o 2 Cr) ¢wo_ Z CO 1"- < w rn Qz C' - LO woow a DC L 1- z I- 0 kil ' f 1 a L i. FAX: ( 253) 926 - 2350 o (o N 0) N to m O co (1) () W ui cc co a. 13- OCw Q >� > 0 O Zz d < N- H DESIGNER: SCOTT JERKE DATE: 2/20/09 JOB # FA9063 • AREA OF WORK 41111011 NEW RESTROOM it EXISTING RESTROOM FIRE SPRINKLER PLAN NORTFI � SCALE: 1/4" =1'-0" DRAWING SYMBOLS SPRINKLER PIPE LEGEND: = NEW SPRINKLER PIPE (UNO) = NEW 48" FLEX DROP (UNO) SPRINKLER HEAD LEGEND: = EXISTING PENDENT SPRINKLER HEAD = ADD PENDENT SPRINKLER HEAD EJOR` GLU-LAM OR BEAM •aua"Twnnnnr.� Ifiredid MODEL #SWG 20 ALL THREAD ROD HANGER RING SAMMY SIDEWINDER HANGER TYPE SW NTS 48" FLEX DROP mom 111 111 1/2" SSP \-1/2" SSP 1" ARM -OVER (VARIES) FLEX DROP NTS H J • • h� j Y { .. . _ AREA OF L ; �' w .. "' WORK 9 e• YF F � }..r` Y �+ ::"te �vJ tl f> r. yy'� ii 9 -_a. s2h G E Fsc$�" it i? a2. 11, �v&a -4?.1)'19[ - ._,.� 51 . , ---. `a3 753 ..:"_ FIRE SPRINKLER PLAN SCOPE OF WORK: 1. ADD (1) NEW SPRINKLERS AS REQUIRED FOR NEW RESTROOM. 2. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 (LIGHT HAZARD). 3. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF (AHJ). 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13 AND THE CITY OF (AHJ). GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET #13. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 9. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. CONSTRUCTION NOTES: 1. ALL NEW PIPE TO BE BLACK, IMPORT SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. SPRINKLER HEADS IN ACT TYPE CEILINGS TO BE INSTALLED ON 1" XV; X 48" FLEXHEADS. 3. SPRINKLER HEADS ARE NOT REQUIRED TO BE LOCATED IN THE CENTER OF THE CEILING TILES. 4. ARMOVERS LONGER THAN 2'-0" SHALL HAVE A HANGER. 5. TYPICAL HANGER TO BE SAMMY SUPERSCREW MODEL GST -20 (UNLESS NOTED OTHERWISE). s D V . -:.. ,: Comments g �t in R i 1= v ► t i „3C' Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance current City Aundards. Acceptance is subject to €.rrors and omissions which do not authorize violations of adopted standards and .- rdinance . The responsibility for the adequacy of design rests totally w.~ the designer. Additions, deletions or revision:; to these ,Drawings after this date will void this acceptance, and wig require a resubmittal of revised drawings for sufosequent approval. Final acceptance is subject to field test and -Inspection by The Tukwila Fire Prevention Bureau. Date: - 6- ! • By: SCALE: 1/4" =1'-0" TUKWILA FRE r''Z.-A .ITi`.:7 Please call 206-575-.1407 a td give this Fire Permit No. ii -S- and exact address for shut- down or restoration approval. • REVISIONS HYDRAULIC DESIGN INFO. HANGER LEGEND SPRINKLER HEAD LEGEND - • ALARM VALVE RISER - • FLOW SWTICH RISER • - DRY PIPE RISER O - DELUGE/P.A. RISER - FIRE DEPARTMENT CONNECTION .gam - WATER MOTOR GONG - ELECTRIC BELL -FLEXIBLE GROOVED COUPLING —El-- - RIGID GROOVED COUPLING —0- - THREADED PIPE COUPLING - CONTROL VALVE ->-- - CHECK VALVE - PIPE HANGER (SEE CHART) - SEISMIC BRACE (SEE CHART) 1 9-0 1 (8-10) - WELDED PIPE TAG - BRANCHLINE NUMBER PIPE SIZE & LENGTH - PIPE SIZE & LENGTH (CUT) - HYDRAULIC NODE * 10'-10" FF - ELEVATION DATUM * 0'-10" TS - CENTERLINE OF PIPE TO DECK MK DATE BY DESCRIPTION nTHIS SYSTEM I5 HYDRAULICALLY DESIGN® THIS SYSTEM I5 NOT HYDRAULICALLY DESIGNED A U -HOOK L "L" ROD SPRINKLER TYPE/ SIN NUMBER MFG MODEL SYMBOL K -FAC THREAD TEMP FINISH CANOPY QTY - FLOW TEST - STATIC: RESIDUAL: GPM FLOWING: DATE & TIME: - SYSTEM DESIGN - REMOTE AREA: DENSITY: MAX AREA/HEAD K -FACTOR B COACH SCREW ROD N TOGGLE NUT ADD RECESSED PENDENT HEAD / TY3231 TYCO TY -FRB OA 5.6 1/2" 155° CHROME CHR/REC 1 C "C" CLAMP P HDI -P D TOP BEAM CLAMP W/ STRAP R WEDGE ANCHOR E EYE ROD S SAMMY SUPER SCREW (GST20) F FLUSH SHELL SW SAMMY SIDEWINDER (SWG20) G CEILING FLANGE SX SAMMY X -PRESS H SIDE BEAM BRACKET T TRAPEZE J "J" BOLT U UNISTRUT POST K SHORT CLIP CP CPVC TYPE HANGER TOTAL THIS SHEET 1 Fire Sprinklers WA CL# FJRESI*988F.J 1524 45th St E - Suite 102 Sumner, WA 98390 (253) 826-0099 PROJECT: 730 Andover Park East 730 Andover Park East Tukwila, WA CONTRACT WITH: Phill Hunter • PAID SEP 29 2011 UKWILAFIR ./t/7c/e0 DESIGNER: Travis Kinne DATE: September 28, 2011 SCALE: As Noted • HAZARD: As Noted AHJ: City of Tukwila JOB # 2905 SHEET# FP1 OF 1 CITY OF TUKWILA FIRE DEPARTMENT /111 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION King Co. Assessor's Tax No.: 2623049095 Site Address: 730 Andover Park East Suite Number: 730 Floor: 1 Tenant Name: New Tenant? ❑ - Yes ® - No Property Owner's Name: 790 ANDOVER LLC Mailing Address: P.O. BOX 287 Medina WA 98039 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Travis Kinne Company Name: Fire Sprinklers Inc. Day Telephone: 253-826-0099 Mailing Address: 1524 45th Street East, Suite 102 E-mail Address: Travis Kinne Sumner City WA 98390 State Zip Fax Number: 253-826-1033 Valuation of Project (contractor's bid price): S 1,139 Scope of Work (please provide detailed information): Add (1) Head in new bathroom. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORHORIZED AGENT: Signatur - Print Name: Travis Kinne Date: 9-28-11 Day Telephone: 253-826-0099 Plan Permit App.doc 5/14/10 TFD FP Form 8