HomeMy WebLinkAboutPP - 790 ANDOVER PARK EAST - UNKNOWN - PERMITS AND PLANS790 ANDOVER PARK EAST ASSOCIATED PERMITS 19-F-084 19-S-067 TRAINING 1 121 I PRIVATE PRIVATE PRIVATE QeFICF 1 105 1 PRIVATE OFFICE 1 104 j--• FIRE ALARM LEGEND QTY SYMBOL DESCRIPTION MANUFACTURER MODEL # Fire Alarm Control Panel Silent Knight SK 5820XL—EVS = Addressable Relay Module Silent Knight 4101SN LY Remote Anunciator Silent Knight 5860R 50 WATT AMP Silent Knight ,EVS-50W Ft" -4 Y''"'-1 MH Mag Door Holder GE )HR2420C 1 ® Smoke Detector Silent Knight SD5056APS CRF Wireless Smoke Detector Silent Knight 6806 O Heat Detector Silent Knight SD5056AHS 11 IJ Horn Strobe Ceiling MountSystem Sensor PC2R 5 ® Strobe Ceiling Mount System Sensor 32/PC2 ®4 Speaker/Strobe Wall System Sensor ,SPSRV ® Strobe Wall Mount System Sensor SR © Pull Station Silent Knight SD500PS 0 Addressable Input Module Silent Knight SD500MIM © Sprinkler Water Flow Provided By others T Sprinkler Tamper Provided By others E Post Indicating Valve Provided By others Duct Detector Provided By others B) Out Side 10' Bell System Sensor SSM24-10 1 l REMOTE POWER SUPPLY Silent Knight 5496 NOTES: DEDICATED t2D AC 201412. CIRCUIT NEMER t2EAMX MIRED ._ ICH IACICCUE. IAl AT PAM AC PMC. R MER MC CROAT RARER LOCATE IN TRAINING ROOMl121 CEILING/DECK MAX 30'-0" (360') U CEILING MOUNTED SEE NOTE 4 0 CEILING MOUNTED l�J SEE NOTE 5 CEILING MOUNTED O=ILING MOUNTED SEE NOTE 3 SEE NOTE 3 SUSPENDED CEILING (80') 4_J SEE NOTE 1 MAX 6'-0" (72") & MIN 5'-6' (66") 1 RPS FACP 2 NOTE SEE MAX 4'-0" (48') MIN 3'-6" (42") FINISHED FLOOR 1. COORDINATE EXACT MOUNTING HEIGHT OF POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 2. MEASURED TO THE OPERABLE PART OF THE PULL STATION. 3. WHERE INDICATED ON THE DRAWINGS - LOCATE CEILING MOUNTED NOTIFICATION APPLIANCES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, SPRINKLERS, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. 4. WHERE INDICATED ON THE DRAWINGS - LOCATE CEILING MOUNTED SMOKE DETECTORS ON THE BOTTOM OF THE DECK/SUSPENDED CEILING (NOT ON BOTTOM OF STRUCTURAL MEMBERS), AND AS INDICATED IN NFPA 72, 5. WHERE INDICATED ON THE DRAWINGS - LOCATE CEILING MOUNTED NOTIFICATION APPLIANCES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. CONDUIT NOTES: 1. ALL OPEN FIRE ALARM CABLING SHALL BE CONCEALED FROM PUBLIC VIEW. 2. FiRE ALARM CABLE SHALL NOT BE PAINTED. FIRE ALARM CABLING OPEN FIRE ALARM CABLING DETAIL Scale 3/32" = 1 SOURCE: Ver. 2013.A 05 NOT TO SCALE RAS SLC 14/2 FPLR OUTPUT 1 14/2 FPLR OUTPUT 1 14/2 FPLR OUTPUT 1 14/2 FPLR Without Comments As Noted ;n Red 0 Per The r tta ct.ed Letter nese plans have been reviewed by .ire Tukwila Fire c 'ention Bureau for corlforrrier, _ i^:: i': current City •idards. Acceptance is subjecr to e -ors nd ossions which do nOc autnorize .'olations of adopted ndards and Ordinances, me resDons:r4iity for the 'guacy of desir: ; 5$ totally with a designer. • ditions, deletion c :cvi5i0n5 to thie• :- drawings afte :bis date will void tri .. c ptdrice and w) require a resubmittai of reviser" r:i-awings for subsequent approv . sinal acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: 571)-- ! `1 By: E Please call 706-5, ti 's.:, Y and give tills Jnd exact address for;,hut- down or restoration 6pprovZ!. CONtROLUNIT ANMPICWTION SCOPE OF WORK INSTALL FIRE ALARM DEVICES AS SHOWN ON DRAWING NO13 CA1 ON MSC PILI I STATION WATFRFI OW SPRINKI FR VAI VF TAMPFR PAINT rlflnTlI VAI VI TAMIYR FACP IQWRATTFRY FACP AC FAII IIRF HVAC DUCT DFTFCTOR OPFN GIRCIUT GRrltINrl FAIII T WIRF TO WIRF SHORT PHONF IMF I OSS FIRE ALARM SEQUENCE OF OPERATION Fire Alarm General Notes Wiring routes are for reference only. Device circuits have been engineered and calculated for current draw and voltage drop. Panel, annunciator, and power supply locations shall be mounted in locations shown. Any deviation of circuitry from those shown shall be reviewed and shown corrections if any on as -built drawings. All 120 VAC power requirements for the fire alarm shall be furnished and installed by the electrical contractor. The installation shall meet the requirements of the AHJ and local codes. All conduit sizing and ratting by electrical contractor per NEC 70 and local codes. Field verify all s prinklerwater flow, tramper valve, and PIV switch locations. Field verifies any HVAC fan shutdown requirements and duct detector locations per NFPA 72. Addressable devises) shall not be located near high electrical or magnetic field generating devices such as transformers, HID lighting ect_ regardless of location shown on drawing. Per MPS 72 sections 2-3.6.1.3 smoke detectors shall not be installed until after the construction cleanup of all trades is complete and final. Equipment listed on legend shall be supplied by Meridian Security Inc. Equipment listed as supplied by others shall be furnished and installed by the corresponding trade. •t= USE RED AID BLACK CONDUCTORS FOR SLCLow 12curr wear BUR AHDBROWHCONDECIORBAU. THE WAY THRUTHE CRCUiFOR FUTURE USE NOTES: 1. FOR CEILING MOUNTED SMOKE DETECTORS AND OCCUPANT NOTIFICATION APPLIANCES IN AREAS WITH SUSPENDED CEILINGS. JUNCTION BOX MOUNTING DETAIL PMD APR 1 6 2019 TUKWW1!L;i F!PF . .f459 '3/ - REVISION DATE 4/10/2019 DRAWN BY SCOTT HARRIS All designs/plans listed are the sole properity of Meridian Security and are for use by Meridian Security only, unless otherwise noted. We reserve the right to make changes or corrections. STEVEN M DELIMONT NICET III ID #132990, WA STATE JOURNEYMAN# DELIMSM98ORG FA 01 bra /'P€. D Without Comments p As Noted in Red g Per The Attached Letter These plans have been reviewed by The Tukwila Fire PrevenglOn Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordI ances. The responsibility for the adequacy of des!!,' ;sj, totally with d designer. Additions, deletict ;;' '. ' 'evasions to these drawings after this date will vo c1 telt .'ceptance and will require a resubmititi OFr: �, �� diT3wings for subsequent approval. Final acceptance is sub .ct to field test and Inspection by The Tukwila Fire Prevention Bureau. Date: 9 By: \ I N.I.C. WAREHOUSE 125 o.T.s. 23'-0 TUKWILA KM DPS Plea call 206-575-4407 and givethis Fore Permit ape s _ and exert address -Tim p4F dawn or restorotion PpLV I ? 0 O.T.S. 23'-0' 0 N WAREHOUSE 126 N EX. 6' MAIN 0 LL L N 0 TRAINING ROOM 121 O.T.S. 23'-0- - N.I.C. oy 2- " -Ks. - -CONFERENCE-106----- PRIVATE OFFICE 105 - PRIVATE OFFICE 104 PRIVATE OFFICE 109 ss 1" 2'-5" STORAGE CLOSET • TECH -1R1.- CLOSET O� , ;119--x 4 zp rn BREAK! ROOMI 1161 --IN I PRIVATE - +e 0-FICE 110 OOFFICE 111 tro M O .rtr, '►1 010'` ,�' ►.� 0'-10' o i ,1 ['i3 1 2 .k.* 1} i,4, .�. ACT -1 94* a OPEN OFFICE -101 5'-e' MENS 114 2 '-ENTRY - 100 J I' DN1'X0'-2' PER PLAN ALL DROPS 13'-0' TYP. 0 N 0 T.I. FIRE SPRINKLER PLAN SCALE: 1/8" =1-0" -10 0 10 20 40 SCALE: 1/8" = 1'-0" SAMMY SUPERSCREW ■r - TYPICAL FLEX DROP MOUNTING DETAIL WASHONOTON STAT COR rW'ICATO OF COOPOTONCY 1"tRg PROTOC?1OM Theodore M. Queen 4930-0205-C Level 3 Archer Construction, Inc. ARCIAE 219DR MECHANICAL TEE DROP LENGTH 13'-0" TYP I I r4 SSP 1" ARM -OVER (VARIES) FLEX DROP PER PLAN 48" (U.N.0) TYPICAL DROP DETAIL SPRINKLER LEGEND: 2 8-6 2 = NEW PIPE = EXISTING PIPE -f- = HANGER MT = MECHANICAL TEE = EXISTING UPRIGHT HEAD LOCATION Q = NEW UPRIGHT HEAD LOCATION (TOTAL OF 5) = NEW HEAD LOCATION (TOTAL OF 37) SCOPE OF WORK: 1. MODIFY EXISTING OVERHEAD FIRE SPRINKLER SYSTEM TO ACCOMMODATE NEW TENANT WALLS & CEILING. CLARIFICATIONS: 1. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED AT A MINIMUM OF 40°F (BY OTHERS) IN ORDER TO PREVENT THE PIPE FROM FREEZING. EXCLUSIONS: 1. RELOCATION OF EXISTING MAIN AND BRANCH LINE PIPING. 2. HYDRAULIC CALCULATIONS - 3. INSTALLATION OF SPECIALTY SYSTEMS: DRY SYSTEM, KITCHEN HOOD, EXHAUST DUCT. 4. CHANGE OUT OF EXISTING HEADS TO QUICK RESPONSE. 5. CUTTING, PATCHING, AND PAINTING OF STRUCTURE. 6. PAINTING, PREPARATION OR CLEANING OR PIPE. 7. SHUTDOWN FEES, WSST, BONDS 8. ANY AND ALL ELECTRICAL OR ALARM WORK. 9. DEMOLITION OF EXISTING BRANCH LINE. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA #13. 3. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13. 4. PIPING SHALL BE IN ACCORDANCE WITH NFPA #13. 5. ALL ARMOVERS GREATER THAN 1' SHALL HUNG PER NFPA #13 SECTION 9.2.3.5.2.1 DESIGN CRITERIA: 1. DESIGN AND TESTING BASED ON NFPA 13 (2013) AND TUKWILA CODES. 2. EXISTING WAREHOUSE CRITERIA - STORAGE. 3. NEW OFFICE CRITERIA - ORDINARY HAZARD GROUP 1( PER TUKWILA) 4. NEW USE AND DESIGN CRITERIA ARE EQUAL OR LESS THAN THAT OF THE EXISTING, THUS NEW HYDRAULIC CALCULATIONS ARE NOT PROVIDED. FITTER NOTES: 1. PARCEL # = 262304-9095 - -2 NER;_LBA RVI -COMPANY XVI LLC, 334.7 MICHAELSON DR #200, IRVINE CA 92612 3. OCCUPANCY: B (BUSINESS), S-2 (STORAGE) 4. CONSTRUCTION TYPE: III -B Parirvay Square Shipping Center I Macy's Logistics and Operations DATE REVISIONS DESCRIPTION BY A B HANGERS BEAM CLAMP W/ RETAINING STRAP HYDRAULIC DESIGN INFORMATION ABBREVIATIONS SITE / KEY PLAN SCALE: NTS El) VICINITY MAP SCALE: NTS \ 0 HOR C0\ST PAID MAR 2 ) 2019 TUKWILA FIRE H112.:(7 - WATERFLOW INFORMATION SPRINKLER SYIVIBOI SIDE BEAM BRACKET G EYE SOCKET AREA NUMBER CODE HAZARD SYSTEM TYPE D NUT & PLATE WASHER E KWIK-BOLT REMOTE AREA SQ. FT. DENSITY GPM/SQ. FT. - INSIDE HOSE ALLOWANCE - OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER F HDI -P G SAMMY SIDEWINDER H SAMMY SUPERSCREW TOTAL SYSTEM REQUIREMENTS: J COACH SCREW ROD K CEILING FLANGE HYDRAULIC DESIGN INFORMATION L U -HOOK M N SHORT STRAP AREA NUMBER - CODE HAZARD SYSTEM TYPE WALL BRACKET P TRAPEZE Q REMOTE AREA SQ FT. DENSITY GPM/SQ. FT. - INSIDE HOSE ALLOWANCE - OUTSIDE HOSE ALLOWANCE AREA PER SPRINKLER TOTAL SYSTEM REQUIREMENTS: AFF BOB BOD BOJ BOP BOT CTS FO IFOW OFOW NAS UNO ABOVE FINISHED FLOOR BOTTOM OF BEAM BOTTOM OF DECK BOTTOM OF JOIST BOTTOM OF PURLIN BOTTOM OF TRUSS CUT TO SUIT FIELD ORDER INSIDE FACE OF WALL OUTSIDE FACE OF WALL NO AUTO. SPRINKLERS UNLESS NOTED OTHERWISE RIGID COUPLING FLEXIBLE COUPLING STATIC XX PSI SYM MAKE MODEL SIN# TYPE RESIDUAL XX PSI GPM FLOWING XXXX GPM DATE & TIME PER: XX/XX/XXXX 0 VICTAULIC V27 V2704 0 VICTAULIC V27 V2708 UPRIGHT RECESSED PENDENT FINISH BRASS CHROME K -FAC. THR D ORIFICE TEMP CANOPY QTY K=5.6 yz . 155° 5 K=5.6 155° CHROME 37 LOCATION: NOTES: TOTAL SPRINKLERS THIS SHEET 42 ARCHER CONSTRUCTION, INC FIRE SPRINKLER DIVISION 7855 S 206TH STREET, KENT, WA 98032 PHONE 253-872-7222 FAX 253-872-7277 PSAV ANDOVER PARK EAST TI 790 ANDOVER PARK EAST TUKWILA, WA 98188 FIRE SPRINKLER PIPING PLAN PERMIT NO: - JOB NO: S19=034 AUTHORITY: CITY OF TUKWILA CONTRACTOR: MICHAEL KING / OLIN WICK PHONE: 425-746-1000 DESIGNER: KN SCALE: NOTED DATE: 3/22/2019 REVISED / / PLOTTED / / FP 1 OF 1 790 ANDOVER PARK EAST ASSOCIATED PERMITS D12-019 INSPECTION NUMBER INSPECTION RECORD Retain a copy with per 't PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:Typ � o ',5 /-n -t� -6 of Inspection: i<4/1-eK Address: -7 q 0 Suite #: iptp Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. / X Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Forc,k-S o fr 11/4i epi £ l r� s s A 1 k it✓g 4 1 --es 4- A'lorti A) k ,�X , -/-- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: t l cam-- Date: 3/0WJ Z Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit QO /�..0,Is PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: It/tOeS Tv tit .511 i it5 5 - Typ pection: Address: Address: 79 o Suite #: A -P Conta Person: ( ,c(1,q. Special Instructions: Phone No.: nApproved per applicable codes. Corrections required prior to approval. COMMENTS: OU 2,ed S e.(f re SS /i c tri.( IVJ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:S _ Date: 7// 7/1? Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e ity of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: ga Rac-k A Company Name: N1ve.'s /+j,'- er , Address: 7/0 AN Doves' PI( > City: —r-c,f, 1A State: (J Zip: TY/ Ili' Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS RT ocOss CITY OF TUKWILA FIRE DEPARTMENT koz.+ 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 't30/19 ----- INSPECTION NUMBER Project: c 5 Altit 51-1 r Fire Alarm: Typ of Inspection: Monitor: Address: -29 U Suite #: i") J Conta Person: 4 Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: etre SS /i c�iit d '? "%eg. el Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Infector: ii ;--- Date: 7/1 7 7,1-? Hrs.: INSPECTION FEE REQUIRED. You will receive an invoice from la Finance Department. CaII to schedule a reinspection. (Billing Address Attn: l�� �.vc--k AMr�e '�j S n-� r N�sk iYs' Address: 710 PrrJ Dooms/' Ply E Company Name: State: /- Zip: City: 'e c. kms, I s9 Word ecord Form.Doc 6/11/10 T.F.D. For INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit So c►. D/2-61? PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: mpGs ,,4/ �T� Type of Inspection: Hrs.: Address: -77o -- 790 Suite #: opE Contact Person: gar Special Instructions: / Phone No.: 02vG ZG/ .6x1 7 Approved per applicable codes. riCorrections required prior to approval. COMMENTS: ,,4/ �T� Sprinklers:/ Hrs.: i JL ,44..4- n ice. Pi es, )..ly 1oa14z.01_ .-o -PI a 4$4....• r3,)1 Ut. t?"40)e 4.6 b.. fcr a ....i- o 79 '4i Monitor: / Pre -Fire: "neer_ 16 /.- OLiiTa rG y..- if eri i i t '{'GKN £.•ir1LS eve - 7 ?v , E Needs Shift Inspection: ,,4/ �T� Sprinklers:/ Hrs.: Fire Alarm: Hood & Duct: Monitor: / Pre -Fire: Permits: Occupancy Type: Inspector: ,,4/ �T� Date: $J j? ht._ Hrs.: J .0- $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he Cityof Tukwila Finance Department. Call to schedule a reinspection. p P Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113