HomeMy WebLinkAboutPP - 14410 41ST AVE S - UNKNOWN - PERMITS AND PLANS1441041STAVE S ASSOCIATED PERMITS D14-0073 D14-0070 D14-0072 D14-0069 D14-0071 D14-0068 i INSPECTION RECORD Retain a copy with permit �` ro INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project. gIvr-lw're,croze /tr+S• Type of Inspection: JCS 1!Z/S j �%rA�? Address:!ala Suite #: ryy + 3g /(00/7, Contact Person: ,ii\ -'fon Pre -Fire: Special Instructions: l / 4f%lY', "146 , / qt -82/ L% S Phone No.: /eS ic Approved per applicable codes. Corrections required prior to approval. COMMENTS: n 3iJL\ A tI ' 'tf '" d0 (Q �l - 1i2- ay.. Om Rbc,c- 4 I I6u()Af rM /^'sal( iviow /A/$&'/fir-t 4 6,( , /2F / BiLfoi 3 bi q - ob12, — 5 k, Monitor: Pre -Fire: Lt1CLI '4\)N- 00-73 — c Occupancy Type: 1E • b Dl' - 0 8 -- SQL. L_ pig- 0011 - .S .e. -3�.(dl-.) i 1-O b -) o - S Avwe' - ildia en‘siwilfr' 'i 71 aAtCA Fafai;7 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:— , ,Jfg3 Date: Zft4// — Hrs.: 2 . 5-- / / / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Ili -M MLA ENGINEERS, - iNC. TACOMA SEATTLE OLYMPIA TACOMA OFFICE 6L 12th Street East, Suite 200 `racoma, Washington 98424 Phone (253) 922-0446 Fax (253) 922-0896 FLOW TEST RESULTS Fl PROJECT NAME: King County Housing Authority - Riverton Terrace LE PROJECT LOCATION: 14410 41st Avenue South Tukwila, Wa.98168 DATE OF FLOW TEST: January 19th, 2007 TIME OF FLOW TEST: 11:00 A.M. TEST CONDUCTED BY: Fred Blanchard of B.C.E. Engineers Joe Synder of B.C.E. Engineers TEST WITNESSED BY: Don Tomaso of the City of Tukwila Fire Department Russ Austin of King County Water District #125 TEST HYDRANT (STATIC/RESIDUAL) LOCATION: The static/resdival test location was a hose bib on the water meter serving an undeveloped lot on the North side of South 144th St. across from 4021 S 144th St. FLOW HYDRANT #1 LOCATION: Flow hydrant #1 is located on the North East corner of the intersection of South 144th Street and 41st Avenue South. FLOW HYDRANT #2 LOCATION: Not Used for this test. lotATtoN • new NYORA'UT 01 Son 144' SMELT 40 21 SOUTH 144" S►ett7 prao7EcT SITE 14410 41sr AVEIJUE SoiSM SKETCH OF WATER DISTRIBUTION SYSTEM HYDRANT FLOW (G.P.M.) = 29.83 x C x D2 x (PITOT PRESSURE)'" FLOW AT 20 P.S.I. TOTAL FLOW x (STATIC (PREssuRE) - 20) (STATIC (PRESSURE) - RESIDUAL (PRESSURE)) TEST HYDRANT ELEVATION: DIAMETER OF FLOW HYDRANT PORT (D): C -VALUE OF DISCHARGE PORT (C): STATIC PRESSURE BEFORE FLOW TEST: STATIC PRESSURE AFTER FLOW TEST: PITOT VALUE (HYDRANT #1 - PORT #1): PITOT VALUE (HYDRANT #1 - PORT #2): PITOT VALUE (HYDRANT #2 - PORT #1): PITOT VALUE (HYDRANT #2 - PORT #2): 238.00 FEET 2.25 INCHES 0.88 90.0 P.S.I. 62.0 P.S.I. 47 P.S.I. 47 P.S.I. P.S.I. P.S.I. HYDRANT #1 - PORT #1: 911.07 GALLONS HYDRANT #1 - PORT #2: 911.07 GALLONS HYDRANT #2 - PORT #1: GALLONS HYDRANT #2 - PORT #2: GALLONS TOTAL FLOW FROM HYDRANTS TESTED: 1,822.13 GALLONS TOTAL FLOW AT 20 P.S.I. RESIDUAL PRESSURE: 2,990.08 GALLONS