PP - 664 INDUSTRY DR - UNKNOWN - PERMITS AND PLANS
664 INDUSTRY DR ASSOCIATED PERMITS 01-F-122 WIRE SCHEDULE AND CONDUIT FILL CHART WIRE DESIGNATION SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE F INITIATING CIRCUIT TWO #18 FPL/THHN RED (JACKET) S SIGNALING CIRCUIT - AUDIO TWISTED PAIR W/ SHIELD #14 FPL RED/BLACK CONDUIT FILL CHART NO. OF CONDUCTORS VOLTS WIRE SIZE TYPE TWO 600V #12 AWG THHN/THWN TWO 600V #14 AWG THHN/THWN TWISTED TWO CONDUCTOR 300V #18 AWG FPL TW CABLE CONDUIT FILL CALCULATE THE TOTAL AREA OF THE WIRE BEING RUN IN THE ABOVE. CHOOSE THE SIZE OF CONDUIT BASED ON THE MAXIMUM THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAL AREA OF CONDUIT SIZE MAXIMUM F 1/2" .12 SQUARE 3/4" .21 SQUARE 1" .34 SQUARE 1-1/4" .60 SQUARE 1-1/2" .82 SQUARE 2" 1.34 SQUARE FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE TAKEN FROM DIMENSIONS AREA .244 0.D. .0467 .210 0.D. .0346 .156 0.D. .0191 CONDUIT FROM THE TABLE FILL DIMENSION FROM THE WIRE. LL NCH NCH NCH NCH NCH INCH N.E.C., CHP. 9, TABLE 4. WIRE DESIGNATION 1. ALL WALL -MOUNTED AUDIBLE & VISUAL SIGNALING APPLIANCES SHALL HAVE THEIR HEIGHTS ABOVE THE FINISHED FLOOR AT 80" TO BOTTOM. NEPA 72, 1999 EDITION, ALLOWS 80"-96" FOR VISUAL DEVICES (CH. 4-4.4) AND REQUIRES A MINIMUM OF 90' TO TOP FOR AUDIBLE DEVICES OR 6" FROM CEILING, WHICHEVER IS LOWER (CH. 4-3.5). FOR SLEEPING AREAS GREATER THAN 16' (LINEAR) VISIBLE N❑TIFICATI❑N SHALL BE WITHIN 16' OF PILLOW AND GREATER THAN OR EQUAL TO 24' FROM CEILING TO TOP OF LENS FOR 110cd (CH. 4-4.4.3.2) 2, ALL EQUIPMENT SHALL BE U.L. LISTED. 3. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHO❑TING, ETC. 4, D❑ NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER (GUARDIAN SECURITY SYSTEMS, INC., TEL (206)622-6545). FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 5. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR -FLOW, NOR CLOSER THAN 3 FEET (900r1n) FROM AN AIR SUPPLY DIFFUSER. 6. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES, AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL CONTRACTOR. 7. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACT❑R, 8. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION. 9, ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTI❑N BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITI❑NAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE N❑TED, 10. SMOKE DETECTOR TESTING SHALL BE ACCOMPLISHED WITH TEST MAGNETS AS PER THE MANUFACTURER'S INSTRUCTIONS. 11. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL P❑INT OF ANNUNCIATI❑N. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS. 12. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES. ALL SPLICED WIRE P❑SSESING SHIELDS SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. 13. P❑INT AND COMMON ANNUNCIATION AND T -TAPPING (EXCEPT SLC LOOP) ARE PROHIBITED. 14. PR❑VIDE 3/4' CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATION MONITORING. 15, THE ALARM SYSTEM SHALL HAVE AN AUDIBILITY OF NOT LESS THAN 15dB ABOVE AMBIENT N❑ISE LEVELS. TESTING SHALL BE ACCOMPLISHED WITH A dB METER. 16. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH N❑N-ELECTR❑NIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL 'WED SERIES' ONLY. 17. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 18. FIRE ALARM SYSTEM INSTALLATI❑N COMPANY SHALL BE UL LISTED (UUJS). 19. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH NEPA, LOCAL AND STATE, NEC AND CONTRACT DRAWINGS 20. ALL CONDUIT SIZING AND ROUTING BY ELECTRICAL CONTRACTOR PER NEC AND AHJ 21. THE FACP SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF G.S.S. TECHNICIANS 22. A SET OF INSTALLATI❑N AS -BUILT DRAWINGS SHOWING ACTUAL CONDUIT AND CONDUCTOR ROUTES SHALL BE KEPT BY PROJECT FOREMAN FOR USE BY G.S.S. FIELD TECHNICIANS 12/24 BLDG. ELECT OPEN ROOM 7 OFFICE ROOM 8 EX OFF ICE R❑❑ v1 9 n EX OFFICE ROOM 10 HEX go OPEN ROOM 13 OPEN ROOM 5 4-44 konVs ROOM 11 ElEX ROOM 1 H BATTERY SIZING CALCULATION )1( * A AANEWWWWWWWWWWWWWAAWWWWWWWWWWWWWWWWWWWWWAWAWAAWWWWWWAXWWWWWWWWW Job Name: HALLW❑❑D BUILDING 12 Panel Location: POWER SUPPLY BATTERY CALC Date Performed 06-01-2001 QTY. DEVICE NAME STD-BY(Amps) ALARM(Amps) 1 FCPS: FCPS-24 7 SMOKES 2451 1 H/Ss AS -24110W 1 H/Sr AS -2430W 2 STR1 RSS(15CD) 0. 0480 0. 0008 0. 0000 0. 0000 0. 0000 0. 0480 0. 0700 0. 1770 0. 0980 0. 1060 Stand -By Load = Stand -By Time = Totals = 0. 0488 0. 4990 0.0488 Amps Alarm Load = 0.4990 Amps 24 Hrs. Alarm Time = 5/60 Hrs. Stand -By = 1.17 Amp*Hrs Total = Stand -By + Alarm = 1. 17 + 0.04 = 1.21 Amp*Hrs Alarm = 0.04 Amp*Hrs Multiply by De -Rating Factor of 1. 25 ---> 1. 21 * 1.25 = 1. 52 WWWWWWWWWWWWWWWWWWWAAWWWWWAAWAAAAWAWAWAAWAWAWAW ) * MINIMUM BATTERY SIZE = 1.52 Ampere*Hours AWAXWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WORST CASE VOLTAGE DROP CALCULATION )1( WWWWWAWAWANOKAAWAWAAAWAXAWAWWWWWWAWAXWAAWWWWWWWWWWAAWAAAWWWWWWW Job Name: Circuit Date Performed: 1 H/S: 1 H/S: 2 SIR: HALLW❑❑D_ BUILDING 12 POWER SUPPLY VOLTAGE DROP 06-01-2001 AS -24110W at 0.1770 Amps each AS -2430W at 0.0980 Amps each RSS(15CD) at 0. 0530 Amps each = 0. 1770 Amps 0. 0980 Amps = 0. 1060 Amps Circuit Length = Circuit Load = Voltage Drop = Total = 0.3810 Amps 110 Ft to End Wire Size = #14 AWG 0. 3810 Amps Voltage = 24.0 Volts (Ckt. Load) * (Ckt. Length) ) 21. 6 )1( 100% <Circular Mils) ) (Volts) ( 0. 3810) * ( 110 ) ) 21. 6 Voltage Drop = * 100% ( 4110 ) * ( 24. 0) Voltage Drop = 0.92% AAAAWAWAAAAAWANEAWAWAAAAWAAA )1( VOLTAGE DROP = 0.92% 3* )1( AAAAAAWWWWWWWWWWWWWWWAWAXWA QUANTITY 7 4 2 SYMBOL DESCRIPTION MODEL ` MANUFACTURER BACKBOX MOUNTING HEIGHT 12/24 REMOTE POWER SUPPLY PS -12/24-8 NOTIFIER PROVIDED 66" AFF TO TOP © CONVENTIONAL 2451 PHOTOELECTRIC DETECTOR NOTIFIER 4S DEEP BOX W/ CEILING 3-0 RING CONVENTIONAL EXISTING ©CONVENTIONAL PHOTOELECTRIC DETECTOR N/A 4S DEEP BOX W/ CEILING 3-0 RING F_TEX (ABOVE CEILING) HEAT EXISTING N/A 4S DEEP BOX W/ ABOVE CEILING 3-0 RING 1® FIRE ALARM STROBE (15CD) RSS-2415 NOTIFIER 4S DEEP BOX 80" A.F.F. NO RING TO BOTTOM 30 FIRE ALARM HORN/STROBE AS -2430W WHEELOCK 4S DEEP BOX NO RING 80" A.F.F. TO BOTTOM FIRE ALARM AS -24110W WHEELOCK 4S DEEP BOX HORN/STROBE NO RING 80" A.F.F. TO BOTTOM ❑J FIRE ALARM N/A BY ELECTRICIAN 4S BOX JUNCTION BOX U.O.N. VERIFY IN FIELD FATC FIRE ALARM TERMINAL CABINET N/A BY ELECTRICIAN 18 x 18 x 6 U.O.N. VERIFY IN FIELD A.F.F. ABOVE FINISHED FLOOR N/A N/A N/A N/A C ABOVE CEILING N/A N/A N/A N/A EOL END OF LINE N/A RESISTOR N/A N/A N/A EX EXISTING DEVICE N/A N/A N/A N/A F.B.O. FURNISHED BY N/A OTHERS N/A N/A N/A N/A NOT N/A APPLICABLE N/A N/A N/A U,O.N. UNLESS OTHERWISE NOTED N/A N/A N/A N/A VL VERIFY LOCATION IN FIELD N/A N/A N/A N/A WP WEATHERPROOF DEVICE N/A N/A N/A N/A SYMBOLS BOLS LEG 628-4990 x L +) FROM CONTROL PANEL (-) �+) FROM FCPS �-) SMOKE/HEAT OETECTORS E❑LR EOLR WIRING DIAGRAMS �G TUKWILA FIRE DEPARTMENT Please calf: 575-4407 and give this job No. d/- T and exact address for shut' down or restoration approval[. JUNCTION BOX MOUNTED ON CEILING SLAB PREVI❑US DEVICE 0 0 0 0 HEAT DETECTOR JUNCTI❑N BOX MOUNTED AGAINST CEILING SUPPORT SMOKE/HEAT DETECTOR ACCEP Ej Without Cor'nrrr,n1s As Noted In Rett Per The Attached Letter 0 These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city • this data wil! void this ac cepanc Acceptance is subject to errors and omissions which do not authorize violations of adopted standards ar��d ordinenc.�•:-;. TNreg>por,si lity for the adequacy of design r +i: 1:o:� ii, wife, !:re designer. Additions, deletions dr :;.: iso��n:i *; ';.i:*c.e : I v Ings after and will require a I'standards. 6 resubmittal or revised drawings ttorsubsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: -5--- 50^ ° I By: % I TO NEXT DEVICE SUSPENDED ILLUMINATED CEILING IIOIGE/HEAT MOUNTING DIAGRAM 4S DEEP BOX W/ 4S EXTENSION BOX 4" SQUARE DEEP BACK BOX WITH 1G TRIM RING HEIGHT REQUIREMENTS PULL STATION - STROBE WALL MOUNTED DEVICE MOUNTING ELEVATION N z O W m w V DESCRIPTION FIRE DEPARTMENT REVISIONS W F - 'Q s M z PROPERTIES BLDG 0 0 J J W 664 INDUSTRY DRIVE, TUKWILA, WA 9 1 - W W 1� SCALE: FIRE ALARM SYSTEM 1/8" = 1' -\ DRAWN BY: CEC DESIGNED BY: FRANK CLOSE DATE: 05/22/01 SYSTEM CALCULATIONS MOUNTING DIAGRAMS Copyright 2001 by Guardian Security Systems, Inc. All Rights Reserved \JOB NUMBER: 52780 /" SHEET GENERAL NOTESFA- 01 664 INDUSTRY DR ASSOCIATED PERMITS D08-251 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit MAY 30 2008 OD2- 15/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Lccif 6. 14-e,_, Date: _QZ 9k Type of Inspection: Address: 66 L/ 2-4°44 Suite #: 5441 '°. Contact Person: 6 c -FF Ake._ Special Instructions: Monitor: Phone No.: a Do. 57.x' foZZZ V Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Date: _QZ 9k Sprinklers:/ Fire Alarm: / Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: SGJ s) c Date: _QZ 9k Hrs.: J g$80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from he City of Tukwila Finance Department. CaII to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113