Loading...
HomeMy WebLinkAboutPP - 1091 ANDOVER PARK EAST - RYDER SYSTEMS / XEROX - PERMITS AND PLANS1091 ANDOVER PARK EAST ASSOCIATED PERMITS 07-S-275 B95-0068 B95-0112 i INSPECTION NUMBER INSPECTION RECORD Retain a copy witFj.permit MAR 1 1 2008 07-5°' 27 s" PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: it ui d a,Q, etilif. 8ft rbc. Type of Inspection: Address: i 'fl A -AE Suite #: Contact Person: Am, Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Date: d r0 % C. T' U}M% 2_ jiour Monitor: ST♦ghGi" 170-4'G Nso. PJ.r 224 Permits: Occupancy Type: ri cit ?,ir/e. 14 3A" pss- ,224 ' 00 5„,...fek.,,.. A.,s4.I : /1 acid- ..47, hge ve. a.") jga 4,64 - two #w egra- All 4r,i' n /eZtr-1ir.d.5 ylrvnX.1on, A`. F-rfc FN%- i c k Il - )-1, - t ( Needs Shift Inspection: Sprinklers: Date: Fire Alarm:/ Hood & Duct: 2_ jiour Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 3v)6-1 6- Date: 3%S70 x Hrs.: 2_ jiour $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F.D. Form F.P. 113 SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East Tacoma, Washington 98424 CONTR. REG. NO. SMITHFS1360T BUS: (2531 926-1880 FAX: (253) 926-2350 THIS BUILDING IS PROTECTED BY A HYDRAULICALLY AUTOMATIC SPRINKLER SYSTEM DESIGNED PROJECT TITLE BLDG / AREA ADDRESS SFS JOB NO. SYSTEM NO. DESIGN CRITERIA RYDER PALLET STORAGE T.I. INCLUDES TENNANT IMPROVEMENT 1091 ANDOVER PARK E. TI -7175 EXIST / WET NO. OF SPKRS : 84 (NEW) PER NFPA 13-2007 (12) ESFR K25 SPRINKLERS ((4) SPRINKLERS ON (3) BRANCHLINES) FLOWING AT 15 PSI MINIMUM IDLE WOOD PALLETS STORED IN RACKS WITHOUT SOLID SHELVING TO A MAXIMUM OF 25'-0 W/ A 30'-0 ROOF. FILE COPY BASIS OF DESIGN SYSTEM DEMAND 12 HDS DENSITY 1204.95 HOSE ALLOWANCE INCLUDED : VOLUME (IF DRY SYSTEM) WATER SUPPLY : 130 20 GPM / SQ. FT. GPM AT 15 PSI AREA OF OPERATION 50.95 AT BASE OF RISER 0 NA 6723 SQ. FT. PSI GALLONS GALLONS STATIC RESIDUAL FLOWING GPM TEST DATA BY SMITH FIRE SYSTEMS, INC. 1106 54th Avenue East • Tacoma, Washington 98424 (253) 926-1880 • FAX (253) 926-2350 CONTR. REG. NO. SMITHFS1360T HYDRAULIC CALCULATION INFORMATION SHEET PROJECT NAME RYDER PALLET STORAGE T.I. JOB NO. TI7175 1091 ANDOVER PARK E. DATE 03/06/08 ADDRESS TUKWILA, WA 98188 BY JOHN RETHERFORD SYSTEM DESIGNATION: ESFR SYSTEM HAZARD DESCRIPTION: IDLE WOOD PALLET STORAGE TO 25' MAX W/ 30' MAX ROOF HAZARD CLASS PER NFPA 13: 2007 EDITION SPECIFIC RULING: RULING MADE BY: OF DENSITY: (12) SPRINKLER FLOWING AT 15 PSI MIN. (4) SPRINKLERS PER BRANCH LINE ALLOWANCES INCLUDED IN CALCULATIONS: INSIDE HOSE 0 GPM OUTSIDE HOSE 250 GPM IN -RACK SPRINKLER DEMAND SYSTEM TYPE: WET "C" FACTOR OVERHEAD : 120 GPM ADDED AT: NODE 3 (SITE MAIN) TOTAL NUMBER OF SPRINKLERS THIS SYSTEM 84 "C° FACTOR UNDERGROUND : 140 MAXIMUM ACTUAL AREA OF COVERAGE PER SPRINKLER: 96 SPRINKLER MANUFACTURER: VIKING MODEL: VK510 K -FACTOR: K=25.2 SQUARE FEET TEMPERATURE: 165° F ORIFICE SIZE: 1" WATER SUPPLY: STATIC 130 PSI RESIDUAL 20 PSI FLOW 6,723 GPM BASE OF RISER DEMAND(NODE 5) 1204.95 GPM REQUIRED AT 50.95 PSI (INCLUDING 0 GPM FOR HOSE STREAMS) SUMMARY 1454.95 GPM REQUIRED AT 61.69 PSI AT CITY CONNECTION (NODE 0) (INCLUDING 250 GPM FOR TOTAL HOSE STREAMS) w 0 tia. WATER SUPPLY DA ■ - ■ 16 .: ■ +..-- •■' ■■ ■■ L r owl �� :i::■..:...0 ■ ■:. me ..Cu ......C.n........... reign �C'':'. idellikilinillbElliPlimdmilmiliir•N•CCz _. II•l ■ C.■ M :■ :� ■CE;C■■ B..9I �C.�CC i �C ■C : ■.q C C.m::CE .�g.C�C..ppC ui w irk, CCC ' 'C:::' C niC:'CC:':u::C: ■■ ■ .: '°'w a, �■■..■.■:.■i Il■�:■l■t.■■■ ■L ■E n.na. /C.■...■'uii SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 1 TI7175 RYDER PALLET STORAGE T.I. INDOOR STORAGE OF IDLE WOOD PALLETS (12) K25 ESFR SPRINKLERS FLOWING AT 15 PSI MIN. 97.60 GPM FILE = TI7175.SIG FLOW TEST RESULTS Water Supply STATIC 130.00 PSI RESIDUAL 20.00 PSI @ 6723.00 GPM CITY PRESSURE AVAILABLE AT 1454.9 GPM 123.52 PSI SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K -FACTOR PRESSURE 101 105.25 97.60 25.20 17.44 102 100.74 97.60 25.20 15.98 103 98.58 97.60 25.20 15.30 104 97.97 97.60 25.20 15.11 105 1-04195 97760 250 1773 106 100.45 97.60 25.20 15.89 107 98.29 97.60 25.20 15.21 108 97.68 97.60 25.20 15.02 109 104.86 97.60 25.20 17.32 110 100.37 97.60 25.20 15.86 111 98.21 97.60 25.20 15.19 112 97.60 97.60 25.20 15.00 TOTAL WATER REQUIRED FOR SYSTEM OUTFLOWS AT 3 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 21 TO 31 1204.95 GPM 250.00 GPM 1454.95 GPM 61.69 PSI 0.00 PSI 22.11 FPS SUBMITTAL SERIAL NO:2244HY1 TI7175 RYDER PALLET STORAGE T.I. INDOOR STORAGE OF IDLE WOOD PALLETS (12) K25 ESFR SPRINKLERS FLOWING AT 15 PSI MIN. 97.60 GPM FILE = T27175.SIG 03-06-2008 PAGE 2 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 111 112 2.727 L 8.00 C=120 PT 15.00 (112) Q 97.60 F=0 F 0.00 PE 0.00 FM T 8.00 0.0233 PF 0.19 110 111DQ 98.21 2.727 L 8.00 C=120 PT 15.19 (111) Q 195.81 F=0 F 0.00 PE 0.00 FM T 8.00 0.0845 PF 0.68 109 110DQ 100.37 2.727 L 8.00 C=120 PT 15.87 (110) Q 296.18 F=0 F 0.00 PE 0.00 FM T 8.00 0.1816 PF 1.45 3-3 10-9DQ . 104.8-6 _ __2_.727 L 12.1/--C=120 --PT-1:7:n_(10 Q 401.04 F=0 F 0.00 PE 0.00 FM T 12.17 0.3182 PF 3.87 23 33 2.727 L 2.00 C=120 PT 21.19 ( 33) Q 401.04 F=T/T F 40.00 PE 0.87 FM T 42.00 0.3182 PF 13.36 22 23 6.357 L 10.50 C=120 PT 35.42 ( 23) Q 401.04 F=0 F 0.00 PE 0.00 FM T 10.50 0.0052 PF 0.05 PT 35.47 ( 22) 107 108 2.727 L 8.00 C=120 PT 15.02 (108) Q 97.68 F=0 F 0.00 PE 0.00 FM T 8.00 0.0233 PF 0.19 106 107DQ 98.29 2.727 L 8.00 C=120 PT 15.21 (107) Q 195.97 F=0 F 0.00 PE 0.00 FM T 8.00 0.0846 PF 0.68 105 106DQ 100.45 2.727 L 8.00 C=120 PT 15.89 (106) Q 296.42 F=0 F 0.00 PE 0.00 FM T 8.00 0.1819 PF 1.46 32 105DQ 104.95 2.727 L 12.17 C=120 PT 17.35 (105) Q 401.36 F=0 F 0.00 PE 0.00 FM T 12.17 0.3187 PF 3.88 22 32 2.727 L 2.00 C=120 PT 21.23 ( 32) Q 401.36 F=T/T F 40.00 PE 0.87 FM T 42.00 0.3187 PF 13.39 SUBMITTAL SERIAL NO:2244HY1 03-06-2008 PAGE 3 TI7175 RYDER PALLET STORAGE T.I. INDOOR STORAGE OF IDLE WOOD PALLETS (12) K25 ESFR SPRINKLERS FLOWING AT 15 PSI MIN. 97.60 GPM FILE = TI7175.SIG Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 21 22DQ 401.04 6.357 L 10.50 C=120 PT 35.49 ( 22) Q 802.40 F=0 F 0.00 PE 0.00 FM T 10.50 0.0186 PF 0.20 PT 35.69 ( 21) 103 104 2.727 Q 97.97 FM 102 103DQ 98.58 2.727 Q 196.55 FM L 8.00 C=120 PT 15.11 (104) F=0 F 0.00 PE 0.00 T 8.00 0.0235 PF 0.19 L 8.00 C=120 PT 15.30 (103) F=0 F 0.00 PE 0.00 T 8.00 0.0851 PF 0.68 101 102DQ 100.74 2.727 L 8.00 C=120 PT 15.98 (102) Q 297.29 F=0 F 0.00 PE 0.00 FM T 8.00 0.1829 PF 1.46 31 101DQ 105.25 2.727 L 12.17 C=120 PT 17.44 (101) Q 402.54 F=0 F 0.00 PE 0.00 FM T 12.17 0.3205 PF 3.90 21 31 2.727 L 2.00 C=120 PT 21.34 ( 31) Q 402.54 F=T/T F 40.00 PE 0.87 FM T 42.00 0.3205 PF 13.46 11 21DQ 802.40 6.357 L 110.00 C=120 PT 35.67 ( 21) Q 1204.95 F=0 F 0.00 PE 0.00 FM T 110.00 0.0395 PF 4.35 10 11 8.249 L 36.00 C=120 PT 40.02 ( 11) Q 1204.95 F=E/T F 59.00 PE 0.00 FM T 95.00 0.0111 PF 1.05 5 10 8.249 L 21.00 C=120 PT 41.07 ( 10) Q 1204.95 F=GV,ALV/E F 49.60 PE 9.10 FR T 70.60 0.0111 PF 0.78 3 5 8.265 L 25.00 C=140 PT 50.95 ( 5) Q 1204.95 F=T/E F 71.00 PE 2.17 UN T 96.00 0.0083 PF 0.80 2 3DQ 250.00 8.265 L 100.00 C=140 PT 53.92 ( 3) Q 1454.95 F=E/2E F 57.00 PE 0.00 UN T 157.00 0.0117 PF 1.84 SUBMITTAL SERIAL NO:2244HY1 TI7175 RYDER PALLET STORAGE T.I. INDOOR STORAGE OF IDLE WOOD PALLETS (12) K25 ESFR SPRINKLERS FLOWING AT 15 PSI MIN. 97.60 GPM FILE = TI7175.SIG 03-06-2008 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 1 2 8.000 L 0.01 C=140 PT 55.76 ( 2) Q 1454.95 F=DD1 F 0.00 PE 0.00 UN T 0.01 0.0137 PF 0.00 8" WILKINS MODEL 350DA DOUBLE DETECTOR ASSEMBLY 4.57 1 Q 1454.95 8.265 L 20.00 C=140 PT 60.33 ( 1) F=T,GV/2E F 96.00 PE 0.00 UN T 116.00 0.0117 PF 1.36 PT 61.69 ( 0) 4". wr r ••6, ' • • • t•--,7* City of Tukwila Fire Department MAY 5 1995 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM ' Thomas P. Keefe, Fire Chief Permit No. L 006A> Project Name E72 -DX . Address /n9/ Adve, 144eZ Retain - Retain current inspection schedule KNeeds shift inspection Suite # Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature Signature Date FINALAPP.FRM T.F.D. Form P.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439 >a.>4 r.` s'"'rT'4n'ry+r�.[?' rw'....r .....v,... --:"-r.--" ...` R �....,.i.- ( rr City of Tukwila Fire Department T' n'c"<.'t' r MAY 5 1998 John W. Rants, Mayor TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name X - 0,(4-X Address Permit No. Thomas P. Keefe, Fire Chief /67/ 4444 Retain curr_4K ent inspection schedule Needs shift inspection Suite # .5C Approved withoutcorrection notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Authorized Signature 9S - Date FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Pant East • Tukwila, Washington 98188 • Phone: (206) 575-4404 • Fax (206) 575-4439