Loading...
HomeMy WebLinkAboutPP - 14220 INTERURBAN AVE S - FAIRWAY CENTER / VASCULAR ACCESS CENTER - PERMITS AND PLANS (2)14220 INTERURBAN AVE S ASSOCIATED PERMITS 08-F-374 EL08-0971 D08-349 164-13 FAIRWAY CENTER INSPECTION NUMBER INSPECTION RECORD Retain a copy with 7:L r w (1) 0 Dob -3L d8 -f- 37y PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: F;4ver,,,y co„tuc, ald. A Type of Inspection: f,4 A-Iwi..,.4 / 5Awl l_l. .sl ..,,,., Address: i Y22 -o Z A S- Suite #: /SD Contact Person: Special Instructions: Phone No.: 0G - 37/ — i'1 S Y [✓ Approved per applicable codes. Corrections required prior to approval. COMMENTS: /7' /(.7 S7Q021:7G5 C3Gu• ) D,6 L -G. s cd.6 :7; - 4 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: $WS75 Date: 7/2_,JAJr Hrs.: $80.00 REINSPECTION FEE REQUIRED. You will receive an invoice from t e City of Tukwila Finance Department. Call to schedule a reinspection. Word/Inspection Record Form.Doc 1/13/06 T.F,D. Form F.P. 113 TUKWILA KM ? VII\ITTON BURBAD. 444 Andover Park East,.Tukwila, WA 98188 - Phone 206-575-4407 - Fax 206-575-4439 E-mail: tukfdpry@ci.tukwila.wa.us CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alaun System is ready for Fire Department acceptance testing, Failure of test will result in termination of the testing and additional fees will b.e assessed. Contractor is resp onsibile'for supplying manpower for Final Acceptance Test with two-way communications. ' Date 7- 3 Permit#1t-0yj-o )./ Property Address. k cf2. Z v I"te✓ A • Suite # I SI) City Tukwila Name of Facility Fc, Occupied as Zip Code, 948(L� Owner or Representative G4 Phone # a- S- 0 -24_§. - Installing 76� Installing Company Installing Contractor's Address City S 111 < ( (vim Installer's Name (PRINT) 6 1J j Phone # 2-0C 3 43 - 13 c License and/or Certificate r I F i- E E L Co Z General Contractor w'1511: tor\ A (Gr v✓\ Electrical Contractor w FACP Equipment Manufacturer • , A:0"1. ' 5 Model # 7 L.( 17 - This Z This system has been installed, pre -tested and operates in'accordance with the standards listed below and. was inspected by 4 Sh n t � (4,/, On (date) and includes the devices listed on back. Circle all that apply: NFPA 72, Chapter 1 2 4 5 6 7 and/or LPC SEC 907 . - ✓ NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other (specify) Tukwila City Ordinance Numbers 2050, 2051. UL Central Station Monitor SIGNED System Firmware: ---- installed -version Ch ksum Date Initial program 1e2 • System is monitored. by {- ' A 5 , fon 4 Date EQUIPMENT INSTALLED AND TESTED: Control Panel of Make/Model Manual Station of Make/Model Smoke Detectors of Make/Model Heat Detectors of . Make/Model Duct Detectors. of Make/Model AN Devices 1 of f Make/Model 5y 57 e,nn Se's sof Audio Devices of Make/Model . Visual Devices 2 of '1 Make/Model $ / 5 - ew, 5 0 sot- Auto or Auto Door Release of Make/Model Trouble Indictors - of Make/Model Batteries Readings Battery Full Load . Charge Generator — of Make/Model HVAC Controls of Make/Mo.del Fire Alarm Dialer of . . Make/Model Monitored by Annunciator of Make/Model ❑ Sprinkler System. (Fire Alaini connections only) Water Flow.Sw, of Make/Model Valve Tamper Sw. of Make/Model I'IV of Make/Model Elec. AlarxnBell of Make/Model Automatic time Delay of Water Plow Alarm seconds. None Installed Do you meet audible/visible requirements of WAC 51-20,1 'C -SEC 907., and/or NFPA 72 Chapter 6? . Yes No Test of alarm System on emergency power, satisfactory? Yes _ No Test Witnessed by Title Date Comments: Date: 3/19/13 TUKWILA FIRE DEPARTMENT OPERATIONAL PERMIT 164-13 By virtue of The Provisions of the International Fire Code adopted by City of Tukwila Ordinance, Vascular Access Center of Seattle, LLC located at 14220 Interurban Avenue South, #110 having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *To store, transport on site, dispense, use or handle at normal temperatures and pressures compressed gases in excess of the amounts listed in Table #105.6.9 per Chapter 30 of International Fire Code 105.6.9. This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -Eighteen Calendar Months - This permit does not take the place of any License required by law and is not transferable. Any change in use or occupancy of premises shall require a new Hermit Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE Special Permit Long.doc Rev. 11/1/04 T.F.D./F.P. #2