HomeMy WebLinkAboutST - 12400 EAST MARGINAL WAY SOUTH - GROUP HEALTH - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) 1 ABOVE GROUND STORAGE TANKS (AST) 12400 EAST MARGINAL WAY SOUTH PARCEL NUMBER(S) 7340600480 RELATED PERMIT NUMBER(S) 122-12 Date: 2/16/12 Tukwila Fire Department OPERATIONAL PERMIT By virtue of the provisions of the International Fire Code adopted by City of Tukwila Ordinance, Puget Sound Construction Services located at 12400 East Marginal Way South 122-12 having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *To install or remove any flammable or combustible liquid tank per Chapter 34, section 3404 of the International Fire Code* This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -NINETY DAYS - This permit does not take the place of any License required by law and is not transferable. Any change in use or occunancv of premises shall reauire a new nermit. Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE. Puget Sound structs®n Services Inc. Jeff Dennison Office: 253491-2338 Fax: 253-826-3829 CeII: 253-334-26 Email: pugetsoundconsOmsn.com 20825 SR410 E #307 Bonney lake WA 48391 T.F.D./F.P. #2 Con TUKWILA FIRE DEPARTMENT UNDERGROUND/ABOVEGROUND FUEL TANK REMOVAL/INSTALLATION PERMIT FIRE DEPARTMENT SPECIAL PERMIT # P712 RECEIPT #92773 DATE RECEIVED: —/4'' /z DATE ISSUED: .2 4 -/ 2 FIRM NAME: fV,P ! Sound G ii S74rvc/ i or, rerv/GPSPHONE: 25:1--01-21-re FIRM ADDRESS' / 2 4ov 6.457L' 4r�;,� fi!/ g) S', 4'wi /44) JOB SITE: 2682 r 5A 9/c t. 7/ 30 An,07,44, IN . 9 P' 9 NUMBER OF TANKS TO BE REMOVED/INSTALLED: / /1'6e7/4sj Svtipv INDIVIDUAL TANK CAPACITY (GALS): PRODUCT TO BE STORED: b/PSe TOTAL AGGREGATE CAPACITY (GALS): NAME OF BUSINESS AT JOB SITE: 6 rove Hear /71-4 PERSON IN CHARGE: FF DPn/ns01 PHONE: 2-s'333 f23Sf To install or remove any flammable or combustible liquid tank per Chapter 34, section 3404 of the International Fire Code. Installation of aboveground tanks shall be limited to MIC/H, MIC/L, LI and C/LI zones. A site plan showing property lines, building location(s), storm drain location(s), public access, proposed screening and containment must be submitted for review prior to approval. THIS APPLICATION MUST BE RETURNED WITH A SCALED DRAWING OF THE SITE AND YOUR CHECK IN THE AMOUNT OF $ /Oa , TO THE TUKWILA FIRE DEPARTMENT, 444 ANDOVER PARK EAST, TUKWILA, WASHINGTON, 98188. TANKREMV.PER Rev. 11/1/07 T.F.D. Form F.P. 31 Group Health Cooperative AMB Receiving 12400 East Marginal Way S. Tukwila, WA. 98168 2-15-2012 eyWiv Vew-fs /24t " EASt /fm ,,'14/ k/'a, 5'• T�Xw�Ila , Rvet U (OIL...1;1 e�►sfie s''pp!, Fuel (int 4 etlist%1 cucor Rwe seciewa(4. New Ftoff y�sf corofetinsuegit suss., Aitven Fvef /At --+ Neu✓ Ta•, �' Ma1t�t°r Riser 4 peirk /074 •elc;sh:,y Tivk F,'l1 Puget Sound Construction Services Inc. 20825 SR 410 East #307 Bonney Lake, WA. 98391 1253)891-2338 Fax. (253)826-3829 Scope of Work: 1. Provide labor and equipment to saw cut, demo, and dispose of concrete vault on north tank around piping at east end of (1) storage tanks 2. Provide new equipment for tank- includes (1) 48"fiberglass containment sumps with bottom and top hat closure, (2) sump to tank adaptors, (4) sump penetrations, (1) check valve, (3) 2" ball valves, (1) 36" water tight man ways, All required steel and fiberglass piping materials needed to retrofit lines 3. Provide labor and materials to intercept supply and return lines and retrofit lines into (1) new containment sumps installing ball valves on each line on north tank only 4. Provide labor and materials to install (1) 2" ball valve on other tank return line for isolation purposes 5. Provide labor and materials to install an uncontained access port over south tank return line ball valve 6. Provide labor and materials to remove and plug old existing copper tube tank monitor bung 7. Provide labor to air test lines after retrofit 8. Provide electrician to disconnect, remove, and reinstall conduit and wire and relocate. One conduit in containment sump for leak sensor and extend one conduit out of sump to 3" tank top riser for level gauge 9. Provide technician to reprogram and restart up tank monitor 10. Provide labor and equipment to backfill, compact, and prep area over top of tanks replacing with clean pea gravel fill material 11. Provide clean wash pea gravel to back fill and cover lines and tanks 12. Provide city of Tukwilla fire permit 13. Provide and submit all notifications with Department of Ecology STANDARD CONFIGURATION: FRICTION FIT LID 0 D ID LID/OD RISER 0 A ID TYPE B WATER RESISTANT DIMENSION TABLE A B C D NOTES: - ALL RISERS AVAILABLE CENTERED OR OFFSET - OPTIONAL WALL CONSTRUCTION SINGLE OR DOUBLE TYPE A WATER TIGHT MULTIPORT PHILTITE OPW CNI Western Fiberglass Inc. Santa Rosa, Calif. 800 688-3375 Fax 800 700-1188 www.westernfg.com DESCRIPTION TANK SUMP (36" , 42" , 48" or CUSTOM DIA. AVAILABLE) MODEL 1 PART # DRAWN 08-18-05 DL SCALE SHEET 1 OF 1 Western Fiberglass - Single Walled Sumps - Specifications Page 2 of 3 Sumps Single Walled Double Walled Flat Sided Filament Wound Sump Riser & Reducers Summary The Filament wound sump riser and riser reducer shall be installed onto the underground storage tank and in accordance with the manufacturers installation instructions. The UST sump riser and riser reducer shall provide an open piping termination and inspection/service area that is non -permeable to hydrocarbons, compatible with all fuel blends, and will not hold a static electrical charge. The sump system shall contain environmentally hazardous fluids that might leak from piping terminations, fittings and flex -hoses contained within the sump, require no internal back -fill or bracing and be self supporting. The sump shall be manufactured by Western Fiberglass, Inc. System Specifications 1.01 System Suitability The Tank Sump Riser Tube and Riser Reducer Assembly shall: A. Attach to the UST manway, bung fitting or containment collar to prevent the intrusion of ground water into the sump assembly. B. Be of sufficient size to allow all piping termination's, fittings, equipment, and flex -hoses to be contained within the Sump Assembly. C. Provide ample area to allow servicing and inspection of all piping termination's, fittings, equipment, and flex -hoses within the Sump Assembly. D. Contain any release of environmental contaminates from the tank fittings and equipment contained within the Sump Assembly. E. Provide an interface to the access "street" manway system with sealed water tight or friction "lift -lid" Tank Sump Riser Tube Reducer Assembly. F. Be available as a U.L. Listed device if required. 1.02 Construction Specifications A. Meet or exceed United States National Bureau of Standards PS 15-69 for Custom Contact -Molded Reinforced -Polyester Chemical -Resistant Process Equipment or U.L. Listing if applicable. B. Be constructed of materials that are not harmful to the environment. C. Be non -permeable to the hydrocarbons and not weakened by exposure to these materials. D. Be suitable for petroleum products and blends including methanol and ethyl alcohol mixtures. E. Have a thirty (30) year warranty against corrosion. 1.03 Release Monitoring System shall: A. Allow full visual and physical access/inspection of all piping reductions, fittings, hoses, and equipment. B. Provide a monitor point for electric monitoring and evacuation of fluids. 1.04 Piping Penetrations A. Provide locations for the installations of fluid tight pipe and conduit penetration seals to be installed according to manufacturer's instructions. http://www.westernfg.com/sumpswspecs.html 2/15/2012 ICC: International Code Council ��®�► 500 New Jersey Avenue, NW ®rhe Washington, DC 20001 INTERNATIONAL CODE COUNCIL! The individual named hereon is CERTIFIED in the categories shown, having been so certified pursuant to successful completion of the prescribed written examinations. :... _y..�, .,.�.,.a.,o.r... a."#(00 rt ►t valid unless signed by certificate holder. ICC Certification attests to competent knowledge of codes and standards. Jeffrey W Dennison - 878740 UST Installation/Retrofitting - Exp. 04/15/2013 Department of Labor and Industries PO Box 44450 Olympia, WA 98504-4450 PUGET SOUND CONST SERVICES INC Reg: CC PUGETSC995OQ UBI: 602-140-269 ;Registered as provided by Law as: Construction Contractor (COO I )- GENERAL PUGET SOUND CONST SERVICES INC` 20825 SR 410 E #307 BONNEY LAKE WA 983916301' Effective Date: 9/18/2001 Expiration Date: 2/1/2014