Loading...
HomeMy WebLinkAboutST - 10215 EAST MARGINAL WAY SOUTH - NESS & CAMPBELL CRANE - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) 1 ABOVE GROUND STORAGE TANKS (AST) 10215 EAST MARGINAL WAY SOUTH PARCEL NUMBER(S) 423049002 RELATED PERMIT NUMBER(S) 341-13 342-13 343-13 344-13 385-10 386-10 387-10 388-10 389-10 Date: 5/12/10 Tukwila Fire Department OPERATIONAL PERMIT By virtue of the provisions of the International Fire Code adopted by City of Tukwila Ordinance, 385-10 Ness & Campbell Crane, Inc. located at 10215 East Marginal Way South having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *To install or remove any flammable or combustible liquid tank per Chapter 34, section 3404 of the International Fire Code* This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -NINETY DAYS - This permit does not take the place of any License required by law and is not transferable. Any change in use or occunancv of premises shall reauire a new hermit. Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE. T.F.D./F.P. #2 • SME SOLUTIONS, LLC Bill To: NESS Crane Brand Name: Inde Address: 2302 A Street Tacoma, WA 98402 (253) 5723822 Fax (2572.0978 • COD $75 Station #: 10215 10215 E Marginal Way 6550 N. Interstate Ave. Work Order # Portland, OR 97217 (503) 286-3728 Fax (503) 286-5395 471159 City: Tukwila, WA 98168 - Reference#: Need Date: Feb 8, 2011 Closed with: PO/ Release #: COD SME Ref. #: 78838 Assigned To: Zeus Moreno Category: PM/Testin Item #: Part #: 9 Component: _Note: Prec. Tank Tett Failure: Compliance Action: Cc /d?' Qty: Warranty/DOA Price: Amount Parts Description: I'4 1 Notes: TeS-I-/1)n, X45 r >/';76s0�1 1 L,`4, - //MI6 ' dZj 7 k fill �s f oto 1vim' i!,a / -4A h '/ I.— 7.---/lie `'r ` ! /lie 242, Labor Hours: Travel Hours: Total Hours: T/OT Labor Rate Amount Date: l fr Tech: leg Start:S' O(0 PM Stop: -3 dia•M 8 250.s-- t%' Date: J Tech. ,. , Start:g •(AO PQM Stop: 17' ,r) y - (7 '' '') 4-0 r" Category: Component: Failure: Item #: Note: Action: art #: Parts Description: Qty: Warranty/DOA Price: Amount Notes: AM AAA Date: Tech: Start: PM Stop: PM AM AM Date: Tech: Start: PM Stop: PM Labor Hours: Travel Hours: Total Hours T/OT Labor Aate Amount Sometimes one service call does not resolve all specific problems due to detective equipment or intermittent problems not present or which cannot be duplicated when our Service Technician is et your premises. Some equipment requires removal on one trip, in-house repair. and another trip for reinstallation. Charges will be made for each service calf at rates in effect at time of service. We, therefore, cannot warrant solutions t0 all problems on one service call. Time 'Arrived" and time 'Departed" recorded by our Service Technician will be the guideline used in recordation of repair time and charges. It Is the customer's responsibility to audit and verify times recorded on the invoice by our Service Technician while he/she is on your promises. We cannot and will not alter any time charges billed after our Service Technician has raft your premises. 1 underst d & acceall terms & conditions as outlined on workorder. Subtotal Materials $ Mileage S Markup S Subtotal Labor S Sales Tax $ Total Labor /Travel $ Total Materials $ L ASE PAY BY INVOICE TERMS Total Invoice �'� ►moi I ni SME SOLUTIONS, LLC 2302 "A" Street — Tacoma, WA. 98402 (253) 572-3822 Fax (253) 620-5261 February 11, 2011 Ness & Campbell Crane PO Box 70545 Seattle, WA. 98127 Attention: Bob Schow Reference: Tank testing one Convault tank located at 10215 East Marginal Way, Tukwila, WA Mr. Schow, On February 8th, 2011, SME Solutions complete testing of one double wall tank with two compartments. The test was conducted per the manufactures instructions with passing results. Please let me know if you have further questions. Thank you, Jeff Stephens Environmental Service Manager SME Solutions LLC 2302 A Street Tacoma, WA t ---HA SME SOLUTIONS, LLC 2302 "A" Street — Tacoma, WA. 98402 (253) 572-3822 Fax (253) 620-5261 PRESSURE TEST DATA CHART Customer Ness & Campbell Crane, INC Date Febuary 8`h 2011 Address 10215 E Marginal Way Tukwila, Wa 98168 IDENTIFY EACH LINE TESTED TIME (MILITARY) LOG OF TEST PROCEDURES, AMBIENT TEMPERATURE, WEATHER, ETC. PRESSURE TEST RESULTS CONCLUSIONS, REPAIRS, AND COMMENTS BEFORE AFTER Diesel 14:00 Start Test 3.00 PSI 3.00 PSI Compartment 1 Diesel Tank Tank 15:00 2.99 PSI Tank PASSED Diesel 14:00 Start Test 3.05 PSI 3.05 PSI Compartment 2 Diesel Tank Tank 15:00 3.03 PSI Tank PASSED Test Required By: Test was,en one diesel tank with two compartments. TANK PASSED Tester's Signature: Printed Name: Zeus Moreno Date: 02-08-2011 1 . Date: 5/12/10 TUKWILA FIRE DEPARTMENT OPERATIONAL PERMIT 385-10 387-10 388-10 389-10 By virtue of The Provisions of the International Fire Code adopted by City of Tukwila Ordinance, Ness and Campbell Crane, Inc. located at 10215 East Marginal Way South having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *For the use, storage or handling of flammable or combustible liquids in aboveground storage tanks per Chapter 34, sec. 3404.2.9 of International Fire Code 105.6.17 and City Ordinance #2047.*For the storage and use of LP -gas and operation of cargo tankers that transport LP -gas per Chapter 38 of International Fire Code 105.6.28. *For operation of repair garages and automotive, marine and fleet motor fuel -dispensing facilities per Chapter 22 of International Fire Code 105.6.40. *To conduct hot work per Chapter 26 of International Fire Code 105.6.24. This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -Eighteen Calendar Months - This permit does not take the place of any License required by law and is not transferable. Any change in use or occupancy of premises shall require a new Hermit Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE Special Permit Long.doc Rev. 11/1/04 T.F.D./F.P. #2 Date: 5/21/13 •r TUKWILA FIRE DEPARTMENT OPERATIONAL PERMIT 341-13 342-13 343-13 344-13 By virtue of The Provisions of the International Fire Code adopted by City of Tukwila Ordinance, Ness & Campbell, Inc. located at 10215 East Marginal Way South having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted *For the use, storage or handling of flammable or combustible liquids in aboveground storage tanks per Chapter 34, sec. 3404.2.9 of International Fire Code 105.6.16 and City Ordinance #2290. *For the storage and use of LP -gas and operation of cargo tankers that transport LP -gas per Chapter 38 of International Fire Code 105.6.28. *For operation of repair garages and automotive, marine and fleet motor fuel -dispensing facilities per Chapter 22 of International Fire Code 105.6.39. *To conduct hot work per Chapter 26 of International Fire Code 105.6.23. This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR -Eighteen Calendar Months - This permit does not take the place of any License required by law and is not transferable. Any change in use or occupancy of premises shall require a new permit Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE Special Permit Long.doc Rev. 11/1/04 T.F.D./F.P. #2 S4uNO TESTING, INC PO..sok 1620i SEATTLEW/4198116 (206) 932-0206 FAX (206) 937-3848 VeeseiOwnerOrAgent idriZfadilf(, fy Typqiii.e7 7 "4'4 L4it . ✓ SPedfic Location •of Vseeel ectszat 0,44 /TePts Aimed Lir I 446-, Tv , stix,s 17p sM' ezir v a PI'Afi Ai 4J4 raiz In the event of any physical or atmospheric chances adversely affecting the gas -free condition of thu ,shove spaces. or if in any doubt immediately stop all work and contact the undersigned Marine Chr,nn .: QUALIFICATIONS: Transfer of ballast or manipulation of valves or closure equipment tending to alter conditions in pipe lines, tanks or compartments subject to gas accumulation, unless specifically approved in this Certificate, requires inspection and endorsement or reissue of Certificate for the spaces so affected. All lines, vents, heating coils, valves, and similarly enclosed appurtenances shall be considered "not safe" unless otherwise specifically designated. STANDARD SAFETY DESIGNATIONS SAFE FOR WORKERS Means that in the compartment or space so designated (a) the oxygen content of the atmosphere is at least 19.5 percent by volume, and that, (b) toxic materials in the atmosphere are within permissible concentrations, and that, (c) the residues are not capable of producing toxic materials under existing atmospheric conditions while maintained as directed on the Menne Chemist's Certificate NOT SAFE FOR WORKERS Means that in the compartment or space so designated, the requirements of Safe for Workers has not been met. $AFE FOR HOT WORK: Means that in the compartment so designated: (a) oxygen content of the atmosphere is at least 19.5 percent by volume, with the exception of inerted spaces or where external hot work is to be performed; and that, (b) the concentration of flammable materials in the atmosphere is below 10 percent of the lower flammable limit and that, (c) the residues are not capable of producing a higher concentration than permitted by (b) above under existing atmospheric conditions in the presence of fire, and while maintained as directed on the Marine Chemist's Certificate; and further, that, (d) all adjacent spaces have been cleaned sufficiently to prevent the spread of fire, or are satisfactorily ineited, or, in the case of fuel tanks, or lube oil tanks, or engine room or fire room bilges, have been treated in accordance with the Marine Chemist's requirements. NOT SAFE FOR HOT WORK Means that in the compartment so designated, the requirements of Safe for Hot Work have notbeen met CHEMIST'S ENDORSEMENT This is to certify that I have personally determined that all spaces in the foregoing list are in accordance with NFPA 306 Control of Gas Hazards on Vessels and have found the condition of each to be in accordance with its assigned designation. 'The undersigned acknowledges receipt ct this Certificate under Section 2-6 of NFPA 306 and This Certificate is based on conditions erdsting at the time the inspection herein set forth was completed understands conditions and limitations under which it was issued.' and is Issued subject to compliance with all qualifications and instructions. Name 4-1 1rxiar,/ Signed i Al ,il w z!:_ 4 1