Loading...
HomeMy WebLinkAboutST - 15034 GRADY WAY - FAMILY FUN CENTER - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) I ABOVE GROUND STORAGE TANKS (AST) 15034 GRADY WAY RELATED PERMIT NUMBER(S) 93-98 M I91-0218 City of Tukwila AUG 1 4 1998 John W. Rants, Mayor Fire Department Thomas P. Keefe, The Chief TUKWILA FIRE DEPARTMENT FINAL APPROVAL FORM Project Name i y F`� Address 1 S 03 4i 6-r4,i y - Permit No. /vl / /2-0A 1� Retain current inspection schedule Needs shift inspection Suite # 7( Approved without correction notice Approved with correction notice issued Sprinklers: Fire Alarm: Hood & Duct: Halon: Monitor: Pre -Fire: Permits: Ff2o M S Authorized Sig ature FINALAPP.FRM T.F.D. Form F.P. 85 Headquarters Station: 444 Andover Park East • Tukwila, Washington 98188 • Phone: (206) S7S-4404 • Fax (206) 575-4439 • 0 TUKWILA FIRE DEPARTMENT UNDERGROUND/ABOVEGROUND FUEL TANK REMOVAL/INSTALLATION PERMIT PERMIT # C6-98 8 RECEIPT # I117(9 DATE RECEIVED 7-1M-98 DATE ISSUEDZ�L 4^9 U FIRM NAME: CODE REFERENCE: 7901.3 6- OENC,!vEerts (-r) PHONE : b c f-60 S_ % FIRM ADDRESS: 8100 /0441' A-*- /11 En d aAV) JOB SITE: f it.1/ fu/V Cf f TEy( Ge)r NUMBER OF TANKS TO BE REMOVED/INSTALLED: I INDIVIDUAL TANK CAPACITY (GALS): S-00 TOTAL AGGREGATE CAPACITY (GALS): NAME OF BUSINESS AT JOB SITE: -A1"''I� f CFA,TEK PERSON IN CHARGE: LISW g OP')3 PHONE�tid SSG/-G')S 7 To install, alter, remove, place temporarily out of service or otherwise dispose of any flammable or combustible liquid tank per 79.116 of the Uniform Fire Code. Installation or removal of underground tanks having an individual capacity or total aggregate capacity of greater than 10,000 gallons, and installation or removal of underground tanks located within 200 feet of the Green/Duwamish Rivers requires approval of the Tukwila Planning Department. All aboveground tank installations require approval of the Tukwila Planning Department. Installation of aboveground tanks shall be limited to MICH, MICL, HI, LI and C/LI zones. The Tukwila Planning Department will require submittal of a site plan for review prior to approval. Planning Department: Approved Signature: Not Approved Date: No fire department permit will be issued without Tukwila Planning Department approval when required. THIS APPLICATION MUST BE RETURNED WITH A SCALED DRAWING OF THE SITE AND YOUR CHECK IN THE AMOUNT OF $ So"`' , TO THE TUKWILA FIRE DEPARTMENT, 444 ANDOVER PARK EAST, TUKWILA, WASHINGTON, 98188. TANKREMV.PER Rev. 6/96 T.F.D. Form F.P. 31 209-237-3413 TRUSCO TANK -FRESNO \ 214 PO4 DEC 02 '98 11:18 MHR Gas Disp Pkg with Phase I & II Vapor Recovery MHRE332 LEAK DETECTION TUBE - 16 GALLON INTEGRAL — SPILL CONTAINMENT PAN4 ii) 0, N r L COMPONENT DESCRIPTION ' 1. TESTING WELL PWG' 2. PRESSURE/VACUUM VENT VALVE. J 2" CALV. VENT ARE 4. 2" COUPLER5(2) ' 5. EMERGENCY VENT PART NUMBER MORRISON 678XA. 2' oww //3235 Pv VENr Boz 6. LEVEL GAUGE 1 FILL ADAPTOR 8. FILL CAP 9. DROP TUBE is J/4' GRAIN VALVE 11, VAPOR RELIOVERT CAP 12. VAPOR RECOVERY ADAPTOR 1J. PUMP NMTN AIETER, NO AND H000 14. 0VERhEA0 HOSE RETRACTOR IS. HOSE RETRACTOR POST 16. COAXIAL ADAPTOR. Si. FILTER ADAPTOR It FILTER ELEMENT 19. ,JUMPER NOSE 20. COAXIAL NOSE ASSEMBLY. 21. VAPOR RECOVERY NOZZLE. 22. 1- SUCTION PEE, BLACK 21 DECAL KIT MORRISON / 244 LS 4' or r KRUEGER / INI,RMA-CAUCE; TYPE N-2 MORRISON J05-000 AA MORRISON 800 OCA040 OUST CAP MORRISON / 419, 2' OPW / 171t -T-708.5 OPw / 1s11 -AV -1620 FILL -RITE / FR702 /or Gasoline PoMECO / 102-6P TT!/7,234 tww/38-c aM-TEK / 200N -J-4 C191 -TE' / 300-10 THERMc4D / 1481-024, J/4' x 24" ma THERAIOO SUPER -111E N-FlO COAX / 9999 -Ill OPW / 11VF-0422 (leaded) OPW / 111,-0427 (unleaded) swivel NOTE. 2' VENT RISER /S SNIPPED LOOSE. A 2' PLASTIC SHIPPING PLUG IS INSTALLED IN VENT FITTING 10 BC REMOVED PR/M TO ATTACNANC VENT RISER PHASE 1 & PHASE 11 BALANCE VAPOR RECOVERY GASOLINE DISPENSING SYSTEM FOR SUPERVAULT MH RECTANGULAR TANKS [nyn.M — 7}..8irvfiry retiqe1 r ..wry..iMwi media. TRUSCO TANK INC. (800) 800 -TANK SUPERVAULT® MH MULTI -HAZARD RATED, PROTECTED TANK NTS : RCV 3ION N.. : I1CVI$Tae an : CIAfl G wan 4/32/60 L 0 I. 6/26/96 6.33,? 209-237-3413 TRUSCO TANK -FRESNO �...1 SET SCREWS 4" TANK NOZZLE H 214 P03 DEC 02 '98 11:17 MATERIAL LIST 1. 2" DROP TUBE. CUT TO LENGTH 2. FLOAT OPERATED VALVE 3. 4" ADJUSTABLE COLLAR 4" FNPT 4. 2" FILA PIPE, CUT TO LENGTH S. 2" ADAPTER. MORRISON / 305-0000AA 6. 2" LOCKABLE CAP, MORRISON / B000CA-0400 LIGHTWEIGHT CONCRETE TANK INSULATION TOP OF' TANK 6" TANK BOTTOM NOTES • THIS SYSTEM PROVIDES POSITIVE OVERFILL PREVENTION ON PRESSURIZED DELIVERIES TO ABOVEGROUND TANKS. UPON DISCONNECTION OF SUPPLY HOSE. FUEL IS AUTOMATICALLY DRAINED FROM THE UPPER FILL PIPE. • SHUTOFF VALVE INSTALLS ON 4" NPT TANK NOZZLE. • FILL PIPE IS POSITIONED SO THAT THE SHUT OFF POINT (DIMENSION H) IS LOCATED AT 90X OF TANK CAPACITY AND THEN SECURED IN PLACE. • DROP TUBE IS POSITIONED SO THAT THE CUT END IS A MAXIMUM OF 6" ABOVE THE TANK BOTTOM. • THE FILL ADAPTOR IS DESIGNED TO BE DIRECT COUPLED ONTO A CAM -LOCK SPOUT ON THE NOZZLE OF THE FUEL DELIVERY TRUCK. THE CAP IS LOCKABLE. ijPERVA.ULT Mif AUTOMATIC SHUTOFF VALVA TRUSCO TANK INC. (800) 800 -TANK T SOrelaoNona Jwjett to [Mktg, Mwn•wi arse SUPERVAULT TTM MB MULTI -HAZARD RATED, PROTECTED TANK DA1 : . ; Rfrisl DMMIIING N NUM4/ 12/96 I UMW Uo0 6,16/96 ( 8.310 209 -23? -3413 TRUSCO TANK -FRESNO 60 POUR PORT 214 P05 DEC 02 '98 11:18 kOQEL N0. MHR-o-10oo S e aL oeu. oouTMNT PARTIAL I.E SFIOww) r. + }/4q L to 'azar 1TP_4 to Paw MR 6O EV PRWRV L2 • L1• TOP PLAN /-6-0 POUR PORT PARTIAL SIDE VIEW DIMENSIONS L1* L2 W1 W2 _ H Mabee 004. aa.. .+a». raw 132 88 71 74 53.38 * NielosOmATISt UYtlCtrgaZerfiLl END VIEW CUSTOMER APPROVAL; DATE: SHOP ORDER NO.; TTRUSCO TANK INC �SUPERVAULT MH MONITOR TUBE Slio.l�afii.**eldlloot b ch..mp, s4iWl mean PROTECTED ABOVE GROUND STORAGE t/ (800) 800—TANK .._ �� ' PROTECTED ABOVE GROUND STORAGE TANK a' REt�Idf AIIIIIMMIF 8/24/94 3 I 12//20/96 CRAW TER C 1 000 IMININIemmeN•K‘, POUR PORT r � 1 0 MWR-D-1500 gat 1T 47. Ti NOZZLE 11,-1 l L2 U TOP PLAN 11 wow DIMENSIONS 1.2 Ashes W1 Whom 132 88 96 W2 I H reklie 99.38 55 a Ace warosamety • TANK uPielN ipq OV[RAuLoam Neo•NAnow. flr'RMC CUSTOMER APPROVAL: DATE: SHOP ORDER NO.: TRUSCO TANK INC. II(800) 800—TANK TE:TT 866 Z0 03Q Ted STZ S *dile au eudW I. ehpe OMevf rootlet SUPEf?VAULT MH PROTECTED ABOVE GROUND STORAGE TANK DATE : ROA ; REVISION ANTE CRANING WNW • 8024/94 3 12/26 96 C1500 ONS3dd-NNdi OOSfldl ET0E-LEZ-60Z G MEAN HIGH HATER MARK BENCH AREA (ABOVE ORDINARY HIGH HATER MARK) NEH BOTTOM OP B 9 62-1"`c1/ • - • OVERALL SITE FLAN SCALE: r 7112 N moRT14 z IL t- 0 z I- 1 0 0 ri E 0.1 CO z • 0 Di• 0 Z Z VI W LLI til • Z 10 "lc s 4 8 Ne S D - 1 �O,I --H mill OII ( OII I !III I