HomeMy WebLinkAboutST - 18700 ORILLIA RD S - VERIZON WIRELESS - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) I ABOVE GROUND STORAGE TANKS (AST) 18700 ORILLIA RD S RELATED PERMIT NUMBER(S) 725-7 Date: 12/17/07 Tukwila Fire Department OPERATIONAL PERMIT By virtue of The Provisions of the International Fire Code adopted by City of Tukwila Ordinance, Verizon Wireless located at 18700 Orillia Road South 725-07 having made application in due form, and as the conditions, surrounding, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and the PERMIT is granted for *To install, alter, remove, abandon or otherwise dispose of a flammable or combustible liquid tank per Chapter 34 of the International Fire Code* This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT IS VALID FOR This permit does not take the place of any License required by law and is not transferable. Any change in use or occupancy of premises shall require a new permit -Ninety Days - Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE T.F.D./F.P. #2 '450 CCILIA TUKWILA FIRE DEPARTMENT UNDERGROUND/ABOVEGROUND FUEL TANK REMOVAL/INSTALLATION PERMIT FIRE DEPARTMENT SPECIAL PERMIT # RECEIPT #-Z,T, ' DATE RECEIVED: /Z -7/7-40 7 DATE ISSUED: FIRM NAME: Verizon Wireless (Contact: Jennifer Taylor) PHONE: 206-228-2127 FIRM ADDRESS: 14432 SE Eastgate Way Suite 260 Bellevue, WA 98007 JOB SITE: 18700 Orillia Road South NUMBER OF TANKS TO BE REMOVED/INSTALLED: One to be installed INDIVIDUAL TANK CAPACITY (GALS): 52 gallons PRODUCT TO BE STORED: Biodiesel fuel TOTAL AGGREGATE CAPACITY (GALS): 52 gallons NAME OF BUSINESS AT JOB SITE: Verizon cell site - SEA Brisco PERSON IN CHARGE: PHONE: To install or remove any flammable or combustible liquid tank per Chapter 34, section 3404 of the International Fire Code. Installation of aboveground tanks shall be limited to MIC/H, MIC/L, LI and C/LI zones. A site plan showing property lines, building location(s), storm drain location(s), public access, proposed screening and containment must be submitted for review prior to approval. THIS APPLICATION MUST BE RETURNED WITH ASCALED DRAWING OF THE SITE AND YOUR CHECK IN THE AMOUNT OF $ , TO THE TUKWILA FIRE DEPARTMENT, 444 ANDOVER PARK EAST, TUKWILA, WASHINGTON, 98188. TANKREMV.PER Rev. 11/1/07 T.F.D. Form F.P. 31 Tukwila Fire Department InterOffice Memo R.E COPY July 12, 2007 To: Finance & Safety Committee From: B/C Don Tomaso Re: Above Ground Diesel Fuel Tank Installation Issue: Verizon Wireless has requested a permit to install a standby power generator with an attached 210 gallon diesel fuel tank for their cellular site located at 18700 ' Background: Per City Ordinance 2047 and codified as TMC 16.16.040, the City restricts the installation of above ground fuel tanks to the following zoning classifications, MIC, LI, and CLI. The zoning for this location is TVSMPA, and exceptions have historically been approved by the City Council under TMC 16.16.090 and TMC 16.16.100. Discussion: The proponent's proposal is to install a standard Genset with an intergal fuel tank with a 210 gallon capicity. This Genset is typical for the use intended, and we currently have several installed within the City. Most notably, the ones you would see most are installed by the City at pump station locations (Andover Park West & Strander) and for ValVue Sewer District for their pump station locations (Boeing Access Road and East Marginal). The proponent has an operational need to install the Genset to insure system reliability for their celluar network, as with other busineses who discovered reliability issues as a result of the December wind storm and the timeliness of public utility power supply restoral. The proposed installation will be located within the King County Solid Waste Transfer Station site, specifically located on the West side boarding the WSDOT ROW for I — 5. The site is screened by a berm from I — 5, but is visible from the transfer site. I have told the proponant that landscape screening would be required, and they have agreed to installing landscape screening. I recommend that this variance be approved with provisions for the installation of landscape screening that is consistant with requirements from the planning department for type Ill landscape screening. Type Ill screening is what was required at the Cendant Rental Car facility on International Boulevard. DRAWING INDEX DWG' ' DESCRIPTION R O. T - I COVER SWEET 2 A -I SPECIFICATIONS 2 A-2 SITE PLAN 2 A-3 COMPOUND LAYOUT 2 A-4 EAST AND WEST ELEVATIONS 2 A -4A NORTW AND SOUTH ELEVATIONS 2 A-5 GENERATOR FUEL TANK 2 S -I STRUCTURAL DETAILS 2 E -I SINGLE LINE DIAGRAM 2 E-2 ELECTRICAL LAYOUT 2 E-3 GROUNDING DETAILS 2 Oct) nowi1 K� C 011 wireless SEA BRISCO GENERATOR INSTALLATION PROJECT SUMMARY SITE NAME: SITE ADDRESS: ASSESSOR'S PARCEL ": CURRENT ZONING: GOVERNING CODE: JURISDICTION: CONSTRUCTION TYPE: OCCUPANCY: PROPERTY OWNER: SITE ACQUISITION: ZONING CONTACT: PROJECT MANAGER: CONSTRUCTION MANAGER: APPLICANT: CONSULTANT: SURVEYOR: POWER: TELCO: PREVIOUS PERMIT APPROVALS: SEA BRISCO 18100 ORILLIA RD S TUKWILA, WA 352304-9031 TUKWILA VALLEY SOUTH (TVS) IBC 2005 CITY OF TUKWILA N/A N/A KING COUNTY 500 KING COUNTY ADMINISTRATION BUILDING SEATTLE, WA 58104 DANIEL BONNINGTON PHONE: (425) 214-4444 (EXT. 125) JENNIFER TAYLOR 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE,WA 55001 PHONE: (425) 214-4444 (EXT. 141) EMAIL: ,JtaylorereaIcomassoc.com JULEI HINTY PHONE: (425) 214-4444 (EXT. 125) CHRIS STEPHENS 15900 SE EASTGATE WAY BELLEVUE, WA 98005 PHONE: (425) 603-2128 VERIZON WIRELESS TRK ENGINEERING LTD "20I - 11685 - 56TH AVE SURREY, BC V35 1X1, CANADA CONTACT: DENNIS AMANTEA TEL: (604) 514-6432 FAX: (604 514-6431 TOLL FREE: 1-811-345-4045 EMAIL: MAILeTRKENGCOM N/A T.BD. T.B.D. MI99-0221 AND MI99-0203 5 188TH ST VERIZON WIRELESS SITE �4 v S 190TH LN S 192ND ST 4 F- KEY PLAN N.T.S. NAVP 88: GROUND ELEV.= T.BD. TRANSFER STATION ACCESS ROAD NAP 83 LAT. 41' 26' 0.1 N LONG. 122' 16' 10.5 W DIRECTIONS FROM BELLEVUE TAKE 1-405 (SOUTH). ROAD NAME CHANGES TO SR -5I5. TAKE RAMP (RIGHT) ONTO I-5 (TOWARDS I-5 / PORTLAND). AT EXIT 152, TURN RIGHT ONTO RAMP (SOUTH 188TH STREET / ORILLIA ROAD). KEEP LEFT TO STAY ON RAMP TOWARDS ORILLIA ROAD. TURN LEFT (SOUTH-EAST) ONTO SOUTH 188TH STREET. TURN LEFT (NORTH) ONTO ORILLIA ROAD SOUTH. ARRIVE AT 18100 ORILLIA ROAD SOUTH (TRANSFER STATION). SITE IS PAST TRANSFER STATION TOOL BOOTH ON LEFT SIDE. PROJECT DESCRIPTION -INSTALLATION OF A I2kW CABINET STYLE BIODIESEL DC GENERATOR WITH A 52 GALLON DOUBLE WALLED FUEL TANK ON CONCRETE PAD NEAR EXISTING VERIZON EQUIPMENT APPROVAL LIST TITLE SIGNATURE DATE RF ENGINEER PROJECT MANAGER SITE ACQUISITION ZONING CONTACT PROPERTY OWNER LEGAL DESCRIPTION REFER TO A-2 P®Wiwireless REALCOM 401 - 11600 - 66114 AVE SURREY, BC V36 1X1, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I-811-345-4045 EMAIL: mell"trkargcom 1.1.E15:II«: w614. oom PROJECT NO: 0630-020 DRAIN BY, GH. CHECKED ST, FPL CAD FILE: 0630.02011 SUBMITTALS 2 OCT 0/01 GENERATOR RES/SIGN .ANE 25/01 GENERAL REN6:0 40 MAY 14/01 165UED FOR SP/CONST. A APR 20101 ISSUED FOR REVIEW THE IN FOR'1ATION CONTAINED N TH16 SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE 011¢R THAN THAT WHICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. AIE SEAL SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SHEET TITLE COvER SHEET SHEET NUMBER T-1 GENERAL NOTES: I. THE PROPOSED INSTALLATION WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION. (NO HANDICAP ACCESS IS REQUIRED). 3. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY VERIZON WIRELESS TECHNICIANS. 4. NO NOISE, SMOKE, DUST OR ODOR WILL RESULT FROM THIS PROPOSAL. 5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED. 6. ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE LATEST VERSION. 1. THE TENDERER MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE SCOPE OF THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM WILL BE PAID FOR EXPENSES RESULTING FROM FAILURE TO DO SO. 8. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS 51-101154 ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONSTRICTION MANAGER 9. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES. 10. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAY, ETC. IS INDICATED AS PROPOSED LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON-SITE CONSTRUCTION MANAGER PRIOR TO THE START OF WORK II. ALL DAMAGE OR OPENING UP OF THE EXISTNG STRUCTURE MUST BE MADE GOOD TO THE FIE -CONSTRUCTION CONDITION OR BETTER. 12. INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE MINIMUM 24 HOURS NOTICE TO CONSULTANT. B. REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM TEE SITE THROUGHOUT THE DURATION OF THE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY THE CONSTRUCTION MANAGER 14. OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION OF WORK AND ACCEPTANCE. PROVIDE CERTIFICATES TO THE CONSTRICTION MANAGER VERIFYING THAT THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND AUTHORITIES HAVING JURISDICTION IS. PROVIDE VERIZON WIRELESS WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER DATE OF ACCEPTANCE, FOR THE COMPLETE INSTALLATION. REPAIR OR REPLACE ANY DEFECTS ARISING DURING THIS PERIOD AT NO EXTRA COST TO VERIZON WIRELESS. 16. NO DEVIATIONS FROM DESIGN SHOW ON THESE DRAWINGS IS ALLOWED, WITHOUT WRITTEN APPROVAL FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT N CONTRACTOR CORRECTING THE INSTALLATION AT THEIR EXPENSE. M. ALL ITEMS NOT LISTED A6 'EXISTING. OR 'PROVIDED DY OTHERS' ARE TO BE SUPPLIED AND 146TALLED DT THE CONTRACTOR. DESIGN CRITERIA: L THE STRUCTURAL DESIGN OF THIS INSTALLATION IS IN ACCORDANCE WITH IBC 2006. 2. DESIGN LOADS: DESIGN DATA FOR TUKWILA, WA: • GROUND SNOW LOAD 25 par • BASIC WIND SPEED (3 SEC GUST) 85 mph • WIND EXPOSURE C • SEISMIC DESIGN CATEGORY 02 • MAPPED SPECTRAL ACCELERATIONS FOR SHORT PERIODS SB • 1350 9 • MAPPED SPECTRAL ACCELERATIONS FOR A 1 SECOND PERIOD SI • 0.415 9 CONCRETE NOTES: I. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI -318. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC 2006 SECTION 1905 AND ACI 301. STRENGTHS AT 25 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS. 3. TYPE OF CONSTRUCTION 28 DAY STRENGTHS W/C (Tc) RATIO A SLABS ON GRADE TOPPING SLABS CONCRETE PIERS 3000 PSI 5 .45 MINIMUM CEMENT CONTENT PER CUBIC YARD 5 1/2 SACK B. ALL STRUCTURAL CONCRETE 4000 PSI 5.45 6 I/t SACKS C. FOUNDATIONS 3,000 PSI S .45 5 I/J SACKS CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II UNO. 4. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. 5. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C454, C615, C983 AND CI011. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WITH TABLES I9042J OF THE IBC 2006. 6. REINFORCING STEEL SHALL COI -FORM TO ASTM A615 (INCLUDING SUPPLEMENT SI), GRADE 60, fy60000 PSI. EXCEPTIONS: ANY BARS SPECFICALLY SO NOTED 04 THE DRAWINGS SHALL BE GRADE 40, fy40000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A106. REINFORCING COMPLYING WITH ASTM A615(61) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN ANUS. 014 ARE SUBMITTED. 1. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 35 AND 318. LAP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 5' AT SIDES AND ENDS. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A -IBS. 9. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A6E, GRADE 60, (5.60000 PSI. 10. NO BARS PARTIALLY EMBEDDED N HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECFICALLY 50 DETAILED OR APPROVED BY THE CONSULTANT. IL CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: • FOOTINGS AND OTHER UNFORMED 3• SURFACES, EARTH FACE • FORMED SURFACES EXPOSED 06 BARS OR LARGER) 2" TO EARTH OR WEATHER 05 BARS OR SMALLER) 11/2" • SLABS AND WALLS (INTERIOR FACE) U. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. 13. ANCHOR BOLTS TO CONFORM TO ASTM A301. 3/4' 14. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED N STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON WHICH IT IS PLACED (3000 PSI MINIMUM). STRUCTURAL STEEL NOTES: I. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 1. STRUCTURAL STEEL DESIGN, FABRICATION, PAINTING AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL BE BASED ON THE A.I.SO. "SPECIFICATION FOR THE DESIGN, FABRICATION. AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE WITH CHAPTER IT OF THE INC 2006, BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: TYPE OF MEMBER A, PLATES, SHAPES. ANGLES, AND RODS B. SPECIAL SHAPES AND PLATES C. PIPE COLUMNS D. STRUCTURAL TUBING E. ANCHOR BOLTS F. CONNECTION BOLTS ASTM A36, Fy 36 KSI ASTM A512. Fy 50 K61 ASTM A53, Fy 35 KSI ASTM A500, Fy 46 KSI ASTM A301 ASTM A325 TWIST -OFF -TYPE 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER AI23/A123M-00. 5. ALL WELDING SHALL BE IN CONFORMANCE WITH A.ISO. AND AWS STANDARDS AND SHALL BE PERr-OR"ED BY WABO. CERTIFIED WELDERS USING 810 XX ELECTRODES. ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDRIVSFN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E10 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS N REINFORCING STEEL 15 NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. 6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE. AND GAGE SHOWN ON THE PLANS. PROVIDE MINMUI SECTION PROPERTIES INDICATED. ALL COLD -FORTED STEEL FRAMING SHALL CONFORM TO THE AISS. "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS." 1. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS DIA) AND SHALL NAVE A MINIMUM OF TWO BOLLS UNLESS NOTED OTHERWISE. ALL ASSEMBLY ARE TO BE TIGHTENED IN ACCORDANCE WITH "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A430"., JUNE 30, 2004. FOR BEARING -TYPE CONNECTIONS, AS A MINIMUM, THE BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED IN THE ABOVE REFERENCED CODE. 8. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A301 BOLTS UNLESS NOTED OTHERWISE. 9. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE 10. TOUCH UP ALL FIELD DRILLING AND WELDING WITH 2 COATS OF GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL. SPECIAL INSPECTIONS: SPECIAL INSPECTION6 N ACCORDANCE WTH SECTION 1104 OP THE IBC 2006. SOILS/GEOTECFANICAL: ❑ SHORING INSTALLATION AND MONITORING ❑ OBSERVE AND MONITOR EXCAVATION ❑ VERIFY SOIL BEARSG PSF BEARING ❑ SUBSURFACE DRAINAGE PLACEMENT O VERIFY FILL MATERIAL AND COMPACTION 0 VERIFY CONDITIONS AS ANTICIPATED O PILE PLACEMENT (AUGER CAST/DRIVEN PILE) ❑ OTHER REINFORCED CONCRETE: 0 REINFORCING STEEL AND CONCRETE PLACEMENT 0 PRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION ❑ BATCHPLANT INSPECTION ❑ SHOTCRETE ❑ GROUTING ❑ OTHER STRUCTURAL STEEL ❑ FABRICATION AND SHOP WELDS 0 ERECTION AND FIELD WELDS AND BOLTING ❑ OTHER STRUCTURAL ALUIINIM: 0 FABRICATION AND SHOP WELDS 0 ERECTION. FIELD WELDS AND BOLTING ❑ OTHER STRUCTURAL MASONARY: 0 CONTINUOUS 0 PERIODIC OTHER ANCHORING TO CONCRETE: 0 BOLTS INSTALLED 51 CONCRETE 0 POST -INSTALLATION ADHESIVE ANCHORS 0 POST -INSTALLATION MECHANICAL ANCHORS RE*LCOM ENGINEERING 401 - 11608 - 66TH AVE SURREY, BC V35 1X1, CANADA TEL: (604) 514-6432 FAX: (6041 514-6431 TOLL FREE: 1-511-345-4045 EMAIL: nall•trkengcom WEB: www.trken com PROJECT NO, 0630-020 DRAIN SY. 010055D eY. Fri CAD FILE: 0630-020AI SUBMITTALS OCT 5/01 GENERATOR REv5ION JUNE 23/01 GENERAL RE14I5.0 0 MAY 14/01 I56IIED FOR 8PJCONBT. APR 20/01 ISSUED FOR REVIEW THE INFORMATION CONTAINED N THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. AAE SEAL SITE SEA BRISCO 18100 ORILLIA FRO 6 TUKWILA, WA SHEET TITLE SPECIFICATIONS SHEET NUMBER A-1 / I / /4 // / EXISTING BUILDING FOUND 4"x4" RIGHT OF WAY MONUMENT ABANDONED . TELEPHONE POLE EXISTING 51GN EXISTING LIGHT POLE EXISTING DIRT ACCESS ROAD EXISTING POUTER POLE 10'-0" EASE EXISTING CNAINLINK FENCE EASEM III APPROXIMATE LOCATION OF EXISTING SCALE EXISTING TRANSFER I STATION TOLL BOOTH EXISTING POWER POLE OENLARGED SITE PLAN 0 1020 50 GUY POLE CONNECTING TO EXISTING POWER POLE TO THE WEST TAX LOT NO. 352304-901S EXISTING TREE LINE S m TAX LOT NO. 352304-9031 W Q W 4 TREE NORTH ARROW 5HOUN ON TI -US DRAWING IS APPROXIMATE ONLY AND MUST BE VERIFIED BY CONTRACTOR i--- IS 81'56'02" EI I ii 352304-9031 j I i 1 ---1 TAX LOT NO. .Ebh% I 352304-9034 / I ` �, I in. \ \ I 1 ;II \ 1 I co 1 1 \ J 1 iI zl \„, 1 3_ 3i I T+\e v , tea•” \`G II v5i I i TAX LOT NO. T SEE ENLARGED I 352304-9051 / %/ NOTES: I. SITE PLAN INFORMATION WAS OBTAINED FROM AN EXISTING DRAWING PROVIDED BY OTHERS. THIS DRAWING DOES NOT REPRESENT A SURVEY. ALL DIMENSIONS TO PROPERTY LINES ARE APPROXIMATE ONLY. LEGAL DESCRIPTION: BEGINNING AT THE WEST 1/4 CORNER OF SECTION 35, TOUNSHIP 23 NORTH, RANGE 4 EAST, WM.; THENCE SOUTH 51'56' EAST 960 FEET; THENCE SOUTH 53'24'59" LEST 12151 FEET; THENCE SOUTH 38'42'02" EAST 114463 FEET; THENCE SOUTH 4'04' WEST 490 FEET; THENCE NORTH 81'51' WEST 123831 FEET; THENCE NORTH 5'44'13" EAST 181511 FEET TO BEGINNING; EXCEPT ROADS; EXCEPT STATE HIGHWAY SITUATE M THE COUNTY OF KING, STATE OF WASHINGTON. PER TITLE REPORT NO. N311315 ISSUED BY FIDELITY NATIONAL TITLE COMPANY OF WA511MGTON. 2 W UTILITY EASEMENT F\41. I I FOUND 4"x4" RIGHT OF WAY MONUMENT _ I iI II I1 , I I hLL 1 II 4I I1 i I 1, / I 1 I; \\ TAX LOT NO. •x352304-9048 TAX LOT NO. 1 352304-031 w1 I O m Z fil eee1xp Z �IW 09 E QIm Xn O 'II 01Y I I_ m ZJ I / 34 3 T 123831' '- i��TAX LOT NO. 352304-9018 TAX LOT NO. 352304-9068 TAX LOT NO. 352304-9016 FOUND MONUMENT AT INTERSECTION OFTAX LOT NO. /5 188TH ST AND THE 352304-9045 OFF/ON RAMPS OF I-5 FOUND MONUMENT AT THE SOUTHWEST SECTION CORNER OF SEC. 35, TSP. 23 N, RNC. 4 E. WM. SITE PLAN 0 80 ISO 240 TAX LOT NO. I 35230479015 °5 I tiailiMwireless REX►LCOM ,ENGINEERING .201 - 11688 - 66TH AVE SURREY, BC V35 TXI, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I-811-345-4045 EMAIL: mall•trken9row UEB: wuw.trkengcan PROJECT NO. 0630-010 DRAWN 81, GM ct£QCED Or FM. CAD FILE: 0630-01042 SUBMITTALS 2 001 11/01 GENERATOR REVISION ANE 25/01 GENERAL REVISIONS 0 MAY H/01 INSIED FOR BP/CONLST. A APR 20/01 136E0 FOR REVIEW THE INFORMATION CONTAINED N THIS SET OF DOOJIENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN TWAT WHICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. ANE SEAL SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SHEET TITLE SITE PLAN SHEET NUMBER A-2 TRUE NORTH ARROW SHOWN ON THIS DRAWING 15 APPROXIMATE ONLY AND MUST BE VERIFIED BY CONTRACTOR EXISTING CHAINLINK FENCE C/B PRIVACY SLATS 14' -Il' EXISTING GRASS -AREA EXISTING VERIZON WIRELESS EQUIPMENT CABINET, TTP. EXISTING ELECTRICAL CABINET EXISTING VERIZON WIRELESS RAISED PLATFORM CAU EQUIPMENT CABINETS VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR „ REFER TO A-5 FOR DETAILS EXISTING VERIZON WIRELESS ELECTRICAL H -FRAME EXISTING VERIZON WIRELESS SERVICE METER REMOVE THIS PORTION OF EXISTING EQUIPMENT FRAME GRATING TO FACILITATE INSTALLATION OF EMERGENCY GENERATOR REFER TO 5-I FOR DETAILS RELOCATE EXISTING BEAM AS SI -TOWN FASTEN GRATING TO BEAM AS PER MANUFACTURES RECOMMENDATIONS EXISTING VERIZON WIRELESS WAVEGUIDE BRIDGE EXISTING RIDGE OF BANK EXISTING MONOPOLE EXISTING MONOPOLE FOUNDATION EXISTING ELECTRICAL H -FRAME CN) ICE BRIDGE EXISTING TELCO PEDESTAL EXISTING T -MOBILE WAVEGUIDE BRIDGE EXISTING WOOD UTILITY POLE EXISTING EQUIPMENT PAD G/W EQUIPMENT EXISTING GRASS AREA EXISTING GUY WIRE EXISTING T -MOBILE EQUIPMENT PAD CAW EQUIPMENT 0 COMPOUND LAYOUT I 2 5 I I NOTES: I. CONTRACTOR'S WOW SHALL COMPLY WITH ALL APPLICABLE NATIONAL. STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS N EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. C t rQ/. wireless REILCOM ENGINEERING F201 - 11688 - 66TH AVE SURREY, BC VES TXI, CANADA TEL: (604) 514-6432 FAX, (604) 514-6431 TOLL FREE: I-011-345-4045 EMAIL: mall.trkengcom I1EB: www.trkangcom PROJECT NO: 0630-020 DRAW eY: GH CHECKED 5T: Fit GAD FILE: 0630-020A3 SUBMITTALS OCT 0101 GE8ERATOR REVISION J11E 25/01 GENERAL RE VISIONS e MAT 4/el IS91ED FOR EP/CONST. A APR 2P/el ISSUED FOR REVIEW THE IWORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY By NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT IWICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. ASE SEAL SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SHEET TITLE COMPOUND LAYOUT SHEET NUMBER A-3 EXISTING WOOD UTILITY POLE EXISTING OVERHEAD UTILITY LINE EXISTING GUY WIRE EXISTING LIGHTNING ROD T.O. EXISTING MONOPOLE/ VERIZON WIRELESS ANTENNA TIP HEIGHT 60'-0"i A.G.L. NOTES: I. ELEVATION IS DIAGRAMMATIC ONLY. 2. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES FWD STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN. EXISTING VERIZON WIRELESS ANTENNA PLATFORM CNB ANTENNAS EXISTING T -MOBILE RAD CENTER 4l' -611t AGL. EXISTING T -MOBILE ANTENNA PLATFORM CNB ANTENNAS EXISTING WOOD UTILITY POLE EXISTING OVERHEAD UTILITY LINE it EXISTING ANTENNA PLATFORM EXISTING 60'-0" MONOPOLE EXISTING VERIZON WIRELESS ANTENNA WAVEGUIDE BRIDGE VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR REFER TO 5-1FOR DETAILS EXISTING T -MOBILE WAVEGUIDE BRIDGE EXISTING TELCO PEDESTAL EXISTING CHAINLINK FENCE CAI PRIVACY SLATS EXISTING T -MOBILE EQUIPMENT PAD CNB EQUIPMENT EXISTING VERIZON WIRELESS EQUIPMENT CABINET EXISTING GUY WIRE EXISTING T -MOBILE WAVEGUIDE BRIDGE EXISTING CNAINLINK FENCE CNI PRIVACY SLATS EXISTING ELECTRICAL I4 -FRAME CNB ICE BRIDGE DEA5T ELEVATION 0 2 4 EX STING VERIZON WIRELESS EQUIPMENT PAD EX STING VERIZON WIRELESS ELECTRICAL H -FRAME EXISTING MONOPOLE FOUNDATION CDLUEST ELEVATION 0 2 4 FT-- I . '01 Cfer'c1nwire&eSS RE*LCOM • ENGINEERING 401 - 1158$ - 66T1-1 AVE SURREY, BC V3S TXI, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I-811-345-4045 EMAIL: RAII0trke.$OOR WEB: 20454rkang400 PROJECT NO: 0630-020 DRAW( BY: GH. 442004ED BY. FM. 0.40 FILE: 0630-020A4 SUBMITTALS 1 OCT 12/01 GENERATOR REVISION JUNE 15/01 GENERAL REVISIONS MAY M/01 ISSUED FOR BP/CONST. A APR 20/01 ISSUED FOR REVIEW THE IFFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE ANY USE OR DISCLOSURE OTFER THAN THAT IWICH RELATES TO TI -E CLIENT NAMED IS STRICTLY PROHIBITED. 425 SEAL SITE SEA BRISCO 15100 ORILLIA RD 5 TUKWILA, WA SFEET TITLE EAST AND WEST ELEVATIONS SHEET NUMBER A-4 EXISTING T -MOBILE EQUIPMENT CABINET EXISTING ELECTRICAL I -I -FRAME CNl ICE BRIDGE C... e 1- 01111111111111111111111111111111' n • 1! ( N EXISTING LIGHTNING ROD TA. EXISTING MONOPOLE/ VERIZON WIRELESS ANTENNA TIP HEIGHT 60'-o"± A. L. EXISTING VERIZON WIRELESS ANTENNA PLATFORM C W ANTENNAS EXISTING T -MOBILE RAD CENTER 41'-6"t ACL. EXISTING T -MOBILE ANTENNA PLATFORM CAU ANTENNAS EXISTING ANTENNA PLATFORM EXISTING 60-0" MONOPOLE EXISTING WOOD UTILITY POLE EXISTING VERIZON WIRELESS EQUIPMENT CABINET CDNORTI-1 ELEVATION 0 2 4 8 I EXISTING VERIZON WIRELESS ELECTRICAL I -I -FRAME NOTES: I. ELEVATION IS DIAGRAMMATIC ONLY. 2. CONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL. STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL GOVERN THE DESIGN, EXISTING LIGHTNING ROD TA. EXISTING MONOPOLE/ VERIZON WIRELESS ANTENNA TIP HEIGHT T1fint t1I,Iltil 1 SII II . O UI 60'-0"= A.G.L. EXISTING VERIZON WIRELESS ANTENNA ALATEORFM CO ANTENNAS EXISTING T -MOBILE RAD CENTER 41'-6"t EXISTING T -MOBILE ANTENNA PLATFORM C/U) ANTENNAS EXISTING ANTENNA PLATFORM EXISTING 60'-0" MONOPOLE EXISTING WOOD UTILITY POLE VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR REFER TO S-1 FOR DETAILS EXISTING VERIZON WIRELESS EQUIPMENT CABINET EXISTING ELECTRICAL H -FRAME C/U) ICE BRIDGE O SOUTH ELEVATION 0 2 4 8 terwireless REI►LCOM ..--ENGINEERING 401 - 11689 - 66TH AVE SURREY, BC V39 -1XI, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FTSE: 1-811-345-4045 EMAIL: mailatrkangcom WEB: Wuw.trkangcom PROJECT NO. 0630-020 DRAN BT: GFL CLEMED Et. FM. CAD FILE. 0630-020A4A SUBMITTALS 1 OCT 11/01 GENERATOR REVISION JItE 25/01 GENERAL REVISIONS MAY LU01 ISSUED FOR BP/CONST. A APR 20/01 (SEED FOR REVIEW THE SPOS'IATION CONTAUED IN THIS SET OF DOOMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT IWICH RELATES TO TIE CLIENT NAMED IS STRICTLY PROHIBITED. ANE SEAL SITE SEA BRISCO 18100 ORILLIA RD S TUKWILA, WA SLEET TITLE NORTH AND SOUTH ELEVATIONS SLEET NUMBER A -4A \-•*".:-.......°------ ve wireless 4I 3 Nip- 21 1 R E * L C O M R WI 51055 ZONE REV DESCRIPTION DATE APPROVED 03 A RELOOATEDPORTS 08D 13MA1135 OF C3 A ADDED PORTS K S L 13 MATOS OF 03 B RELOCATED PORTS K£1. L 13 MATTE OF EDC3 C RELOCATED PORTS K&L NI MA-TOS OF ID C3 D OHANDEDPOR TSO 13M41DE OF 03 5 REMOVED PORTS DANDJ WOUNDS OF 15 50 4..- — - -;- 9.50 -� $ 1 1 1 .-ENGINEERING �t01-11688-66TH AVE SURREY, BC 514-6432, CANADA TEL (604) TOLL FREE: 8116431 345-4045 coo t "9� j y { A-.50' RETURN }I }I *I B- PICKUP _ r--- 1 16.00 22.00 20.38 25.J I E ®D® 6 I D-2.00' GUAGE 4.00 I 4.25 ¢ILeUA } E-2.�' VENT 7.25 28.BT F- 2.00 VENT e I I 6A 1 I 9.00 H - 1.25' SENSOR K- ,i,63 I i .75' L. . T5" PRO.IECT NDS 0630-020 X, la L c DR! WJ BY, GH. REMOVABLE PLATE FUEL HEATER LOOP HOLD ALL PORT FITTINGS BELOW THIS SURFACE 14.50 27.00 —Um X1111— 3.00 -.0— 1"j 273 0 H BAFFLE CIELKED BY, FM CAD RLE: 0630-020A5 SUSMITTAL5 52 GALLON ULUSTED r----- ---1— r DOUBLE WALL SUB BASE TANK ¢I 20.00 1 T 50 I I I L J J 2 OCT I2/61 GENERATOR REVBION I .0.6 25/01 GENERAL REVISIONS 0 MAY H/Cl 163IED FOR BP/CONST. A APR 20/01 ISSD FOR REVIEW ISSUED B___s�J 1.00 29.00 1.00 1.00 3.00 1.00 B THE RFORIATIDN CONTAINED N THIS SET OF DOCIT'ENTS IS PROPRIETARY BY NATURE. ANY USE OR DILALOSU RELATES TO OTHER THAN THAT 111-11014 RELATES THE CLIENT NAMED IS STRICTLY PROHIBITED. 34.00 CAPACITY 52.67 GALLON S ASE SEAL A VICTORY 1115 DRAINING OPSORGIN4®EYAND 19TH E EXCLITEIJE P RJ PETR YOF VICTORY INOUSTRUIL PRO DUCTS NC. ITS FURNRHEO FOR CUSTOMER ONLY NDS NORLIOTO MICE THE CO N3lRICCTON CR TO RJR NISH THIS INFO MATO 5TO OTHERS. A.INFORMATION SITE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SUB BASE TANK INDUSTRIAL PRODUCTS MOtotd•OHD N.e7..E., LAYOUT-TANK UNDERWRITERS LABORATORIES INC. COMPLETE UNIT EST INEIGHT USTED (UL142) FILE; MH17934 WEr=908 LB [ 412 KG] COMPUES NTH NFPA NO. 30 ALL DIMENSIONS ARE IN INCHES. DRAWN 136 GE PORTER S12£ C 666.. SEEA*DVE E60 ND. 8471742 REV E 61EETTITLE GENERATOR FUEL TANK DRY= 511 LB[ 232 KO I FLAMMABLE AND COMBUSTIBLE LJQUIDS COM UNLESS OTHERIMSESPECIFIED. DA 11 MAY05 SCALE; 1;16 REF PF 7479 I SHEET. 1 OF 1 4 I 3 46. 2 1 1 SIERT TENHER A-5 ti ti RELOCATE EXISTING BEAM AS SHOWN. ANCHOR BEAM TO EXISTING CONCRETE PAID WITH 3/8" HILT KWIK BOLT III. EMBEDED 3", TYP. `4 FASTEN GRATING TO RELOCATED BEAM USING FISHER LUDLOW HOLD DOWN "W" BRACKETS, OR APPROVED EQUAL °GENERATOR LAYOUT 0 12 I � I 4'-4" EXISTING VERIZON WIRELESS RAISED PLATFORM SUPPORT BEAM, TYP. EXISTING VERIZON WIRELESS RAISED PLATFORM C/W EQUIPMENT CABINETS VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR REMOVE THIS PORTION OF EXISTING EQUIPMENT FRAME GRATING TO FACILITATE INSTALLATION OF EMERGENCY GENERATOR AS SHOWN. TOUCH UP CUT ENDS OF GRATING WITH 2 COATS OF GALVACON ea OGENERATOR PLINTH LAYOUT O 2 EDGE OF EXISTING CONCRETE PAD 2" SIDE AIR SPACE REQUIRED ®GENERATOR DETAILS 0 6" NOTES: I. REFER TO A -I FOR SPECIFICATIONS. 2. REFER TO A-8 FOR DR£1481CN8. - 0- 0 - CABINET STYLE DC 81ODIESEL GENERATOR 9 IV - 1/2" DIA. HILTI KWIK BOLT III CONCRETE ANCHOR EMBEDED 4", TYP. OF 6 OGENERATOR BOLT DOU1N LAYOUT O 2 CABINET STYLE BIODIESEL DC GENERATOR °GENERATOR ISOMETRIC N.T.S. ven wireless REA►LCOM ENGINEERING 20I - 11688 - 66T1-1 AVE SURREY. BC V39 1X1, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE, I-811-345-4045 EMAIL: na114trkeegcom ¢E8: www.vlurgcon PROJECT No. 0630-020 DRAIN BY, GH CHECKED D, F.M. CAD FILE. 0630-02051 SUBMITTALS OCT 12/01 GE,ERAT e: REVISION .NE 25/01 GENERAL REVISIONS 0 MAY 14/01 ISSUED FOR BP./CONST. A AMR 20/01 158.E0 FOR REVIEW Toff INFORMATION CONT4RED IN THIS SET OF 00312 ENT9 19 PROPRIETARY BY NATURE. MY 119E OR DISCLOSURE OTWER THAN THAT 91 -)ICH RELATE5 TO 7141 CLIENT NAMED 15 STRICTLY PROHIBITED. AHE 5843 61TE SEA BRISCO 18100 ORILLIA RD 5 TUKWILA, WA SWEET TITLE STRUCTURAL DETAILS SWEET NUMBER S-1 EXISTING METER EXISTING CONDUCTORS EXISTING 200A, 2 POLE MAIN DISCONNECT C EXISTING CONDUCTORS EXISTING POWER CABINET EXISTING ELECTRICAL PANEL C �J 20A, IP n 20.4, IP n EXISITNG GENERATOR RECEPTACLE 2-'12 T141 -IN (SIGNAL), i- 2-012 TI -11 -IN (AUXILIARIES) PLUS 012 GROUND IN I" RMC CABINET STYLE BIODIESEL f DC GENERATOR 500 2 RUNS OF 250 MCM TI -II -IN IN 2" RMC EXISTING POWER/BATTERY/ CABINET DESIGN WAS BASED ON 24VDC GENERATOR. CONTRACTOR TO CONFIRM WITH CONSTRUCTION MANAGER IF SITE WILL BE 24V OR 48v DC PRIOR TO CONSTRUCTION SINGLE LINE DIAGRAM ELECTRICAL SPECIFICATION I. ALL ELECTRICAL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. 2. COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE. THE REQUIREMENTS OF ALL APPLICABLE MUNICIPAL AND STATE CODES AND REGULATIONS. AND UTILITY GUIDELINES. 3. PERFORM ALL VERIFICATION. OBSERVATIONS, TESTING AND EXAMINATION OF WORK PRIOR TO THE ORDERING OF ELECTRICAL EQUIPMENT AND THE ACTUAL. CONSTRUCTION. ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE CONSTRUCTION MANAGER LISTING ALL MALFUNCTIONS, FAULTY EQUIPMENT AND DISCREPANCIES. 4. UNDERGROUND CONDUIT SHALL BE RIGID POLYVINYL CHLORIDE CONDUIT: SCHEDULE 40, TYPE I, CONFORMING TO UL ARTICLE 651: WESTERN PLASTICS OR CARBON MANUFACTURER COUPLINGS SHALL BE SLIP-ON SOLVENT SEALED T PIPE: SOLVENT, WESTERN TYPE COMPATIBLE WITH PVC DUCT, ALL BENDS SHALL BE 30" MINIMUM RADIUS. 5. ALL WIRING SHALL BE STRANDED COfTLR WITH MINIMUM 600V INSULATION (UNLESS OTHERWISE NOTED). 6. NEUTRAL SHALL BE COLOR CODED, INSULATION SHALL BE CROSS-LINKED POLYETHYLENE. 1. CONTRACTOR TO CONTACT ALL UTILITIES FOR LOCATION OF UNDERGROUND SERVICES. SERVICE LOCATIONS TO BE CONFIRMED PRIOR TO CONSTRUCTION. S. THE CONTRACTOR IS RESPONSIBLE FOR ALL PERMITTING, FILING, AND FEES IN CONJUNCTION WITH THE PROJECT. B THE CONTRACTOR SHALL SCHEDULE ALL NECESSARY INSPECTIONS WITH THE PROPER AUTHORITIES AND INFORM VERIZON 24 -HOURS IN ADVANCE. ALL TICKETS AND INSPECTION VERIFICATIONS WILL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE WITHIN 24 -HOURS AFTER THE INSPECTION HAS TAKEN PLACE. 10. ALL EQUIPMENT, WIRING, AND MATERIALS FEST HAVE A UL LABEL. U. ALL WORK SHALL BE DONE BY QUALIFIED AND EXPERIENCED JOURNEYMEN AND FEW -OWED IN A WOR :IANNLIKE MANNER AND SHALL PROCEED IN AN ORDERLY MANNER SO A5 NOT TO .OLD UP THE PROGRESS OF THE PROJECT. 12. THOROUGHLY TEST ALL LINES, FEEDERS, EQUIPMENT, AND DEVICES WITH MAXIMUM LOADS TO ASSURE PROPER OPERATION. 13. CONDUCTOR LENGTHS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION WITHOUT SPLICES. K . PROVIDE PULL BOXES WHERE SHOWN AND/OR WHERE REQUIRED BY CODES AND/OR UTILITY COMPANIES. B. ALL CONDUIT ROUGH IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. CONTRACTOR SHALL VERIFY ALL LOCATIONS. 16. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J -BOXES, EQUIPMENT BOXES, AND CABINETS WITH APPROVED PLASTIC TAGS. Il. ALL BREAKERS IN PANEL BOXES SHALL BE IDENTIFIED WITH TYPE WRITTEN LABELS NEATLY PLACED ALONG SIDE OF THE BREAKER EQUIPMENT SPECIFICATION L DUPONT MATERIALS INC. CARNET STYLE DC GENERATOR GENERATOR MODEL: DDC -12-24, 125W, 24VDC, 500 AMPS EXPIRES 09/11/ .9,o0S tFerilMwireless REX►LCOM ENGINEERING "201 - 116es - 66TH AVE SURREY, BC V3S 9X1, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I -S11-345-4045 EMAIL: neiHtrkengcom WEB: uFmltrkerlocon PROJECT NO. 0630-020 DRAIN PY, GH. CHEOCED ST. SLI. CAD FILE, 0630-020EI SUBMITTALS OCT Orel GETERATOR REVISION JUNE 25/01 GENERAL REVISIONS 0 MAY 4/01 15SUED FOR 5PJCO IST. A APR 20/01 ISSIED FOR REVIEW THE INFORMATION CONTAINED N THIS SET OF DOOUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WITCH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. A.E SEAL SEA BRISCO 18100 ORILLIA RD S TUKWILA, WA SHEET TITLE SINGLE LINE DIAGRAM SHEET NJIMBER E-1 TRUE NORTH ARROW SHOIIN ON TI -115 DRAWING IS APPROXIMATE ONLY AND MAST BE VERIFIED BY CONTRACTOR EXISTING VERIZON WIRELESS EQUIPMENT CABINETS, TYP. EXISTING POWER CABINET EXISTING ELECTRICAL PANEL INSIDE CABINET 2-.12 TI41-IN (SIGNAL), 2-92 THHN (AUXILIARIES) PLUS ell GROUND IN I" RMC EXISTING SERVICE METER 2 RUNS OF 250 MCM TI-IHN IN 2" RMC TO EXISTING POWER/BATTERY CABINET. TERMINATION LOCATION T.B.D. EXISTING MONOPOLE VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR TERMINATE AT GENERATOR IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS FASTEN CONDUIT TO CONCRETE PAD AT 36" 0/C CD COMPOUND ELECTRICAL LAYOUT 0 I 2 3 I . NOTES: I. OBTAIN LOCATES PRIOR TO ANY EXCAVATION. REFER TO SITE WORK GENERAL NOTES ON DRAWING A-3. 2. CONTRACTOR To VERFY AVAILABILITY OF EPARE CIRCUIT BREAKERS PRIOR TO CON$TRUCTICK TRIC ENGINEERING DID NOT HAVE ACCESS TO INTERIOR OF ELECTRICAL CARNET DURING SITE WALK E)W509„0D2 1 Bewireless RE*LCOM "201 - 11688 - 6611-1 AVE SURREY, BC V3S 1X1, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I -S11-345-4045 EMAIL, nellItrkergiccn IIEB wuu.lrkeng.con PROJECT NO. 0630-020 DRAIN BY. GK OEOCEP BY. CAD FILE: 0630-020E2 SUBMITTALS OCT 0/01 GENERATOR REVI5104 AAE 25/01 GENERAL REVI5045 0 HAY 14/01 150E0 FOR 15P/CO15T. A APR 20/01 150E0 FOR RENEW THE PFORTIATION CONTAINED IN THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANT USE OR DISCLOSURE OTHER THAN THAT 1114110H RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. AlE SEAL SITE SEA BRISCO 15100 ORILLIA RD S TUKWILA, WA SHEET TITLE ELECTRICAL LAYOUT SHEET N216ER E-2 TRUE NORTH ARROW SHOU.N ON THIS DRAWING IS APPROXIMATE ONLY AND MUST BE VERIFIED BY CONTRACTOR EXISTING ELECTRICAL 7 -CABINET 1, J EXISTING VERIZON WIRELESS EQUIPMENT CABINET, TYP. (EXISTING GRASS AREA VERIZON WIRELESS CABINET STYLE BIODIESEL DC GENERATOR "r-- APPROXIMATE LOCATION OF � " EXISTING GROUND RING EXISTING MONOPOLE DCOMP0UND GROUNDING LAYOUT 2 3 CADWELD 2 SOLID BARE TINNED COFFER TO GENERATOR FRAME GROUNDING SPECIFICATION I. GROUNDING SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND VERIZON WIRELESS STANDARDS. 2. MINIMUM BENDING RADIUS FOR GROUND CONDUCTOR IS 8". 3. NO SPLICES PERMITTED IN GROUND CONDUCTORS. 4. INTERCONNECT ANTENNA GROUND LUG TO •2 SOLID BARE TINNED COPPER (IF APPLICABLE). 5. ALL GROUNDING CONNECTORS TO BE CLEAN AND FREE OF PAINT AT THEIR MATING SURFACES AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. USE PENETROX OR EQUIVALENT ANTIOXIDANT GREASE. 6. ALL GROUND BAR CONNECTIONS ARE TO BE 2 HOLE LUG 5/8" BOLT CONNECTOR COMPRESSION TYPE. STACKED CONNECTIONS ARE NOT ACCEPTABLE. BACK TO BACK CONNECTIONS ON OPPOSITE SIDES OF THE GROUND BAR WILL BE PERMITTED. 1. ENSURE ALL MECHANICAL CONNECTORS ARE TORQUED TO THE MANUFACTURER'S SPECIFIED VALUES. B. MULTIPLE BONDS ON GROUND RODS TO BE SEPARATED BY AT LEAST 6". 5. MAXIM -51 RESISTANCE OF THE COMPLETED GROUND SYSTEM SHALL NOT EXCEED A RESISTANCE OF 5 OHMS TO EARTH. 10. GROUND WIRES SHALL NOT BE INSTALLED THROUGH HOLES IN ANY METAL OBJECTS OR SUPPORTS TO PRECLUDE ESTABLISHING A 'CHOKE" POINT. II. FERROUS METAL CLIPS WHICH COMPLETELY SURROUND THE GROUND WIRE SHALL NOT BE USED. METAL CLIPS THAT DO NOT COMPLETELY SURROUND THE GROUND WIRE OR PLASTIC CLIPS ARE ACCEPTABLE. 12. GROUND BARS SHALL NOT BE FIELD MODIFIED. 13. VERIFY ALL GROUND CONNECTIONS WITH SHELTER ON SITE. 14. ALL EXTERIOR GROUND BARS TO EE TINNED COPPER LEGEND GROUND ROD WITH INSPECTION PORT ® GROUND ROD ▪ CADWELD ® 2 HOLE LUG CONNECTION BURNDY TYPE YGHC-C COMPRESSION CONNECTOR JEXPIRES 09/11/ . 0"), IfeirgLx_NEwireless RE*►LCOM `ENGINEERING X201 - 11688 - 66TH AVE SURREY, BC V35 1X1, CANADA TEL: (604) 514-6432 FAX: (604) 514-6431 TOLL FREE: I-811-345-4045 EMAIL: mgII•tlkgng.pom WEB: www.trksng.00m PROJECT NO, 0630-020 DRAIN BY, GM CHECKED BY, SAL CAD FILE, 0630-020E3 SUBMITTALS 2 OCT 12/01 GEI.ERATOR REVISION NIDE 25/01 GENERAL REVISIONS 0 HAT 14/01 ISSUED FOR BP/CONST. APR 20/01 ISSUED FOR RENEW THE INFORMATION CONTAINED N THIS SET OF DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO THE CLIENT NAMED IS STRICTLY PROHIBITED. ASE SEAL SITE SEA BRISCO 15100 ORILLIA RD S TUKWILA, WA SHEET TITLE GROUNDING DETAILS SHEET NUMBER E-3