Loading...
HomeMy WebLinkAboutST - 14805 INTERURBAN AVE S - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) I ABOVE GROUND STORAGE TANKS (AST) 14805 INTERURBAN AVE S RELATED PERMIT NUMBER(S) 210-87 1 rho C -{ �-1 z A c t 1. N N N N N C G — � y 1 A C t N •G • N 0 Q v 1 • 3 ti J t rho S. ts Qo 4 Z C Z A C 0 N " z F 1 Date: 8/21/87 Na 210-87 TUKWILA FIRE DEPARTMENT SPECIAL PERMIT BY virtue of The Provisions of the Uniform Fire Code adopted by City of Tukwila Ordinance, O'SULLIVAN CONSTRUCTION located at 14805 interurban Avenue South Business Name Business Address having made application in due form, and as the conditions, surroundings, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and this PERMIT is granted for *To install, alter, remove, abandon, place temporarily out of service or otherwise dispose of any flammable or combustible liquid tank, see Article 79 per 4.101 paragraph 18, Sec. E of the Uniform Fire Code* This PERMIT is issued and accepted on condition that alf Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT VALID FOR -August 24, 1987 thru September 24, 1987 - This permit does not take the place of any license required by law and is not transfer- able. Any change in the use or occupancy of premises shall require a new permit. THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE T.F.D./F.P. *2 4 //2 C' • # .X/l )7_7/s TUKWILA FIRE DEPARTMENT Special Permit Application PER UNIFORM FIRE CODE, SECTION 4.101, SPECIAL PERMIT(S) ARE REQUIRED FOR ANY PERSON, FIRM OR CORPORATION TO USE A BUILDING OR PREMISES OR ENGAGE IN ANY ACTIVITIES FOR ANY OF THE FOLLOWING PURPOSES LISTED BELOW: To handle, store or use flammable/combustible liquids.: (79.103) _ To store, transport or handle hazardous chemicals. (80.102) To install or maintain any liquefied petroleum gas (LPG) container of more than 120 gallons water capacity. (82.102) To use any structure as a place of business for repairing motor vehicles. (29.102) To operate a place of assembly - 50 people or more. (25.101) To conduct welding and/or cutting operations. (49.101) To store, handle or use more than 2500 cubic feet of flammable or 6000 cubic feet of non-flammable compressed gas. (74.103) To operate a spraying or dipping operation utilizing flammable or combustible liquids. (45.102) To produce, store or handle cryogenic fluids. (75.103) To use a covered mall for display booths, etc. (35.102) To operate an industrial baking or drying oven. (62.102) Other "rail // / rrto./4 / ( ) APPLICATION IS HEREBY MADE BY THE UNDERSIGNED FOR A PERMIT TO.(USE, INSTALL, CONDUCT) IN OR ON THE FOLLOWING PREMISES: Business Name: Qr S•J I IV6N (V.N5112✓Cf O/r1 j Address: 14 / ) 1/,J (0 \C-1L(wt_W"), S A4761 THE FOLLOWING MATERIALS, PROCESSES OR OPERATIONS (Describe briefly what is to be done and the hazardous materials that are involved in the operations in the space below.) JZ) 1 TKCAN/ -A., 1S,vi OV_ i 015 you 5 4 - u(,/ c ( i74N\c-? 1 a-800°Gefrc BEFORE A PERMIT MAY BE ISSUED, THE FIRE DEPARTMENT WILL INSPECT AND APPROVE THE RECEPTACLES, VEHICLES, BUILDINGS, DEVICES PREMISES, STORAGE SPACES OR AREAS TO BE USED, ND,,y APPLICATION MUST BE RETURNED WITH YOUR CHECK IN THE AMOUNT OF $ `�, TO THE TUKWILA FIRE DEPARTMENT, 444 ANDOVER PARK EAST, TUKWILA, WASHINGTON, 98188. WP:SPECIAL.PMT T.F.D. Form F.P. 6 RECEIPT # TUKWILA FIRErDEPARTMENT UNDERGROUND FUEL TANK REMOVAL PERMIT DATE RECEIVED DATE ISSUED CODE REFERENCE: 79.113 FIRM NAME: U \ SQ 1 k/AA) (_.t)'IST'1Z v (,6A) PHONE: Zea - 8 ("' FIRM ADDRESS: )i01 W - N1C(U11711ZSU/) SGy4 Z4. £,- 1� is t I JOB SITE: )4B0s INThVZJ/2f,,4N CL Cj PERSON IN CHARGE: PRS L Uv f, i i M k ,C 1A.A ✓ I 1 PHONE: E8'.5 -e3 Co CONDITIONS: 1. TANKS MAY BE REMOVED ONLY AFTER FIRE DEPARTMENT INSPECTION. 2. Two (2) 20 BC portable fire extinguishers are to be on site within 50' of the operation. 3. Rope or ribbon barricades must be provided circling 10' from the operation or be enclosed in a fenced yard. 4. "No Smoking" signs must be posted in readily visible locations. 5. No hot works allowed unless the tanks are certified gas free. A separate Fire Department Permit is re- quired for cutting and welding operations. PROCEDURES: 1. Call twenty-four (24) hours prior to removal to arrange for an appointment. 2. Tank to be completely empty of all flammable or com- bustible liquids prior to removal. 3. To ensure that the tank atmosphere has been inerted, one (1) pound of dry ice (Carbon Dioxide) per 50 gallon capacity of the tank must be inserted in the tank. (A 1,000 gallon tank would require 20 pounds of dry ice.) This should be done prior to the use of heavy equipment for excavating. a. Wait a minimum of 60 minutes for dry ice to vap- orize. Vapors should begin to show at the fill pipe at this time. b. CO2 fire extinguishers or compressed gas are not to be used for inerting purposes. This produces static electricity which may result in an explosion. See Reverse Side 4. Tanks with baffles to prevent movement of liquid (or tanks wihout baffles larger than 10,000 gal- lons) must be certified gas free by a Marine Chemist or a Petroleum Industry Safety Engineer regularly engaged in that business prior to removal. 5. After the tanks are removed, the openings should be sealed so the CO2 gas will remain in the tank during transit. In addition, tanks large enough to allow a person to enter it to do repair work should be marked on one side with spray paint "No Air - Inert Gas". By: TUKWILA FIRE DEPARTMENT 57S-it-efo-7 Inspector T.F.D. Form F.P. 31