HomeMy WebLinkAboutST - 17024 WEST VALLEY HWY - STORAGE TANKSTANKS) UNDERGROUND STORAGE TANKS (UST) I ABOVE GROUND STORAGE TANKS (AST) 17024 WEST VALLEY HWY PARCEL NUMBER(S) 2523049049 RELATED PERMIT NUMBER(S) 356-88 297-87 298-87 Date: 12/20/88 TUKWILA FIRE DEPARTMENT SPECIAL PERMIT No. 356-88 BY virtue of The Provisions of the Uniform Fire Code adopted by City of Tukwila Ordinance, STONEWAY CONCRETE Business Name located at _ 17024 West Valley Highway__ BusinessAddress having made application in due form, and as the conditions, surroundings, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and this PERMIT is granted foe *To install, alter, remove, plaeettemporarily out of service or otherwise dispose it 11 _ . - . s 11 . - tide 79 ver 4.101, paragraph 18, section E of the Uniform Fire Code* 41, This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted„shall be complied with. THIS PERMIT VALID FOR -December 20, 1988 thru December 31, 1988 This permit does not take the place of any license required by law and is not transfer- able. Any change in the use or occupancy of premises shall require a new permit. Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE T.F.D./F.P. #2 <?? h?'l1 TUKWILA FIRE DEPARTMENT UNDERGROUND FUEL TANK REMOVAL PERMIT RECEIPT # //f ? DATE RECEIVED DATE ISSUED FIRM NAME: CODE REFERENCE: 79.114 FIRM ADDRESS : r/ 7 5' ( JOB SITE: 17o L/ Wf'A 041(T LA .\ PERSON IN CHARGE 6` ' Q 4 . c Ami ALS PHONE : 7c, 7 CONDITIONS: 1. TANKS MAY BE REMOVED ONLY AFTER FIRE DEPARTMENT INSPECTION. 2. Two (2) 20 BC portable fire extinguishers are to be on site within 50' of the operation. 3. Rope or ribbon barricades must be provided circling 10' from the operation or be enclosed in a fenced yard. 4. "No Smoking" signs must be posted in readily visible locations. 5. No hot works allowed unless the tanks are certified gas free. A separate Fire Department Permit is required for cutting and welding operations. PHONE :7C Z %V? j PROCEDURES: 1. Call twenty-four (24) hours prior to removal to arrange for an appointment. 2. Remove all flammable or combustible liquids from tank and from connecting lines. 3. To ensure that the tank atmosphere has been inerted, one (1) pound of dry ice (Carbon Dioxide) per 50 gallon capacity of the tank must be inserted in the tank. (A 1,000 gallon tank would require 20 pounds of dry ice.) This should be done prior to the use of heavy equipment for excavating. a. Wait a minimum of 60 minutes for dry ice to vaporize. Vapors should begin to show at the fill pipe at this time. See Reverse Side Date: 10/16/87 TUKWILA FIRE DEPARTMENT SPECIAL PERMIT Na 297-87 298-87 BY virtue of The Provisions of the Uniform Fire Code adopted by City of Tukwila Ordinance, STONEWAY CONCRETE located at 17024 West Valley Highway Business Address Business Name having made application in due form, and as the conditions, surroundings, and arrangements are, in my opinion, such that the intent of the Ordinance can be observed, authority is hereby given and this PERMIT is granted for *To handle, store or use flammable/combustible liquids in cabinets per 79.201 79.201g of the Uniform Fira..CdP*To conduct welding and/or cuttin3 operations per 49.101 of the U.F.C.* This PERMIT is issued and accepted on condition that all Ordinance provisions now adopted, or that may hereafter be adopted, shall be complied with. THIS PERMIT VALID FOR -Eighteen Calendar Months - This permit does not take the place of any license required by law and is not transfer- able. Any change in the use or occupancy of premises shall require a new permit. Fire Marshal THIS PERMIT MUST BE POSTED ON THE PREMISES MENTIONED ABOVE .:,• ,/01 10/16/87 TUKWILA FIRE DEPARTMENT Special Permit Application X77-,7 PER UNIFORM FIRE CODE, SECTION 4.101, SPECIAL PERMIT(S) ARE REQUIRED FOR ANY PERSON, FIRM OR CORPORATION TO USE A BUILDING OR PREMISES OR ENGAGE IN ANY ACTIVITIES FOR ANY OF THE FOLLOWING PURPOSES LISTED BELOW: To handle, store or use flammable/combustible liquids. (79.103) 6 To store, transport or handle hazardous chemicals. (80.102) To install or maintain any liquefied petroleum gas (LPG) container of more than 120 gallons water capacity. (82.102) To use any structure as a place of business for repairing motor vehicles. (29.102) To operate a place of assembly - 50 people or more. (25.101) To conduct welding and/or cutting operations. (49.101) To store, handle or use more than 2500 cubic feet of flammable or 6000 cubic feet of non-flammable compressed gas. (74.103) To operate a spraying or dipping operation utilizing flammable or combustible liquids. (45.102) To produce, store or handle cryogenic fluids. (75.103) To use a covered mall for display booths, etc. (35.102) To operate an industrial baking or drying oven. (62.102) Other ( ) APPLICATION IS HEREBY MADE BY THE UNDERSIGNED FOR A PERMIT TO (USE, INSTALL, CONDUCT) IN OR ON THE FOLLOWING PREMISES: Business Name: STONEWAY CONCRETE Address: 17024 West VAllPy Hivway THE FOLLOWING MATERIALS, PROCESSES OR OPERATIONS (Describe briefly what is to be done and the hazardous materials that are involved in the operations in the space below.) en /y � `� ]�� ( »/aYG�" �; !I / &e rpYm'& .d " i e w e /oL r".r i/D r c se, / ate-, at �t.Q .:Q Gc� ✓t�vt� i�u./�60 BEFORE A PERMIT MAY BE ISSUED, THE FIRE DEPARTMENT WILL INSPECT AND APPROVE THE RECEPTACLES, VEHICLES, BUILDINGS, DEVICES PREMISES, STORAGE SPACES OR AREAS TO BE USED, AND THIS APPLICATION MUST BE RETURNED WITH YOUR CHECK IN THE AMOUNT OF $ 20.00 , TO THE TUKWILA FIRE DEPARTMENT, 444 ANDOVER PARK EAST, TUKWILA, WASHINGTON, 98188. WP:SPECIAL.PMT T.F.D. Form F.P. 6