Loading...
HomeMy WebLinkAbout23-061 - Structural Dynamics - City Hall Beam RepairCity of Tukwila 6200 5outhcenter Boulevard, Tukwila WA 981$8 CONTRACT FOR SERVICES Contract Number: 23-061 Council Approval N/A This Agreement is entered into by and between the City of Tukwila, Washington, a non -charter optional municipal code city hereinafter referred to as "the City," and Structural Dynamics hereinafter referred to as "the Contractor," whose principal office is located at 20602 Grand Mound Way S.W. Centralia, WA 98531. WHEREAS, the City has determined the need to have certain services performed for its citizens but does not have the manpower or expertise to perform such services; and WHEREAS, the City desires to have the Contractor perform such services pursuant to certain terms and conditions; now, therefore, IN CONSIDERATION OF the mutual benefits and conditions hereinafter contained, the parties hereto agree as follows: 1. Scope and Schedule of Services to be Performed by Contractor. The Contractor shall perform those services described on Exhibit A attached hereto and incorporated herein by this reference as if fully set forth. In performing such services, the Contractor shall at all times comply with all Federal, State, and local statutes, rules and ordinances applicable to the performance of such services and the handling of any funds used in connection therewith. The Contractor shall request and obtain prior written approval from the City if the scope or schedule is to be modified in any way. 2. Compensation and Method of Payment. The City shall pay the Contractor for services rendered according to the rate and method set forth on Exhibit A attached hereto and incorporated herein by this reference. The total amount to be paid shall not exceed $31,554.66. 3. Contractor Budget. The Contractor shall apply the funds received under this Agreement within the maximum limits set forth in this Agreement. The Contractor shall request prior approval from the City whenever the Contractor desires to amend its budget in any way. 4. Duration of Agreement. This Agreement shall be in full force and effect for a period commencing April 7, 2023 and ending December 31, 2023, unless sooner terminated under the provisions hereinafter specified. 5. independent Contractor. Contractor and City agree that Contractor is an independent contractor with respect to the services provided pursuant to this Agreement. Nothing in this Agreement shall be considered to create the relationship of employer and employee between the parties hereto. Neither Contractor nor any employee of Contractor shall be entitled to any benefits accorded City employees by virtue of the services provided under this Agreement. The City shall not be responsible for withholding or otherwise deducting federal income tax or social security or contributing to the State Industrial Insurance Program, or otherwise assuming the duties of an employer with respect to the Contractor, or any employee of the Contractor. 6. Indemnification. The Contractor shall defend, indemnify and hold the Public Entity, its officers, officials, employees and volunteers harmless from any and all claims, injuries, damages, losses or suits including attorney fees, arising out of or in connection with the performance of this Agreement, except for injuries and damages caused by the sole negligence of the Public Entity. CA Revised May 2020 Page 1 of 4 Should a court of competent jurisdiction determine that this Agreement is subject to RCW 4.24.115, then, in the event of liability for damages arising out of bodily injury to persons or damages to property caused by or resulting from the concurrent negligence of the Contractor and the Public Entity, its officers, officials, employees, and volunteers, the Contractor's liability hereunder shall be only to the extent of the Contractor's negligence. It is further specifically and expressly understood that the indemnification provided herein constitutes the Contractor's waiver of immunity under Industrial Insurance, Title 51 RCW, solely for the purposes of this indemnification. This waiver has been mutually negotiated by the parties. The provisions of this section shall survive the expiration or termination of this Agreement. 7. Insurance. The Contractor shall procure and maintain for the duration of the Agreement, insurance against claims for injuries to persons or damage to property which may arise from or in connection with the performance of the work hereunder by the Contractor, their agents, representatives, employees or subcontractors. Contractor's maintenance of insurance, its scope of coverage and limits as required herein shall not be construed to limit the liability of the Contractor to the coverage provided by such insurance, or otherwise limit the City's recourse to any remedy available at law or in equity. A. Minimum Scope of Insurance. Contractor shall obtain insurance of the types and with the limits described below: 1. Automobile Liability insurance with a minimum combined single limit for bodily injury and property damage of $1,000,000 per accident. Automobile liability insurance shall cover all owned, non -owned, hired and leased vehicles. Coverage shall be written on Insurance Services Office (ISO) form CA 00 01 or a substitute form providing equivalent liability coverage. If necessary, the policy shall be endorsed to provide contractual liability coverage. 2. Commercial General Liability insurance with limits no less than $2,000,000 each occurrence, $2,000,000 general aggregate and $2,000,000 products -completed operations aggregate limit. Commercial General Liability insurance shall be as least at broad as ISO occurrence form CG 00 01 and shall cover liability arising from premises, operations, independent contractors, products -completed operations, stop gap liability, personal injury and advertising injury, and liability assumed under an insured contract. The Commercial General Liability insurance shall be endorsed to provide a per project general aggregate limit using ISO form CG 25 03 05 09 or an equivalent endorsement. There shall be no exclusion for liability arising from explosion, collapse or underground property damage. The City shall be named as an additional insured under the Contractor's Commercial General Liability insurance policy with respect to the work performed for the City using ISO Additional Insured endorsement CG 20 10 10 01 and Additional Insured -Completed Operations endorsement CG 20 37 10 01 or substitute endorsements providing at least as broad coverage. 3. Workers' Compensation coverage as required by the Industrial Insurance laws of the State of Washington. B. Public Entity Full Availability of Contractor Limits. If the Contractor maintains higher insurance limits than the minimums shown above, the Public Entity shall be insured for the full available limits of Commercial General and Excess or Umbrella liability maintained by the Contractor, irrespective of whether such limits maintained by the Contractor are greater than those required by this Contract or whether any certificate of insurance furnished to the Public Entity evidences limits of liability lower than those maintained by the Contractor. C. Other Insurance Provision. The Contractor's Automobile Liability and Commercial General Liability insurance policies are to contain, or be endorsed to contain that they shall be primary insurance with respect to the City. Any insurance, self-insurance, or insurance pool coverage maintained by the City shall be excess of the Contractor's insurance and shall not contribute with it. D. Acceptability of Insurers. Insurance is to be placed with insurers with a current A.M. Best rating of not less than A: VII. CA Revised May 2020 Page 2 of 4 E. Verification of Coverage. Contractor shall furnish the City with original certificates and a copy of the amendatory endorsements, including but not necessarily limited to the additional insured endorsement, evidencing the insurance requirements of the Contractor before commencement of the work. Upon request by the City, the Contractor shall furnish certified copies of all required insurance policies, including endorsements, required in this Agreement and evidence of all subcontractors' coverage. F. Subcontractors. The Contractor shall cause each and every Subcontractor to provide insurance coverage that complies with all applicable requirements of the Contractor -provided insurance as set forth herein, except the Contractor shall have sole responsibility for determining the limits of coverage required to be obtained by Subcontractors. The Contractor shall ensure that the Public Entity is an additional insured on each and every Subcontractor's Commercial General liability insurance policy using an endorsement as least as broad as ISO CG 20 10 10 01 for ongoing operations and CG 20 37 10 01 for completed operations. G. Notice of Cancellation. The Contractor shall provide the City and all Additional Insureds for this work with written notice of any policy cancellation, within two business days of their receipt of such notice. H. Failure to Maintain Insurance. Failure on the part of the Contractor to maintain the insurance as required shall constitute a material breach of contract, upon which the City may, after giving five business days notice to the Contractor to correct the breach, immediately terminate the contract or, at its discretion, procure or renew such insurance and pay any and all premiums in connection therewith, with any sums so expended to be repaid to the City on demand, or at the sole discretion of the City, offset against funds due the Contractor from the City. 8. Record Keeping and Reporting. A. The Contractor shall maintain accounts and records, including personnel, property, financial and programmatic records which sufficiently and properly reflect all direct and indirect costs of any nature expended and services performed in the performance of this Agreement and other such records as may be deemed necessary by the City to ensure the performance of this Agreement. B. These records shall be maintained for a period of seven (7) years after termination hereof unless permission to destroy them is granted by the office of the archivist in accordance with RCW Chapter 40.14 and by the City. 9. Audits and Inspections. The records and documents with respect to all matters covered by this Agreement shall be subject at all times to inspection, review or audit by law during the performance of this Agreement. 10. Termination. This Agreement may at any time be terminated by the City giving to the Contractor thirty (30) days written notice of the City's intention to terminate the same. Failure to provide products on schedule may result in contract termination. If the Contractor's insurance coverage is canceled for any reason, the City shall have the right to terminate this Agreement immediately. 11. Discrimination Prohibited. The Consultant, with regard to the work performed by it under this Agreement, will not discriminate on the grounds of race, religion, creed, color, national origin, age, veteran status, sex, sexual orientation, gender identity, marital status, political affiliation, the presence of any disability, or any other protected class status under state or federal law, in the selection and retention of employees or procurement of materials or supplies. 12. Assignment and Subcontract. The Contractor shall not assign or subcontract any portion of the services contemplated by this Agreement without the written consent of the City. 13. Entire Agreement: Modification. This Agreement, together with attachments or addenda, represents the entire and integrated Agreement between the City and the Contractor and supersedes all prior negotiations, representations, or agreements written or oral. No amendment or modification of this Agreement shall be of any force or effect unless it is in writing and signed by the parties. CA Revised May 2020 Page 3 of 4 14. Severability and Survival. If any term, condition or provision of this Agreement is declared void or unenforceable or limited in its application or effect, such event shall not affect any other provisions hereof and all other provisions shall remain fully enforceable. The provisions of this Agreement, which by their sense and context are reasonably intended to survive the completion, expiration or cancellation of this Agreement, shall survive termination of this Agreement. 15. Notices. Notices to the City of Tukwila shall be sent to the following address: City Clerk, City of Tukwila 6200 Southcenter Blvd. Tukwila, Washington 98188 Notices to the Contractor shall be sent to the address provided by the Contractor upon the signature line below. Structural Dynamics 20602 Grand Mound Way SW Centralia, WA 98351 16. Applicable Law: Venue: Attorney's Fees. This Agreement shall be governed by and construed in accordance with the laws of the State of Washington. In the event any suit, arbitration, or other proceeding is instituted to enforce any term of this Agreement, the parties specifically understand and agree that venue shall be properly laid in King County, Washington. The prevailing party in any such action shall be entitled to its attomey's fees and costs of suit. DATED this 4th day of April CITY OF TUKWILA HP icinecl via SeamlessDocs.com Day,HSafa, a_Ingn4a30-8a49_nn471 75, Allan Ekberg, Mayor 04-05-2023 ATTEST/AUTHENTICATED: eSigneci via SeamleeeUoce.00m Ch/tedtgOgialtettg Christy O'Flaherty, City Clerk APPROVED AS TO FORM: eSiined via SealnlessDocs.coln Key: aaeS588 icabh2c1,9ab1d4e96fe41sdd Office of the City Attorney , 20 23 CONTRACTOR: By: �aurt Printed Name: Clay Brunt Title: Principal Member Address: 1004 SW 119TH ST Burien, WA 98146 CA Revised May 2020 Page 4 of 4 ffRITERIUM GINEERS 3/21/2023 City of Tukwila Henry Andra 6200 South Center Blvd Tukwila, WA 98188 EXHIBIT A Re: Inspection to determine the extent of damage to three glulam beams exposed during residing the building. At your request, a limited structural inspection of the above property was performed on 3/16/2023 by Thomas D Fulgham, P.E. License issued by the State of Washington. INTRODUCTION The purpose of this inspection is to gain an understanding of damage to three beams, STANDARDS AND LIMITATIONS Our inspection and report have been conducted consistent with that level of care and skill that is ordinarily exercised by members of the profession providing the same services under similar conditions at the time the services are performed The scope of this inspection does not include a comprehensive evaluation for code compliance, governmental regulation compliance, fire safety, or hazardous materials in or around this building. It does not include an inspection of heating, cooling, plumbing, and electrical systems or repair designs. This report is an opinion about the condition of this portion of the building. It is based on the evidence available during a diligent inspection of all reasonably accessible areas. No surface materials were removed, no destructive testing undertaken, nor fizmishings moved. This report is not an exhaustive technical evaluation. Such an evaluation would cost many times more. This report is not to be considered a guarantee of condition, and no warranty is implied. As Professional Engineers, it is our responsibility to evaluate available evidence relevant to the purpose of this inspection. We are not, however, responsible for conditions that could not be seen or were not within the scope of our service at the time of the inspection. DESCRIPTION The parcel is King County Washington Parcel #3597000282 and the Assessor's report has the year built as 1979. For the purpose of this report the building faces Page 1 of 8 South towards South Center Blvd. The actual direction is closer to Southeast and the building has a basic "V" shape. Photo 1 The top of the photo is North. OBSERVATIONS: Photo 2 Looking North at the building. Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 2 of 8 L(1 Tukwila Finance Department Tukwil Tukwila Com Development Dep a • Se Photo 3 is looking at the approximate locations of the damage. Photo 4 is of area 1 Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 3 of 8 Photo 5 is the damage to area 1 king at area 2 Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 4 of 8 Photo 7 is of area 3 CONCLUSIONS AND RECOMMENDATIONS Area 1 exhibits the most damage and will require the most intervention. Plans of the original construction were made available by Henry Ancira. The glulam beams are 5 1/8" x 21" with floor joist of 2"x14" @16 OC with the center five joists running to the corners being 3"x 14". The joists are arranged in a diagonal to the exterior. The rim board is a 2"x 14" Photo 8 is of the plans showing the floor joist. Area 1 is in the lower center of the photo. Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 5 of 8 All three area need to be brushed to remove any dry rot remaining in the deteriorated wood and back filled with Abatron wood epoxy or similar applied using the manufactures instruction. Any other areas where rot is found can be brushed and epoxy applied. Area 1 will need to have 8" x 3/16"x8' flat strapped attached over the rot area with''/" bolts through the wood/epoxy to a backing strap of the same size. See figure 1 Many things have been discussed in this report. However, we realize that there may still be other things of interest to you that have not been discussed. Therefore, we encourage you to call with any additional questions you may have at our office: Criterium-Pioli Rowe Engineers, 425/486.4000. This report has been prepared in strict confidence with you as our client. No reproduction or re- use is permitted without expressed written consent. This report is the complete response to the inspection and should be read in fiill. It supersedes discussions during the inspection. Thank you for the opportunity to be of assistance. Sincerely, eF.-114.0 Thomas D. Fulgham Washington State PE #44432 Senior Engineer Figures below Attachment: Abatron WoodEpox brochure Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 6 of 8 \\— Area of dry rot Nailers Trimmed/coped to fit 2x4 Nailers \\_ -'''-\— " x7" grade 5 bolts placed 3" from each end then nominal 10 Set 2" from top and bottom. Use " he es on interior plate. Flat washer on both side 8"x " x 8' A36 plate Figure 1 Independently Owned and Operated 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 7 of 8 L�1 Figure 2 Interior View Independently Owned and Operated Interior Side 19125 North Creek Parkway, Suite 120 / Bothell, WA 98011 TF: 800.945.4189 / 0: 425.486.4000 / criterium-pioli-rowe.com Page 8 of 8 ABATRON ISO 9001 Registered Restore Rotted Wood in Three Easy Steps 1 Prepare Wood Remove old paint, dirt, and debris. Clean oily surfaces with detergent, water, or solvents. Apply LiquidWood To strengthen the wood, apply LiquidWood with a brush, or pour directly on the surface. LiquidWood penetrates and hardens. 3 Apply WoodEpox To rebuild missing pieces of wood and till cracks and holes, apply WoodEpox. When hard, it can be sanded, stained, painted, and nailed. LiquidWood'and WoodEpox® Wood Restoration System The Standard to Restore and Replace Wood LiquidWood® Reinforces, rebuilds and waterproofs wood by hardening after penetrating. Regenerates rotted window- sills, frames, structural and decorative parts, furniture, columns, boats, floors. Primer for Wood Epox. WoodEpox® Structural adhesive putty. Most versatile, high-strength, no -shrink adhesive paste to fill, repair and replace wood and other materials in structures, walls floors, furniture, sculptures.. A standard in workshops, plants, build- ings, museums, shipyards and homes. Specified by U.S Government agencies, state and national restoration centers, museums, architects and other profes- sionals, LiquidWood and WoodEpox represent the greatest advance in wood restoration history. They give new life to rotted, severely damaged wood, and are the only hope for parts that cannot be replaced because of size, shape or artistic reasons. Restored pieces are fully functional and often stronger and more durable than the original. Repairs are permanent. LiquidWood® Deep penetrating wood consolidant that regenerates and waterproofs rotted, dried -out, or spongy wood. Restores struc- tural strength and durability to wood fibers. With LiquidWood, a piece of deteriorated wood that could crumble under finger pressure can be impregnated and restored to a rigid, durable, water and weather resistant wood superior to the original. The hardened mass can be sawed, planed, routed, carved, drilled, nailed, sanded, glued, and painted. LiquidWood is also a primer for WoodEpox. Uses: LiquidWood is ideal for regenerating and water- proofing rotted, dried -out or spongy window sills, thresholds, window and door frames, columns, stair steps, balustrades, floors, capitals, moldings, doors, shutters, indoor and outdoor furniture, archaeological and art restoration, boats, and millwork of all kinds. Features & Benefits: LiquidWood has exceptional adhesion, structural strength, versatility, permanence, dimen- sional stability, and water resistance. LiquidWood A and B are easy to use, are 100% reactive compounds, and contain no VOC's or noxious odors. Technical Characteristics: Contents: LiquidWood consists of 2 clear, epoxy liquids: resin (A) and hardener (B). When A and B are mixed together in equal volumes, by simple stirring, a blend is formed with unique properties to impregnate and restore wood and other porous masses. Application: pour or brush on the wood where it penetrates the fibers and hardens into a water-resistant, distortion -free, high-strength mass in hours or minutes. 100% solids. 1/1 ratio. 30 minute pot life. 'I purchased your wood restoration kit this summer and used LiquidWood and WoodEpox in order to repair dam- aged windowsills that 1 thought were beyond repair.1 had rotted, wet, spongy windows in multiple spots throughout my home. 1 was absolutely amazed at how well your wood restoration kit worked, and I'm especially astonished by the properties of WoodEpox." P.S., Homeowner Fayetteville, North Carolina Kglcm2 Mpa Psi Tensile Strength 103 10.1 1460 Compressive Strength 366 36 5210 Flexural Strength 63 6.2 900 Hardness Shore D 42 Elongation 84% 'I purchased your wood restoration kit this summer and used LiquidWood and WoodEpox in order to repair dam- aged windowsills that 1 thought were beyond repair.1 had rotted, wet, spongy windows in multiple spots throughout my home. 1 was absolutely amazed at how well your wood restoration kit worked, and I'm especially astonished by the properties of WoodEpox." P.S., Homeowner Fayetteville, North Carolina WoodEpox® Shrink -free adhesive putty wood replacement compound that can be used in any thickness in structural and decorative applications to replace, repair, extend, or fill wood and other materials. Uses: WoodEpox is ideal for repairing, replacing, or adding to wood and most rigid surfaces, as well as to dried out, rotted or spongy wood consolidated with LiquidWood. Use on windowsills, thresholds, window and door frames, columns, stair steps, balustrades, floors, capitals, moldings, doors, shutters, indoor and outdoor furniture, statues, archaeological and art restoration. Features & Benefits: WoodEpox bonds permanently with high strength to most surfaces. It fills cracks, holes, and voids of any size without the shrinking and crumbling of common wood fillers. It can replace or add missing or new sections in window frames and sills, furniture, sculptures, structural and decorative components, indoors and outdoors. Because of its strength and durability, it is a truly perma- nent solution where alternatives would surely fail. WoodEpox succeeds because it can be painted, stained, wood -grained, sawed, nailed, planed, sanded, carved, and machined like wood. Can be cast into shapes and sculpted by hand before hardening. It can also be carved after hardening. Bonds equally well to ceramics, concrete, metal, glass, fiberglass, and most rigid surfaces. Contains no V❑C's or noxious odors. It has a light, neutral color that can be changed, while mixing with stains, dyes, or pigments. Has a no slump paste consis- tency that allows it to be applied like a putty to fill gaps, holes, or to build-up virtually any thickness and shape. Technical Characteristics: Contents: WoodEpox is a light- weight epoxy adhesive system consisting of 2 components: resin paste (A) and hardener paste (B). When A and B are mixed in equal volumes, the blend hardens within 1-2 hours into a Tight -weight, non -shrinking, tough adhesive mass with high dimensional stability, chemical, water, heat and weather resistance. 100% solids. 1/1 ratio. 20 minute pot life. LiquidWood and WoodEpox are ideal for log home repair and restoration Kg/cm2 Mpa Psi Tensile Strength 176 17.5 2500 Compressive Strength 389.8 37.92 2300-2800 Hardness Shore D 53-55 Elongation 4% LiquidWood and WoodEpox are ideal for log home repair and restoration Related Products AbosolvTM: Solvent for LiquidWood. Use for thinning LiquidWood and cleaning up. Abocure 79121TM: Cold weather hardener for use with LiquidWood (A) that can be applied in sub -freezing weather with excellent results. When combined with LiquidWood (A), Abocure 7912-1 permits LiquidWood to harden overnight, even in subfreezing weather conditions. Recommended for exterior use only. Abocure 8512-1TM: Paste -like cold weather hardener for use with WoodEpox (A). It can be applied in sub -freezing weather with excellent results. When combined with WoodEpox (A), Abocure 8512-1 permits WoodEpox to harden without an external heat source. Recommended for exterior use only. Pigments: A variety of pigments that can be blended into WoodEpox while mixing uniformly to match wood tones. One or more can be blended to create depth of color and varying tones. Pigments include (from left to right): Dark Brown, Brick Red, Dark Yellow and Black. ClearstripTM: Environmentally friendly paint remover designed to remove multiple layers in one action. Will not mar normal wood patina. It is biodegradable, nonflammable and very low odor. Contains no caustic or methylene chloride. Can be used on most varieties of paints and varnishes. For a complete description of ABATRON's products and accessories related to wood restoration visit the company's website below or call for a free catalog. Follow These Simple Instructions: 0 0 °e4 0 1. Apply to clean and dry surface after removing contaminants, oil, grease, wax, old paint and debris. 2. Mix a volume of LiquidWood A with an equal volume of LiquidWood B for at least one minute with blade or paddle. 3. Apply LiquidWood mix to deteriorated wood by brushing, pouring or injecting. 4. For deeper penetration into wood, drill small holes through side grain and across end grain, and pour LiquidWood into holes. Repeat process until wood is saturated. 5. Mix thoroughly a volume of WoodEpox A with an equal volume of WoodEpox B. 6. Apply WoodEpox to wood primed with LiquidWood while LiquidWood is still "tacky" to fill cracks, holes and replace missing wood. 7. Sand, plane, shape, paint and stain restored wood as desired. ABATRON 5501 95th Ave. Kenosha, WI 53144 800-445-1754 www.abatron.com info@abatron.com 4 Rages Rolled Wad C 1112009 AOAYRON CORP. APlO!i/ROWf CRITERIUM ENGINEERS AGREEMENT FOR SERVICES Building Inspection Criterium-Pioli-Rowe Engineers 19125 North Creek Parkway #120 Bothell, WA 98011 This is the complete agreement regarding engineering services to be provided by Criterium-Pioli-Rowe Engineers related to the property described below. This is intended to be a legally binding agreement. Please read it carefully. CLIENT & Location: City of Tukwila, Henry Ancira 6200 South Center Blvd, City Hall Tukwila, WA DESCRIPTION OF PROPERTY: Approximate year constructed: 1977 Single family? YES X NO Additional buildings? _YES X NO INSPECTION SCHEDULE: DATE: 3-16-2023 TIME: _10:30 ENGINEER: Thomas Fulgham, PE Approximate total size: 24,000 Sq Feet Other: Commercial Building If Yes, describe INSPECTION SERVICES TO BE PROVIDED (see page 2 for descriptions, initial choice): STANDARD HOME INSPECTION EXHAUSTIVE INSPECTION XXX STRUCTURAL INSPECTION SPECIFIED INSPECTION TOTAL FEE by check: $1320. The fee is to be paid at or before the inspection. If the property differs significantly from the description above, the fee may be adjusted. A 24-hour notice of cancellation is requested. Otherwise, a cancellation fee applies. If a re -inspection is requested, a separate agreement and an additional fee will apply. The Standard Home Inspection is performed in accordance with the Standards of Practice State of Washington, Chapter 308-408C WAC. This inspection does not include investigation of mold, asbestos, lead paint, water, soil, air qua]ity, or other environmental issues. The results of the inspection will be provided in a written report prepared exclusively for your benefit. Reliance upon our report by other parties is strictly prohibited. If you choose to share our report, you agree to indemnify, defend and hold harmless the engineer from any third -party action. You are encouraged to be at the inspection to discuss your questions and concerns. However, the written report is the exclusive source of information regarding our observations and conclusions. All discussions that occur at the inspection are preliminary in nature and should not be the basis for any final decisions regarding this property. Further, owning any property involves some risk. No inspection can reveal everything that might be of interest or significance to you regarding this property. Our inspection is not a guarantee or warranty regarding the condition of this building. Except as otherwise noted herein, our maximum liability for loss suffered by the CLIENT due to any cause is limited to our inspection fee. If you bring an action against the ENGINEER and the ENGINEER prevails, ENGINEER shall be entitled to recover costs and expenses, including reasonable attorneys' fees and costs. Client Initial Engineer Initial Page 1 of © Criterium Engineers 2003 Effective September, 2009 AGREEMENT FOR SERVICES (continued) Building Inspection CHOICE OF INSPECTION SERVICES: After reviewing these descriptions, both the client and engineer should Waal where noted to nndicate the type of inspection chosen. As our clienau you are making a choice of services to be provided If you have duty questions, please contact us immediately. Phone: 425-486-4000 STANDARD HOME INSPECTION: A limited visual inspection to identify significant deficiencies and/or repairs needed in the major systems (structure, heating, air conditioning, plumbing, electrical, roof, exterior, interior, (int'!) insulation, ventilation, fireplaces and stoves, site, attached garages or carports) as well as provide a general understanding of the property. This is a limited inspection based on visible evidence readily available during the _ inspection (without moving furnishings, removing finishes, etc.) and is the opinion of the engineer performing the (int?) inspection. Our maximum liability for loss suffered by the CLIENT due to any cause is limited to our inspection fee. LIMITED STRUCTURAL INSPECTION, focused on the condition of three glulam beams: An inspection and evaluation that is limited to reasonably available and visible st uctural components. Review and comments on (int?) available construction plans. Activities such as probing with an awl, measuring framing members, and limited excavation around the foundation and/or deterrnination of squareness, levelness and plumbness may be included in such an evaluation. Unless otherwise recommended or designated in writing, no soils investigation or invasive (int?) testing is included. Further, no inspection or evaluation of any other systems such as plumbing, electrical, mechanical or interiors is included. Design work is not included. The report will follow within one week. Some research items may lag this timeframe. EXHAUSTIVE INSPECTION: A STANDARD HOME INSPECTION plus invasive testing and/or equipment disassembly as approved by client and property owner, in advance, to gather all reasonably available and relevant (int?) information about the property. This inspection is specifically not limited to readily available visible evidence and requires invasive testing which may include moving furnishings, removing wall coverings and/or drilling into wall cavities (to check for structural damage, for example) and requires the current owner's written permission. Unlike (int?) the Standard or Limited Inspection, our maximum liability for loss suffered by the CLIENT due to any cause is limited to our inspection fee or $10,000.00, whichever is greater. In addition, because of the additional services provided under an Exhaustive Inspection, the results of the inspection take longer than a Standard Inspection. SPECIFIED INSPECTION: An inspection and evaluation that is limited only to the following: (int?) The components in our STANDARD, EXHAUSTIVE and LIMITED STRUCTURAL INSPECTIONS are not included in this work. This inspection and evaluation are limited to reasonably available and visible components of the items listed above. Design work, if required, is not included. (int?) MOLD EXCLUSION: This inspection is not for the specific purpose of determining the presence of organic substances in the building. If, however, during the inspection, we knowingly encounter such substances, we will notify you of the presence of these substances without accepting any liability whatsoever for any damage or harm caused by the substances. It is your responsibility to deterrnine if further testing is required and to retain an independent, qualified professional to perform such tests. The above is understood and accepted. Client Signature (one signature binds all parties) Engineer Signature (Date) (Date) IF PAYING BY CREDIT CARD, A 3.O% convenience fee applies Please call the office prior to the appointment; or provide the following information for payment at the time of inspection: Please specify: Type of credit card - MasterCard - VISA (circle one), Card Number Expiration Date , The V -code (the 3 -digit code on the back of your card) The Cardholder Name (as it appears on the card) The Mailing Address of Cardholder Page 2 of 2 © Criterium 2003 THOMAS D. FULGHAM P.E. Professional Objectives Design -Build Engineering/Project Management/Commissioning: where experience in permitting, project engineering, project management, maintenance systems and plant operations combine to provide a safe and effective project. OEM equipment and integration of manufactured components into systems for delivery of wet and dry raw materials to mixers for a consistent product. Profile • Working in a wide variety of industries (mining, sawmill, wall board, extruded tile) have provided a strong background into system requirements and short falls. • Prepare and evaluated bid and equipment specification • Administer both fabrication and construction contracts. • Evaluate and improve process flow from personnel (safety/ergonomics), engineering, and economic stand point. • Evaluated equipment failures and implement engineering, personnel and maintenance procedures to minimize the future failure. • Implement computerized maintenance and inventory control programs. • Strong communication skills using AutoCAD MEP 2017, MS Projects, Word, Excel, and Access. LICENSE Washington Professional Engineer 44432 PE Montana Professional Engineer 12881 PE Washington State Class A CDL PROFESSIONAL MEMBERSHIP Society for Mining, Metallurgy & Exploration American Society of Mechanical Engineers EDUCATION University of Montana, Butte B.S.-Mining Engineering 1997 EMPLOYMENT HISTORY FULGHAM ENGINEERING, LLC 7407 277TH ST E GRAHAM, WA 98338 ENGINEER/MANAGER. CONTRACT ENGINEERING, Design and permit Single Family Residence, food service trucks and trailers, design and fabrication of equipment. Boral Roofing a Division of Bora INA 10920 5 Steele St. Lakewood, WA 98499 EnRineerfProject Manager. Design and equipment acquisition for manufacturing concrete roofing tile. Site management, installation and commissioning. Research and development of a new process for extruded tile as a contractor then as a direct hire. (September 2009 to July 2014) Gypsum Technologies Inc. 6760 Campobello Road Mississauga, ON L5N 2L8 EnRineerIProject Manager. Design and equipinent acquisition for gypsum mills/production lines and site management of installation and commissioning of complete plants. Research and development of a new steain process to lower the water demand to produce wall board. (July 2005 to September 2009) Page 2 of 2 Mem rieor of... CHANCE 141_1_1" ICE N El-104CMIS C..rriflet& lns fa ll mrs for. __ c ETM .. (1 ICC! 1'92.2" it A a L ALS - CHANGING HISTORY STRUCTURAL DYNAMIC Clay Brunt - Principal clay@structuralusa.com 20602 Grand Mound Way S.W. Centralia, WA 98531 ESTIMATE OWNER - CITY OF TUKWILA, PHONE - 206.571.6294 E-MAIL 1 - SITE ADDRESS - 1) Project Bid -# c/o Henry Ancira PHONE/MBL DATE - 3.26.2023 6200 SOUTH CENTER BLVD, TUKWILA , WA 98188 Supply material and labor for the installation of the items listed below - NOTE: THIS ESTIMATE 15 BASED ON THE INFORMATION AND RECOMMENDATIONS CONTAINED IN THE INSPECTION REPORT BY Criterium, Pioli, Rowe, - Thomas D. Fulgham, P.E. BEAM 1 - REMOVE AND REINSTALL EXISTING CEILINE TILES, WORK AREA ONLY, TEMP REMOVE AND RE -INSTALL ELECTRICAL CONDUIT PREP ROTTEN AREA, APPLY WOOD TREATMENT/REPAIR PATCHING PRE-STREES BEAM, PG 1 of 2 INSTALL STEEL PLATES INSTALL NEW PT 2X4 FIRING FRAMING BEAM 2 - PREP ROTTEN AREA, APPLY WOOD TREATMENT/REPAIR PATCHING INSTALL NEW PT 2X4 FIRING FRAMING BEAM 3 - PREP ROTTEN AREA, APPLY WOOD TREATMENT/REPAIR PATCHING INSTALL NEW PT 2X4 FIRING FRAMING SPECIAL INSPECTIONS BY OWNER PERMITS BY OTHERS ENGINEERING BY OTHERS PRE-TAX TOTAL = $ $ 28,660.00 SALES TAX 10.10% 0 NOTAL BASE AMOUNT = *** Estimate pricing good for 30 days from date listed above and subject to change as per final engineering. Additional labor will be billed at $145.00 per hour. PG 2 of 2 EXCLUSIONS Permits and Fees - Any and all costs and fees associated with the submittal and acquisition of all required permits for all phases of the project, Engineering, Electrical Work, Mechanical Work, Above ground and Underground Utilities Work - Material, installation or excavation and/or removal of any electrical, mechanical, aboveground or underground tanks, natural gas lines or any other object that was not exposed to the naked eye upon site inspection. Repair of any and all water, sewer, gas or electrical lines. Hazardous Conditions —Any and all testing and removal of all hazardous material that directly or indirectly affects project area or workers access to project area. Concrete Slab removal, installation or lifting. Final landscaping, shoring, or excavation. Black -top pavement patching. Repairing components of Interior or Exterior of structure that are damaged pre -leveling or will be damaged due to leveling process ( cracked walls etc.). Dewatering work area. Special inspections or observations. Locating all underground utilities. ECO -FRIENDLY 41, itn ' kr, '4', MADE IN U.S.A PRQ,IWCT