Loading...
HomeMy WebLinkAboutPermit 2012 - Bestway Motor FreightBUILDING' PERMIT DATE OF ISSUANCE December 12. 1980 JOB ADDRESS 6440 S. 143d LEGAL LOT NO. 19.20 -21 DESCR. F20- 15- 16 -17 -18 OWNER Bestway Motor Freight, Inc. ADDRESS CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 EXPIRES June 12. 1981 7 *iZH211 TRACT SEE ATTACHED SHEET PHONE 682 -8585 ZIP CONTRACTOR PHONE ADDRESS ZIP Jalco, Inc 776 -8424 LICENSE NO. SST NO. JA -LC -0 25206 C600- 135 -988 BUILDING USE Freight Terminal CLASS OF WORK ►ANEW ❑ADDITION El REMODEL ❑REPAIR ❑OTHER (Specify) BLDG. 1st FL. I 2nd FL. I BASEMENT I GARAGE I DECK I MEZZANINE I OF STORES I TOTAL S.F. I VALUATION AREA 300,UUU.UU 6537 1804 8341 31144811XIN 1 CE T Y TH HE ABO VE FORMATION IS TRUE AND CORRECT, FEE BUILDING 587.00 THA TH APPLBLE C TUKWILA REQUIREMENTS WILL BE DISTRIB. PLAN RVW. MET, D THAT I kM A ORIZED AGENT FOR THE PROJECT. DEMOLITION BOND OTHER I OWNER AGENy GNATURE TOTAL 969.00 COMMENTS: TYPE CONST. I OCC, GROUP I OCC. LOAD I FIRE ZONE I USE ZONE I AUTO SPRINKLERS REQ. smoke Dt. VN B2 207 M1 YES NO X yes THESE INSPECTIONS ARE REQUIRED BY LAW 1. Driveway 2. OK to 3. Roof 4. OK to 5. Wall- 6. Structure approach and pour footing sheathing enclose board complete and/ slope and /or and nailing framing nailing or OK to foundation OK OK occupy FOR RII -N PE TIQN CALL 433 -1849 BUIL G FI AL, CITY OF TUKWILA THIS PERMIT MUST BE POSTED CONSPICUOUSLY ON BUILDING A PERMIT NUMBER 70/2 BUILDING PERMIT DATE OF ISSUANCE JOB ADDRESS i;j4 S). 1436 LEGAL LOT NO. DESCR. OWNER or Freight, Inc. i" 'Mot ADDRESS CITY OF TUKWILA 6200 SOUTHCENTER BOULEVARD TUKWILA, WASHINGTON 98188 EXPIRES i 1 �ii PERMIT NUMBER��� BLOCK TRACT SEE ATTACHED SHEET PHONE ZIP CONTRACTOR PHONE ADDRESS ZIP LICENSE NO. SST NO. 1 /l- •l.l: -.�f :.`:i,'�lt (,(j(i�) ^,c�r���ls BUILDING USE I Fniklh't: t� rl1 ?inal CLASS OF WORK IONEW ❑ADDITION ❑REMODEL ❑REPAIR ❑OTHER (Specify) BLDG. 1st FL, I 2nd FL. I BASEMENT I GARAGE I DECK I MEZZANINE I OF STORES I TOTAL S.F. I VALUATION AREA I CERTIFY THAT THE ABOVE INFORMATION IS TRUE AND CORRECT FEE BUILDING THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE DISTRIB. PLAN RVW. 'Ji!.I'l1 MET,'AND..THAT I AM AN AUTHORIZED AGENT FOR THE PROJECT DEMOLITION f BOND 11.92•lU>t�''_......_.. OTHER OWNER AGENT SIGNATURE t TOTAL C COMMENTS: I r' I TYPE CONST. I OCC. GROUP I OCC. LOAD I FIRE ZONE USE ZONE I AUTO SPRINKLERS REO, OYES F-1 NO 1. Driveway approach and slope FOR INSPECTION CALL 433 -1849 fir. �o BUILD(�1G "OFFI,IAL., CITY OF'.TUKWILA THIS PERMIT QST,13t.E1,POSTED CO THESE INSPECTIONS ARE REQUIRED BY LAW 2. OK to 3. Roof l 4. OK to?� 5. Wall- 6. Structure pour footing sheathing enclose board complete and/ and /or and nailing framing nailing or OK to foundation OK O,K occupy QC/ A/I irf� m September lO, 1980 Al Pieper Building bepartment City of Tukwila Ke2 Bestway Motor Freimht Dear All In reviewing the above mentioned Project p1ansv Please note the' followinN itemst m 1^ Per UFC Section 124104(b)y EXIT doors shall be openahle ro' 'theinside *ithout the use of a key or any special knowledde or effort, 2^ Per UFC Section 0^113(b), at every reouired exit doo/wag, and Nhermver otherwise reouired to clearly indicate, thd direction of e resm, an EXIT sign With letters at least six inches high,and readily distinguishable shall be 171ai6 tained^ 3 z Hopb etationsAre remuired er City OrYi6 1141^ (Plans must-be submittedtO the FireM$rshal for��approv6l priub instml�lit ��on� 4^ Fir�� extinmuisheys shall-be proVided'Per NF POP 0, as'a Insta]l the f�l1owin��auantity of 2-1/2 mallonprgssurized water extinguishers; (11 lnytalI the following ouant1ty of 2~Ar A0BIC "All,PUrpose" dQ chumical fire extinguishers: (2) 5^ Per NFPA reoVirements, extinguishers with m_gross� weightuf 40 poVnds 61 less shall be hung yo that the toP of the extinouisher isnot higheT than 66 inchesabove the' flooy^ Units whighing morpAhan40 hoVnds shall bk not hither 'thin 42 1 inches above the floor^ Extioouishers sh�ll be locat6� s/» as to 'be���n plain vioN (i� all poomiblo)y ur,if not in plain viewv thew be Mentif1ed withv; sianstatipg "Fire ExtiDguisher �with an ""4 "1 4 4 4 k A .."4 Gty of Tukwila Fl re Depertmeril: 444 Andover Perk'.East, Tukwlla;,Weshlnaton 98188 (208) 575 -440 wqs City of Tukwila y 2 6200 Southcenter Boulevard w o Tukwila, Washington 98188 1908 Public Works Department 433 -1850 December 10, 1980 Sid Eland JALCO, Inc. 6628 212th SW Lynwood, Washington 98036 RE: Bestway Motors Dear Mr. Eland: The site plan of Sheet 2 of 3 has been approved per the following comments and conditions: The developer shall be required to obtain the following permits by this Department 24 -hours prior to construction: Hauling Hauling permits must be applied for when any hauling is done on City streets. A $2,000 bond must be posted along with a copy of the hauler's certificate of insurance. Permit fee is $25.00 unless the hauler has a City Business License where the fee is waived. Sanitary Side Sewers Sanitary sewers shall be a minimum of 6" diameter, of concrete or PVC (schedule 35 minimum) with class B bedding or better. Provide cleanouts at all entrances to building, horizontal and vertical bends on sanitary sewer lines. Sanitary sewer permit fee for each building is $170.00. (Special connection charges are waived by the property's past participation in LID #20). Sanitary side sewers shall connect into the existing 6" stubs at the property line. Curb Cut /Access /Sidewalk Provide minimum 6 LP curb return radii at all curb entrances. Concrete curb aprons shall be provided at all entrances. The Board of Architectual Review has previously approved an access point at the West edge of your property. At present Public Works staff do not forsee any safety problem with this access considering how adjacent properties have been developed. However,'in the future, if a safety problem does arise, the City may require the property to eliminate this access point, or relocate the access. Prior to issuance of this permit, a sidewalk plan shall be submitted for PWD review and approval. The sidewalk width shall be 6' per the City's current sidewalk Ordinance #1158, and per the City of Tukwila Standard Plan. A minimum twenty -four foot wide curb apron is required at all entrances. Permit fee $25.00 per building. Storm Drainage: As all private property drains into an underground system 1:....., e_N BESTWAY MOTORS (Cont.) 2 storm system directly to the Green River, no permit is required by the City. Permits, as required, are from King County Hydraulics. Domestic Water Meters Water meters hall be provided in the public right -of -way, or in easements, preferably at the property line. The size of these meters shall be determined through the Fire Department's review process, yet uncompleted. Fees will be based on the size of the meters. Prior to issuance of the water meter permits, provide 6 sets of plans that show the size, location and points of connection of the meters and service lines from the existing main to the buildings for Public Works Department review and approval. Fees for special connection charges for water hookup to the City mains will also be computed and applied as part of the water -meter permit fee, per ordinance. Fire Hydrant /Loop, /Sprinkler System Fire services shall be provided per the requirements of insurance underwriters and the Tukwila Fire Department prior to Public Works Department approval. Please submit these plans for Tukwila Fire Department's review and approval and resubmit to the Public Works Department. A sprinkler vault for the fire loop/hydrant /sprinkler system, if required by the Fire Dept., shall be per Tukwila Public Works Department Standard Plan and Water Department requirements. This sprinkler vault must be located in private right -of -way, but not in the driveways due to the PIV post.above ground. All piping shall be DIP, Cl. 1152 Provide thrust blocks'at all junctions, bends, hydrants, and ends of pipe for fire protection system. Provide valuing to hydrants, if required, per Tukwila Standard Plan for hydrants. Permit fee $25.00. Landscape Irrigation This plan shall be reviewed per future plan submittal. Provide six (6) sets of water irrigation.plans for Public Works review and approval prior to issuance of irrigation permit. Permit fee $25.00. City of Tukwila .J 6200 la, Washington 98188 Southcenter Bou Tukw ip Public Works Department 433 -1850 1908 December 10, 1980 Sid Eland JALCO, Inc. 6628 212th SW Lynwood, Washington 98036 RE: Bestway Motors Dear Mr. Eland: The site plan of Sheet 2 of 3 has been approved per the following comments and conditions: The developer shall be required to obtain the following permits by this Department 24 -hours prior to construction: HaulinQ,- Hauling permits must be applied for when any hauling is done on City streets. A $2,000 bond must be posted along with a copy of the hauler's certificate of insurance. Permit fee is $25.00 unless the hauler has a City Business License where the fee is waived. Sanitary Side Sewers Sanitary sewers shall be a minimum of 6" diameter, of concrete or PVC (schedule 35 minimum) with class B bedding or Provide cleanouts at all entrances to building, horizontal and vertical bends on sanitary sewer lines. Sanitary sewer permit fee for each building is $170.00. (Special connection charges are waived by the property's past participation in LID 120). Sanitary side sewers shall connect Unto the existing 6" stubs at the property line. Curb Cut /Access /Sidewalk Provide minimum 6 LF curb.return radii at all curb entrances. Concrete curb aprons shall be provided at all entrances. The Board of Architectual Review has previously approved an access point at the West edge of your property. At present Public Works staff do not forsee any safety problem with this access considering how adjacent properties have been developed. However, in the future, if a safety problem does arise, the City may require the property to eliminate this access point, or relocate the access. Prior to issuance of this permit, a sidewalk plan shall be submitted for PWD review and approval. The sidewalk width shall be 6' per the City's current sidewalk Ordinance #1158, and per the City of Tukwila Standard Plan. A minimum twenty -four foot wide curb apron is required at all entrances. Permit fee $25.00 per building. Storm Drainage: As all private property drains into an underground system storm system directly to the Green River, no permit is required by the City. Permits, as required, are from King County Hydraulics. Domestic Water Meters Water meters shall be provided in the public right -of -way, or in easements, preferably at the property line. The size of these meters shall be determined through the Fire Department's review process, yet uncompleted. Fees will be based on the size of the meters. Prior to issuance of the meter permits, provide 6 sets of plans that show the size, location and points of connection of the meters and service lines fromtthe existing main to the buildings for Public Works Department review and approval. Fees for special connection charges for water hookup to the City mains will also be computed and applied as part of the water meter permit fee, per ordinance. Fire Hydrant /Loop /Sprinkler Svstem Fire services shall be provided per the requirements of insurance underwriters and the Tukwila Fire Department prior to Public Works Department approval. Please submit these plans for Tukwila Fire Department's review and approval and resubmit to the Public Works Department. A sprinkler vault for the fire loop/hydrant /sprinkler system, if required by the Fire Dept., shall be per Tukwila Public Works Department Standard Plan and Water Department requirements. This fire sprinkler vault must be located in private right -of -way, but not in the driveways due to the PIV post above ground. All piping shall be DIP, Cl. #52 Provide thrust blocks at all junctions, bends, hydrants, and ends of pipe for fire protection system. Provide valving to hydrants, if required, per Tukwila Standard Plan for hydrants. Permit fee $25.00. Landscape Irrigation This plan shall be reviewed per future plan submittal. Provide six (6) sets of water irrigation.plans for Public Works review and approval prior to issuance of irrigation permit. Permit fee $25.00. Drovide all pipes with 12" minimum cover. Sincerely,. Phillip R. Fraser Shnior Engineer BUILDING DEPARTMENT CI TY of TU KW I LA RECEIVED s TUKWILA, WASHINGTON 98188 CITY OF TUKWILA 433 -1849 SEP 9 1980 APPLICATION FOR PERMIT SIOUlNG DIM. DATE 5 Rel IPERMIT NO. WHEN VALIDATED EXPIRES JOB ADDRESS D 5 LEGAL LgT NO,. l 2d ze BLOCK TRACT DESCR. ;�q /,t"_ 16 -I t' El SEE ATTACHED SHEET �g OWNER'--y U_)4V mc7 �/Zc A a7 /l/ (PHONE 6Z O.J OS cN,�? C9 ADDRESS ZIP I 776 ��z e CONTRACTOR --��/G 1 PHONE ADDRESS t: 4-0 ZIP LICENSE NO �2.5 z IS ST NO. BUILDING USE L TEEN i CL�ASS�F WORK L!'IVEW ADDITION REMODEL REPAIR OTHER (Specify) BLDG. 1st FFL.►7I 2nnd FL. 1 BASEMENT I GARAGE I DECK I MEZZANINE I OF STORES I TOTAL S.F. VALUATION AREA 71 1/ I I I I I L�/ I �Q/ O d a, n 4 NAME OF APPLICANT (PLEASE PRINT) ADDRESS I PHONE I CERTIFY THAT THE INFORMATION FURNISHED BY M S TR E AN CO CT AND THAT THE APPLICABLE CITY OF TUKWILA REQUIREMENTS WILL BE MET. SIGN TUR APPLI CANT I TYPE CONST. I OCC. GROUP �7 I 5 PLAN I I SENT _PLANS: RVW. I DETECTOR FIRE DEPT. I I ,q YES NO PLANNING/ I RETURNED I SEPA ,S 17 a 6 PUBLIC WKS. I DISTRIB. PLAN RVW. I COMMENTS: DO NOT WRITE BELOW THIS LINE SM OCC. LOAD I FIRE ZONE I USE ZONE I AUTO SPRINKLERS REQ. I DETECTOR v7 I ,q YES NO (3 YES 0 NO I RETURNED I APPROVED FEE BUILDING I ,S 17 a 6 I I DISTRIB. PLAN RVW. I i b' 0 DEMOLITION I I BOND 1 OTHER I I TOTAL 67 Cf 0 C) I I I RECEIPT NO I' APPROVED FOR ISSUANCE S y;1- WsY 7, 0 c Energy Information Relating to Warehouse f ♦7 Chapter six of the Energy Code is used because of the sI..___ footage of Office area (3,324 square feet) and the unheated ware a house (50 maximum). Exterior wall area 2,337 square feet glass area 490 sq. ft. 21% in Zone I All piping installed to serve the building or with -in the building shall be thermally insulated. ROOF outside air film /15 mph .'wind 0.17 metal roof. 0.00 air space .85 insulation 24.00 suspended ceiling.tiles'. 1.19 inside air film ..68 TOTAL R VALUE" 26.89 20%'for continuous insulation 5.26 3�2. 15 TOTAL U VALUE .03 WALL outside air film /15 mph. wind. 0.17 metal siding 0.00 buildin g paper a er 0.06 1/2" ply sheeting 1.3,2 3" batt R -11 11. 5/8" g.w.b— 0.50 inside air .68 TOTAL R VALUE 13.73, TOTAL U VALUE .07 SLAB ON GRADE inside air film 1.68 carpet and rubber pad 1.23 concrete slab 1/2 ridged insulation 2.05 vapor barrier 0.00 TOTAL R VALUE 5.28 TOTAL U VALUE .18 FLOOR AT OVERHANG" i., inside air film' .68 carpet and pad" 1.23 3/4" plywood 94 7h" air space .SO 2h" batt insulation 7..001 5/8" g.w.b. .50 outside air film .17 TOTAL R VALUE 11.02 TOTAL U VALUE .09 i Energy Information mating to Warehouse for Chapter six of the Energy Code is used because of the small square footage of Office area (3,324 square feet) and the unheated ware- house (50 maximum). Exterior wall area 2,337 square feet glass area 490 sq. ft. 21% in Zone I All piping installed to serve the building or with -in the building shall be thermally insulated. ROOF outside air film /15 mph wind 0.17 metal roof 0.00 air space .85 :7 -3/4" insulation 24:00 suspended ceiling tiles 1.19 inside air film .68 TOTAL R VALUE 26.89 20% for continuous insulation 5.26 3,2 ."15 TOTAL U VALUE .03 WALL outside air film /15 mph wind 0.17 metal siding 0.00 building paper. 0.06 S 1/2" ply sheeting 1.32 1 3" batt R -11 11.00 f 5/8" g.w.b. 0.50 inside air ,68 TOTAL R VALUE'• 13.73 TOTAL U VALUE. .07 SLAB ON GRADE inside air film 1.68 carpet and rubber pad.,. 1.23 concrete'slab 4" .32 1/2" ridged insulation 2.05 vapor barrier 0.00 TOTAL R VALUE 5.28 TOTAL U VALUE .18 FLOOR AT OVERHANG inside air film .68 carpet and pad 1.23 3/4" plywood .94 7k" air space .50 .2h" batt•insulation 7.00 5/8" g.w.b. .50 outside air film. .17 TOTAL R VALUE 11.02 TOTAL .0 VALUE .09 x x x x x x x x x x x x x x x x x