Loading...
HomeMy WebLinkAboutPermit EL18-0039 - TUKWILA SCHOOL DISTRICT / TECHNOLOGY CENTER - DEMO FIXTURES AND INSTALL LIGHTING FIXTURES, RECEPTACLESTSD - TECHNOLOGY CENTER 4060 S 144T" ST ELI 8-0039 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.sov 1523049013 4060 5 144TH ST ELECTRICAL PERMIT Project Name: TSD - TECHNOLOGY CENTER Permit Number: Issue Date: Permit Expires On: EL18-0039 2/28/2018 8/27/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KING CO LIBRARY SYSTEM 960 NEWPORT WAY NW , ISSAQUAH, WA, 98027 NICOLE HEAVIN PO BOX 5308 , LYNNWOOD, WA, 98046 SYSTEM SOLUTIONS OF WA INC PO BOX 5308 , LYNNWOOD, WA, 98046 SYSTESW900PD Phone: (425) 249-2076 Phone: (425) 249-2076 Expiration Date: 10/1/2018 DESCRIPTION OF WORK: DEMO EXISTING FIXTURES, INSTALL NEW LIGHTING FIXTURES, INSTALL RECEPTACLES Valuation of single family: $0.00 Valuation of mf/comm: $75,000.00 Type of Work: TENANT IMP Fees Collected: $1,777.83 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: a- ---D-0i 6 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws ting construction or the performance of work. I am authorized to sign and obtain this development pirmit and gree t he conditions attached to this permit. Signature: Print Name: ler\i Date: a.- a c,; This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov 'N Electrical Permit No. t )-1 06 Yi Project No. Date Application Accepted: 1.11.—(9 Date Application Expires: -1 For ojlce use on ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1523049013 King Co Assessor's Tax No.: Site Address: 4060 S 144th St. Tukwila, WA 98168 Suite Number: New Tenant: 1 1 Yes Tenant Name: Tukwila School District Auxiliary Projects PROPERTY OWNER Name: Jeff Feeney Name: Tukwila School District City: Tukwila State: WA Zip: 98168 Address: 4640 S 144th Street Email: City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jeff Feeney Address: 4640 S 144th St City: Tukwila State: WA Zip: 98168 Phone: 206.979.9370 Fax: Email: Floor: ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: System Solutions of WA Address: PO Box 5308 City: Lynnwood State: WA Zip: 98046 Phone: 425-249-2076 Fax: Contr Reg No.: SYSTESW900P( Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 75,000 Scope of Work (please provide detailed information): Demo existing fixtures, install new lighting fixtures, install receptacles Will service be altered? El Yes 0 No Adding more than 50 amps? 0 Yes lJ No Type of Use: Type of work: El New El Addition 0 Service Change El Remodel I21 Tenant Improvement 0 Low Voltage El Generator 0 Fire Alarm 0 Telecommunication El Temporary Service Property Served by: 171 Puget Sound Energy 0 Seattle City Light NV:Ten:nit CenteMpplications-Hanclouts \Permit Applications \PDFs\Electrical Permit Application Revised I-1-17.docx Revised: January 2017 bit Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 1/10/18 Print Name: Nicole Heavin Day Telephone: 425.249.2076 Mailing Address: PO BOX 5308 Lynnwood WA 98046 City W:\Pennit Cerate MPpliadons-Eiandou a\Permit Applications \PDFAElectrical Permit Application Revised 1-1.17.docx Revised: Jimmy 2017 bh State Zip Page 2 of 2 f`1 ;ash Register Receipt City of Tukwila` Receipt Number R13307 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY _ PAID $1,849.54 EL18-0039 Address: 4060 S 144TH ST Apn: 1523049013 $1,777.83 Credit Card Fee $51.78 Credit Card Fee R000.369.908.00.00 0.00 $51.78 ELECTRICAL $1,659.66 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,327.73 PLAN CHECK FEE R000.345.832.00.00 0.00 $331.93 TECHNOLOGY FEE $66.39 TECHNOLOGY FEE R000.322.900.04.00 0.00 $66.39 EL18-0040 Address: 4060 S 144TH ST Apn: 1523049013 $71.71 Credit Card Fee $2.09 Credit Card Fee R000.369.908.00.00 0.00 $2.09 ELECTRICAL $66.30 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $66.30 TECHNOLOGY FEE $3.32 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13307 R000.322.900.04.00 1 0.00 $3.32 $1,849.54 Date Paid: Thursday, January 11, 2018 Paid By: FRED WIRTZ Pay Method: CREDIT CARD 023035 Printed: Thursday, January 11, 2018 8:54 AM 1 of 1 rirI , SYSTEMS PER IT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0039 DATE: 01/11/18 PROJECT NAME: TSD - TECHNOLOGY CENTER SITE ADDRESS: 4060 S 144 ST X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: k) Building Division Public Works Fire Prevention Structural n Planning Division nPermit Coordinator 111 PRELIMINARY REVIEW: DATE: 01/16/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: DUE DATE: 02/13/18 Approved Corrections Required Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 INSPECTION RECORD Retain a copy with permit ER IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 438-9350 Project: i 9-1'64,1- Type of In pe ion: ii Address: 0 ' / T Date Called: Speciat Instructions: Date Wanted: a. . P. • Requester: Phone No: 7i73( Approved per applicable codes. Corrections required prior to approval. COMMENTS: nspe or: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98'188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: 1:6r 1 Type of Inspection: 1-1A1A1,- Date Called: Address: • . Special Instructions: 14 tif'11. rt e/7 Date Wanted: a.m it 22) p.m. Requester: ,..„..•^"" Phone No:7_06 1 s... --713c.--- Approved per applicable codes. Corrections required prior to approval. COMMENTS: A - LT -1.x- 6 EL - Inspector: Date: REINSPECTION1FEE REQUIRED. Prior to next inspection. fee ust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: —3 Type of Inspection: Address; (i 1 S • Li , Date Date Called: Special In uc ions: Date Wanted: 74 a. . Requester: Phone No: 2°C S-7/ 0(10 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 r Project : D A 7 ec,t1 -TR Type of I ection: t-.1 1 ,e'1 Addr ' & 0 S ,9ate Cal ed. e C -Log e.._ Li I' Special n u ons: Date Wanted: yn Requester: Phone No: plApproved per applicable codes. Corrections required prior to approval. COMMENTS: p_pervetS G6.1 t c ,ue,4-- wa (1 c;k> er A I /2q. -A ( C -Log e.._ Li I' Inspec Date: )14 RE SPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SYSTEM SOLUTIONS OF WA INC llorne Espanol ContaeL Safety & Health Claims & Insurance ClikWashington State Department of / Labor & Industries SYSTEM SOLUTIONS OF WA INC Owner or tradesperson Principals Wirtz, Fred, PRESIDENT JEFFERS, DANIELSON, SONN & AYL, AGENT WHETZEL, RICK L, PRESIDENT (End: 10/28/2013) Doing business as SYSTEM SOLUTIONS OF WA INC PO BOX 5308 LYNNWOOD, WA 98046 425-249-2076 SNOHOMISH County WA UBI No. Business type 603 039 116 Corporation Search L&I Page 1 of 2 A -Z IndeK Help MyL&I Workplace Rights Trades & Licensing License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. SYSTESW900PD Effective — expiration 10/01/2010— 10/01/2018 Designated administrator Wirtz, Fred J License type Electrical Administrator Bond DEVELOPERS SURETY & INDEM CO Bond account no. 276220C Active. Meets current requirements. License no. WIRTZFJ901C4 $4,000.00 Received by L&I Effective date 10/01/2010 09/29/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workerscomp premiums. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UB1=603039116&LIC=SYSTESW900PD&SAW= 2/28/2018 SYSTEM SOLUTIONS OF WA INC This company has multiple workers' comp aL..ounts. Active accounts L&I Account ID 277.588-00 Account is current. Doing business as SYSTEM SOLUTIONS OF WASHINGTON Estimated workers reported Quarter 4 of Year 2017 "11 to 20 Workers" L&I account contact T2 / CHRISTOPHER WASSON (360)902-6331 - Email: WASQ235@Ini.wa.gov Track this contractor 9 Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 0 Washington State Dept, of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603039116&LIC=SYSTESW900PD&SAW= 2/28/2018 ELECTRICAL LEGEND SY118OL PESCRIPTION SYMBOL DESCRIPTION 'DESCRIPTION ASBRY, hESCRIPTION AFF ABOVE FINISHED FLOOR LIGHTING OR POWER PANEL AElkFOR EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES SPECIFIC REQUIREMENTS. ALUMINUM M.C. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/21.C. MIN. EMT OR RIGID STEEL I INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. IIII1} e SPECIAL EQUIP CONNECTION WITH LIQUID TIGHT FLEX TO MATCH EQUIPMENT 0 MOTOR CONNECTION - — — - CONDUIT EXPOSED ❑' NON-FUSED DISCONNECT SWITCH CONDUIT CONDUIT CONCEALED IN WALL OR CEILING SPACE ONLY Ey FUSED DISCONNECT SWITCH CIRCUIT - -- CONDUIT UNDER GROUND OR FLOOR ®' COMBINATION FUSED DISCONNECT/MAGNETIC STARTER ----E— EXISTING CONDUIT 0' MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION —0 CONDUIT UP is ELECTRICAL CONTACTOR, TYPE AS INDICATED SC --® CONDUIT DOWN D SINGLE PUSH BUTTON SECONDARY DISTRIBUTION PNL E.C. CONDUIT STUB OUT WITH PLASTIC BUSHING SPECS e PUSH BUTTON SWITCH TO MATCH EQUIPMENT STARTER AND CONTROLLER EXHAUST FAN —■- BRANCH CIRCUIT HOME RUN 2 RED EMERGENCY SHUT-OFF PUSH BUTTON TEL --I' GROUNDING ELECTRODE PER CODES FIRE ALARM TEMP 4UV^V FLEXIBLE CONDUIT GENERAL CONTRACTOR FIRE ALARM PANEL THROUGH FAP GROUND FAULT INTERRUPTER TV TELEVISION IDE (J CODE SIZED JUNCTION BOX WITH COVER PLATE TYPICAL LCC LIGHTING CONTROL CENTER FIRE ALARM ANNUNCIATOR WIRE GUARD FAA LIGHTING WP WEATHER PROOF MDF 90 CORD REEL WITH 4PLEX OUTLET TRANSFORMER @ FIRE ALARM SMOKE DETECTOR 4* CEILING RECEPTACLE 0D FIRE ALARM SMOKE DETECTOR, DUCT TYPE 4A ELECTRICAL DEVICE AS INDICATED, A=ABOVE COUNTER 0 FIRE ALARM HEAT DETECTOR, RATE -OF -RISE TYPE (i DUPLEX RECEPTACLE OF FIRE ALARM HEAT DETECTOR, FIXED TEMPERATURE TYPE DUPLEX RECEPTACLE, TAMPER RESISTANT TYPE 'Tu FIRE ALARM SMOKE DETECTOR,PROJECTION BEAM TYPE TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE, TAMPER RESISTANT TYPE F FIRE ALARM CONNECTION, TYPE AS NOTED ON PLANS TWO DUPLEX RECEPTACLES IN COMMON BACK BOX AND UNDER COMMON PLATE CjS TAMPER SWITCH FIRE ALARM MONITORING CONNECTION (t SINGLE RECEPTACLE le FLOW SWITCH FIRE ALARM MONITORING CONNECTION STAGE LIGHTING CONTROL RECEPTACLE 8 FIRE ALARM AUDIO-VISUAL HORN/STROBE 111 , % FLUSH FLOOR BOX WITH DEVICES AS INDICATED A FIRE ALARM STROBE LIGHT [11] DUPLEX RECEPTACLE GFCI TYPE F FIRE ALARM MANUAL PULL STATION, D=DUAL ACTION TYPE. ;i DUPLEX RECEPTACLE SURGE PROTECTION TYPE D FIRE ALARM DOOR RELEASE CONNECTION 0 SPECIAL RECEPTACLE TYPE TO MATCH EQUIP SERVED, VERIFY REQUIREMENTS MULTI -GANG FLOOR BOX WITH DEVICES AS NOTED ON PLANS WITH 1"C.O. SPARE TO ADJACENT CEILING SPACE. OLS.. g FIRE ALARM COMBINATION FIRE/SMOKE DAMPER CEILING MOUNT FIRE ALARM AUDIO-VISUAL HORN/ STROBE 1► ,, �bI otvd SURFACE METAL RACEWAY WITH DEVICES A.S INDICATED. PROVIDE COMPLETE DEVICES, FITTINGS AND ASSEMBLIES. OC. SPACING OF' DEVICES ARE AS NOTED ON PLANS. ® BELL/BUZZER 6 SECURITY SYSTEM MOTION DETECTOR LIGHT FIXTURE, SEE SCHEDULE FOR TYPE LIGHT FIXTURE, WITH 'EL' INDICATES WITH EMERGENCY BATTERY PACK 4 ■ SECURITY SYSTEM CEILING MOUNT MOTION DETECTOR 360' SECURITY SYSTEM MAGNETIC CONTACT mmtm-I EL LIGHT FIXTURE, SEE SCHEDULE FOR TYPE Ii SECURITY SYSTEM KEY PAD 9 WALL MOUNTED LIGHT FIXTURE, SEE SCHEDULE FOR TYPE SECURITY SYSTEM CARD READER 0 LIGHT FIXTURE, SEE SCHEDULE FOR TYPE REQUEST TO EXIT SENSOR REX V' EXIT LIGHT WITH EGRESS LIGHTS AND EMERGENCY DRIVER DM SECURITY SYSTEM CAMERA LOCATION O EXIT LIGHT WITH EMERGENCY DRIVER 0 LOCK DOWN BUTTON (SECURITY/INTERCOM CONNECTIONS) D TYPICAL LIGHTING FIXTURE DESIGNATION, SEE SCHEDULE FOR TYPE INTERCOM CONSOLE IC $ SINGLE POLE SWITCH INTERCOM DIGITAL DISPLAY DD THREE WAY SWITCH V INTERCOM CALL SWITCH V LOW VOLTAGE VACANCY SENSOR SWITCH WITH DIMMING CONTROL 0 INTERCOM HANDSET, ADM=ADMIN TYPE WITH DISPLAY D=DESK TYPE V LOW VOLTAGE VACANCY SENSOR SWITCH 0 INTERCOM WALL OR CEILING SPEAKER V LOW VOLTAGE SWITCH 6WP INTERCOM WEATHERPROOF OUTDOOR HORN/SPEAKER t MOMENTARY CONTACT SWITCH i PILOT LIGHTED SWITCH MASTER CLOCK MC t KEY OPERATED SWITCH Q ANALOG CLOCK MANUAL DIMMER SWITCH 13 DIGITAL CLOCK C WALL MOUNT OCCUPANCY SENSORSWITCH ANALOG CLOCK/SPEAKER COMBINATION :1? ® CEILING MOUNTED PHOTO CELL/PHOTO SENSOR E DIGITAL CLOCK/SPEAKER COMBINATION 9 LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (WALL MOUNT) V VOLUME CONTROL Ett LIGHTING CONTROL OCCUPANCY SENSOR DUAL TECHNOLOGY (CEILING MOUNT) ® VIDEO PROJECTOR OUTLET ,; • LIGHTING ROOM CONTROLLER SOUND SYSTEM AMPLIFIER AMP SWITCHED RECEPTACLE CONTROLLER X SOUND SYSTEM SPEAKER Q THERMOSTAT Q MICROPHONE JACK ® SOLENOID VALVE 8) SOUND SYSTEM AUXILIARY INPUT AQUASTAT BY MC, CONNECTIONS TO CIRC PUMP BY EC e TV OUTLET 1 TELECOMMUNICATIONS - OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) # = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (I.E 1,2,3, ETC.) WAP ADJACENT TO SYMBOL = WIRELESS ACCESS POINT TELECOM CONNECTION CCTV ADJACENT TO SYMBOL = CLOSED CIRCUIT TV TELECOM CONNECTION ey TELEVISION AUDIO-VISUAL INPUT JACK TELECOMMUNICATIONS - FLOOR OUTLET DEVICE (UTP RJ45 UNLESS OTHERWISE NOTED) # = NUMBER INSIDE SYMBOL INDICATES THE QUANTITY OF TELECOMMUNICATION CABLE DROPS AND JACKS AT EACH OUTLET LOCATION. (LE. 1,2,3, ETC.) DZ1 DAYLIGHT ZONE 1 (), DAYLIGHT ZONE 2 (DZ2), TOPLIGHT ZONE (TZ) AS REQUIRED BY WASHINGTON STATE ENERGY CODE (SEE LIGHTING PLANS) HDML AV OUTLET (LOW) ADJACENT TELECOM OUTLET HDMI GROMMET PLATE (HIGH) ADJACENT WALL PROJECTOR AVL m SEF".!, T E REC U!EEJ C : E Mechanical ❑ lectrical L�Jf Iumbing tB Gas Piping City of Tukwila BUILDING DIVISION ADPL IANCES KEY LETTER E.C. TO PROVIDE RECEPTACLE FOR APPLIANCE AS SHOWN. VERIFY LOCATION WITH ARCHITECT. CM : COFFEE MAKER CP : COPIER DW : DISHWASHER DY : DRYER FZR : FREEZER GD : GARBAGE DISPOSAL. H/HD : HAND OR HAIR DRYER IH : INSTANT HOT WATER HEATER IM : ICE MAKER MW : MICROWAVE REF : REFRIGERATOR VM : VENDING MACHINE WH : WASHER S 13911) St S 1390 St en 4tlth Si foster emortsl Part/ S1»1stSt enter ofTukwile0 St Thomas Catholic Church.Tukwila S144tit St Foster HIQh School 0 Faster Library Q N hSt a S144thSt S14AthSt. G n S 144th St $ 144 th St N. S':1 FI'L7 PROJEC`0 h'st..00ATIoNti Shell 0 Pe r° "M'",. WE6 /00 J Plan review to errors and Approval of corgi°:;::... z doe :. ents does nc, . _"C::: 3 the violation of ar: :sed G:.'a or ordinance. of approved Fie:J � ; o coy tditions is By: Date: -o - it -,f ; :kwila ��i1 MK_ :2 DIVISION VICINITY MAP SCALE: NONE REVISIONS No changes shall ho made to the scope of work without prior approval of Tul;t•_lil:a Bu?Ir:ing Division. NOTE.: i-t2vi or,:, +,.tifill r iuir€)a re t.v plan submtttai and m::1/ ir• _ ad: ;?lana! ran rev'oty GENERAL. REQUIREMENTS ALL. SHEETS 1. E.C. TO PROVIDE ALL MATERIAL AND LABOR FOR MAINTAINING FIRE RATING OF WALLS IN AREAS WHERE ELECTRICAL DEVICES PENETRATE IN OR THROUGH. SEE ARCHITECTURAL DRAWING FOR FIRE WALL LOCATION. 2. E.C. TO PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES. COORDINATE LOCATION AND CONNECTIONS WITH M.C. 3. SEE ARCHITECTURAL DRAWING FOR LOCATION OF ELECTRICAL DEVICES LOCATED ON EXTERIOR OF BUILDING. ALL EXTERIOR BUILDING MOUNTED DEVICES (EXCEPT FIRE ALARM DEVICES) SHALL HAVE FACTORY FINISH OR PAINT TO MATCH BUILDING SURFACE. 4. ALL FLUSH MOUNT EQUIPMENT, CABINET AND PANEL BOARD SHALL HAVE FACTORY TYPE FLUSH MOUNT TRIM KIT. FOR COMPLETE INSTALLATION. 5. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALTERNATE BID NUMBERS AND CORRESPONDING AREAS AND RELATED ELECTRICAL WORK TO BE PROVIDED. E.C. TO INCLUDE IN BASE BID, ALL ELECTRICAL WORK THAT IS REQUIRED FOR BASE BID AND IN THE ASSOCIATED AREAS OF CONSTRUCTION IF ANY OF THE ALTERNATE BIDS ARE TAKEN OR ACCEPTED. 6. REFER TO PLANS FOR LOCATION OF EMERGENCY LIGHTING BATTERY PACK AND FIXTURES. 7. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND. 8. E.C. TO VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS AND COUNTER HEIGHTS PRIOR TO OUTLET ROUGH -IN. OUTLETS LOCATED ABOVE COUNTER ARE TO BE INSTALLED TO CENTER LINE ABOVE COUNTER TOP OF BACK SPLASH. AS DIRECTED OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH ARCH/ENG. OF ANY LOCATION THAT WILL NOT ACCOMMODATE MOUNTING HEIGHT, 9. ALL EXTERIOR EQUIPMENT, PANELS OR DEVICES SHALL BE WEATHERPROOF AND WITH NEMA -3R ENCLOSURE TYPE. 10. ELECTRICAL CONTRACTOR TO VERIFY WITH SERVING UTILITY COMPANIES FOR ALL UTILITY CHARGES AND TO INCLUDE SUCH CHARGES IN BID. 11. CIRCUITS, WIRE SIZE AND WIRE HASH MARKS ARE SHOWN FOR CIRCUIT CLARITY, BUT MAY NOT NECESSARILY REPRESENT THE COMPLETE WIRING COUNTS AND MINIMUM SIZES FOR CONNECTING THE CIRCUITS SHOWN. E.C. TO INCLUDE IN THE BID, ALL THE REQUIRED WIRING SIZES` AND NUMBER OF CONDUCTORS IN ORDER TO INSTALL ALL CIRCUITS SHOWN AS NECESSARY. 12. ALL LIGHT SWITCHES SHALL BE LOCATED AT STRIKE SIDE OF DOOR SWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR DOOR LOCATIONS. SWITCHES THAT CAN NOT BE LOCATED ON STRIKE SIDE OF DOOR BECAUSE OF STRUCTURAL MEMBERS SHALL. BE AS DIRECTED IN FIELD. 13. DO NOT INSTALL ANY FLUSH WALL OUTLET BACK TO BACK. A MINIMUM OF 24" SEPARATION IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL. 14. INSTALLATION OF NEW UNDERGROUND FEEDERS SERVING POWER, INTERCOM, TELEPHONE, FIRE ALARM, AND T.V. SHALL 'INCLUDE CUTTING, PATCHING, HAND DIGGING, ETC. DO NOT CUT OR DAMAGE ANY EXISTING UTILITIES, STRUCTURAL MEMBERS OR BUILDING FOUNDATIONS. VERIFY ROUTE AND REMOVE ALL EXISTING FLOOR TILE IN AREAS THAT ARE TO BE CUT. ANY DAMAGE TO EXISTING UTILITIES OR BUILDING STRUCTURE SHALL BE REPAIRED TO OWNER'S SATISFACTION AT THE CONTRACTORS EXPENSE. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO WORK. 15. ALL ONE LINES, RISERS, AND CONDUIT ROUTING ARE SCHEMATICS AND ARE NOT SHOWING EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT. WHERE INDICATED ON DRAWINGS ALL JUNCTION BOXES AND PULL BOXES ARE MINIMUM REQUIREMENTS. ELECTRICAL CONTRACTOR TO PROVIDE ALL OTHER FITTINGS AND PULL BOXES OF ADEQUATE SIZE IN THE RACEWAY SYSTEM WHEREVER NECESSARY OR REQUIRED BY NATIONAL ELECTRICAL CODE. PROVIDE EXPANSION JOINT FITTINGS FOR CONDUITS PASSING THROUGH NEW OR EXISTING EXPANSION JOINTS INSTALLED BETWEEN BUILDINGS. VERIFY EXACT LOCATIONS AND DETAILS OF EXPANSION JOINTS PRIOR TO WORK: COORDINATE ALL CONDUIT ROUTING, PULL BOX AND EQUIPMENT LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. 16. E.C. TO PROVIDE 60 WATT LAMPS FOR .ALL RANGE HOODS. 17. NO ELECTRICAL CONDUITS ARE ALLOWED TO BE RUN IN ANY FLOOR SLABS. CONDUITS SERVING DEVICE LOCATED IN FLOOR SHALL BE SERVED FROM BELOW AND PASS THROUGH THE FLOOR SLAB. GENERAL NOTES IN AREAS WHERE ROOF STRUCTURE/DECKING IS EXPOSED E.C. SHALL PROVIDE ALTERNATE MEANS FOR DEVICE ATTACHMENT. E.C. SHALL PROVIDE UNISTRUT OR OTHER APPROVED METHODS FOR ATTACHMENT BETWEEN TRUSSES OR BEAMS. IN NO CASE SHALL ANY DEVICE BE MOUNTED ON THE EXPOSED UNDERSIDE OF THE ROOF DECK WITHOUT PRIOR APPROVAL FROM THE ARCH/MANUFACTURER. ALL SUPPORT ITEMS SHALL BE PAINTED TO MATCH SURROUNDING SURFACE. ALL MEANS OF SUPPORT/ATTACHMENT SHALL BE APPROVED BY THE ARCH. ELECTRIC/AL SHEET L IST AINBIREVIATION (ABM) BEO.02 ABSRv. 'DESCRIPTION ASBRY, hESCRIPTION AFF ABOVE FINISHED FLOOR MDP MAIN DISTRIBUTION PANEL AL ALUMINUM M.C. MECHANICAL CONTRACTOR BB BASEBOARD HEATER MLO MAIN LUG ONLY BKR BREAKER MH METAL HALIDE C CONDUIT OL OVER LOAD CKT CIRCUIT PNL PANEL C.O. CONDUIT AND PULL WIRE ONLY RH RANGE HOOD COMM COMMUNICATION SB SCORE BOARD Cu COPPER SC SHOT CLOCK DH DUCT HEATER SDP SECONDARY DISTRIBUTION PNL E.C. ELECTRICAL CONTRACTOR SPECS SPECIFICATIONS EF EXHAUST FAN SW SWITCH EQP EQUIPMENT TEL TELEPHONE FA FIRE ALARM TEMP TEMPERATURE G.C. GENERAL CONTRACTOR THRU THROUGH GFI GROUND FAULT INTERRUPTER TV TELEVISION IDE INTERMEDIATEE DISTRIBUTION FRAM TYp TYPICAL LCC LIGHTING CONTROL CENTER WG WIRE GUARD LTG LIGHTING WP WEATHER PROOF MDF RAIN DISTRIBUTION FRAME XFMR TRANSFORMER ADPL IANCES KEY LETTER E.C. TO PROVIDE RECEPTACLE FOR APPLIANCE AS SHOWN. VERIFY LOCATION WITH ARCHITECT. CM : COFFEE MAKER CP : COPIER DW : DISHWASHER DY : DRYER FZR : FREEZER GD : GARBAGE DISPOSAL. H/HD : HAND OR HAIR DRYER IH : INSTANT HOT WATER HEATER IM : ICE MAKER MW : MICROWAVE REF : REFRIGERATOR VM : VENDING MACHINE WH : WASHER S 13911) St S 1390 St en 4tlth Si foster emortsl Part/ S1»1stSt enter ofTukwile0 St Thomas Catholic Church.Tukwila S144tit St Foster HIQh School 0 Faster Library Q N hSt a S144thSt S14AthSt. G n S 144th St $ 144 th St N. S':1 FI'L7 PROJEC`0 h'st..00ATIoNti Shell 0 Pe r° "M'",. WE6 /00 J Plan review to errors and Approval of corgi°:;::... z doe :. ents does nc, . _"C::: 3 the violation of ar: :sed G:.'a or ordinance. of approved Fie:J � ; o coy tditions is By: Date: -o - it -,f ; :kwila ��i1 MK_ :2 DIVISION VICINITY MAP SCALE: NONE REVISIONS No changes shall ho made to the scope of work without prior approval of Tul;t•_lil:a Bu?Ir:ing Division. NOTE.: i-t2vi or,:, +,.tifill r iuir€)a re t.v plan submtttai and m::1/ ir• _ ad: ;?lana! ran rev'oty GENERAL. REQUIREMENTS ALL. SHEETS 1. E.C. TO PROVIDE ALL MATERIAL AND LABOR FOR MAINTAINING FIRE RATING OF WALLS IN AREAS WHERE ELECTRICAL DEVICES PENETRATE IN OR THROUGH. SEE ARCHITECTURAL DRAWING FOR FIRE WALL LOCATION. 2. E.C. TO PROVIDE ELECTRICAL CONNECTION FOR ALL FAN SPEED SWITCHES. COORDINATE LOCATION AND CONNECTIONS WITH M.C. 3. SEE ARCHITECTURAL DRAWING FOR LOCATION OF ELECTRICAL DEVICES LOCATED ON EXTERIOR OF BUILDING. ALL EXTERIOR BUILDING MOUNTED DEVICES (EXCEPT FIRE ALARM DEVICES) SHALL HAVE FACTORY FINISH OR PAINT TO MATCH BUILDING SURFACE. 4. ALL FLUSH MOUNT EQUIPMENT, CABINET AND PANEL BOARD SHALL HAVE FACTORY TYPE FLUSH MOUNT TRIM KIT. FOR COMPLETE INSTALLATION. 5. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ALTERNATE BID NUMBERS AND CORRESPONDING AREAS AND RELATED ELECTRICAL WORK TO BE PROVIDED. E.C. TO INCLUDE IN BASE BID, ALL ELECTRICAL WORK THAT IS REQUIRED FOR BASE BID AND IN THE ASSOCIATED AREAS OF CONSTRUCTION IF ANY OF THE ALTERNATE BIDS ARE TAKEN OR ACCEPTED. 6. REFER TO PLANS FOR LOCATION OF EMERGENCY LIGHTING BATTERY PACK AND FIXTURES. 7. PROVIDE COMPLETE WORK FOR REQUIREMENTS AS DESCRIBED ON LEGEND. 8. E.C. TO VERIFY WITH CABINET INSTALLER FOR ALL CABINET LOCATIONS, DIMENSIONS AND COUNTER HEIGHTS PRIOR TO OUTLET ROUGH -IN. OUTLETS LOCATED ABOVE COUNTER ARE TO BE INSTALLED TO CENTER LINE ABOVE COUNTER TOP OF BACK SPLASH. AS DIRECTED OR INDICATED IN SPECIFICATIONS. VERIFY HEIGHT WITH ARCH/ENG. OF ANY LOCATION THAT WILL NOT ACCOMMODATE MOUNTING HEIGHT, 9. ALL EXTERIOR EQUIPMENT, PANELS OR DEVICES SHALL BE WEATHERPROOF AND WITH NEMA -3R ENCLOSURE TYPE. 10. ELECTRICAL CONTRACTOR TO VERIFY WITH SERVING UTILITY COMPANIES FOR ALL UTILITY CHARGES AND TO INCLUDE SUCH CHARGES IN BID. 11. CIRCUITS, WIRE SIZE AND WIRE HASH MARKS ARE SHOWN FOR CIRCUIT CLARITY, BUT MAY NOT NECESSARILY REPRESENT THE COMPLETE WIRING COUNTS AND MINIMUM SIZES FOR CONNECTING THE CIRCUITS SHOWN. E.C. TO INCLUDE IN THE BID, ALL THE REQUIRED WIRING SIZES` AND NUMBER OF CONDUCTORS IN ORDER TO INSTALL ALL CIRCUITS SHOWN AS NECESSARY. 12. ALL LIGHT SWITCHES SHALL BE LOCATED AT STRIKE SIDE OF DOOR SWING. REFER TO ARCHITECTURAL FLOOR PLANS FOR DOOR LOCATIONS. SWITCHES THAT CAN NOT BE LOCATED ON STRIKE SIDE OF DOOR BECAUSE OF STRUCTURAL MEMBERS SHALL. BE AS DIRECTED IN FIELD. 13. DO NOT INSTALL ANY FLUSH WALL OUTLET BACK TO BACK. A MINIMUM OF 24" SEPARATION IS REQUIRED BETWEEN ANY OUTLET INSTALLED ON FIRE RATED WALL. 14. INSTALLATION OF NEW UNDERGROUND FEEDERS SERVING POWER, INTERCOM, TELEPHONE, FIRE ALARM, AND T.V. SHALL 'INCLUDE CUTTING, PATCHING, HAND DIGGING, ETC. DO NOT CUT OR DAMAGE ANY EXISTING UTILITIES, STRUCTURAL MEMBERS OR BUILDING FOUNDATIONS. VERIFY ROUTE AND REMOVE ALL EXISTING FLOOR TILE IN AREAS THAT ARE TO BE CUT. ANY DAMAGE TO EXISTING UTILITIES OR BUILDING STRUCTURE SHALL BE REPAIRED TO OWNER'S SATISFACTION AT THE CONTRACTORS EXPENSE. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO WORK. 15. ALL ONE LINES, RISERS, AND CONDUIT ROUTING ARE SCHEMATICS AND ARE NOT SHOWING EXACT PHYSICAL ARRANGEMENT OF EQUIPMENT. WHERE INDICATED ON DRAWINGS ALL JUNCTION BOXES AND PULL BOXES ARE MINIMUM REQUIREMENTS. ELECTRICAL CONTRACTOR TO PROVIDE ALL OTHER FITTINGS AND PULL BOXES OF ADEQUATE SIZE IN THE RACEWAY SYSTEM WHEREVER NECESSARY OR REQUIRED BY NATIONAL ELECTRICAL CODE. PROVIDE EXPANSION JOINT FITTINGS FOR CONDUITS PASSING THROUGH NEW OR EXISTING EXPANSION JOINTS INSTALLED BETWEEN BUILDINGS. VERIFY EXACT LOCATIONS AND DETAILS OF EXPANSION JOINTS PRIOR TO WORK: COORDINATE ALL CONDUIT ROUTING, PULL BOX AND EQUIPMENT LOCATIONS WITH OTHER TRADES TO AVOID CONFLICTS OF EQUIPMENT INSTALLATIONS. ALL EMPTY CONDUITS SHALL HAVE PULL WIRES. 16. E.C. TO PROVIDE 60 WATT LAMPS FOR .ALL RANGE HOODS. 17. NO ELECTRICAL CONDUITS ARE ALLOWED TO BE RUN IN ANY FLOOR SLABS. CONDUITS SERVING DEVICE LOCATED IN FLOOR SHALL BE SERVED FROM BELOW AND PASS THROUGH THE FLOOR SLAB. GENERAL NOTES IN AREAS WHERE ROOF STRUCTURE/DECKING IS EXPOSED E.C. SHALL PROVIDE ALTERNATE MEANS FOR DEVICE ATTACHMENT. E.C. SHALL PROVIDE UNISTRUT OR OTHER APPROVED METHODS FOR ATTACHMENT BETWEEN TRUSSES OR BEAMS. IN NO CASE SHALL ANY DEVICE BE MOUNTED ON THE EXPOSED UNDERSIDE OF THE ROOF DECK WITHOUT PRIOR APPROVAL FROM THE ARCH/MANUFACTURER. ALL SUPPORT ITEMS SHALL BE PAINTED TO MATCH SURROUNDING SURFACE. ALL MEANS OF SUPPORT/ATTACHMENT SHALL BE APPROVED BY THE ARCH. ELECTRIC/AL SHEET L IST 6E0.01 ELECTRICAL LEGEND, NOTES AND SCHEDULES BEO.02 WSEC FORM BED1.01 DEMOLITION PLAN - POWER & LIGHTING I CVeAOeII 1=_op 8E2.01 FLOOR PLAN - POWER & LIGHTING COMPLIANCE WI1 NFPA 70 - NEC 8E3.01 FLOOR PLAN - SYSTEMS BE3.02 FLOOR PLAN - FIRE ALARM FSM4BS FLFL 375DN 625UP 35K 1C UNV LD1 C24 WH 6E5.01 POWER ONE -LINE DIAGRAM FEB 0 1 2013 BE8.01 FIRE ALARM ONE -LINE DIAGRAM4)W 1'X4' LAY -IN LED 8E8.02 SYSTEMS ONE -LINE DIAGRAM City of Tukwila LED 43 OFFICES, STORAGE S1 SURFACE MOUNT LED 1X4 N CITY OF TUKWILA JAN 11 2018 LIGHT FIXTURE SCHEDULE PERMIT CENTER TYPE DESCRIPTION MANUFACTURER LAMP INPUT WATTS Notes NAME CATALOG NUMBER QTY. TYPE P1 LINEAR DIRECT/INDIRECT FOCAL POINT FSM4BS FLFL 375DN 625UP 35K 1C UNV LD1 C24 WH INC. LED 44 OFFICE R1 1'X4' LAY -IN LED FOCAL POINT FEQ2 14 AC 4000L 35K 1C UNV LD1 G EM WH INC. LED 43 OFFICES, STORAGE S1 SURFACE MOUNT LED 1X4 LITHONIA LIGHTING FEM L48 3000LM IMAFL MD MVOLT GZ10 40K 80CRI INC. LED 23 MDF ROOM GENERAL NOTES: SLI 003 9 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 111111111011111111111 tvolt TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com w Z 0CJ< W o0 cs� ao (1) Cid Z 0-1 W2 0 O 12 O 0- 0 w P‹. WW REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title ELECTRICAL LEGEND AND NOTES Drawing Number BE0.01 RIn nl TM i PrtPkIrl nwr_ T CfPVRI[2HT fA 2nu% N41_LUNA ARCHITFCTS INCA f.t>, },# .J Y d& .4rci3r.iU tri 1 `.t.� Y2l3�;fi'}`fd1�p;jp tt4'".k;,:., `k45+'S`.v5�k',�ix'YuYayP�liVY`5WW)�j['•;. Checklist •Rntt'�?5{S}tiLTG-CHK r l r, i ,r Ch l i Pg.LI htin .,,Moto �andxfE ectrical Pe m t eck st3 Lighting ie : r} J'1f t rt .amu.. ler 54; 9 »f : r, 'al."..,n. ,n,p, •,rr .no -p +r. r1. , r, nn r, „r n u r ,j11 rt n ,c � ... , „ • nr ,. n, , LTG . ., ., ,,.a:•, ,U, ..<,.. tri ..aalf.„ n, •,n ,. c, ,, Project Title: Tukwila School District - Tech & Maintenance Building (Date 7/17/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical Washington State Energy Cade, Commercial Provisions. requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Component Yee C405.4.1 0405.4.1 0405.4.2 Total connected interior lighting power Include all luminaires in, lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and incompliance forms; indicate the exception applied;_ 13E2.01 BE2.01 Yes Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently NA NA For all lighting fixtures, indicate lighting control method on plans for spaces' and lighting zone(s) served, or exception taken Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) BE2.01 Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, Indicate In lighting fixture schedule If lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this efficacy rating (min 95% to comply with option). Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves BE2.01 Lighting Power Calculation - Indicate compliance path taken Yea NA C405.4.2.1 Building Area Method Complete required compliance forms - proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yee Yea 0405.4.2.2 Space -By -Space Method Complete required compliance forms - total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable 13E0.02 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies NA C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage Is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; 1. Occupancy sensor controls - warehouses Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form -proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed '4"•M"LaI h In Motors.. ... r ... ita.e., nd, a.3 r En. Sw r h„i i ei cr.t.. k3k} lIsYtt Ia)ct.., t:,.. ri�f3.. lcryi nra P r C7 Pg. ,c>: ,c . (4Y4: � TCHK Y,. LTG-CHK .., .,cup 0405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with'daylight sensincontrols and the exception(s)) that apply; Indicate on plans the lighting load reduction method continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power, ProjectTitle: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 ifor t e lig lighting, motor,and electrical The following information is necessary to check a permit application with h g g, Washington State Energy Code, Commercial Provisions. requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS C405.2.5 - Items 1&2 NA 0405.6 Electrical trenfortners Include electrical transformer schedule on electrical plans; Indicate transformer size, efficiency, or exception taken Lighting ghting, rMotor NA C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter Yes C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied BM0.02 Component NA C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more 0405.2.5- Item 3 Hotel/motel guest rooms NA C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.2.5 Item 4 Supplemental task lighting NA C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive C405.2.5 - Item 5 Lightingfornon-visual applications Yes C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space In which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control BE2.01 1E2.01 Lighting equipment for sale or demonstration If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist Z htin9 Lighting i•r F Motor r, b ki } fi}a ..,, f . �i Electrical„ fF f N ft3 i Fi F i{ Y Y ru Permit G. h erawck.,:lisA,i.t Pg �.�1 TG -CHK : Project Title: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 The following Washington information is necessary to check a State Energy Code, Commercial Provisions. permit application for compliance with the lighting, motor, and electrical requirements in the Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in I Documents Building Department Notes LIGHTING CONTROLS Yes 0405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces' and lighting zone(s) served, or exception taken BE2.01 NA C405,2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA 0405:1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yee C405.2.3 0405.2.1.1 0405,2,2.2 0405.2:4 0405.2.5 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves BE2.01 Yea C405.2.2.1 0405.2.2,2 C405.2.3 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls 2E2.01 Yee 0405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; 0E2.01 Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies BE2.01 Yea C405.2.1 C405.2.1:1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; 0E2.01 Indicate whether occupancy sensor controls are configured to be manual -on automatic atic 50% -on or serve a space i ' m Pae e I Bible for automatic 100% -on per exception BE2.01 NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used NA 0405.2:2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq, ft. NAFor C405.2.4.2 0405.2:4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft.; small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA 0405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with'daylight sensincontrols and the exception(s)) that apply; Indicate on plans the lighting load reduction method continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power, Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls - Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section P PP 9 9 NA C405.2.5 - Items 1&2 Display and accent lighting 9 Indicate on plans that display and accent lighting, and display case l/ lighting are controlled independently from both general 9 9 area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting ghting, rMotor y�s and fElectrlcal £ ;{.• PermitfiCheckhst Pg ' S t 2, xz LTG :CHK Project Title: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes NA 0405.2.5- Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NA C405.2.5 Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy control for supplemental task lighting, including under -shelf or under -cabinet lighting NA C405.2.5 - Item 5 Lightingfornon-visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control Yes 0405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control 13E2.01 BATTERY BACKED NA 0E2.01 NA 0405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method. control sequence, and locations served; For building fagade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA 0405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures hake efficacy greater than 80 lumens or, are controlled by motion sensor, or are exempt lighting per C405.5.2 NA 0405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% NA C406.4 Enhanced digital lighting controls g g To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) NA 0405,13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; EXEMPT, < 20KW Identify applicable commissioning documentation requirements per Section 0408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Interiori� htinY �,4 � ra5<ir*',l.= ,S a 8: ac S aceM ethod � �r.t s LTG INT SPACE Protect Title: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 Calculation Area NO'E 9 O New Construction o Addition stand alone o Addition 0 Clear + existing ® Spaces where < 50% of 0 Spaces where z 50% of o Spaces where the Use luminaires are replaced luminaires are replaced is changing (C505) LPA Calculation Type fl Standard O Additional Efficiency Package Option 0406.3 Reduced Interior Lighting To comply with C406.3, the Proposed LPD shall be 25% tower than the Target LPA. Refer to 0406.3 for additional requirements. 0 Clear For Building Department Use Maximum Allowed Lighting Wattage NOTE 1 Location (plan#, room #) Space Type Ceiling Height 2 Gross Interior Area in 112 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Break Room. 112 Lounge&bieak' a Training 1 Store Office 11 19 Office:; Storage roor e:.Enclos 0 0 Office 116 Office: Enc 1 0 Office 115 Office: Enclosed 1 0 0; 9 809 Total Area Retail Display Allowance from LTG -INT -DISPLAY Enter Total Existing Lighting Watts (prior to Alteration) Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Allowed Watts Proposed Lighting Wattage "OTE 71 Fi 716 Location (plan#, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE 7 Type RI, LED, 0-10V Type P1, LED, 0-10V Type S1, LED, 0-10V 6 6 1 43 44 23 Proposed Retail Display Lighting from LTG -INT -DISPLAY Total Proposed Watts mar not exceed Total Allowed Watts for interior Lighting Total Proposed Watts Watts Proposed. lye 264 23 545 Interior. Lighting Power Allowance COMPLIES Note 1- Ust all unique spar.re types per Table 0405.4.2(2) 2(2) that occur in the project scope. Select sace type category ryAer from dropdowmenu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table 0405.4.2(2), Footnotes d thru f, Note 3 - List all proposed ighting fixtures including exempt lighting equipment end existing -to -remain fixtures. Note 4 For proposed Fixture Description, Indicate fixture type, lamp type (e,g. T-8), number of lamps in the fixture, and ballast type (if included). For track fighting, 71st the length of the track (In feet) In addition to the fixture, lamp, and ballast Information, Note 5- For lighting equipment e 1gtbfe for exemption C405.4.1 note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer orother approved source. For luminaires with screwHn lamps, enter the manufacturer's listed maximum Input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer, For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, cr enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowence is independent of the Maximum Allowed Lighting Wattage, Note 9 - Calculation Area Details: a. Lighting fixture; In a building addition may comply es a stand alone protect, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to 0502.1. b. For alterations and building additions, provlde Space Types and gross interior areas fn the Maximum Allowed Lighting Wattage tabla if a building additicn viii comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures Wil be replaced, provide total existing lighting wattage (prior to alteration) In the space provided In the Maximum Allowed Lighting Wattage table. LightingSummar' Y, 11 a r' r4 • I> I. ,,Ir ,1• - . 101 G • 1 N u, I J, n V• •(41.1(',10 I LGT= ,....suns V 64.0..“..1IY Project Info Compliance forms do not require a password to use. Instructional and calculating cells are wite- protected. Project Title: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Company Name: Tukwila School District Company Address: 4640 S 144th St Applicant Name: David Henning Applicant Phone: 263.4723300 Applicant Email: dph@treswestcom For Building Department Use Project Description ❑ New Building 0 Addition Alteration Ei Plans Included IncludePROJ-SUM form (included in envelope; forms workbook) with lighting complliance forms. Building Additions Refer to Section C502.2.6 foradditiona! requirements. Compliance Method Interior lighting i Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project 0 Lighting systems in addition arecombined with existing building lighting systems to demonstrate compliance ❑ I ❑ Addition is combined with existing: For Interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior ighting'fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. if project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some .spaces, and 50% or more of the fixtures am replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional' requirements. Al! alteration lighting controls shall be commissioned per C406.3. ❑ No changes are being made to the interior or exterior lighting and existing a systems 1 g sp ce uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced Less than 50% of existing are replaced El Lamp and/or ballast replacement only existing total wattage not increased 50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C4054.2 and 0405.5 2. include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration, Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces and parking garages, and total installed wattage for exterior luminaires. Lighting Controls ! Interior lighting New wiring installed to serve added i fixtures and/or fixtures relocated to newt circuit(s) Parking garage Exterior lighting New or moved lighting panel Interior space is reconfigured luminaires unchanged or relocated oniy/ ❑ New wiring or circuit - For, interior lighting, provide required manual controls per 0405.2.3,occupancy sensor controls per 0405,2.1, daylight responsive controls per C405.24 and application specific lighting controls per 0405.2.5. For exterior lighting, provide required controls per 0405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and PA ring automatic time switch controls per 04052.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per 0405.2.5 do not apply to reconfigured spaces. Change of Space Use 1 L htln u mar •re , a, r e. Jp O Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade ta the current Code in Proposed Lighting' Wattage table in LTG4NT-BLD or LTG -INT -SPACE form. cont: r eto J1• r,1 , e,,,, •1„ L T- M G__.SU I4 Project Title: Tukwila School District - Tech & Maintenance Building Date 7/17/2017 Interior Lighting e System p Description Briefly describe interior lighting system type and features. New LED fixtures and controls for added spaces. Interior Lighting Power Allowance Method 0 Building Area Method p Space -by -space Method Select method used In project: Interior Lighting Controls ea All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls. To comply wth C406.4, no less than 90% of the total installed lntenor lighting power shall comply with th required controls r C4 4 per O6. . Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: 43, No Dwelling 0 0405,2 thru C405.5 Commercial Lighting Controls and LPA Units 0 C406.3 High Efficacy Lighting O R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential provisions in lieu of WSEC Commerical provisions. Exterior Lighting System Description Briefly; describe exterior lighting system type and features. N/A sIC. FPA70•N- FEB 01 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 112018 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 Itet TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253,472.3300 www.treswest.com W rrn w ode oV z 0 U ,04t( 1.1. V CO CO c0 t3) co CO e - CO REVISION DATE Design: Drawn: Checked: Project No. DPH DPH DPH 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title WSEC FORM Drawing Number • 0.02 COPYR1014T to 71115 Mil 110A ARCHITFCTS IHC RF0.02 WSFC FORM_nWG FLAN NOTES c in, 16 EXISTING LIGHT SWITCHES TO REMAIN. THESE SWITCHES CURRENTLY CONTROL ALL LIGHTING IN MAIN OPEN AREAS. ELECTRICAL 111 C4D A/38 WORK ROOM ENTRY LOBBY 100 A/29 J L1 MEN'S TOILET 101 STORAGE 104 WOMEN'S TOILET TOILET II A/20 102 TRAINING ROOM 103 A/25 A/23 A/25 P DEMOLITION FLOOR P SCALE: 1/8" = 1"-0" AN -ELECTRICAL FLAN NOTES cal 0 CAREFULLY DISCONNECT EXISTING EXIT/EGRESS WALL MOUNTED FIXTURE AND RELOCATE AS INDICATED ON SHEET BE2.01. 10 DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE MAINTAIN JUNCTION BOX AND CIRCUIT WIRING TO CONNECT TO NEW FIXTURES TO BE PROVIDED IN THIS LOCATION. 11 DISCONNECT AND REMOVE EXISTING LIGHT FIXTURE, MAINTAIN CIRCUIT CONTINUITY TO ALL OTHER FIXTURES ON THESE CIRCUITS. 12 EXISTING FIXTURE TO REMAIN. REMOVE EXISTING SWITCH—LEG CONTROLLING THIS FIXTURE AND RECONNECT TO NEW SWITCH. SEE SHEET BE2.01 FOR NEW SWITCH LOCATION. 13 EXISTING FIXTURE TO REMAIN. REMOVE EXISTING CIRCUIT AND SWITCH CONNECTION AND RE—CIRCUIT AND SWITCH AS INDICATED ON SHEET BE2.O1. 14 REMOVE EXISTING SURFACE MOUNTED COMBO SWITCH/ RECEPTACLE AND ALL CONDUIT SURFACE MOUNT WIREMOLD, AND WIRING TO NEXT ACTIVE DEVICE OR JUNCTION BOX. OTHER EXISTING DEVICES ON THIS CIRCUIT ARE TO REMAIN FUNCTIONAL. 15 THE THREE EXISTING SURFACE MOUNTED RECEPTACLES MOUNTED ABOVE COUNTER SHALL REMAIN AND BE RECONNECTED TO A NEW CIRCUIT LEAVE ALL HORIZONTAL WIREMOLD AND ADDITIONAL EXISTING WIRING FOR RECONNECTION TO NEW CIRCUIT. SEE BE2.O1 FLOOR PLAN FOR ADDITIONAL INFORMATION. 'pl ELECTRICAL 111 'LAN NOTES 0 DISCONNECT AND REMOVE ALL WIRING AND FLOOR PEDESTALS FROM LIGHTED BOOK SHELVES TO BE DEMOLISHED. REMOVE EXISTING WIRING COMPLETELY OUT OF FLOOR DUCT AND SERVING PANEL. (TYPICAL). • REMOVE EXISTING FLOOR RECEPTACLE, COVER PLATE AND WIRING COMPLETELY OUT OF FLOOR DUCT AND SERVING PANEL. O REMOVE EXISTING RECEPTACLE POWER PEDESTAL AND WIRING COMPLETELY OUT OF FLOOR DUCT AND SERVING PANEL. O EXISTING FLOOR DUCT SYSTEM WITH POWER & DATA REMOVE ALL POWER CIRCUITS A/9,11,13,15,17,19 & 21 COMPLETELY OUT OF FLOOR DUCT SYSTEM AND SERVING PANEL 'A'. VERIFY CIRCUITS PRIOR TO DEMOLITION. 0 REMOVE ALL DATA PEDESTAL AND WIRING OUT OF FLOOR DUCT SYSTEM BACK TO SERVING PATCH PANEL 0 REMOVE EXISTING RECEPTACLE, CONDUIT AND WIRING BACK TO NEXT ACTIVE DEVICE OR JUNCTION BOX. MAINTAIN CONNECTION TO OTHER EXISTING CIRCUITS THAT MAY SHARE CONDUIT. 0 REMOVE EXISTING RECEPTACLE, CONDUIT AND WIRING BACK TO NEXT ACTIVE DEVICE OR JUNCTION. BOX. MAINTAIN CIRCUIT CONTINUITY TO OTHER DEVICES ON THIS CIRCUIT. 0 REMOVE EXISTING TELECOM OUTLET, BACKBOX, CONDUIT AND CABLING BACK TO SERVING PATCH PANEL. A/6 A/42 BREAK R 110 A /42 GENERAL NOTES 1. EXISTING DASHED RECEPTACLES, GEAR AND OTHER ITEMS ARE SHOWN FOR REFERENCE AND ARE TO REMAIN UNLESS OTHERWISE NOTED. NOT ALL EXISTING DEVICES ARE SHOWN. 2. EXISTING DASHED LIGHT FIXTURES AND SWITCHES ARE SHOWN FOR REFERENCE AND ARE TO REMAIN UNLESS OTHERWISE NOTED. NOT ALL EXISTING LIGHT FIXTURES ARE SHOWN. 3. EXISTING CIRCUITS INDICATED ARE FROM AS—BUILT DRAWINGS. CONTRACTOR TO VERIFY ALL APPLICABLE CIRCUITS PRIOR TO WORK. LOAT L JA/ L A/4 STUDY; (7 r-1 I I I I I I L_J 4.-'1 I I L_J A/4 --7 A/1 r A/4 LJ A/6 A/6 F-1 A/6 I I 1 I 1 I L_J r-1 _; A/42 A 6 WORK ROOM r-1 1 1 L_J 109 :.'r-1 G \I I I I I I L_J 0 A/4 MAIN DES< 0 A/4 r I I I L_J A/ A/6 OFFICE A/6 108 A/6 CUSTODIAN 107 A/6 A /4 (A/2 A/2 A/2 `A/2 A /2 0A/2 A/2 A/42 u A/1 A/1 A/1 J A/3 [ i. -_I A/42 J A TACKS/READING 105 A r -i L_J A 1 A/3 A/ r-1 A/42 J A /3 A/1 ENTRY LOBBY A/42 100 _J J A/3 A A /42 MEN'S TOILET 101 STORAGE 104 WOMEN'S TOILET 102 A NTNG ROOM 1 AI/42 1J I I I I I I L_J L_J DEMOLITION REF SCALE: 1/8" =1'-0" ECTED CEILING PLAN -ELECTRICAL REVIEWED FOR COMPLIANCE WITH N70 -NEC FEB 01 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2018 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com z w 0 REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title DEMOLITION PLANS ELECTRICAL Drawing Number 01 RFn1 ni fl MflPi AMC flW( N ti TtH?t1tA R(II.UIIA ARCHITFCTA INCA B/6- wP ELEC. EXIST CT CABINET -EXIST PNL 'A' rEXISL PNL 'B' B/25 F-7± B/ , 6 , 1'4 KIT 110 B /2 EXISTING WIREMOLD 4000 5 B/18 B/3 A/21 MAINT/STOR. BREAK RM 3 112 (11 -PB/ A 36 A/38 ORK ROO 109 A 37 A 39 1— fit A/32 '14'A/32 OFFI 11 J 3 tn, 01;„ tiv_21 115 L OFFIC 116 334b -35 OFFI Li 5 f\ 3 OPEN OFFICE A/14 EIVING A/18 4.0 35 Ktti A/14 108 A/36 r-Lsx A/34 14 " A/32 CUSTODIA 107 HALLWAY 105 A/26 A iB fit A/28 %NOR' A/34 B/29 29 39 37 7 37 TRAINING 118 STORAGE 119 39 ir 'I4 44) A/28___A._A/29 ENTRY LOBBY 100 A/29 lit 39 CONFERENCE 120 39 A /25 Ulf 11 A/29 MEN I0 STORAGE 104 1.11I WOMEN A/20 102 44) A/25 TRAINING ROOM 103 A/23 .11, A/25 ij A/25 WP FLOOR PLAN - POWER SCALE : 118" = Ft -AN NOTES cam) 0 PROVIDE NEW SWITCHES AND CONNECT TO THE SIX EXISTING FIXTURES IN THIS ROOM AS INDICATED. PROVIDE ALL CONDUIT AND WIRING AND CONNECTIONS. @ RECEPTACLES IN ROOMS 114 THRU 118 SHALL BE CONTROLLED RECEPTACLES. SEE CONTROL DIAGRAMS ON SHEET 8E8.02. PROVIDE ALL POWER PACKS, OCCUPANCY SENSORS AND LABELING OF RECEPTACLES AS INDICATED. © RECEPTACLES SHALL BE MOUNTED ON NEW 4—FOOT WALL. LOCATE AT STANDARD HEIGHTS. TYPICAL. 0 PROVIDE NEW SURFACE MOUNT FIXTURE TYPE 'S1' AND CIRCUIT TO EXISTING CIRCUIT A/6 AND SWITCH AS SHOWN. 0 PROVIDE A 10"xl 0" RECESSED ACCESS PANEL IN NEW COLUMN ROUTED FROM TOP OF SHORT WALL TO THE ACCESSIBLE CEILING SPACE ACCESS PANEL TO BE USED FOR TELECOM CONDUIT TRANSITION POINTS. ROUTE ALL CONDUITS UP COLUMN TO THE ACCESSIBLE CEILING SPACE AND TO POWER PANEL OR TELECOM RACK AS REQUIRED. CI PROVIDE NEW SURFACE MOUNTED WIREMOLD JUNCTION/ OUTLETS BOX AT WEST END OF EXISTING HORIZONTAL WIREMOLD, AND PROVIDE NEW CONDUIT AND WIRING HOME RUN TO NEW CIRCUIT A/21. ROUTE NEW CONDUIT AND WIRING CONCEALED IN NEW WALL AND ABOVE CEILING. CHANGE LABEL ON EXISTING OUTLETS TO READ A/21. 0 PROVIDE OCCUPANCY SENSORS FOR SWITCHING RECEPTACLES AT OPEN OFFICE AREA. PROVIDE ALL POWER RACKS AND CONNECTIONS AS REQUIRED. @ EXISTING LIGHT SWITCHES TO REMAIN FOR CONTROL OF EXISTING LIGHT FIXTURES IN OPEN OFFICE, RECEIVING AND HALLWAY AREA'S. FLAN NOTES 0 PROVIDE NEW LAY—IN LIGHT FIXTURE TYPE 'R1' AND CIRCUIT AS INDICATED. TYPICAL ROOMS 118 AND 119. 0 PROVIDE NEW PENDANT LIGHT FIXTURE TYPE 'P1' IN ROOMS 115 THRU 117 AND CIRCUIT AS INDICATED. HANG PENDANTS FROM EXISTING T—BAR & STRUCTURAL CEILING DOWN TO 9—FEET AFF. PROVIDE LOW VOLTAGE SWITCH WITH DIMMING CONTROL IN ROOMS 115 THRU 118. PROVIDE POWER PACKS AS REQUIRED. SWITCHES SHALL BE MANUAL ON AUTO OFF. SEE OFFICE LTG/RECEPT CONTROL DIAGRAM ON 0E8.02. 0 PROVIDE LOW VOLTAGE VACANCY SENSOR SWITCH IN THIS ROOM. PROVIDE POWER PACK AS REQUIRED. SWITCH SHALL BE MANUAL ON AUTO OFF. 0 PROVIDE NEW LAY—IN FIXTURE TYPE 'R1' AND CIRCUIT TO EXISTING CIRCUIT A/6 AND SWITCH AS SHOWN. 0 PROVIDE LOW VOLTAGE SWITCH AT TWO LOCATIONS IN THIS ROOM. PROVIDE POWER PACK AND CONNECT TO NEW CEILING MOUNT OCCUPANCY SENSOR. SWITCH SHALL BE AUTO ON AUTO OFF. 0 CIRCUIT EXISTING FIXTURES TO A/4 AND SWITCH AS INDICATED. O RELOCATE EXISTING EXIT/EGRESS LIGHT TO THIS LOCATION. CONNECT TO EXISTING CIRCUIT A/42. O REMOVE EXISTING FIXTURE FROM CIRCUIT A/1 AND CONNECT TO EXISTING CIRCUIT A/3 AND CONNECT TO NEW SWITCHES AS INDICATED. O EXISTING FIXTURES TO REMAIN ON CIRCUIT A/3 BUT SHALL BE RECONNECTED TO NEW SWITCHES AS INDICATED. OFFICE GENERAL NOTES 1. ALL RECEPTACLES & LIGHT FIXTURES SHOWN IN SOLID LINE WEIGHT ARE TO BE PROVIDED NEW AND CIRCUITED AS INDICATED. TYPICAL 2. ALL RECEPTACLES AND LIGHT FIXTURES SHOWN WITH DASHED LINES ARE EXISTING TO REMAIN, UNLESS OTHERWISE NOTED. 3. EXISTING CIRCUITS INFORMATION HAS BEEN PROVIDED FROM EXISTING DRAWINGS, E.C. TO VERIFY EXISTING CIRCUITS PRIOR TO WORK. OFFICE OFFICE 116 117 ELEC. 111 EAK RM OPEN OFFIC 114 t 4 KIT 110 L_ r L _ ECEIVING HALLWAY TRAINING 118 OFFICE 108 CONFER 3USTOD A ENTRY LOBBY 100 I a, L _ J A STORAG r1 - I 1 1 L J [1 L J r - - I 1 I 1 I 1 L _ J [TRAINING R00,1 L _ J WOMEN REVIEWED FOI-i COMPLIANCE WITh NFPA 70 - NEC FEB 0 1 2018 City of Tukwila— BUILDING DIVIS 0 /m FLOOR PLAN - LIGHTING SCALE : 1/8" = 1'-0" RECEIVED CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472,3300 www.treswest.com 1— REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title FLOOR PLAN POWER/LIGHTING Drawing Number CIIPYRIGH 2015 pialL1111/14 AllICHITFCT RP9 ni I nr1P PI 1M DWP 1 TO. 111A/C4 ELEC. EXIST PNL A �EXI� PNL B KIT 110 GENERAL NOTES 1. CONTRACTOR TO PROVIDE ALL CONDUIT SLEEVES SIZED AS REQUIRED FOR ROUTING OF TELECOMMUNICATIONS CABLING THROUGH WALLS AND NON ACCESSIBLE CEILING AREAS. IN ADDITION PROVIDE (2) 4 -INCH CONDUITS FROM MDF TELECOM RACK TO THE ACCESSIBLE CEILING SPACE FOR TELECOM CABLE ROUTING. I I BREAK RM 112 WORK ROO 109 OFFI rTP ON ROOF ABOVE 108 CUSTODIAN 107 e\D'1,) OPEN OFFICE 0 GE L_u 7 1----J ---J r --T Lrf RI) L__ HALLWAY 105 I,I —__'— 1T L - AL _ TRAINING 118 STORAGE 119 ENTRY LOBBY 100 CONFERENCE 120 MEN 0 WOMEN 102 STORAGE 104 TRAINING ROOM 103 FLOOR PLAN -MECHANICAL SCALE : 118" = 1'-0" F'LAIN NOTES =Km 70 PROVIDE A ONE INCH CONDUIT FROM EACH TELECOM OUTLET TO THE ACCESS PANEL LOCATION AS SHOWN PER NOTE 8. TRANSITION CABLE ROUTING FROM ONE INCH CONDUITS TO THREE IN CONDUITS TO ACCESSIBLE CEILING SPACE. TYPICAL ALL OUTLETS ON THIS WALL. PROVIDE (2) THREE INCH CONDUIT FROM ACCESS PANEL $L LOCATION UP TO THE ACCESSIBLE CEILING SPACE. TRANSITION ALL TELECOM CABLING FROM ONE INCH CONDUITS THROUGH THREE INCH CONDUITS TO THE ACCESSIBLE CEILING SPACE. 0 EXISTING FIBER OPTIC LIU/PATCH PANEL WITH SERVICE ENTRANCE FIBER OPTIC CABLES. C.) PROVIDE (1) NEW 12 STRAND FIBER OPTIC WALL MOUNTED LIU/PATCH PANEL ADJACENT EXISTING LIU, AND TERMINATE NEW 12 STRAND FIBER OPTIC CABLE ROUTED FROM MDF ROOM 109A FIBER PATCH PANEL IN RACK. WALL MOUNT PATCH CABINET SHALL BE ORTRONICS OR-615SMFC-12P. 11 PROVIDE WEATHER PROOF IN -USE RECEPTACLE AND OUTLET BOX ON ROOF ADJACENT TO NEW CU -01. ELEC. 111 -EXIST PNL A -EXIEPNL B FLAN NOTES 0 PROVIDE NEW TELECOM OUTLET IN NEW WALL AS INDICATED. ROUTE CABLING ABOVE CEILINGTO NEW TELECOM RACK IN MDF ROOM 109A. REMOVE EXISTING TELECOM, FACEPLATES, JACKS AND CABLING, AND PROVIDE NEW CAT 6 JACKS FACEPLATES AND CABLING. ROUTE TO NEW TELECOM RACK IN MDF ROOM 109A. O PROVIDE NEW MDF FREE STANDING RACK, PATCH PANELS, WIRE MANAGERS, LADDER RACK AND ADDITIONAL EQUIPMENT AS INDICATED ON SHEET BE8.02. EXISTING WALL MOUNTED TELECOM PATCH PANELS. REMOVE EXISTING TELECOM CABLING AND PATCH PANELS FROM THIS ROOM. 0 NEW CU -01 SHALL BE LOCATED ON ROOF ABOVE MDF ROOM 109A. CIRCUIT CU -01 TO PANEL 'A' AS INDICATED ON MECH. EQUIPMENT AND PANEL SCHEDULES. PROVIDE NEMA 3R DISCONNECT SWITCH AND FUSES ADJACENT UNIT WITH LIQUID TIGHT FLEX CONDUIT FROM DISCONNECT TO UNIT. SIZE FUSES PER MANUFACTURES REQUIREMENTS. 0 AC -01 LOCATED IN MDF ROOM 109A SERVED BY CU -01. PROVIDE CONDUIT, WIRING AND ALL CONNECTIONS BETWEEN AC -01 & CU -01 FOR COMPLETE OPERATION. PROVIDE FUSED DISCONNECT SWITCH AND FUSES AS REQUIRED. SIZE PER MANUFACTURES REQUIREMENTS. OFFICE 1 MAINT/STOR. II OFFIC�.i- 116 L a � I OFFIC' KIT BREAK RM W • RK R00 EIVING STORAGE TRAINING HALLWAY CUSTODIAN CONFERENCE ENTRY LOBBY STORAGE. TRAINING ROOM 103 WOMEN L' FLOOR PLAN -SYSTEMS SCALE : 1/8" =1'-0" ; 'm REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC FEB 0 1 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2018 PERMIT CENTER rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 IMMININNA TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com U) ii Dw O I— Nt I-- I-- 0 N REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title FLOOR PLAN SYSTEMS AND MECHANICAL Drawing Number RP1 ni PI (VIP DI AM QV ZTJ hA fl AIr 2 0 CNI 0 RI HT 0!) 7(11nevi_ •A ARCM ITE TRIM r i WP ELEC. r 111 EXIST PNL A 1EXIPNL B EXISTING F.A. PANEL LOCATION KIT 110 :J�� MAINT/STOR 113 112 CSN O 'FIOE1 114 OFFICE 108 0 CUS •DIA OF -F1 1 1 r'Ti rF'-1 UJ1 UJB 1 1 L_-- i- —IAL I —14 L _J r T 1 LLL HALLWAY 105 ( nTh1 J EXISTING F A. ANNUNCIATOR LOCATION I\ 1 LJJ -2- 1 - 1'C L - L i--11.1 C ENTRY LOBBY " X100 F TRAINING 118 STORAGE 119 CONFERENCE 120 MEN 101 WOMEN 102 TRAINING ROOM 103 FLOOR PLAN - FIRE ALARM SCALE : 1/8" = 1'-0" 0 'LAN NOTES O REPLACE EXISTINGDUCT DETECTOR IN SAME LOCATION ABOVE DROP CEILING. PROVIDE REMOTE TEST STATION ON CEILING BELOW DEVICE. 20 REPLACE EXISTING DEVICE IN SAME LOCATION ABOVE DROP CEILING WITH NEW. UTILIZE EXISTING CONDUIT AND WIRING. PROVIDE ALL CONNECTIONS. O DEMO EXISTING FA DEVICE. TIE WIRES TOGETHER. PROVIDE COVER PLATE. O REPLACE EXISTING FA PANEL & REMOTE ANNUNCIATOR WITH NEW EST IO1000 REFER TO SPEC. AND ONE -LINE DIAGRAM. O PROVIDE NEW DEVICE AND CONNECT TO FIRE ALARM PANEL. PROVIDE ALL NEW CONDUIT AND WIRING AS REQUIRED. O REPLACE EXISTING DEVICE IN SAME LOCATION WITH NEW. UTILIZE EXISTING CONDUIT AND WIRING. PROVIDE ALL CONNECTIONS. O FLOOR PLAN CEILING LEVEL - FIRE ALARM SCALE 1/8" =1'-0" REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 01 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 112010 PERMIT CENTER architects rolluda architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 limet TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com REVISION DATE Design: Drawn: Checked: Project No. FLR BCY, BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title FLOOR PLAN FIRE ALARM Drawing Number RFq (1/ FI (VIP PI AAI FIRE Al APIA fWr YR16HT(8121118 ROI_L11RA ARCHITECTS INCA EXIST PANEL A LOCATION: SERVING: FED FROM: ELECTRICAL 114 LOAD 208/120 VOLT 400.AMP BUS RATING SCCR: 22,000 A 3 PHASE 400 AMP MAIN BREAKER AFC: 4 WIRE MOUNTING: SURFACE coNDurrAnfiRE SIZE PANEL A #ANUAL MTF STARTER CKT LOAD DESCRIPTION TYPE KVA NP PHASE MP KVA TYPE LOAD DESCRIPTION CKT 1 LIGHTING L 0.819 20/1 A 314"C, 3 #10 & (1) #10 GND BY E.C. 20/1 1.470 L LIGHTING 2 3 LIGHTING L 0.728 20/1 - B - 20/1 0.609 L LIGHTING 4 5 LIGHTING L D624 ' 20/1 w C 20/1 1.246 L LITGHTING, EF -2 6 7 LIGHTING L 1228 2011 A 20/1 1.008 L LIGHTING 8 9 LIGHTING ROOMS 115-119 L 0.432 20/1 3.000 - 9 WH -1 20/1 1.008 L SOFFIT LIGHTING 10 11 CU -01 & AC -01 M - 1.260 - 30/2 - 50/3 - - A C 20/1 1.008 L SOFFIT LIGHTING 12 13 A 13 20/1 1.200 R RECEPTACLES ROOM 102 14 15 SPARE S - 20/1 18 B AC -3 20/1 0.600 R RECEPTACLES ROOM 102 16 17 SPARE S - 20/1 20 21 C 20/1 0.360 R RECEPTACLES 18 19 SPARE S - 2011 A 20/1 0.390 20/1 0.540 R RECEPTACLES 20 21 RECEPTACLES R 0.540 20/1 B 1.192 30/1 2.400 ID DRY BLOWER CIRCULATION PUMP 23 RECEPTACLES R 0.360 20/1 20/1 C 20/1 0.180 R FLOOR RECEPTACLES 24 25 RECEPTACLES R 0.360 20/1 A 20/1 0.500 20/1 0.500 A COPIER 26 27 DRY BLOWER D 2.400 30/1 B - 20/1 0.700 A FAX RECEPTACLE 28 29 RECEPTACLES R 0.540 20/1 20/1 C 20/1 0.400 D AUTOMATIC DOOR MOTO 30 31 EXTERIOR SIGN L 0.750 20/1 A 2011 0.720 20/1 0.540 R RECEPTACLES 32 33 RECEPTACLE MDF RM 109A D 1.000 20/1 B 0.720 20/1 0.360 R RECEPTACLES 34 35 RECEPTACLES R 0.350 20/1 2011 C 20/1 0.500 R RECEPTACLES 36 37 RECEPTACLES R 0.500 20/1 A 2011 0.720 20/1 0.500 R RECEPTACLES 38 39 RECEPTACLES R 0.500 20/1 9 20/1 1.000 D MDF 109A 40 41 WATER COOLER 0 0.430 20/1 LOAD TYPE C 20/1 0.000 L EMERGENCY LIGHTING 42 D A K LM TOTAL LOADS CONN. LOAD 1.58 12.74 32.39 0.75 7.60 PHASE LOAD PHASE A= 10.05 KVA PHASE 13= 12.28 KVA PHASE C= 6.84 KVA CALC. LOAD 1.98 11.37 LOAD TYPE L R M H WI -I D A K LM TOTAL LOADS CONN. LOAD 10.93 7.94 1.26 7.63 1,20 1,26 28.96 KVA 80.39 AMP CALC. LOAD 13.66 7.94 1,26 7.63 1.20 0.32 32.01 KVA 88.84 AMP NOTES: BOLD TEXT INDICATES REVISIONS OR NEW LOADS TO THIS EXISTING PANEL. ALL OTHER CIRCUITS E EXISTING TO REMAIN, PROVIDE NEW CIRCUIT BREAKER WHERE BREAKER IS IN BOLD TEXT. EXIST PANEL B LOCATION: SERVING: FED FROM: ELECTRICAL 114 LOAD 208/120 VOLT 400 AMP BUS RATING SCCR: 22,000 A 3 PHASE AFC: 4 WIRE MOUNTING: SURFACE coNDurrAnfiRE SIZE PANEL A #ANUAL MTF STARTER CKT LOAD DESCRIPTION TYPE KVA MP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 RECEPTACLES R 0.360 20/1 A 314"C, 3 #10 & (1) #10 GND BY E.C. 20/1 0.360 R RECEPTACLES 2 3 RECEPTACLES 105,112,113, ROOF R 1.260 20/1 - e - 20/1 0.360 R RECEPTACLES 4 5 RECEPTACLES R 0.500 20/1 w C 20/1 0.180 R RECEPTACLES 6 7 AC -1 M - - 11.340 - - 50/3 - - A 20/1 0.200 0 FIRE ALARM PANEL 8 9 13 20/2 - 3.000 - WH - WH -1 10 11 C 12 13 AC -2 M - - 13.068 - 50/3 - - A 30/2 - 4.600 - WH - WH -2 14 15 13 16 17 C 20/1 0.750 H HOT WATER DISPENSER 18 19 AC -3 M - - 7.164 - - 30/3 - - A 20/1 0.360 R RECEPTACLES ROOF TOP 20 21 B 20/1 0.667 M EF -1 22 23 C 20/1 0.390 L SITE LIGHTING 24 25 SPRINKLER CONTROLLER D 0,180 20/1 A 20/1 1.192 L SITE LIGHTING 26 27 CIRCULATION PUMP M 0.150 20/1 B 20/1 0.500 D HVAC CONTROL 28 29 RECEPT COPIER HALL 105 D 1.000 20/1 C 20/1 0.500 D RECEPT DED. STAFF WORK AREA 30 31 RECEPT OFFICE 117, HALL 105 R 1.080 20/1 A 20/1 - S SPARE 32 33 RECEPT OFFICE 116 R 0.900 20/1 B 20/1 1.080 R RECEPT OPEN OFFICES 114 34 35 RECEPT OFFICE 115 R 0.90 20/1 0 2011 0.720 R RECEPT OPEN OFFICES 114 36 37 RECEPT TRAJNING RM 118 R 1.080 2011 A 2011 0.720 R RECEPT OPEN OFFICES 114 38 39 RECEPT HALL 105, RMS 119, 120 R 1.080 20/1 B 2011 1.080 R RECEPT OPEN OFFICES 114 40 41 RECEPT OPEN OFFICE 105 0 0.360 2011 C 2011 0.720 R RECEPT OPEN OFFICES 114 42 PHASE LOAD PHASE A= 18.36 KVA PHASE B= 21,40 KVA PHASE C= 18.04 KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 1.58 12.74 32.39 0.75 7.60 2.74 13.07 57.80 KVA 160A4 AMP CALC. LOAD 1.98 11.37 32.39 0.75 7.60 2.74 3,27 60.09 KVA 186.80 AMP NOTES: BOLD TEXT INDICATES REVISIONS OR NEW LOADS TO THIS EXISTING PANEL. ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. PROVIDE NEW CIRCUIT BREAKER WHERE BREAKER IS IN BOLD TEXT. MECHANICAL EQUIPMENT SCHEDULE MISC EQUIP. VOLT/ PHASE LOAD CIRCUIT coNDurrAnfiRE SIZE FUSED DISC. #ANUAL MTF STARTER MAGNETIC oITR STATE, PLOT SW AFC IN AMPS AT PANEL REMARKS AMP KVA/W HP BKR PANEL Split -System Air -Conditioner Schedule 20 8 / 1 - - - - - 314"C, 3 #10 & (1) #10 GND BY E.C. POWER CONNECTION SERVED FROM CU -01 la ur 208 i 1 - 1.2 0 - 30/2 A 3/4"C, 3 #10 (1) #10 GND& BY E.C. CONDENSING UNF A& w 120/208V SERVICE METER BASE AND SOCKET LOCATED ON EXTERIOR WALL PROPERTY / LINE 1.1" 30"x36"x11" METERING EQUIPMENT ENCLOSURE WITH HINGED DOOR Ld 1"C. WITH CONDUCTORS AS REQUIRED 30"x36"x11" UTILITY PULLBOX WITH HINGED DOOR STREET CROSSING ALL WORK AND MATERIAL PROVIDED BY UTILITY 4 #500 MCM, 1 #2 GND. IN 3-1/2"C 1 FILII 1 1 1400A, 3P1 PNL 1 I F'NL A B I I L I I LI_ 3/0 Cu. 1 GROUND 1 UTILITY CONNECTION POINT 4" GRS 90" ELL 4" SCHEDULE 80 PVC UNDERGROUND SERVICE CONDUIT FROM PROPERTY LINE. -3- 3/0 Cu. GROUND REFER - TO SECTION 1645 FOLUER ONE -L INE DIAGRAM SCALE: NONE NOTE: POWER ONE -LINE DIAGRAM IS SHOWN FOR REFERENCE ONLY. ALL SERVICE AND DISTRIBUTION GEAR IS EXISTING TO REMAIN. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 01 2018 ty of Tukwila BUILDING DIVISION rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 7 TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com CJ Li REVISION DATE Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 RECEIVED CITY OF TUKWILA JAN 11 2018 PERMIT CENTER Drawing Title POWER ONE -LINE DIAGRAM AND PANEL SCHEDULES Drawing Number BE5.01 PPR (11 PCIWPP rIMP 1 IMP rilACIPAKA n 2 0 0 eNi 0 CN1 VRI 4521115 ROI LUN* ARCHITECTS INC‘-' (E)EMCS CONTROL RECONNECT EXISTING TWO el (2) TELEPHONE LINES CONTROL RELAY {----------�j--{D}-- (E)DOOR HOLDER CIRCUIT PROVIDE AND CONNECT CONTROL I`^ -4 TO 12OVAC POWER RELAY - �R�----�----(%__--w� (E)FIRE/SMOKE DAMPER CIRCUIT RETURN (E)FIRE ALARM AUDIO/VISUAL ALARM CIRCUIT TYPICAL EXISTING FIRE ALARM SLC LOOP ..____OF DEVICES AND DETECTORS PROVIDE REMOTE INDICATING LIGHT TO SIGNAL SMOKE DUCT DETECTOR ACTIVATION. MOUNT IN CEILING BELOW UNIT. PROVIDE CONNECTION TO DUCT SMOKE DETECTORS FOR ALL MECHANICAL UNITS OF 2000 CFM AND OVER SEE MECH DRAWING EQUIP. SCHEDULES. � (E)HVAC DDC CONTROL PANEL HVAC i FOR HVAC SHUT DOWN L _! NEW FIRE ALARM SLC LOOP DEVICES AND DETECTORS -2i---AIS (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL -E-------F (E)AUDIO/VISUAL ALARM CIRCUIT TYPICAL I 1 I > 1/1 DEDICATED 120V CIRCUITS, SEPARATE HOME RUN AND INSULATED GROUND. NEW HONEYWELL FIRE—LITE F.A. PANEL NEW FA—NAC PANEL 7C A © AUDIO/VISUAL ALARM CIRCUIT TYPICAL MAP FIRE ALARM GRAPHIC MAP -I FAA I FIRE ALARM REMOTE LCD ANNUNCIATOR BATTERY CABINET GROUNDING FIRE ALARM SYSTEM ONE -LINE DIAGRAM SCALE: NONE REMOVE EXISTING FIRE ALARM DIALER. FIRE ALARM NOTES; 1.. PROVIDE ALL J -BOXES, CONDUIT, WIRING & CONNECTIONS TO ALL DEVICES FOR COMPLETE FIRE ALARM SYSTEM. 2. ALL DEVICES WILL BE MOUNTED IN AN ACCESSIBLE SPACE AND AT THE ELEVATION PER NFPA 72, ADA, AND AHJ CODES. 3. PROVIDE FLUSH MOUNT BACK BOXES FOR ALL DEVICES IN ALL FINISHED SPACE. 4. PROVIDE COMPLETE GROUNDING TO EQUIPMENT PER MANUFACTURERS RECOMMENDATION. 5. SEE FIRE ALARM SPECIFICATION FOR COMPLETE DETAILS. 6. PROVIDE NEW FIRE ALARM PANEL ADDRESSABLE. 7. PROVIDE SHUT DOWN CONNECTIONS FOR ALL 2000CFM HVAC UNITS WITH DUCT DETECTORS AS SHOWN. 8. SET ALL VISUAL DEVICES TO PROVIDE THE RIGHT COVERAGE OF CANDELA FOR THE SPACE PER NFPA 72 AND AHJ CODES. 9. SET ALL AUDIO DEVICES TO TEMPORAL AND TO BE 15dB ABOVE AMBIENT SOUND LEVEL OF THE ROOM PER NFPA 72 CODES TABLE. 10. ALL AUDIO AND VISUAL DEVICE WILL BE SYNC PER NEPA 72 CODES. 11. PROVIDE COMPLETE REPROGRAMMING OF SYSTEM TO UPDATE ALL ZONES, ADDRESSES, AND DIALER MONITORING BY POINTS. 12. PROVIDE COMPLETE SHOP PLANS FOR INSTALLATION AND AS -BUILT SET OF THESE PLANS NEXT TO FIRE ALARM PANEL ON COMPLETION. 13. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. 14. PROVIDE FIRE ALARM DIALER FOR MONITORING. 15. REPLACE EXISTING FIRE ALARM SYSTEM WITH NEW HONEYWELL FIRE -LITE FIRE ALARM PANEL AND ALL FIELD DEVICES. UTILIZE EXISTING CONDUIT AND WIRING EXISTING FIRE ALARM DEVICE LOCATIONS SHOWN ON FIRE ALARM FLOOR PLANS. ALL NEW .FIRE ALARM DEVICES PROVIDE CONDUIT, CABLING, AND CONNECTIONS FOR A COMPLETE OPERATIONAL SYSTEM. 16. FIRE ALARM CONTRACTOR TO SUBMIT DRAWINGS FOR FIRE ALARM PERMIT BY TUKWILA BUILDING DEPARTMENT. 17. PROVIDE THE AHJ AT FINAL ACCEPTANCE THE FOLLOWING DOCUMENTS; a. AS -BUILT DRAWINGS SHALL BE FULL CONSTRUCTION SET WITH REDLINE MARKUPS THAT CONTAIN THE FOLLOWING (ALL ZONING, DEVICE POINT NUMBERS, NEW DEVICE CONDUIT OR WIRING PATHWAYS, AND EXACT LOCATION OF DEVICES AND PANELS.) b. EXISTING AS -BUILT DRAWINGS SHALL HAVE ALL FIRE ALARM PANELS AND DEVICES. c. HAFT SIZE GRAPHIC MAP OF EACH FLOOR WITH ZONES AND ADDRESSABLE POINT DEVICES. ( NO WIRE ) d. CENTRAL STATION MONITORING PRE-TEST REPORT OF ALL ADDRESSABLE POINTS. e. FIRE ALARM PANEL ALARM, SUPERVISORY, AND TROUBLE EVENT LOG REPORT OF ALL DEVICES. f. ADDRESSABLE POINTS LIST. g. WRITTEN DETAIL DESCRIPTION OF EACH DUCT DETECTOR LOCATION TO DIRECT A PERSON TO THAT LOCATION IN THE CLOSEOUT DOCUMENTS. PROVIDE PHENOLIC LABEL INDICATING FOR ALL DUCT DETECTORS. h. COMPLETED NFPA 72 RECORD OF COMPLETION AND INSPECTION CURRENT FORMS TO OWNER AND AHJ. 1. PROVIDE THE DIGITAL COPY OF ALL ABOVE ON ONE FOLLOWING (CD-ROM, DVD, OR FINGER DRIVE). J. PROVIDE ALL THE ABOVE DOCUMENTS IN O&M MANUALS BINDER. k. PROVIDE CD-ROM, DVD, OR FINGER DRIVE OF PROGRAM DATA IN FIRE ALARM PANEL AS REQUIRED BY NFPA-72 CODES. REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC FEB 01 2018 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 GINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest.com XUCe° D D W rrW� z v) I� < I— o co JFR 0 M Cn Cl/ i72 so c.o 1- W 1— 1 - REVISION DATE Design: Drawn: Checked: Project No. BCY, FLR BCY, BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 City of Tukwila BUILDING DIVISIOjI RECEIVED CITY OF TUKWILA JAN 11 2010 PERMIT CENTER Drawing Title FIRE ALARM ONE -LINE DIAGRAM Drawing Number rzJst ni F11= Al ARRA [ANF 1 IMP n[AnPARA nw( 2 0 0 M ('1 N OMB RRl.t.URA ARCHITECTS INC - STRUCTURAL CEILING SUSPENDED CEILING rFININSHED FLOOR TELECOM CONDUIT DETAIL SCALE: NONE (T WALL TELECOM OUTLET DEVICES AND COVERPLATE. ALL WALL OUTLETS SHALL BE MOUNTED AT SAME HEIGHT AS ADJACENT POWER OUTLETS UNLESS OTHERWISE NOTE. 20 STUB OUT 1" CONDUIT TO ACCESSIBLE CEILING SPACE. PROVIDE PLASTIC BUSHINGS FOR ALL CONDUIT ENDS. 120VAC POWER 55 NPP2OPLBP CONTROL RECEPTACLE PLUG LOAD CIRCUIT # SWITCHED RECEPTACLES S a S' 9 (0 SPLIT CONTROLLED RECEPTACLE DETAIL SCALE: NONE TO NEXT SWITCHED RECEPTACLE TO NEXT NON -SWITCH RECEPTACLE NOTE: 1. PROVIDE ALL DEVICES, J—BOXES, CONDUIT, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. 2. REFER TO ELECTRICAL POWER & LIGHTING PLAN SHEETS FOR DEVICE QUANTITY. 3. PROVIDE SPLIT CONTROLLED RECEPTACLE WITH CONTROL SYMBOL AND "CONTROLLED" ABOVE OR SIDE OF THE CONTROLLED OUTLET. PART NUMBER LEVITON 5262—S1G OR EQUAL. 4. OCCUPANCY SENSOR WILL CONTROL THE SWITCHED RECEPTACLE. DUAL RJ -45 JACK INSERT FOR UTP JACK IDENTIFICATION , JACK IDENTIFICATION LABEL 16 POINT TYPE LETTERING BLACK ON WHITE DUAL RJ -45 JACK INSERT FOR UTP DUAL RJ -45 JACK INSERT FOR UTP SINGLE GANG FACEPLATE NOTES: 1. PROVIDE DOUBLE GANG COVERPLATES IN AREAS REQUIRING MORE DROPS THEN WILL FIT INTO A SINGLE GANG PLATE. 2. PROVIDE 5 SQUARE BACK BOXES AT ALL TELECOM OUTLET LOCATIONS. 3. DETAILS ARE SHOWN AS A GUIDELINE AND ARE NOT A REPRESENTATION OF EVERY SITUATION. 4, SEE SPECIFICATION SECTION 27 10 00 FOR MORE REQUIREMENTS. 5. SEE FLOOR PLANS WHERE SUB—NUMBER IN SYMBOL INDICATES QUANTITIES OF DROPS PER OUTLET. TYPICAL TELECOM WALL OUTLET DETAILS SCALE: NONE UTP CABLE SCHEDULE 000000 000000 000000 000000 000000 000000 DESCRIPTION REMARKS SPACE T v Q000na 1Da000 ocaaco aaaaa aaaaaa ac D DJ aaoaaa ...._ora: 12 STRAND MULTIMODE FIBER OPTIC CABLE 3 IE- afl caaapa aaoaaa aaaaoa 1• UTP CABLE ROUTED FROM OUTLETS IN CONDUITS TO ACCESSIBLE a oaaa aaa as anacaa (--' <-- 2. ALL TELECOMMUNICATION CABLES SHALL BE TERMINATED AT I ( OPEN n SPACE <////////////// UTP CABLE SCHEDULE TYPE DESCRIPTION REMARKS 11 FOUR PAIR UTP CATEGORY 6 CABLE FOR DATA, DATA, QUANTITY PER DEVICE AS NOTED ON FLOOR PLANS 1,2 12 STRAND MULTIMODE FIBER OPTIC CABLE 3 SCHEDULE NOTES:. 1• UTP CABLE ROUTED FROM OUTLETS IN CONDUITS TO ACCESSIBLE CEILING SPACE THEN THROUGH J—HOOKS TO TELECOM RACK. 2. ALL TELECOMMUNICATION CABLES SHALL BE TERMINATED AT A PATCH PANEL 3. ROUTE IN 1" INNERDUCT ABOVE CEILING BETWEEN MDF ROOM AND ELECT. ROOM 111. SUPPORT INNDERDUCT WITH J -HOOKS. DETAIL NOTES 0 SEE FLOOR PLANS FOR LOCATIONS OF TELECOMMUNICATION OUTLETS, PROVIDE QUANTITY OF CAT 6 DROPS PER OUTLET AS INDICATED INSIDE TELECOM SYMBOL ON FLOOR PLANS. ALL CABLING WILL PUNCH DOWN ON PATCH PANELS IN THE MDF. SEE THIS SHEET AND SPECIFICATION 27 10 00 FOR ADDITIONAL OUTLET REQUIREMENTS. O PROVIDE NEW FREE STANDING UPRIGHT FLOOR MOUNTED RACK. PROVIDE LADDER RACK FROM TOP OF FREESTANDING RACK TO BACK WALL, PROVIDE UTP WIRE MANAGEMENT PANELS AS SHOWN PER SPECIFICATION SECTION 27 10 00. O4 PROVIDE RACK MOUNTED CAT. 6 HIGH DENSITY PATCH PANEL PER SPECIFICATION SECTION 27 10 00 AND TERMINATE ALL UTP CABLES. O PROVIDE FIBER OPTIC PATCH PANEL CABINET AND CONNECTORS. TERMINATE AND TEST ALL FIBER OPTIC CABLES. SEE SPEC SECTION 27 10 00 FOR REQUIREMENTS. O ROUTE 12 -STRAND FIBER OPTIC CABLE FROM RACK MOUNT PATCH PANEL IN MDF TO WALL MOUNT PATCH PANEL IN ELECT. ROOM 111. TELECOM RACK MDF ROOM 109A SCALE: NONE NPODMDX WALL SWITCH SWITCHED RECEPTACLE CONTROLLER POWER PACK CEILING MOUNT DUAL ZONE PHOTO CELL NCMPDT9ARRJB BROWN BROWN CEILING MOUNT OCCUPANCY SENSOR 0 NPP16D 0 LIGHTING ROOM CONTROLLER DIMMING POWER PACK OFFICE L IC I-4TINC 'NG/RECEPTACLE CONTROL_ ID 1 AGRAM NTS NOTE PROVIDE ALL DEVICES, CONDUITS, WIRING AND CONNECTIONS FOR COMPLETE OPERATION. THIS DIAGRAM MAY NOT REPRESENT EACH ROOM/SPACE/AREA EXACTLY PROVIDE ALL DEVICES AS REQUIRED FOR EACH LOCATION. WHITE OOGE BUE VIOLET GRAY LIGHTING ROOM CONTROLLER DIMMING POWER PACK WIRE G CAT 6-E (CLASS 2) LIE VOLTAGE 0-10 VDC LOW VOLTAGE (1A 0 40 VDC/VAC) 15-24 VDC POWER ETHERNET LAN (CLASS 2) REVIEWED FOR COMPLIANCE - NEC FEB 01 2018 rolluda architects architecture planning interior design 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 TRES WEST ENGINEERS TRES WEST ENGINEERS, INC. 2702 SOUTH 42ND STREET, SUITE 301 TACOMA, WA 98409-7315 Phone: 253.472.3300 www.treswest,com w 0 0 0) Q > rn 0 S( ..i REVISION DATE City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 11 2018 PERMIT CENTER Design: Drawn: Checked: Project No. FLR BT FLR 331-16-01 Issuance BID SET Date: 11/6/2017 Drawing Title SYSTEMS ONE -LINE DIAGRAM Drawing Number 8 R•LL 11\Ii ♦NCH c Pt.P11 n9 CVCTPRAC tIMP 1 1M1= f11AC,PAI1