Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG18-0004 - LOOMIS - GAS PIPING TO 3 RTU'S (N) WOMENS RESTROOM
LOOMIS 15450 NELSON PL EXPIRED 01/15/19 PG 18-0004 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httD://www.TukwilaWA.ttov 2423049090 15450 NELSON PL Project Name: LOOMIS PLUMBING/GAS PIPING PERMIT Permit Number: PG18-0004 Issue Date: 3/27/2018 Permit Expires On: 9/23/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: INDUSTRIAL CRATING & PACKIN PO BOX 88299 , TUKWILA, WA, 98188 PAUL HARRINGTON 3421 S HENRY RD, GREENACRES, WA, 99016 ACE COMMUNICATION SERVICES INC PO BOX 1286 , ROSEBURG, OR, 97470 ACECOSI036KL /11 Phone: (509) 714-6301 Phone: (503) 807-1477 Expiration Date: 9/29/2019 DESCRIPTION OF WORK: GAS PIPING TO 3 RTU'S (N) WOMENS RESTROOM Valuation of Work: $80,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $805.41 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: wit it -ifpiti,i), Date: 1) I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not p sume to give authority to violate or cancel the provisions of any other state or local laws regulatin coy ru on or the performance of work. I am authorized to sign and obtain this development permi, and , _r a to t ; conditions attached to this permit. Signature: Print Name: Date: 3'`2'7 -)13 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing, All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction: 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: ***PUBLIC WORKS PERMIT CONDITIONS*** 16: Before permit can be issued applicant shall submit executed Non -Residential sewer Use Certification form listing all new plumbing fixtures. 17: Before permit can be issued applicant shall submit executed Non-Residential sewer Use Certification form listing aPI new plumbing fixtures. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206)43M'g35U 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH-IN GAS PIPING 8005 ROUGH-IN PLUMBING 9001 UNDERGROUND CITY OF TUKWILO Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: Tenant Name: /$Zi5' Ply King Co Assessor's Tax No...2' / e / — G4, 70 Suite Number: Name: Address: City: State: Zip: Floor: New Tenant: ,� Yes ❑.. No ��_k�[ 1e 3y 1,1 Company Name: d;� a t. Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ Q K1 1 y Scope of Work (please provide detailed information): £,4,%/ ArrtRael, Building Use (per Int'1 Building Code): ACCMLO�i Occupancy (per Int'1 Building Code): Utility Purveyor: Water: H:\Applications\Porms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docc Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures an Fixture Type Qty Bathtub or combination bath/shower `� Dishwasher, domestic with independent drain // Shower, single head trap 0. Sinks 2 i , ,. " I �A Rain water system — per / drain (inside building)0 Grease interceptor for commercial kitchen (>750 gallon capacity) / Each additional medical gas inlets/outlets greater than 5 0 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) as piping outlets being installed and the quant. below: Fixture Type Qty Bidet 6 Drinking fountain or water cooler (per head) // �7 Lavatory /C/ 4P Urinal / Water heater and/or vent Repair or alteration of drainage or vent piping / Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial P:7 Receptor, indirect waste Wash fountain 4P Water closet '7 industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outletszy, Fixture Type Qty; Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJUR : Y THE LA S OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 E Signature: AGENT: Date: OK:o7 Print Name: � %J Day Telephone: 9) l Wie' I Mailing Address: Lai irfl C J 42 &) A ,�.?/?/(e. City State H:\Appliations\Fornu-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 eceipt Mumbai R 392 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $12,106.99 D18-0010 Address: 15450 NELSON PL Apn: 2423049090 $10,958.33 DEVELOPMENT $10,529.61 PERMIT FEE R000.322.100.00.00 0.00 $8,574.43 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 STRUCTURAL CONSULTANT R000.345.830.01.00 0.00 $1,950.68 TECHNOLOGY FEE $428.72 TECHNOLOGY FEE R000.322.900.04.00 0.00 $428.72 M18-0006 Address: 15450 NELSON PL Apn: 2423049090 $501.87 MECHANICAL $501.87 PERMIT ISSUANCE BASE FEE 8000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $468.72 ✓ PG18-0004 Address: 15450 NELSON PL Apn: 2423049090 $646.79 GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE 8000.322.100.00.00 0.00 $66.30 PLUMBING $516.54 PERMIT FEE R000.322.100.00.00 0.00 $483.39 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $30.80 TECHNOLOGY FEE R000.322.900.04.00 0.00 $30 80 TOTAL FEES PAID BY RECEIPT: 813926$12,106.99 Date Paid: Monday, March 05, 2018 Paid By: LOOMIS Pay Method: CHECK 2888597 Printed: Monday, March 05, 2018 1:03 PM 1 of 1 PermitTRAK $158.62 PG18-0004 Address: 15450 NELSON PL Apn: 2423049090 $158.62 Credit Card Fee Credit Card Fee R000.369.908.00.00 0.00 GAS PLAN CHECK FEE R000.322.103.00.00 0.00 PLUMBING $4.62 $4.62 $24.86 $24.86 $129.14 PLAN CHECK FEE R000.322 103 00.00 0.00 $129.14 TOTAI. FEES PAID BY RECEIPT: 813260' Date Paid: Tuesday, January 09, 2018 Paid By: PAUL HARRINGTON Pay Method: CREDIT CARD 054867 Printed: Tuesday, January 09, 2018 12:31 PM 1 of 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6a-apy PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Levni (5 , Tx of Inspection: p Adidr niersau ez Date ixeC ed: --.a Special Instructions: Date Wajajed: - i (a.me P'rn* Request-) h11 -14.L Phone No: 509- 7/Y- &301 Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: i Loory-ITs T e of Inspection: 1ti--'-^ &rou14:6-- Date Called: Address: 15'/5O KeLSONatZe. Special Instructions: I. GAS 17);p;.% rrgr- 5 RT tot' 5 Date Wanted: -7-lq-zoie a.m. lc!" Reguester: — Phone No: Phone l—seiff -71 ii - 430 I ,Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Cie • Inspector: wra Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 12/2/2018 0 City of Tukwila Department of Community Development PAUL HARRINGTON 3421 S HENRY RD GREENACRES, WA 99016 RE: Permit No. PG 18-0004 LOOMIS 15450 NELSON PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/15/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/15/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, chelle Ripley Permit Technician File No: PG18-0004 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0004 PROJECT NAME: LOOMIS SITE ADDRESS: 15450 NELSON PL X Original Plan Submittal Response to Correction Letter # DATE: 01/09/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AS Awc Building Division II S WC Fifai8 Public Works Fire Prevention Structural LI Planning Division Permit Coordinator LIj u PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/11/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/08/18 Approved Corrections Required 111 Approved with Conditions e LI Denied 111 (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW 0 Staff Initials: 12/18/2013 ACE COMMUNICATION SERVI I INC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I A -Z Index Help Page 1 of 2 ARCH Workplace Rights Trades & Licensing ACE COMMUNICATION SERVICES INC Owner or tradesperson Principals FORRESTER, JOSHUA I D Doing business as ACE COMMUNICATION SERVICES INC WA UBI No. 601 786 886 PO BOX 1286 ROSEBURG, OR 97470 503-807-1477 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no, ACECOSI036KL Effective — expiration 05/13/1997— 09/29/2019 Bond Hudson Insurance Company Bond account no. 10052017 $12,000.00 Received by L&I Effective date 01/27/2017 04/30/2017 Expiration date Until Canceled Bond history Insurance Ohio Cas Ins Co Policy no. BKS54944225 $1,000,000.00 Received by L&I Effective date 09/15/2016 10/28/2014 Expiration date 10/28/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LSI Tax debts ......................... _ .......... No LSI tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve httns://securelni.wa. aov/verify/Detail.aspx?UBI=601786886&LIC=ACECOSI036KL&SAW= 3/27/2018 ACE COMMUNICATION SERVICINC License Violations No license violations during the previous 6 y riod. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account Is closed. 115,285-00 Doing business as ACE COMMUNICATIONS SERVICES IN Estimated workers reported N/A L&I account contact T1 / LINDSEY BOOTH (360)902-5596 - Email: B000235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................................................. No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 CO Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni .wa.gov/verify/Detail.aspx?UBI=601786886&LIC=ACECOSI036KL&SAW= 3/27/2018 PLUMBING LEGEND SYMBOL --NP Onlit T 010 - ---CSW ----HSW---- - LCW - ----LHW an Ing --180'---- RO DI DW G G(#PSI) —LPG 0 F SS PS SD ARW - II--IIARW� - -ARV- - - - - I- --11ARV1- - -I - 1W -{}--11 IW I----I-- RWL ---RWL--I- OWL I CD 4----I- CD -I—# CD 11---I- GW -I-11 GW 1----F- - FO COTG - I-O COW DEFINITION COLD WATER HOT WATER HOT WATER RETURN NON -POTABLE COLD WATER TEMPERED HOT WATER COLD SOFT WATER HOT SOFT WATER LAB COLD WATER LAB HOT WATER HOT WATER IN/TEMP. INDICATED HOT WATER HEAT TRACED REVERSE OSMOSIS WATER DEIONIZED WATER DISTILLED WATER NATURAL GAS (BELOW 1PSI) NATURAL GAS (ABOVE 1PSI) LIQUID PROPANE GAS OXYGEN FIRE PROTECTION PIPING SANITARY SEWER (SITE) PUMPED SANITARY SEWER (SITE) STORM DRAIN (SITE) WASTE PIPING WASTE PIPING (BELOW) VENT PIPING VENT PIPING BELOW GRADE ACID RESISTANT WASTE PIPING ACID RESISTANE WASTE PIPING (BELOW) ACID RESISTANT VENT PIPING ACID RESISTANT VENT PIPING (BELOW) INDIRECT WASTE PIPING INDIRECT WASTE PIPING (BELOW) RAIN WATER LEADER PIPING RAIN WATER LEADER PIPING (BELOW) OVERFLOW RAIN WATER LEADER PIPING OVERFLOW RAIN WATER LEADER (BELOW) CONDENSATE DRAIN PIPING CONDENSATE DRAIN PIPING (BELOW) GREASE WASTE PIPING GREASE WASTE PIPING (BELOW) CLEAN OUT TO GRADE CLEAN OUT TO FLOOR ABBREV. CW HW HWR NPCW NW CSW HSW LCW LHW HTRHW RO DI DW NG NG(#PSI) LPG 0 FP SS PS SD W W V V ARW ARW ARV ARV IW IW RWL RWL OWL OWL CD CD GW GW COTG COTF PLUMBING/PIPING SYMBOLS II —0 —0-- ---®-- ED ELBOW UP ELBOW DOWN TEE UP TEE DOWN CONCENTRIC REDUCER/INCREASER ECCENTRIC REDUCER/INCREASER UNION RISE/DROP IN PIPE RISE/DROP IN PIPE & 90' TURN VENT THRU ROOF CAP CLEAN -OUT (WALL) CLEAN -OUT (FLUSH TO FLOOR OR GRADE) FLOOR DRAIN CIRCULATING PUMP (POINTS IN DIRECTION OF FLOW) VALVE (AS INDICATED OR SPECIFIED) CHECK VALVE PRESSURE & TEMPERATURE (RELIEF VALVE) PRESSURE REDUCING VALVE (POINTS TOWARDS LOW PRESSURE) GAS VALVE SOLENOID VALVE HOSE BIBB CIRCUIT SETTER VALVE BOX W/ VALVE (AS SPECIFIED) CONNECTION TO EXISTING EXTENSION & CONTINUATION ADDITIONAL SYMBOLS �-- SECTION DESIGNATION -••— SHEET NUMBER -al-- DETAIL NUMBER --�— SHEET NUMBER WSEC COMPLIANCE 1. ELECTRIC WATER HEATERS LOCATED IN UNCONDITIONED SPACES OR ON CONCRETE FLOORS SHALL BE SEPARATED FORM THE SUPPORTING SURFACE WIN R-10 INSULATION AS DESCRIBED IN SECTION C404.4 OF THE WSEC. 2. DOMESTIC HOT WATER CIRCULATION PUMPS SHALL BE SHUT DOWN DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION 1442 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 3. PIPE INSULATION - PER WSEC C404.6. FOR AUTOMATIC -CIRCULATING HOT WATER AND HEAT -TRACED SYSTEMS, PIPING SHALL BE INSULATED WITH NOT LESS THAN 1 INCH (25 MM) OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/H • FT2 • 'F (1.53 W PER 25 MM/M2 • K). 4. PROVIDE HEAT TRAP ON SUPPLY AND DISCHARGE PIPING FROM WATER HEATER AS REQUIRED IN SECTION C404.4 OF WSEC. RHEEM SP2003 OR EQUAL. 5. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE AS REQUIRED BY SECTION C408.1.3 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 6. COMMISSIONING: MECHANICAL EQUIPMENT AND ASSOCIATED CONTROLS MUST BE COMMISSIONED IN ACCORDANCE WIN THE 2012 NREC REQUIREMENTS (SECTION C408) INCLUDING BUT NOT LIMITED TO; A COMMISSIONING PLAN, A PREUMINARY COMMISSIONING REPORT, FINAL COMMISSIONING REPORT AND COMPLETION OF THE 2012 NREC COMMISSIONING COMPLIANCE CHECKLIST. A COPY OF THE COMMISSIONING COMPLIANCE CHECKLIST IS REQUIRED TO BE GIVE TO THE LOCAL BUILDING OFFFICIAL 7. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO NE OWNER AS REQUIRED BY SECTION C408.1.3.2 OF THE WSEC. AS MINIMUM, NE MANUALS SHALL INCLUDE: • SUBMITTAL DATA. • OPERATION AND MAINTENANCE DATA FOR EQUIPMENT. • NAMES AND ADDRESSES OF SERVICE AGENCIES. • HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION. • NARRATIVE OF HOW SYSTEM IS INTENDED TO OPERATE. 9. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING SHALL BE SUBMITTED TO THE OWNER AS REQUIRED BY SECTION C408.1.2 OF THE WSEC. PLUMBING FIXTURE SCHEDULE SYMBOL cap DESCRIPTION WATER CLOSET LAVATORY WALL HUNG FLOOR DRAIN DOUBLE COMPARTMENT SINK FREEZLESS ROOF HYDRANT MANUFACTURER AND CATALOG # CADET: III FLOWISE AMERICAN STANDARD LUCERNE 0355.012 JR SMITH FIG 2005 JUST STYLUS DL-2233-A-GR WOODFORD MODEL RHY1-MS TRIM & DETAIL REFERENCES SUPPLY, STOP, FIXTURE CARRIER, ELONGATED SEAT, AMERICAN STANDARD 7385.003.002 ROUND STRAINER, NICKEL BRONZE STRAINER, TRAP PRIMER CONNECTION MOEN CA87685, 1.5 GPM VACUUM BREAKER CONNECTIONS HW 0.10 1/2" 1 /2" 1" CW 1 /2" 1 /2" 1/2" W 4" 1-1/2" 2" V 2" 1-1/2" 2" .000 NOTES MOUNT TO COMPLY WITH ADA REQUIREMENTS. SEE ARCHITECTURAL PLANS FOR LOCATION OF ADA FIXTURES INSULATE P-TRAP & EXPOSED H.W. UNES SEE DRAWINGS FOR DRAIN WASTE AND VENT SIZE BASKET STRAINER, TAIL PIECE, P-TRAP, SUPPLIES, STOPS, ARCHITECTURAL PLANS FOR LOCATION OF ADA FIXTURES, PROVIDE INSULATION ON SUPPLIES AND DRAIN ON ADA FIXTURES, PROVIDE MANUAL MIXING VALVE TO LIMIT HOT WATER SUPPLY TO 105F. PROVIDE BADGE 100 1/3 HP CONTINUOUS FEED GARBAGE DISPOSAL CONNECT 1/8" DRAIN LINE TO HYDRANT AND PIPE TO NEAREST DRAIN. SE Ar,f l PERMITli7OUIRPD FOR: i r ^ hanicai • Iectrical O Plumbing 0 Gas Piping C;ty of Tukwila BUILDING DIVISION REVISIONS No chances shall be rn^� the of work r, the .� f ite � i'.it �vrior.apN ra J4l o! E=Odiino Division. J NOTE: Revisions will require a ner✓ Wan submittal and may include addition plan review fees. FILE COPY Permit No. "PC-1 (e- OOO s f Plan review approval is subject to errors and omissions. Approval of construction docum = { does not authorize the violation of any adopted = or ordinance. Receipt of approved Field ' . pyt d, . '., s is acknowledged: By: Date* City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 2018 City of Tukwila BUILDING.DIVi.S RECEIVED JAN 092010 WSW TUKWILA PUBLIC WORKS RECEIVED CITY OF TUKWILA JAN 092010 PERMIT CENTER architecture studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 Engineering REVISIONS building remodel for: loomis US 15450 nelson place. tukwila, wa 98188 P0.01 PLUMBING NOTES & LEGENDS PG'S 0001+: SHS NO. DATE 1718 ADE 01-08-18 I MAK CC 24ie robot lwn,y *boor LOBBY 101 INTERVIEW 103 OFFICE 104 J LUNCH ROOM 105 r LOCKERS 102 0 0 EXIST TOILET EXIST TOILET CONNECT NEW WASTE PIPING TO EXISTING 4 WASTE PIPING. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING 4" OR LARGER WASTE UNE IN THIS AREA 1 DATA ELEC 112 HALL 115 STAIR 201 MEN 117 MEN 117A 4"W UP IN WALL. SEE P1.02 FOR CONTINUATION HALL 116 U 7WA TOSTE L-1 4"W&2"V UP TO WC-1 (TYP-6) -i HALL 116 ELEV 202 ELEV ROOM 114 \ J WOMEN 118 4" W 21'W W/PTRAP TO FD-1 & 2"V UP COIF 0,-4" W Q WOMEN 118A L-1 2"W UP TO WCO ABOVE FLOOR & UP TO L-1 (TYP-2) 2 (SW SECTION SCALE: 1/4" = 1'-0* NEW - FOUNDATION PLAN PLUMBING NORTH GENERAL NOTES 1. SLOPE ALL SEWERS 1/4" PER FOOT WHEN POSSIBLE. NO UNES SHALL BE LESS THAN 1 /8" PER FOOT. 2. FOR THE PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE DIAGRAMMATIC AND FOR DESIGN INTENT ONLY. CONTRACTOR MUST VERIFY ALL DIMENSIONS BY FIELD MEASUREMENT BEFORE BEGINNING ANY FABRICATION OR CONSTRUCTION. 3. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE CURRENT STATE AND LOCAL PLUMBING CODES AND ORDINANCES. 4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 5. COORDINATE EXACT LOCATION OF PIPING WITH OTHER TRADES. 6. ALL SOIL PIPING SHALL BE SCH 40 PVC WITH SOLVENT FITTINGS OR DWV CAST IRON WITH NO HUB FITTINGS. 7. ALL VENT PIPING SHALL BE ABOVE FLOOD RIM LEVEL OF HIGHEST FIXTURE BEFORE CONNECTION TO COMMENT VENTS. 8. HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL AND EACH RUN OF PIPING, THAT IS MORE THAN 100' IN TOTAL DEVELOPED LENGTH. CLEANOUTS SHALL BE PROVIDED IN A DRAINAGE UNE FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION EXCEEDING ONE HUNDRED THIRTY FIVE DEGREES. KEYED NOTES (1 SAW CUT FLOOR FOR WASTE AND VENT PIPING. PATCH WHEN INSTALLED. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 201B City o i ukwiia KEY PLAN R', EIVED CITY CGF TUKWILA JAN 0 9 2016 PERMIT CENTER architecture Studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 Kartchner Engineering REVISIONS .ti.. .�►• y •.�+. .. . Y • JAN 1 28 building remodel for: loomis US 15450 nelson place tukwila, wa 98188 P1.01 PLUMBING FOUNDATION SHS NO. DATE 1718 I ADE 01-08-18 I MAK OD 2018 math tarry studios 1" G EXISTING 2 PSI GAS METER. GAS METER O AND SERVICE BY LOCAL GAS AUTHORITY. VERIFY EXACT LOCATION. /rt \` j PROVIDE NEW 2" HEADER. ROUTE NEW 1" GAS— UNE TO NEW GAS FIXTURES. CONNECT EXISTING GAS UNE TO NEW 2" HEADER. LOBBY 101 INTERVIEW 103 OFFICE 104 J LUNCH ROOM 105 E L 1" GAS UP LOCKERS 102 a 0 EXIST TOILET 1/2"HW &--1 CW AND 2"W UP TO SINK ABOVE 2 g & TO 2"W UP TO WCO ABOVE FLOOR & UP TO L-1— (TYP-2) EXIST TOILET 1/2" CW UP TO WC-1 1CW 2" W UP TO FD-1 1/2"HW & CW AND 1-1/2"W UP TO LAV 1/2"HW&CW UP TO L-1 DATA ELEC 112 H ALL 115 STAIR 201 2"V UP IN WALL ABOVE SEE P1.02 FOR CONT. MEN 117 CO 3/4"HW U 4" W UP TO WC-1 10111. MEN 117A 3/4" HW © L_ 1" CW UP — SEE P2.01 TO CONFIRM LOCATION HALL 116 L 1/2" HW & HCWTOL-1 ELEV 202 ELEV ROOM 114 1" CW 1" CW WOMEN t 118 3/4" HW 3/4" HW H.W. ! L-1 4"W ON IN WALL SEE P1.01 FOR CONT. (1/2" HW 3/4" CW TO WC-1 (TYP-6) WOMEN 118A 2"V DN TO LAVS (TYP-2) HW & CW TO L-1 (TYP-4) _1 2 1 CO 3 (SW SECTION) NEW - MAIN FLOOR PLAN PLUMBING SCALE: 1/4" = 1'—O" NORTH GENE L NOTES 1. 2. SLOPE ALL SEWERS 1/4" PER FOOT WHEN POSSIBLE. NO UNES SHALL BE LESS THAN 1/8" PER FOOT. FOR THE PURPOSES OF CLEARNESS AND LEGIBIUTY, DRAWINGS ARE DIAGRAMMATIC AND FOR DESIGN INTENT ONLY. CONTRACTOR MUST VERIFY ALL DIMENSIONS BY FIELD MEASUREMENT BEFORE BEGINNING ANY FABRICATION OR CONSTRUCTION. 3. ALL VAIRK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE CURRENT STATE AND LOCAL PLUMBING CODES AND ORDINANCES. 4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 5. COORDINATE EXACT LOCATION OF PIPING WITH OTHER TRADES. 6. ALL SOIL PIPING SHALL BE SCH 40 PVC WITH SOLVENT FITTINGS OR DWV CAST IRON WITH NO HUB FITTINGS. 7. ALL VENT PIPING SHALL BE ABOVE FLOOD RIM LEVEL OF HIGHEST FIXTURE BEFORE CONNECTION TO COMMENT VENTS. 8. HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100' IN TOTAL DEVELOPED LENGTH. CLEANOUTS SHALL BE PROVIDED IN A DRAINAGE UNE FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION EXCEEDING ONE HUNDRED THIRTY FIVE DEGREES. KEYED NOTES O EXISTING 2 PSI GAS METER. COORDINATE WITH LOCAL GAS AUTHORITY ON EXISTING METER. NEW GAS LOAD = 590,000 BTUH ASSUMED EXISTING LOAD =580,000 BTUH O WASTEUNE SHOWN IS FOR FIXTURES ON MEZZANINE L Q3 CONNECT NEW 1" COLD WATER UNE TO EXISTING COLD WATER UNE. ASSUME 50' OF 1" PIPING. ® CONNECT NEW 3/4" HOT WATER UNE TO EXISTING HOT WATER UNE. ASSUME 50' OF 3/4" PIPING. rif KEY PLAN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 0115, UV of Tukwila BUtt:.Dll'C. RECEIVED CI i (Or fUKWILA JAN 0 9 2018 PERMIT CENTER architecture studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 H H Engineering REVISIONS W Ct JAN 152L 3 building remodel for: loomis US 15450 nelson place tukwila, wa 98188 P1.02 PLUMBING MAIN FLOOR SHS NO. DATE 1718 I ADE 01-08-18 MAK 00 2018 south bevy dodos <C> (6) ROOF BELOW 1-1/2"V DN AND 1/2"HW & CW FROM BELOW TO LAV (TYP-2) 2"V DN TO FD-1 (TYP-2) 2"V DN & 1/2"CW FROM BELOW TO WC (TYP-2) 2"V DN & 1/2"CW FROM BELOW TO WC (TYP-2) v 2. ROOMS BELOW STAFF MEN ELEV 202 1 1" CW DOWN IN WALL BRANCH L1 MANAGER 205 L RECEPTION 204 Min r I I L_ IIII IIII ! IICIIIICI1'�1 IMMO 1" CW UP TO HB ON ROOF VAULT BELOW (fAilf SECTION) NEW -MEZZANINE FLOOR PLAN -PLUMBING SCALE: 1/8" = 1'—O" NORTH GENERAL NOTES 1. SLOPE ALL SEWERS 1/4" PER FOOT WHEN POSSIBLE. NO UNES SHALL BE LESS THAN 1/8" PER FOOT. 2. FOR THE PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE DIAGRAMMATIC AND FOR DESIGN INTENT ONLY. CONTRACTOR MUST VERIFY ALL DIMENSIONS BY FIELD MEASUREMENT BEFORE BEGINNING ANY FABRICATION OR CONSTRUCTION. 3. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE CURRENT STATE AND LOCAL PLUMBING CODES AND ORDINANCES. 4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 5. COORDINATE EXACT LOCATION OF PIPING WITH OTHER TRADES. 6. ALL SOIL PIPING SHALL BE SCH 40 PVC WITH SOLVENT FITTINGS OR DWV CAST IRON WITH NO HUB FITTINGS. 7. ALL VENT PIPING SHALL BE ABOVE FLOOD RIM LEVEL OF HIGHEST FIXTURE BEFORE CONNECTION TO COMMENT VENTS. 8. HORIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANGOIT AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100' IN TOTAL DEVELOPED LENGTH. CLEANOUTS SHALL BE PROVIDED IN A DRAINAGE UNE FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION EXCEEDING ONE HUNDRED THIRTY FIVE DECREES. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 ?fir. City of Tukwila BUn IDIN1 DJ .Z,I KEY PLAN RECE VED CITY OF 1PUKWILA JAN 09 2018 PERMIT CENTER architecture studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 Engineering REVISIONS W H ct W t. Jiktit 2019 building remodel for: loomis US 15450 nelson place tukwila, wa 98188 P2.01 PLUMBING MEZZANINE FLOOR SHS NO. DATE 1718 I ADE 01-08-18 I MAK Ce 2t)18 south harp stocks 1" GAS DOWN ROOF BELOW 1" G 1" GAS — UP 15' TO ROOF GAS REGULATOR 2PSI TO 7" WC AT 590 MBH /1" G G(2PSI) 3/4 " GAS UNE TO RTU-1 3/4" G 3/4 " GAS UNE TO RTU-3 1-1/2" G 220' PIPE LENGTH COLUMN IN CO DE USED FOR SIZING AT 2 EQUIPMENT MBH R1U-1 RTU-2 RTU-3 350 120 TOTAL: 590 MBH 1 1 /4" MAIN ® 2 PSI 1-1/2" 10 RTU-3 120 MBH COORDINATE NEW GAS METER AND SERVICE WITH LOCAL GAS COMPANY 1-1/4" 1" TO EXISTING FIXTURES RTU-2 350 MBH 1-1/2" 3/4" 1-1/2" GAS PRESSURE REG. 3/4" 2 I NEW: GAS CALC & ISO SCALE: NOT TO SCALE det#: 3/4"CW DN THRU ROOF SEE P1.02 FOR CO NTINUATKON RTU-1 120 MBH 1-1/2 " GAS UNE TO RTU-2 GENE ; L NOTES 1. SLOPE ALL SEWERS 1 /4" PER FOOT LIEN POSSIBLE. NO UNES SHALL BE LESS THAN 1/8" PER FOOT. 2. FOR THE PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE DIAGRAMMATIC AND FOR DESIGN INTENT ONLY. CONTRACTOR MUST VERIFY ALL DIMENSIONS BY FIELD MEASUREMENT BEFORE BEGINNING ANY FABRICATION OR CONSTRUCTION. 3. ALL WORK SHALL BE COMPLETED IN STRICT ACCORDANCE WITH THE CURRENT STATE . AND LOCAL PLUMBING CODES AND ORDINANCES. 4. CONTRACTOR SHALL INSTALL ALL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 5. COORDINATE EXACT LOCATION OF PIPING WITH OTHER TRADES. 6. ALL SOIL PIPING SHALL BE SCH 40 PVC WITH SOLVENT FITTINGS OR DWV CAST IRON WITH NO HUB FITTINGS. 7. ALL VENT PIPING SHALL BE ABOVE FLOOD RIM LEVEL OF HIGHEST FIXTURE BEFORE CONNECTION TO COMMENT VENTS. 8. HGRIZONTAL DRAINAGE PIPE SHALL BE PROVIDED WITH A CLEANOUT AT ITS UPPER TERMINAL, AND EACH RUN OF PIPING, THAT IS MORE THAN 100' IN TOTAL DEVELOPED LENGTH. CLEANOUTS SHALL BE PROVIDED IN A DRAINAGE LINE FOR EACH AGGREGATE HORIZONTAL CHANGE OF DIRECTION EXCEEDING ONE HUNDRED THIRTY FIVE DEGREES. (SW SECTION) ROOF PLAN.- PLUMBING SCALE 1 /8" = 1'-0" NORTH 7� REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17n15 City of Tukwila BUILDI JAN 0 9 2018 architecture studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 Kartchner REVISIONS W H a_ ct JAM1 lb 280 building remodel for: loomis US 15450 nelson place tukwila, wa 98188 P3.01 PLUMBING ROOF KEY PLAN PERMIT CENTER SHS NO. DATE 1718 I ADE 01-08-18 MAK GC 2D15 south bony *don 10 PIPE DIAMETERS MINIMUM TEST TEE DIRT LEG LOWER PRESSURE GAS PIPING TO UNIT OR UNITS. SEE PLANS FOR SIZE AND ROUTING. CONNECTION TO EQUIPMENT SHALL BE HARD PIPED ONLY. GAS PRESSURE REGULATOR SEE SCHEDULE FOR INLET AND OUTLET PRESSURES. UNION (TYP) IGAS PRESSURE REGU SCALE: NOT TO SCALE 2 ALL FLOOR DRAINS MUST HAVE A TRAP PRIMER 6" REMOVABLE CAP HIGHER PRESSURE GAS PIPING FROM MAIN. SIZE PIPE AND ROUTE PIPE AS SHOWN ON DRAWINGS GAS SHUT—OFF TOR DETAIL COLD WATER MAIN. SHUT OFF VALVE 1/2" TRAP PRIMER VALVE VACUUM BREATHER PORTS. FIN. FLOOR SEWER GASES FLOOR DRAIN & TRAP PRIMER DETAIL SCALE: NOT TO SCALE 1 AS C UNIT DIRT LEG REMOVABLE CAP ECTI SCALE: NOT TO SCALE FLOOR DRAIN—� STRAINER AS SCHEDULED FINISHED FLOOR SURFACE CV • TRAP PRIMER PIPING LEAD AND OAKUM OR NEOPRENE GASKET P—TRAP iPIPE SIZE AS INDICATED ON THE DRAWINGS 0SI 000 6" TAIL. UNION GAS SHUT—OFF VALVE CERAMIC TILE AND SETTING BED SLOPE TO DRAI DRAIN BODY POURED IN PLACE NOTE: IF INDICATED FLOOR FINISH DOES NOT APPLY, REFER TO ARCHITECTS DRAWING FOR FINISH TYPE. FLOOR DRAIN DETAIL ROUTE AS SHOWN ON DRAWINGS WATERPROOF MEMBRANE CONCRETE FLOOR SLAB CLAMP PAN TIGHTLY INTO DRAIN COLLAR PIPE SIZE AS INDICATED ON MECHANICAL DRAWINGS SCALE: NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 2010 City of Tukwila RECEIVED CITY OF TUKWILA JAN 09 2018 architecture studios planning development 3421 south henry road greenacres wa 99016 p 509.714.6301 www.southhenry.com 2/20/18 0 Kartchner Engineering REVISIONS JAN ? ti 2V2 building remodel for: loomis US 15450 nelson place tukwila, wa 98188 P4O1 PLUMBING SCHEDULES & DETAILS PERMIT CENTER SHS NO. DATE 1718 I ADE 01-08-18 I MAK 2013 south hear dodos