Loading...
HomeMy WebLinkAboutPermit PG18-0014 - KING COUNTTY METRO - REMOVE OLD PARTS WASHING TANK AND REPLACE WITH NEW TANKKING COUNTY METRO 12400 E MARGINAL WAY S PGI 8-0014 Parcel No: Address: r\ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 7340600480 12400 E MARGINAL WAY S Project Name: KING COLJ,NTTY METRO Permit Number: Issue Date: Permit Expires On: PG 18-0014 2/28/2018 8/27/2018 Owner: Name: BANK OF CHINA NEW YORK Address: 1045 AVE OF THE AMERICAS , NEW YORK, WA, 10018 Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CHARLES WEEKS 106 55 AVE E , FIFE, WA, 98424 NORDIC CONSTRUCTION INC 106 55TH AVE E , FIFE, WA, 98424- 2426 NORDICI110LZ Phone: (253) 202-7579 Phone: (253) 922-3100 Expiration Date: 3/22/2020 DESCRIPTION OF WORK: REMOVE EXISTING OLD PARTS WASHING TANK AND REPLACE WITH NEW TANK Valuation of Work: $14,000.00 Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Fees Collected: $147.85 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. AH provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulatingconstruction or the perform ice -of work. I am authorized to sign and obtain this development permit aQ agr��hee conditionst ct� hed to this permit. Date: Z 2 Signatur` -- t Print N�»ie t t� ` f W This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shalt be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING \_. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:11www .TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: /14 GiV1)" OOP-fr Date Application Expires: 0 • e • (16 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Sfl E LOCATION King Co Assessor's Tax No.: 7340600421 Site Address: 12100 East Marginal Way S, Tukwilla, 98168 Suite Number: Floor: Tenant Name: King County Metro New Tenant: 1:1 Yes ..No PROPERTY OWNER Name: Charles Weeks Name: King County -Transit City: Fife State: WA Zip: 98424 Address: 401 5th Ave Email: charles@nordicconst.com City:State: Seattle wa Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Charles Weeks Address: 106 55th Ave E City: Fife State: WA Zip: 98424 Phone: (253) 202-7579 Fax: (253) 922-4594 Email: charles@nordicconst.com PLUMBING CONTRACTOR INFORMATION Company Name: Nordic Construction Inc Address: 106 55th Ave E City: Fife State: WA Zip: 98424 Phone: (253) 922-3100 Fax: (253) 922-4594 Contr Reg No.: NORIDCII IOLZExp Date: 03/22/2018 Tukwila Business License No.: 09-2386 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): REMOVE EXISTING OLD PARTS WASHING TANK AND REPLACE WITH NEW TANK .1-3-770tvw jL-OV Building Use (per Intl Building Code): Bus Terminal Occupancy (per Int'l Building Code): Utility Purveyor: Water: King County District 125 H:\ApplaflonsForms-ApplicaTians On Linel2011 Applications \Plumbing Permit Application Revised 8-9-11.docs Revised: August 2011 bh Sewer Valley View Sewer District Page 1 of 2 Indicate tyRepf plmbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Tyke Qty Bathtub or comb eation g •`. bath/shower .. Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) X Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment X Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping X Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by Iimitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Charles Weeks, Nordic Construction Inc. Day Telephone: (253) 922-3100 Mailing Address: 106 55th Ave E Fife WA 98424 City State Zip HaApptications\Forms-Applications On Line12011 Appticat ions\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $946.79 M18-0024 Address: 12400 E MARGINAL WAY S Apn: 7340600480 $827.37 MECHANICAL $787.97 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $754.82 TECHNOLOGY FEE $39.40 TECHNOLOGY FEE R000.322.900.04.00 0.00 $39.40 PG18-0014 Address: 12400 E MARGINAL WAY S Apn: 7340600480 $119.42 PLUMBING $113.73 PERMIT FEE R000.322.100.00.00 0.00 $80.58 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $5.69 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13889 R000.322.900.04.00 0.00 $5.69 $946.79 Date Paid: Wednesday, February 28, 2018 Paid By: NORDIC CONSTRUCTION Pay Method: CHECK 58393 Printed: Wednesday, February 28, 2018 12:39 PM 1 of 1 CRWSYSTEMS \ DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY :: PAID $225.42 M18-0024 Address: 12400 E MARGINAL WAY S Apn: 7340600480 $196.99 MECHANICAL $196.99 PLAN CHECK FEE 8000.322.102.00.00 0.00 $196.99 PG18-0014 Address: 12400 E MARGINAL WAY 5 Apn: 7340600480 $28.43 PLUMBING $28.43 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13748 R000.322.103.00.00 0.00 $28.43 $225.42 Date Paid: Thursday, February 08, 2018 Paid By: NORDIC CONSTRUCTION Pay Method: CHECK 58314 Printed: Thursday, February 08, 2018 9:57 AM 1 of 1 aF a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'O18 -00H 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: K, I 6/19 rc,G.,-‘i-y Me4/6 Type of Inspection: T b i 11_ Fi 'JAL Address: 42q0C3 E. NI, 6..yq i este-EMI** s • Special Instructions: `..) Date Wanted: p.m. Requester: Phone No: kVA Approved per applicable codes. Corrections required prior to approval. 0 MENTS: nspector: Date: *20 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Calk to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P618- 0 °Pi Project: Li"ItA1/1, ekyo Typee,..< Inspection 6 1-11—lki,ALe 1 Egli7f - Alcess: 1 /2110D . MayliliAL tdv k Date Called: ,—, Special Instructions: i Date Wanted: Lis Z— . . p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. 0 ENTS: z hioc_ u_enLe,r. *1-6 kllaPt) (pecked frvi,' "Sp r_Z;I:76 Inspector7?jo Date: 2- 2X -'J& REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cett to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 T26/8-coi PrOjgct: i i 0 iia- away /1177W Type of Inspection: fioaaty- 4/ Pi vot siNq- Address: Date Called: Special Instructions: Gfiov,M0 14/0,41< ,couG.H--dv A. 7)V6- Date Wanted: 3 -A /6 0 p.m. Requester: Phone No: 72 Approved per applicable codes. Corrections required prior to approval. COMMENTS: tita4/11. 701Te'l J11 (IX"14,) Xeu-51(21/1 5- Aleld Ce/13 Inspector: .3 e(2 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permitiPos -tom INSPECTION NO. PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Kio5 Cotmnivi vt k-Nro Type of Inspection: Ground tOor-le, Address: awn E. MA ( A ect:CC:51,-) 41 P Lon 6 i N Special Instructions: Date Wanted: 2. . . P•m• Requester: Phone No: ElApproved per applicable codes. 4 Corrections required prior to approval. COMMENTS: rbut-nd, NA/Or ect:CC:51,-) L its . • 134 — 0 elcsFa D. . cfp4-a_ez Aicwts‘th- -o 4‹, Knce* Orts;-le Inspector: Date: giz.4 Acte, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 5 10 z TYPICAL SECTION AND DETAIL REFERENCING SYSTEM DRAWING NUMBERING SYSTEM KEY: S 11910 ST. (1) PIE SECTION IS CUT ON DRAWING A101; SECTION LETTER ELEVATION LEITER DRAWING ON WHICH SECTIOMELEVATION APPEARS. (2) ON DRAWING 0105 THIS SECTION IS DENTIFIED: SECTION SCALE: SECTION LETTER DRAWING ON WHICH SECTION WAS Al .04r TAKEN. (3) DETAILS ARE CROSS-REFERENCED IN A SIMILAR MANNER, EXCEPT TOT DETAILS ARE IDENTIFIED BY NUM3ERS RATHER THAN BY LET TERS. V CINITY MAP NOT TO SCALE FIAELAND ,00DMOND PRESTON . LE VOUSO 0 Dzs IA ND T. ALGONA • SIC - DISCIPLINE G GENERAL S STRUCTURAL M MECHANICAL E ELECTRICAL AREA LOCATION (FOR PROJECTS WITH MULTIPLE LOCATIONS) Pogo Sheet Number Number 1 G0.31 2 S0.01 3 M01.0'. 4 MD3.01 5 M05.01 6 5,41.31 7 0.13.01 8 515.01 9 M5.02 10 517,02 11 ED1.01 12 E0102 13 03.01 14 03.02 15 06.01 16 E6.02 DISCIPLINE DESIGNATOR SEPARATOR DESIGNATED CATEGORY 0 GENERAL PLANS 2 ELEVATIONS 3 SECTIONS 4 ENLARGED PLANS 5 DETAILS 6 SCHEDULES & DIAGRAMS 2 C1.01 SHEET LIST GENERAL GENERAL VICINITY MAP; LOCATION MAP, S7FE MAP AND -Si -1E01 LIS STRUCTURAL STRUCTURAL NOTES MECHANICAL MECHANICAL DEMOLITION FLOOR PLAN MECHANICAL DEMOLTION FLOOR LEVEL SECTION CUT MECHANICAL DEMOLITION PHOTO DETAILS MECHANICAL FLOOR PLAN FLOOR LEVEL SECTION CUT MECHANICAL DETAILS NATURAL GAS SYSTEM BASIS Of DESIGN INSTALLATION SCHEMATIC FOR REFERENCE ELECTRICAL ELECTRICAL 005101111002 010004 PLAN ELECTRICAL DEMO FLOOR LEVEL SECTION FLOOR PLAN PANEL SCHEDULE ONE UNE DIAGRAM SEQUENTIAL DRAWING NUMBER WINN DISCIPLINE AND DESIGNATED CATEGORY Sheet Title PROJECT LOCATION 12100 EAST MARGINAL WAY S. BUILDING OPERATIONS BUILDING BUS ENTRANCE SOUTH BASE COMPONENT SUPPLY AREA WORN AREA PEViS, NS o chances st-;7.1 n=ide to the scope +vc,,rl( ;t pro i approval of Tu'avila et.ii;ciing Division. NOTE: 1-1s,v;s'.-..,ns wiil require a new Wan submittal and m:y inude additional plan review fees. LOCATION MAP FILE COPY terns To srAt F PROJECT SITE DESCRIPTION PARCEL NO:734060-0421 ADDRESS: 12000 EAST MARGINAL WAY 9, TUKWILA WA 98160 LEGAL DESCRPTION: cTAK EN FROM SOUND TRANSIT'S 2004 GUIDEWAY J EASEMENT ON SOUTh BASE) THE NORTH 20 ACRES OF THE FOLLOWING DESCRIBED TRACT: PORTIONS OF THE WEST HALF OF SECTION 10, TOWNSHIP 23 NORTH, RANGE 4 EAST, IN 0100 COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: 22, 23, 24 AND THAT PORTION OF LOT 25 OF BENNETI'S INTERURBAN S, UNRECORDED, LOTS 17, 10, 10, 20, 21 AND UAW) THE RIVERSIDE QUARRY OF RIVERSIDE INTERURBAN TRACTS, ACCORDIN3 TO PLAT RCM IN VOLUME 10 OF PLATS AT PAGE(S) 74 IN KING COUNTY, INGTON; AND RIVER STREET AS VACATED BY SUPERIOR COURT E 110. 063488, ALL LYING SOUTIWVESTERLY OF PRIMARY STATE AY NO. 1, FOSTER INTERCHANGETO SOUTH 116111 STREET, AS 00 67 WARRANTY DEED UNDER KING COUNTY RECORDING NO. AND SUPER13R COURT CAUSE NO. 646846 AND NORTHEASTERLY T MARGINAL WAY SOUTH AS ESTABLISHED BY SUPERIOR COURT E NOS. 646697, 646646 AND 646939 AND THAT P001100 DEEDED TO COUNTY 67 0004 CLAIM DEED. S s i i-LEC1111) FOR. • RC iirMacnanical Eg/Eiectncal 0 Plumbing ErGe.s Piping Ciy of Tukwila BUILD!".1C1 DIVISION A CA 11101 0 CA KIN Perm. 1Lir6/D0) Plan review approva! is subject to errors r:;.i emissions. Approval of construction documents does r1 cut!lorize the violation of any adopted coda or crcEn::.oe. of approved Field Co GENERAL NOTES 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CIT' OF TUKWILA'S CURRENT EDITION OF THE INTERNATIONAL BUILDING CODE AND THE LATEST EDITION OF THE JURISDICTIONAL BUILDING CODE AND AMENDMENTS. A COPY OF THE APPROVED PLAN, MUST BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS, 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL BUILDING UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLBIENTATION OF THIS PLAN. 3. THE CONTRACTOR SHALL TAKEAPPROPRIATE STEPS REQUIRED TO PROTECT EXISTING BUILDING UTILITIES, EQUIPMENT OR BUILT-IN FURNISHNGS REMAINING IN THE WORK AREA DURNG CONSTRUCTION. 4. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO START OF WORK 5. ALL DEMOLITION DEBRIS MUST BE DISPOSED OF LE -GAILY, OFF SITE. PER SECTION 011000 SUMMARY. OMPONENT SUPPLY CENTER DIP TANK REPLACEMENT RECMVED OM VUMILA FEB 08 2018 KING COUNTY P&18 00i BY: Date: '7 2 0088000 City of Tukwila BUILDING DIVISION M.RAPLAN DPANN VALDE2 ePEosEoFONSIATA+rty CrE<KED fle74.31.15Ey J. SMYTH •1 0140000. C. 041176814 P40.10,113 1128164 CONTRACT HO cm-Inc:17 King County Department of Transportation METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT GENERAL VICINITY MAP, LOCATION MAP, SITE MAP AND SHEET LIST Dee MAY 30, 2217 0000010. G0.01 5-0-810: 00 1 16 STRUCTURAL NOTES FOR DIP TANK ANCHORAGE: 1. SEE SHT. M1.01 FOR NEW DIP TANK LAYOUT, 2, BASIS OF DESIGN LAYOUT AND ANCHORAGE PATTERN IS SHOWN FOR REFERENCE ON SHT M7.01. ANY CHANGE TO BASIS OF DESIGN EQUIPMENT SHALL REQUIRE A NEW ANCHORAGE DESIGN AND CALCULATIONS, STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON, TO BE SUBMITTED TO THE PROJECT REPRESENTATIVE FOR REVIEW BY KING COUNTY METRO TRANSIT STRUCTURAL GROUP A MINIMUM OF TWO WEEKS PRIOR TO INSTALLATION . 3. DIP TANK ANCHORAGE TO CONCRETE SHALL UTILIZE HILTI HAS -R304 SS DEGREASED THREADED ROD AT 112° DIAMETER EMBEDDED 6" USING HIT-RE500 V3 EPDXY. (4) ANCHORS MINIMUM. USE STAINLESS STEEL PLATE WASHERS AND STAINLESS STEEL NUTS. ADHERE TO ALL HILTI RECOMMENDED REQUIREMENTS AND PROCEDURES. 4. ALTERNATIVE ANCHORAGE MAY BE SUBMITTED, WITH REQUIRED STRUCTURAL CALCULATIONS STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON, TO THE PROJECT REPRESENTATIVE FOR REVIEW BY KING COUNTY METRO TRANSIT STRUCTURAL GROUP A MINIMUM OF TWO WEEKS PRIOR TO INSTALLATION . 5, EQUIPMENT ANCHORAGE SHALL COMPLY WITH MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. 6, LOCATE SLAB #8 REINFORCEMENT, PRIOR TO POSITIONING ANCHORS AND DRILLING FOR INSTALLATION , TO AVOID CONFLICT WITH SLAB #8 REINFORCEMENT. 7. STRUCTURAL SPECIAL INSPECTION 1S REQUIRED FOR ANCHOR BOLTS. A A No. BY AP A �SYI.Ell _R.0UTTGEN PPPNOWIX D. CFIPPEN REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION RECEEVED FEB 0 8 2018 PEE1v7 CENTER METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT MAY 30, 2017 1128194 C^.�I1RACT OD: King County Department of Transportation STRUCTURAL NOTES CCIIMC17 SVEET 2 16 1 1 neat al** oenter111281 31 EZ://:_.Z. 2 / • - . /7/ /2 / "?. ',/ E!'" /./ ' t ' " / ' '7 ' - ' / ":21(/':" - V/7), r' 4 ( 140 TOOL RM „---- 141 ) TOOL RM 7 /;2a7-221 K/ZZI. 1 i! "`7•1 ----- 142 ) CLEANING R OM I FLAG NOTES I> DEMO EXISTING ALUMPIUM PARTS DIP TANK; SALVAGE SKIMMER AND DIRJVER TO PROJECT REPRESFJITATNE I> DEMO GAS AND AIR PPING T SERVE TANK. BACK TO OCISTIM ISOLATION VALVES 5NOT SHOW RETAIN DUSTING GAB REGULAR:RANO VALVES war sHoWNI. > DEMO DUSTING TANK VENTS AND EXHAUST FAN FOIL BOTH DP TANKS NOT SHOWS; REFER TO PHOTO DETAILS ON MEM. r> PROWCE FLOOR PROTEGTON IN CLEVING ROOM AND PATHWAY BERAEEN ROLL -LP AIM WINS( AREA. DEMOLITION NOTES: 1. CONTRACTOR MUST FIELD VERIFY EXISTING CONCIMON3 PRIOR TO DEMOLR1ON WORK 2 ALL MATERIALS REMOVED DURING CONSTRUCDON SHALL BECOME THE PROPERTY OVINE CONTRACTOR AND DISPOSED OF OFFSITE IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES, AND IN ACCORDANCE WITH CONTRACT DOCUMENTS. 1 EXISTING PIPING ANO DUCTWORK NOT SHOOP/. REFER TO PHOTO DETAILS OPI MO5.01. 4. INSPECT DEMOLISHED DUCTWORK IN COORDINATION VRTH PROJECT REPRESENTATIVE PRIOR TO CLEANING AND DISPOSAL 5. COORDINATE PLAN EON DISPOSAL Cf TANK CONTENTS WITH PROJECT REPRESENTATIVE PRIOR TO COMMENCING DEMOLMON WOFIK 6V ARM DAVE 77171-7777-777 ( •I44_) DISMANTLING AREA ; ,E• i ! 1'; I E t 1 /.! PARTIAL PLAN SCALE: 1/4•=1'.0" 0060,St M. KAMAN .(Th D7CRPFEN OWN V. VALDEZ 006001E(C061,AUVItf -CIftS60 a. ROLA WI 1126164 01111010,41- coEuTZTI Nig County partment of Transportation REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 08 2018 PERMIT CENTER METRO TRANSIT DIVISION COMPONENT RIPPLY CENTER DP TANK REPLACEMENT MECHANICAL DEMOLITION FLOOR PLAN DAIL MAY 30, 2017 mama o0 MD1.01 Per PC 0, 2 16 t' al 0! o DEMO TANK EXHAUST FAN AND DUCT WORK FOR BOTH TANKS DO NOT MODIFY DEMOLISH EXISTING TYPE B VENT TO STACK CONNECTION JOINT INCLUDING BEND STEAM CLEANER STEEL PARTS DIP TANK ALUMINUM PARTS DIP TANK s DEMOLISH TANK GAS AIR AND PIPING TO EXISTING VALVES (NOT SHOWN) RETAIN EXISTING GAS REGULATOR (NOT SHOWN) DEMOLITION NOTES: 1. REFER TO MD1.01. A N REVISION BY D T SECTION SCALE 3/8'=1'-P DEMO EXISTING ALUMINUM PARTS DIP TANK oESIGt PARTS WASHER D CRIPPEN COICRA:1 POI C01177417' King County Department of Transportation REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION OTRECEV ED CIT OF TUKWILA FEB 0 8 2010 PEIRLULLI CENTER METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT MECHANICAL DEMOLTION FLOOR LEVEL SECTION CUT DA MAY30, 2017 MD3.01 NEE7 NJ: 0- 4 4 16 CSC ALUMINUM PARTS DIP TANK REPLACEMENT PHOTO DETAIL SCALE: NONE MD3.01 FLAG NOTES DEMO EXISTING EXHAUST FAN AND TANK EXHAUST DUCTS FOR BOTH DIP TANKS TO STACK CONNECTION JOINTS INCLUDING BEND DLOCATION OF NEW TANK EXHAUST DUCT CONNECTION ALUMINUM PARTS DIP TANK D DEMOLISH EXISTING TYPE B HEATER EXHAUST VENT FOR ALUMINUM PARTS DIP TANK TO STACK CONNECTION JOINT INCLUDING BEND DLOCATION OF NEW TANK EXHAUST DUCT CONNECTION FOR STEEL PARTS DIP TANK DEMOLITION NOTES: 1. REFER TO MD1.01. A Nz REVISION EY DATE CSC TANK EXHAUST REPLACEMENT FOR BOTH STEEL AND ALUMINUM PARTS DIP TANKS PHOTO DETAIL SCALE: NONE MD3.01 A PRO/EO a CRPPEN FROECT 11:8134 CCIlTRACT C01110C17 King County Department of Transportation REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION RECEIVED MIT OF IIISKIMLA FEB 0 8 2018 PERDET T CHE ER METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT MECHANICAL DEMOLITION PHOTO DETAILS 0.41 MAY 30. 2017 DRAWUG IC' MD5.01 NIFE,MO. 6 5 16 ANACAL FLOOR PLAN L ROOR PLAN.dwg Laiml; ; 2 44. g. aORDER dwg; X_MECH •DT.dwg 8 0 5, g 2, go r. /1•!:`1!!!!f.Z ..1 NEW DIP TANK CONSTRUCTION NOTES: 1, CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION WORK I!! ! 2. EXISTING UTILITY PIPING AND DUCTWORK IN ROOM NOT SHOWN FOR CLARITY. REFER TO M3.01 AND REFERENCED DETAILS FOR CONNECTION SCHEMATICS. 3. NEW TANK UTILITY AND EXHAUST CONFIGURATIONS DEPENDENT ON SELECTED MODEL. SUBMIT CONNECTION SCHEMATICS PRIOR TO INSTALLATION. REFER TO M7.01 FOR BASIS OF DESIGN EQUIPMENT. 4. MODIFY EXISTING GRATING AS REQUIRED TO INSTALL NEW TANK 5, CLEAN AREA BELOW AND AROUND NEW TANK LOCATION PRIOR TO INSTALLATION. 6. CLEAN EXISTING STACKS PRIOR TO CONNECTING NEW DUCTWORK. NOTIFY PROJECT REPRESENTATIVE IF A STACK IS OBSTRUCTED AND CORRECT PROBLEM. 7. DIP TANK LAYOUT PER THIS SHEET, REFER TO S0.01 FOR DIP TANK ANCHORAGE NOTES. M5.01 M5.01 4 PARTIAL PLAN SCALE 1/4"=1-0” I I 1 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukvvila BUILDING DIVISION ERECEOVED CM' O ITUMLA FEB 08 2018 PERMY CERTER RES1SIOII APP10 CATE 07. 34! PaC1.ECTP1:1 1128184 C0112RAC210 CA1113C17 King County Department of Transportation METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DP TANK REPLACEMENT MECHANICAL FLOOR PLAN DATE MAY 30, 2017 1000 M1.01 NT. 00 6 '6 P component scpply canter11128184 d;p tankW3.0 sa E STEAM CLEANER / EXISTING STEEL PARTS DIP TANK FLAG NOTES EXISTING TYPE B VENT (NOT INCLUDED IN WORK). INSTALL NEW 10" CPVC TANK EXHAUST DUCTS PER SECTION 233100, CONNECT TO EXISTING CEILING PENETRATIONS. INSTALL NEW TYPE 13 VENT, STEEL TO CPVC TRANSITION FITTINGS, INSTALL TYPE B DOUBLE - WALL FLEX CONNECTOR, MATCH EXISTING IF ADDFI1ONAL ADAPTERS REQUIRED CONSTRUCTION NOTES: 1. REFER TO M1.01. NEW ALUMINIMUM PARTS DIP TANK CONNECT TO EXISTING AIR AND GAS SUPPLY PER 615.01 M5.01 SECTION SCALE: 3/8" = 1 '-0" PARTS WASHER A No. amsloN BY WD DATE CD . KAPLAN DRAWN V. VALDEZ 04ECITDICCOSO1.174111 / CHECKED MUM Ef .7, e....., J. SMYTH ,...) hD. APPROW-D. CaTRACINC1 0J1173C17 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukwila BUILDING DIVISION RECENED CCTV OF 7UKIFIRLA FEB 08 2016 PaRIDLET CERTER King County Department of Transportation METRO TRANSIT DIVISION COMPONENT SUPPLYCENTER DIP TANK REPLACEMENT FLOOR LEVEL SECTIONCUT CATE MAY 30, 2017 NAIVIG M3 01 SH.EI HO a. 7 16 wg I LeyouL' MECHANICAL DE TAILS 5.01 MECHANICAL °ETA ea c 8 0 mm 01,,2 ='o arm 8) <I. o;7. w.. n1pUJ >aK EXISTING 1 1/4' NG PIPE EXISTING 3/4" NG PIPE NEW NG PIPING EQUIPMENT GAS CONNECTION DETAIL SCALE: NTS - DRIP LEG TO EQUIPMENT PER MANUFACTURERS INSTRUCTIONS EXISTING 3/4" AIR SUPPLY EQUIPMENT AIR SUPPLY CONNECTION SCHEMATIC (T1 SCALE: NTS - zr— / TO EQUIPMENT �5 EQUIPMENT SCHEDULE ITEM DIP TANK SKIMMER BASIS OF DESIGN MANUFACTURER MAGNUS ABANAKI MODEL ALHX 7652 6Y752 MECHANICAL TYPE GAS FIRED BELT REACH N/A 24" LENGTH (TOTAL) 110" N/A WIDTH (TOTAL) 90" N/A HEIGHT (TOTAL) 90" N/A CAPACITY 1200 GALLONS 6 GPH ELECTRICAL VOLTAGE 115 115 PHASE 60 60 FLA 20 20 SHIPPING WEIGHT LBS 5600 39 SEE EQUI ENT CIFICATI 235240 FOR ADDITIONAL REQUIREMENTS LEGEND: 0 UNION BALL VALVE FLEX CONNECTOR REDUCER. REGULATOR GAS BALL VALVE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION , RaCENED MIT OF i AINOLA FEB 0 8 2018 PEREirlir. CERITER No. REVISION BY APP'0 ATE REL O.CP1PPEN R.OJECflq 112810.1 rosters.:? COI 17:1C17 King County Department of Transportation METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT • MECHANICAL DETAILS A MAY 30, 2017 Gam: M5.01 TGfl rf B 16 3 a 3 PARTS WASHER ALUMINUM PARTS DIP TANK GLEANS 1G ROOM STEEL PARTS DIP TANK GAS SHUT-OFF VALVE PARTIAL PLAN SCALE 1k•=1'•-0" FLAG NOTES COORDINATE NATURAL GAS SYSTEM SHUT-OFF AND ISOLATION WITH PROJECT REPRESENTATIVE. DO NOT BEGIN WORK WITHOUT CONFIRMING AUTHORIZATION, PER CONTRACT DOCUMENTS. CONSTRUCTION NOTES: 1, REFER TO M1.O1. M 10 FTC 10 2 112"PT 3" METER 5 PSIG 0-300 SCFM 2112" 2" 1 1 STEAM CLEANER 860 MBH NOTE VALVES, REGULATORS, BENDS NOT SHOWN 10 FT DIP TANK 1 530 MBH 2 FT DIP TANK 2 580 MBH GAS PIPING AND CONNECTED EQUIPMENT DIAGRAM SCALE: NTS 30 PARTS WASHER 50 MBH TO 8E REPLACED IN KIND REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 8 2018 PERMIT CENTER METRO TRANSIT DIVISION CCMPONENTSUPPLY CENTER DIP TANK REPL.CEMENT COMIACTvtx is King County Department of Transportation y COMM NATURAL GAS SYSTEM MEET M0: 6 9 16 5 0 0 0 in - a 0 0 5 z 6 0. 0 1.75 24.22 78.38 1.75 1 .50 TOP VIEW 29.88 24.22 NOTE: DIMENSIONS ARE IN INCHES, REVISION BY FORK CHANNELS FRONT VIEW OATE 68 38 71 38 4.00 * NOTE: TYP. (4) FRAME IS A WELDMENT AND NOT A MACHINED PART. HOLE LOCATIONS CAN VARY AS MUCH AS .25" iErnensTons In [ ] Are iffraetera. Tolerance (unlese Stated °harem): ± .04 In,± 1 mm. Bend Radii Orden Stated Others-mut:6 In, 1.6 mm. - Break MI Comm. Remora Stara Md Barra. REVISIONS 'ME CONTEK OF THIS MATERIAL IS F1TCPRIETAFEr AND CONSIITURZ A TRADE SCREE THIS LS NOT A PUBLICATION. RS FURTHER DISCLOSURE IN AM' FORM WITHOUT BRITTEN PERMISSION OF ITS OWNER, MANUS EQUIPMENT, 10 PROHIBI1ED. IT IS TO BE RE116INED TO RS MINER UPON REQUEST.' 1»"TN`#6 ALXH BASE WELDMENT (PART OF TANK WELDMENT) STANDARD ors'" R.P.T. Dcrt' 12-01-20I5 Scats 1:24 #6 ALXH 1:/RPI PART No. CUSTOMORAWII4G NO. t PROJECTria. 1128184 CONIR,ctril C01173C17 44...yor 0jro,..12 1.,F-1.1 TON U80 tHoto$ -axer." MACHINE DIMENSIONS :^.- MACHINE NUMBER: , V4 L#5 . INSJDE-T8ANK.. , Length 5,.00" 5100" 78.00" I Width B 4',$.00" 5..00" 68.00" Depth C 4i.00" 4;?.00" 60.00" 0.131M4d SFACP : - - -" " ' --r Length 0 5,.00" 0.00" 76.00" Width . E :.00" 15..00" 52.00" Depth (See Note 2) i 2;5.00' 1, 2,?.00" 44.00" Ciifi:i01-1..74Aijkiiiii9iV: Length 6 .00" 7).00" /12.00" Width H 450' 51)k.50" 70.50" ight t, 4525' 4, 4,) 25" f * 4. 5" .dititAujuiatiiitit4--- - - Length (gas K 7:?25 8)..25" r 110.50- 3/4Art —..'• n* e.... on tw, ------- r ..6-..4.1hat'Am __.:_...... ___..• Width L 8150" 5.,).50" 90.00" Height ,225" " ' 91-.it.25 128.00' _:ACILLET ROIATFDRiti- _,. Total Lerigth 0 51.00" &L00" 75.00" Roller Width E 2T.50 450" 49.50" •:104.00010.04-:-:!-- - ' ' :- . . _ - _ — - :: ---,* ,: -; Height (above tank bottom) N 3,..00. 3il.00" 52.00" REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukwila BUILDING DIVISION King County Department of Transportation RECEOVEED CM OF TUKWILA FEB 08 2016 PERLET CENirati METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT BASIS OF DESIGN INSTALLATION SCHEMATIC FOR REFERENCE 1142E MAY30, 2017 OrAYA0210 M7.01 saarn 10 16 PANEL P5 icy!! 17,) IA! ;;;;;;A t/J: VA ( 140 TOOL RM '0 12;1 Kl 1;1 I f V 4 I CA '71,,, , •;,-7 7.7:7-z,,-. ,r , .,--'- --77,7- . 1 Iii 1, . I I 142 CLEANING ROOM f 1 9 ) !:,-(7-72.L27:-!!!..?f,! DISMANTLING AREA PARTIAL PLAN (Th SCALE 1 /4•=1' -13 - GENERAL NOTES 1, CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS PRIOR TO DEMOUTIDN VI( 2 ALL MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFFSITE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES AND CONTRACT DOCUMENTS.. 3. UGHTING AND STEEL PARTS DIP TAM( noku. BE OPERATIONAL THROUGH OUT TM CONSTRUCTION, FLAG NOTES REMOVE ALL EXITING WIRING ASSOCIATED WITH BOTH DIP TANKS, RECEPTACLES AND EXHAUST FAN REMOVE EXHAUST FAN AND THE SECTION OF THE CONDUIT ASSOCIATED WITH THE EXHAUST FAN. AWMNIM TANK mantel SHALL BE SALVAGED AND DGJVERED TO PROJECT REPRESENTATIVE. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukwila BUILDING DIVISION 7 King County Department of Transportation C11117X17 RECEIVED CITY OF TUKWILA FEB 08 2018 PERMIT CENTER METRO 'TRANSIT DIVISION COMPONENT SUPPLY CENTER DP TANK REPLACEMENT ELECTRICAL DEMOLITION FLOOR PLAN OF 11 16 ELECTRICAL WIRE REMOVAL DEMO (--Th 1 SCALE: NTS ELECTRICAL SKIMMER DEMO /P -3 -- SCALE: NTS - --.ne ND. REVISION BY APP.D CATE ELECTRICAL WIRE REMOVAL DEMO SCALE: NTS ELECTRICAL SKIMMER REMOVAL DEMO ( SCALE: NTS DEsrAED S. ANDD MAWR .MAKABLE CH_`kED(CONSULTARTI CHECKED IvroocseNa R. REYNOLDS rrpamED D. GRIPPER PROJECT/} 11241&4 CONINM:I10 1 001113317 c_ King County Department of Transportation FLAG NOTES 1. SEE DRAWING ED1.01 FOR FLAG NOTES: REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION RECEIVED CRT OF TUKWILA FEB 0 8 2018 PERMIC CEDEFER U ER METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT ELECTRICAL DEMO DATE MAY 30, 2017 SPAn61o: ED1.02 12 16 r; EXISTING STEEL PARTS DIP TANK NEW ALUMINIMUM PARTS DIP TANK s 2 1 1 P SECTION SCALE 3/B"..1'-0' A FLAG NOTES IISTALL.NEN WIRING FOR BOTH DIP TANKS AND RECEPTACLES. AU. WIRING SHALL BE 12AWG THMYTIfIN UNLESS OTHERWISE STATED. INSTALL A NEW 120V DUEL GFCI PROTECTED RECPTACLES. ALL RECEPTACLES HALL BE 120V AND HAVE GFG PROTECTION. THE RECEPTACLES SHALL BE FLUSH MOUNTED 4TABOVE FINISH FLOOR. TIMER SWILL BE ELECTROMECHANICAL 120VAC, 20A UMMNM WITH 24-HOUR TWE SETTING. TIMER CDNTROS ALL RECEPTACLES THAT FEED THE OIL SIOMMERS *NBTALL TWO DISCOWIECzSWITCHES. DISCONNECT SNITCHES lictilDE FORD 30A 1P, 120VAC. NEMA 3R RATED. P 1 3 2018 ~ CRY OF TUKWILA FEB 13 2018 City of Tukwila BUILDING DIVISION 00 FEB 0 8 2018 PERMIT CENTER BETTI r vsrr DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT DATE MAY 30, 2017 King County Department of Transportation FLOOR LEVEL SECTION E3.01 5 A_ PANEL PE -L PANEL PE -R PANEL P5 ,'"--- . / , ,.. .. PANEL LB 1 CI- F AC P i ; 1 11:!):77.7,"/77:27Z/1:777.: -772777)77//77-1y i ? •-: r/i / i I - ( i. . ; „„...-,--47-:;;... , ....„. : !..,,i"' .! TOOL RNA '4 I Vi k. 142 r 1 V ( Li i i li .... .0 / ./1 22.27 77772777 22.---7 I / ( 141 TOOLRikill B I I CLEAN IN G' ROOM I vi 1/i la/1 if) . , 1,1 1.11 VI 7 vi r .. ..,4 ••„..........._,iIA . If r 144 ,,, DISMANTLING AREA /1 •_e_V " BY APPD RTE PARTIAL PLAN SCALE: 1/41'Mr S. A1400 0. 1611FtAIILE C16121101COMULWOr. c 11CPIPPEO1 GOIITSIT KingCounty Department of Transporration FLAG NOTES 1. SEE DRAWING E3.01 FOR FLAG NOTES: REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKVVILA FEB 08 2018 PEWIT CENTER METRO TRANSIT DMSION COMPONENT SUPPLY CENTER DP TANK REPL4CEMENT FLOOR PLAN DAM MAY 3D, 2017 E3.02 VIIFF7 14 16 oul: EB 01 PANEL SCHEDULE mponent supply center11128184 dip lank.E6.01 PANEL SHEDULE.d LLLG I I/GAL PANLL SGI1tUULt PANEL P5 BLDG CSC BASE S3 DATE 12113y.17 IPE SQ. D NQOB (QBM 43635) LOCA.TICN UNIT REBUILD CORRIDOR, Cad E.16 SLRFACE or RUSH' MAIN BKR ROW SURFACE 100 AMPS 100A, 208Y!1200, 3PH, 4W REF. DL'IG. 9O REVLSINLD EI0IEER (206-253.713) FEEDERS (OM, (I) 18 GND,1414"C FROM PNLPE, EXT 24,VIA30KVAMIR TS SHERTOST.Ra, Isyai 055VI2OCJ(T. - DM1EREVISEO SEPT 2402 JOB NO. rb. RD/13113V DA Muse :1 Lind 0. CRIPFEN PROJECT 0011T3:17 King County Department of Transportation FLAG NOTES CIRCUITTO BE MARKED SPARE AND TURNED OFF AFTER THE SLOWER IS REMOVED. CONTRACTOR SHALL UPDATE AND POST EXISTING PANEL SCHEDULE. BREAKER TO BE TURNED OFF, TAGGED AND LOCKED OUT BEFORE REMOVAL AND REPLACEMENT OF CONDUCTORS. CIRCUITS SHALL BE PUT BACK INTO SERVICE AT COMPLETION OF THIS JOB. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION WG CEOVUO ©0` f O 7 l Gaff ilLA FEB 0 8 2018 PEh11EU U CER ll ELN METRO TRANSIT DIVISION' COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT PANEL SCHEDULE MAY 30.2017 IA: E6.0 1 15 16 FWMES t'FE AVPERACE CROW & AMPS 5E LOAD DESORPTION 15 a b c LOCATOR 1a 209115 012 (2) PEEP 3.0 UNfTREHULD 39 2SS/ IP 412 (1) FLOOR RECD (1) RECP 3.0 09115E92 0 5c X41 IP 012. f3) FEU' 4.b 19111/ BULO 7a 20>ti1? 042 (3)Baal RECP 9.0 ON16IEBULD 99 20914? 012 BE R. 9.0 L44WEB 11C 209/15 412 SPARETOBOX-DS IPNR.EAREA 13a 209(15 912 SPARET080X-aSMANREAREA 155 15A11P 412 SPARE TOBOX •DEEIWANTEA1EA 17c 209/P 412 /3)RECP 4.5 MLLWRIGNT 19a 20A/15 412 (3)RET 4.5 401.10/51041, RAIL 21b 209/15 512 (1)ECP 15 HAIL 23c ISAI15 k12 (EL) 116350140105 114 42 ROOF, COL. X16 25a 214 / 1P 410 REP 14a DISCON'xCT 6.25,1,11212 4E0 6E REBULD, CO(_ G14 27b 304 / P 410 (2)ECF, 064115, r. tMEER, LIGHT 11(1,113 6.7 IE REBULQ COL D-14 29 249/45 412 {3)RE(F 45 TPANSh45SIONSKOF 310 24/15 412 P 339 2btliP 112 TZ}1 3.0 iROISNlSSIOSSNOP 35; 209115 412 (2)775 4.5 TRA 45051 2a 20AI1P 412 (1)R00RRECP 1.5 I Kr FEUD 45 MA/ IP 412 RI 2) BEIM FED, 10 MTRFSIND " 6c 24AIiP 412{c1} {IkICCEPTACLESYrASTEOILPUMP 11,6 C1fAI8NGD1Si4ANTlf 209!15 012 5I1 t;a0 t1SG1, a)1 C( 15.4 CLEAIYiG A 1Tb 29115 412 STUBPI#OPCONSOLE 100 ENG6Ei Uii}SE 12c 150 / 11' 012 (6L} IS 350 5.0 HA Ci OISIAANREIUi 14a 209115 412 DUCTBIOVER 5.0 CLEANING RM 169 205 / 15 612 (DEEP 6,0 SANDBLAST,'HA 18c 20AIIP 612 (5) RE 140 MacOMae /Reb4dOff ce 20a 205i0P 612 (DEEP 1.5 01.11Su0ETOLR 225 154 / 1P 412 AC3 112,1/4 14.3 WARM' °FEE 24c 213A11P 012(Ik) LUGH8%CONIREL 0S RAIL 26z 20AtiP (2)412 ALUMINUM LEAATI4GTANK 16.0 215501 IGRM 216 ) 1 10.0 30c 20511P 012 STEEL Q fANBIG TA IK 109 C150004G RM Sia 3DA11 12 01) (i}Kg 3.0 TPANSKIS SKIMSKY 340 300111' 412 (3)RECP 10.0 IRANSDYNO 36c 20011P 412 (3)55CP 4,5 1RAts5MSSI01ISHOP DEMAND WA= 2E2 00514561000114' 2E2 75.0 76,4 67.2 00595 AMPS rb. RD/13113V DA Muse :1 Lind 0. CRIPFEN PROJECT 0011T3:17 King County Department of Transportation FLAG NOTES CIRCUITTO BE MARKED SPARE AND TURNED OFF AFTER THE SLOWER IS REMOVED. CONTRACTOR SHALL UPDATE AND POST EXISTING PANEL SCHEDULE. BREAKER TO BE TURNED OFF, TAGGED AND LOCKED OUT BEFORE REMOVAL AND REPLACEMENT OF CONDUCTORS. CIRCUITS SHALL BE PUT BACK INTO SERVICE AT COMPLETION OF THIS JOB. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2018 City of Tukwila BUILDING DIVISION WG CEOVUO ©0` f O 7 l Gaff ilLA FEB 0 8 2018 PEh11EU U CER ll ELN METRO TRANSIT DIVISION' COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT PANEL SCHEDULE MAY 30.2017 IA: E6.0 1 15 16 1 Layout ONE LINE DIAGRAM dip lanME6.02 ONE LINE DI Iles \ somponent supply TO PANEL "0" WoKTENANCE BU WI NC - -1 00A/ 3m A .Z1.8 30KVA 480-48CY/ 277V 6101A C, 3/4'C TO MAIN DISTRIBUTION SWITCHROARD MAINTENANCE BUILDING 51-V-502 0 / / 5 I - I) -503 / 1.7 j / 6005, 30 1 1 i r - - - I _ _I SWITCH, 1.8 KV LOA0 INTERRUPTER I I. 1 I 1-Y-4-02 250 E XXX? (3) 2.,5/5K5 CURRENT UMiTING POWER FUSES 750 KVA 4160, 480Y/2775 2 = 5.3% TRANSFORMER 0 ) 9 on—,000A17,200/1. SUBSTATION (MEZ ZAN IN E) PANEL PDA 1200A BUS, 480/277V, 36, 4W 0 2254 4005 SUB FEED LUG I7A 1505 17 200A 505 705 7607 ) 3005 1111405, (TIE )--y CFI B881.71.64)61 N.C. • 0 I11 12 \ 51-Y-403 TO OiSTRIBUITON F,UOSTArioN 1.1/1.1/108014EI/W:6H BOLDING 1 0, 0/ 51-U-505 GOOA, 35 LOAD INTERRUPTER I SWITCH, aM KV 51-Y-404 250 E X8080(3) 2.5/5K5 CURRENT LIMITING POWER TUSFS 750 K54 4150, .180Y/277VSOV/2775 Z = 5.3% 7RAN3 FORMER 0 - PAINT/ DRYER CONTROL pANEL #1 PANEL. PI 30KVA '14 L.L.1. 0 48-205/ 1205 rrn 101 t 04511 158 .732 30KVA I1 480-208 /120V 22 rrrn *Kw. 450-208 /120V n 30I<V5 480-208 /1205 PAP5961 4/.13 454561 01818 450 281861 P2 46800 SW 412 Da 105 PANEL 08 P12 PAWL 280 1/0 008141004 GM PI/ L6 WJJ 9., REM ON BY DATE PAJIEL PR2A, 00 FCF FCP 71 --15055 480-205 /1205 9 FURNACE FJRNACE GAG 8:41 T/0 456/5 480-208 /120V 011-10005T/1200AF FLAG NOTE INDICATING NEW CIRCUITS AND BREAKERS SUF3SIATION "B" (LOADING DOCK) PANEL PDE3 1200A BUS. 480/277V, 3s, LW 1755 I/70 o 75,4 125A 1504 50A 1! 12 13 114 15 0 610? 408 MO$H8ii F—jP P1-15, I -1M, P590, 8 COL. E16 COMP C01,0 CA -2 CA -1 .1D 30WA 450-208 I 1 I I /120/ 101,1 RCS MACHINE 4405 10 L A U-1)15 IrT40 06V-5208 240 /1205 II 11480-2 /1205 1005 R 110 PHOTOCELL ON ROOF TO 60HP MILUNG MACHINE 5ePiovED: 0.0015208 PROJECNO, 1128184 6081400 440 00111301? !,2 3, .80 1U.WI8 =75KVA15KVA 480_208+, I I I 1480-20R /1205 /1205 4-12, 400 1-1/4"C LPiNa. PARTS 11 1 14 Poyi. 304 8083 187 King County Department of Transportation 0 PWNT soarri nsFArmiNc. AIR comP iT G. I'M 1. XP vAr - 50A/3P 60AF 1505 400A SLIEFEED 9 LUG CCP PANEL P44 4404 mut' 14 187 ELEVATOR CONTRO VIA 70 53680 Ea -1305 1 HAZARDOUS MATERIAL 51 -IED ,058 4864 68346816 SHED REVIEWED FO CODE,COMPLIAN APPROVED FE3 1 3 2018 0760 4iINA 4A;Ci -Tukwila BUILDING DIVISION ECMVE© C02.00 08 157 I OF ILDKOLA -FEB 08 2018 PC m- CERSTER METRO TRANSIT DIVISION COMPONENT SUPPLY CENTER DIP TANK REPLACEMENT ONE LINE DIAGRAM 11. MAY30,2017 0065144,10 E6,02 1.4 16 15 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0014 DATE: 02/08/18 PROJECT NAME: KING COUNTY METRO SITE ADDRESS: 12100 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Pt -J WI Building Division \i(/ NPr /146 Public Works Fire Prevention Structural Planning Division Permit Coordinator ri PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 02/13/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n DUE DATE: 03/13/18 Approved with Conditions n Fl Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 NORDIC CONSTRUCTION INC Hoene Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 3 A -Z Index Help M''L&I Workplace Rights Trades & Licensing NORDIC CONSTRUCTION INC Owner or tradesperson Principals ERICKSEN, MARTIN J, PRESIDENT MILLER, JOHN T, VICE PRESIDENT ERICKSEN, GORDON J, SECRETARY MINNEMAN, ANDREA M, TREASURER ERICKSEN, LAURICE J (End: 01/01/1980) ENLOE, ERIN M, VICE PRESIDENT (End: 05/23/2001) Doing business as NORDIC CONSTRUCTION INC WA UBI No. 601 164 241 106 55TH AVE E FIFE, WA 98424.2426 253-922-3100 PIERCE County Business type Corporation Governing persons MARTIN J ERICKSEN GORDON J ERICKSEN; JACK MILLER; JOHN T MILLER; ANDREA MINNEMAN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ............................ Meets current requirements. License specialties GENERAL License no. NORDICI110LZ Effective — expiration 06/0911989— 03/22/2020 Bond BERKLEY INSURANCE COMPANY Bond account no. 0138520 $12,000.00 Received by L&I Effective date 03/03/2014 03/22/2014 Expiration date Until Canceled Bond history Insurance ................. Everest Indemnity Ins Co $1,000,000.00 oR`j `f -co Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601164241 &LIC=NORDICI11 OLZ&SAW= 2/14/2018