Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG18-0015 - LANTERN LANDING (SHELL) - INSTALL NATURAL GAS PIPING FOR (5) PACKAGE ROOFTOP UNITS
LANTERN LANDING 1233 ANDOVER PARK E PGI8-0015 Parcel No: Address: l City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 3523049084 Permit Number: PG18-0015 1233 ANDOVER PARK E Project Name: LANTERN LANDING (SHELL) Issue Date: 5/22/2018 Permit Expires On: 11/18/2018 Owner: Name: PETERSON MATT Address: 3356 E SHORE DR HOUGHTON HARBOR LLC, SEATTLE, WA, 98112 Contact Person: Name: HEATH HAMBLEN Address: 4102 B PLACE NW , AUBURN, WA, 98001 Contractor: Name: UNIVERSAL REFRIGERATION INC (CONST) Address: PO BOX 614 , AUBURN, WA, 98071- 0614 License No: Lender: Name: Address: UNIVERI159RF Phone: (253) 939-5501 Phone: (253) 939-5501 Expiration Date: 4/1/2020 DESCRIPTION OF WORK: INSTALL NATURAL GAS PIPING FOR (5) PACKAGE ROOFTOP UNITS Valuation of Work: $1,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $129.28 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized SignatureVA/ : / / I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: \-.) Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING r� 9001 UNDERGROUND \.J CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. Date Application Accepted: Date Application Expires: or of ce use on PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 3,5Z_3O`7tc7O�� Suite Number: Floor: New Tenant: ❑ Yes ..No Tenant Name: e4/4A. PROPERTY OWNER Name: Heath Hamblen Name: pe_ f -e Phone: (253) 939-5501 Fax: (253) 735-3432 Email: heath@universalrefrig.com /` 00 i frt./ 1. Address: (4 /' -. i� © re-P� City: / v State: 14 Zip: w311.2 CONTACT PERSON — person receiving all project communication Name: Heath Hamblen Address: 4102 B Place NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email: heath@universalrefrig.com 1111111111111. PLUMBING CONTRACTOR INFORMATION Company Name: Universal Refrigeration Address: 4102 B Place NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 939-5501 Contr Reg No.: UNNERI 159RF Exp Date: 04/01/20 Id Tukwila Business License No.: BUS -0993124 Valuation of Project (contractor's bid price): $ /06-�` Q* � f eC 4 cc --4 ! c ft t Scope of Work (please provide detailed information): / 5741, l/ . f ey 5 c) r„ S` / (;-) c roc t LA -11,` 1 ! Building Use (per Intl Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: H:ApplicationsWosms-Applications On Line 12011 Applications\Plumbing Permit Application Revised 8-94 l.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not inctuded m lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain ' Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated- Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THATI HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: /� Print Name: A ,0 C.(1 Mailing Address: 4102 B Place NW H:1ApplicationsWonns-Applications On Line:2011 Applications\Plumbing Permit Application Revised 8-9-11.doc, Revised: Augusi 2011 bh Date: 2/) 2.// � Day Telephone: (253) 939-5501 Auburn WA 98001 City State Zip Page 2 of 2 7 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $129.28 PG18-0015 Address: 1233 ANDOVER PARK E Apn: 3523049084 $129.28 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13768 R000.322.900.04.00 0.00 $4.97 129.28 Date Paid: Monday, February 12, 2018 Paid By: UNIVERSAL REFRIGERATION Pay Method: CHECK 53031 Printed: Monday, February 12, 2018 2:59 PM 1 of 1 (?") t'001tc INSPECTION RECORD... Retain a copy with perm INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 14:W7r/eV MN Type of Inspection: oAsfee Address: /233 4vciaree Date Called. Special Instructions: *5 PT e-Ameir, Date anted: a.m. . - 200 p.m. Requester: 'Pre -4e- C -Ce /41? 19 vni-e-PC Phone No: i - 206, - 96 - 77/9 Approved per applicable codes. Corrections required prior to approval. COMMENTS: S1 -e A tkC r P 143- ys6,.90 2p51 Fe RTU cg z)( 6.43 P 7 LS 2-0 -04 & II -5 o,ffS of •Itz.-( 6Al-Ak Oueld ATr/b—at Date: 2-0‘2-6.1fc REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedute reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 44/11177/a/ 1.1910/1)6— Type of Inspection: R0064HN 09,6* Address: 1 33 ffna:)$//CR PARK E Date Date Called: Special Instructions: Date Wanted: bib — P.m. Requester: TED Phone No: 2.04' — 3942- -79/9 Approved per applicable codes. EjCorrections required prior to approval. COMMENTS: R4>te--//--/A/421-3- i/4' Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SEISMIC ROOF CURB ATTACHMENT DETAIL \, NEOPRENE GASKET NOTES: 1. ATTACH BRACKET TO INSIDE TOP OF CURB USING TEK SCREWS SUPPUED AS SHOWN, ATTACH MOUNTING BRACKET TO CURB BEFORE MOUNTING BEFORE MOUNTING UNIT ON CURB. 2. AFTER SETTING UNIT ON CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL ON UNIT WITH TEK SCREWS SUPPLIED AS SHOWN. 3. A QUANTITY OF FOUR (4) SEISMIC BRACKETS PER ROOFTOP PACKAGE UNIT. 4. ONE SEISMIC BRACKET IS TO BE INSTALLED ON EACH CORNER OF THE ROOFTOP PACKAGE UNIT. WOOD NAILER SECURE BRACKET TO CURB WITH (4) #10 SCREWS 18 GA. RESTRAINT BRACKET FACTORY CURB GAS PIPING REGULATOR DETAIL 00 LI 0 0 ..J n n 409.4 MP REGULATOR VALVES A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR 02 409.5 APPLIANCE SHUTOFF VALVE EACH APPLIANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1, 409.5.0, OR 409.5.3 ® VENT LIMITERS ARE DESIGNED FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE I5 CRITICAL. VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN VENT PROTECTION IS REWIRED. ® 411.1.6 UNIONS A UNION FITTING SHALL BE PROVIDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN 6 FEET (1829 MM) Of THE APPLIANCE. ® 410.1 PRESSURE REGULATORS A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE ATA LOWER PRESSURE THAN THE SUPPLY PRESSURE. UNE PRESSURE GAS REGULATORS SHALL BE USTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUDOOR INSTALLATION. ® A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. n A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE -MEASURING INSTRUMENT. FILE COPY Permit M .#®\)(9l 2- 0M5 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted cods or ordinance. Receipt of approved Field Copy . • nd"ons i )' • wiedged: B Dat City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work withc°:r prior approval of TtU!c4J1ia Bu:)7y(Tno Division. INOTE: RoV ;,;7 ,s will req Lire n and may ir,y,ud0 P ct^'s,anew plan submittal�nal plan review fees I SE fl �E r i lL,r�IT CI'.ally.";) FOR: C ' 3chanical C�3'6!ectrical I Plumbing 0 Gas Piping C: ,F of Tukwila 61,41(,6" DIVISION PACKAGE ROOF -TOP UNIT EQUIPMENT SCHEDULE ID BRAND NAME MODEL NUMBER AREA OF SERVICE CFM SMOKE DETECTOR S.P. GAS HEATING NET COOLING CAPACITY (BNh) SEER EER IEER EFFICIENCY OR COP V/PH MCA MOCP SOUND RATING WEIGHT T INPUT (Btuh) OUTPUT (Btuh) RTU -1,2,3 CARRIER 481000089246 OFFICE 3,000 YES .5' 125,000 103,000 90,100 • 11.0 12.8 82% 460/3/60 20 25 82 SONES 1,087 LBS RTU -4,5 CARRIER 48KCDA06A2A6 OFFICE 2,000 YES .5' 72,000 59,000 61,840 14.10 - 82% 460/3/60 14 20 77 SONES 772 LBS *UNIT INCLUDES FACTORY ECONOMIZER CAPABLE OF 100% OSA **HVAC SYSTEM DESIGNED & ECONOMIZER CONTROLS SHALL BE SUCH THAT ECONOMIZER OPERATIONS DOES NOT INCREASE THE BUILDING HEATING ENERGY USE DURING NORMAL OPERATION (WSEC 2015-C403.3.2) LNOTE: These plans are diagrammatical only. Please verify all dimensions at job site. HVAC ABBREVIATIONS AFF ABOVE FINISHED FLOOR 800 BACKDRAFT DAMPER BTUH BRITISH THERMAL UNIT PER HOUR CD CEILING DIFFUSER CFM CUBE FEET PER MINUTE CU CONDENSING UNIT DB DECIBEL 011 DUCT HEATER DOAS DEDICATED OUTSIDE AIR SYSTEM DN DOWN EC EVAPORATOR COIL EER ENERGY ERTCIENCY RATIO EF EXHAUST FAN EG EXHAUSTGRILLE ERV ENERGY RECOVERY VENTILATOR ESP EXTERNAL STATIC PRESSURE EXH EXHAUST FCU FAN COIL UNIT FD FIRE DAMPER, FLOOR DRAIN FPM FEET PER MINUTE FSD PRE AND SMOKE DAMPER GA GAUGE GF GAS FURNACE GRD GRILLE, REGISTER, DIFFUSER HP HORSEPOWER, HEAT PUMP ID INSIDE DIMENSION THP INDOOR (SECTION) HEAT PUMP TRH INFRARED HEATER KW KILOWATT MBH THOUSAND BTU PER HOUR MCD MOTORIZED CONTROL DAMPER NC NOISE CRITERIA NIC NOT IN CONTRACT NTS NOT TO SCALE OLID OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIMENSION OR DIAMETER OHP OUTDOOR HEAT PUMP OSA OUTSIDE AIR OSCI OWNER SUPPUED CONTRACTOR NSTALLED POC POINT OF CONNECTION RA RETURN AIR RAG RETURN AIR GRILLE RPM REVOLUTIONS PER MINUTE RIO ROOFTOP UNIT SA SUPPLY /AR SG SUPPLY GRILLE SP STATIC PRESSURE SSG SIDEWALL SUPPLY GRLLE TBD TO BE DETERMINED TG TRANSFER GRILLE TYP TYPICAL UH UNIT HEATER VFD VARIABLE FREQUENCY DRIVE VTR VENT TO ROOF WI' VARIABLE VOLUME AND TEMPERATURE HVAC LEGEND lV ❑ INLINE EXHAUST FAN(S) O ROOFTOP EXHAUST FAN IJ SIDEWALL EXHAUST FAN VAV FAN BOX I7 CEILING EXHAUST FAN 0 GAS METER ZD12 WT DAMPER —Q THERMOSTAT X T -BAR SUPPLY DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER HARDLID RETURN GRILLE FD .— FIRE DAMPER FSD 4 - FIRE SMOKE DAMPER VOLUME DAMPER SD �- SMOKE DETECTOR FLEXIBLE DUCT SARA ROUND DUCT UP ROUND DUCT DOWN DIFFUSER TAG R =VIEWED FOR CODE COMPLIANCE APPROV[_C FEB 14 2010 City of Mimila BUILDING C HVAC NOTES 1. DUCT INSULATION TO MEET THE REQUIREMENTS OF SECT- ION C4032.8 OF THE 2015 WSEC AND SECTION 604 OF THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR DUCTS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE DUCT DETECTORS SHALL SHUT DOWN POWER TO THE UNIT UPON ACTIVATION AND A SUPERVISORY' ZONE SHALL BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT DETECTOR ACTIVATION. IMC SECTION 6062.1. 3. DUCTWORK-IANNTRUNK IS 11-42 IN CONDITIONED SPACES AND 0A W UNCONDITIONED SPACES AS PER THE WS80. 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURERS INSTALLATION INSTRUCTIONS PER I.M.C. 2015, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S.E.C. 2015, SECTION 0403.3.1. 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE FOR INSPECTIONS. 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. 7. DUCTS TO 8E SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12'-0' MAX., HORIZONTAL AT 10-0' MAX. WITH STRAP, OR 8'-0' MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF C408 WSEC HAVE BEEN SATISRED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0&M MANUALS, SYSTEM BALANCE REPORT, AND A COMMIS- SIONING REPORT. 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 0403.2.8. DUCT WORK WHICH IS DESIGNATED TO OPERATE AT PRESSURES ABOVE 1/2' WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 NCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS W ROUND AND RAT OVAL DUCT WORK DO NOT REQUIRE SEALING: HOWEVER, OTHER SEAMS SHALL BE SEALED. 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT WALL PENETRATIONS. 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS WELL AS VENTILATION REQUIREMENTS (AS PER TABLE 403.3.1.1, 2015 IMC MINIMUM VENTILATION RATES) AND OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE 11ME OF THE TENANT IMPROVEMENT PERMIT. SCOPE OF WORK JOB# 17260 1. INSTALL (5) ROOFTOP PACKAGE UNITS. 2. INSTALL NATURAL GAS PIPING. Racamo CGTV OF TttW L1 FEB 12 2018 RERUN CERTER P618- tho is PENDING CITY APPROVAL • G EFECE2L TIG - AIR CON3108 NG • HEAT PUMPS • REFRIGERATION - CONTRACTORS UN NSE 1016E0 AUBURN: (253)930-5501 TACOMA: SEATTLE: (259) 5352125 5AK UMBER)15987 (253) 822-3141 (253) 735-3432 P.O. BOX 614 -AUBURN. WASHINGTON 93071 (3)(( R5K RETAMFRATgN OMW WG.289 REVISION DESCRIPTION PERMIT ISSUE m 0 O lU J F 1- 0 W 0 O 0 PRINT/PLOT DATE: 01/10/18 DRAFTER: ARW DESIGNER: HH PROJECT MANAGER: HH JOB NUMBER: 17260 SHEET NUMBER: M -C 238 CFH @100'QM (3) LOW PRESSURE 119 CFH @ 100' NAT. GAS METERS 138 CFH @100' 3/4' 4' 3!4' 3/4' �1—, ( 1170.1 ) 119CFH @100' 4 I g_J 119CFH @100 RTU 2 ) 3/ 3/4' r RTU -3 ) J 119CFH @100' - J 69CFH@100' ( RTW ) • 1 (RTU -5 ) 69 CF11@100 =,.2 L! 11° DN ut(-c 7 REVIEWED FOR E CODE COMPLIANCE;1 AYIRO f FEB 14 204 City of Tukwila,' lila BUILDING DIVISION RECEOVEOn CRT OF TUKIZLQ FEB 12 2018 E DEER �NL©E T QHVAC OFFICE PLAN NOTE: These plans are diagrammatical ony. Please verity all dimensions at job site. PENDING CITY APPROVAL • MVLT SEMLn1RICA !AM( CONDITIONING • HEAT RUMPS- REFFIIGERAIION! CONTRACTORS LICENSE NUMBER: UNNERI 15911E AUBURN: (253)(09.5 OI TACOMA (253)822-3141 5433132 253) B3S2125 544: (253)7353432 P.O. BOX 614 • AUBURN, WASHINGTON 68671 trvt6tEERIOERATIONINEAWArmEO0 ISION DESCRIPTION CC 0 0 SZ 0 w J r- 0 w 2 0 O 0. 0 z� Q Y J zw O CC < W w 1 O z° Q Qco co co PRINT/PLOT DATE: 01110/18 DRAFTER: ARW DESIGNER: HH PROJECT MANAGER: HH JOB NUMBER: 17260 SHEET NUMBER: • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0015 DATE: 02/12/18 PROJECT NAME: LANTERN LANDING (SHELL) SITE ADDRESS: 1233 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A -T iftuc Building Division Public Works P Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/13/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 03/13/18 411. Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping PW Staff Initials: 12/18/2013 UNIVERSAL REFRIGERATION hington State Department of abor & Industries I I ome Espanol Contact Safety & Health Claims & Insurance Page 1 of 2 Search L&I AZ index 1:Ielp My L'Sii -$%, 2: 1 Workplace Rights Trades & Licensing UNIVERSAL REFRIGERATION INC Owner or tradesperson Principals GATES, CHRISTOPHER A, PRESIDENT GALVIN, BRYAN S, VICE PRESIDENT GATES, CHRIS A, AGENT VERNON, GUY E (End: 01/01/1980) JACKSON, SHELDON G (End: 01/01/1980) OSENBAUGH, CHARLES R (End: 01/01/1980) RAEDER, STEVEN C, PRESIDENT (End: 03/29/2012) Doing business as UNIVERSAL REFRIGERATION INC WA UB I No. 600 599 723 PO BOX 614 AUBURN, WA 98071-0614 253-939-5501 KING County Business type Corporation Governing persons BRYAN GALVIN CHRIS GATES; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties COMMERCIALJINDUSTRIAUREFRIG License no. UNIVERI159RF Effective — expiration 12/06/1985— 04/01/2020 Bond AMERICAN STATES INS CO Bond account no. EX903622 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 03/18/2002 12/06/2001 Expiration date Until Canceled Insurance Help us improve https://securelni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=LTNIVER1159RF&SAW= 5/22/2018 UNIVERSAL REFRIGERATION INC Ohio Cas Ins Co Policy no. BK053333383 $1,000,000.00 Received by L&I Effective date 03/19/2018 04/01/2017 Expiration date 04/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 469,068-01 Doing business as UNIVERSAL REFRIGERATION INC Estimated workers reported Quarter 1 of Year 2018 "31 to 50 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/09/2014 Inspection no. 316993518 Location 6742 185th Ave NE Redmond, WA 98052 Violations Page 2 of 2 () Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600599723&LIC=UNIVERI159RF&SAW= 5/22/2018