Loading...
HomeMy WebLinkAboutPermit PG18-0017 - ACURA OF SOUTHCENTER - RESTROOM FIXTURE UPGRADEACURA OF SOUTHCENTER 301 BAKER BLVD PGI 8-0017 Parcel No: Address: f-.\ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0223100075 301 BAKER BLVD PLUMBING/GAS PIPING PERMIT Project Name: ACURA OF SOUTHCENTER Permit Number: PG18-0017 Issue Date: 2/28/2018 Permit Expires On: 8/27/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: OB FIFE PROPERTY II L L C P 0 BOX 726 , BELLEVUE, WA, 98009 GREG SMALLING PO BOX 65 , REDMOND, WA, 98073 GS MECHANICAL LLC PO BOX 65 , REDMOND, WA, 98073 GSMECML928RK Phone: (206) 372-0332 Phone: (206) 372-0332 Expiration Date: 12/12/2018 DESCRIPTION OF WORK: RESTROOM FIXTURE UPGRADE. REMOVAL OF FIXTURES AND INSTALL NEW. OFFSET TWO (2) TOILET FLANGES TO MEET ADA PER CODE. REPLACE EXISTING ELECTRIC WATER HEATER WITH NEW EQUAL MODEAL. Valuation of Work: $8,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $247.89 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Vth (, VIA/V) Date: 242 ig I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this develo Fn-enermit and agree totthq conditions attached to this permit. Signature: (�1�vu �- — _ Date: vc" c� Print Name: GM�e✓\ of . This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended .or abandoned for a period of 180 days irom the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel.Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: AH plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING \ CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. V Date Application Accepted: lie- /, U Date Application Expires: CI 6 11 Lul (For office us only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 022310-0075 Site Address: 301 BAKER BLVD Suite Number: Floor: FIRST Tenant Name: ACURA OF SOUTHCENTER New Tenant: 0 Yes VI ..No PROPERTY OWNER Name: GREG SMALLING Name: OB FIFE PROPERTY II, LLC Address: PO BOX 65 Address: 301 BAKER BLVD City: REDMOND State: WA City: SEATTLE State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: GREG SMALLING Address: PO BOX 65 Address: PO BOX 65 Phone: (206) 372-0332 Fax: City: REDMOND State: WA Zip: 98073 Phone: (206) 372-0332 Fax: Email. • greg@gsmechanicalshop.com PLUMBING CONTRACTOR INFORMATION Company Name: GS MECHANICAL Address: PO BOX 65 City: REDMOND State: WA Zip: 98073 Phone: (206) 372-0332 Fax: Date: Contr Reg No.: GSMECML928RK Exp 12/12/2018 Tukwila Business License No.: BUS -0993293 Valuation of Project (contractor's bid price): $ 8,000 Scope of Work (please provide detailed information): RESTROOM FIXTURE UPGRADE. REMOVAL OF FIXTURES & INSTALL NEW. OFFSET TWO (2) TOILET FLANGES TO MEET ADA PER CODE. REPLACE EXISTING ELECTRIC WATER HEATER WITH NEW EQUAL MODEL. Building Use (per Int'l Building Code): AUTO SHOWROOM, OFF] Occupancy (per Int'! Building Code): S-1 w/ B NON -SEPARATE] Utility Purveyor: Water: Sewer: HAApplications \ Forms -Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks 2 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) /% Each additional medical gas inlets/outlets greater than 5 v Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal 2 Water heater and/or vent 1 Repair or alteration of water piping and/or water /% treatment equipment v Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 2 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping !/ Each lawn sprinkler system on any one meter including backflow protection devices Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR : UTHOR Signature: Print Name: GRE LING Mailing Mailing Address: PO BOX 65 Date: Z--/c/���' Day Telephone: (206) 372-0332 REDMOND WA 98073 City H:Wpplications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila ecelpt, Number R13793 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $247.89 PG18-0017 Address: 301 BAKER BLVD Apn: 0223100075 $247.89 Credit Card Fee $7.22 Credit Card Fee R000.369.908.00.00 0.00 PLUMBING $231.41 8000.322.100.00.00 0.00 $151.98 PERMIT ISSUANCE BASE FEE R000.322.100.00,00 0.00 PLAN CHECK FEE R000.322.103.00.00 0.00 $46.28 TECHNOLOGY FEE $9.26 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13793 R000.322.900.04.00 0.00 $9.26 $247.89 Date Paid: Wednesday, February 14, 2018 Paid By: GREG SMALLING Pay Method: CREDIT CARD 514151 Printed: Wednesday, February 14, 2018 1:15 PM 1 of 1 riTirrrSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PC, 1 gs — 0017 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION! 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: 01--ocrah deerlor Type of Inspiection: FAIL VI-ctrn bi t/Akti- Address Address: 301 134?dc , , Vcf . Date Called: Special Instructions: Date Wanted:5, C a.m., p.m. Requester: Phone No: pK] Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: zwes? REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 3 X067 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit inspection Request Line (206) 438-9350 (206) 431-3670 Project: /eiJ A b:= 70A}? -TLE Type of Inspection: R6064. -/N pL) YM E I ICr Address: 3cs1 Writ ei_'D Date Called: Special Instructions: Date Wanted: 1—J6 1. . Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 010 PL. Uw►,�iuGK-- R606 -f �Xl Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • TERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0017 DATE: 02/14/18 PROJECT NAME: ACURA OF SOUTHCENTER SITE ADDRESS: 301 BAKER BLVD X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: kJ 00 Building Division Ptiivi t4v Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 02/15/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: Approved with Conditions [—I Denied (ie: Zoning Issues) 03/15/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 GS MECHANICAL LLC Washington State Department of Labor & Industries Home Espanol Contnet Safety & Health Claims & Insurance Page 1 of 2 Search L& A -Z Index Help Mv 1,&.1 Workplace Rights Trades & Licensing GS MECHANICAL LLC Owner or tradesperson Principals SMALLING, GREG, PARTNER/MEMBER SMALLING, GARY, PARTNER/MEMBER Doing business as GS MECHANICAL LLC WA UBI No. 602 564 160 PO BOX 65 REDMOND, WA 98073-0065 206-372-0332 KING County Business type Limited Liability Company Governing persons GREG SMALLING GARY L SMALLING; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. GSMECML928RK Effective — expiration 12/12/2008— 12/12/2018 Bond CBtC Bond account no S11307 $12,000.00 Received by L&I Effective date 12/12/2008 12/09/2008 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS53764777 Received by L&I Effective date 02/13/2018 02/27/2016 Expiration date 01/30/2019 Insurance history Savin9s No savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602564160&LIC=GSMECML928RIUSAW= 2/23/2018 GS MECHANICAL LLC Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workerscomp premiums. L&I Account ID Account is current. 199,947-00 Doing business as GS MECHANICAL LLC Estimated workers reported Quarter 4 of Year 2017 "4 to 6 Workers" L&I account contact T2 / CHRISTOPHER WASSON (360)902-6331 - Email: WASQ235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projec Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during tne previous 6 year period. Page 2 of 2 Washington Stale Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602564160&LIC=GSMECML928RK&SAW= 2/23/2018 ri\loYL } I. ALL SITE PARKINS IS DEDICATED FOR ACURA DEALERSHIP. TOTAL CARS PARKED ARE 21O. �?: FILE COL Y PcrmFA Pio. 1(6 OOfl Plan review o:;. prcvcl is subject to errors and omissions. Approval of cornstruct:on documents does not authorize the violation of any adopted code or ordinance. Receipt of approve fi Copy and c.n.ttions is acknowledged: By: d otAA...., Date: r,2 — l p> City of Tukwila BUILDING DIVISION REVISIONS No changes s1l:111 t:n .m-de to the scope of work witho;;i: prior approve, of Tt�':t^,tile (;, i.'r`ing Division NOTE: Revision:, will rOtillir::) �, rr,='v plan suhmitta! r.-In J may it ude C& tiort2l Ian review fe s CONTACTS BUILDING OWNER O'BRIEN FIFE PROPERY II LLG P.O. BOX 72b BELLEVUE, HA g500c1 (577) 562-1436 ARCHITECT LANGE MUELLER S ASSOCIATES SANDY CONDIOTTY 150 LAKESIDE, SUITE 250 SEATTLE, HA G8122 (206) 325-2553 FAX: (206) 325-0554 SANDYGCLMUELLER.GOM GENERAL FOUSHEE CONTRACTOR I "i iorl'i _ 0 OR: Mcchanical f'Eloc�rrcal ❑ Piu brig gals iping BELLEVUE, HA 425-146-1000 I -STORY 26,66615F INDOOR VEHICLE DISPLAY (BC) INDOOR VEHICLE DISPLAY (I) NVD (I) NVD 5 (2) HC CUSTOMER (I) NVD I) PARKING USED VEHICLE DISPLAY (6) U ED V HICLE 15'°L SALES/ SERVICE ENTRA\IGE/ EXIT SITE PLAN GENERAL NOTES I. SPRINKLER SYSTEMS SHALL COMPLY WITH NFPA 13 AND BE APPROVED BY FIRE DEPARTMENT AND IBC q-1. EXTINGUISHER BY OWNER PER IBC H06.3 WITH 75' MAXIMUM TRAVEL DISTANCE. 2. SUSPENDED CEILINGS TO BE DESIGNED FOR EARTHQUAKE ZONE III, SUBMIT CALCULATIONS TO CITY FOR APPROVAL. 3. CONTRACTOR TO VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS. 4. IN THE EVENT OF FIELD ERROR OR OMISSIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND MAKE NO REPAIRS WITHOUT HIS APPROVAL. 5. CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES TO AVOID INTERFERENCE BETWEEN DIVISIONS OF THE WORK. 6. CONTRACTOR TO PROVIDE ALL WORK, SERVICES, AND MATERIALS NECESSARY TO CONSTRUCT A COMPLETE OPERATING FACILITY. 1. CONTRACTOR SHALL APPLY AND SECURE ALL PERMITS EXCEPT BUILDING PERMIT. HE SHALL PAY ALL NECESSARY FEES AND POST BONDS REQUIRED. 9 i DISTANCE TO PROPERTY LINE FROM EXTERIOR HALL EXISTING ACURA DEALERSHIP I -STORY 55,087 SF INDOOR VEHICLE DISPLAY (30) INDOOR VEHICLE DISPLAY EXISTING AREA SEPARATION WALL GAR WASH (2) CUSTOMER PARKINS (4) \1VD (24)GUSTOV PARKING ER CUSTOMER PARKINS BAKER BLVD. SCALE: 1" = 30'-0" SERVICE RECEPTIO I° L- — . _ SERVICE EXIT L SERVICE ENTRANCE (I) NVD DEFERRED SUBMITTALS ELEGTRIGAL SYSTEM 15 DESIGN/BUILD DEFERRED SUBMITTAL UNDER SEPARATE PERMIT. SYSTEM IS TO CONFORM TO REQUIREMENTS OF THE INTERNATIONAL ELECTRICAL CODE AND WASHINGTON STATE AMENDMENTS. SYSTEM SHALL BE DESIGNED BY A WASHINGTON STATE LICENSED ENGINEER. MOUNTING HEIGHT OF CONTROLS AND RECEPTACLES SHALL COMPLY WITH ANSI II7.1-200q FOR ACCESSIBILITY, AND SHALL BE LOCATED BETWEEN 15" AND 44" FROM FINISH FLOOR. 2. HVAG SYSTEM 15 DESIGN/BUILD DEFERRED SUBMITTAL UNDER SEPARATE PERMIT. SYSTEM SHALL BE DESIGNED BY A WASE-IINGTON STATE LICENSED ENGINEER. SYSTEM IS TO CONFORM TO REQUIREMENTS OF WASHINGTON STATE ENERGY CODE AND INTERNATIONAL ENERGY CONSERVATION CODE. MOUNTING HEIGHT OF CONTROLS SHALL COMPLY WITH ANSI 117.1-200Q FOR ACCESSIBILITY, AND SHALL BE LOCATED BETWEEN 15" AND 44" FROM FINISH FLOOR. 3. SPRINKLER SYSTEM IS DESIGN/BUILD DEFERRED SUBMITTAL UNDER SEPARATE PERMIT. SYSTEM SHALL BE DESIGNED BY A WASHINGTON STATE LICENSED ENGINEER, AND SHALL BE SUBMITTED TO THE PROJECT STRUCTURAL ENGINEER FOR APPROVAL OF POINT LOADS ONLY. SYSTEM 15 TO MEET REQUIREMENTS OF IBC, IFG, NFPA-I3. LOW HAZARD OFFICE OCCUPANCY. NFPA-I3 FIRE SPRINKLER SYSTEM IS REQUIRED. COORDINATE INSPECTIONS AND FINAL INSPECTION WITH LOCAL JURISDICTION FIRE DEPARTMENT. (5) CUSTOMER PARKINS J SALES/ SERVICE ENTRANCE/ EXIT (26) NVD C (2)PERSO PARKI PARTS DELIVERY (12) NEW VEHICLE DISPLAY HI (3)PERS• SAL PARKINS (1 0) VE CL DISPL (6) NV G�J-STOME ARKI JIG SHADING INDICATES AREA OF WORK (I) NVD 0 15 30 SERVICE ENTRANCE/ EXIT ANDOVER PARK WEST SALES/ SERVICE ENTRANCE/ EXIT 60 90 VICINITY MAP NOT TO SCALE VICINITY MAP NOT TO SCALE LEGAL DESCRIPTION TAX ASSESSOR NUMBER: 022310-0075 ANDOVER INDUSTRIAL PARK # 2 POR N OF LN PLW 451 FT S OF 5 MON OF BAKER BLVD LE55 5T ZONING CITY OF TUKWILA ZONING, LATEST EDITION ZONE: TUK-RG SITE AREA: 212,23-1 SF 4.81 AG PROJECT DATA PROJECT SCOPE: INTERIOR REMODEL IN EXISTING AUTO DEALERSHIP. COMBINE TWO EXISTING OFFICES INTO ONE. CEILING AND FLOOR FINISH UPDATES IN SHO1nRO0v AND • SALES AREA. REPLACE WITH ENERGY EFFICIENT LISHTINS =IXTURES. .I•IO. CHANCE. OF USE, EXTERIOR OR SITE WORK, NO CHANCE TO BUILDING ENVELOPE. NO PLUMBING CHANCES. I O GHANSE IN EXITINS. CODES 2015 I.B.G. WITH WASHINGTON STATE AMENDMENTS WAG 51-50 !(G/ANSI A117.1-2000 ACCESSIBILITY STANDARDS CITY OF TUKWILA ZONING 2015 INTERNATIONAL MECHANICAL CODE WAG 51-52 2015 INTERNATIONAL FUEL GAS CODES (IMFGC) 4 WAG 51-52 2015 NATIONAL ELECTRICAL CODE (NEC) 2015 INTERNATIONAL FIRE CODE (IFG) S WAG 51-54 2015 INTERNATIONAL PLUMBING CODE S WAG 51-56 41-51-5-1 2015 ENERGY CONSERVATION CODE 2015 WASHINGTON STATE ENERGY CODES, WAG 51-II INTERNATIONAL BUILDING CODE BUILDINS USE: AUTO SHOWROOM, OFFICE, SERVICE . OCCUPANCY: 5-1. WITH B NON -SEPARATED USE PER IBC 508.3 BUILDING AREA: 81,-156 SF, I -STORY AREA OF WORK THIS. PERMIT: 8,0.17 5F. CONSTRUCTION TYPE: III-B, FULLY SPRINKLERED ALLOWABLE AREA: -10,o00SF SEPARATION INCREASE: BUILDING PERIMETER 1,340' BLDG. PERIMETER OVER 30 FT. 6 • BLDG. PERIMETER OVER 15 FT. SOX655 = 101,650 5F I5X685 = I0,2-15 SF 261,6125 SF / 1340' = • 22.3% TOTAL SEPARATION INCREASE TOTAL ALLOWABLE AREA 3,6102.5 SF (22.3% OF 1-1,500). -13,6102.5 SF RECEIVED CITY OF TUKWILA 6 ;5,REVIEINED FOR '1 CODE COMPLIANCE APPROVED FEB 2 2 2018 City of Tukwila BUILDING DIVISION FEB :1 2018 Greg Smalling . PERMIT CENTER Owner ECHANICAL Commercial Plumbing Heating and Gas Piping GS MECHANICAL, LLC New Address PO Box 65 Redmond, WA 98073-0065 Phone 206 372 0332 greg a@gsmechanicalshop.com PLOT DATE: 7/13/2011 LAVATORY COUNTER PAPER TOWEL / SAN. NAPKIN WASTE DISPENSER SAN. NAPKIN DISPOSAL DUAL LEVEL DRINKING FOUNTAIN TYP. ACCESSIBLE FIXTURE HEIGHTS URINAL TOILET SEAT H.C. STALL ONLY 1 1/2" GRAB BAR TOILET PAPER DISP. NI E J 1 S CORRIDc.R (112).. II I DEMO PLAN O.T..-q . . GT-10 PL-I PF-I I -Fr IN 0 .... HINGEQ..PANEL:::.........................._..... PLUMBING _............ au I i1 LP-1 ST-I 5K- I 55-I WV- I ELEVATION AT MEN LAV (WOMEN SIM.) SCALE: 3/8" =1'-0" WG-I IN EXIST. LOCATIONS S ( 55=1 WOMENS 113 Pip bO"' N D 12'-4" 4'-0" PL -I G-I PL-I FLOOR PLAN G-I WC- I MENS 114 U-I IN EXIST. LOCH 1ON5 NEW FULL HT. HAL STOR 125 55-I PTD SCALE: Y4" =11-0" E -12 I. PROVIDE CONGEALED SUPPORT FOR SS - APPROVED 4' OG. 2. SLOPE FLOOR TO DRAIN (NOT PICTURED). 3. VERIFY CEILING HEIGHT (8'-O" ASSUMED). 4. VERIFY EXIST'S PLUMBING FIXTURE TYPE HUNG IS APPROPRIATE AS DEPICTED. 5. VERIFY LIGHT LEVELS MITH ELEG. GONTR 6. PROVIDE GROUT MOCK-UP FOR OWNER R �. GT-10 BASE. ALL WALLS. CT-q WALL TILE MALLS ADJACENT. 8. 4" PLATE MIRROR WITH STAINLESS EDGE q. PROVIDE LEVER HARDWARE AND. HEAVY STALL DOOR. I. 2X2 X 4 STEEL ANGLE OR AND DETERMINE IF WALL ACTOR. EVIEW. ON WET WALLS AND TOP AND BOTTOM. DUTY HINGES AT ADA FIXTURES AND FINISHES KEY CT-8 FLOOR TILE: 24" SQ. FLOOR GRES CHROMTECH 1.0 COOL 5.0 CT-IQ GR-I CT-q OR-5 P-2 SS- I 5K-I HD -I GT-I PL-I IMIV-I PF-I • VIC-I WG-2 U-I PTD-I BC -I LP -I RL-3 FLOOR TILE COVE BASE: 6"X 12" FLOOR GRES CHROMTECH COOL 5.0 • FLOOR GROUT: HYDROMENT HI3q CHAR BLACK 12" X 24" HALL TILE: DAL -TILE P'ZAZZ GRAY SHIMMER P265 HALL TILE GROUT: HYDROMENT HI65 MYST ENAMEL PAINT HALLS: BENJAMIN MOORE 0C-128 MINCED ONION, SEMI -GLOSS SHEEN FLAT SHEEN ON CEILING. 2GM COUNTER: ZODIAO MYSTIC BLACK SINK: LACAVA AQUABLADE 5030-001 WHITE HANDDRYER: DYSON AIRBLADE V. SPRAYED NICKEL 2" X 2" GLASS TILE CROSSVILLE GLASS BLOX G041 MOONBEAM PLASTIC LAMINATE PARTITIONS $ URINAL SCREENS : FORMICA BLACK q0q-58 MATTE WOOD VENEER: TABU VENEERS ANESRE 01.051 SENSOR FAUCET: SLOAN ETF-80-4-P-BDT OR AMERICAN STD. MOMENTS SELEGTRONIG 2506.165 .5 GPM HATER CLOSET: VERIFY KOHLER K4406 SEAT: CHURCH #3155G HATER CLOSET ADA: VERIFY KOHLER K4405 URINAL: KOHLER 4g04-ET .SGPF HALL HUNG PAPER TOWEL DISPENSER: BOBRICK B-3g44 BABY CHANGING STATION: KB-IIO-SSRE 3l"X 23" LED PENDANT: EUREKA 4162-NAH-X-RG-CHR-CLR- qW LED PAR 20 6 RECESSED LED: LITON LHALD 625 GENERAL DEMOLITION NOTES r � I I REMOVE DASHED DOORS, HALLS, FIXTURES, TYP. I. ALL EXISTING DOORS, RELITES, FRAMES, AND HARDWARE DESIGNATED TO BE REMOVED, SHALL BE SALVAGED FOR RE -USE TO THE MAXIMUM EXTE POSSIBLE AND PRACTICAL. REVIEW :D FOR CODE COMPLIANCE 2. SALVAGE AND REUSE ELECTRICAL DEVICES SUCH AS• OUTLETS, SHIT ED APPROVED BOXES, A.V. CONTROLS, SENSORS, 'THERMOSTATS, ETG.TO THE MAXIM ; EXTENT PRACTICAL. 3. CEILING TILES, FIXTURES, GRID, DIFFUSER GRILLES, ETC. SHALL BE S FOR RE -USE TO THE MAXIMUM EXTENT PRACTICAL. 4. EXISTING SURFACES AND FINISHES SHALL BE PATCHED, REPAIRED, A [BUILDING DI FINISHED TO MATCH EXISTING SURROUNDING SURFACES. REPLAGEME T ANv REPAIR OF FINISH MATERIALS SHALL MATCH EXISTING WHEN PRACTICAL. GENERAL FLOOR PLAN NOTES 1. OFFSET EXISTING CLOSET FLANGES TO COMPLY WITH NEW ADA WATERCLOSET STALLS. RECEIV 2. PROVIDE ASSE 1070 MIXING VALVES ON ALL LAVATORIES CITY OF TUK FEB 1 4 2 PERMIT CE 3. PROVIDE ADA P-TRAP BOOTS Qoo ( FEB 22 2Q18 VAGED City of Tuk !SIGN 1 ILA PLOT DATE: IO/20/201S rn 3 C N 0 C C C 0 0 C C C 0 0 C% 3