HomeMy WebLinkAboutPermit PG18-0046 - TRAN RESIDENCE - REMOVE/REPLACE GAS WATER METERTRAN RESIDENCE
10709 47T" AVE S
PG1 8-0046
Parcel No:
Address:
Project Name:
/\
City of Tukwila
a
t of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
WATER HEATER PERMIT
5476800068 Permit Number: PG18'0046
10709 47TH AVE S
TRAN RESIDENCE
Issue Date: 3/27/2018
Permit Expires On: 9/23/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
HOANGKHA+CM8|5TYIRAN F[A
1O7O947THAVE S,TUKWILA, WA,
98178
KATY KEHLE
11715 N CREEK PKWY 5 #C-106,
BOTHELL, WA98011
FAST WATER HEATER COMPANY
1171SNCREEK PKWY S5T[[-10G,
BOTHELL, WA, 98011
License No: FASTWWH948BC
Lender:
Name:
Address:
'''
Phone: (425) 636-7084
Phone: (425) 636-7084
Expiration Date: 1/4/2020
DESCRIPTION OF WORK:
REMOVE/REPLACE GAS WATER METER
Valuation ofWork: $1,441I0
Water District: TUKWILA
Sewer District: TUKWILA
Fees Collected: $49.80
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
nternational Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
2017WA State Energy Code:
2017
2017
2015
Permit Center Authorized Signature:
6
Date: /���+~
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signa
Print Name77,',, �y%z(Cc ✓�
Date; ?� 27 7
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 gauge.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1900 PLUMBING FINAL
8005 ROUGH -IN PLUMBING
Community Development Department
Permit Center /
6300 Southcenter Blv&, o'uite 100
Tukwila, WA 98188
:1iwww. FukwilaWA.a.�ov
Plumbing/Gas Permit No.
r '\
Project No.
Date .pplicatign Accepted:. o 5/a 7//S
Date Application Expires:
(For- office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address:
Tenant Name:
(WI u - /oua S
-10-k1
King Co Assessor's Tax No.: 5 47 .)3D- - L LY p
Suite Number: Floor:
PROPERTY OWNER
Name: K H A 1' i Vt t-rMM?
Address:
-o LI S
City:\c_i /j, State: Mk\ Zip: Op �Q
CONTACT PERSON — person receiving all project
communication
Name: KA -7\i /V—'i -k- /l
Address: I \ -4. (N-vN S '
State:
City: Z.) 0 j,1 „ „ , 1
Zip: 6\ V \
ui �
Phone: ypj 72,i Dtg�Fax: !r 5-63(sjOV
�j
Email: K K.E l .RkS4.,\lj 00..e a � , (,pVVt
New Tenant: ❑ Yes
0
PLUMBING CONTRACTOR INFORMATION
Company Name: f/ STA i - e - .-e ii,
"
Address: 1 t sJ NI �- .C—1 0 C
City: VO -At l State: W Zip:(1 '01
i
1
Phone:ds' Lo "1 ifFax: LAgs vs 0„.0
„.
ws
Contr Reg No.: pc5..--ww cAL4c�e,CExp Date: \_ . , Is
Tukwila Business License No.: i2,u5 — 6tf q (.03p0
Valuation of Project (contractor's bid price): $
IV1I
Scope of Work (please provide detailed information): -et.( i by --e,1 \(-e9, SAI -S
VAeCA }(
Building Use (per Int'l Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water:
H:Wpplications\Forms-Applications On Line1201 I ApplicationslPiumbing Permit Application Revised 0-9-I Ldocs
Revised: August 2011
bh
Sewer:
Page I of 2
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type
QtY
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
RaM water system — per
draM (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Fixture Type
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler back -Bow
protections over 5
\
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
- commercial -
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
Fixture Type
QtY
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction arnount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review —Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND T AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING 0 NER OR AUTHORIZED AGENT:
Signature:
Date 3
Print Name: KA -T4 Day Telephone: 0 10 3 tiq-0
Mailing Address: 1 I -.15 PJ 0F,4K_P3.v\-0-1 S (fi 30 -HA -Q- I 1 L4jk 'DII
City State Zip
HAApplicationsWorrns-Applications On Line\ 2011 Applications \Plumbing Permit Application Revised 8-9- t t .docx
Revised: August 2011
bh
Page 2 of 2
ash Register Receipt
City of Tukwila
DESCRIPTIONS
Perm itTRAK
ACCOUNT
QUANTITY
PAID
$49.80
PG18-0046 Address: 10709 47TH AVE S Apn: 5476800068
$49.80
PLUMBING
$47.43
R000.322.100.00.00
0.00
111111111111111
WATER HEATER FIXTURE FEE
R000.322.103.00.00
0.00
$14.28
TECHNOLOGY FEE
$2.37
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14087
R000.322.900.04.00 0.00
IIIIIMEN
$49.80
Date Paid: Tuesday, March 27, 2018
Paid By: FWH ACQUISITION COMPANYLLC
Pay Method: CHECK 4410
Printed: Tuesday, March 27, 2018 10:27 AM
1 of 1
rfillfirSYSTEMS
INSPECTION NO,
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Proj g.t.;---
i retel ("ReTclterv-e
TypyLspection:
vi.031,-‘62- Final -
Address: Zit
/07D 7 10 14-vc__ S .
Date Called:
Special Instructions:
101. oe, A. on ,
Date Wanted:
Li- Z7 - 221g---
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
Date: q-27 201/
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
FAST WATER HEATER COMPANY
Home Espanol Contact
Safety & Health Claims & Insurance
CWashington State Department of
O Labor & Industries
Page 1 of 3
Search L&I
A-!. Index Ilelp My 1 &I
Workplace Rights Trades & Licensing
FAST WATER HEATER COMPANY
Owner or tradesperson
Principals
JORDAN, JEFFERY
DAVID, PARTNER/MEMBER
HANLEYBROWN,
JASON, PARTNER/MEMBER
11715 N CREEK PARKWAY S, C-106
BOTHELL, WA 98011
425-814-8381
KING County
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
....._......._......................._...........
Meets current requirements.
License specialties
GENERAL
License no.
FASTWWH948BC
Effective — expiration
01/03/2006— 01/04/2020
Bond
DEVELOPERS SURETY & INDEM CO
Bond account no.
549792C
$12,000.00
Received by L&I Effective date
01/03/2006 01/01/2005
Expiration date
Until Canceled
Insurance
American States Insurance Co $1,000,000.00
Policy no.
01C155607670
Received by L&I Effective date
02/23/2018 02/17/2018
Expiration date
02/17/2019
American States Insurance Co $1,000,000.00
Policy no.
01C155607661
Received by L&I Effective date
02/16/2018 02/17/2017
Expiration date
02/17/2019
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602564544&LIC=FASTWWH948BC&SAW= 3/27/2018