Loading...
HomeMy WebLinkAboutPermit PG18-0053 - RAINIER INDUSTRIES - INSTALLATION OF NEW COMPRESSED AIR LINESRAINIER INDUSTRIES 6700 S GLACIER ST PGI 8-0053 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 7888900080 6700 S GLACIER ST PLUMBING/GAS PIPING PERMIT Project Name: RAINIER INDUSTRIES Permit Number: PG18-0053 Issue Date: 5/15/2018 Permit Expires On: 11/11/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: C/O PROLOG'S - RE TAX 1800 WAZEE ST, DENVER, WA, 80202 IAN MAYTHER 18375 OLYMPIC AVE S , TUKWILA, WA, 98188 RAINIER INDUSTRIES LTD Address: 18375 OLYMPIC AV 5 , TUKWILA, WA, 98188 License No: RAINI11066QP Lender: Name: Address: 1 Phone: (425) 9814220 Phone: (425) 2514800 Expiration Date: 1/11/2019 DESCRIPTION OF WORK: INSTALLATION OF NEW COMPRESSED AIR LINES Valuation of Work: $15,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $532.72 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Da 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditio s attached to this permit. Signature: Print Name: :1-2/114 mity Date: Zola" cD . IS This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILt; Community Development apartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas ;Lit No: 6/0--0053 Project No. Date Appikation Accepted: Date Appi%ttion E piress to -c--(6 (F` ce use only} PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: X88 8100586 Site Address: (•BOO S • G1 UAC 1Ei2 'T Suite Number: Floor: �.. Tenant Name: t yatr E 2- 1.hlDUSTYZ New Tenant: Yes ❑.. No PROPERTY OWNER Name: �+20t.00 4 .Ct11L Address: L7-'3-2 O C VITEWAA') 'D Q, Sus[" E 1\O City: ..V V-W.L114 State: SIA z>p.99 16A CONTACT PERSON — persona COMM n Cation Name: 1-1004 imviyivos Address: leS3S OLy yirL 14VE S State: G Zip: i8 )lS City: 1u,)ia.W Phone: Fax: 42S-2Si-sb6c Email: Zveon.twie R L. COW\ PLUMBING CONTRACTOR INFORMATION Company Name: avvv,,ttsYL iim cw6.112.1.s Address: /835 QL maze, AvE S City: To vC..I�wWr State: $.3A, 78)88 Phone: ins-- Cj8)- )'AZO Fax: Las-- 2€1- 5-0(0S Contr Reg No.: ZS1A(i(0W Exp Date: O`/ 1 /'q Tukwila Business License No.: R«S --AIOOAZb Valuation of Project (contractor's bid price): $ 15/ OOo Scope of Work �'.1(please provide detailed information): 1K15rA�.L-WTI (hF SEW COW)p 2E t p9 Li+G lr' y• d•e Building Use (per Int'I Building Code): Occupancy (per Int'l Building Code),, F • Utility Purveyor: Water: �. • H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh 00 ' Sewer: Page 1 of 2 owe Indicate type of plumbing fixtures and/0Cpiping outlets being installed and the quantit}„.ow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per dram (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED •` NT: Signature: Print Name: 1htf.1 VVI{ }1 Mailing Address: /83-K.- ©tIMPLZ 14VE S H:\ApplicationsWorms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 7018 -©y- Day Telephone: in 6 - 5 $V - ) t70 I uKtAV2A4- G014- 98fe8 City State Zip •• Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R14163 PermitTRAK DESCRIPTIONS ACCOUNT QUANTITY PAID PG 18-0053 Address: 6700 S GLACIER ST Apn: 7888900080 Credit Card Fee 2.72 $15.52 Credit Card Fee R000.369.908.00.00 0.00 $15.52 PLUMBING $497.31 PERMIT FEE R000.322.100.00.00 0.00 $364.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $99.46 TECHNOLOGY FEE $19.89 TECHNOLOGY FEE R000.322.900.04.00 0.00 $19.89 TOTAL FEES PAID BY RECEIPT: R14163 $532.72 Date Paid: Thursday, April 05, 2018 Paid By: IAN MAYTHER Pay Method: CREDIT CARD 066077 Printed: Thursday, April 05, 2018 11:45 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit P6-,-0053 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: JN IER /N17USTRjIES Type of Inspection: pLO4t'16- AMG Address: (Ro 5, a4t/ec M2 Date Called: Special Instructions: PL .),18/NG Fflt h�. Date Wanted: r /D —/'?.-/E3 p.m. Requester: /44/ / x_y7/$ye Phone No: 9255— /i Approved per applicable codes. a Corrections required prior to approval. COMMENTS: t Inspector: Date:ib 9 I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P618-005,3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ct:. irlf-ene • 1 of Inspection: - Address: 67 or, cc. GI, „ if _ el Date C ed: Special Instructions: Date Wanted: - Pa. . • • Requester. Phone No: 5 61 -CM "- ATAppmved per applicable codes. Corrections required prior t -o approval. COMMENTS: 44- -T-tkirALL FJecj4v Corm,p yersVir ic 0-rc_ dvt) Inspector: E Date: 7.10 c 2.018/1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ABT 206-369-6178 Backflow Prevention Assembly est Report yo �� Water District — 1 7-7:0.1/ %S �GCG y /� cid �►� ler,./rt SERVICE ADDRESS 474:" 5 - CONTACT PERSON ti'Q1/lf NAME OF PREMISE q/AC ger �� crry 771(w,..4 LOCATION OF ASSEMBLYi�i mmercial f1Residential, 0 ZIP PHONE i.1-4* 7T.3 - '00 FAX ( ) 44,04't f1.1 14-4f. DOWNSTREAM PROCESS DCVA 0 RPBRPB$5 PVBA i. OTHER NEW INSTALL 0 EXISTIN REPLACEMENT 0 OLD SER., # PROPER INSTALLATION? YEY'C1 10 0 MODEL / Q D%/ t3 4Q/SERIAL NO. -� Ca✓ SIZE ��y+ MAKE OF ASSEMBLY 1449i1-4 INITIAL TEST PASSEDID FAILED 0 DNA I RPBA DCVA / RPBA RPBA PVBA/SVBA CHECK VALVE NO.1 CHECK VALVE NO.2 OPENEDATJ-7 PSID AIR INLET OPENED AT PSID LEAKED 0 g''s PSID LEAKED 0 /%ice 71PSID #1 CHECK X-C—PSID NOT OPEN 0 AIR GAP OK?,) NEW PARTS AND REPAIRS CLEAN REPLACE PART ❑ ❑ CLEAN REPLACE PART ❑ ❑ CLEAN REPLACE PART CHECK VALVE HELD AT PSID • II LEAKED 0 0 0 0 0 0 0 ❑ ❑ • ❑ • ❑ CLEANED 0 REPAIRED 0 ❑ ❑ ❑ ❑ ❑ TEST AFTER REPAIRS LEAKED 0 PSID LEAKED 0 PSID OPENED AT PSID AIR INLET PSID #1 CHECK PSID CHK VALVE PSID PASSED ■ FAILED 0 AIR GAP INSPECTION: Required minimum air gap separation provided? Yes< No 0 Detector Meter Reading REMARKS: LINE PRESSURE / TESTERS SIGNATURE: TESTERS NAME PRINTED: REPAIRED BY: CERT. NO. B6796 CONFINED SPACE? PSI DATE /—i'& 7 F� Bryan Vangstad TESTERS PHONE # (206) 369-6178 FINAL TEST BY: DATE CALIBRATION DATE CERT. NO. DATE 06 / 28 / 2018 GAUGE # 12160608 MODEL Midwest 845-5 SERVICE RESTORED? Y 1 certify that this report is accurate, and 1 have used WAC 246-290-490 approved test methods and test equipment. NO 0 April 11, 2018 City of Tukwila Department of Community Development IAN MAYTHER 18375 OLYMPIC AVE S TUKWILA, WA 98188 RE: Correction Letter # I PLUMBING/GAS PIPING Permit Application Number PG18-0053 RAINIER INDUSTRIES - 6700 S GLACIER ST Dear IAN MAYTHER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. The plan only indicates blue pipe, red hose with no explanation. Provide clarification with specifications for all compressed air piping and hoses. Specifications shall indicate the manufacturers UL ratings for maximum air pressure allowed with installation information. 2. Show isolation shut off valves and their locations. Please be specific about the piping fittings etc. and show the fittings are rated for this type of assembly. 3. Specify the maximum air pressure that shall be used for the system. Show air filter and air regulators and similar components that shall be part of the system. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. LInn C.__../_____. __ nuinn T.L...:l.. IIl....L:.-.-..... A9/94- OL......711.0 421 2.c711.- L'.... 1A.r_A2/_2X/Ci Sincerely, 72)(j.0 Bill Rambo Permit Technician File No. PGI8-0053 <71111 ...L .. _ n ..i .. _a r.,:.. 4111n • T..h..:l.. Were hi.......... 021 RR a Phnna gni( I.iit7n • Fnr 7/IF.431_?i 6.5 CPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0053 DATE: 05/04/18 PROJECT NAME: RAINIER INDUSTRIES SITE ADDRESS: 6700 S GLACIER ST Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: C C-6 6 Building Division IN Public Works Ell Fire Prevention Structural Planning Division 1111 Permit Coordinator LI LI PRELIMINARY REVIEW: Not Applicable Lil (no approval/review required) DATE: 05/08/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved Approved with Conditions Corrections Required LIDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 06/05/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 StaffInitials; 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0053 DATE: 04/05/18 PROJECT NAME: RAINIER INDUSTRIES SITE ADDRESS: 6700 S GLACIER ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �S Cov1r 2 't-10-18 Building Division 111 Fire Prevention Public Works Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 05/08/18 ❑ Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 10\--1 1-1 Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Wit moi- 30 Plan Check/Permit Number: PG18-0053 ❑ Response to Incomplete Letter # ® Response to Correction. Letter # 1 O Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Rainier Industries Project Address: 6700 s Glacier St Contact Person: TIA.KI 104Av y-rg Summary of Revision: _1. lam m+lf i ._.!!• Ind Phone Number: /ZS' - 7BI - 1272) Wo -re -C: E 2 VIE Z u sy6T67/14 PI 0602F RECEIVED CITY OF TUKWILA APR 3 1 2018 PERMIT CENTER Sheet Number(s): P -P 2 - "Cloud" "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: ❑ Entered in TRAKiT on C:\Users\bill-r\Desktop\Revision Submittal Form.dac Revised: August 2015 isi RAINIER INDUSTRIES LTD home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries [Search L&I Page 1 of 3 A A-7, Index kip My. L&1 Workplace Rights Trades & Licensing RAINIER INDUSTRIES LTD Owner or tradesperson Principals CAMPBELL, SCOTT CURTICE, PRESIDENT CAMPBELL, KAREN LYNN, VICE PRESIDENT SCHOONMAKER, GEORGE W (End: 01/01/1980) SCHOONMAKER, GEORGE W, AGENT (End: 01/01/1980) Doing business as RAINIER INDUSTRIES LTD WA UBI No. 600 523 816 18375 OLYMPIC AVE S TUKWILA, WA 98188 425-251-1800 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Awnings, Canopies, Patio Covers, Exterior Screens License no. RAINIIL066QP Effective -- expiration 11/17/1994— 01/11/2019 Bond CBIC Bond account no. LB6600 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 09/16/2002 10/01/2002 Expiration date Until Canceled Insurance Phoenix Insurance Company, The $1,000,000.00 Policy no. 6300532991 Received by L&I Effective date 12/22/2017 12/31/2016 Expiration date 12/31/2018 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600523 816&LIC=RAINIIL066QP&SAW= 5/15/2018 7 8 9 10 11 12 13 14 15 17 ISION HISTORY REV . s DESCRIPTION BY DATE APPR A IRM 41312018 PROPERTY LINE ICe rn CO PROPERTY LINE • • • Existing Driveway • • Olympic Avenue S PARKING LOT F ......••••••••••••••••••••••••••• ................................. ................................. ............................... PROPERTY LINE Olympic Ave S PARKING LOT B'T 6700 S. GLACIER ST TUKWILA, WA 98188 PARCEL #7888900080 IBC OCCUPANCY CLASS: F FACTORY SQ FT: 22,000 OFFICE SPACES . . . . . • • • • • • • • • • • • • ................. ReftDDTukwilalGtatier BuildingV01- Automation (BB)\Svstem Drawings\Rainier - Spray Processing - Rev11.7.dwq Existing Fenced Area 178'•4" am 41 __ft Existing Driveway a Loading Dock PRODUCTION FLOOR Pt. a /'\ Existing a a 4 • • • ..•.• ....................................................... ........................................................ ....................................................... ......................................................... ......................................................... ......................................................... ......................................................... .......................................................... ......................................................... •.......................................................... • Plan View O Scale: i" =1'-0" • PROPERTY LINE LiQ CM 02" BLUE PIPE CM 011 RED HOSE W/ON/OFF VALVE Sidewalk CD 6700 S. GLACIER ST TUKWILA, WA 98188 PARCEL #7888900080 IBC OCCUPANCY CLASS: F FACTORY SQ FT: 22,000 • OFFICE SPACES 02" BLUE PIPE —\ii 01" RED HOSE W/ON/OFF VALVE 02" BLUE PIPE 01' RED HOSE )W/ON/OFF VALVE 41* (31" RED HOSE W/ON/OFF VALVE 01" RED HOSE W/ON/OFF VALVE 01" RED HOSE W/ON/OFF VALVE RED HOSE W/ON/OFF VALVE 02" BLUE PIPE —\ RESP0NSE CHANGES IRM exam FUNCTION: INSTALL NEW COMPRESSED AIR PIPING COMPIIESSOR AND AIR DRYER COVERED UNDER (1) MECHANICAL PERMIT PIPING COVERED UNDER (1) PLUMBING PERMIT ORIGINAL DESIGN CONCEPTS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAWS AND ARE TEH PROPERTY OF RAINIER INDUSTRIES, LTD. ANY REPRODUCTION OF THIS DESING CONCEPTS WITHOUT WRITTEN CONSENT IS EXPRESSLY FORBIDDEN. Loading Dock (BY OTHERS) Poradit Moo 003 APPrafel el construction docummis doss not authorize the violation of any adopted code or ordinance. Receipt of approvod Field Copy and conditions is acknowledged: y: c67 RED HOSE W/ONIOFF VALVE 717 01" RED HOSE W/ON/OFF VALVE City of Tulaivila BUILDING DIVISION SEPAr,:l.ATE PERMIT fiziQUIRED FOR: CaMothart- Cebas PRODUCTION FLOOR Ciiy of Rain -la "ILDING DIVISION OT BLUE PIPE fil? RED HOSE W/ON/OFF VALVE 0i* RED W/ON/OFF VALVE HOSE MI 02" BLUE PIPE 01' RED HOSE W/ON/OFF VALVE Compressed Air Layout ® 0? RED HOSE W/ON/OFF VALVE AIR COMPRESSOR AND AIR DRYER COVERED UNDER PERMIT #M18-0044 fiii" RED HOSE W/ONIOFF VALVE tztl 01" RED HOSE W/ON/OFF VALVE CM MI l\to Onn,01.1s she!! be 'nada to the scope krtay ineudo additions! Wm' meow teas. 01" RED HOSE 01" RED HOSE W/ONIOFF VALVE W/ON/OFF VALVE REVIEWED FOR CODE COMPLIANCE APPROvw MAY 11 2010 Vtit City of Tukwila 01" RED HOSE W/ON/OFF VALVE CORRECTION LTR# ga Vol wL 02" BLUE PIPE 02" BLUE PIPE 02" BLUE PIPE 444 SHEET INDEX PAGE SHEET DESCRIPTION DEPARTMENT P1 PLAN VIEW P2 RISER DIAGRAM COMP. AIR LAYOUT RAINIER INDUSTRIES PLAN VIEW RAINIER INDUSTRIES LTD votoreman-- 111232 1 2 3 4 7 8 9 10 11 12 13 14 15 16 17 REVISION HIST REV DESCRIPTION BY DATE A COMP. AIR LAYOUT 4/3/2018 02' BLUE PIPE AIR-FILTERIREGULATOR COMBO SET TO 100 PSI MAX. REGULATOR RATED TO 150 PSI EXISTING AIR COMPRESSOR ON/OFF VALVE ©22" BLUE PIPE -TO -RED HOSE TYP RATED TO 800 PSI 0? RED HOSE 0? RED HOSE 00' RED HOSE EXISTING AIR DRYER LOCKABLE ON/OFF VALVE TYP© HOSE -TO -EQUIPMENT RATED TO 800 PSI 0? RED HOSE 0,?' RED HOSE 'EXISTING EQUIPMENT COVERED UNDER PERMIT M18-0044"' 0l' RED HOSE 0? RED HOSE 0?" RED HOSE 0' RED HOSE 0}' RED HOSE 0? RED HOSE 0? RED HOSE 01" RED HOSE 0? RED HOSE RED HOSE 0? RED HOSE 0?'RED HOSE 0? RED HOSE Isometric Plan View A Scale: i" = 9 -0° ENGINEERED SPECI11LTiEs, LLC 6111 Mill creek .Drive Phone: (715) 869-6044 Auburndale, WI 54412 Fax: (715) 869-6047 vvww.'rapidair pnuluc ts.vom in idairprexlttcts.c om Letter of Compliance 1-2018 Product Description: Modular compressed air piping system 3/4" thnr 6" Fastpipe Techni d Sere rtions: Compressed air, vacuum, and inert gas applications 190 psi maximum working pressure , Temp lunge 0°' F to 140° F Compatible with common compressor lubricants Geucral Ealimes: ASME B31.11 UL94HB fue resistance, Compliant to OSHA Material: Aluminum alloy grade 5042 Blue powder coat, color RATS012 outside Non chromate conversion coating inside Trade size callout measured with D.D. 3/4" size 20rmn .79 OD x .69 U). 1" size 25mm .98 0.1) x .8713U. 1-1/2" size 40mm 1.57 O.D x 1.43 I.U. 2" size 50mm 1.97 0.D x I.81 1.D. 3" size ROrr an 3.15 0.D x 298 T.D. 4" size 100mnt 4.20 OD x 3.781.i). 6" size 150nttn 6.02 OD x 5.751.D. Compression style 3/4" thm 2" Body: nylon 6 with fdyerglass reinforcement, blue color 3" Body: Diecast aluminum then electrocoatcd, black color Bite ring stainless steel U-Ring. nitrite Compression style 3" Body: Diccast aluminum, then electrocoated, black color Bite ring stainless cril 0-Ring nitrite Lug Style 4" -6" Body: Dimwit altnninunt/ Steel, Pawdacoat Inner Seal: nitrite Coi ssed Piping Systei 5 UL Listing Scale: N.T.S P\Raf6tD\Tukwila\Glacier Building\01- Automation (BB)\System Drawings\Rainier - Spray Processing - Rev11.7.dwq R VIE I ED FOR CODE COMPLIANCE APPROVED MAY .. 201f City of Tul .+ill BUILDING DIVISION G APR 302018 �R COMP. AIR LAYOUT =t114' JO(= ± 1/1E ANGLES = ± 1° RAINIER INDUSTRIES PLAN VIEW RAINIER INDUSTRIES LTD . 111232 P2