Loading...
HomeMy WebLinkAboutPermit PG18-0062 - T-MOBILE - TENANT IMPROVEMENTT -MOBILE 984 SOUTHCENTER MALL PGI 8-0062 Parcel No: Address: City of Tukwila a of Department Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438'9350 Web site: http://wwnw.Tukmi|mVVA.nmv PLUMBING/GAS PIPING PERMIT 9202470010 Permit Number: PG10'0062 984 SOUTHCENTER MALL Project Name: T -MOBILE Issue Date: 5/30/2018 Permit Expires On: 11/26/2018 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: POBOX 13O94O'CARLS8AD'WA, 92013 Contact Person: Name: APRIL HOUSE Address: 3617SVVCHARLESTON ST'SEATTLE, WA, 98126 Contractor: Name: HAWK BUILDING CONTRACTORS INC Address: POBOX 996'FERNDAL[,WA, 88248 License No: HAVVK80034PK8 Lender: Name: Address: ''' Phone: (206) 478-0844 Phone: (425) 402-1818 Expiration Date: 5/29/2020 DESCRIPTION OF WORK: TENANT IMPROVEMENT Valuation of Work: $10,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $184.97 Current Codes adopted by the City of Tukwila: International Building Code Edition: laternational Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 20152015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 Lt Lc---3044- .perm|t[ente,4uthorized5iAnatu,e: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development , = mit and agree to the conditions attached to this permit. Signature: Print Name: S Date: 3? I� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The owner or his representative shall submit a KC Non -Residential Sewer Use Certification form listing all the new plumbing fixtures. Do not list fixtures replaced in kind. 2: The owner or his representative shall submit a KC Non -Residential Sewer Use Certification form listing all the new plumbing fixtures. Do not list fixtures replaced in kind. 3: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 4: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 5: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 6: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 7: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 8: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 9: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 10: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 11: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 12: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 13: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 14: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 15: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 16: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. fliA (WV/ Project No. V? �, // Date Application Accepted: '�''' �' Date Application Expires: � ' f+1 1 (For office e only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 984 Southcenter Mall T Mobile PROPERTY OWNER Name: April House-Paroline and Associates Name: Westfield City: Seattle State: WA Zip: 98126 Address: 835 Market St, Suite 517 Email: april@parolineassociates.com City: San Francisco State: CA Zip: 94103 CONTACT PERSON — person receiving all project communication Name: April House-Paroline and Associates Address: 3617 SW Charlestown St City: Seattle State: WA Zip: 98126 Phone: (206) 478-0844 Fax: Email: april@parolineassociates.com King Co Assessor's Tax No.: Suite Number: 440 Floor: New Tenant: VI Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 10,000 Scope of Work (please provide detailed information): Tenant Improvement Building Use (per IntlBuilding Code)- Retail Occupancy (per Int'I Building Code): M Utility Purveyor: Water: Sewer H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx Revisal: August 2011 bb Page 1 of 2 Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks 2 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 1 Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER IR THORI AGEN • Signature: Print Name: April House-Paroline and Associates Mailing Address: 3617 SW Charlestown St HAApplicatiomWorms-Applications On Line \2011 AppbcatiomaPlumbing Permit Appli Revised: August 2011 bh Revised 8-9-11.docx Date: Z 3 /18 Day Telephone: (206) 478-0844 Seattle WA 98126 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila D18-0112 Address: 984 SOUTHCENTER MALL, DEVELOPMENT ACCOUNT ( QUANTITY Apn: 9202470010 PAID $1,530.11. PERMIT FEE R000.322.100.00.00 0.00 $924.61 PLAN CHECK FEE R000.345.830.00.00 0.00 $601.00 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $46.23 TECHNOLOGY FEE R000.322.900.04.00 0.00 $46.23 EL18-0388 Address:. 984 SOUTHCENTER MALL pn: 9202470010 29.6! ELECTRICAL $797.78 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $638.22 PLAN CHECK FEE R000.345.832.00.00 0.00 $159.56 TECHNOLOGY FEE $31.91 TECHNOLOGY FEE R000.322.900.04.00 0.00 $31.91 M18-0054 Address: 984 SOUTHCENTER MALL pn: 9202470011 MECHANICAL $702.41,; PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $528.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $140.48 TECHNOLOGY FEE $28.10 TECHNOLOGY FEE R000.322.900.04.00 0.00 $28.10 PG18-0062. ress: `984SOUTHCENTER'M n: 9202470010 PLUMBING $177.86 PERMIT FEE R000.322.100.00.00 0.00 $109.14 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $35.57 TECHNOLOGY FEE 17.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14314 R000.322.900.04.00 0.00 $7.11 $3,321.51 Date Paid: Monday, April 23, 2018 Paid By: PRECISION PERMIT Pay Method: CHECK 15894 Printed: Monday, April 23, 2018 12:49 PM 1 of 1 CRSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje • Typt_gf Inspectiprii, 0-1A "1110 I 1\) F t NI -Art - ,.. Mot I IT, Poldress:_ . . . , (185 So.,1/471-ce,Aer n6,11_ Date Called: ,--- , Special Instructions: Date nted: 3 P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Datey.iy REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Role-Oaz 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro'ec T of Inspec ion; PL ` Address: X81 .satti-tte�cry - 11 _ Date Calle penal Instructions: Date Wanted: 7 - 2- zni a.m. p -m. Requester: Phone No: c5-:1 LJ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspect Date: -7,z z4:7„ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ERMIT WORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0062 DATE: 04/25/18 PROJECT NAME: T -MOBILE SITE ADDRESS: 984 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ky /*C. \--1—(6 Building Division III Public Works Fire Prevention Structural LI Planning Division ElIPermit Coordinator LI LI PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 04/26/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: Approved Approved with Conditions Corrections Required LIDenied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 05/24/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 Non -Residential SewerAse Certification Sewage Treatment Capdtafty Charge PG I6 To be completed for all new sewer connections, reconnections or change of use of existing connections. Please Print or pe T6L1 S0 her M.Q,XL Property Street Address City State ZIP Owner's Name Owner's Mailing Address City State ZIP Owner's Phone Number including Area Code Property Contact Phone Number including Area Code Party to be Billed (if different from owner) Address City State ZIP A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 1 : . Hose bibb (interior) 2.5 2.5 Clothes washer or laundry tub 4 2 Sink, bar or lavatory 2 1 Sink, Clinic flushing 8 8 Sink, kitchen 3 2 j Z.. Sink, other (service) 3 1.5 ( I , .— Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Water closet, tank or valve, 1.6 GPF 6 3 Water closet, tank or valve, >1.6 GPF 8 4 Total Fixture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total Fixture Units _ 20 0.Z RCE King County Department of Natural Resources and Parks Wastewater Treatment Division For King County Use Only Account # No. of RCEs Monthly Rate PropertyTaxlD# q20;21470010 Subdivision Name Lot # Subdiv. # Block # Building Name (if applicable) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre-existing structures on this property. Credit for a demolition may be given under some circumstances. (See King County Code 28.84.050, 0.5) Demolition of pre-existing structure? ❑ Yes ❑ No Was structure on Sanitary Sewer? ❑ Yes ❑ No Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date Type of structure demolished Request to apply demolition credit to multiple structures? ❑ Yes ❑ No B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility/Process: Estimated Wastewater Discharge: Gallons/days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal/day) _ 187 RCE C. Total Residential Customer Equivalents: (add A & B) A 0, Z. +B 0 Z Total RCE Pursuant to King County Code 28.84.050, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the Metropolitan King County Council at a rate per month, per residential customer or residential customer equivalent, for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-477-5516. I understand that the information given is correct. I understand that the capacity charge levied will be based on this information. I understand that oa deviation may result in a revised capacity charge. Signature of Owner/Representative Date 5-4"/e Print Name of Owner/Representative k,i'A A�1, 5 1610_6969w_nonres_sewer_cap_chg_1056.indd White - King County Yellow - Local Sewer Agency Pink - Sewer Customer (Rev. 10/16) ' *• HAWK BUILDING CONTRACTOtINC Washington State Department of Labor & Industries I lel te Espanol L,'ora ;act Safety & Health Claims & Insurance 0 ISearch L&I Page 1 of 2 A -Z Index Help My L&1 Workplace Rights Trades & Licensing HAWK BUILDING CONTRACTORS INC Owner or tradesperson Principals ADKINS, SAMUEL ALAN, PRESIDENT ADKINS, DAYLE, PRESIDENT (End: 01/12/2010) Doing business as HAWK BUILDING CONTRACTORS INC WA UBI No 601 822 387 PO BOX 996 FERNDALE, WA 98248 425-402-1818 WHATCOM County Business type Corporation Governing persons SAM A ADKINS DAYLE ADKINS; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HAWKBCI034PM Effective — expiration 10/14/1997— 05/29/2020 Bond DEVELOPERS SURETY & INDEM CO Bond account no 445499C Received by L8il 10/12/2001 Insurance Ohio Cas Ins Co Policy no. 55306837 Received by L8,1 08/24/2017 Insurance history Savings Active. Meets current requirements. $12,000.00 Effective Jate 10/10/2001 Expiration date Until Canceled $1,000,000.00 Effective date 10/10/2013 Expiration date 10/10/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601822387&L1C=HAWKBCI034PM&SAW= 5/30/2018 HAWK BUILDING CONTRACTOR INC .�1r No savings accounts during the previous 6 y°5eriod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LW Tax debts ..._........................... No LW tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 901,755-01 ...................... _. . Doing business as HAWK BUILDING CONTRACTORS INC Estimated workers reported Quarter 1 of Year 2018 "1 to 3 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235®Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes .......................... _....................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601822387&LIC=HAWKBCI034PM&SAW= 5/30/2018 2 DRAINAGE FIXTURE UNITS QUANTITY UNITS PER FIXT TOTAL DRAINAGE FU'S EWC 1 (EX) LAV TOTALS PLUMBING SANITARY FLOOR PLAN 1 WATER RISER DIAGRAM 2 3 3 SUPPLY FIXTURE UNITS QUANTITY TOTALS COLD FU'S HOT FU'S REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. I NOTE: Revisions will require a new plan submittal C and may include additional plan review fees. j J FILE COPY Permit No. ?G( 9- QQ(o 7 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: RYA-r► IrD K_INS Date: C -3 0 /5 City of Tukwila BUILDING DIVISION I SEPARATE E PERMIT REQU:RFD FOR: Cladgebbanical DI -Electrical ❑ PP)imbing Vet: ' 3as Piping C,ity of Tukwila E 61I._' 4" t0 DIVISION 4 SHEET NOTES 0 NOTES 1SHOWN. PROVIDE SANITARY PIPING TO NEW PLUMBING FIXTURES AS CONNECT NEW PIPING TO EXISTING SANITARY LINE SERVING THE SPACE. FIELD VERIFY CONNECTION LOCATION, INVERT, AND DIRECTION OF FLOW PRIOR TO BID. 2 PROVIDE NEW DOMESTIC WATER DISTRIBUTION PIPING AS SHOWN. T.G.0 SHALL FIELD VERIFY EXISTING SYSTEM LOCATION, CONDITION AND MAKE REPAIRS OR REPLACE AS NEEDED. FIXTURES SHALL CONNECT TO EXISTING SYSTEM SERVING RESTROOM. COORDINATE ALL METER REQUIREMENTS & LOCATION WITH LANDLORD AS NEEDED. 3 PROVIDE NEW VENT PIPING AS NEEDED FOR NEW FIXTURE LOCATIONS. CONNECT TO EXISTING VENT PIPING SYSTEM SERVING EXISTING RESTROOM. FIELD VERIFY CONNECTION LOCATION PRIOR TO BID. IF NO VENT PIPING SYSTEM IS PRESENT PROVIDE NEW 3" VENT THRU ROOF. 4 EXISTING TO REMAIN, NOT PART OF SCOPE. 5 PROVIDE NEW SHELF MOUNTED ELECTRIC WATER HEATER. PIPE PRESSURE RELIEF VALVE TO MOP SINK. SEE DETAIL, SHEET P501. 6 TGC SHALL INSPECT ENTIRE PLUMBING SYSTEM AND PROVIDE SERVICE AND/OR REPAIRS AS REQUIRED TO ENSURE PROPER, DEPENDABLE OPERATION. THE EXISTING FIXTURES TO BE REUSED SHALL BE DISINFECTED, CLEANED AND/OR REFURBISHED TO THE TENANT'S SATISFACTION. REFER TO ARCHITECTURAL DRAWINGS FOR ANY ADJUSTMENTS THAT MAY BE REQUIRED TO COMPLY WITH CODE ISSUES. PLUMBING FIXTURE DATA SINK - "ELKAY" GECR25213, SELF RIMMING, 20 GA 304 SS, 25"x21 1/4, 5 3/8 DEEP, 3 HOLES, 4" O.C. PROVIDE WITH PEERLESS MODEL P299568LF FAUCET (1.8 GPM). PROVIDE "POWERS" E480 THERMOSTATIC MIXING VALVE (ASSE 1070, CSA B125.3 CERTIFIED). SET MAX. TEMP. TO 100° F. WH ELECTRIC WATER HEATER - A.O. SMITH "PROMAX" MODEL #EJSC-10, 10 GALLON, 120/10, 1650W ELEMENT, 18" TALL, 16" DIA., 3/4" INLET/OUTLET, 45 LBS. US UTILITY SINK - FLORESTONE #SC UTILITY WITH "CHICAGO FAUCET" #911-IS369CP LEVER HANDLES. RCF FAUCET WITH 892-GABCP ELEVATED VACUUM BREAKER. EWC ELECTRIC WATER COOLER - ELKAY MODEL EZSTL8C, BARRIER FREE, 8 GALLONS PER HOUR, 1/4 H.P., 115/1/60, 4.6 FLA. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 042018 City of Tukwila BUILDING DIVISION RECEIVED APR 2 5 2018 TUKWILA PUBLIC WORKS PIPING MATERIALS HE C;E l -V. .J CITY OF 1'UKW' LA cb'L^ . 3 f!tJ1U PERMIT CENTER SANITARY (BELOW GRADE) - PVC SCHEDULE 40 OR SERVICE WEIGHT CAST IRON. JOINING - SOLVENT WELDED ASTM D2564 WATER PIPING (ABOVE GRADE) - ASTM B88, TYPE L HARD DRAWN COPPER. JOINING - ANSI/ASTM B32, "LEAD-FREE" SOLDER INSULATION - 3/4" OR LESS, 1/2" THICK FIBERGLASS, 1" OR MORE, 1" FIBERGLASS CONDENSATE PIPING (WHERE REQUIRED) - ASTM B306, COPPER. JOINING - SOLDER GRADE 50B INSULATION -1/2" THICK ARMAFLEX THREADED ON PIPE GENERAL NOTES A. CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND VERIFY ALL WORKING CONDITIONS, CLEARANCES, AND REQUIREMENTS FOR PROVIDING A COMPLETE AND FUNCTIONAL SYSTEM. NO CHANGES IN THE CONTRACT OR CONTRACT SUM WILL BE MADE DUE TO THE FAILURE TO THOROUGHLY EXAMINE THE SITE AND CONDITIONS. B. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAWCUTTING REQUIRED FOR THIS JOB. COORDINATE BACKFILLING AND CONCRETE PATCHING RESPONSIBILITIES WITH THE GENERAL CONTRACTOR. WHEN REQUIRED, IT IS THE OWNER'S RESPONSIBILITY TO CONTRACT WITH A COMMISSIONING AUTHORITY TO COMPLY WITH LOCAL CODES. 4 T • •Mobile 12920 SE 38th STREET BELLEVUE, WA 98006 www.t-mobile.com COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work' under sec. 102 of the copyright act, 17 U.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. AAD:FITCH. Inc. CONSULTING ENGINEER: n 15435 North Scottsdale Rd. S"M4195 Scottsdale. Arizona 85254 T.1 480 888 4200 F41 480 0087223 womlirral.sern DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. 11 SUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 1 F 817.251.8411 DESCRIPTION DATE 0O Co CO z 0 0 z FLOOR PLA PLU BING MDC CORPORATE - RELO 449 CONSTRUCTION ORA DATE: SCALE: DRAWN BY: PROJECT No.: SHEET: 101 04.16.2018 1/4"=1'-0" SC 320108545 1 2 3 4 NOTE: 1. FIRST 8'-0" OF OUTLET PIPING TO BE INSULATED. 2. ALL HEAT TRACED OR EXTERNALLY HEATED PIPING TO BE INSULATED. HEAT TRAP (TYPICAL) CHECK VALVE (TYPICAL) DHW PIPING TO FIXTURES AS SHOWN ON PLANS. DCW SUPPLY TO ` WATER HEATER. BALL VALVE (TYPICAL) THERMOMETER PROVIDE PIPE UNION, DIELECTRICIF REQUIRED FOR DISSIMILARMETALS (TYPICAL). PROVIDE ASME TEMPERATURE AND PRESSURE RELIEF VALVE RATED AT 210°F/150 PSIG. WATTS NO. 100XL-4-125. ELECTRIC WATER HEATER. REFERTO SPECIFICATIONS AND SCHEDULE. SET WATER HEATER ON SHELF ABOVE UTILITY SINK. DRAIN VALVE BY WATER HEATER MANUFACTURER. OATEY 34152 22" DIAMETER ALUMINUM DRAIN PAN WITH 1" CPVC DRAIN FITTING L 3 1/2" MIN. 0 L_J 0 0 L DHW DCW 3/4" 1" REVIEWED FOR CODE COMPLIANCE APPROVED MAY 042018 City of Tukwila BUILDING DIVISION THERMOSTATIC MIXING VALVE. SET DISCHARGE TEMPERATURE TO 110". PIPE HANGER WITHIN 3" OF ELBOW. AUTOMATIC VACUUM RELIEF VALVE (WHEN REQUIRED). PROVIDE PIPE UNION, DIELECTRIC IF REQUIRED FOR DISSIMILAR METALS. RECEIVED CITY OF TUKWILA j\1',' 't 2 3 in f2013 PERMIT CENTER WELDED STEEL EXPANSION TANK WITH POLYPROPYLENE LINING, FDA APPROVED FOR DOMESTIC WATER SERVICE. PRECHARGE TANK TO MATCH WATER PRESSURE AS PER TANK MANUFACTURER. EXPANSION TANK TO BE AMTROL NO. ST-5 WITH UNION CONNECTION. BUTYL DIAPHRAGM PROVIDE HARD COPPER DRAIN FOR T&PIDRAIN PAN OUTLET. ROUTE DISCHARGE LINES FULL SIZE TO SERVICE SINK COMPLETE WITH MINIMUM 2" AIR GAP. STEEL TONIC STRAP SHALL BE 2" WIDE 22 GAUGE SHEET METAL, FASTEN TO WALL W/ (2)1/4" DIA. x 2" SCREWS AT EACH END. PROVIDE BLOCKING IN WALL. SET TANK AS CLOSE TO WALL AS POSSIBLE. PROVIDE WOOD BLOCKS FOR SPACERS BETWEEN WALL AND WATER HEATER. REFER TO SPECIFICATIONS, SCHEDULES AND NOTES FOR ADDITIONAL INFORMATION. PIPING ARRANGEMENT SHOWN IS SCHEMATIC. VERIFY ALL CONNECTION SIZES AND LOCATIONS PER MANUFACTURERS REQUIREMENTS. ADJUST TO SUIT FIELD CONDITIONS. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION OF EXPANSION TANK. REFER TO FLOOR PLANS FOR PIPE SIZES. PROVIDE SEISMIC STRAP OR BRACING, HEAT TRAP AND AUTOMATIC VACUUM RELIEF VALVE WHEN REQUIRED BY LOCAL AUTHORITIES. (A3 ELECTRIC DOMESTIC WATER HEATER NTS 12920 SE 38th STREET BELLEVUE, WA 98006 www.t-mobile.com COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 U.S.C. As amended January 2003. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. AAD:FITCH . Inc. 16435 North Scottsdale Rd. Suila 195 Scollsdalo, Arizona 85254 T*1 480 988 4200 F*1 480 998 7223 vnwcinnell.corn CONSULTING ENGINEER: DON PENN CONSULTING ENGINEER 1301 SOLANA BLVD. BLDG. IISUITE 1420 WESTLAKE, TX 76262 O 817.410.2858 I F 817.251.6411 At DESCRIPTION DATE rJ J Q F- J � • z WW (I) z= W O D41.14. O c36 D U)oft) UJI— co 00 O.; 0) z 0 H z BING DETAILS MDC CORPORATE - RELO CONSTRUCTION`, DRAWINGS DATE: SCALE: DRAWN BY: PROJECT No.: SHEET: P501 04.16.2018 NO SCALE SC 320108545 1 2 3 4