Loading...
HomeMy WebLinkAboutPermit PG18-0067 - FLOOR & DECOR - OVERFLOW SYSTEM TO ROOFFLOOR & DECOR 17651 SOUTHCENTER PKWY PGI 8-0067 Parcel No: Address: City of Tukwila t of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwlla, Washington 98188 Phone: 206~431'3670 Inspection Request Line: J06'438'935D Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 3523049088 17651 SOUTHCENTER PKWY Project Name: FLOOR & DECOR Permit Number: PGI8-0067 Issue Date: 5/18/2018 Permit Expires On: 11/14/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: 180 N STETSON AVE #324-D , CHICAGO, WA, 80601 MICHAEL MOORE l765lSOUTHCENTERPKWY ' TUKWILA, WA, 98188 HORIZON RETAILCONSTRUCTION INC l}0OHORIZON DR,STURTEVANT'WI, 53177 HOm|ZR[072N5 ''' Phone: (970) 308-7820 Phone: (262) 638-600 Expiration Date: 4/15/2019 DESCRIPTION OF WORK: PROVIDE OVERFLOW SYSTEM TO ROOF Valuation ufWork: $100000.00 Water District: HIGHLINE Sewer District: TUKWILA Fees Collected: $190.52 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 20152017 Permit Center Authorized Signature:Viikkhl fi4/b) Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: /`` iC Date: • This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL e 8005 ROUGH -IN PLUMBING CITY OF TUKWI Community Development epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/./www.TukwilaWA.gov PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 47 V/ Suite Number: Floor: Tenant Name: f crr✓ New Tenant: ❑ Yes ❑..No PROPERTY OWNER Name: i0, .4,44:-/ , as e_4,-- cyAddress: Address:/ 7 6 :,—/ rfa cam,,, p4 c3.. 447 Name: Phone6 Fax: 7‘..,„ 4, f-7 eau Address: City: State: Zip: CONTACT PERSON —perste rr wing all prc t eo munication Name: i0, .4,44:-/ , as e_4,-- cyAddress: Address:/ 7 6 :,—/ rfa cam,,, p4 c3.. 447 City:��tw ,/, State: (Al} Zip 408.3 Phone6 Fax: 7‘..,„ 4, f-7 eau // Emaili7: /%/77 C re- v tec , /e.,„ dd. coom PLUMBING CONTRA R INFORMATION Company Name: ____r --go Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ l cam. 1-1 Scope of Work (please provide detailed information): �'�''� Jec" 0 L'271 d tJ •1' Building Use (per Int'I Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: H:Wpplications\Forms-Applications On Linek2011 Applications\Plumbing Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 rik\ Indicate type of plumbing fixtures and/or geepiping outlets being installed and the quantity ow: Fixture Type J Qty 1111 Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Repair or alteration of water piping and/or water treatment equipment 3 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type I Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signatur Print Name: Mailing Address: / 7 G '"f , 'v ems) �^- Date: .f /1 Day Telephone: H: Applications\Fonns-Applications On Line\201 1 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh City JA State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $190.52 PG18-0067 Address: 17651 SOUTHCENTER PKWY Apn: 3523049088 $190.52 Credit Card Fee $5.55 Credit Card Fee I R000.369.908.00.00 0.00 $5.55 PLUMBING $177.86 PERMIT FEE R000.322.100.00.00 0.00 $109.14 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $35.57 TECHNOLOGY FEE $7.11 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14416 R000.322.900.04.00 0.00 $7.11 $190.52 Date Paid: Friday, May 04, 2018 Paid By: DAN PRINCE -HORIZON Pay Method: CREDIT CARD 027400 Printed: Friday, May 04, 2018 10:15 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: v i e j� c k/CC.c T of Inspec ion: ' rl—kor1 1 #" 1 LC L. Address: 17195I Sccn�ear k' Hwy x&41 Date Called: Special Instructions: Wanted:/ C Date r 5.201 lSl � a.m. P.m. Requester: Phone No: Corrections required prior to approval. yl Approved per applicable codes. COMMENTS: (R-lotA"vtio 1-6 Inspector`, Date:/ / 2.0` REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje yzehr ir jjeco TYpp I� :;tion•l/ .� Address:65 Date Called: �/ cpea edittcniee Special Instructions: . Date Wanted: 6-V . p.m. Requester: Phone No: plApproved per applicable codes. COMMENTS: P6.1_42A "t/Corrections required prior to approval. ala_;4' zebi/c.0 coe Ppititt-7 roffscLrilrs Cion 3ib�. inspector: gOe_ Date: /„` 10,e REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit P6I?-017 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /7S/ iS-AAAPair-feraka/ 'T.) of Inspection: t<t) i PLACil IA Addr ss: I . lle .r- - d PA. • , I 4 ..lam....., Special Instructions: ROO F ii/C+- i Date Wanted: a. , Requester: Phone No: 01 Approved per applicable codes. I:0 Corrections required prior to approval. COMMENTS: l<0 vt-f" XX.) 13Z-tit-kJ1 {:\--p7t-2 ) AC/ k Inspector: Date:6 2,4 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0067 DATE: 05/08/18 PROJECT NAME: Floor Decor SITE ADDRESS: 17651 Southcenter X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: fit, -S Building Division t1 L --)1-o Public Works 111 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/09/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/05/18 9rT, Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 HORIZON RETAIL CONST INC c I Ionic Espanol Contact: Safety & Health Claims & Insurance 0Washington State Department of Labor & Industries Search L&I A-7, Index Help Page 1 of 3 My Workplace Rights Trades & Licensing HORIZON RETAIL CONST INC Owner or tradesperson Principals HENDERSEN, JON E GUSTIN, ROBERT L HENDERSON, JON E JAWORT, DAN, AGENT Doing business as HORIZON RETAIL CONST INC WA UBI No 601 483 044 1500 HORIZON DRIVE STURTEVANT, WI 53177 262-638-6000 Business type Corporation Governing persons ROBERT L GUSTIN JON E HENDERSEN; PATRICK J CHRISTENSEN; PAT CHRISTENSON; JON E HENDERSEN; ERIC NIEDEFFER; TOM SCHAEFER; DAN SIUDAK; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HORIZRC072N5 Effective — expiration 08/25/1993— 04/15/2019 Bond HANOVER INS CO Bond account no. 1592447 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/15/2002 04/10/2002 Expiration date Until Canceled Insurance Zurich American Ins Co $1,000,000.00 Policy no. 5919211 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601483044&LIC=HORIZRC072N5&SAW= 5/18/2018 HORIZON RETAIL CONST INC Received by L&I Effective date 03/13/2018 03/29/2018 Expiration date 03/29/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L81 Tax debts No L81 tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. NJONB01457 Issue date 10/02/2017 Violation city STURTEVANT Type of violation CONSTRUCTION INFRACTION Description Subcontracting to or using an unregistered contractor. Satisfied RCVV/VVAC 18.27.200(1)(e) RCW Violation amount $1,000.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L8I Account ID 861,958-00 Doing business as HORIZON RETAIL CONSTRUCTION Estimated workers reported Quarter 1 of Year 2018 "4 to 6 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@lawa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes This contractor received a valid strike(s) for violation or infraction for the following L&I law(s). Learn more about contractor strikes. RCW Violation 18.27.200 Description Failure to comply with contractor registration requirements, per RCW 18.27 Contractors not allowed to bid No debarments have been issued against this contractor. Effective Date 9/24/2009 Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/06/2018 Inspection no 317948086 Location 17261 Southcenter parkway Tukwila, WA 98188 No violations Page 2 of 3 Help us improve https://secureini.wa.gov/verify/Detail.aspx?UBI=601483044&LIC=HORIZRC072N5&SAW= 5/18/2018 HORIZON RETAIL CONST INC Page 3 of 3 Washington Slate Dept. of Labor & Industries. Use of this site is subject to the laws of the slate ot VVashington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601483044&LIC=HORIZRC072N5&SAW— 5/18/2018 27'-4" SM-20N ACROVYN 4000 WALL CONDRION SPECIFIED FASTENER DRILL DIAMETERS C/S PART NUMBER WALL RETAINER STEELSTUD/GYPSUM WALL WOOD STUD/GYPSUM WALL #6 X 1 5/8' BUGLE HEAD SHEET METAL SCREW N/A 1/8' 90H079002 CONCRETE/CONCREfE BLOCK AF{ PLASTIC ANCHOR #10 X 1 12' PHI WPS PAN HEAD SMS 1/4' 9/32' 90H039004 90H189002 CONCRETE/CONCRETE BLOCK END CAP ATTACHMENT 1/8' BUND RIVET #8 SAE FLAT WASHER STEEL PLATED N/A 5/32' 90H111002 90H010003 STEEL STUD (BY OTHERS) G.W.B. --{ (BY OTHERS) 3" [76.1mm] 3/8" [9.5mm] REGRIND RETAINER (24U026000) #6 X 1 5/8" BUGLE HD SMS 18" [457.2mm] MAX. ACROVYN 4000 COVER (24U002xxx) ACROVYN CHAMELEON (24U634xxx) R 1 /4" [R6.4mm] Apri CORNER GUARD DETAIL SCALE: NTS CEILING 1/4" [6.4mm] CAP TOP & BOTTOM �I FLOOR 1/16" _ [1.6mm] TOP & BOTTOM 0= t- BASE HGT. 336'-11 " FLOOR PLAN LEGEND EXISTING WALL NEW MASONRY WALUINFILL NEW STUD WALL j/7//////. NEW LOW STUD WALL FLOOR PLAN GENERAL NOTES 1. CURING AND HARDENER- SEE SPECIFICATIONS FOR CURING PROCEDURE AND MATERIALS REQUIRED FOR CURING AND HARDENING OF INTERIOR AND EXTERIOR CONCRETE SLABS. 2. CONCRETE SLAB JOINTS- SEE STRUCTURAL DRAWINGS FOR TYPICAL CONCRETE SLAB JOINT LOCATIONS, REINFORCING AND DETAILS FOR THE FOLLOWING: A. ENTRY VESTIBULE B. TRUCK WELL C. SIDEWALK 3. MISCELLANEOUS WOOD BLOCKING- G.C. SHALL PROVIDE ALL NECESSARY F.R.T.WOOD BLOCKING OR METAL F.R.T. STUD BLOCKING FOR ALL WALL SUPPORTED DEVICES, I.E. ACCESSORIES, PANELS, EQUIPMENT ETC PER THE DEVICE MANUFACTURER'S RECOMMENDATIONS. 4. BUILDING SERVICES AND EQUIPMENT UTILITY DROPS- THE LOCATIONS OF ALL UTILITY DROPS INCLUDING FIRE, ELECTRICAL, PLUMBING ETC. MUST BE WITHIN 18" OF OF DOOR OPENINGS ON PERIMETER ALLS INSIDE THE BUILDING. NO LOCATIONS OF UTILITY DROPS WILL BE ACCEPTED OUTSIDE OF THESE AREAS BEFORE RACK SYSTEM INSTALLATION. 5. EXTERIOR AND INTERIOR PIPE BOLLARDS TO HAVE RED COVERS. POLYPROPYLENE COVERS BY -IDEAL SHIELD 6. THE GENERAL CONTRACTOR MUST VERIFY WITH FINAL FIXTURE PLAN BEFORE BUILDING INTERIOR PARTITIONS. FLOOR PLAN KEYED NOTES 0 O O O YELLOW LOADING ZONE STRIPING w/ RED NO PARKING LETTERING 60'W x 36" D x 60"H PROPANE STORAGE CAGE (BY OTHERS) 6" DIAMETER CONCRETE FILLED STEEL PIPE BOLLARD TYPICAL AT SIDES AND REAR OF BUILDING - REFER TO DETAIL 3/A504 NOT USED. EXISTING STEEL COLUMN, TYPICAL - PAINT PER DETAIL 1/A800 0 EXISTING INTERNAL 6" ROOF DRAIN - G.C. TO FIELD VERIFY. i i 46'-11i" 43'-0" WAREHOUSE 103 i 43'-0" i 43'-0" 43'-0" 47'-0" FLOR&DE 88784 (E ISTI G 86337 S.F. ofi TENANT FLOOR PLAN SCALE: 1/16" = 1'-0" A: LE A NOTE: REFERENCE SPECIFICATIONS SECTION 03 35 00 "POLISHED CONCRETE" FOR DESIGN MIX NORTH i 43'-72' i 12 13 NEW INTERIOR DOWNSPOUT - REFER TO SHEET A301. CONCRETE PAD AT EXTERIOR DOORS NEW GAS METER LOCATION. SEE CIVIL AND PLUMBING PLANS. 42" HIGH HANDRAIL - SEE DETAIL 2/A504 TRENCH DRAIN AT TRUCK WELL - SEE CIVIL FOR DETAILS TRANSFORMER - SEE CIVIL AND ELECTRICAL. COORDINATE TRANSFORMER PAD REQUIREMENTS AND PRIMARY CONDUIT INSTALLATION WITH UTILITY PROVIDERS'S STANDARD DETAILS. DOMESTIC AND FIRE RISERS - SEE CIVIL FOR UTILITY ROUTING. PROVIDE DETECTOR CHECK VALVES PER LOCAL UTILITY REQUIREMENTS. COORDINATE SIAMESE AND PIV LOCATIONS WITH LOCAL FIRE DEPARTMENT. FLUSH CURB CONDITION - SEE CIVIL O 6" THICK REINFORCED CUSTOMER LOAD -OUT SLAB - SEE CIVIL AND STRUCTURAL FOR SLAB EDGE CONDITIONS AND REINFORCEMENT. O 6" REINFORCED CONCRETE TRUCK WELL SLAB - SEE CIVIL AND STRUCTURAL FOR SLAB EDGE CONDITIONS AND REINFORCEMENT. 17 NOT USED. 18, COMPACTOR CHUTE AND CONTAINER BY FLOOR AND DECOR VENDOR. COORDINATE ELECTRICAL REQUIREMENTS . 0 NOT USED. 20 8" REINFORCED COMPACTOR SLAB. SEE CIVIL FOR IDEAL SLOPE AND STRUCTURAL FOR SLAB EDGE CONDITIONS, AND REINFORCEMENT. 21 6" REINFORCED CONCRETE SLAB - SEE STRUCTURAL FOR REINFORCEMENT 22 NOT USED. 0 EXTERIOR ANGLE AT LOADING DOCK WALL. 0 NEW EGRESS DOOR WITH METAL STAIRS, RAILING AND NEW LANDING. O EXISTING EGRESS DOOR TO REMAIN. O WALL INFILL STRUCTURE. RE: STRUCTURAL & FIRE PROTECTION O NEW VESTIBULE/ENTRY CENTERED ON EXISTING STRUCTURAL PILASTERS AT THIS LOCATION. 28 8" STEEL STUD WALL, TO HIDE NEW PLATE AT BOTTOM. 29 EX. 8" STORM DRAIN LINE FROM EX. 6" ROOF DRAIN LEADERS, TO U.G. STORM DRAIN SYSTEM. SEPARATE PERMIT REQUIRED FOR: Cly id Tv nbgn ��.CIVEKM REVISIONS ---t o than s4a41 rrade to thP► no of t*irl�Y'7#i*f . T1..oC approval ;A :ta Biiildino Division. It) -.-;..3'3-1S will require a new R! submittal and may inc:ude additional plan review fees. FILE COPY Permit No. PG) l P— 00(07 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt o, improved Fold Copy and conditions is acknowledged: 8y: Data: 2'-' (i - I b City of Tukwila BUILDING DIVISION 1/A502 1/A501 10'-102" 12'-5" 4-HB 0 DESIGN BUILD RM 118 144 SQFT • ABOVE JANITOR 107 115 SQFT — I WOMENS 106 221 SQFT pR r 1 DATA 116 64 SQFT CORRIDOR 1 108 o; o 0 le (I;o ®D 0 0 MENS 105 223 SQFT :o 0 . 4 FD VEND. 0 VEND. `ypl/Np�y BREAK ROOM 109 383 SQFT ASSIST. ROOM 114 103 SQFT CEM 115 141 SQFT C REVIEWED FOR )DE COMPLIANCE APPROVED MAY 16 2018 1A/Z City of Tukwila BUILDING DIVISION TRAINING 110 244 SQFT CV • SIN U CORRIDOR 2 111 0 z 0 23'-42' 4" O ENLARGED OFFICE FLOOR PLAN SCALE: 3/16" = 1-0 0 0 lk \ NORTH SAKE REINDERSMA ARCHITECT 5450 E. High Street, Suite 200 Scottsdale, Arizona 85054 p: 480.515.5123 f: 602.513.7193 www.sra360.com AKE H. REINDERSMA STATE OF WASHINGTON 0 U S- Q a) E U 0 0 0 cE E SI £La I I a. RECEIV a) MAY 08 2 0 W co I— co wErov; 00 0) W = D 06 0 < 0�� 0Lc.� ED 018 TUKWILA PUBLIC WORKS RECEIVED ITV OF TUKWILA MAY 0 Ia 2018 PERMIT CENTER E 0 a) date: 05/3/2015 issued for: FOR PERMIT revision date: no.: OWNER REVISION 08-28-17 /2 \ GIN CORR 05-3-I5 job no.: 17-027 sheet title: FLOOR PLAN 3/A201 I 8" PVC OVERFLOW DRAIN LINE AT 2% (TYP.) 4/A201 ROOF SLOPE 8" PVC OVERFLOW DRAIN LINE AT 2% (TYP.) H VAC SETBACK, TYP ROOF PLAN SCALE: 1/16" = 1'-0" ENLARGED MAPES ROOF PLAN @ ENTRY SCALE: 1/4" = 1'-0" SLOPE RIDGE RIDGE 8" PVC OVERFLOW DRAIN LINE AT 2% (TYP.) -•14 PIPE FLOW DRECTION NORTH NORTH 2/A201 ±79'-11" 8" PVC OVERFOW DRAIN LINE AT2%(TYP.) f T RIDGE ROOF SLOPE ROOF SLOPE RIDGE 8" PVC OVE FLOW DRAIN LINE AT 2% (TYP.) - — — — — PIPE FLOW DIRECTION 8/A304 CANOPY BY VENDOR — UNDER SEPARATE PERMIT 8" PVC OVERFLOW DRAIN LINE AT 2% (TYP.) ROOF SLOPE ROOF SLOPE 8" PVC OVERFLOW DRAIN LINE AT 2% (TYP.) HVAC SETBACK, TYP ///////</ ROOF PLAN KEYED NOTES NEW 60 MIL. TPO ROOF (MECHANICALLY FASTENED) MIN. R-23 AGED POLISOCYANURATE ROOF INSULATION ON EXISTING PLYWOOD DECK BY G.C.. NEW 60 MIL. TPO ROOF (MECHANICALLY FASTENED) MIN. R-23 AGED POLISOCYANURATE ROOF INSULATION ON NEW 1-1/2" METAL DECK BY G.C. RECOVERY BOARD W/ TPO OVER METAL DECK - BY G.C. EXTERIOR CANOPY UNDER SEPARATE PERMIT. COORDINATE WITH ARCHITECT. PREFINISHED GUTTER AND DOWNSPOUTS, REFER TO PLUMBING. GUTTER AND PIPING BY G.C., REFER TO PLUMBING. NEW ROOF TOP MOUNTED HVAC EQUIPMENT INSTALLED BY G.C,. COORDINATE W/ STRUCTURAL AND MECHANICAL FOR INSTALLATION OF CURB ADAPTER WHERE OCCURS. SEE STRUCTURAL FOR ADDITIONAL FRAMING SUPPORT AT CURBS. NEW 30" ROOF HATCH W/ SAFETY POST AND LADDER, BY G.C., SEE 9/A503. DASHED LINE INDICATES EXISTING DEMISING WALL BELOW. EXISTING ROOF DRAINS WITH INTERIOR LEADER PIPE ATTACHED TO COLUMNS TO U.G. STORM DRAIN -TO BE RE -USED. NEW VENT THRU ROOF, V.I.F., SEE PLUMBING NEW FLUE TO ROOF VENT CAP V.I.F., SEE PLUMBING 13 SMOKE AND HEAT VENTS BY G.C., RE: 12/A202. SEE HPS SHEET FOR HIGH PILE ANALYSIS, LOCATIONS AND SMOKE/HEAT VENT CALCULATIONS. PROTECTIVE WALK PAD BY G.C. - PROVIDE ROOF MFG'S STANDARD FULLY ADHERED WALK PADS IN LOCATIONS SHOWN - WALK PAD WIDTH TO BE DOUBLE ON SERVICE SIDE OF HVAC UNIT. DOCK CANOPY. SEE SHEET 10/A504. 16 ADD OVERFLOW DRAIN, PER DETAIL 1/A202, AND 8" SEPARATE PIPE TO DAYLIGHT PIPE TO OUTSIDE OF BUILDING PER DETAIL 4/A201. ROOF DRAIN CALC ROOF TRIBUTARY AREA PER (3) OVERFLOW DRAINS = 44,392 SF MANNING FORMULA: 1.2"/hr (25 YR STORM) x 0.8 RUNOFF x 44,392 / 43,560 = 0.978 c.f.s REQUIRED: 0.978 c.f.s. = 7.1 sq. in. @ 2% SLOPE PROVIDED: 8" PIPE = 25.14 sq. in. AL MATCH EXISTING TIO PANEL TBD NEW JOIST BEARING EMBEDS, REFER TO STRUCTURAL DRAWINGS. NEW ROOF OVER AL 18'-0" AFF NEW DOCK PAINT LINE / REVEAL • NEW ROOF OVER NEW CANOPY AT PRO SALES. ROOF KEY PLAN SCALE: 1/4" = 1'-0" PIPE GUARD AND CONNECTIONS PER MANUFACTURE DOWNSPOUT AND STRAP WALL PER PLAN STEEL PIPE GUARD BEACON (BPGWM636-Y) AT REAR WALL, POWDER COATED YELLOW - SEE ELEVATIONS FOR LOCATIONS INSTALL PER MANUFACTURES RECOMMENDATIONS. DOWNSPOUT DOWNSPOUT AND CLEAN -OUT SEE CIVIL FOR CONTINUATION OF DRAIN IF REQUIRED PLAN VIEW ELEVATION VIEW DOWNSPOUT DETAILS SCALE: 1/2" = 1'-0" ROOF PLAN GENL NOTES 1. REFER TO ROOF SYSTEM MANUFACTURER'S WRITTEN INSTRUCTIONS FOR INSTALLATION OF A COMPLETE ROOF SYSTEM. 2. GENERAL CONTRACTOR TO COMPLY WITH ALL OCCUPATIONAL, HEALTH AND SAFETY REGULATIONS REQUIRED BY OSHA OR EQUIVALENT APPLICABLE CODES. ANY CONSTRUCTION REQUIRED TO MEET ABOVE STATED REGULATIONS SHALL NOT COMPROMISE ROOF WARRANTY. 3. ALL GAS PIPING ON ROOF SHALL BE PAINTED (SAFETY YELLOW) 2 COATS OF ENAMEL. 4. ROOF TOP EQUIPMENT LOCATIONS- VERIFY SIZE OF OPENINGS AND LOCATION OF ALL ROOF TOP MOUNTED HVAC EQUIPMENT WITH MECHANICAL, ELECTRICAL , PLUMBING AND STRUCTURAL REQUIREMENTS AND DETAILS. 5. TAPERED CRICKETS- PROVIDE TAPERED ROOF INSULATION AT ALL HAVC UNITS AND ROOF SCUTTLE TO PROVIDE PROPER DRAINAGE ROUTING AT EACH LOCATION. 6. ROOF PENETRATIONS- SEE DETAILS ON SHEET A202 FOR TYPICAL ROOF PENETRATIONS FOR ELECTRICAL, GAS AND PLUMBING PIPING. 7. FLUE AND VENT DETAILS- SEE DETAILS ON SHEET A202 FOR TYPICAL ROOF PENETRATIONS FOR FLUE AND VENT PIPE PENETRATIONS. 8. COORDINATE ROOF ELEVATIONS WITH STRUCTURAL DRAWINGS. REFER TO SPECIFICATIONS FOR ROOF WARRANTIES, CURBS, FLASHING DETAILS, ETC. 9. THE ROOF SHALL NOT BE USED FOR STOCKPILING OF EQUIPMENT OR MATERIALS UNLESS APPROVED IN WRITING BY ARCHITECT AND STRUCTURAL ENGINEER. 10. REMOVE ROOF WASTE, EMPTY ADHESIVE CONTAINERS, AND OTHER DEBRIS ON A DAILY BASIS. 11. CONDENSATE PIPING AND GAS PIPING SHALL BE SECURED TO ROOF WITH PRE - MANUFACTURED SUPPORTS WITH ADDITIONAL ROOF MEMBRANE REINFORCEMENT AT EACH SUPPORT LOCATION. 3/A201 10'-0" AFF PAINT LINE I REVEAL NEW DOWNSPOUT NOZZLE: JOSAM #25010-BS OR APPROVED EQUAL, AS REQUIRED RE: CIVIL FOR. DOWNSPOUT TO DAYLIGHT LOCATION. RE: PLUMBING FOR REQUIRED SIZE OF DOWNSPOUT NOZZLE IF USED AL 0'-0" AFF FINISH FLOOR NEW BACKFILL RE: CIVIL ROOF MEMBRANE OVER BONDING ADHESIVE - EXTEND UP OVER BLOCKING AT TOP OF PARAPET. CANT STRIP, SEE DETAIL 4/A202 ROOF MEMBRANE OVER RIGID INSULATION (MIN. R-23) OVER STEEL DECK. REFER TO NOTES ON A201 ROOF DRAIN SUMP RE: PLUMBING STEEL JOIST, REFER TO STRUCTURAL DRAWINGS ROOF DRAIN LEADERS: SEE PLAN, DRAINS AND 8" OVERFLOW MAY BE AWAY FROM PARAPET DOWNSPOUT, SIZE TO WRAP DRAIN LEADERS, PREFINISHED TO MATCH WALL. RE: PLUMBING FOR REQUIRED SIZE 7 1/4" CONCRETE PANEL REFER TO STRUCTURAL DRAWINGS. STEEL DOWNSPOUT GUARD AT EACH DOWNSPOUT ATTACH W/ EXPANSION BOLTS (BEACON BPGWM636-Y) 3/A201 NEW 6" CONCRETE SLAB, REFER TO STRUCTURAL DRAWINGS NEW I-OUNDAI ION, FOOTING, AND BACKFILL RE: STRUCTURAL; RE: CIVIL REVIEWED FOR CODE COMPLIANCE APPROVED MAY 16 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 0 E, 2018 PERMIT CENTER SAKE REINDERSMA ARCHITECT 5450 E. High Street, Suite 200 Scottsdale, Arizona 85054 p: 480.515.5123 f: 602.513.7193 www.sra360.com 0 a) U a 11273 SAKE H. REINDERSMA STATE OF WASHINGTON 0 U U7 Q a) E U O 0 a) cn ^' rn gcp to u7 I J c U fi00 c 0 0_ a) date: O5/S/2OI8 issued for: FOR PERMIT revision date: no.: OWNER REVISION 05-25-17 2 CITY GORR 05-5-I8 job no.: 17-027 sheet title: ROOF PLAN sheet no.: EX. ROOF DRAIN STRAINER EDGE OF LEAD FLASHING BEGINNING OF TAPERED ROOF DRAIN SUMP EX. 6" ROOF DRAIN LEADER ENSURE THAT ROOF CURBS ARE LEVEL. NOTE: BASE FLASHINGS SHALL BE TRIMMED FLUSH WITH TOP OF CURB AND SHALL NOT BE ALLOWED TO LAP ONTO TOP OF CURB. COUNTERFLASHING i�:,uww u NEW OVERFLOW DRAIN STRAINER COMPRESSION RING DRAIN BOWL RIGID INSULATION BOARD TREATED WOOD NAILERS - SECURE TO WOOD DECK DECK CLAMP EX. WOOD DECK NEW 8" OVERFLOW LINE TO NEW DRAIN LINE UNDER ROOF TO DAYLIGHT, SEE ROOF PLAN AND DETAIL 4/A201 NOTE: INSTALLATION OF COUNTER FLASHING MUST BE COORDINATED BETWEEN ROOFING CONTRACTOR AND MECHANICAL CONTRACTOR TO INSURE THAT SCREWS USED FOR SECURING COUNTER FLASHING ARE INSTALLED LOW ENOUGH TO INSURE THAT SCREW HEADS WILL NOT INTERFERE WITH RTU FITTINGS ON CURB SCREWS MUST BE INSTALLED BELOW BOTTOM OF RTU TO ALLOW SCREW HEADS TO BE EXPOSED FOR REMOVAL IN THE FUTURE, COUNTER FLASHING SHALL BE INSTALLED AS SOON AS BASE FLASHING ARE INSTALLED. EXHAUST FANNENT/ETC. APPROVED SEALANT, CONTINUOUS, AS REQUIRED CORROSION RESISTANT HEX HEAD SCREWS WITH WEATHERPROOF WASHERS. MINIMUM 2 SCREWS PER SIDE EQUALLY SPACED. FASTENER HEADS AND WASHERS FULLY SEALED WITH APPROVED SEALANT. .040 MILL FINISHED ALUMINUM COUNTERFLASHING HEMMED TO ALLOW COUNTERFLASHING TO SERVE AS TERMINATION BAR AND COUNTERFLASHING FASTENED MAX. 6" O.C. FASTENER HEADS AND WASHERS SHALL BE FULLY SEALED W/ APPROVED SEALANT. FULLY ADHERED SINGLE PLY MEMBRANE BASE FLASHINGS, EXTEND UP OVER CURB /APPROVED SCREWS AND PLATES, TERM BAR, REINFORCED SECUREMENT STRIP OR / OTHER APPROVED METHOD OF SECUREMENT. SINGLE PLY ROOF MEMBRANE ROOF INSULATION PLYWOOD ROOF DECK DETAIL AT EXHAUST FAN/ROOF EQUIPMENT FLASHING SCALE: 1 1/2" 1 0 PROVIDE CONT. BAND OF SEALANT - WIPE OFF EXCESS 6" WIDE JOINT COVER PLATE - CRIMP EDGES OVER BOTTOM OF COPING CAP - PAINT TO MATCH PREFINISHED COPING CAP AND EDGE FLASHING TO MATCH P-4 ISOMETRIC ROOF - TYPICAL COPING JOINT SCALE: NTS PREFINISHED COPING TO MATCH P-4 SNAP LOK COPING - CONT. CLIP ANGLE TERMINATION BAR - SEE MANUFACTURER'S RECOMMENDATIONS WALL PER PLAN TPO CORNER PATCH PER MANUFACTURER'S RECOMMENDATIONS WRAP DOWN MINIMUM OF 1" DOWN FRONT FACE WRAP TPO UP OVER AND DOWN FACE OF PARAPET TPO ROOF SYSTEM CANT STRIP TPO ROOF CORNER PARAPET DETAIL SCALE: NTS 7/A202 MIN 18"' i EMT/RIGID CONDUIT SHALL BE LOCATED MINIMUM 18" FROM PARAPET, SIDE OF CURB, ETC. PARAPET SONNEBORN NP-1 SEALANT APPROVED FASTENERS HEAVY DUTY GALVANIZED CONDUIT BRACKET TO BE SPACED 5' ON CENTER MAXIMUM ELECTRICAL CONDUIT APPROVED FASTENERS SONNEBORN NP-1 SEALANT SINGLE PLY MEMBRANE WALL FLASHING SINGLE PLY MEMBRANE WALL FLASHING APPROVED NON -REINFORCED FLASHING STAINLESS STEEL CLAMP EMT/RIGID CONDUIT APPROVED SEALANT/MASTIC CONDUIT SHALL BE SPACED MINIMUM 18" APART TO ALLOW ADEQUATE SPACE FOR FLASHINGS. PARAPET WALL MOUNTED CONDUIT 1/2" MIN. HOT AIR WELD, TYPICAL PARAPET 1 1.5" TO 2" 1 CONDUIT WALL PENETRATION NOTES: 1. NEW WALL PENETRATIONS FOR ELECTRICAL CONDUIT, ETC. SHALL BE FLASHED UTILIZING MEMBRANE FLASHINGS IN THE SAME MANNER AS F THEY WERE ROOF PENETRATIONS. SEALANT ONLY SHALL NOT BE ACCEPTABLE. 2. NEW ROOF PENETRATIONS FOR ELECTRICAL CONDUIT, ETC., IF REQUIRED, SHALL BE LOCATED MINIMUM 18" FROM PARAPET, CURB, ETC. AND SHALL BE FLASHED UTILIZING PREFORMED MEMBRANE FLASHINGS. PITCH POCKETS SHALL NOT BE ACCEPTABLE. 3. CONDUIT TO BE USED FOR ROOF PENETRATIONS SHALL BE EMT/RIGID CONDUIT. FLEXIBLE CONDUIT SHALL NOT BE ACCEPTABLE FOR ROOF PENETRATIONS. 4. CONDUIT FOR ROOF PENETRATIONS SHALL BE MINIMUM 18" HIGH ABOVE NEW/EXISTING ROOF MEMBRANE. 5. WALL MOUNTED CONDUIT, IF REQUIRED, SHALL BE FASTENED USING HEAVY DUTY GALVANIZED CONDUIT BRACKETS WITH 2 FASTENER PER BRACKET. GALVANIZED CONDUIT BRACKETS SHALL BE SPACED MAXIMUM 5' ON CENTER. PRIOR TO FASTENING CONDUIT BRACKETS, SONNEBORN NP-1 SEALANT SHALL BE APPLIED BETWEEN FASTENING FLANGE ON CONDUIT BRACKETS AND MEMBRANE WALL FLASHING. FASTENER HEADS OF FASTENERS USED FOR SECURING CONDUIT BRACKETS SHALL BE FULLY SEALED WITH NP-1 SEALANT. CONDUIT DETAILS SCALE: 3/4" = 1'-0" WIDTH TO FIT WALL THICKNESS METAL COPING PROFILE CONTINUOUS CAP FLASHING ROOF MEMBRANE CONT CAULK VERTICAL SEAM AT EDGE MITER EXPOSED SIDES AT 45° CONTINUOUS CAP FLASHING STAINLESS STEEL CLAMPING RING ROOF INSULATION SEE SPECS ISOMETRIC APPROVED SEALANT/MASTIC PRE -MOLDED PIPE FLASHING APPROVED FASTENERS AND PLATES PER MANUFACTURER'S REQUIREMENTS HOT AIR WELD SINGLE PLY ROOF MEMBRANE TPO - SMALL PIPE PENETRATION SCALE: 1 1/2" = 1'-0" LINE OF VERTICAL CAP - CUT AS SHOWN. BENT AND LOCATED UNDER ADJACENT CAPS MITER CORNERS (TIGHT) WITH CONT CAULK BEAD LINE OF VERTICAL CAP - CUT AS SHOWN. BENT AND LOCATED UNDER ADJACENT CAPS ADDITIONAL SUPPORT /BRACING BY G.C., SEE STRUCTURAL SAKE REINDERSMA ARCHITECT 5450 E. High Street, Suite 200 Scottsdale, Arizona 85054 p: 480.515.5123 f: 602.513.7193 www.sra360.com Q a) E 0 v C O U a) O Q date: 05/3/20I8 issued for: FOR PERMIT revision no.: date: AOYVNER REVISION 08-25—17 CITY CORR 05-3-18 job no.: 11-021 sheet title: ROOF DETAILS TRANSLUCENT COVER WITH METAL CURB (REFER TO MANUF. SPECIFICATIONS) LATCH ASSEMBLY ROOF MEMBRANE OVER BONDING ADHESIVE ON CURB (REFER TO MANUF. SPECIFICATIONS) MANUAL RELEASE, CONFIRM USE WIT LOCAL FIRE DEPARTMENT ROOF MEMBRANE SEALED LAP JOINT (REFER TO MANUF. SPECIFICATIONS) - ROOF MEMBRANE (REFER TO SPECIFICATIONS) WOOD DECK, TYP EXISTING ROOF FRAMING NYSTROM SMOKE ESCAPE SVLA48x96D1N280R ADDITIONAL SUPPORT /BRACING BY G.C., SEE STRUCTURAL INSIDE MANUAL RELEASE HEAT & SMOKE VENT DETAIL APPROVED SEALANT/MASTIC HOT AIR WELD APPROVED FASTENER AND PLATES /— STAINLESS STEEL I` CLAMPING RING APPROVED NON - REINFORCED FLASHIN 1/2" MIN. 12" MAX. —1" MIN. CURB SCHEDULE INSULATION THICKNESS CURB HEIGHT 3" RIGID INSULATION 14" 6" RIGID INSULATION 18" 9" RIGID INSULATION 24" ALUMINUM BRACING TUBE FUSIBLE LINK RATED 360 DEGREES FAHRENHEIT MIN. 6" WIDE SINGLE PLY MEMBRANE FLASHING APPROVED LAP SEALANT LATION, SEE SPECS TPO - VENT PIPE PENETRATION SCALE: 1 1/2" = 1'-0" THERMALIZED LID FRAME EXTRUDED ALUMINUM CAP FLASHING EXTRUDED ALUMINUM METAL CURB MIN. 2" TAPERED RISE AT CURB ON HIGH SIDE EXISTING ROOF FRAMING REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1620i6 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 042013 PERMIT CENTER