HomeMy WebLinkAboutPermit PG18-0071 - 85C BAKERY - UPGRADE GAS LINE AND ADD 64,000 BTU TO NEW UNIT85C BAKERY
1341 SOUTHCENTER MALL
PGI 8-0071
Parcel No:
Address:
r'
LJ
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.Rov
PLUMBING/GAS PIPING PERMIT
9202470090 Permit Number:
1341 SOUTHCENTER MALL
Project Name: 85C BAKERY
Issue Date:
Permit Expires On:
PG 18-0071
5/18/2018
11/14/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
WESTFIELD PROPERTY TAX DEPT
PO BOX 130940 , CARLSBAD, WA,
92013
WILLIAM BRANCH
12119 274 AVE E , BUCKLEY, WA,
98321
PLUMBING PROS LLC
Address: 12119 274TH AVE E , BUCKLEY, WA,
98321
License No: PLUMBPL947PL
Lender:
Name:
Address:
/1/
Phone: (253) 732-8863
Phone: (360) 829-6539
Expiration Date: 10/13/2018
DESCRIPTION OF WORK:
UPGRADE GAS LINE AND ADD 64,000 BTU TO NEW UNIT
Valuation of Work: $3,500,00
Water District: TUKWILA
Sewer District: TUKWILA
Fees Collected: $129.28
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Signature:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
\
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date: S" v a
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 gauge.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
9002 ROUGH -IN GAS PIPING
9001 UNDERGROUND
CITY OF TUKWIII-
Community Development -Impartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
littp://www.TukwilaWA.gov
Plumbing/Gas Fermit No. p6/27- 067/
Project No.
Date Application Accepted: 5?—t
Date Application Expires: 1 t
(For office use only)
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: / 3 // Slu174 c ilk / L4- Suite Number:
Tenant Name:
PROPERTY OWNER
p
Name: �/L.L_/,t� WI 4 42 ��/rJGu
Address:/2/ /
ddress:/211 '( -2.7'11)44 A V
Name:
Phone:
1-3 - 7 - F'SeF3 .
Email: /J 1u.._ t� PLLJ /vlE/106ns
r— Pie
Address:
City:
State:
Zip:
CONTACT PERSON — person receiving all project
communication
p
Name: �/L.L_/,t� WI 4 42 ��/rJGu
Address:/2/ /
ddress:/211 '( -2.7'11)44 A V
City: (V C./LK—State:C' JA Zip:nj ? 72
Phone:
1-3 - 7 - F'SeF3 .
Email: /J 1u.._ t� PLLJ /vlE/106ns
r— Pie
Floor:
New Tenant: fl Yes p". No
PLUMBING CONTRACTOR INFORMATION
Company Name: eL U,vi slotf peri
Address: f / 11i q _, 7 511'14 AME 7M,
City: d ��j/� ' State Zip:
Phone: i 5-3 731 (3 Fax:
Cof'� U NNS 'P ?' / 11pL_ Exp Date: /0//.34
Tukwila Business License No.: jos, 09,97 2445
D
Valuation of Project (contractor's bid price): $ 3j "� D
Scope of Work (please provide detailed information): up A'ADt q4,5. c..1 /u P
A'JD 4 D I) Ddb 7J /u A=) U,v rt
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Sewer:
Page 1 of 2
Indicate type of plumbing fixtures and/or ,,,s piping outlets being installed and the quantity-
Fixture
uantity
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Shower, single head trap
Sinks
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
1
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
1
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Gas piping outlets
1
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gas
Each lawn sprinkler
system on any one meter
including backflow
protection devices
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY TJ LAWS OF THE STATE OF W, HINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER
Signature: t '
Print Name: uJ /LL_ 14 Ai ,Q ,if J /U c -fl
Mailing Address: P, t�%, 65)( l �b
Date: 5Jq I "
Day Telephone: 2, 53 7,. t g'e6
I/04 9,F.1/I
State
City
H: \Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-I I.docx
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
Receipt Number
R14456
DESCRIPTIONS ACCOUNT QUANTITY , PAID
PermitTRAK $129.28
PG18-0071 Address: 1341 SOUTHCENTER MALL Apn: 9202470090 $129.28
GAS $124.31
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
R000.322.100.00.00
0,00
$66.30
PLAN CHECK FEE
R000.322.103.00.00
0.00
$24.86
TECHNOLOGY FEE $4.97
TECHNOLOGY FEE R000.322.900.04.00 0.00 MIMI
TOTAL FEES PAID BY RECEIPT: R14456 $129.28
Date Paid: Wednesday, May 09, 2018
Paid By: PLUMBING PRO'S LLC
Pay Method: CHECK 53850
Printed: Wednesday, May 09, 2018 2:39 PM
1 of 1
trs
YSTEMS
&I.\
CITY OF TUKWILA BUILDING DIVISION •
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
R2 007)
PERMIT NO.
Projgt:‘r,f2e.
5 c a
Type of Inspection:
645 Red /1101.—
Address:
(JcoiineeWriX)
$//
Date Called:
Special n uctions:
..St",6-
-1-1 tzn e__, qfrIn
Date Wanted:
p.m.1
Z2
Requester S_
T7qVL
Phone No:
360 - 932_- 4/9oz_
igApproved per applicable codes. Corrections required prior to approval.
COMMENTS: A6
/IPPietees 57)9 Teit PA/94/5
Inspector:
Date: 6_23...m
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Plumbing Pros LLC
WiUiam A. Branch
PO Box 188
Buckley, WA 98321
360-829'533
City of Tukwila Building Department
Re: 85* Bakery @ Weisfield Mall
The gas line meter is on the maO roof, this line runs 3OO'and is11/4"|nsize. This gas line is a 2# gas
system. In order to access this gas line you need to go through three different roof hatches. Each roof
hatch put you on three different roofs. One hatch is on the malis main roof, the second hatch 15 above
the bowling aUey roof and the third hatch is on the 85* bakery roof. All three roofs can ony be accessed
from each roof hatch. There isa2#to7°regulator onthe roof tothe 85*Bakery. Off of this regulator is
a 1 1/4"X1"X1" tee. One 1" pipe goes to two HVAC units on the roof, the other line drops down through
the roof to 2 — Navien inline water heaters at 199,000 BTU each. 4 — Ovens at 34,500 BTU each. We are
adding 1—Gas range at64,OOOBTU which will bring the BTU onthis 1"line toS9@,OOO,with alineal feet
of 60' from regulator. There is an electric range existing that will be replaced with the new gas range,
this new range will fit under the existing hood.
Sincerely,
William A. Branch
Plumbing Pros
360-829-5334
REVIEVYCDFOR
CODE CON'FIIANCE
APPROVED
MAY � 1 �M��
�� ��^q
City of TukwilaBUILDING DIVISION
?GIB
'71
�����U����
""�~~�,°==
CITY OF TGKWUA
MAY G 9 2018
PERMIT CENTER
J,,NEAL, Ft 90
00 e L65L2 615', o o
GAS PIPING INSTALLATIONS
For Sl: 1 inch = 25,4 min, 1 foot = 304.8 mm, 1 pound per square inch = b 895 kPa, 1 -inch water column = 0.2488 kPa,
1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad.
Notes: t
1. NA means a flow of less thrill 10 eth.
+ 2. All table entries have been rounded to three significant digits.
- 32
MAY "092018
eERM1T CENTER
2009 INTERNATIONAL FUEL GAS CODE®
Copyrighted material licensed to Virginia Branch an 26-Oct-2010. Single user license only. Copying and Networking prohibited. Distributed by Thomson Scientific, Inc., www.techstreet.com.
Gas
Natural
TABLE 402,4(2)
Inlet Pressure
Less than 2 psi
SCHEDULE 40 METALLIC PIPE
Pressure Drop
0.5 in. w.c.
Specific Gravity
0.60
PIPE SIZE (Inch)
Nominal
1/,
3/4
1
11/4
11/2
2
21/,
3
4
5
6
8
10
12
Actual ID
0.622
0.824
1.049
1.380
1.610
2.067
1469
3,068
4.026
5.047
6.065
7.981
10.020
11.938
Length (ft)
Capacity In Cubic Feet of Gas Per Hour
10
172
360
678
1,390
2,090
4,020
6,400
11,300
23,100
41,800
67,600
139,000
252,000
399,000
20
118
247
466
957
1,430
2,760
4,400
7,780
15,900
28,700
46,500
95,500
173,000
275,000
30
95
199
374
7 8
1,150
2,220
3,530
6,250
12,700
23,000
37,300
76,700
139,000
220,000
o
81
170
320
657
985
1,900
3,020
5,350
10,900
19,700
31,900
65,600
119,000
189,000
50
72
151
284
583
873
1,680
2,680
4,740
9,660
17,500
28,300
58,200
106,000
167,000
60
65
137
257
528
791
1,520
2,430
4,290
.8,760
15 800
25,600
52,700
95,700
152,000
70
60
126
237
486
728
1,400
2,230
3,950
8,050
14,600
23,600
48,500
88,100
139,000
80
56
117
220
452
677
1,300
2,080
3,670
7,490
13,600
22,000
45,100
81,900
130,000
90
52
110
207
424
635
1,220
1,950
3,450
7,030
12,700
20,600
42,300
76,900
122,000
100
50
104
195
400
600
1,160
1,840
3,260
6,640
12,000
19,500
40,000
72,600
115,000
125
44
92
173
355
532
1,020
1,630
2,890
5,890
10,600
17,200
35,400
64,300
102,000
150
40
83
157
322
482
928
1,480
2.610
5,330
9,650
15,600
32.100
58,300
92,300
175
37
77
144
296 •
443
854
1,360
2,410
4,910
8,880
14,400
29,500
53,600
84,900
200
34
71
134
275
412
794
1,270
2,240
4,560
8,260
13400
27,500
49,900
79,000
250
30
63
119
244
366
704
1,120
1,980
4,050
7,320
11,900
24,300
44,200
70,000
300
27
57
108
221
331
638
1,020
1,800
3,670
6,630
10,700
22,100
40,100
63,400
350
25
53
99
203
305
587
935
1,650
3,370
6,100
9,880
20,300
36,900
58,400
400
23
49
92
189
283
546
870
1,540
3,140
5,680
9,190
18,900
34,300
54,300
450
22
46
86
177
266
5! 2
816
1,440
2,940
5.330
8,620
17 700
32 200
50,900
771
1,360
2,780
5,030
8.150
16,700
30,400
48,100
500
21
43
82
168
251
484
550
20
41
78
159
239
459
732
1,290
2,640
4,780
7.740
15,900
28.900
45,700
600
19
39
74
152
228
438
699
1,240
2,520
4,560
7,380
15,200
27,500
43,600
650
18
38
71
145
218
420
669
1,180
2,410
4,360
7,070
14,500
26,400
41,800
700
17
36
68
140
209
403
643
1,140
2,320
4,190
6,790
14,000
25,300
40,100
750
17
35
66
135
202
389
619
1,090
2,230
4,040
• , 1_
13,400
24,400
38,600
800
16
34
63
130
195
375
598
1,060
2,160
3,900
6,32(8
_.},13801
t,43 6
OW
850
16
33
61
126
189
363
579
1,020
2,090
3,780
;e U IIIz2,
11f
12I2,811 1 ,
900
15
32
59
122
183
352
561
992
2,020
3,660
5,930
*
U 1 + 1
5,IC
950
15
31
58
118
178
342
545
963
1,960
3,550 1
5,760
���17pl�
11,880
i , +�
34,000
1,000
14
30
56
115
173
333
530
937
1,910
3,460 f
5,600
11,500
20,900
33,100
1,100
14
28
53
109
164
316
503
890
1,810
3,280
5,320
MOO i
1940
831,400
1,200
13
27
51
104
156
301
480
849
1,730
3,130
•5,070
10,400
18,900
30,000
1,300
12
26
49
100
150
289
460
813
1,660
3,000
4,860
9,980
18,100
28,700
1,400
12
25
47
96
144
277
442
781
1,590
2,880
(�/,5Of
U�/
x7,600
1,500
11
24
45
93
139
267
426
752
1,530
2,780
pp4,670
®
•', '.'e
Vrvl
.
1,600
11
23
44
89 •
134
258
411
727
1,480
•2,680 �cfS4,�tniem��y.�
> � �+��
1,700
11
22
42
86
130
250
398
703
1,430
2,590
4,200
8,630
15,700
24,800
1,800
10
22
41
84
126
242
386
682
1,390
2,520
4,070
8,370
15,200
24,100
1,900
10
21
40
81
122
235
375
662
1,350
2,440
3,960
8,130
14 800
23400
2,000
NA
20
39
79
119
229
364
644
1,310
2,380
3,850
es
7,91IIt3ps
t,r ,5
14
0.. -ea
y2 0
st'Ali
For Sl: 1 inch = 25,4 min, 1 foot = 304.8 mm, 1 pound per square inch = b 895 kPa, 1 -inch water column = 0.2488 kPa,
1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad.
Notes: t
1. NA means a flow of less thrill 10 eth.
+ 2. All table entries have been rounded to three significant digits.
- 32
MAY "092018
eERM1T CENTER
2009 INTERNATIONAL FUEL GAS CODE®
Copyrighted material licensed to Virginia Branch an 26-Oct-2010. Single user license only. Copying and Networking prohibited. Distributed by Thomson Scientific, Inc., www.techstreet.com.
Table 12-9
LAL.. FT 300
✓h4 t1 -u 0009.00,
Table 12-9
Schedule 40 Metallic Pipe (NFPA 54: Table 6.2(c)1
UNIFORM PLUMBING CODE
Note: All table entries are rounded to 3 significant digits.
MAY 0 y 2Cid
; ERMIT CENTER
Gae:
Natural
Inlet Pressure:
2.0 psi
Pressure Drop:
1.0 psi
Specific Gravity:
0.60
Pipe Size (In.)
Nominal:
112
314
1
1-114
1-112
2
2-112
3
4
AcittallD:
0.622
0.824
1.049
1.380
1.610
2.067
2.469
3.068
4.026
Length (ft.)
Capacity in Cubic Fest of Gas par Hour
10
20
30
40
50
1,510
1,070
869
753
673
3,040
2,150
1,760
1,520
1,360
5,560
3,930
3,210
2,780
2,490
11,400
8,070
6,590
5,710
5,110
17,100
12,100
9,880
8,550
7,650
32,900
23,300
19,000
16,500
14,700
52,500
37,100
30,300
26,300
23,500
92,800
65,600
53,600
46,400
41,500
189,000
134,000
109,000
94,700
84,700
60
70
80
90
100
615
569
532
502
462
1,240
1,150
1,080
1,010
934
2,270
2,100
1,970
1,850
1,710
4,660
4,320
4,040
3,810
3,510
6,980
6,470
6,050
5,700
5,260
13,500
12,500
11,700
11,000
10,100
21,400
19,900
18,600
17,500
16,100
37,900
35,100
32,800
30,900
28,500
77,300
71,600
67,000
63,100
58,200
125
150
175
200
250
414
372
344
318
279
836
751
695
642
583
1,530
1,370
1,270
1,170
1,040
3,140
2,820
2,601
2,410
2,140
4,700
4,220
3,910
3,610
3,210
9,060
8,130
7,530
6,960
6,180
14,400
13,000
12,000
11,100
9,850
25,500
22,900
21,200
19,600
17,400
52,100
46,700
43,300
40,000
35,500
300
t s
400
450
500
253
232
216
203
192
528
486
452
424
401
945
869
809
759
717
1,790
1,660
1,560
1,470
2,910
2,670
2,490
2,330
2,210
5,600
5,150
4,790
4,500
4,250
8,920
8,210
7,640
7,170
6,770
15,800
14,500
13,500
12,700
12,000
32,200
29,600
27,500
25,800
24,400
550
600
650
700
750
182
174
166
160
154
381
363
348
334
322
681
650
622
598
576
1,400
1,330
1,280
1,230
1,180
2,090
2,000 •
1,910
1,840
1,770
4,030
3,850dA
3,680
3,540
3,410
6, ftE\
E
5,640 f)Ptl
5,440
1 E 4 oa u
C 4ppe=LIA6
`'
r C 2 oo
tD2Q300
19,600
800
850
900
950
1,000
149
144
139
135
132
311
301
292
283
275
556
538
522
507
493
1,140
1,100
1,070
1,040
1,010
1,710
1,650
1,600
1,560
1,520
3,290
3,190
3,090
3,000
2,920
5,080 5,250MAY
-4,930
4,780
`' 4'650CI}��t�,
2J
8,710
8,460
2iukwiI�I,8800°
`t.%II
18,300
17,800
17,200
1,100
1,200
1,300
1,400
1,500
125
119
114
110
106
262
250
239
230
221
468
446
427
411
396
960
917
878
843
812
1,440
1,370
1,320
1,260
1,220
2,770
2,640
2,530
2,430
2,340
1 L
!!l-4,1.1.
1 tl p910� i
Vl ab;997 a
4,040
3,880
3,740
7,*uu
7,140
6,860
6,600
i;i,[uu
14,600
14,000
13,500
1,600
1,700
1,800
2,000
102
99
96
93
91
214
207
200
195
189
382
370
358
3481,900
784
759
736
715
695
1,180
1,140
1,100
1,070
1,040
2,260
2,190
2,120
2,060
2,010
3,610
3,490
3,39
90�0
3,208'1
6,380
�,fy'���00
�"�j ,
3,6501'y
13,000
! K 00
11f f
Note: All table entries are rounded to 3 significant digits.
MAY 0 y 2Cid
; ERMIT CENTER
►i
if
30o L /NEgL. F -r Fitowa wic-rER re > u. A$ R
exisr, NGAVAc
-
FELE COPY
Plan review approval is s114o 67= and ornisticaa.
Approval of construction dominant does not authorize
the violation of any adopted code a7 orinance. Reesip3
of approved Feld Copy and conditions is admol dCs:
Date: a / / /
1-1Cf'S T i N6-
14 VAC^z
Cri of TukdIE
BUILDING DIVISION
REVISIONS
changes shalt he rn ,de to the scope
r f work prior approval of
T'- ' ;ta Bui'ding Division.
will require a new plan submittal
and may inc:ude additional plan review fees.
3I ex os'r,s&.
NAME Al
8 -Ti)
a5„srboc..
oVEN
13a. ao�ru
-C R
CODE CG;,,lrL1ANCE
APPROVED
MAY 11 2019
`
City of Tukwila
BUILDING DIVISION
G1B'OO71
ISE' ^.TE. PERMIT
i :',_SQUIRED FOR
C'Mechan:7
Drilect cal
G-rtumbtt
❑ Gas Pim
C;Zy of Tukvillc
BLok PING DIVISION
RECEIVED
CITY OF TUKWILA
►4AY 0 9 2018
PERMIT CENTER
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: PG18-0071 DATE: 05/09/18
PROJECT NAME: 85C BAKERY
SITE ADDRESS: 1341 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
r
Fire Prevention
Structural
L
Planning Division
LIPermit Coordinator fil
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 05/10/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews)
(ie: Zoning Issues)
DUE DATE: 06/07/18
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping PW D Staff Initials:
12/18/2013
PLUMBING PRO'S LLC
ik Washington State Department of
AP Labor & Industries
Hume ll'xnal)(>1 (2ontrict.
Safety & Health Claims & Insurance
Search L&I
Page 1 of 2
A -Z Index IIIp My !XI
Workplace Rights Trades & Licensing
PLUMBING PRO'S LLC
Owner or tradesperson
Principals
BRANCH, VIRGINIA
LEE, PARTNER/MEMBER
BRANCH, WILLIAM A, PARTNER/MEMBER
BRANCH, WILLIAM, AGENT
Doing business as
PLUMBING PRO'S LLC
WA UB I No,
602 659 236
12119 274TH AVE E
BUCKLEY, WA 98321
360-829-6539
PIERCE County
Business type
Limited Liability Company
Governing persons
VIRGINIA
LEE
BRANCH
WILLIAM A BRANCH;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
PLUMBING
License no,
PLUMBPL947PL
Effective — expiration
10/13/2006— 10/13/2018
Bond
CBIC
Bond accooit 00
SG9807
$6,000.00
Received by L&I Effective date
10/13/2006 10/12/2006
Expiration date
Until Canceled
Insurance
Liberty Northwest Ins Corp $1,000,000.00
Po icy no
BKA55236274
Received by L&I Effective date
11/20/2017 11/02/2012
Expration date
12/02/2018
Insurance history Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60265923684LIC=PLUMBPL947PL&SAW= 5/18/2018
PLUMBING PRO'S LLC
Savings rtml
No savings accounts during the previous 6 ytimeperiod.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
Infraction no.
PDOVE00379
Issue date
03/16/2017
Violation city
BUCKLEY
Type of violation y
PLUMBER INFRACTION
Description
Contractor failed to provide proper
supervision as required.
Satisfied
RCW/WAC
18.106.020
Violation amount
$250.00
Workers' comp
Do you know if the'business has employees? If so, verify the business is up-to-date on workerscomp premiums.
L&I Account ID Call L&I account representative for
125,688-00 account status.
Doing business as
PLUMBING PROS
Estimated workers reported
Incomplete premium report received.
L&I account contac,
T3 / DAVID PRYOR (360)902-4804 - Email: PRYD2350Inima.gov
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
No inspections durOg the previous 6 year period.
Page 2 of 2
VVashingion State Depl_ of Labor & Industries. Use of this Siteis subjeol to the laws of the slate of Washington.
Help us improve
https://securedni. wa.gov/verify/Detail.aspx?UBI=602659236&LIC=PLUMBPL947PL&SAW= 5/18/2018