HomeMy WebLinkAboutPermit PG18-0071 - 85C BAKERY - UPGRADE GAS LINE AND ADD 64,000 BTU TO NEW UNIT85C BAKERY 1341 SOUTHCENTER MALL PGI 8-0071 Parcel No: Address: r' LJ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT 9202470090 Permit Number: 1341 SOUTHCENTER MALL Project Name: 85C BAKERY Issue Date: Permit Expires On: PG 18-0071 5/18/2018 11/14/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 WILLIAM BRANCH 12119 274 AVE E , BUCKLEY, WA, 98321 PLUMBING PROS LLC Address: 12119 274TH AVE E , BUCKLEY, WA, 98321 License No: PLUMBPL947PL Lender: Name: Address: /1/ Phone: (253) 732-8863 Phone: (360) 829-6539 Expiration Date: 10/13/2018 DESCRIPTION OF WORK: UPGRADE GAS LINE AND ADD 64,000 BTU TO NEW UNIT Valuation of Work: $3,500,00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $129.28 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 \ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: S" v a This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING 9001 UNDERGROUND CITY OF TUKWIII- Community Development -Impartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Plumbing/Gas Fermit No. p6/27- 067/ Project No. Date Application Accepted: 5?—t Date Application Expires: 1 t (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: / 3 // Slu174 c ilk / L4- Suite Number: Tenant Name: PROPERTY OWNER p Name: �/L.L_/,t� WI 4 42 ��/rJGu Address:/2/ / ddress:/211 '( -2.7'11)44 A V Name: Phone: 1-3 - 7 - F'SeF3 . Email: /J 1u.._ t� PLLJ /vlE/106ns r— Pie Address: City: State: Zip: CONTACT PERSON — person receiving all project communication p Name: �/L.L_/,t� WI 4 42 ��/rJGu Address:/2/ / ddress:/211 '( -2.7'11)44 A V City: (V C./LK—State:C' JA Zip:nj ? 72 Phone: 1-3 - 7 - F'SeF3 . Email: /J 1u.._ t� PLLJ /vlE/106ns r— Pie Floor: New Tenant: fl Yes p". No PLUMBING CONTRACTOR INFORMATION Company Name: eL U,vi slotf peri Address: f / 11i q _, 7 511'14 AME 7M, City: d ��j/� ' State Zip: Phone: i 5-3 731 (3 Fax: Cof'� U NNS 'P ?' / 11pL_ Exp Date: /0//.34 Tukwila Business License No.: jos, 09,97 2445 D Valuation of Project (contractor's bid price): $ 3j "� D Scope of Work (please provide detailed information): up A'ADt q4,5. c..1 /u P A'JD 4 D I) Ddb 7J /u A=) U,v rt Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Sewer: Page 1 of 2 Indicate type of plumbing fixtures and/or ,,,s piping outlets being installed and the quantity- Fixture uantity Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) 1 Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 1 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 1 Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TJ LAWS OF THE STATE OF W, HINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Signature: t ' Print Name: uJ /LL_ 14 Ai ,Q ,if J /U c -fl Mailing Address: P, t�%, 65)( l �b Date: 5Jq I " Day Telephone: 2, 53 7,. t g'e6 I/04 9,F.1/I State City H: \Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R14456 DESCRIPTIONS ACCOUNT QUANTITY , PAID PermitTRAK $129.28 PG18-0071 Address: 1341 SOUTHCENTER MALL Apn: 9202470090 $129.28 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 R000.322.100.00.00 0,00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 MIMI TOTAL FEES PAID BY RECEIPT: R14456 $129.28 Date Paid: Wednesday, May 09, 2018 Paid By: PLUMBING PRO'S LLC Pay Method: CHECK 53850 Printed: Wednesday, May 09, 2018 2:39 PM 1 of 1 trs YSTEMS &I.\ CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 INSPECTION NO. INSPECTION RECORD Retain a copy with permit R2 007) PERMIT NO. Projgt:‘r,f2e. 5 c a Type of Inspection: 645 Red /1101.— Address: (JcoiineeWriX) $// Date Called: Special n uctions: ..St",6- -1-1 tzn e__, qfrIn Date Wanted: p.m.1 Z2 Requester S_ T7qVL Phone No: 360 - 932_- 4/9oz_ igApproved per applicable codes. Corrections required prior to approval. COMMENTS: A6 /IPPietees 57)9 Teit PA/94/5 Inspector: Date: 6_23...m REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Plumbing Pros LLC WiUiam A. Branch PO Box 188 Buckley, WA 98321 360-829'533 City of Tukwila Building Department Re: 85* Bakery @ Weisfield Mall The gas line meter is on the maO roof, this line runs 3OO'and is11/4"|nsize. This gas line is a 2# gas system. In order to access this gas line you need to go through three different roof hatches. Each roof hatch put you on three different roofs. One hatch is on the malis main roof, the second hatch 15 above the bowling aUey roof and the third hatch is on the 85* bakery roof. All three roofs can ony be accessed from each roof hatch. There isa2#to7°regulator onthe roof tothe 85*Bakery. Off of this regulator is a 1 1/4"X1"X1" tee. One 1" pipe goes to two HVAC units on the roof, the other line drops down through the roof to 2 — Navien inline water heaters at 199,000 BTU each. 4 — Ovens at 34,500 BTU each. We are adding 1—Gas range at64,OOOBTU which will bring the BTU onthis 1"line toS9@,OOO,with alineal feet of 60' from regulator. There is an electric range existing that will be replaced with the new gas range, this new range will fit under the existing hood. Sincerely, William A. Branch Plumbing Pros 360-829-5334 REVIEVYCDFOR CODE CON'FIIANCE APPROVED MAY � 1 �M�� �� ��^q City of TukwilaBUILDING DIVISION ?GIB '71 �����U���� ""�~~�,°== CITY OF TGKWUA MAY G 9 2018 PERMIT CENTER J,,NEAL, Ft 90 00 e L65L2 615', o o GAS PIPING INSTALLATIONS For Sl: 1 inch = 25,4 min, 1 foot = 304.8 mm, 1 pound per square inch = b 895 kPa, 1 -inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad. Notes: t 1. NA means a flow of less thrill 10 eth. + 2. All table entries have been rounded to three significant digits. - 32 MAY "092018 eERM1T CENTER 2009 INTERNATIONAL FUEL GAS CODE® Copyrighted material licensed to Virginia Branch an 26-Oct-2010. Single user license only. Copying and Networking prohibited. Distributed by Thomson Scientific, Inc., www.techstreet.com. Gas Natural TABLE 402,4(2) Inlet Pressure Less than 2 psi SCHEDULE 40 METALLIC PIPE Pressure Drop 0.5 in. w.c. Specific Gravity 0.60 PIPE SIZE (Inch) Nominal 1/, 3/4 1 11/4 11/2 2 21/, 3 4 5 6 8 10 12 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 1469 3,068 4.026 5.047 6.065 7.981 10.020 11.938 Length (ft) Capacity In Cubic Feet of Gas Per Hour 10 172 360 678 1,390 2,090 4,020 6,400 11,300 23,100 41,800 67,600 139,000 252,000 399,000 20 118 247 466 957 1,430 2,760 4,400 7,780 15,900 28,700 46,500 95,500 173,000 275,000 30 95 199 374 7 8 1,150 2,220 3,530 6,250 12,700 23,000 37,300 76,700 139,000 220,000 o 81 170 320 657 985 1,900 3,020 5,350 10,900 19,700 31,900 65,600 119,000 189,000 50 72 151 284 583 873 1,680 2,680 4,740 9,660 17,500 28,300 58,200 106,000 167,000 60 65 137 257 528 791 1,520 2,430 4,290 .8,760 15 800 25,600 52,700 95,700 152,000 70 60 126 237 486 728 1,400 2,230 3,950 8,050 14,600 23,600 48,500 88,100 139,000 80 56 117 220 452 677 1,300 2,080 3,670 7,490 13,600 22,000 45,100 81,900 130,000 90 52 110 207 424 635 1,220 1,950 3,450 7,030 12,700 20,600 42,300 76,900 122,000 100 50 104 195 400 600 1,160 1,840 3,260 6,640 12,000 19,500 40,000 72,600 115,000 125 44 92 173 355 532 1,020 1,630 2,890 5,890 10,600 17,200 35,400 64,300 102,000 150 40 83 157 322 482 928 1,480 2.610 5,330 9,650 15,600 32.100 58,300 92,300 175 37 77 144 296 • 443 854 1,360 2,410 4,910 8,880 14,400 29,500 53,600 84,900 200 34 71 134 275 412 794 1,270 2,240 4,560 8,260 13400 27,500 49,900 79,000 250 30 63 119 244 366 704 1,120 1,980 4,050 7,320 11,900 24,300 44,200 70,000 300 27 57 108 221 331 638 1,020 1,800 3,670 6,630 10,700 22,100 40,100 63,400 350 25 53 99 203 305 587 935 1,650 3,370 6,100 9,880 20,300 36,900 58,400 400 23 49 92 189 283 546 870 1,540 3,140 5,680 9,190 18,900 34,300 54,300 450 22 46 86 177 266 5! 2 816 1,440 2,940 5.330 8,620 17 700 32 200 50,900 771 1,360 2,780 5,030 8.150 16,700 30,400 48,100 500 21 43 82 168 251 484 550 20 41 78 159 239 459 732 1,290 2,640 4,780 7.740 15,900 28.900 45,700 600 19 39 74 152 228 438 699 1,240 2,520 4,560 7,380 15,200 27,500 43,600 650 18 38 71 145 218 420 669 1,180 2,410 4,360 7,070 14,500 26,400 41,800 700 17 36 68 140 209 403 643 1,140 2,320 4,190 6,790 14,000 25,300 40,100 750 17 35 66 135 202 389 619 1,090 2,230 4,040 • , 1_ 13,400 24,400 38,600 800 16 34 63 130 195 375 598 1,060 2,160 3,900 6,32(8 _.},13801 t,43 6 OW 850 16 33 61 126 189 363 579 1,020 2,090 3,780 ;e U IIIz2, 11f 12I2,811 1 , 900 15 32 59 122 183 352 561 992 2,020 3,660 5,930 * U 1 + 1 5,IC 950 15 31 58 118 178 342 545 963 1,960 3,550 1 5,760 ���17pl� 11,880 i , +� 34,000 1,000 14 30 56 115 173 333 530 937 1,910 3,460 f 5,600 11,500 20,900 33,100 1,100 14 28 53 109 164 316 503 890 1,810 3,280 5,320 MOO i 1940 831,400 1,200 13 27 51 104 156 301 480 849 1,730 3,130 •5,070 10,400 18,900 30,000 1,300 12 26 49 100 150 289 460 813 1,660 3,000 4,860 9,980 18,100 28,700 1,400 12 25 47 96 144 277 442 781 1,590 2,880 (�/,5Of U�/ x7,600 1,500 11 24 45 93 139 267 426 752 1,530 2,780 pp4,670 ® •', '.'e Vrvl . 1,600 11 23 44 89 • 134 258 411 727 1,480 •2,680 �cfS4,�tniem��y.� > � �+�� 1,700 11 22 42 86 130 250 398 703 1,430 2,590 4,200 8,630 15,700 24,800 1,800 10 22 41 84 126 242 386 682 1,390 2,520 4,070 8,370 15,200 24,100 1,900 10 21 40 81 122 235 375 662 1,350 2,440 3,960 8,130 14 800 23400 2,000 NA 20 39 79 119 229 364 644 1,310 2,380 3,850 es 7,91IIt3ps t,r ,5 14 0.. -ea y2 0 st'Ali For Sl: 1 inch = 25,4 min, 1 foot = 304.8 mm, 1 pound per square inch = b 895 kPa, 1 -inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour = 0.0283 m3/h, 1 degree = 0.01745 rad. Notes: t 1. NA means a flow of less thrill 10 eth. + 2. All table entries have been rounded to three significant digits. - 32 MAY "092018 eERM1T CENTER 2009 INTERNATIONAL FUEL GAS CODE® Copyrighted material licensed to Virginia Branch an 26-Oct-2010. Single user license only. Copying and Networking prohibited. Distributed by Thomson Scientific, Inc., www.techstreet.com. Table 12-9 LAL.. FT 300 ✓h4 t1 -u 0009.00, Table 12-9 Schedule 40 Metallic Pipe (NFPA 54: Table 6.2(c)1 UNIFORM PLUMBING CODE Note: All table entries are rounded to 3 significant digits. MAY 0 y 2Cid ; ERMIT CENTER Gae: Natural Inlet Pressure: 2.0 psi Pressure Drop: 1.0 psi Specific Gravity: 0.60 Pipe Size (In.) Nominal: 112 314 1 1-114 1-112 2 2-112 3 4 AcittallD: 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft.) Capacity in Cubic Fest of Gas par Hour 10 20 30 40 50 1,510 1,070 869 753 673 3,040 2,150 1,760 1,520 1,360 5,560 3,930 3,210 2,780 2,490 11,400 8,070 6,590 5,710 5,110 17,100 12,100 9,880 8,550 7,650 32,900 23,300 19,000 16,500 14,700 52,500 37,100 30,300 26,300 23,500 92,800 65,600 53,600 46,400 41,500 189,000 134,000 109,000 94,700 84,700 60 70 80 90 100 615 569 532 502 462 1,240 1,150 1,080 1,010 934 2,270 2,100 1,970 1,850 1,710 4,660 4,320 4,040 3,810 3,510 6,980 6,470 6,050 5,700 5,260 13,500 12,500 11,700 11,000 10,100 21,400 19,900 18,600 17,500 16,100 37,900 35,100 32,800 30,900 28,500 77,300 71,600 67,000 63,100 58,200 125 150 175 200 250 414 372 344 318 279 836 751 695 642 583 1,530 1,370 1,270 1,170 1,040 3,140 2,820 2,601 2,410 2,140 4,700 4,220 3,910 3,610 3,210 9,060 8,130 7,530 6,960 6,180 14,400 13,000 12,000 11,100 9,850 25,500 22,900 21,200 19,600 17,400 52,100 46,700 43,300 40,000 35,500 300 t s 400 450 500 253 232 216 203 192 528 486 452 424 401 945 869 809 759 717 1,790 1,660 1,560 1,470 2,910 2,670 2,490 2,330 2,210 5,600 5,150 4,790 4,500 4,250 8,920 8,210 7,640 7,170 6,770 15,800 14,500 13,500 12,700 12,000 32,200 29,600 27,500 25,800 24,400 550 600 650 700 750 182 174 166 160 154 381 363 348 334 322 681 650 622 598 576 1,400 1,330 1,280 1,230 1,180 2,090 2,000 • 1,910 1,840 1,770 4,030 3,850dA 3,680 3,540 3,410 6, ftE\ E 5,640 f)Ptl 5,440 1 E 4 oa u C 4ppe=LIA6 `' r C 2 oo tD2Q300 19,600 800 850 900 950 1,000 149 144 139 135 132 311 301 292 283 275 556 538 522 507 493 1,140 1,100 1,070 1,040 1,010 1,710 1,650 1,600 1,560 1,520 3,290 3,190 3,090 3,000 2,920 5,080 5,250MAY -4,930 4,780 `' 4'650CI}��t�, 2J 8,710 8,460 2iukwiI�I,8800° `t.%II 18,300 17,800 17,200 1,100 1,200 1,300 1,400 1,500 125 119 114 110 106 262 250 239 230 221 468 446 427 411 396 960 917 878 843 812 1,440 1,370 1,320 1,260 1,220 2,770 2,640 2,530 2,430 2,340 1 L !!l-4,1.1. 1 tl p910� i Vl ab;997 a 4,040 3,880 3,740 7,*uu 7,140 6,860 6,600 i;i,[uu 14,600 14,000 13,500 1,600 1,700 1,800 2,000 102 99 96 93 91 214 207 200 195 189 382 370 358 3481,900 784 759 736 715 695 1,180 1,140 1,100 1,070 1,040 2,260 2,190 2,120 2,060 2,010 3,610 3,490 3,39 90�0 3,208'1 6,380 �,fy'���00 �"�j , 3,6501'y 13,000 ! K 00 11f f Note: All table entries are rounded to 3 significant digits. MAY 0 y 2Cid ; ERMIT CENTER ►i if 30o L /NEgL. F -r Fitowa wic-rER re > u. A$ R exisr, NGAVAc - FELE COPY Plan review approval is s114o 67= and ornisticaa. Approval of construction dominant does not authorize the violation of any adopted code a7 orinance. Reesip3 of approved Feld Copy and conditions is admol dCs: Date: a / / / 1-1Cf'S T i N6- 14 VAC^z Cri of TukdIE BUILDING DIVISION REVISIONS changes shalt he rn ,de to the scope r f work prior approval of T'- ' ;ta Bui'ding Division. will require a new plan submittal and may inc:ude additional plan review fees. 3I ex os'r,s&. NAME Al 8 -Ti) a5„srboc.. oVEN 13a. ao�ru -C R CODE CG;,,lrL1ANCE APPROVED MAY 11 2019 ` City of Tukwila BUILDING DIVISION G1B'OO71 ISE' ^.TE. PERMIT i :',_SQUIRED FOR C'Mechan:7 Drilect cal G-rtumbtt ❑ Gas Pim C;Zy of Tukvillc BLok PING DIVISION RECEIVED CITY OF TUKWILA ►4AY 0 9 2018 PERMIT CENTER PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0071 DATE: 05/09/18 PROJECT NAME: 85C BAKERY SITE ADDRESS: 1341 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works r Fire Prevention Structural L Planning Division LIPermit Coordinator fil PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 05/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 06/07/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping PW D Staff Initials: 12/18/2013 PLUMBING PRO'S LLC ik Washington State Department of AP Labor & Industries Hume ll'xnal)(>1 (2ontrict. Safety & Health Claims & Insurance Search L&I Page 1 of 2 A -Z Index IIIp My !XI Workplace Rights Trades & Licensing PLUMBING PRO'S LLC Owner or tradesperson Principals BRANCH, VIRGINIA LEE, PARTNER/MEMBER BRANCH, WILLIAM A, PARTNER/MEMBER BRANCH, WILLIAM, AGENT Doing business as PLUMBING PRO'S LLC WA UB I No, 602 659 236 12119 274TH AVE E BUCKLEY, WA 98321 360-829-6539 PIERCE County Business type Limited Liability Company Governing persons VIRGINIA LEE BRANCH WILLIAM A BRANCH; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no, PLUMBPL947PL Effective — expiration 10/13/2006— 10/13/2018 Bond CBIC Bond accooit 00 SG9807 $6,000.00 Received by L&I Effective date 10/13/2006 10/12/2006 Expiration date Until Canceled Insurance Liberty Northwest Ins Corp $1,000,000.00 Po icy no BKA55236274 Received by L&I Effective date 11/20/2017 11/02/2012 Expration date 12/02/2018 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=60265923684LIC=PLUMBPL947PL&SAW= 5/18/2018 PLUMBING PRO'S LLC Savings rtml No savings accounts during the previous 6 ytimeperiod. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. PDOVE00379 Issue date 03/16/2017 Violation city BUCKLEY Type of violation y PLUMBER INFRACTION Description Contractor failed to provide proper supervision as required. Satisfied RCW/WAC 18.106.020 Violation amount $250.00 Workers' comp Do you know if the'business has employees? If so, verify the business is up-to-date on workerscomp premiums. L&I Account ID Call L&I account representative for 125,688-00 account status. Doing business as PLUMBING PROS Estimated workers reported Incomplete premium report received. L&I account contac, T3 / DAVID PRYOR (360)902-4804 - Email: PRYD2350Inima.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections durOg the previous 6 year period. Page 2 of 2 VVashingion State Depl_ of Labor & Industries. Use of this Siteis subjeol to the laws of the slate of Washington. Help us improve https://securedni. wa.gov/verify/Detail.aspx?UBI=602659236&LIC=PLUMBPL947PL&SAW= 5/18/2018