HomeMy WebLinkAboutPermit PG18-0073 - BOEING #9-053 - CRAC UNITS FOR COLD WATERBOEING #9-053 9725 E MARGINAL WAY S PGI 8-0073 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT 5624200990 Permit Number: PG18-0073 9725 E MARGINAL WAY S BLDG 9-053 Issue Date: 5/30/2018 Permit Expires On: 11/26/2018 Project Name: BOEING #9-053 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: DESIMONE TRUST BOEING 1201 THIRD AVE STE #5010 C/O BNY MELLON NA, SEATTLE, WA, 98101 MARTIN PROBST PO BOX 3707; M/C: 46-208 , SEATTLE, WA, 98124 HOLADAY PARKS INC 4600 S 134 PL , SEATTLE, WA, 98168 HOLADP1379NO Phone: (206) 852-4985 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: THE (3) CRAC UNITS IN UT17 WILL USE BUILDING DOMESTIC COLD WATER FOR THEIR HUMIDIFICATION FUNCTION. NO BACKFLOW PREVENTER OR CHECK VALVE REQUIRED DUE TO THE UNIT HAVING AN INTEGRAL AIR GAP AT THE HUMIDIFIER CONNECTION. Valuation of Work: $52,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $172.13 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Da I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: j!�//Lz.;�:� Print Name: Date: "`/ /moi$ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall' be maintained at the job and available to the plumbing inspector. 4: AA plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 0 o 8005 ROUGH -IN PLUMBING 0 0 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:///www.TukwilaW A.gov Plumbing/Gas Permit Project No Date Application Accepted: Date Application Expires:: 1' (For office risean!y)' PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 5624200990 9725 E Marginal Way S, Tukwila, WA 98108 Tenant Name: The Boeing Company Suite Number: 9-53 Bldg Floor: PROPERTY OWNER Name: Martin Probst - The Boeing Company Name: The Boeing Company City: Seattle State: WA Zip: 98124 Address: p0 Box 3707; M/C 46-208 Email: martin.r.probst@boeing.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Martin Probst - The Boeing Company Address: PO Box 3707; M/C 46-208 City: Seattle State: WA Zip: 98124 Phone: (206) 852-4985 Fax: (253) 657-4659 Email: martin.r.probst@boeing.com 1&2 New Tenant: ❑ Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Holaday-Parks, Inc Address: 4600 134th Place City: Tukwila State: WA Zip: 98168 Phone: (206) 248-9700 Fax: Contr Reg No.: HOLADI*836K2 Exp Date: 05/22/2019 Tukwila Business License No.: Valuation of Project (contractor's bid price): $ 52,000 Scope of Work (please provide detailed information): The (3) CRAC units in UT17 will use building domestic cold water for their humidification function. No backflow preventer or check valve required due to the unit having an integral air gap at the humidifier connection. See plan set for details. Building Use (per Int'l Building Code). Group B Occupancy (per Int'l Building Code): Group B Utility Purveyor: Water- Tukwila Sewer: Tukwila H:\Applications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system – per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 I Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) outIe ttasl:a Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller I Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: /'t- `� QST — ,.7,4 (5 co Signature: Date: 512-.2-/ 20(g (g Print Name: Martin Probst - The Boeing Company Day Telephone: (206) 852-4985 Mailing Address: PO Box 3707; M/C 46-208 Seattle WA 98124 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS ermitTRA Cash Register Receipt City of Tukwila ACCOUNT 18-0159 Add ess 9725mE MARGINAL WAY S. BLDG 9-053 QUANTITY PAID 2, Credit Card Fee $266,65 Credit Card Fee R000.369.908.00.00 0.00 $266.65 DEVELOPMENT 8,627 - PERMIT FEE R000.322.100.00.00 0.00 $5,225.77 PLAN CHECK FEE R000.345.830.00.00 0.00 $3,396.75 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $261.29 TECHNOLOGY FEE R000.322.900.04.00 0.00 $261.29 EL18-0470 Address: 9725 E MARGINAL AY,S BL IG 9-0! :5624200 X99. Credit Card Fee $579.59 Credit Card Fee R000.369.908.00.00 0.00 $579.59 ELECTRICAL $18,576.44 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $14,861.15 PLAN CHECK FEE R000.345.832.00.00 0.00 $3,715.29 TECHNOLOGY FEE $743.06 TECHNOLOGY FEE R000.322.900.04.00 0.00 $743.06 18-006. Address. 9725 E MARGINAL WAY'S BLDG 9-05 6242009 Credit Card Fee $262.27 Credit Card Fee R000.369.908.00.00 0.00 $262.27 MECHANICAL 8.406.10 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $6,691.73 PLAN CHECK FEE R000.322.102.00.00 0.00 $1,681.22 TECHNOLOGY FEE $336.24 TECHNOLOGY FEE R000.322.900.04.00 0.00 $336.24 PG18-0073 Address: 9725 E MARGINAL WAY 5 BLDG 9-053 in: 5624200 7 t3' Credit Card Fee $5. Credit Card Fee R000.369.908.00.00 0.00 $5.01 PLUMBING $160.69 PERMIT FEE R000.322.100.00.00 0.00 $95.40 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $32.14 Date Paid: Tuesday, May 22, 2018 Paid By: MARTIN R PROBST Pay Method: CREDIT CARD 009566 Printed: Tuesday, May 22, 2018 11:50 AM 1 of 2 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID 4 TECHNOLOGY FEE $6.43' TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14545 R000.322.900.04.00 0.00 $6.43 $38,230.79 Date Paid: Tuesday, May 22, 2018 Paid By: MARTIN R PROBST Pay Method: CREDIT CARD 009566 Printed: Tuesday, May 22, 2018 11:50 AM 2 of 2 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit RA* 0:$73 INSPE ON NO. PERMIT N4. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Got 1, *9 -osTh, Type of Inspection: r.aAttousa. 4 le. =III 'I _ Ad ress: 1125 £ M44.4 wild..— 0441 S Date Called: Special Instructions: C, aft ?6,1., -,,Date Wanted: ^l1' t$ a.m. Requester /ri°4'(f�5 Phone No: 1 0.4(•-10 "t - b _ 1 N- 14 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: tayi ?L-ai Inspector: Ci if Date: C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director October 26, 2018 Martin Probst PO Box 3707: Mail Stop 46-208 Seattle, WA 98124 RE: Request for Extension #1 Permit Number PG18-0073 Dear Mr. Probst, This letter is in response to your written request for an extension to Permit PG18-0073. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through May 26, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rachelle Ripley Permit Technician File: Permit No. PGI8-0073 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov Friday, October 26, 2018 City of Tukwila Dept. of Community Development Attn: Jerry Hight 63008outhcenterB|vd., Suite 100 Tukwila, WA. 98188-2544 Subject: Dear Mr. Hight; Permit Extension Request Pn4ect#.PG18'UO73 Project Description: 9-53 UT17 & H3 Server Migration The Boeing Company Per our recrds we show that Ponnh#PG18-0O73 expires on 11/26/2018. This permit is for Boeing's 9-53 buUding server migration project. Work in that space is on-going and is expected to continue into the first quarter of 2019. Per Section 105 of the International Building Code "[A] 105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced, The building official is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated." The Boeing Company kindly requestsanextenoionm(18Odoyoforthiopnojec and appreciates your consideration of this matter. Best Regards, Martin R. Probst Code Compliance & Permitting The Boeing Company POBox 37O7:Mail Stop 4O'2O8 Seattle, VVA98124 206'852-4985 Author 'wxp, Request for Extension # Current Expiration Date: Extension Request: U Approved for days | DcoicJ provide explanation) Signature/Initials 10/1/2018 City of Tukwila Department of Community Development MARTIN PROBST PO BOX 3707; M/C: 46-208 SEATTLE, WA 98124 RE: Permit No. PG 18-0073 BOEING #9-053 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/26/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/26/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, cliel'le Rililey Permit Technician File No: PG18-0073 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COP? 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0073 DATE: 05/23/18 PROJECT NAME: THE BOEING COMPANY #9-053 SITE ADDRESS: 9725 E MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 6 s' -?-14— ( Building Division II blic Works /1/401- Fire Prevention Structural n Planning Division LIPermit Coordinator n PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 05/24/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 06/21/18 Approved with Conditions 71, Denied (corrections entered in Reviews) (ie: Zoning Issues) L Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 HOLADAY PARKS INC ilk Washington State Department of Labor & Industries Horn Espanol Contact Safety & Health Claims & Insurance rl-earch L81 Page 1 of 3 A -Z Index Hdp My 11X1 Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) Doing business as HOLADAY PARKS INC 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County WA UB I Business type 578 004 089 Corporation Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI3791\10&SAW= 5/30/2018 HOLADAY PARKS INC Governing persons DAVID BECK DAN CONNELL; JERRY FREEL; BIJIT GIRI; GRACE PIZZEY; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/21/1983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no 23000452 $12,000,00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTC01F465357C0F17 $1,000,000 00 Received by L&I Effective date 10/31/2017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LW Tax debts No UM tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 1 of Year 2018 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects, Contractor Strikes No strikes have been issued against this contractor. Page 2 of 3 Help us improve https://secureini.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 5/30/2018 HOLADAY PARKS INC Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspeulin.) 317940948 Location 1007 Stewart St Seattle, WA 98101 Inspe•-• 08/09/2016 Insp, 317940177 Loc 1011 Western Ave, Suite 1000 Seattle, WA 98104 Inspe • - 1, -..,sults date 05/0512f:16 Inspec:i-",n no 3179401`.6 Lo 4600 S 134th PI Tukwila, WA 98168 Insp 06/11,11 Insp' 3173127 -) Lc& 1011 Dexter Ave Seattle, WA 98102 lnsp suds date 05/08:2L t Insr, 317278427 2nd and 110th Ave Bellevue, WA 98004 Ins......dt 09/04 3162563 :1 t 3003 W Casino Rd Everett, ;VA 98204 No violations No violations No violations No violations No violations Violations Page 3 of 3 13 Washi;•„; , 2.:4A. a Labor & Industries. Use of this site is subject to the laws of the stale of Washington. Help us improve https://securc. I n i .wa.gov/verify/Detail.aspx?UBI=578004089&LIC—HOLADPI379NO&SAW= 5/30/2018 BO 9 /25 DORTIO\S OF W LLAV v C TY D LA\ ❑ n 99 14-01 7-127 KING COUNTY AIRPORT OFFICE .CENTER (FAA) AIR MUSEUM PROJECT SITE FROM DOWNTOWN SEATTLE BOEING FIELD EAST MARGINAL WAY 99 CORPORATE PARK FROM SEATTLE-TACOMA AIRPORT DEVELOPvE\TAL 900 EXIT 157 599 TUKWILA CE\TES EXIT 158 Q FROM KENT Sc AUBURN EXIT 157 900 NO SCALE D AS A, STCTO FTT U U VAR DARCFL D A A OP \G RG S TOW\S DA\ 9 V B N v 9 A ID 23 G CO ER 56220 A 5J A 0\ \ORT TV, WAS 0990 V 98 9 AREA VA ID 3UILD1\G ADDHSS: 9725 EAST vAKI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT SITE 3UILDI\G 9-53 LOCATIO\ NO SCALE RA\ \G SO� J L TON 08 FAST, FILE COPY Permit ry®. VGl8.0073 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: s--/�35/., i8 City of Tukwila BUILDING DIVISION COIF S v VARY 9-53 SUMMARY: LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: FIRST FLOOR SECOND FLOOR BUILDING GROSS BUILDING HEIGHT STORIES OCCUPANT LOAD: FIRE PROTECTION SEISMIC DESIGN CATEGORY TUKWILA MUNICIPAL . CODE CHAPTER 18, MIC/H ZONE MAXIMUM HEIGHT 125 FT. 2015 IEBC, R0151 FC, 2015 IBC AS AMENDED, 2015 WASHINGTON, STATE ENERGY CODE AND CITY OF TUKWILLA TITLE 16; WAC 51-11 BARRIER FREE CODE AS ADOPTED OR AMENDED, AND COMPLIANCE WITH THE CITY OF TUKWILLA ZONING CODES GROUP B TYPE II B. PRINKLERED 54,281 (EXISTING) 43,080 (EXISTING) 97,901 (EXISTING) 44ft ± TO. TOP OF WALL 2 (EXISTING) NO CHANGES FULLY SPRINKLERED D SCOPE OF WORK: REVISIONS No changes shall f?h made to the scope et amr % withrpft prior 2,,cproval of p izev gia B-t.IZtling l-iG�`DSftP>i_ VOTE: n,314scins rci4 require a new ran submittal cad may irlc,!utfe additional plan review fees. THE SCOPE OF WORK FOR THIS PROJECT INCLUDES RELOCATION OF EXISTING SERVER RACKS AND ASSOCIATED EQUIPMENT FROM THE 18-61 BUILDING IN KENT, WASHINGTON TO THE 9-53 BUILDING. ROOMS H3 AND UT17 SHALL CONTAIN THE LOCAL SERVERS, ROOM 12BB4 SHALL FUNCTION AS THE NETWORK ROOM, AND ROOM 22BB2 SHALL FUNCTION AS THE UPS ROOM. EQUIPMENT, SUCH AS MECHANICAL CONDENSER UNITS AND EMERGENCY GENERATORS, SHALL BE LOCATED OUTSIDE OF BUILDING 9-53 TO SUPPORT THE RECONFIGURED INTERIOR SPACES. WORK SHALL INCLUDE, BUT IS NOT LIMITED TO, INSTALLATION AND ANCHORAGE OF MECHANICAL AND ELECTRICAL EQUIPMENT, SUPPORT OF CABLE TRAYS, CONSTRUCTION OF FULL HEIGHT INTERIOR WALLS, INSTALLATION OF EXTERIOR CONCRETE PADS AND FOUNDATIONS, BOLLARDS AND FENCES, INCLUDING ALL RELOCATED ELECTRICAL AND MECHANICAL WORK. CURRENT OCCUPANT LOADS AND EGRESS PATHS WILL REMAIN UNCHANGED DUE TO RECONFIGURATIONS. OWNER CONTACT: THE BOEING COMPANY (BOEINC*294ML 01.18.2019) MARTIN R. PROBST martin.r.probst@boeing.com (206) 852-4985 ,.- ROOM ISSUED FOR PERMIT MAY 15, 2018 SEPARATE PERMIT REQUIRED FOR: 4chanical Electrical 0 Pl mbing LL,as Piping City of Tukwila CIPLIDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 5 2018 City of Tukwila BUILDING DIVISION E. CEI V/ED CITY OF TUKWILA MAY 222018 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET PHONE: (253) 474-9449 TACOMA, WA. 98409 I FAX: (253) 474-9449 http://www.sItts-hIll-engineers.com/ Project No.: 18033 Project Mgr.: BKL Proj. Engineer: DCB Proj. Drafter: LAM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE UT17 AND H3 SERVER MIGRATION W5723449 SITTS BKL 05.15.18 WA' ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. McVay CHECKED B. Leslie ENGINEER D. Boileau DATE 03.13.18 03.13.18 03.13.18 SUBTITLE TITLE COVER SHEET UT17 AND H3 SERVER MIGRATION CURRENT REVISION W5723449 SYMBOL DATE 05.15.18 SHEET AO CHECKED B. Leslie 03.13.18 APPROVED APPROVED ARCHITECTURAL BUILDING 09-53 DEV. CENTER, WA JOB NO. W5723449 COMP NO. DWG NO. 09-053—AO \DLX OP CRAW \GS INCLUDED IN SET SHEET NO. DRAWING TITLE REV DRAWING NO. VECHA\ICAL • 09-053-MOA MOA LEGEND, ABBRAVIATIONS AND NOTES A 05,15,18 • 09-053-MOB MOB MECHANICAL LEGEND A 05.15.18 • 09-053.1-IM113 IM113 FIRST FLOOR PLUMBING - NORTH G 05.15.18 • 09-053.1-M505 M505 DETAILS -MECHANICAL A 05.15.18 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 5 201s City of Tukwila BUILDING DIVISION ISSUED FOR PERMIT MAY 15, 2018 RECEIVED Ci-t Y OF TUKWILA PY4222018 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL ■ STRUCTURAL • SURVEYING 4815 CENTER STREET I PHONE: (253) 474-9449 I FAX: (253) 474-9449 http://www.sitts-hill-eng lneers.com/ TACOMA, WA. 98409 Project No.: 18033 Project Mgr.: BKL Proj. Engineer: DCB Proj. Drafter: LAM SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE UT17 AND H3 SERVER MIGRATION W5723449 SITTS BKL 05.15.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN L. McVay CHECKED B. Leslie ENGINEER D. Boileau CHECKED B. Leslie APPROVED DATE 03.13.18 03.13.18 03.13.18 03.13.18 SUBTITLE TITLE SHEET INDEX UT17 AND H3 SERVER MIGRATION BUILDING 09-53 CURRENT REVISION W5723449 SYMBOL DATE 05.15.18 SHEET Al JOB NO. W5723449 COMP NO. 10:59:12 PM SMCCARTHY: 8/16/2017 APPROVED ARCHITECTURAL DEV. CENTER, WA DWG NO. 09-053-Al MECHANICAL ABBREVIATIONS SYMBOL DESCRIPTION MECHANICALABBREVIATIONS SYMBOL DESCRIPTION GENERAL CONSTRUCTION NOTES 1. PLANS ARE DIAGRAMMATIC AND DO NOT SHOW ALL BRANCHES, VALVES, SPECIALTIES AND EQUIPMENT. A AAV AD ADD AF AFF AP AUD AVG BI BDD BFP BHD BHP BOD BOP BOS BTU BTU H BW C Cv `C CAP CC CCW CFM CI CONN CPLG CW DA DB DBD DIA, DN DS DWG dB EA EAT EFF ELL ELEV, EL ESP EVAP EWT EXH EXIST EXT `F FC FLR FOB FOE FOIC FOT FPM FS FT FV GAL GPM GALV GA HC HD HORIZ HP HPC HR HVAC ID IE IGV IN KW KVA LAT LBS, # LWT MA MAX MBH MCC MIN MOV MTD, MTG ANCHOR AUTOMATIC AIR VENT ACCESS DOOR ANGULAR DOWN DISCHARGE AIR FOIL WHEEL ABOVE FINISHED FLOOR ACCESS PANEL ANGULAR UP DISCHARGE AVERAGE BACKWARD INCLINED WHEEL BACK DRAFT DAMPER BACK FLOW PREVENTER BOTTOM HORIZONTAL DISCHARGE BRAKE HORSE POWER BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR BUTTWELD COMMON FLOW COEFFICIENT TEMPERATURE — DEGREES CELSIUS CAPACITY COOLING COIL COUNTER CLOCKWISE ROTATION CUBIC FEET PER MINUTE CAST IRON CENTER LINE CONNECTION COUPLING CLOCKWISE ROTATION DIRECT ACTING DRY BULB TEMPERATURE DOWN BLAST DISCHARGE DIAMETER DOWN DOWNSPOUT DRAWING DECIBELS EXHAUST AIR / EACH ENTER AIR TEMPERATURE (`F) EFFICIENCY ELBOW ELEVATION EXTERNAL STATIC PRESSURE EVAPORATOR ENTERING WATER TEMPERATURE EXHAUST EXISTING EXTERIOR / EXTERNAL TEMPERATURE — DEGREES FAHRENHEIT FORWARD CURVE WHEEL FLOOR FLAT ON BOTTOM FACE OF FLANGE FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FLAT ON TOP FEET PER MINUTE FLOW SWITCH FEET FACE VELOCITY FPM GALLONS GALLONS PER MINUTE GALVANIZED GAGE, GAUGE HEATING COIL HEAD — FEET OF WATER HORIZONTAL HORSEPOWER HIGH PRESSURE CONDENSATE HOUR HEATING, VENTILATING AND AIR CONDITIONING INSIDE DIAMETER INVERT ELEVATION INLET GUIDE VANE INCHES KILOWATT KILOVOLT —AMPERE LEAVING AIR TEMPERATURE (`F) POUNDS LEAVING WATER TEMPERATURE (`F) MIXED AIR MAXIMUM HEAT CAPACITY BTU PER HOUR X 1000 MOTOR CONTROL CENTER MINIMUM MOTOR OPERATED VALVE MOUNTED, MOUNTING NC NIC NO NTS NPSH OA OBD OF OS&Y OD PBD PD/o P POS PRESS PRV PS PSIG PSV RA RECT REF RH RM ROT RPM RQD RTN SA SCFM SHC SHF SO SOV SP SQ SS STL SW SUCT SV TDH TEMP TH THC THD THRD TOD TOS TOP TP TS TSP TV TYP NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN / NUMBER NOT TO SCALE NET POSITIVE SUCTION HEAD OUTSIDE AIR OPPOSED BLADE DAMPER OVERFLOW OUTSIDE SCREW AND YOKE OUTSIDE DIAMETER PARALLEL BLADE DAMPER PRESSURE DROP OR DIFFERENTIAL PRESSURE POSITION PRESSURE PRSSURE REGULATING VALVE PRESSURE SWITCH PRESSURE — POUNDS PER SQUARE INCH, GAUGE PRESSURE RELIEF (SAFETY) VALVE REVERSE ACTING (CONTROLLER) / RETURN AIR RECTANGULAR REFERENCE RELATIVE HUMIDITY ROOM ROTATION REVOLUTIONS PER MINUTE REQUIRED RETURN SUPPLY AIR CUBIC FEET OF AIR, AT STANDARD CONDITIONS SENSIBLE HEAT CAPACITY SENSIBLE HEAT FACTOR SCREENED OPENING SOLENOID OPERATED VALVE STATIC PRESSURE SQUARE STAINLESS STEEL STEEL SOCKET WELD SUCTION SAFETY RELIEF VALVE TOTAL DYNAMIC HEAD (FEET OF WATER) TEMPERATURE TOTAL HEAD (FEET OF WATER) TOTAL HEAT CAPICITY TOP HORIZONTAL DISCHARGE THREADED TOP OF DUCT TOP OF STEEL TOP OF PIPE TOTAL PRESSURE TEMPERATURE SWITCH TOTAL STATIC PRESSURE TURNING VANE TYPICAL UBD UP BLAST DISCHARGE VAV VD VP VERT VTA VTR WB WG W/ NOTES: VARIABLE AIR VOLUME VOLUME DAMPER VELOCITY PRESSURE VERTICAL VENT TO ATMOSPHERE VENT THROUGH ROOF WET BULB TEMPERATURE WATER GAUGE (INCHES OF WATER) WITH DESIGNATES EQUIPMENT APPEARING ON MECHANICAL EEQU PME FOSCHESDULES,R SEE DRAWINGS STARTING 2. SEE DRAWING M 1 B FOR ABBREVIATIONS OF PIPING, IDENTIFICATIONS AND SPECIALTIES. 3. SEE CONTROL SCHEMATIC(S) FOR ADDITIONAL ABBREVIATIONS AND SYMBOLS RELATING TO CONTROL SYSTEMS. 4. DIFFUSERS WITHOUT ARROWS TO INDICATE AIR FLOW DIRECTION ARE FOR FLOW IN ALL DIRECTIONS (TWO DIRECTIONS FOR LINEAR DIFFUSERS). ARROWS ARE USED TO INDICATE DESIRED AIR FLOW DIRECTIONS IN OTHER CASES. PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACAL/ASIC LAB RELOCATION 12787 SAZAN/SS 07.12.12 RECORD DRAWING 12787 SAZAN/SS 08.13.13 A UT17 AND H3 SERVER MIGRATION W5723449 FSi AWL 05.15.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED D Solutions & Service RAWN SUBTITLE DATE CHECKED 2. ALL PIPING, VALVES AND EQUIPMENT ARE TO BE REMOVED IN DEMOLITION AREAS. 3. VALVES INDICATED FOR SHUT—OFF ISOLATION ARE SHOWN IN APPROXIMATE LOCATIONS. REFER TO REFERENCED BLDG. DRAWINGS FOR DETAILED SYSTEMS. 4. FIELD VERIFY EXACT LOCATIONS VALVES, EQUIPMENT AND PIPING. 5. CONTRACTOR TO VERIFY SYSTEM SHUT DOWN PRIOR TO ANY REMOVAL WORK. 6. CONTRACTOR TO RE —OPEN VALVES AFTER COMPLETION OF REMOVAL, CAP, & CUT TO RESTORE SYSTEM OPERATION WHERE REQUIRED. 7. SYSTEM SHUT DOWN REMOVAL, CUT & CAP SHALL ONLY BEGIN AFTER NEW, RE—ROUTED SYSTEM IS IN PLACE FOR SERVICE CONTINUITY WHERE REQUIRED. 8. ALL SYSTEMS SHALL BE DRAINED AND DISPOSAL OF FLUIDS HANDLED AS REQUIRED PER BOEING STANDARDS. 9. MECHANICAL DRAWINGS SHOW DISCONNECT AND RECONNECT POINTS AT THE PROJECT'S BOUNDARIES. AN ATTEMPT WAS MADE TO SHOW MAJOR MECHANICAL UTILITY WORK WITHIN THE PROJECT'S BOUNDARIES. THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL/DISPOSAL OF ALL MECHANICAL WORK WITHIN THE PROJECT'S BOUNDARY. ENERGY CODE COMPLIANCE NOTES 1. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE 2015 EDITION, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 2. ALL MECHANICAL EQUIPMENT SHALL BE LISTED AND APPROVED BY A TESTING AGENCY. 3. ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER IMC, C402 LEAKAGE REQUIREMENTS AND IBC VAPOR RETARDER REQUIREMENTS. SEE SPECIFICATIONS FOR MORE INFORMATION. ISSUED FOR PERMIT MAY 15, 2018 LEGEND, ABBREVIATIONS, AND NOTES CURRENT REVISION W5723449 REVIEWED FOR CODE COMPLIANCE APPROVLD MAY 252M18 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKVVILA MAY 2 2 2018 PERMIT CENTER SYMBOL A DATE 05.15.18 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER UT17 AND H3 SERVER MIGRATION BUILDING 09-53 DEV. CENTER, WA SHEET MOA M1 JOB NO. 12787 COMP NO. DWG NO. 09-053—MOA 05.15.18 SIGNED MECHANICAL LEGE\D SYMBOL DESCRIPTION GENERAL NEW WORK EXISTING WORK »1////// EXISTING TO BE REMOVED - - HIDDEN OR BELOW GRADE CROSSING LINES, NO CONNECTION CONNECTING LINES C- rA-R/ EQUIPMENT MARK NUMBER PUMP 47 INSULATED PIPE -6 9- INSULATED PIPE WITH ELECTRIC HEAT TRACING --6.__-S-- i POINT OF CONNECTION PIPE IDE\TIFICATIO\ COMPRESSED AIR, PLANT Al ACID WASTE IAWI CONDENSATE RETURN (GRAVITY) --IC CHEMICAL FEED Cr1 CHILLED WATER RETURN -I CHWR I- CHILLED WATER SUPPLY -I CHWS I- CORROSION RESISTANT VENT -ICRVI- CORROSION RESISTANT WASTE -ICRWI- COOLING TOWER FILTER RETURN -I CTFR}- COOLING TOWER FILTER SUPPLY -ICTFSI- COOLING TOWER RETURN -ICTRI- COOLING TOWER SUPPLY -ICTSI- DOMESTIC COLD WATER ICW DEIONIZED WATER IDII DISTILLED WATER IDWI FIRE LINE, AHEAD OF ALARM VALVE Ti FUEL OIL RETURN FORI FUEL OIL, SUPPLY -I FOS I- FUEL OIL VENT -IFOVI- G NATURAL GAS REFRIGERANT HOT GAS DISCHARGE -1 HGD CONDENSATE RETURN (PRESSURE) ITEPTI STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) IIIPSI DOMESTIC HOT WATER SUPPLY IIIW DOMESTIC HOT WATER CIRCULATING -IHWCI- HEATING WATER RETURN IIIWR HEATING WATER SUPPLY -IHWSI- INSTRUMENT AIR IAI INDIRECT DRAIN -I ID INDUSTRIAL WASTE -IIW LIQUID PETROLEUM GAS -I LPG I STEAM SUPPLY (LOW PRESS, 0-15 PSIG) -ILPS STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) MPSI CONDENSATE RETURN (PUMPED) [TTh PROCESS WATER PWI IRD REFRIGERANT DISCHARGE REFRIGERANT LIQUID --IRL REFRIGERANT SUCTION (GAS) IRS1 MECHANICAL LEGEND SYMBOL DESCRIPTION RAIN WATER LEADER —I RWLI- SPRINKLER LINE --{ SI SANITARY WASTE BELOW GRADE OR FLOOR --ISANI-- SANITARY WASTE ABOVE GRADE OR FLOOR -I SANI- STEAM SUPPLY -I STMI- STORM DRAIN --I STS I-- VACUUM -H VAC I- ---H VI---- VENT PIPE FITTI\GS x Y PIPING MATERIAL CHANGE, X TO Y I SCREWED FITTING OR AS SPECIFIED FLANGED FITTING II a WELDED FITTING PIPE TEE, STRAIGHT I+I PIPE TEE, OUTLET UP OR TOWARD -1 O I PIPE TEE, OUTLET DOWN OR AWAY 18I PIPE UNION --'I PIPE CROSS I$I R PIPE ELBOW, 90' SHORT RADIUS I+ PIPE ELBOW, 90' LONG RADIUS I+ it PIPE ELBOW, REDUCING PIPE ELBOW, 45' X PIPE ELBOW, TURNED UP OR TOWARD —0 PIPE ELBOW, TURNED DOWN OR AWAY 10 PIPE CAP SCREWED OR SOLDER JOINT ] D PIPE CAP, WELDED OR GROOVED BLIND FLANGE II PIPE PLUG IQ REDUCING PIPE FLANGE ID PIPE REDUCER CONCENTRIC 0 PIPE REDUCER ECCENTRIC --J PIPE ANCHOR X / PIPE HANGER SPRING HANGER PIPE GUIDE Il FLEXIBLE PIPE CONNECTION IIIII;1 EXPANSION JOINT DIRECTION OF FLOW SLOPE DIRECTION OF SLOPE, DOWN HOSE BIBB HB NON FREEZE HOSE BIBB NFHB WASTE F TT \GS 0 FD FLOOR DRAIN 0 FS FLOOR SINK TRENCH DRAIN DMMUUDITD O WR WASTE RECEPTOR, ROOF 0 FFD FUNNEL FLOOR DRAIN °RD (OFD) ROOF DRAIN (OVERFLOW DRAIN - ROOF) S&01 SAND AND OIL INTERCEPTOR 0 o IWCO WALL CLEAN OUT MECHA\ICAL LEGEND SYMBOL DESCRIPTION FCO —0 FLOOR CLEAN OUT ICO CLEAN OUT, EXPOSED --4. WASTE PIPING BEND I LATERAL SANITARY WYE AND 1/8TH BEND PIPING SPECIALTIES -j-/ GATE VALVE, OPEN / CLOSED -) ANGLE GLOBE VALVE, ELEVATION / PLAN GATE VALVE OUTSIDE SCREW AND YOKE ii GATE VALVE WITH HOSE CONNECTION 0 O -f 1-/ 1 1 GLOBE VALVE, OPEN / CLOSED BALANCE ->r<1 VALVE PLUG PRESSURE REGULATING VALVE -414-- `V PRESSURE RELIEF VALVE / SAFETY VALVE PETCOCK - BALANCE VALVE WITH METERING PORTS SOLENOID OPERATED VALVE -494 � '4 MOTOR OPERATED VALVE -M SWING CHECK VALVE WITH FLOW LIFT CHECK VALVE -11-/ -C ]-/ [ ] BALL VALVE, OPEN / CLOSED BUTTERFLY K2 VALVE A 2 WAY CONTROL VALVE 3 WAY CONTROL VALVE ITI PLUG VALVE / STOP COCK ► Q FLOAT VALVE• *MR QUICK OPENING VALVE ----N7-- WYE STRAINER (WITH DRAIN VALVE) -jt\O- COOLING COIL CHILLED WATER HEATING COIL �AAV AUTOMATIC AIR VENT (WITH DRAIN) -MAV MANUAL AIR VENT (WITH DRAIN) I�I PRESSURE GAUGE WITH VALVE I_I THERMOMETER, LINE MOUNT THERMOMETER, SEPARABLE WELL MOUNT II TEST PLUG / A AIR DROP, SIMPLEX / DUPLEX o / 46 AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX $H I-C PETE'S PLUG, WITH BALL VALVE TRAP SEAL PRIMER VALVE -1BFP- BACKFLOW PREVENTER FLOW METER, VENTURI TYPE 1 ' I TRAP, FLOAT O VALVE BOX 400 AUTOMATIC FLOW CONTROL VALVE MR (NUMBER INDICATES GPM) TRAP T STEAM Q VACUUM DROP (LAB VAC) OV VACUUM OUTLET (LAB VAC) HARD PIPED I "1 VACUUM CLEANING OUTLET VALVE IN RISER SPECIFIED) I<Q I (TYPE IVECHA\ICAL LEGE\D SYMBOL DESCRIPTION FIRE PROTECTION o SPRINKLER HEAD, UPRIGHT, NEW SPRINKLER HEAD, PENDENT, IN LINE, NEW ICI SPRINKLER HEAD, PENDENT, OFFSET, NEW V SPRINKLER HEAD, SIDEWALL, PENDENT, NEW V SPRINKLER HEAD, SIDEWALL, UPRIGHT, NEW SPRINKLER HEAD, DRY PENDENT SPRINKLER HEAD, OVER AND UNDER 0 EXISTING SPRINKLER HEADS (TO REMAIN) fe EXISTING SPRINKLER HEADS (REMOVE) )( I FIRE HOSE CABINET FHC FDC Y FIRE DEPARTMENT CONNECTION, WALL TYPE 6FDC,b. FIRE DEPARTMENT CONNECTION, YARD TYPE FDC FIRE DEPARTMENT CONNECTION, FLUSH U FH FIRE HYDRANT - 2 HOSE OUTLET FH FIRE HYDRANT - 2 HOSE OUTLET AND PUMPER CONNECTION ® ASR AUTOMATIC SPRINKLER RISER WMG WATER MOTOR GONG eN ELECTRIC BELL 01 DRY PIPE VALVE ALV ALARM VALVE, WET I1 M MONITOR SWITCH Iil FLOW SWITCH i GC CSC GROOVED COUPLING, GROOVED CAP THRUST BLOCK ---A, PIV POST INDICATOR VALVE, YARD }WIV....X WALL INDICATOR VALVE, PLAN / ELEVATION O HALON SYSTEM AUTOMATIC DISCHARGE STATION A HALON SYSTEM, MANUAL DISCHARGE STATION 1 2 WAY EARTHQUAKE BRACING X4 WAY EARTHQUAKE BRACING CONTROLS EMCS ENERGY MANAGEMENT CONTROL SYSTEM MCC MOTOR CONTROL CENTER MOTOR OPERATOR P PRESSURE TRANSMITTER DIFFERENTIAL PRESSURE TRANSMITTER AP RCU REMOTE CONTROL UNIT Q TEMPERATURE TRANSMITTER © . 0 ■ OPERATOR WITH POSITIVE POSITIONER , FILTER DIFFERENTIAL PRESSURE SENSOR/TRANSMITTER 0 MAIN CONTROL AIR 20 PSIG MECHANICAL LEGE\D 1ST CHARACTER: V = VARIABLE AIR VOLUME TERMINAL UNIT 2ND CHARACTER: F = FAN POWERED UNIT C = SHUTOFF UNIT 3RD CHARACTER: E = ELECTRIC HEAT W = HOT WATER HEAT C = NO HEAT COIL D = DUAL DUCT MARK NUMBER PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED MECHANICAL LEGE ND SYMBOL DESCRIPTION HVAC 24/12 24/12 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 24/12 -\ V < DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST b 241 S 24} ROUND DUCT, NUMBER INDICATES DIAMETER 24/12 } U 24/12i OVAL DUCT, FIRST HUMBER INDICATES MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER x SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS SUPPLY AIR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY EXHAUST, RETURN OR SUPPLY AIR DUCT ROUND , ELBOW FACING TOWARDS EXHAUST, RETURN OR SUPPLY DUCT, ROUND, ELBOW FACING AWAY EXHAUST AIR OR RETURN AIR DUCT SQUARE OR RECTANGULAR, ELBOW FACING TOWARDS L EXHAUST AIR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW FACING AWAY -f=c[-4i TRANSITION RECTANGULAR TO RECTANGULAR TRANSITION AT TAKE OFF TRANSITION SQUARE OR RECTANGULAR TO ROUND OR OVAL UP DOWN DUCT OFFSET UP OR DOWN OPPOSED BLADE DAMPER PARALLEL BLADE DAMPER VOLUME DAMPER DUCT DAMPER, MOTOR OPERATED (ELECTRIC OR PNEUMATIC) BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) AD OR AP ACCESS DOOR (AD) OR ACCESS PANEL (AP) 1 IFD 1FD 1 FIRE DAMPER ( 1 HOUR ) f FD2 FD2 f FIRE DAMPER ( 2 HOUR ) RECTANGULAR DUCT, SQUARE ELBOW WITH TURNING VANES RECTANGULAR DUCT, RADIUS VANED ELBOW EXTRACTION GRID CO SENSOR CO2 SENSOR MECHANICAL LEGE\D DUCT CONNECTION TFLEXIBLE SIDEWALL SUPPLY AIR DIFFUSER, GRILLE, REGISTER AND CFM AIR FLOW t-1 100OR SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER AND AIR FLOW 100 CFM SCREENED OPENING AND CFM AIR FLOW iL 100A FM SUPPLY OUTLET, CEILING TYPE, DIFFUSER OR GRILLE, SQUARE OR RECTANGULAR AND CFM AIR FLOW (SEE NOTE 4) - -1I --n,-► ill,. - II JI 400 CFM IL SUPPLY OUTLET, CEILING TYPE, ROUND AND CFM AIR FLOW (SEE NOTE 4) MI 410 CFM LINEAR DIFFUSER AND CFM AIR FLOW (SEE NOTE 4) r _ - - 1 100 CFM RETURN/EXHAUST REGISTER OR GRILLE, CEILING DUCT TYPE AND CFM AIR FLOW 11 I��i_ - J 100 CFM RETURN/RELIEF GRILLE, CEILING TYPE, NON -DUCTED ' `-'� i [ -A' UNIT HEATER, HORIZONTAL F UNIT HEATER, VERTICAL PROJECTION SUPPLY AIR FLOW DIRECTION RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION ___N___m` O THERMOSTAT, WALL ON NIGHT THERMOSTAT T THERMOSTAT, CEILING R THERMOSTAT, REMOTE, CEILING QH HUMIDISTAT, WALL H HUMIDISTAT CEILING D DUCT TYPE SMOKE DETECTOR 4 D DUCT TYPE HEAT DETECTOR PSTATIC PRESSURE REGULATOR T H TEMPERATURE SENSOR , HUMIDITY SENSOR, DUCT MOUNTED LINED DUCT 1F ATTENUATOR EESOUND EF CENTRIFUGAL FAN Gi CENTRIFUGAL FAN, INLET GUIDE VANES =:= FLEXIBLE DUCT i't4 - -1Mi FSi consulting engineers Seattle, Washington SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACAL/ASIC LAB RELOCATION 12787 SAZAN/SS 07.12.12 RECORD DRAWING 12787 SAZAN/SS 08.13.13 A UT17 AND H3 SERVER MIGRATION W5723449 FSi AWL 05.15.18 05.15.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE D Solutions & Service RAWN SUBTITLE DATE CHECKED ISSUED FOR PERMIT MAY 15, 2018 RIVIE1; t'ED r=OR CODE COMPLIANCE APPROVED MAY 252018 City of Tukwila BUILDING DIVISION CITY OF TUKWILA MAY 222018 PERMIT CENTER MECHANICAL LEGEND CURRENT REVISION W5723449 SYMBOL A DATE 05.15.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER UT17 AND H3 SERVER MIGRATION BUILDING 09-53 DEV. CENTER, WA SHEET MOB M2 JOB NO. 12787 COMP NO. DWG NO. 09-053—MOB SICNBD LEGE\D 3/4"CD FROM CR3BB6, FOR CONTINUATION SEE 1M114 1 /2"CW TO CR3BB6, FOR CONTINUATION SEE 1M114 POC (E)3/4" 1 /2"CW F- w w U) LU w LU J U F- 1 /2"CW TO CR2BB6 CR2BB6, FOR DIAGRAM, SEE 2"ID UP TO FD-2 PIPING 1M113 M504 2"ID LP TO FD-2 1M11 M500 /AC \ 1CC4 ®H®HH 1" 1" ❑O FD-2 2"V UP —� \H ,-2"SAN UP CAP 1 "AIR & 2 FOR FUTURE PH 1 "AIR UP 6" DIRT LE AT BOTTOM 3"CW UP W SE Iv FD-2 EARTHQUAKE �'B�ACING (TYP) FOR CONTINUATION SEE SHEET M103 1/2 HW 3"SAN 2"V 1 /2"CW L F RST FLCOPLA\ \OATH SCALE: 1 /8"=1'-0" L_ 2"SAN TO FD- 3 4 T T —1 I 2„W A-r- F'--r- IT T-1 I I I I I I I l/II_I_ _ L — L_ J "\--2'' UP TO FD-2 2"V UP 2"SAN DN H PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED H TS DOWN OFD UP 6"STS UP 3"V UP 3" VENT UNDER RAISED FLOOR C SEE DETAIL 9 1 M1.13._LNA501 3"V DOWN, FOR CONTINUATION SEE SHEET UGM111 BB AA. 5 FSi consulting engineers Seattle, Washington Solutions & Service 8 REVIEWED t= O IR CODE COMPLIANCE APPROVED MAY 252018 City of Tukwila BUILDING DIVISION CITY OF TUKWILA AY222013 PERMIT CENTER 0 2 4 16 SCALE: 1/8" = 1'-0" ISSUED FOR PERMIT MAY 15, 2018 GE\ E�AL \ 3TES PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION; 1" AIR, 3/4"CW. © 1" AIR DROP. SEE DETAIL TYP M501 FOR SHIELDING SEE SHEET A517. TERMINATE ROOF OVERFLOW DRAIN ABOUT 2 FT. ABOVE FINISHED GRADE WITH WELDED MITERED ELBOW. PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION. 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. GENERAL NOTES ON SHEET M2 SHALL APPLY. ' EFEE\CE .3AWI \GS CO\ STRU CTI O\ \OTES: PROVIDE CONDENSATE DRAIN LINE ROUTED BELOW RAISED FLOOR, WITH AIR GAP TO FLOOR DRAIN. PROVIDE ISOLATION VALVE AND 1/2" CW CONNECTION FOR UNIT HUMIDIFIER. CONNECT TO 3/4" CW. PROVIDE TRAP SEAL ON (E) FD-2 AND FD-2A. MANUFACTURE TO BE SURE SEAL OR EQUAL. MATCH EXISTING DRAIN SIZE. TRAP SEAL PRIMERS No form of trap that depends for its seal upon the action of movable parts shall be used. Each fixture trap shall have a liquid seal...and shall be protected from freezing. Floor drain or similar traps directly connected to the drainage system and subject to infrequent use shall be protected with a trap seal primer. Trap seal primers shall be directly connected to the water supply and shall be accessible for maintenance. (2015 UPC 1005.0, 1006.0 & 1007.0) mO ®a ®®®®O OO EXIS TIN G BLDG 9-53 KEY PLAN NOT TO SCALE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A REVISED ID AND SAN SYSTEMS B R1 LAB REVISION MJC /DM MJC KMR /LL KMR /LL 6.25.90 F DEVELOPMENT LAB — RECORD SET 9-12061 WH GV 02.14.14 9.7.90 G UT17 AND H3 SERVER MITIGATION W5723449 FSi AWL 05.15.18 REVISED FLOOR DRAIN VENTS MJC KMR /LL 9.20.90 D MOVED PIPES FROM STAIRWAY MJC KMR /LL 10.25.90 E RECORD DRAWING MJC KMR /RB 8.30.91 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M.CAUNITIS DATE APPROVED BY DEPT. DATE CHECKED D.MEYER ENGINEER SUBTITLE FIRST FLOOR PLUMBING - NORTH CURRENT REVISION W5723449 SYMBOL DATE 05.15.18 W.HENCKEL CHECKED K.RAMSEY APPROVED K.RAMSEY APPROVED L. LAW 5.17.90 TITLE MECHANICAL MASTER UT17 AND H3 SERVER MITIGATION BUILDING 9-53.1 COL. A—CC/1-6 DEV. CENTER, WA SHEET 1M113 M10 JOB NO. 9-12061 COMP NO. DWG NO. 9-53.1-1M113 SICNSD SYM 1 /2" o HILTI KWIK BOLT II MIN EMBED 3 1 /2" (INTO EXIST CONCRETE), TYP FOR BASE PLATE DETAIL, SEE/ 3 M505 M505 REVISION - DEVELOPMENT LAB - RECORD SET A UT17 AND H3 SERVER MIGRATION 9-12061 W5723449 BY WH FSi 1/2" FULL PORT BALL VALVE, WITH CAPPED HOSE CONNECTION APPROVED GV AWL DATE 02.14.14 05.15.18 SYM REVISION ALL PIPE PENETRATIONS SHALL BE SEALED AIRTIGHT 1/4 V A36 STEEL PLATE PIPE INSULATION (TYP) BY APPROVED 1-3/8"RL 1-3/8"RL 1-3/8"RS 1-3/8"RS DATE PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 05.15.18 S10NBD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DATE FSi consulting engineers Seattle, Washington Solutions (Sc Service DRAWN CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE BASE PLATES SHALL BE POSITIONED ON THE NEW EQUIPMENT PAD. POSITION THE PLATES SUCH THAT THE CENTER OF THE PLATES IS AT LEAST 9 INCH FROM THE EDGE OF THE PAD. �-3/4" DRAIN VALVE (TYP OF 2) ,<.---1-1 /2" GRAVITY CONDENSATE DRAIN ISSUED FOR PERMIT MAY 15, 2018 DETAILS - MECHANICAL INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA 2-1/2 BALANCING VALVE 3" BALL VALVE REVIEV EI) FOR CODE COMPLIANCE APPROvE.D City. of Tukwila BUILDING DIVISION CURRENT REVISION W5723449 SHEET JOB NO. DWG NO. MAY 2 2 2018 P HMIT CENTER SYMBOL A M505 9-12061 DATE 05.15.18 M19 COMP NO. 9-53.1—M505