Loading...
HomeMy WebLinkAboutPermit PG18-0074 - NATERA - INSTALL EMERGENCY EYEWASH, MOP SINK AND UTILITY SINK ALONG WITH 2 WATER HEATERSNATERA 3215 S 116TH ST 109 EXPIRED 07/14/2019 PGI 8-0074 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT 0923049066 3215 S 116TH ST 109 Project Name: NATERA Permit Number: PG18-0074 Issue Date: 6/27/2018 Permit Expires On: 12/24/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 AMANDA MOORE 11621 E MARGINAL WAY S , TUKWILA, WA, 98168 P S F MECHANICAL INC 11621 E MARGINAL WAY S SUITE A , TUKWILA, WA, 98168-1965 PSFMEI*090NZ Phone: (206) 812-7683 Phone: (206) 764-9663 Expiration Date: 10/5/2018 DESCRIPTION OF WORK: INSTALL EMERGENCY EYEWASH, MOP SINK AND UTILITY SINK ALONG WITH 2 WATER HEATERS Valuation of Work: $10,000.00 Water District: TUKWILA Sewer District: VALLEY VIEW Fees Collected: $342.80 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: `;1-7-{� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to the conditions attached to this permit. Signatu Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: "'PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: AH pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line; (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK C 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. le -NC671/ Date Application Accepted: Date Application Expires: ?—"M 0 (For office use pnly) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 3215 South 116th St Natera King Co Assessor's Tax No.: 0923049066 Suite Number: PROPERTY OWNER Name: Amanda Moore Name: E Property Tax Inc Dept City:State: WA Zip: Seattle98168 Address: PO Box 4900 Email: permits@psfmech.com City: Scottsdale State: AZ zip' 85261 CONTACT PERSON — person receiving all project toniaramication Name: Amanda Moore Address: 11621 E Marginal Way S City:State: WA Zip: Seattle98168 Phone: (206) 812-7683 Fax: Email: permits@psfmech.com Floor: New Tenant: 9 Yes WI „No PLUMBING CONTRACTOR INFORMATION Company Name: PSF Mechanical, Inc. Address: 11621 E Marginal Way S City: Seattle State: WA Zip: 98168 Phone: (206) 812-7683 Fax: (206) 762-8381 Date: Contr Reg No.: PSFMEI*090NZ Exp 10/05/2019 Tukwila Business License No.: BUS -0996384 Valuation of Project (contractor's bid price): $ 10,000 Scope of Work (please provide detailed information): Install Emergency eyewash, mop sink and utility sink. Qv -4 a_ Wctst-o" k-ewlYK-) Building Use (per Int'l Building Code). Commercial Occupancy (per Int'l Building Code): Group B Utility Purveyor: Water: Tukwila Sewer. Tukwila Sewer Service HAApplicationsWorms-AppIleations On Lim:11011 ApplicationsTlumbing Permit Application Revised 8-9-114ocx Revised: August 2011 bh Page 1 of 2 r1 11 �1 �J Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 1 Shower, single head trap Sinks 2 Rain water system — per drain (inside building) 2 Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (l-5) 1 Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 1 1 Lavatory Urinal Water heater and/or vent 2 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 1 T APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 1 1 Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets 1 Wash 3 Fixture Type Qty 1 Dental unit, cuspidor Floor drain 1 1 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Emergency Eye 1 Wash Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by Limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Off► 2gOZED AGENT: Signaturef — ` Date: (.0114 10" Print Name: Mailing Address: 1621 E Marginal Way S, Suite A H:\Applications\Forms-Applications On Line\2011 Applications'Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Day Telephone: (206) 812-7683 Seattle WA 98168 City State zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $68.83 PG18-0074 Address: 3215 5 116TH ST 109 Apn: 0923049066 $68.83 Credit Card Fee $2,00 Credit Card Fee R000.369.908.00.00 0.00 $2.00 PLUMBING $66.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R15986 R000.345.830.00.00 1.00 $66.83 $68.83 Date Paid: Thursday, December 06, 2018 Paid By: AMANDA MOORE Pay Method: CREDIT CARD 309103 Printed: Thursday, December 06, 2018 2:37 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT ( QUANTITY PAID $2,292.96 M18-0070 Address: 3215 S 116TH ST 109 Apn: 0923049066 $1,950.16 Credit Card Fee $56.80 Credit Card Fee R000.369.908.00.00 0.00 $56.80 MECHANICAL $1,820.54 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $1,423.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $364.11 TECHNOLOGY FEE $72.82 TECHNOLOGY FEE R000.322.900.04.00 0.00 $72.82 PG18-0074 Address: 3215 S 116TH ST 109 Apn: 0923049066 $342.80 Credit Card Fee $9.98 Credit Card Fee I R000.369.908.00.00 I 0.00 $9.98 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 PLUMBING $195.71 PERMIT FEE R000.322.100.00.00 0.00 $123.42 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $39.14 TECHNOLOGY FEE $12.80 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14635 R000.322.900.04.00 0.00 I $12.80 $2,292.96 Date Paid: Monday, June 04, 2018 Paid By: AMANDA MOORE Pay Method: CREDIT CARD 693892 Printed: Monday, June 04, 2018 3:16 PM 1 of 1 CRIAVSYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 12/06/2018 02:36:54 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********5490 K TRAN AMOUNT: $68.83 APPROVAL CD: 309103 RECORD #: 000 CLERK ID: jazzel X (CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you) Merchant Copy Page 1 of 2 https://classic.convergepay.comNirtualMerchant/transaction.do?dispatchMethod=printTra... 12/6/2018 Awkw.‘ "nwe' CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 12/06/2018 02:36:54 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********5490 TRAN AMOUNT: $68.83 APPROVAL CD: 309103 RECORD #: 000 CLERK ID: jazzel Thank you! Customer Copy Page 2 of 2 https://classic.convergepay.cotn/VirtualMerchant/transaction.do?dispatchMethod—printTra... 12/6/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: N 4--711944 Type of Inspection: ‘615 Prnitt Address: Date Date Called: Special Instructions: 9 Date Wanted: / V i'./, in. p.m. Requester: Phone No: zoo k3q 1 itt pproved per applicable codes. 0 Corrections required prior to approval. MMENTS: it fivb Inspector: Date: — REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 No& ocivt Project: Type of Inspection: Address: 06 321$ 3 ,/41"i-7 Avf Date Called: Special Instructions: iti5 i044.4 41-0 . Date Wanted: /212-163 oti p.m. Requester: No: Phone No: af• 3fL 664o EJApprovedper applicable codes. orrections COMMENTS: Avilafri4 4--c- j0012Y-f 44fs ae-- a-viy /A--,1eetz,0 6/1 rpm,' 15- /9Lcc(45 e.044 sile)1C (4. Date: 1--7--. REINSPEOT1DN FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 418 47 7'f INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: A/A—Ikett Type of Inspection: j )i' 1SM•t Atliar $ fr;:; Address: 52J‘ S• i/647.7- AriP Date Called: Special Instructions: Date Wanted: / 2 - q/g m,. p.m. Requester: Phone No: ElApproved per applicable codes. corrections required prior to approval. COMMENTS: per' Ai i4--lekebmp1 wr- /4cc4/ :t$ An,v e-xrS 4 L Dte p14144fa Ey'lp � (u Inspector: 3(9 Dater Z067 C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit P4L boll+ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Allisz2A Type of Inspection: 1� ?if J4 -T-..l Addre3z's S. //6 � rri : Date Cal ed: Special Instructions: , ro9 Date Wanted: 1�#1.1-/f5 r " p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: P �A' ii4 - m0/ 64S/> InspectorVi) C REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD in/no Retain a copy with permit For0-007 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3f70 Permit Inspection Request Line (206) 438-9350 Project: Tvf Inspection: LtAxyllpin9, Fisiihtt- Address: 3Z/S- 16. is, Date Called: .S. Special Instructions: *I- 109Requester: Date Wanted: /0 —31— 20/9 a. P• • Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 4. tr StAk_ iiiCt/JA-st-f igP Pc1) rlOP 514L Inspector:3o Date: t8 LJ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projecv. NOvierr4- 1p of Inspection: Z -A) KAAAP-lAr.- Address: 32/5- S. lllo 554- -Iv! Special Instructions: Date Wanted: a.m. Requester i) t< all'et(d' Phone No: Ze" - 76:3- 8378 NAApproved per applicable codes. El Corrections required prior to approval. COMMENTS: (tit) hii4 Inspectota)Lf) Date: 9_zo_ziozi,./ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. a INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:T /)o hr.4 of Inspection: i t, Address: / 32/6 So //6 Swift .iof Date Cal Special Instructions: l Dq Date Wanted: a.m g-/b-Zors(� Requester: reel ri 9 Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: R/ciAvvLi%w y,- cl- , ll, Sri (Al)/ pa,* La-akth, Sir,<_ aj e‘de''' care_ Inspector: -E'� ��,�r ,4 � n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 5/31/2019 City of Tukwila Department of Community Development AMANDA MOORE 11621 E MARGINAL WAY S TUKWILA, WA 98168 RE: Permit No. PG 18-0074 NATERA 3215S116ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/14/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress_ -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/14/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sinperely, Ctatt-al -61 Kdace Nichols Permit Technician File No: PG18-0074 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0074 PROJECT NAME: NATERA SITE ADDRESS: 3215 S 116 ST Original Plan Submittal Response to Correction Letter # DATE: 11/28/18 Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: Building Division 11 .3s Public Works Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 12/04/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 1/01/19 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0074 PROJECT NAME: NATERA SITE ADDRESS: 3215 S 116 ST X Original Plan Submittal Response to Correction Letter # DATE: 06/04/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT )WC Building Division .1 ik \ ublic Works Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable E (no approval/review required) Planning Division Permit Coordinator • DATE: 06/05/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/03/18 Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INIT ALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping D PW D Staff Initials: 12/18/2013 PROJECT NAME: kk k SITE ADDRESS: 3)-15 S 1(o £d -- PERMIT NO: "T& 16— do 7 Li ORIGINAL ISSUE DATE: (Q- -7-y fi REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: C. P tot c p ire & f Z�1 Received by: /1/V,Or%ei REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Date: 11/29/2018 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: PG18-0074 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # x❑ Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Natera Project Address: 3215 South 116th St Contact Person: Amanda Moore Phone Number: 206-812-7683 Summary of Revision: Pine sizing changes for gas piping. RECEIVED CITY Of TUKWILA. NOV 2 8 2018 PERMIT CENTER Sheet Number(s): P11-02, P21-01 "Cloud" or highlight all areas of revision including date of revi ion Received at the City of Tukwila Permit Center by: T Entered in TRAKiT on tk)-C1-1 S W:\Permit Center\Templates\Forms \Revision Submittal Form.doc Revised: August 2015 P S F MECHANICAL INC Page 1 of 3 Home Espanol Contact Search L&I AZ Index Help Safety & Health Claims & Insurance Workplace Rights Washington State Department of Labor & Industries P S F MECHANICAL INC Owner or tradesperson Principals REYNOLDS, JAMES P, PRESIDENT READ, ANDREW A, PRESIDENT BEARDSLEY, WARREN SCOTT, SECRETARY CRITCHLOW, JAMES D (End: 09/27/2011) Doing business as P S F MECHANICAL INC WA UBI No 601 318 369 11621 E Marginal Way $ Suite A SEATTLE, WA 98168 206-764-9663 KING County Business type Corporation Governing persons WARREN BEARDSLEY JOHN P KING; CHRISTOPHER J LAWSON; DOUGLAS 0 LONG; ANDREW AARON READ; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PSFMEI"090NZ Effective — expiration 08/09/1991— 10/05/2019 Bond Travelers Cas & Surety Co Bond account no 105975899q $12,000.00 Received by L&I Effective date 03/13/2014 03/13/2014 Expiration date Until Canceled Bond history Insurance Liberty Mutual Fire Insurance Policy no TBZ91452741027 $1,000,000.00 SEARCH My IAA Trades & Licensing Help us improve httos://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 6/27/2018 P S F MECHANICAL INC Received by L&I 09/28/2017 AmPic Effective date 10/01/2017 Expiration date 10/01/2018 Insurance history Savings ...................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ........_....................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 848,535-00 ......._......._...... Doing business as PSF MECHANICAL INC Estimated workers reported Quarter 1 of Year 2018 "Greater than 100 Workers" L&I account contact T3 / KAYLENE MONIER (360)902-6627 - Email: BRKB235@lni.wa.gov Track this contractor A Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid ...................................................................................... No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/10/2014 Inspection no. 317399160 Location 932214 Avenue S Seattle, WA 98108 Inspection results date 04/01/2013 Inspection no. 316732031 Location 600 University Seattle, WA 98101 Violations No violations Page 2 of 3 <, Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601318369&LIC=PSFMEI*090NZ&SAW= 6/27/2018 4 3 2 1 5/15/2018 9:18:59 AM IUD. 5111 4 I ii 20t`. 3 I / 4 LUNCH ,T63,/! XI TIN . G=S vIE DEMO EXISTING GASMETER. NEW ONE TO BE PROVIDED. _._2'G, 61N W;c NATURAL GAS PIPE TO -� GAS METER. GAS METER PROVIDED R.ggl .. 588 MBH'CAPACITY.........__5 NTRAL OFIICE / / / / IEi_. /, / // / / CR-1 `. f..._... •PA /,//� JS-1) 314"Cw {?PEKE' F ELD VERIFY L:0 ION. / 2" PEC (y XISTING/OSTE N LIN ' I ,VERIFf LOCATION.'./ . FIELD VERIFY REPLACEMENT OF EXISTING 2"G __CONTINUATION OF EXISTING GAS 1 _ LINE TO EXISTING EQUIPMENT ................ 3/4"CW VESTIBULE •.'Qr• '•Y"O t. PW UP TO ROOF 1.1/2'V P TO ROOF 1/2"CW DN TO S-1 AND EWH-2 ELEC COM tit CLOSET 123 j/ i // r///// /'// OFFiC'// LAZE OLEVEL 1 PLUMBING PLAN 0' 2' 4' 8' SCALE: 1/8" =11-0" 2 OFFICE, €...... _ 10 9........' D WING NOTES: 1 . CONNECT NEW JS-1 TO EXISTING 12 GAL ELEC HOT WATER HEATER ON EQUIPMENT MEZZANINE. SERVES CURRENT RR & KITCHEN SINK <A> B REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 5 2018 City of Tukwila UILDING DIVISION REVOON NO.LL. RECEIVED CITY OF TUKWILA NOV 2 8 2018 PERMIT CENTER A PERKI N S +WI.L L 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com ° p�F PSFMechanical= PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764,9663 www.psfmechanical.com PROJECT natera® Conceive.. Deliver. Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 EXPIRES: 07/21/19 ISSUE CHART MARK ISSUE DATE /off PERMIT SET 06/01/18 A PERMIT CORRECTION 06/16/18 4\ PERMIT CORRECTION 07/31/18 PERMIT REVISION 11/27/18 Job Number 7056 Drawn RH Checked MG Approved LP TITLE LEVEL 1 PLUMBING PLAN SHEET NUMBER P11-02 1 4 3 n:\projects\IocaI13215 south 116th street\7056 - 3212 tukwila natera evercord ti\cad\plot dwgs\7056psf-p2101.dwg 5/15/2018 9:18:59 AM SB 1(42") SIZE VARIES 1-1/2"W TO S-1 2"PW � 2"V ACCESS COVER 12" GATE VALVE SUMP PUMP I I POWER WIRING BY E.C. ll 0 0 0 t CHECK VALVE SUMP PUMP "ALARM" FLOA1 6" "LAG PUMP ON' FLOAT - 6" BOTH PUMPS EVERGIZED. "LAG PUMP ON' FLOAT - (LEAD PUMP ALTERNATES) SIZE (3") SP-1 VARIES 14" PUMP STOP FLOAT . •a a 4 .a a •4 a A • a • FIBERGLASS BASIN. a ' SEE SCHEDULE. a d' 4 a . 4 NOTES: SUMP PUMP AND BASIN ARE A FACTORY SUMP PUMP AND BASIN SYSTEM. 2 SP-1, SP-2 & SB-1 SEWAGE SUMP PUMP DETAIL. P21-01 SCALE: NTS 4 I 3 'JUL 1.`i 2fl 2 SINK FAUCET 1/2"HW -f ( S-1 ) UNDERSINK WATER HEATER. -/( ATTACH HEATER TO WALL. 1/2"CW BALL VALVE (TYP.) 1-112"V UP TO ROOF If 1-112"W TO SUMP PUMP BASIN. SEE P11-02 FOR LOCATION. 'JUL 2819. NOTES: SEE PLUMBING FIXTURE SCHEDULE FOR MODEL NUMBER AND SIZE OF SINK. FOR OPTIMUM PERFORMANCE, MOUNTING LOCATION SHOULD BE LOCATED WITHIN 2 FEET OF SINK. UNDER SINK INSTANTANEOUS ELECTRIC WATER HEATER P21-01 SCALE: NTS GAS METER 888 MBH 6 IN. W.C. n GAS PIPING LAYOUT P21-01 SCALE: NTS UPDATED GAS PIPE SIZING 2 I T T T rT T — T T 1.1/2"G 1-112"G 1-1/2"G 1-1/4"G NOTES: 1. GAS PIPE SIZING BASED ON 2015 INTERNATIONAL FUEL GAS CODE TABLE METALLIC GAS PIPE AT 6 IN W.C. INLET PRESSURE. 2. CALCULATIONS AND SIZING PERFORMED PER 2015 IFGC SECTION 402.4.1 LENGHT OF 125 FT. 3. PIPE CONNECTIONS FOR 2" AND UP ARE WELDED; PIPE CONNECTIONS 1-1/2" ARE THREADED. 4. FIELD VERIFY POINT OF CONNECTIONS TO EXISTING EQUIPMENT. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 052018 City of Tukwila BUILDING DIVISION 402.4, SCHEDULE 40 WITH THE LONGEST AND DOWN RECEIVED CITY OF TUKWILA NOV 28 2018 PERMIT CENTER 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com SFMechanicaN PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764.9663 www.psfinechanical.com PROJECT Conceive. Deliver% Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 EXPIRES: 07/21/19 ISSUE CHART MARK ISSUE DATE A\ PERMIT SET 06/01/18 A\ PERMIT CORRECTION 06/16/18 A\ PERMIT CORRECTION 07/31/18 A\ PERMIT REVISION 11/27/18 Job Number 7056 Checked Approved TITLE PLUMBING DETAILS SHEET NUMBER 0 9- 0.. (0 0 0 0. a 0 0 (1) 0 N co in ti a) 0 CD 0 0) N M 0 0 17) 0 0 5/15/2018 9:18:59 AM PIPING SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION AC AAV AFF HCAAV MAV AG BFG BFV BV BLCV ABLCV BW BWWS CD CKV CO FD RD OFD DPS DCKV/RPBV DOF FF FCB FCR FCO FS FU GCKV GV GLV HB HR DV AIR COMPRESSOR AIR VENT - AUTO ABOVE FINISHED FLOOR AIR VENT - AUTO (HIGH CAPACITY) MANUAL AIR VENT ALIGNMENT GUIDE BELOW FINISHED GRADE BUTTERFLY VALVE ' BALL VALVE BALANCING VALVE BALANCING VALVE (AUTOMATIC) BULB WELL BULB WELL WITH SENSOR CANOPY DRAIN CHECK VALVE CLEANOUT DECK; PLANTER OR FLOOR DRAIN DRAIN - FLOOR DRAIN - ROOF DRAIN - ROOF OVERFLOW DIFFERENTIAL PRESSURE SWITCH DOUBLE CHECK VALVE ASSEMBLY/ REDUCED PRESSURE BACKFLOW PREVENTER DIRECTION OF FLOW FLANGE FITTING FLEX CONNECTOR (BRAIDED) FLEX CONNECTION (RUBBER) FLOOR CLEANOUT FLOW SWITCH FUNNEL GAS CHECK VALVE GATE VALVE GLOBE VALVE HOSE BIBB HOSE REEL HOSE END DRAIN VALVE T P/T PT PA PC PPD PV PTRV P PSD PG DPG PRV RV RPBP CR ER RD SA SLV SQ. FT. STR TH THWT 3WCV TPV TDV 2WCV UN VTR VFM WCO WH PETE'S PLUG PIPE ANCHOR PIPE CAP PIPES DOWN PIPES UP PIPE PITCHED DOWN IN DIRECTION OF ARROW PLUG VALVE PRESSURE TEMPERATURE RELIEF VALVE PUMP PUMP SUCTION DIFFUSER PRESSURE GAUGE PRESSURE GAUGE (DOUBLE) PRESSURE REDUCING VALVE PRESSURE RELIEF VALVE REDUCED PRESSURE BACKFLOW PREVENTER REDUCER -CONCENTRIC REDUCER - ECCENTRIC ROOF DRAIN SHOCK ARRESTOR SOLENOID VALVE SQUARE FEET STRAINER THERMOMETER THERMOMETER WITH TRANSMITTER THREE-WAY CONTROL VALVE TRAP PRIMER VALVE TRIPLE DUTY VALVE TWO-WAY CONTROL VALVE UNION VENT THRU ROOF VENTURI FLOWMETER WALL CLEAN OUT WALL HYDRANT x 11 V� ICI I) --FOI 10 ____ 1 o +< III ICI ® PISD Q J 4 NJ P4 + RPBP o MI O -17/ n i oO ® DP -D4-1\ -D4- n 4' nT 4' gi 1 29251 0 I I FCO I° 1 TDV d4 FS Y I1 11.4 D4 fH I-- i D411 PIPE INSULATION SCHEDULE/ PIPING SYSTEM TEMP RANGE THERMAL COND MEAN RAT TEMP INSULATION MATERIAL NOTES <1" 1" TO < 1-112" 1-1/2" TO <4" 4" TO <8" > 8" DOMESTIC COLD ALL 0.21-0.27 75 FIBERGLASS 0.5 0.5 1.0 1.0 1.0 3,4,6 NON -POTABLE COLD ALL 0.21-0.27 75 FIBERGLASS 0.5 0.5 1.0 1.0 1.0 3,4,6 DOMESTIC HOT Z105 0.21-0.28 100 FIBERGLASS 1.0 1.0 1.5 1.5 1.5 3,5,6 STORM DRAIN ALL 0.21-0.27 75 FIBERGLASS 0,5 0.5 1.0 1.0 1.0 2,6 HEATING WATER 105-140 0.21-0.28 100 FIBERGLASS 1.0 1.0 1.5 1.5 1.5 3,5,6 HEATING WATER 141-200 0.25-0.29 125 FIBERGLASS 1.5 1.5 2,0 2.0 2.0 3,5,6 HEATING WATER 201-250 0.27-0.30 150 FIBERGLASS 2.5 2.5 2.5 3.0 3.0 3,5,6 HEATING WATER 251-350 0.29-0.32 200 FIBERGLASS 3.0 4.0 4.5 4.5 4.5 3,5,6 HEATING WATER 450 0.32-0.34 250 FIBERGLASS 4.5 5.0 5.0 5.0 5.0 3,5,6 NOTES: 1 2 3 4 5 6 VALUES PER THE 2015 SEC TABLE C403.2.9 ORL: INSULATE ONLY THE 1ST 15' CLOSEST TO THE DRAIN. RL: INSULATE HORIZONTAL (AND VERTICAL) RAIN LEADER PIPING INSIDE THE BUILDING ENVELOPE WITH 1" INSULATION. DRAIN BODY: INSULATE ALL INSIDE THE BUILDING ENVELOPE. HOT AND COLD PIPES LARGER THAN 2": RIGID INSERTS, INSULATION CONTINUOUS THROUGH THE HANGER, SHEETMETAL SHIELD. COLD PIPES 2" AND SMALLER: RIGID INSERTS, INSULATION CONTINUOUS THROUGH THE HANGER, SHEETMETAL SHIELD. HOT PIPES 2" AND SMALLER: NO RIGID INSERTS, INSULATION NOT CONTINUOUS THROUGH THE HANGER, NO SHEETMETAL SHIELD, JACKETING: METAL JACKET (SEALED WEATHER TIGHT) WILL BE USED AT ALL EXTERIOR INSULATION EXPOSED TO WEATHER (I.E.ROOFTOP PIPING). PVC JACKET WITH RIGID CALCIUM SILICATE INSULATION WILL BE USED ON ALL HORIZONTAL PIPING AT OR NEAR THE FLOOR SUBJECT TO POTENTIAL FOOT TRAFFIC. PVC JACKET WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR ELEVATION (I.E. MECHANICAL ROOMS AND GARAGE HOSE BIBBS). PVC IS RECOMMENDED INSTEAD OF METAL IN EXPOSED AREAS DUE TO ITS RESILIENCY - METAL JACKETS DENT. PLUMBING GENERAL NOTES 1. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES BASED ON NATIONAL, STATE, AND MUNICIPAL LAWS, CODES, REGULATIONS AND ORDINANCES. THIS PROJECT IS DESIGNED SPECIFICALLY BASED ON THE 2012 WASHINGTON STATE PLUMBING CODE AND THE 2012 WASHINGTON STATE ENERGY CODE. 2. FIELD VERIFY ALL DIMENSIONS, HEIGHTS, AND ELEVATIONS OF EXISTING CONDITIONS FRIOR TO STARTING ANY RELATED WOTK. COORDINATE THE EXACT LOCATION OF ALL NEW AND EXISTING PLUMBING AND MECHANICAL EQUIPMENT WITH THE LOCATIONS OF LIGHT FIXTURES, PIPING, CONDUIT, AND OTHER CONSTRUCTION TO ALLOW FOR PROPER ROUTING AND SERVICEACCESS TO EQUIPMENT. 3. WHERE NEW CONSTRUCTION ABUTS EXISTING CONSTRUCTION TO REMAIN, ALL CONDITIONS AFFECTING WORK PROGRESS AND CPNFORMANCE TO PLANS AND SPECIFICATIONS SHXLL BE VERIFIED PRIOR TO START OF WORK, 4. CONFIRM ALL POINTS OF CONNECTION AND FINISHED DIMENSIONS OF ANY NEW EQUIPMENT, WORK OR FURNISHINGS TO BE PROVIDED BY OTHERS AND INSTALLED WITHIN THE SCOPE OF THIS PROJECT. THE SUBCONTRACTOR SHALL PROVIDE ALL NECESSARY CONSTRUCTION STAGING TO COMPLETE THE REQUIREMENTS OF THIS PROJECT. 5. PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET THE FOLLOWING WATER USAGE EFFICIENCY STANDARDS. A. WATER CLOSETS - TANK OR FLUSH VALVE: 1.6 GPF B. URINALS: 1.0 GPF C. LAVATORY FAUCETS: 2.5 GPM C. KITCHEN FAUCETS: 2.5 GPM E. SHOWER HEADS: 2.5 GPM 6. COORDINATE EXACT LOCATIONS, MOUNTING HEIGHTS AND FINAL LOCATIONS OF ALL EXISTING AND NEW PLUMBING FIXTURES WITH ARCHITECTURAL DRAWINGS, BUILDING CONSTRUCTION AND FEATURES, ETC. 7. PLUMBING FIXTURE MOUNTING SHALL COMPLY WITH THE CONTRACT DOCUMENTS ANDTHE WASHINGTON STATE BUILDING CODE - W.A.C. 51-50 - REQUIREMENTS FOR BARRIER -FREE ACCESSIBILITY. 8. ALL CLEANOUTS SHALL BE FULLY COORDINATED WITH EXISTING AND NEW BUILDING FEATURES AND LOCATED WHERE READILY ACCESSIBLE. 9. SINK AND LAVATORY DRAINS SHALL BE CHROME PLATED 17 GA. BRASS TUBING BY ENG'NEERED BRASS, DEARBORN BRASS OR BRASSCRAFT. PROVIDE INSULATED P-TRAP AND SUPPLY COVERS - TRUEBRO OR EQUAL - AT ALL EXPOSED P-TRAPS AND SUPPLIES PER A.D.A. STANDARES. 10. INSTALL WATER HAMMER ARRESTORS ON HOT AND COLD WATER PIPE SYSTEMS AT EACH FIXTURE GROUP AND AT ALL FIXTURES WITH QUICK ACTING VALVES. WATER HAMMMER ARRESTORS SHALL BE EQUAL TO ZURN 'SHOCKROLL'. SELECT UNIT SIZE AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORDANCE WITH PDI STANDARD WH-201. 11. PROVIDE ACCESS PANELS AT ALL WATER HAMMER ARRESTORS AND OTHER EQUIPMENT REQUIRING ACCESS FOR MAINTENANCE OR REPLACEMENT LOCATED ABOVE OR BEHIND GYPSUM WALL BOARD SURFACES. ALL ACCESS PANELS AND DOORS SHALL BE ELMDOR-STONEMAN DW/DWB SERIES, SLK SERIES OR EQUAL. PROVIDE WITH 14 GA DOOR AND FRAME, CYLINDER LOCK, CONTINUOUS PIANO HINGE AND PRIME COATED READY FOR PAINTING. WHERE REQUIRED BY THE SURFACE ASSEMBLY RATING, PROVIDE FIRE RATED ACCESS DOORS OF SIMILAR TYPE, STYLE AND DESIGN SO AS TO MAINTAIN THE INTEGRITY AND RATING DF THE WALL OR CEILING. 12. ALL EQUIPMENT ACCESS PANELS SHALL BE FURNISHED AND INSTALLED BY THE GENERAL CONTRACTOR. TAG iUL'1.4.128 FIXTURE 13. COLD AND HOT WATER PIPING SHALL BE INSULATED AND ROUTED FULL SIZE WITH APPROPRIATE SIZE REDUCTIONS AND INSULATED AT THE POINT OF CONNECTION TO THE FIXTURE. 1/2" COLD WATER LINES LIMITED TO 1' - 0" DISTANCE FROM FIXTURE "DEADLEGS" OR FUTURE STUBS ON ACTIVE POTABLE WATER LINES. DOMESTIC WATER STUBS FOR FUTURE SHALL BE LIMITED TO 4" TO PREVENT STAGNANT WATER CONDITIONS. 14. INSTALL ALL DOMESTIC WATER PIPING ON THE "WARM" SIDE OF BUILDING. SEE DRAWINGS FOR ANY HEAT TRACE REQUIREMENTS. 15. PROVIDE TRAP PRIMERS ON ALL FLOOR DRAINS / FLOOR SINKS EXCEPT IN SHOWER STALLS OR OTHERWISE NOTED ON DRAWINGS. CONTRACTOR SHALL PROVIDE AND INSTALL ACCESS PANELS AT ALL TRAP PRIMERS THAT ARE CONCEALED ABOVE OR BEHIND GWB CEILINGS OR WALLS. 16. COORDINATE ALL WALL MOUNTED DEVICE LOCATIONS WITH ARCHITECTURAL INTERIOR ELEVATIONS. 17. DO NOT RUN ANY PIPES OVER ANY ELECTRICAL PANEL OR SWITCHGEAR. COORDINATE PIPE ROUTING AND FINAL LOCATIONS TO AVOID ELECTRICAL PANELS. 18. PROVIDE MANUFACTURER'S RECOMMENDED AND CODE REQUIRED CLEARANCES AROUND ALL PIECES OF EQUIPMENT. PIPING AND CONDUIT SHALL NOT INTERFERE WITH REQUIRED ACCESS. 19. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 20. EQUIPMENT LAYOUT IS BASED ON EQUIPMENT LISTED IN EQUIPMENT SCHEDULES. ANY OTHER EQUIPMENT USED IS SUBJECT TO MEETING PERFORMANCE REQUIREMENTS OF LISTED EQUIPMENT AND NOT EXCEED WEIGHT AND ELECTRICAL REQUIREMENTS. 21. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2012 MECHANICAL CODE AND BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 22. ALL PLUMBING EQUIPMENT AND PIPING SHALL BE PROVIDED WITH SEISMIC RESTRAINTS IN ACCORDANCE WITH REQUIRED CODES. 23. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 24. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 25. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 26. PROVIDE LINE SIZE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 27. PROVIDE UNION, GROOVED OR FLANGED PIPE CONNECTIONS AS REQUIRED, AT ALL EQUIPMENT FOR SERVICING AND REMOVAL OF EQUIPMENT. 28. FOR ALL CONDENSATE DRAIN TERMINATIONS, PROVIDE A MINIMUM AIRGAP / AIRBREAK HAVING A MINIMUM VERTICAL DISTANCE AS MEASURED FROM THE LOWEST POINT OF THE INDIRECT WASTE LINE TO THE FLOOD RIM OF THE CONDENSATE RECEPTOR OF NOT LESS THAN 1". SEA`; 11\iE PERMIT 12'SIRED FOR: I1d 1' chanioal Electrical 0 Plumbing Gas Piping !!'y of Tukwila DING DIVISION MOUNTING 200 REVISIONS NA changes shall be de to the scope of work rAthout prior approval of Tu!'rwtla Building Division_ RISarws i require a new plan submittal VICINITY MAP SITE PLAN :ri P�cr;a?tUfn K2 Starr: AREA OF WORK Plan review approval is subject to errors and omissions. / p oval cf construction documents does not authorize t; _0 violation of any adopted code or ordinance. Receipt o; approved Fioid Copy and conditions is acknowledged: By: firrj-Le- Date: City of Tukwila BUILDING DIVISION 223300 WATER HEATER SCHEDULE TAG MANUFACTURER/ MODEL# UNIT LOCATION LEVEL GRID TANK CAPACITY ELEMENT (KW) RECOVERY --TEMP RISE °F AMP WEIGHT- LBS ELECTRICAL V/PHIHZ NOTES EWH-1 EEMAX/ EX9OT EE L1 C3 N/A 9 2GPH'@ 31 °F 33 4 277V/1 PH/60HZ EWH-2 EEMAX/ EX9OT LI B1 N/A 9 2GPH'@ 31°F 33 4 277V/1 PH/60HZ NOTES: 1. INSTANT POINT OF USE SUMP BASIN SCHEDULE TAG DESCRIPTION MANUFACTURER / MODEL # LOCATION SERVES VOLUME CAPACITY CU. FT. DIAMETER IN. LENGTH IN. WIDTH IN. HEIGHT IN. WEIGHT (LBS) NOTES SB-1 SUMP BASIN ZOELLER 31-0043 L1 VESTIBULE SINK 15 30 NOTES: 1. INSIDE DIMENSION 2. FIBERGLASS - PROVIDE WITH DUPLEX ACCESSIBLE TOP 3. PRECAST CONCRETE PLUMBING FIXTURE SCHEDULE MANUFACTURER I MODEL # W V HW CW NOTES REVIEWtD FON CODE COMPLIANCE APPROVED J UN 20 2018 IMl 1,2 City of Tukwila BUILDING DIVISION EEW-1 EMERGENCY EYEWASH WALL MOUNTED FIXTURE: GUARDIAN / G1814 SPRAY HEAD: GUARDIAN AP470-001 1.6 GPM VALVE: GAURDIAN AP600-101V 1-1/4" 1" 1/2" STAINLESS STEEL BOWL. TWO GS-PLUS OUTLET HEADS WITH "FLIP TOP" DUST COVER, INTERNAL FLOWCONTROL AND FILTER. CHROME PLATED BRASS STAY -OPEN BALL BALBE WITH FLAG HANDLE. PROVIDE THERMOSTATIC MIXING VALVE GAURDIAN G3600LF JS-1 MOP SINK FREE STANDING SINK: FIAT FL-1 FAUCET: FIAT830 3" 2" 3/4" 3/4" 20-114"x17-1I4"x13" WHITE. COMPRESSION MOLDED STONE. FLOOR MOUNTED WITH WHITE BAKED ENAMEL STEEL LEGS S-1 UTILITY SINK FREE STANDING SINK: FIAT FL-1 FAUCET: FIAT Al 3" 2" 3/4" . 3/4" 20-1/4"x17-114"x13" WHITE. COMPRESSION MOLDED STONE. FLOOR MOUNTED WITH WHITE BAKED ENAMEL STEEL LEGS. CHROME PLATED METAL FAUCET. PUMP SCHEDULE TAG QTY DESCRIPTION MANUFACTURER 1 MODEL # LOCATION SERVES FLOW (GPM) HEAD (FT) HEAD (PSI) MOTOR ELECTRICAL WEIGHT (LBS) NOTES HP TOT. HP RPM FLA MOP E-POWER VOLT 1 PH SP-1 2 VESTIBULE SINK ZOELLER G137 L1 VESTIBULE SINK 10 26 - 1/2 1 1750 - - YES 460 3 48 1,2,3,4,5 NOTES: DISCONNECTS AND STARTERS ARE PROVIDED ON CONTROL PANEL BY M.C. 1. SEE PLAN FOR LOCATION PROVIDE WITH REMOVAL SYSTEMS INCLUDING DISCHARGE FLANGE KIT AND 2' GUIDE RAILS NEMA 4X DUPLEX WELL CONTROL PANEL WITH HIGH WATER ALARM FOR ALL 3' PUMPS 3 4 40 FT POWER/SENSOR CABLES FACTORY PROVIDED FOR CONNECTION BETWEEN PUMPS AND PUMP CONTROLLER BY E.C. FIELD VERIFY REQUIRED LENGTH 5 PROVIDE WITH EXPLOSION PROOF MOTORS DRAWING INDEX RECEIVED CITY OF TUKWILA DWG # P00.01 DESCRIPTION LEGEND, GENERAL NOTES AND SYMBOLS SUN 4 2018 P11-01 LEVEL 1 DEMO PLAN PERMIT CENTER P11.02 LEVEL 1 PLUMBING PLAN P21-01 PLUMBING DETAILS PGI8-- 0 Pi A PERKI N S -WILL 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com PSFMechanical‘i. PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764.9663 www.psfinechanical.com PROJECT natera Conceive. Deliver. Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 EXPIRES: 07/21/19 ISSUE CHART MARK ISSUE PERMIT SET DATE 06/01/18 Job Number 7056 Drawn RH Checked MG Approved LP TITLE LEGEND, GENERAL NOTES, SYMBOLS SHEET NUMBER Poo-01 4 3 2 1 dwgs\7056_psf-p 1100.dwg ukwila natera evercord ti\cad\ t\7056 - 3212 rojects\local\3215 south 116th s 4 L AREAOF WORK 4 J111•0111110 / / / // / / % / ! l,./ / i // CR. / r/ / / / NTRAL RECEIVING 121 EXISTING GAS METER CONTINUATION OF EXISTING GAS LINE TO EXISTING EQUIPMENT CR-1 OLEVEL 1 DEMO PLAN °i SCALE: 1/8" =1'-0" DRAWING NOTES: CR-$ VESTIBULE 122 __ _, ELEC COMM CLOSET RE IEWED FOR COD COMPLIANCE APPROVED JJN 20 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0 4 2018 PER PERK fV S LL 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com PSFMechanicalki PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764.9663 www.psfinechanical.com PROJECT Conceive. Deliver. Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 Job Number Drawn Checked Approved EXPIRES: 07/21/19 ISSUE CHART ISSUE 1 DATE PERMIT SET 06101/18 TITLE LEVEL 1 DEMO PLAN SHEET NUMBER 0 0 4- L_ AOFWORK = ojects\local\3215 south 116th s co co 0 N o ATION NTFtALOF i j 1 of EXISTING GAS METER --..._..1:114"G, 61N: W.0 NATURAL GAS PIPE TO - GAS METER GAS METER PROVIDED BY.- RECEI`,'P$88 MBH CAPACITY.' 121 FIELD VERIFY REPLACEMENT OF EXISTING 1-114"G CONTINUATION OF EXISTING GAS LINE TO EXISTING EQUIPMENT 3/4"CW re R-3 2" P:. CONNECT TO E)SI ING W4STE LINE: FIELD VERIFY CATION.' , 314"CW .,OFFICE ;._......_..__........, ,%�i' %' /aFFICE FIEtib ERIFY LOOXT 0 ./ % DEMO EXISTING GASMETER. NEW ONE TO BE PROVIDED. ELEC COMM CLOSET 23 DR WING NOTES: 1 CONNECT NEW JS-1 TO EXISTING 12 GAL ELEC HOT WATER HEATER ON EQUIPMENT MEZZANINE. SERVES CURRENT RR & KITCHEN SINK 1/2" W DN TO S-1 AND EWH-2 :Lore VIEWED FOR E COMPLIANCE APPROVED JUN 2 0 2018 of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 04 2018 PERMIT CENTER 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com p9F PSFMechanical= PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764.9663 www.psfmechanical.com PROJECT Conceive. Deliver. Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 Job Number Drawn Checked Approved EXPIRES: 07/21/19 ISSUE CHART ISSUE PERMIT SET 06/01/18 7056 RH MG LP TITLE LEVEL I PLUMBING PLAN SHEET NUMBER 4 dwgs17O56_psf-p21O1.dwg as U 0 U I- a) a) ca a) its m N N M 0 ti a) a) 3215 south 116th s rojects\Ioca 5/15/2018 9:18:59 AM r V,, SINK FAUCET (S-1 ) 112"HW -if UNDERSINK WATER HEATER. ATTACH HEATER TO WALL. EZI 0 112"CW BALL VALVE (TYP.) 1-1/2"V UP TO ROOF 1-1/2"WTO SUMP PUMP BASIN. SEE P11-02 FOR LOCATION. NOTES: SEE PLUMBING FIXTURE SCHEDULE FOR MODEL NUMBER AND SIZE OF SINK. FOR OPTIMUM PERFORMANCE, MOUNTING LOCATION SHOULD BE LOCATED WITHIN 2 FEET OF SINK. UNDER SINK INSTANTANEOUS ELECTRIC WATER HEATER P21-01 SCALE: NTS GAS METER 888 MBH 6 IN. W.C. 18' 10 EXISTING GAS UNIT HEATER (200 MPH) re 0 3' 15' °—\' 314"G O `-1-114"G GAS PIPING LAYOUT P21-01 SCALE: NTS CO 0 N 26' i IQ8 10 3/4"G d CO CO 2 Z CO U N CC °—\- 3/4"G 18' 8' 01 IO 6' 1-1/4"G 3I4"G 50' 1"G 1/2"G z O 14' 1 /2"G 0 JUL2Oi NOTES: 1. GAS PIPE SIZING BASED ON 2015 INTERNATIONAL FUEL GAS CODE TABLE 402.4, SCHEDULE 40 METALLIC GAS PIPE AT 6 IN W.C..INLET PRESSURE. 2. CALCULATIONS AND SIZING PERFORMED PER 2015 IFGC SECTION 402.4.1 WITH THE LONGEST LENGHT OF 125 FT. 3. PIPE CONNECTIONS FOR 2" AND UP ARE WELDED; PIPE CO AND DOWN ARE THREADED. • •II ►�,I - / D FOR COMPLIANCE APPROVED JUN 202018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 042018 PERMIT CENTER OMNI A 1301 Fifth Avenue Suite 2300 Seattle, WA 98101 t 206.381.6000 www.perkinswill.com SFMechanicaIa PSF Mechanical, Inc. 11621 E. Marginal Way S, Suite A Seattle, WA 98168 206.764.9663 www.psfmechanical.com PROJECT natera° Conceive. Deliver. Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 EXPIRES: 07/21/19 ISSUE CHART IMARKI ISSUE I DATE I PERMIT SET 06/01/18 Job Number 7056 Drawn RH Checked MG Approved LP TITLE PLUMBING DETAILS SHEET NUMBER