Loading...
HomeMy WebLinkAboutPermit PG18-0077 - IMPACT CHARTER SCHOOL - HAND SINK, GREASE TRAP, DRINKING FOUNTAIN, MOP SINK AND HOT WATER TANKIMPACT CHARTER SCHOOL 3438 S 148T" ST PGI 8-0077 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: htto://vvww.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT. 0040001025 Permit Number: PG18-0077 3438 S 148TH ST Project Name: IMPACT CHARTER SCHOOL Issue Date: 7/11/2018 Permit Expires On: 1/7/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOKA GAKKAI INTERNATIONAL 3438 S 148TH , SEATTLE, WA, 98168 STEVE CARNEY 8706 S 222ND ST, KENT, WA, 98031 STATE MECHANICAL COMPANY 8706 S 222ND ST, KENT, WA, 98031 STATEMC141C7 Phone: (206) 575-7527 Phone: (206) 575-7527 Expiration Date: 9/1/2019 DESCRIPTION OF WORK: TO PLUMB AND INSTALL: 1 HAND SINK, 1 - 3 COMP SINK, 1 GREASE TRAP, 1 DRINKING FOUNTAIN, 1 MOP SINK & 1 HOT WATER TANK, Valuation of Work: $14,980,00 Water District: 125 Sewer District: VALLEY VIEW Fees Collected: $203.54 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit nd agre to the conditions attached to this permit. Signature: Date: 7 Print Na (b2�zi7 (get? W1 "4' , This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No.. Date Application Accepted: 0' /rifle Date Application Expires: 1 a�l (( IS -0077 (Far office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3438 South 148th St Tenant Name: Impact Charter School PROPERTY OWNER Name: Steve Carney Name: 3400 S 148TH STREET LLC Address: 8706 S 222nd St Address: 3438 S 148TH ST City:Kent State: WA City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Steve Carney Address: 8706 S 222nd St Address: 8706 S 222nd St Phone: (206) 575-7527 Fax: (206) 575-7529 City:Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Email: stevec@statemech.net King Co Assessor's Tax No.:0040001025 Suite Number: Floor: 1 New Tenant: 0 Yes ❑..No PLUMBING CONTRACTOR INFORMATION' Company Name: State Mechanical Co Address: 8706 S 222nd St City: Kent State: WA Zip: 98031 Phone: (206) 575-7527 Fax: (206) 575-7529 Contr Reg No.: STATEMC 141 C7 Exp Date: 09/01/2019 Tukwila Business License No.: BUS -0101359 Valuation of Project (contractor's bid price): $ 14,980 Scope of Work (please provide detailed information): To plumb and install: 1 Hand sink, 1: 3 Comp sink, 1 Grease trap, 1Drinking fountain, 1 Mop sink & 1 Hot water tank Building Use (per Int'l Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: H: Applicat ons\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Sewer Page I of 2 • Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 1 Shower, single head trap Sinks 3 Rain water system — per drain (inside building) 1 Grease interceptor for commercial kitchen (>750 gallon capacity) -y�y Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 1 Lavatory Urinal Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: _2. z4 i Date: 06/11/2018 Print Name: Steve Camey Mailing Address: 8706 S 222nd St H:\ApplicationsTorns-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8-9-11.docs Rcviscd: August 2011 bh Day Telephone: (206) 575-7527 Kent WA 98031 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS 1 ACCOUNT PerrnitTRAK QUANTITY PAID $203.54 PG18-0077 Address: 3438 S 148TH ST Apn: 0040001025 $203.54 PLUMBING $195.71 PERMIT FEE R000.322.100.00.00 0.00 $123.42 PERMIT ISSUANCE BASE FEE R000.322,100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $39.14 TECHNOLOGY FEE $7.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14694 R000.322.900.04.00 0.00 $7.83 $203.54 Date Paid: Monday, June 11, 2018 Paid By: STATE MECHANICAL CO Pay Method: CHECK 12982 Printed: Monday, June 11, 2018 1:59 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Writ. °10077 Project: /m T eH tvr,i4 Type of Inspection: t fLU$ Y r FINAL. Address: 33138 0$ / * S/-. Date Called: Special Instructions: Date Wanted: 8-/ 7-48p.m. a Requester: Phone No: pproved per applicable codes. tl Corrections required prior to approval. COMMENTS: �k- f Ow-811`IG- F71•111-1---- Inspector: '/1 ,1 -1 ---- Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION XES-007 7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: frif#Ver-e/73"27ZR ftli- Type of Inspection: Address: 5/c9A S, ''&7/L 6777 Date Called: Special Instructions: AO/i$#-"/N "5/NG- Date Wanted: -1—/ .5 -/g a. . P. • Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 29/)<-- attig/HG— V/VPOR 036 a) f)4,a44 8 G.- Rt)G-11 Inspector: Date: 7-0-18 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali, to schedule reinspection. GB2 FILE 35/50 GPM grease interceptor Specification and Submittal 35" 23" (58 cm) (89 cm) 5" (13 cm) 13-3/4" (35 cm) 8-3/4" (22 cm) City of Tukwila BUILDING DIVISION SUBMITTAL Standard CORREC ION LTR# Location: indoor Installation: above/below grade Flow Rates / Grease Capacities: 35 GPM (2.2 L/s) /130.5 lbs. (59.2 kg) 50 GPM (3.2 L/s) /127.6 lbs. (57,9 kg) Liquid Capacity: 20 gal. (75.7 L) Approval Signature: Weight: 49 lbs. (22.2 kg) Connections: 4 (100 mm) FPT inlet/outlet with 4" x 3" (100 mm x 75 mm) FPT finings Cover: bolted gas/water tight polypropylene with 450 Ib. load rating, or1,000 Ib. when unit is buried with FCR1 riser G19- Date: 0 7 Company: RECEIVED CITY OF TUKWILA JUL 06 2018 PERMIT CENTER Options FCR1 (x1): > 2-1/8° - 12" field cut riser FCR1 (x2): > 12' - 25' field cut risers CC1: membrane clamping collar kit (requires FCR1 riser) PP1: pumpout port kit F32: 3' x 2" (75 mm x 50 mm) FPT finings (x2) Specifying Engineer: Engineering Firm: SCHIER LIFETIME GUARANTEED GREASE INTERCEPTORS MODEL NUMBER: GB2 PART a: 4065-001-01 9500 Woodend Road Edwardsville, KS 66111 Tel 913-951-3300 DESCRIPTION: 35/50 GPM Polyethylene Grease Interceptor DWG BY: B. Karrer www schierproducts com DATE 4/18/2017 ECO: Copyright 2017 Schier All Rights Reserved page 1 of 3 SPECIAL PRECAUTIONS For Ail Schier Great Basin Grease Interceptor Installations Installation Instructions Installation instructions and additional components are located inside the interceptor. Read all instructions prior to installation. This interceptor is intended to be installed by a licensed plumber in conformance with all local codes. When Installing Interceptor Inside If your dishwashing sink(s) discharges into a floor drain/sink (drain), you must regulate the flow into the drain to avoid an overflow of water onto the kitchen floor. This can be done by installing a valve or flow restriction cap on the sink piping that discharges into the drain. See drawing below for guidance. For detailed guidance on indirect connections, go to: http//webtools.schierpr oducts.con/Technical_Data/Indirect_Connections.pdf Fernco or similar rubber flow restriction end cap Hydrostatic Slabs (or Pressure Slabs) When installed under a hydrostatic slab (slab designed to withstand upward lift, usually caused by hydrostatic pressure) interceptor must be enclosed in a watertight concrete vault. Failure to follow this guidance voids your warranty. concrete slab subject to hydrostatic pressure watertight concrete vault High Temperature Kitchen Water If water is entering the interceptor at excessive temperature (over 140° F), a drain water tempering valve (DTV) must be installed. Most state and local plumbing codes prohibit water above 140° F being discharged into the sanitary sewer. Water above 140° F will weaken or deform PVC Schedule 40 pipe, poly drainage fixtures like interceptors and erode the coating of cast iron (leading to eventual failure). Failure to follow this guidance voids your warranty. fhigh temperature T effluent ( > 140° F) Cold water supply line drain water T' tempering valve (DTV) 417-1 it -1I' - Interceptor I High Water Table Installations Interceptors and risers are not designed to withstand water table height in excess of the top of the unit when buried (see figure). If it is possible for this to occur, install the interceptor and risers in a water -tight concrete vault or backfill with concrete or flowable fill (wet concrete and flowable backfill should be poured in stages to avoid crushing the interceptor). At risk areas include but are not limited to tidal surge areas, floodplains and areas that receive storm water. Failure to follow this guidance voids your warranty. Models GB -50, GB -75, and GB -250 that are direct buried in high water table scenarios must be installed with model AK1 anchor kit or warranty is void. max water table height for direct burial SCHIER LIFETIME GUARANTEED ,i. GREASE INTERCEPTORS MODEL NUMBER: GB2 PART u: 4065-001-01 DESCRIPTION: 35/50 GPM Polyethylene Grease Interceptor DWG BY: B. Karrer 9500 woodend Road Edwardsville, KS 66111 Tel 913-951-3300 www.schierproducts.com DATE: 4/18/2017 REV: ECO: -> Copyright 2017 Schier, All Rights Reserved page 2 of 3 SPECIFICATION Notes 1. 4FPT inlet/outlet with 4'x3" FPT fittings. 2. Unit weight - 49 lbs. (wet weight 216 lbs.) 3. Capacities - Liquid: 20 gal. @35 GPM- Grease:130 lbs. (17.8 gal.) @50 GPM- Grease: 127 lbs. (17.3 gal.) 4. Built-in flow control. 5. For gravity drainage applications only. 6. Do not use for pressure applications. 7. Cover placement allows full access to tank for proper maintenance. 8. Vent not required unless per local code. 9. Engineered inlet and outlet diffusers are removable to inspect/clean piping. 10.Integral air relief / anti -siphon. Engineer Specification Guide Schier Great Basinim grease interceptor model #GB2 shall be lifetime guaranteed and made in USA of seamless, rotationally -molded polyethylene. Interceptor shall be furnished for above or below grade installation. Interceptor shall be certified to ASME A112.14.3 (type C) and CSA 9481.1, with field cut riser system, built-in flow control, built-in test caps and three outlet options. Interceptor flow rate shall be 35 or 50 GPM. Interceptor grease capacity shall be 130 lbs. @ 35 GPM or 127 lbs. @ 50 GPM. Cover shall provide water/gas-tight seal arid have minimum 450 lbs. load capacity. Certified Perforniguice Great BCSinTM hydromechanical grease interceptors are third party performance -tested and listed by IAPMO to ASME #A112.14.3 and CSA B481.1 grease interceptor standards and greatly exceed requirements for grease separation and storage. They are compliant to the Uniform Plumbing Code, the National Standard Plumbing Code, the National Plumbing Code of Canada, and the International Plumbing Code, 35' Outlet 'X (Optional) A 23' Inlet Outlet "C" (Optional) 12 7/16' ---i, Shown with optional pumpout port kit Outlet 'B' (Standard) Outlet foot must face this direction in all configurations TOP VIEW 1 Q of plain end inlet and outlet 7 0 211/2' Cover —See Note #10 /I Engineered inlet and outlet diffuser J 6-3/4' invert 1 Static water line *7-1/4' invert when using 4'x3' fittings SECTION A -A SCHIER LIFETIME GUARANTEED GREASE INTERCEPTORS MODEL NUMBER: GB2 PART a: 4065-001-01 DESCRIPTION: 35/50 GPM Polyethylene Grease Interceptor DWG BY: B. Karrer 9500 Wooden(' Road Edwardsville, KS 66111 Tel 913-951-3300 www.schierproducts.com DATE: 4/18/2017 ECO: ' Copyright 2017 Schier, All Rights Reserved page 3 of 3 l-3/4' t...7. 83/4' i III ci " 0,11 I Mt 41PAIMIC"" gpormommisma, Engineered inlet and outlet diffuser J 6-3/4' invert 1 Static water line *7-1/4' invert when using 4'x3' fittings SECTION A -A SCHIER LIFETIME GUARANTEED GREASE INTERCEPTORS MODEL NUMBER: GB2 PART a: 4065-001-01 DESCRIPTION: 35/50 GPM Polyethylene Grease Interceptor DWG BY: B. Karrer 9500 Wooden(' Road Edwardsville, KS 66111 Tel 913-951-3300 www.schierproducts.com DATE: 4/18/2017 ECO: ' Copyright 2017 Schier, All Rights Reserved page 3 of 3 EXPANSION TANY. /. EXISTING TO REMAIN - NO WORK /IN HATCHED AREA UNLESS OTHERWISE NOTED 3/4- RELIEF LINE TO FILL SI2E DRAT TO MOP SINK SEISMIC RESTAINTS. PER UAL NEW HI -LO ACCESSIBLE DRINKING FOUNTAIN INFILL FORMER DOOR OPENING WITH GWB ON METAL STUDS; ALIGN WITH ADJACENT. R -ID RIOGID FOAM INSULATING PAD NEW 3 -COMPARTMENT SINK HAND WASHING SINK TIE INTO EXISTING CW SYSTEM <c� WATER HEATER DETAIL sone: A T NOTE: THIS ROOM WILL ALSO BE USED AS THE SCHOOL HEALTH ROOM/ NURSES OFFICE AS NEEDED. MOP SINK INF LL FORMER DOOR OPENING WITH GWB ON METAL STUDS; ALIGN WITH ADJACENT. REVISIONS No changes shall he made to the scope • of work without prior approval of Tti!ovila Building Division. MOTE: Ravisions will require a new plan submittai and may include additional plan review fees. TIE INTO EXISTING VENT SYSTEM TIE INTO EXISTING HW & CW SYSTEM TIE INTO EXISTING VENT SYSTEM NEW DRINKING FOUNTAIN MODIFIED EXISTING DRINKING FOUNTAIN ROUGH IN P .n Apr th 3 vi ON FLOOR GREASE INTERCEPTOR MODEL SCH ER GB -2 2" INLET & OUTLET General Notes *GREASE (SIZED 18"x24x14 18144 / 78.55 TWO -MINUTE 29.50 Parma aview approval )val of construction )laticn of any roved Field By: .. Date: BUILDING PER 231 x .75 GPM No. adopted Co.y 7 TRAP SIZING CALCULATION UPC 2015 TABLE = 6048 x 3 = 18144 = 78.55 = 58.91 LOAD GALLONS DRAINAGE PERIOD 1014.2.1) = omissions. authorize Receipt SEPARATE PERMIT REQUIRED FOR: C1 Mechanical L'ectricat 1 PSI' mbing l.as Piping City of Tukwila BLOWING DIVISION FILE COPY %18-0077 is subject to errors and documents does not code or ordinance. : d conditions is acknowledged: City of Tukwila DIVISION 1 CORRECTION LETTER #2 7/6/18 No. Revision/Issue Date 3 COMP SINK SCHIER GB -2 GREASE TRAP @ 3 COMP SINK REVIEWED FOR CODE COMPLIANCE APPROVED TIE INTO EXISTING SANITARY SYSTEM JUL 102018 Firm Name and Address STATE MECHANICAL 8706 S 222ND ST KENT, WA 98031 City of Tukwila BUILDING DIVISION N 0 N 117 TIE INTO EXISTING SANITARY SYSTEM CORE ION LTR# Project Name and Address IMPACT CHARTER SCHOOL 3438 SOUTH 148TH ST TUKWILA, WA 98168 WAND SINK HAND SINK RECEIVED CITY OF TUKWILA JUL 06 2018 PERMIT CENTER *ALL WTR CLOSET TO BE 3" WASTE *ALL DRAINS TO SINKS. TO BE 2" WASTE WITH I-1/211 TRAP ARMS *CLEAN OUTS PER CODE Project IMPACT CHARTER SCHOOL Sheet P . 0 Date JUNE II, 2018 Scale NONE July 05, 2018 City of Tukwila Department of Community Development STEVE CARNEY 8706 S 222ND ST KENT, WA 98031 RE: Correction Letter # 2 PLUMBING/GAS PIPING Permit Application Number PG18-0077 IMPACT CHARTER SCHOOL - 3438 S 148TH ST Dear STEVE CARNEY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: LEE SIPE at 206-431-3656 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Provide a new plan set where all sheets are STAMPED WITH SIGNATURE BY THE DESIGN PROFESSIONAL, REQUIRED. See general notes above. 2. Provide SPECIFICATIONS AND ELEVATION DETAIL to show the grease interceptor shall be located above the floor and at a location where it shall be easily serviced. Provide manufacturers installation specifications. Show the GI is sized for the application, WITH CALCULATION OF SIZING OF GREASE INTERCEPTOR. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. P618-0077 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 June 20, 2018 City of Tukwila Department of Community Development STEVE CARNEY 8706 S 222ND ST KENT, WA 98031 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 18-0077 IMPACT CHARTER SCHOOL - 3438 S 148TH ST Dear STEVE CARNEY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Provide a new plan set where all sheets are stamped with the signature of the design professional. See general notes above. 2. Provide specifications or elevation details to show the grease interceptor shall be located above or below the floor and at a location where it shall be easily serviced. Provide manufactures installation specifications. Show the GI is sized for the application. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accented through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. PGI8-0077 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 °PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0077 DATE: 07/06/18 PROJECT NAME: IMPACT CHARTER SCHOOL SITE ADDRESS: 3438 S 148 ST Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 2 Revision # after Permit Issued DEPARTMENTS: AT C 1'0'1 Building Division III Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 07/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) DUE DATE: 08/07/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0077 DATE: 06/28/18 PROJECT NAME: IMPACT CHARTER SCHOOL SITE ADDRESS: 3438 S 148TH ST Original Plan Submittal X Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: co rt. -1-s -NI Building Division pp Public Works E Fire Prevention Structural E Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable E (no approval/review required) DATE: 07/03/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved fl Approved with Conditions Corrections Required (corrections entered in Reviews Denied (ie: Zoning Issues) DUE DATE: 07/31/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1—E. -A Departments issued corrections: Bldg$ Fire 0 Ping 0 PW 0 Staff Initials: 12118r2013 CPERMIT COORD COPY C) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0077 DATE: 06/13/18 PROJECT NAME: IMPACT CHARTER SCHOOL SITE ADDRESS: 3438 S 148TH ST X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: A- CovJ Building Division II btf\ MiA Public Works Fire Prevention Structural Planning Division LIPermit Coordinator LI PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 06/14/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Ell Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/12/18 LI n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping D PW Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7/6/18 Plan Check/Permit Number: PG18-0077 El] Response to Incomplete Letter # Response to Correction Letter # 2 LJ Revision # after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner 0 Deferred Submittal # RECEIVED CITY OF TUKWILA JUL 0 6 2018 PERMIT CENTER Project Name: Impact Charter School Project Address: 3438 S 148th St Contact Person: Steve Carney Phone Number: 206-575-7527 Summary of Revlsion: 1) Per conversations with Allen & Lee stamp in N/A. The P1.0 sheetprovided was done in house by Steve Camey W/ State Mechanical. 2) Please see attached new spec sheet and revised P1.0 sheet. And the grease trap will be installed above ground & below 3 comp sink. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 6t) Entered in TRAKiT on 07/64 ft. WAPemiit CenteetTemplatefforms \Revision Submittal Formdoc Revised: August 2015 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6/28/18 Plan Check/Permit Number: PG18-0077 ❑ Response to Incomplete Letter # NX Response to Correction Letter # 1 O Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Impact Charter School Project Address: 3438 S 148th St Contact Person: Steve Carney Phone Number: 206-575-7527 Summary of Revision: 1) The P1 n sheet provided was done in house by Steve Carney W/ State Mechanical I am not architect and do not have a stamp. 2) Please see attached spec sheet. And the grease trap will be installed above ground & below 3 comp sink CITY OF TUKWILA PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision includin ate o rev' nnn %, , Received at the Ci of Tukwila Permit Center by: W li� City !. r114 ntEntered in TRAKiT on l,L I I D W:\Permit Center\TemplatesWorms \Revision Submittal Form.doc Revised: August 2015 STATE MECHANICAL COMPA Home Espanol Contact Search L&I A -Z Index Help My L&1 Page 1 of 3 StActeli Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries STATE MECHANICAL COMPANY Owner or tradesperson Principals PLATZ, GERRICK D, PRESIDENT LYNCH, JOHN MICHAEL, VICE PRESIDENT DEWITT, RALPH E (End: 12/18/2012) Doing business as STATE MECHANICAL COMPANY WA U91 No. 600 611 697 8706 S 222nd St KENT, WA 98031 206-575.7527 KING County Business type Corporation Governing persons JOHN LYNCH GERRIK PLATZ; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties PLUMBING License no. STATEMC141C7 Effective — expiration 02/27/1986— 09/01/2019 Bond TRAVELERS CAS & SURETY CO Bond account no. 200686359 $6,000.00 Received by L&I Effective date 08/14/2001 07/27/2001 Expiration date Until Canceled Insurance Continental Western Ins Co $1,000,000.00 Policy no. CPA6028803 Received by L&1 Effective date 08/25/2017 08/23/2017 Expiration date 08/23/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600611697&LIC=STATEMC 141 C7&SAW= 7/11/2018