Loading...
HomeMy WebLinkAboutPermit PG18-0084 - SHAG - TENANT IMPROVEMENT: INSTALL PLUMBING FOR SHAG OFFICE TISHAG 14400 TUKWILA INTERNATIONAL BLVD PGI 8-0084 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov PLUMBING/GAS PIPING PERMIT 0040000180 Permit Number: PG18-0084 14400 TUKWILA INTERNATIONAL Issue Date: 6/20/2018 BLVD Permit Expires On: 12/17/2018 SHAG Owner: Name: Address: Contact Person: Name: TUKWILA CITY OF 6200 SOUTHCENTER BLVD, TUKWILA, WA, 98188 DAVE VAN DUINE Address: 1624 135 PL NE , BELLEVUE, WA, 98005 Contractor: Name: TRI-STATE PLUMBING INC Address: 1624 135TH PL NE , BELLEVUE, WA, 98005 License No: TRISTI*245NZ Lender: Name: Address: 111 Phone: (425) 643-3830 Phone: (425) 643-3830 Expiration Date: 10/1/2018 DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL PLUMBING FOR SHAG OFFICE TI FINAL INSPECTION ONLY - ROUGH -INS INSPECTED UNDER CORE BUILDING PLUMBING PERMIT PG16-0080 Valuation of Work: $7,190.00 Water District: 125 Sewer District: VALLEY VIEW Fees Collected: $179.69 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: LU -)01 �j I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signatur Print N 'AGS C j l4C(( —J a I - Date: 6 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK Q o 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKWIL Community Development partment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: / "1 </ O 0 7J iC ' i LA Z r L + 'L l> Suite Number: Floor: Tenant Name: S /-t' A & PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON —person recei communication Name: D kuc U 4-v Dui Ne_ Address: 6s -os sos 2 33 r`" E_ City: State: Zip- 614— Phone: Li - 6'13- 33o Fax: Email: New Tenant: 54, Yes ❑.. No PL MBIN G NTRACTOR 1 ON , Company Name: I al- S"; L4ic PLQ04r3t,)67 / Address: S- 33 112 P L S"I` City: State: W0o✓�,-v.l�Lc Zip: rc�I� 9'9072- '90'7LPhone: Phone:Fax: '-f LS-- Or 3-- 3 x 3 0 1 2_1-- Contr Reg No.:T2 � sT / �`/ a Exp Date: Tukwila Business License No.: Valuation of Project (contractor's bid price): $ l L 0 Scope of Work (please provide detailed information): /' J S -7vi` r° L.� -i f3, �(- J =� 2 S J f I G rec Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: H:Wpplications\Forms-Applications On Line'2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/or, piping outlets being installed and the quantityow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain I Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature Print Name fa— pc) 1,4c itc-7")(3vS/ - Mailing Address: 6SoS,2 33 (L2 p ` S r` H:WpplicationsWorms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: G Zv--(8 Day Telephone: 6/2-C- 6 `i lrt�OOiO /-v`; c L City State Zip Page 2 of 2 r ILA jO Cash Register Receipt City of Tukwila DESCRIPTIONS PermItTRAK I ACCOUNT QUANTITY PAID $179.69 PG18-0084. Address: 14400 TUKWILA INTERNATIONAL BLVD Apn: 0040000180 $179.69 Credit Card Fee $5.23 Credit Card Fee R000.369.908.00.00 0.00 $5.23 PLUMBING $166.15 PERMIT FEE R000.322.100.00.00 0.00 $133.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.31 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14757 R000.322.900.04.00 0.00 $8.31 $179.69 Date Paid: Wednesday, June 20, 2018 Paid By: WILLIAM QUACKENBUSH Pay Method: CREDIT CARD 05535G Printed: Wednesday, June 20, 2018 2:03 PM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 06/20/2018 02:01:16 PM CREDIT CARD SALE VISA CARD NUMBER: **********0500 K TRAN AMOUNT: $179.69 APPROVAL CD: 05535G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy Page 2 of 2 https://classic.convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTra... 6/20/2018 INSPECTION RECORD t) Retain a copy with permit 141-6):S INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec • i i' /, Type of Inspe tion: Lk r fJ A-t— Address: Pig° 0 i t Ie. -I' Date Called: k Special Instructions: Date Wanted: a.m. p.m. - Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 7T32(.9A/ c Ins pector:;Z5d(j...— Date 2/— ZZ,ter/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. TRI-STATE PLUMBING INC Hoene Espanol Contact Safety & Health Claims & Insurance CoWashington State Department of Labor & Industries Page 1 of 5 A-Z1ndex help b1vL&I Workplace Rights Trades & Licensing TRI-STATE PLUMBING INC Owner or tradesperson Principals QUACKENBUSH, WILLIAM J, PRESIDENT MICHAEL, GARY V, VICE PRESIDENT GOODMAN, WILLIAM E, VICE PRESIDENT DARNELL, FRED N, VICE PRESIDENT (End: 09/03/2002) ARNONE, CHARLES J, VICE PRESIDENT (End: 09/03/2002) CANON, PAUL E, VICE PRESIDENT (End: 09/13/2010) MICHAEL, GARY V, VICE PRESIDENT (End: 09/13/2010) Doing business as TRI-STATE PLUMBING INC WA UBI No. 600 151 772 6505 233RD PL SE WOODINVILLE, WA 98072 425-643-3830 KING County Business type Corporation Governing persons WILLIAM J QUACKENBUSH PAUL E CANON; GARY . MICHEAL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. TRISTI*245NZ Effective — expiration 08/09/1976-10/01/2018 Bond Lexon Ins Co Bond account no. 9816460 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/26/2013 04/20/2013 Expiration date Until Canceled Bond history Insurance Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600151772&LIC=TRISTI*245NZ&SAW= 6/20/2018