Loading...
HomeMy WebLinkAboutPermit PG18-0095 - TAVOUR - KITCHENETTE AND UTILITY SINKTAVOUR 770 ANDOVER PARK E PGI 8-0095 Parcel No: Address: City of Tukwila Deportment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 2623049095 Permit Number: 770 ANDOVER PARK E Project Name: TAVOUR Issue Date: Permit Expires On: PG 18-0095 12/4/2018 6/2/2019 Owner: Name: Address: 790 ANDOVER LLC: PO BOX 287 , MEDINA, WA, 98039 Contact Person: Name: MATTY PLUMMER. Address: 770 ANDOVER PARK E , TUKWILA, WA, 98188 Contractor: Name: PARAMOUNT CONST GROUP LLC Address: 11700 MUKILTEO SPEEDWAY STE 201 #1234, MUKILTEO, WA, 98275 License No: PARAMCG869LK Lender: Name: Address: Phone: (757) 613-6194 Phone: (206) 799-6467 Expiration Date: DESCRIPTION OF WORK: INSTALL KITCHENETTE AND UTILITY SINK. CUT CONCRETE TO CONNECT TO EXISTING WATER AND SEWER PIPES. Valuation of Work: $5,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $171.40 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature: 2017 2017 2017 2015 Date: Z /g 1 hearby certifthat I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governng this work will be complied with, whether spedfied herein or not. The granting of this permit does not presume to give authority to violator cancel the provisions of any oter state or local laws regulating construction or the performance of work. am authorized to sign and obtain this development permit and agree o e conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the woris not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Buildirig Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: Alt ptumbing and gas piping systems shalt be tested and approved as required by the Ptumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing lnspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing, All hot and cold water pipes instatled outside the conditioned space shall be insutateci to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steet nail plates not Iess than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the buitding code. 11: Piping in the ground shalt be laid on a firm bed for its entire Iength. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boutders, cinderfitt, frozen earth, or construction debris. 12: The issuance of a permit or approvat of ptans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction, 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: Alt new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, "ndustrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWIa Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaVv'A.gov . 1 Plumbing/Gas Permit No. Project No. GIO-oOqs- Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 770 ANDOVER PARK E Suite Number: Floor: Tenant Name: TAVOUR PROPERTY OWNER Name: Matty Plummer Name: LBA RVI -COMPANY XVI, LLC City: Tukwila State: WA Zip: 98188 Address: 600 University Street, Suite 3025 Email: matty@tavour.com City: State: WA Seattle98101 Zip: CONTACT PERSON — person receiving all project communication Name: Matty Plummer Address: 770 Andover Park E City: Tukwila State: WA Zip: 98188 Phone: (757) 613-6194 Fax: Email: matty@tavour.com New Tenant: j Yes PLUMBING CONTRACTOR INFORMATION Company Name: Paramount Construction Group Address: 11700 Mukiteo Speedway #201 City: Mukiteo State: WA Zip: 98275 Phone: (206) 799-6467 Fax: Contr Reg No.: PARAMCG869LK Exp Date: 06/12/2020 Tukwila Business License No.: Valuation of Project (contractor's bid price): 5,000 Scope of Work (please provide detailed information): Install kitchenette and utility sink. Cut concrete to connect installation to existing water and sewer pipes. Building Use (per lnt'I Building Code): Occupancy (per lnt'I Building Code): utility Purveyor: Water Tukwila HAApplications \ Forms -Applications On Line‘20 I I Applications \Plumbing Permit Application Revised 11i9-11.docx Revised August 2011 bh Sewer Tukwila Page I of 2 indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower 1111 Dishwasher, domestic with independent drain Shower, single head trap ■ Sinks 2 Rain water system - per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) IllWater Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet 1111 Food -waste grinder. commercial Drinking fountain or water cooler (per head) ■ Lavatory UrinalII heater and/or vent IllWater Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow 9 rotections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder. commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backtlow prolective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building scwer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT:Ross Signature: Beckley Digitally signed by Ross Beckley Date: 2018.06.19 08109:46 -07'00' Date: 06/19/2018 Print Name: Ross Beckley Day Telephone: (206) 812-1000 Mailing Address: 600 University Street, Suite 3025 Seattle WA 98101 City State Zip H:\Applications\Forrns-Applications On Line201 I Applications\ Plumbing Permit Application Revised Revised: August 2011 bh Page 2 of 2 CashRegister Recei City of Tukwila (-\ DESCRIPTIONS f ACCOUNT QUANTITY PAID PermitTRAK $171.40 PG18-0095 Address: 770 ANDOVER PARK E Apn: 2623049095 $171.40 Credit Card Fee $4.99 Credit Card Fee R000.369.908.00.00 0.00 $4.99 PLUMBING $160.01 PERMIT FEE R000.322.100.00.00 0.00 $94.86 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PLAN CHECK FEE R000.322.103.00.00 0.00 $32.00 TECHNOLOGY FEE $6.40 TECHNOLOGY FEE R000.322.900.04.00 0.00 $6.40 TOTAL FEES PAID BY RECEIPT: R 4960 $171.40 Date Paid: Monday, July 16, 2018 Paid By: MATTHEW PLUMMER Pay Method: CREDIT CARD H72622 Printed: Monday, July 16, 2018 1:56 PM 1 of 1 Y c . SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 07/16/2018 01:54:18 PM CREDIT CARD SALE VISA CARD NUMBER: **********1661 K TRAN AMOUNT: $171.40 APPROVAL CD: H72622 RECORD 4: 000 CLERK ID: Bill Thank you! Customer Copy https : //classic. convergepay. com/V irt:ualMerchant/transaction. do?dispatchMethod=printTra... 7/1 6/20 1 8 INSPECTION NO. INSPECTION RECORD Retain a copy with permit t4; DrAS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit inspection Request Line (206) 438-9350 Project: (. A \kJ 2, J1 P11L Type of Inspection: B. %Arlek(7 rii4.. Date Called: Date Wanted: -Me...444 <le Address: no 4 . Special Instructions: Requester: Phone No: FilApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTIO EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION RECORD _I Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 it) A vf, aqs Projec : 1-41VCIJ9-- Type of Inspection: Ri/enhrJG 4,(. -- Date Called: 6 Address: 110 Davic5i, Special Instructions: CAL-- "V pvte Date Wanted: a.m. 3-13-r Cr • Requester: ,wygie I) Phone No: 4Z5- -ZeZ3' e7 3/ proved per applicable codes. Corrections required prior to approval. COMMENTS: _Of .01 bk. "--TAer 4_ AktdioFiefiaa In c or: Date: n REINSPECTIO EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projct: • v'ou a_ Type of Inspeltionl. V---- • .-A/1413Ple-1 Address: • L ?LAIL f'4t-1; Date Called: Special Instruc ions: Date Wanted: 448 X-- e•Mi p.m. Requester: RI 00 Phone No: A Z 3' Z4,30 ,671?;,1 proved per applicable codes. OCorrections required prior to approval. COMMENTS: NE:_data/Q_G (J04-100 "D-4 kleitier inspector: Date: 4270 REINSPECTION fEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. July 23, 2018 City of Tukwila Department of Community Development MATTY PLUMMER 770 ANDOVER PARK E TUKWILA, WA 98188 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 18-0095 TAVOUR - 770 ANDOVER PARK E Dear MATTY PLUMMER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - PG DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12.081). (BUILDING REVIEW NOTES) 1. Provide plumbing pipe line drawing details for the sink drain/waste and supply lines. Specify type and size of fixture or sink. Identify pipe sizes, venting and all points of connections. Specify slope of drain pipes. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, ac e - • ipley Permit Technician File No. PG18-0095 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 -PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0095 PROJECT NAME: TAVOUR SITE ADDRESS: 770 ANDOVER PARK E Original Plan Submittal X Response to Correction Letter # 1 DATE: 08/22/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: M tbr411 Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 08/23/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 09/20/18 •••••••••••• Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire 0 Ping 1=1 PW 1:=1 Staff initials: 12/18/2013 'PERMIT COORD COPY 'J PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0095 PROJECT NAME: TAVOUR SITE ADDRESS: 770 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 07/16/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: covst2. 3-4H� Building Division ‘WC/ AY 11(6 C6 Public Works Fire Prevention Structural PRELIMINARY REVIEW: Not Applicable (no approval/review required) Planning Division Permit Coordinator DATE: 07/17/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Approved with Conditions DUE DATE: 08/14/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Fire Ping 0 PW Staff Initials: 12/18/2013 r� ti City of Tukwila Departnrenie of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-4:31-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ib Plan Check/Permit Number: P&7 t -06q ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: tUL ' 1 ..L. Project Address: 770 6-41/2'C --?..kr-k_ a Il v KW i G (amu CK,5/8j Contact Person: {,1 1Arn ate/t— Phone Number: '67 (.13 61q L/ Summary of Revision: [(�� ° Ploe lv'€ c1,,t,wt ht tv{' 6Ak G Leg -6_ • sire_ GV1e__, ` oc- k -AAL -tri 346,6-e-6._ ° 1J1pe_ size -s C'AV\c Cfrooec bon ?NAVA ,6.12.-Vtki Vi 6__ RECEIVED CITY OF TUKWILA AUG 2 2 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including hof revisio Received at the City of Tukwila Permit Center by: [h ---`Entered in TRAKiT on W:\Pern¢t Center\Templates\Forms\ Revision Submittal Formdoc Revised, August 2015 PARAMOUNT CON ST GROUP k Washington State Department of I Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance I_S_rearch L&I Page 1 of 2 A -Z hides !lel!) My 1.&I Trades & Licensing Workplace Rights PARAMOUNT CONST GROUP LLC Owner or tradesperson HARDWICK, RYAN D Principals HARDWICK, RYAN D, MANAGER Doing business as PARAMOUNT CONST GROUP LLC WA UBI No 603 399 677 11700 MUKILTEO SPEEDWAY STE 201 #1234 MUKILTEO, WA 98275 206-799-6467 SNOHOMISH County Business type Limited Liability Company Governing persons RYAN HARDWICK License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PARAMCG869LK Effective — expiration 06/12/2014— 06/12/2020 Bond Travelers Cas and Surety Co of America Bond account no. 106109861 Received by L&I 06/12/2014 Insurance MESA UNDERWRITERS SPECIALTY IN Policy no. MP0046003008701 Received by L&I 05/29/2018 Active. Meets current requirements. $12,000 00 Effective date 06/01/2014 Expiration date Until Canceled 52,000,000.00 Effective date 06/01/2018 Expiration date 06/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI-603399677&LIC=PARAMCG869LK&SAW= 12/04/2018 PARAMOUNT CONST GROUP LI,C No L&I tax debts are recorded for this contra may be recorded by other agencies. License Violations No license violations during the previous 6 year period. 'icense during the previous 6 year period, but some c a Workers' comp No active workers' comp accounts during the previous 6 year period. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 (.0 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603399677&LIC=PARAMCG869LK&SAW= 12/04/2018 F E D B A 39'-101/4" 30'-0" u "—Womenni 02 Men 03 — Office 1 01 2,350 sf Dock 11 760 sf Elec Kitchen 07 160 sf / 40' - 0" L 6V-Fi 31 L1nitS el,,evit? psi r✓ f.P Existing sanitary Iines(s be ow conc slab, utilize for new sink(s) drain. f'JcN Cf u kL 51..S coNcFLTE c-VT f-Dg NEW 1 M' fMy 146 NGW CLEANOtj t"3l 17 bt' - Cr= w''ro L 1STl `t / / / / / / / / / / / / / 16jto'�i i General Storage 10 15,735 sf 148 to exit / / / / / / / / / Suite 770 / Permit in 0 121.4cchanical E Eiectr►cai ❑✓Plumbing ud Cas Piping City of Tukwila BtJILIVISION FILE COPY Wt5/ Plan review ap,;rrv..al is subject to errors ar,.l cmic ;ions. Approval of cons'; icton dos, ; onis d :a nci :'Eo,iza the violation of ard+ adopted code or crdin r c3. racsi,pt of approved Field Copy and condi ions is c:::r, ,•.: ,d cct: By: Date: 5 '(O c vc C City-o uk).v3 s BUILDING DIVISIOf O alEVISIONS No C enges Arli hr-) made to the scope ot!work witha;.;t pror approval of Tu!zwila Bt ;',_;iric Division a Fevisiens will rr quiro a nsw plan submittal fi 'i rcny 1n : i.lde addtrinal planfees nre�n:y^' �r 40'-0" 40'-0" 40'-0" Floor Plan Suite 770 1/8" = 1'-0" Scope of work: 1. Install new Kitchen Room with 2x4 wood stud with 5/8" GWB ea side partition, provide new 2x4 lay in ceiling suspended from new 2x6 rafters at 24" oc spanning the short dimension. 2. Install new kitchen counter with sink, link to existing sanitary line below slab. 3. Install new Utility sink, link to existing sanitary line below slab. Occupant Load Code Calulation Description Net Area Unit Occupancy Type Occupant/ SF Total Occ. Code Section Tenant Suite - Office 1 2,350 SF B 100 24 Tbl 1004.1.2 Kitchen 160 SF B 100 2 Tbl 1004.1.2 General Store e 15,735 SF F2 200 79 Tbl 1004.1.2 Toilet, Elec rms NA Total 18,245 104 30'-0" REVIEWED FOR CODE COMPLIANCE APPROVED a) 0.) o -F-+ F,$) W vaeE"' La;) co 0 Fa= O O c Fam AUG 2 8 2018 12- City of Tukwila BUILDING DIVISION. a) tY 8 0 CORRE TION LTR# ti N Shoreline, WA 98133 tri 0 TIC CO 0 0 N 0 Z 0 N 0 0 0 w a z 0 w v 0 a cc 0 0 w it a it cc n`. ci SHEET TITLE Floor Plan, Key Plan, Occupant Load Table RECEIVED CITY OF TUKWILA AUG 22 2018 PERMIT CENTER SCALE: As indicated DRAWN BY: DATE: 06/12/18 CHECKED BY: PROJ. No: 12589-00 SHEET No: !--1" Building Key Plan 1/64" = 1'-0"