Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit PG18-0132 - SOUTH CENTER SOUTH - CONNECT NEW GAS PACK UNIT TO EXSITING GAS LINE
SOUTHCENTER SOUTH 18360 OLYMPIC AVE S PGI 8-0132 Parcel No: Address: Project Name: City of Tukwila l A Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 7888900155 Permit Number: PG18-0132 18360 OLYMPIC AVE S SOUTH CENTER SOUTH Issue Date: 11/9/2018 Permit Expires On: 5/8/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RREEF CPIF OLYMPIA PROP LLC PO BOX 4900 DEPT 207 C/O RYAN, SCOTTSDALE, WA, 85261 DAVID DENISIUK 1916 220TH ST SE SUITE M101, BOTHELL, WA, 98021 PACIFIC AIR CONTROL INC 1916 220TH ST SE, STE 101 , BOTHELL, WA, 98021 PACI FAC230P8 /I! Phone: (206) 396-0182 Phone: (206) 682-6393 Expiration Date: 10/1/2019 DESCRIPTION OF WORK: CONNECT NEW GAS PACK UNIT TO EXSITING GAS LINE. Valuation of Work: $1,000.00 Water District: TUKWILA Sewer District: TUKWILA Fees Collected: $129.28 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 0 -9 -IR I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions • ached to this permit. Signature:' Date: Print Name: (i/7--)C✓1/S/ LGh This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 9002 ROUGH -IN GAS PIPING CITY OF TUKW A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Plumbing/Gas Permit No. Project No. �y Date Application Accepted: 10 1'K,'DV7'I- ;fjJ Date Application Expires: f 19 1(1 (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 18360 Olympic Ave S Tenant Name: South Center South King Co Assessor's Tax No.: Suite Number: Floor: 1 New Tenant: 0 Yes .. No PROPERTY OWNER Name: RREEF CPIF Olympia PROP LLC Address: 20415 72nd Ave S City: Kent State: WA Zip: 98032 CONTACT PERSON — person receiving all project communication Name: David Denisiuk Address: 1916 220th St SE Suite M101 City: Bothell State: WA Zip: 98021 Phone: (206) 396-0182 Fax: Email: davidd@pacificaircontrol.com PLUMBING CONTRACTOR INFORMATION Company Name: Pacific Air Control Address: 1916 220th St SE Suite M101 City: Bothell State: WA Zip: 98021 Phone: (206) 682-6393 Fax: (206) 340-2270 Contr Reg No.: PACIFAC230P8 Exp Date: 10/01/2019 Tukwila Business License No.: BUS -0995096 Valuation of Project (contractor's bid price): $ 1,000 Scope of Work (please provide detailed information): Connect new gas pack unit to existing gas line. Building Use (per Int'l Building Code) - Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer H:\Applications\Forms-Applications On Line\201 I Applications\Plumbing Permit Application Revised 8-9-11 .docx Revised: August 2011 bh Page 1 of 2 Indicate type of plumbing fixtures and/c. -gas piping outlets being installed and the quanth,-oelow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS R AUTHORIZED AG NT: Signature: Print Name: aVI" ' / l5/P-4 Mailing Address: /,/4 2ZO t4 S f 5 Z^ Day Telephone: c. "ON .001-e// W4 TT v z 1 City State Zip Date: 9/ .Og (Za,)36- C/ gz H:1ApplicationsWorms-Applications On Line12011 Applications\Plumbing Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Page 2 of 2 RegisthrReceipt City of Tukwila eceipt Nuniber R15743 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $129.28 PG18-0132 Address: 18360 OLYMPIC AVE 5 Apn: 7888900155 $129.28 GAS $124.31 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 R000.322.100.00.00 0.00 $66.30 PLAN CHECK FEE R000.322.103.00.00 0.00 $24.86 TECHNOLOGY FEE $4.97 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R15743 $4.97 $ 29.28 Date Paid: Wednesday, October 31, 2018 Paid By: PACIFIC AIR CONTROL Pay Method: CHECK 029832 Printed: Wednesday, October 31, 2018 12:45 PM 1 of 1 YSTEMS INSPECTION RECORD Retain a copy with permit .11S INSPECTION — INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: eavest— -40701 Type of Inspection: 1-4--st seq°,4. iq,,,,,t_ Address: VE3360 0.11,4401(_ Atii S Date Called: • Special Instructions: Date Wanted: 4417 ic? 0":1177, p.m. Requester: Phone No: proved per applicable codes. OCorrections required prior to approval. MMENTS: ..oi;g. Inspector: Date: 1-11 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. O INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pb /g- DI3t. Project: DI/Ifi Lahti Sa>rr Type of Inspection: "moi /4/ 445 pot1/2v4 Address: /$3i, oLyMIk— Agog S. Date Called: Special Instructions: Date Wanted: i/. /S-ZdB a.m. p.m. Requester: Phone No: Approved per applicable codes. L, Corrections required prior to approval. OMMENTS: Date: REIN"•ECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: V 14*". C,r)11:er- ci44(e...1 Type,f Inspection: g p 1 r‘b Address* 0 1 /it -5: Date Called: p Special Instructions: it DateWanted: _?..- C2Lr507, Requester: Phone No: LJApproved per applicable codes, Corrections required prior to approval. COMMENTS: Alc,J I-, Ali eadS 14?•Lri-tte.... r 610 rdp,-; 1- if .2S -oris Inspector: Date: j icor REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Can to schedule reinspection. 4/1/2019 / City of Tukwila Department of Community Development DAVID DENISIUK 1916 220TH ST SE SUITE M101 BOTHELL, WA 98021 RE: Permit No. PG18-0132 SOUTH CENTER SOUTH 18360 OLYMPIC AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/14/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/14/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. ,L2GC f- Q C Kandace Nichols Permit Technician File No: PGI8-0132 6300 Southcenter Boulevard Suite 4100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 f 1 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0132 DATE: 10/31/18 PROJECT NAME: SOUTH CENTER SOUTH SITE ADDRESS: 18360 OLYMPIC AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: r G t t\ %6 Building Division um �� Nor (I t\r6 Pubic Works Fire Prevention Structural n Planning Division nPermit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/01/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/29/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PACIFIC AIR CONTROL INC ' Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & industries Page 1 of 2 Search L&I AA index Help Workplace Rights Trades & Licensing PACIFIC AIR CONTROL INC Owner or tradesperson Principals RUTTAN, GARY JAMES, PRESIDENT CRAWFORD, LARRY C, SECRETARY (End: 10/05/2011) Doing business as PACIFIC AIR CONTROL INC WA UBI No. 601 298 907 1916 220TH ST SE STE 101 BOTHELL, WA 98021-8427 206-682-6393 SNOHOMISH County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. PACIFAC230P8 Effective — expiration 10/28/1977-10/01/2019 Bond Active. Meets current requirements. TRAVELERS CAS & SURETY $6,000.00 Bond account no. 104920215 Received by L&I Effective date 05/09/2007 05/26/2007 Expiration date Until Canceled Insurance PHOENIX INSURANCE COMPANY THE $1,000,000.00 Policy no. 4TC07314N491PHX09 Received by L&I Effective date 06/19/2018 07/01/2010 Expiration date 07/01/2019 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601298907&LIC=PACIFAC230P8&SAW= 11/9/2018 ° " '6 Air Conditioning LEGAL DESCRIPTION: LEGE\ D & ABBREVIATIONS w.p.maay."r'r°'°a.r .1 ..w ". r Heating Controls Sales Service Installation e;+4y;""Y'-�9&'iwuY'a1dGwn;r¢dkzS r "QUALITYASSURED" � ,WSM,r. pacific air control, 1919 16 220th Street SE Bothell, WA ell, 98011 p 682-6393 Contractor's License www.pacificaircontrol.com inc. Suite M101 fax: (206) 340-2270 No.: PACIFAC230P8 SOUTH INDUSTRIAL PARK LOTS 19 & 20 AMEND TUKWILA SHORT PLAT NO SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION HVAC GENERAL COTES DUCT COTES MF 78-19-SS RECORDING NO 7807210798 SD PLAT DAF - BEG SW COR LOT 16 PLAT OF SOUTHCENTER SOUTH INDUSTRIAL 1. VERIFY SITE CONDITIONS. 1. DUCT CONSTRUCTION AND INSTALLATION PER LATEST SMACNA STANDARDS AND THE 11-23-50 E 698.25 FT TH 2015 SMC AS REQUIRED BY THE LOCAL CODE. PROVIDE METAL DUCT,EXCEPT AS THRU 2. THERMOSTAT LOCATIONS: VERIFY ALL WALL MOUNTED CONTROL LOCATIONS WITH ARCHITECT/GC.C/A 90-00-00 TH S PARK TH N 78-36-10 W 360 FT TH N ® ALG CURVE TO RGT RAD 110 FT ARC DIST 172.79 FT 78-36-10 E 480 FT TH ALG CURVE TO RGT RAD 110 FT �� I/ SUPPLY DUCT ® FIRE DAMPERED DUCT PENETRATION OF A RETURN/EXHAUST DUCT HORIZONTAL SEPARATION NOTED. ARC DIST 172.79 FT THRU C/A 90-00-00 TH S 11-23-50 W 648.25 FT TH ALG SL SOUNDLINED DUCT 3. CODES: COMPLY WITH ALL LOCAL & STATE GOVERNING CODES. V FIRE DAMPERED DUCT PROPOSED PROJECT FOR: S���UTH CENTER Sz��UTH 18360 OLYMPIC AVE S TUKWILA WA 4. COORDINATE DUCTWORK AND GRILLE LOCATIONS WITH LIGHTING AND OTHER RELATED TRADES WITH 2. BALANCING DAMPERS: PROVIDE ON ALL SUPPLY RUN OUT DUCTS UP STREAM OF CURVE TO LFT RAD 50 FT ARC DIST 78.54 FT THRU C/A 90-00-00 TH N 78-36-10 rfl VD MANUAL VOLUME DAMPER PENETRATION OF A ARCHITECT APPROVAL. VERIFY CLEARANCES & CEILING ELEVATIONS BEFORE INSTALLATION. DIFFUSERS. W TO POB3. VERTICAL SEPARATION DUCT INSULATION: DUCTS, SHAFTS AND PLENUMS SHALL BE INSULATED TO MINIMUM 5. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW EXACT ROUTING OR EVERYri FC FLEX CONNECTOR OF R-8 AND IN ACCORDANCE WITH THE SECTION C403.2.8 OF 2015 WSE. OFFSET WHICH MAY BE REQUIRED. 4. DUCT SEALING -GENERAL: 0 TO 2 STATIC PRESSURE - SEAL ALL TRANSVERSE TAX PARCEL NUMBER: 7888900155 TV TURNING VANES o TIMER 0-4 HR ADJUSTABLE 6. SEISMIC BRACING: PROVIDE TO MEET LOCAL CODE REQUIREMENTS. REFER TO THE ASHRAE ~ THERMOSTAT HVAC UNIT EC END CAP O / # STANDARDS "PRACTICAL GUIDE TO SEISMIC RESTRAINT". JOINTS AND LONGITUDINAL SEAMS ON ALL DUCTS. ABOVE 2"-SEAL SEAMS, JOINTS 7. EXHAUST FAN TERMINATION: SHALL NOT BE LESS THAN 3 FEET FROM A PROPERTY LINE OR AND WALL PENETRATIONS. INSIDE BUILD: DURODYNE "DDS-181" GRAY OR E I SD SUPPLY DIFFUSER, CEILING O SENSOR/HVAC UNIT OPENINGS INTO A BUILDING, E.G., OPERABLE WINDOWS AND DOORS, OR DISTANCE AS REQUIRED APPROVED EQUAL PER UL 181 A-M, 181B-M LISTED. OUTSIDE: POLYURETHANE, PER LOCAL CODE. MAMECO VULKEM 116. OR APPROVED EQUAL. SOUTH CENTER SOUTH MG MAKEUP GRILLE @ RG RETURN GRILLE, CEILING SENSOR (CEILING MOUNT) EXHAUST FAN 8. TEST, ADJUST, & BALANCE: PROVIDE PROPER SYSTEM TESTING, ADJUSTING, AND BALANCING, 5. TURN VANES: PROVIDE SINGLE THICKNESS TURN VANES (SEE DETAIL) IN ALL MAJOR INCLUDING WRITTEN REPORTS TO BE PROVIDED TO OWNER. BALANCE TO WITHIN 10% OF DESIGN. SQUARE DUCT ELBOWS, TEES, OR TURNS WITH INSIDE RADIUS LESS THAN 3/4 � � Np °x �� ��� � m � /1 / I• EG EXHAUST GRILLE, CEILING PIPE/DUCT UP 9. OPERATION & MAINTENANCE BOOKLET: PROVIDE 0 & M MANUAL TO OWNER. INCLUDE CUT SHEETS DUCT WIDTH. SQUARE BRANCH DUCT TAPS SHALL BE 45 DEGREE TYPE PER INSTRUCTIONS, AND MARKED UP AS � � b r /� o TRANSFER GRILLE, CEILINGPIPE a DUCT DOWN ON MAIN EQUIPMENT AND CONTROLS, MAINTENANCE -BUILT SMACNA STANDARD. � DRAWING. 6. FLEX DUCT (INSULATED): FOR GRILLE RUN OUTS UP TO 6 FT. LONG, EXCEPT AS 4�� � t , �- mmb ���� gy °+ w , JyTG -I �-- SIDEWALL SUPPLY/MAKEUP v PIPE TEE DOWN 10. COMMISSIONING: PRIOR TO PASSING THE FINAL INSPECTION OR OBTAINING A CERTIFICATE OF NOTED. PROVIDE ADJUSTABLE METAL ELBOWS ON ALL TURNS, UNLESS A SMOOTH OCCUPANCY,PROVIDE THE EVIDENCE OF SYSTEM COMMISSIONING AND COMPLETION IN ACCORDANCEb �'PIPE �v � -I - SIDEWALL RETURN EXHAUST o TEE UP tz FULL RADIUS TURN IS MADE. SECURE CORE WITH APPROVED NYLON OR METAL_ WITH THE PROVISIONS OF SECTION C408 OF THE 2015 WSE�'E® „d „ � 3�� � ., � , , ,�b '' WORM DRIVE CLAMPS. NO DUCT TAPE JOINTS &SCREWS ALLOWED. - 1-27 • EQUIPMENT TAG EXIST DUCTWORK, EQUIP 11. WALK-THRU INSTRUCTION: PROVIDE ON SITE WALK-THRU FOR CUSTOMER TO DEMONSTRATE 7. SOUND LINER: PROVIDE SOUND LINED METAL SUPPLY & RETURN DUCTS AS SHOWN OF SYSTEM AFF ABOVE FINISHED FLOOR NEW DUCTWORK, EQUIP OPERATION AND ANSWER QUESTIONS. ON PLANS. MANVILLE PERMACOTE LINACOUSTIC FLEXIBLE FIBERGLASS LINER, WITH . 12. ROOF TOP UNITS ON CURB: SEAL HOLES AND CRACKS BETWEEN DUCT AND ROOF DECK INSIDE ACRYLIC SURFACE TREATMENT OR EQUAL. FABRICATE AND INSTALL PER DUCT LINER FACTORY ROOF CURB FOR NOISE CONTROL. STANDARD OF NORTH AMERICAN INSULATION MANUFACTURER'S ASSOC. 13. GAS PIPE: SCHEDULE 40, BLACK STEEL. PAINT PIPE EXPOSED TO WEATHER. OUTSIDE AIR DUCT IS NOT INSULATED THROUGH UNCONDITIONED AREA.�� 14. SIZES: ALL PIPE SIZES SHOWN ARE MINIMUM. 8. FLEX CONNECTORS: PROVIDE ON ALL DUCT HOOK-UPS TO ISOLATE AIR HANDLINGra MICHIGAN NO.100 OR CLEVIS STYLE NO.400 OR EQUAL 15. PIPE HANGERS: SWIVEL LOOP STYLE, . , � BRAND, WITH ALTHERED STEEL ROD SIZED PER INDUSTRY STANDARDS. EQUIPMENT. (NEOPRENE COATED FIBERGLASS FABRIC TYPE) 16. ELECTRICAL: ALL EQUIPMENT TO HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN g DUCT SIZE CHANGES: ROUND GALVANIZED DUCTS MAY BE SUBSTITUTED FOR SIGHT FROM EQUIPMENT SERVED. PROVIDE A 120 VOLT RECEPTACLE LOCATED WITHIN 25 FEET OF RECTANGULAR DUCTS THAT ARE NOT LINED. PROVIDE CIRCULAR EQUIVALENT OF PURPOSES SMC SECTION 301.10). LINE VOLTAGE RECTANGULAR DUCT. OTHER EQUIVALENT RECTANGULAR DUCT SIZES MAY BE �Wn .. ��:,�,,. VICINI-Y :�.,W�- q , NAP �°� �.k.°,y,} � , a w ��, BD, BDD BACKDRAFT DAMPER " BS BIRDSCREEN DN DOWN __ EA EXHAUST AIR OA, OSA OUTSIDE AIR RA RETURN AIR > CEILING RADIATION DAMPER ADJ ADJACENT BSC BIOLOGICAL SAFETY CABINET CFH CHEMICAL FUME HOOD CFM CUBIC FEET PER MINUTE DB DUCT BOARD EQUIPMENT FOR SERVICE & MAINTENANCE (2015 . SUBSTITUTED TO BEIIER FIT SPACE. WORK BY OTHERS. 10. TEMPORARY DUCT CLOSURE: SEAL OFF DUCTWORK DURING CONSTRUCTION TO 17. SUSPENDED MECHANICAL EQUIPMENT AND APPLIANCES SHALL HAVE RIGID VERTICAL HANGERS AND KEEP OUT CONSTRUCTION DUST, ESPECIALLY FLOOR BOOTS AND LOW WALL BE BRACED IN BOTH HORIZONTAL DIRECTIONS. OPENINGS. NTS SA SUPPLY AIR L,S LIQUID, SUCTION (N) NEW N NECK (E)/EXIST EXISTING NIC NOT IN CONTRACT (R) RELOCATED OAI OUTSIDE AIR INTAKE BWG BOTTOM WALL GRILLE RD ROUND DIFFUSER TWG TOP WALL GRILLE SHC SENSIBLE HEATING CAPACITY ROOFTOP PACKAGED HEAT PUMP UNIT SCHEDULE TYP TYPICAL SR SUPPLY REGISTER VD VOLUME DAMPER TC TOTAL COOLING NOM COOLING [MBH] HEATING [MBH] SUPPLY FAN TOTAL MCA/MOP VOLTAGE WT MIN OSA eI�I 1 DEMO VEL VELOCITY MAKE MODEL SEER [V/PH/HZ] AREA OF WORK TAG TONS TOTAL SENS. INPUT OUTPUT BHP RPM DRIVE TYPE CFM [AMPS] [LBS] CFM CONDITION WH WATER HEATER GP-1 TRANE 4YCC4060A1 1 1 5A 5 58.0 - 115.0 - 14.0 - 1050 DIRECT - 12.90/20 208-230/60/1 482 220 NEW REVISIONS SC SOUND CAN NOTES: POWERED BY OTHERS AIR TERMINAL LEGEND GRILLE, REGISTER, XX 8x8 NECK SIZE (INCHES) DIFFUSER IN LEGEND 140 SQUARE OR RECTANGULAR � - AIR QUANTITY (CFM) XX 8"0 NECK SIZE (INCHES) NO. A DATE DESCRIPTION FOR STRUCTURAL REVIEW - RE65i(7NS 140 ROUND �'- Air Quantity (CFM) ARROWS INDICATE AIR PATTERN FOR CEILING DIFFUSERS NO ARROWS INDICATE FOUR WAY PATTERN A 9 9/11/18 FOR PERMIT A A No changesSh,i'l h , rr;T e to the scope FIRE SPRINKLER HEADS TO BE FAST REACTION TYPE BY OTHERS. A of work wit^: ° -er approval of Tukwila Bi ."(:ding Division a new plan submittal / NOTE: Previsions will require and may include additional plan review tees THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. D ES C I PTI O \ OF WORK: FILE COPY ,46 OI�� SOUTH CENTER SOUTH PROJECT MANAGERDESIGNED AH BY AH/DD Nc6 Permit ®.NTS / 1. DEMO AND REMOVE (3) OLD CONDENSERS, AIR HANDLERS AND REF. LINES DRAWN BY AH CHECKED BY AH Plan review api:, ovcl 13 subject to errors and omissions. ON ROOF Approval documents does SCALE NOTFD PROJECT NO. T180712REVIEVVE of contit; uction not authorizeAS the violation of any adcpted coda or ordinance. Receipt 2. DEMO VENTS ON ROOF Fiold Copy is CODE COMA c1'C nni- ltbisfgetE of approved and conditions acknowledged: APPRUI/VU AILS T By: - D�AWI\G INDEX 3. INSTALL (1) NEW 5 TON UNIT ON ROOF / %74/%//i NOV06'.018DE Date: ' 1\- City of Tukwila M-1 LEGEND & ABBREVIATIONS, VICINITY MAP, EQUIPMENT SCHEDULE, NOTES 4. INSTALL NEW DUCTWORK City of Tukwila BUILDING Di //1310N BUILDING DIVISION SEPA TE FE ,�i lT F QUiF:73 FOR: Elhiccnanical L> Electrical �plumbrng .:':as Piping City of Tukwila MOPING ING DIVISION M-2 DEMO AND SITE PLAN M-3 NEW HVAC AND ROOF PLAN CITY OF TUKWILAI OCT 31 2018 SHEET NUMBER COPYRIGHT M imi .1 of 3 © 2001 PACIFIC AIR CONTROL, INC. PERMIT CENTER ..�. ()% \\SBS\Shared Files\Construction\Autocad Files\Autocad\IProjects\COMCASTABERDEEN Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" NEIGHBORING PROPERTY NEIGHBORING PROPERTY pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 www.pacificaircontrol.com NEIGHBORING PROPERTY r..42firierRAnSIDE DR. NEIGHBORING PROPERLY I NEIGHBORING PROPERLY '1 NEIGHBORING PROPERTY H , y : 4"2- • NEIGHBORING PROPERLY NOGHBORING PROPERTY NEIGHBORING PROPERTY TGDD BLWJ AVE S SKY LI G HT NEIGHBORING PROPERTY 0 51 � w 1111111 NEIGHBORING PROPERLY NEIGHBORING PROPERT M ®0 T %0 SITE PLAN `, N NTS 1 \\ co Ey- Li_ i`ri l - / / 1.11 0 0) �.0 NO CC 0 W 0 a- 0 CL I NO. DATE DESCRIPTION FOR STRUCTURAL REVIEW 00 N A 09/12/18 FOR PERMIT A A =5r,, A 43 -0 ELEVATION DETAIL, SOUTH VIEW i 3/32" = 1'-0" THIS CONTROLWINC. ING ISANYEREPRODUCTION, DUPLICATIOSOLE PROPERIY OF N,C AIR SKYLIGHT ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER DESIGNED BY JT DD DRAWN BY DD CHECKED BY JT 00 SCALE PROJECT NO. 4 _ro AS NOTED T180712 I 6' DRAHING TITLES n DESIGN eirp . �u a ,. , D =p AILEEVIEWED FO R -COMPLIANCE COD DE I APPROVED PAIII DEMO PLAN, CONDENSERS AND AIR HANDLERS Nov os 2ni8 3 16"=1 / ' N EC K EO CITY F Ui�I�JaLt - . f-ThkWi a BUILDING DIVISION NOTES: OCT 31 1. DEMO AND REMOVE OLD CONDENSERS, REFRIGERANT LINES, (o /\ 2018 PERMIT CENTER SHEET NUMBER AND OLD EXHAUST VENTS 24'-8" 1 ELEVATION 3/32" = 1'-0" DETAIL, WEST VIEW of 3 \\SBS\Shared Files\Construction\Autocad Files\Autocad\!Projects\South Center South COPYRIGHT © 2001 PACIFIC AIR CONTROL, INC. GAS LINE NOTES: GAS METER CAPACITY: 500 MBH WAREHOUSE FREEZE PROTECTION MAX: 100 MBH NEW UNIT CAPACITY: 115 MBH TAP INTO GAS LINE PENETRATE ROOF RUN LINE TO UNIT NOTE: GAS LINE ON ROOF TO BE YELLOW GAS LINE: UP TO CEILING T 8"0 120 CFM 1"0 DIFFUSER/GULL SCHEDULE QUANTITY MAKE MODEL SIZE 3 SHOEMAKER 700 MA 8"0 7 SHOEMAKER 700 MA 10"0 6 SHOEMAKER 105 P 8"0 2 SHOEMAKER 105 P 10"0 1 SHOEMAKER 105 P 16" 0 1 SHOEMAKER 105 P 18"0 NOTE: SUPPLY AIR MODEL: 700 MA RETURN/TRANSFER GRILL MODEL: 105 P L 10' 10 "0 180 CFM 10 "0 250 CFM 10 (X2) 8" 0 (X2) 8" 0 8 "0 180 CFM 12 1"0 1-1/2"0 NEW HVAC PLAN 230 CFM 1 6"0 14"0 10" 10 "0 200 CFM X2 10" 12"O 10"0 (N) 1.0" O 230 CFM 10"0 230 CFM 911 I r 10"O 200 CFM GAS METER 1-1/4" CONNECTION R TU ST UCTURAL ROOF LOCATION Air Conditioning Heating Controls Sales Service Installation "QUALITY ASSURED" pacific air control, inc. 1916 220th Street SE Suite M101 Bothell, WA 98011 ph: (206) 682-6393 fax: (206) 340-2270 Contractor's License No.: PACIFAC230P8 www.pacificaircontrol.com PROPOSED Na DATE 08/08/18 DESCRIPTION FOR STRUCTURAL REVIEW 09/11/18 FOR PERMIT THIS DRAWING IS THE SOLE PROPERTY OF PACIFIC AIR CONTROL, INC. ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF PACIFIC AIR CONTROL, INC. PROJECT MANAGER AH DESIGNED BY DD/AH DRAWN BY DD CHECKED BY AH SCALE AS NOTED PROJECT NO. T180712 DRAWING TITLES Dr�1G�, ODE COMPLIANCE SHEET NUMBER \\SBS\Shared Files\Construction\Autocad Files \Autocad\!Projects\South Center Sou COPYRIGHT © 2001 PACIFIC AIR CONTROL, INC.