Loading...
HomeMy WebLinkAboutPermit PG18-0142 - TUKWILA VILLAGE BUILDING A - INSTALL UNDERGROUND GARAGE PLUMBINGTUKWILA VILLAGE BUILDING A 14200 TUKWILA INTL BLVD PGI 8-0142 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov PLUMBING/GAS PIPING PERMIT 1523049242 14200 TUKWILA INTL BLVD Project Name: TUKWILA VILLAGE BUILDING A Permit Number: Issue Date: Permit Expires On: PG 18-0142 2/14/2019 8/13/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA CITY OF 6200 SOUTHCENTER BLVD , TUKWILA, WA, 98188 DAVE VAN DUINE 6505 233 PL SE , WOODINVILLE, WA, 98072 TRI-STATE PLUMBING INC 6505 233 PL SE , WOODINVILLE, WA, 98072 TRISTI*245NZ Phone: (425) 643-3830 Phone: (425) 643-3830 Expiration Date: 10/1/2020 DESCRIPTION OF WORK: INSTALL UNDERGROUND GARAGE PLUMBING INCLUDES INSTALLATION OF A SAND/OIL SEPARATOR AND A 4" REDUCED RESSURE PRINCIPLE ASSY (RPPA). Valuation of Work: $38,000.00 Water District: 125 Sewer District: VALLEY VIEW Fees Collected: $321.01 Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: ",(x.e,e;_ /a-4 Date: -� /V/moi I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: L /j' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing memoers to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 gauge. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 15: Installation of Reduced pressure principle assembly (RPPA) requires a separate inspection from Public Works; call (206) 433-0179 minimum 24 hours in advance to schedule. The applicant or contractor must notify the Public Works Inspector at (206) 433-0179 upon commencement and completion of work at least 24 hours in advance. All inspection requests for utility work must also be made 24 hours in advance. 1 \ 16: The RPPA shall be installed per manufacturer's specifications and tested by a certified tester. 17: Thereafter the RPPA shall be tested annually at the property owner's expense & test report(s) shall be forwarded to Water District #125, 3460 S 148th St, Suite 110, Tukwila, WA 98168, phone (206)242-9747; http://www.waterdistrict125.com 18: Thereafter the RPPA shall be tested annually at the property owner's expense & test report(s) shall be forwarded to Water District #125, 3460 S 148th St, Suite 110, Tukwila, WA 98168, phone (206)242-9747; http://www.waterdistrict125.com PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING 7 \ CITY OF TUKWILA Community Development Deparhnent Perniit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwTukwilaWA.gov /- • Plumbing/Gas Permit No. Project No. Date Application Accepted: 0-1& fi Date Application Expires: 6 (6e, (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 14200 Tukwila International Boulevard Tukwila Village Building A King Co Assessor's Tax No.: 1523049242 Suite Number: PROPERTY OWNER Name: Tukwila Village Development Associates LLC Address: 14400 Tukwila International Blvd Building D City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Dave VanDuine Address: 6505 233rd PI SE City: Woodinville State: WA Zip: 98072 Address: 6505 233rd P1 SE Contr Reg No.: TRISTI*245NZ Exp Date: 10/01/2020 Tukwila Business License No.: BUS -0995599 City: Woodinville State: WA Zip: 98072 Phone: (425) 643-3830 Fax: (425) 747-3041 Email: Floor: New Tenant: 0 Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Tri-State Plumbing Inc. Address: 6505 233rd PI SE City: Woodinville State: WA Zip: 98072 Phone: Fax: (425) 643-3830 (425) 747-3041 Contr Reg No.: TRISTI*245NZ Exp Date: 10/01/2020 Tukwila Business License No.: BUS -0995599 Valuation of Project (contractor's bid price): $ 38,000 Scope of Work (please provide detailed information): Install underground garage plumbing Building Use (per Inel Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: 1-1.:‘ApplicationsTorrnsiiApp Lica, ions On Linc,2011 ApplicationsPlumbing Permit Application Revised 8-9-11.clocx Revised: August 2011 bh Sewer: Page 1 of 2 _J Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain 8 Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) 8 Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or wafer treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial 8 Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 8 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Oficial may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO. BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: UTNORIZED AGENT Print Name: Dave VanDuine Mailing Address: 6505 233rd P1 SE H:`.Applicationsiforms-Applications On Line'2011 Applications Piumbing Permit Application Revis 18-4-11.docx Revised: August 2011 bh Date: 12/06/2018 Day Telephone: (425) 643-3830 Woodinville WA 98072 City State Zip Page 2 of 2 l DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $265.99 PG18-0142 Address: 14200 TUKWILA INTL BLVD Apn: 1523049242 $265.99 Credit Card Fee $7.75 Credit Card Fee R000.369.908.00.00 0.00 $7.75 PLUMBING $245.94 PERMIT FEE R000.322.100.00.00 0.00 $212.79 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $12.30 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16871 R000.322.900.04.00 0.00 $12.30 $265.99 Date Paid: Thursday, February 14, 2019 Paid By: GARY V MICHAEL Pay Method: CREDIT CARD 06067G Printed: Thursday, February 14, 2019 3:41 PM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 S0UTHCENTER BLVD TUKWILA, WA 98188 I86 -433-I878 CITY OF TUKWILA Date: 8I/14/I019 03:40:21 PM CREDIT CARD SALE VISA CARD NUMBER: **********0334 K TRAN AMOUNT: $265.99 APPROVAL CD: 06867G RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $55.02 PG18-0142 Address: 14200 TUKWILA INTL BLVD Apn: 1523049242 $55.02 Credit Card Fee $1.60 Credit Card Fee R000.369.908.00.00 0.00 $1.60 PLUMBING $53.42 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15989 R000.322.103.00.00 0.00 $53.42 $55.O2 Date Paid: Thursday, December 06, 2018 Paid By: DAVID WILLIAM VANDUINE Pay Method: CREDIT CARD 02554D Printed: Thursday, December 06, 2018 3:25 PM 1 of 1 YS TEM 5 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 12/06/2018 03:24:28 PM CREDIT CARD SALE VISA CARD NUMBER: **********9770 K TRAN AMOUNT: $55.02 APPROVAL CD: 02554D RECORD #: 000 CLERK ID: Laurie Thank you! Customer Copy https://classic.convergepay. com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 12/6/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 R4 -?//2 PEaect: -I-WWII-It Vi 1.—LAG4' Type of Inspection: itihMiA/6- -7971-L-- Address: .... / 2e)r.) 77AW/LA kr .46e0 Date Called: Special Instructions: Date Wanted: __,,,, -?3--,(-) a.m. p.m. Requester: Phone No: Approved per applicable codes. Ej Corrections required prior to approval. COMMENTS: 61...1 eect/ov7Zi< Inspector: Date: eP —71) REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: 7UK14A4 ✓jt i— Type of Inspection: PiPIl-(,G Address: hr ie ,x,.h/ Date Called: Special Instructions: f i �Y A r i• y / 4.4 I A Date Wanted: a.m. '20 p.m. g ^11 Requester: �� j C/ s n f�/� Phone No: 7.04) -773-YJ/ • • . - _ _ , Approved per applicable codes. orrections required prior to approval. COMMENTS: /e;-1',.Wo' hr ie ,x,.h/ -J V Ate+' F Q �l^ - / FSG ; vi 4 /12( / a 7,-; -.-i 4e-t-vP - -r,, ,/ /' ---, f. Zefc „.€7,,,,--t / ,/P, ?-21.0� 1 1 n Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 woist-apiz Pro ect: , 4,104.),44 Vfille— Ty e of Ins ection: 1C;Nikt Address: MZOO 7akaii4. 3444-. E bat Date Cal d: Special Instructions: —Date t Wanted: x5izete06 a.m. P.m. Requester: Phone No: DAPP per ap .r .rrections required prior to approval. ""141111p,- "0-4. MEN : inspector: alLera Date: feyzsv/244, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit WA3-611/2_ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro•ec • r J U k(dl1 Gl4 Off T f Ins ction: YP 0�� C // ���Jf��� P4Lt,nU'� A dress: Date Call Special Instructi�o'nss:. ti -100 7-44-w G c 13 I- VC( Date Wanted: l a.m. G� G1� p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: f Z:f-Lte4 Z0.1 6,6i A004, 127-14 Cokti) Isrpoo,G•d g ;--124 r,,, is dA) Al/ f$ pf-e-el Date:ito/zS 7 _j REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 9(? we? Ova_ Project: d it44 V4f, Type of Inspe ion: k-- WA 14W( Address: /"2Q2 "04.4)1e4-8%-,4)10 Date Cale Special Instructions: Date Wanted: <nit p.m. Requester: t7r/A-c-)0 Phone No: Z'53 341 4A,96:3, LJApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Ckl`PrPrr Ae/ 4+PC-20(A2r(-- F ' -3 Inspector: Date: 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ,Ptx. cv*I- ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: 1-&-lA)i LtA \ A ULAO Type of Inspection: G42ctsh4 tioaelt_ Address: 147w --(kA wlgtra-D Date Called: Special Instructions: Date Wanted: ,rY S\ Pall. Requester: 4r..74-44, LA 0' Phone No: 2. sg4-7 1-1-113 LJApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: •e,a0(2,<cast pcppoMAe— ptc-tcl, Lula) e diasa Inspector: 4F-7 Date: 5- 1, EJ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P4 t aiez_ PERMIT NO, CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 81vd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project. j , i(A/1 (44 vti-1,4b( Type of Inspection: . Address: / 24Z74/141/-41 kir ,Vaii‘43 Date Called: Special Instructions: Date Wanted: 4' SI'? P.m. Requester: 6001.00 Phone No: 5-'5 50 07e) L1Approved per applicable codes. Corrections required prior to approval. COMMENTS: .‘ri-acgt. ‘,--rize L`12.94s1-1 • 14,16. Z.ccit-I. -cv. 2, Inspector: "47 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: (e• INSPECTION NO. INSPECTION RECORD Retain a copy with permit 96/ 0142_ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: --ra-eA) I 4A- \A 0-4444 kr Type of Inspection: 4VA/A iii0A1,- Address: _T-,e4,...)i tvvi- / 12Q7 //4153,214910.44-- it -t/ Date Called: Special Instructions: Date Wanted: ri.rn: p.m. Requester: No: Phone No: 533'h 4356 LJApproved per applicable codes. EJCorrections required prior to approval. COMMENTS: ZPa0c/r4-43 _ 1-$ eavat OUST., Inspector; Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 P4 la 014 Project: —r724 U.DIVA- 1/114,446 Type of Inspection: 442(211ni Address: A 12et011_41- Air Date Called: d' -'A Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Z3 3'i1 93,0 EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: 172t241/04-.4t3/11C____ —**liZ'Al f44.24,1A.&_ E.47 Inspector: Date: REINSP TIONyE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit N tON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 f3t3 °via 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 'C) 4)(L461 VI LAWAI Type of Inspection: Zlect.70--6 (A Address: /42x decdit.'/r /P-ri' 6-03 Date Called: Special Instructions: t 1 Date Wanted: . . Requester: 4 e a, PI -Lo . Phone No: 25' 34-k-1 137E3 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 6242,,,A)wactc— otr JI.%...%)e.AK/ 0-45 ese- Act00.42 a of) Inspector: Date: >ea` ICI REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P618 -01L12 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: . it, i % --T—LkY-NO 1 LA- V i 11,9-e_ Type of Inspectiog 6 repv,y‘&wor-t Address: tLiZeir) Tir-uh‘ltil- er-ittil g Z. Date Called: VA, Special Instructions: fElc9-3._ A /44 Date Wanted: . ....... Requester i Phone No: 1 - zou - '6,- i I 01 EIApproved per applicable codes. Corrections required prior to approval. COMMENTS: APP etE)aNk-c--_ 1iN. L -i2_ Inspector: Date7—i? REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ES -957 957N 957Z For Health Hazard Applications Job Name Tukwila Village Building A Contractor Tri-State Plumbing RECEIVED Job Location 14200 Tukwila International Blvd Approval Engineer Abossein Engineering Contractor's P.O. No DEC 31 2018 Approval Representative TUKWILA LEAD FREE* Series 957, 957N, 957Z Reduced Pressure Zone Assemblies PUBLIC WORKS Sizes: 21/2' -10" (65 - 250 mm) Series 957, 957N, 957Z Reduced Pressure Zon9sernblies-provide protection to the potable water system from cor tamilEiDli LW'tlED FOR cordance with national plumbing codes. Series 9CODE OGWILIANCE normally used in health hazard applications for K rotectio ROVED backsiphonage or backpressure. Features • 21", 3" and 4" (65, 80 and 100mm) sizes ave quarter -turn ball valve shutoffs • Replaceable check disc rubber • Extremely compact design • 70% Lighter than traditional designs • 304 (Schedule 40) stainless steel housing & sleeve • Groove fittings allow integral pipeline adjustment • Patented torsion spring checks provide lowest pressure loss • Unmatched ease of serviceability • Bottom mounted cast stainless steel relief valve • Available with grooved butterfly valve shutoffs 7 i I 1 i Specifications L., The Reduced Pressure Zone Assembly shall con of twoindepen= dent torsion spring check modules, a differential pressure relief valve located between and below the two modules, two drip tight shutoff valves, and required torsion spring check modules and relief valve shall be contained with a sleeve accessible single housing con- structed from 304 (Schedule 40) stainless steel pipe with groove end connections. Torsion spring checks shall have replaceable elastomer discs and in operation produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Assembly shall be a Watts Regulator Company Series 957, 957N, 957Z. FEB 0 6 2019 fable with City of Tukwila BUILDING DIVISIO NOTICE Inquire with governing authorities for local installation requirements *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. CORRECTION LTR# NOTICE 957QT RECEIVED CITY aF TUKWILA CITY DEC 2 8 2018 =ERM T CENTER The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. DI 1/2_ Available Models Suffix: NRS - non -rising stem, resilient seated gate valves OSY - UUFM outside stem and yoke resilient seated gate valves BFG - UUFM grooved gear operated butterfly valves with tamper switch QT - 21/2° - 4" (65 - 100mm) quarter -turn ball valves "OSY FxG - Flanged inlet gate connection and grooved outlet gate connection **OSY GxF - Grooved inlet gate connection and flanged outlet gate connection "OSY GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory** Post indicator plate and operating nut available - consult factory" "Consult factory for dimensions NOTICE When installing a drain line on Series 957 backflow preventers, use 957AG air gaps. See ES-AG/EL/TC for additional information. Dimensions — Weight Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna-N Torsion Spring Checks: NoryP, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Pressure -- Temperature Temperature Range: 33°F -140°F (0.5°C - 60°C) Maximum Working Pressure; 175psi (12.1 bar) 957, 957N, 957Z SIZE (DN) in. mm M. A mm C (OSY) in. mm C (NRS) in, mm 0 in. mm G in. min in. DIMENSIONS 11 mm I m. mm J in. mm M. M mm P r11 mm 957NRS lbs. kgs. WEIGHT 9570SY lbs. kgs, 957N NRS lbs. kgs. 957N OSY lbs. kgs. 21/2 65 303/4 781 16% 416 93/6 238 61/2 165 291/46 738 21'% 546 151/2 393 8'M6 223 211/4 540 9M6 234 118 54 128 58 126 57 136 62 3 80 313/4 806 187/6 479 101/4 260 61/6 170 301/4 768 221/4 565 171/2 435 93/6 233 23 584 101/2 267 134 61 148 67 147 67 161 73 i 4 100 333/4 857 223/4 578 12316 310 7 178 33 838 231/2 597 181/2 470 97$/6 252 2614 667 113/6 284 164 74 164 74 187 85 187 85 6 150 431/2 1105 301/6 765 16 406 81/2 216 443/ 1137 331/2 851 233/6 589 131/46 332 3411 870 15 381 276 125 298 135 317 144 339 154 8 200 493/ 1264 373/4 959 1915/6 506 911/6 246 541/6 1375 401/2 1019 27'/6 697 1511/6 399 36' 937 173/6 437 441 200 483 219 516 234 558 253 10 250 573/4 1467 453/4 1162 2313/16 605 11M6 285 66 1676 491/2 1257 321/2 826 175/6 440 441/2 1124 20 508 723 328 783 355 893 405 950 431 957NBFG, 957ZBFG _ SIZE (DN) _.. in. MI _ _ in. G mm in. H mm in. 0NSIDNS I mm in. J mm in. M mm in. P nim .,, VVOGNF 957N/957Z lbs, kgs. 21/2 65 321/2 826 23 584 151/2 394 9% 241 193/4 502 1113/16 300 67 30 3 80 34 864 24 610 165/6 414 101/16 256 211/4 540 121/6 308 70 32 4 100 355/6 905 251/2 648 17316 437 1015/6 279 231/2 597 12%6 321 87 39 6 150 461/2 1181 351/4 895 201/2 521 1312 343 271/4 692 15 382 160 73 Noryl® is a registered trademark of SABIC Innovative Plastics Holding BV, • Approved by the Foundation for Cross -Connection Control and Hydraulic Research at The University of Southern Califomia (FCCCHR-USC) (Excluding 'N' Pattern - 10", 'Z' Pattern - 6" and 10") • AWWA C551-92 v.ss,„ 4P® 0. 4:0 C ®US Approved US 1013 664.4 (**BFG & OSY Only) Dimensions — Weight continued ioniNn1 to NSF;ANSI 61,1 957BFG SIZE (DN) in. mm A in. mm DIMENSIONS c in. mm D M. mm For additional approval information please contact the factory or visit our website at www,watts.com P in. mm 4 100 6 150 29 737 73/4 197 6% 162 9'/2 241 361/2 927 911/16 246 7%6 189 14'/4 362 WEIGHT lbs. kgs. 66 30 122 55 957QT P 11 G SIZE(DN) A C D G H :DIMENSIONS I J M P P1 - QT WEIGHT • QTN in. mm in. mm in. mm in. mm in. min in. mm in. mm in. mm in. mm in. inm in. mm lbs. kgs. lbs. kgs. 21/2 65 271/2 698 47/8 124 67/8 175 301/4 768 21% 546 16'/16 407 11% 289 197/8 505 115/6 287 115/6 287 46 21 57 26 3 80 28 711 47/8 124 67/s 175 301/4 768 221/4 565 169/ 6 420 11% 289 20718 531 11 %i s 297 1155%6 287 56 25 67 30 4 100 283/4 730 47/8 124 67/8 175 30'/4 768 23Y2 597 185/16 4651 113/8 289_ 24318 619 11%6 287 115/16 287 76 34 87 39 Capacity Series 957, 957N, 957Z flow curves as tested by Underwriters Laboratory. Flow characteristics collected using butterfly shutoff valves E 5 10 g 0. c CCa a 10 � Horizontal N -Pattern Z-Pattem 21/2" (65mm) Service Row Rated Flow V. Rated Flow 6 0 0 psi 16 14 12 8 6 psi 26 22 18 14 10 6 psi 25 20 a a- 15 • = E, 10 E 5 0 0 0 Z N H 50 100 150 200 250 300 350 gpm 190 380 570 760 950 1140 1330 Ipm 7.5 15 fps 3" (80mm) Rated Row *11L Rated Row 0 100 200 0 380 760 7.5 300 400 500 gpm 1140 1520 1900 Ipm 15 fps 4" (100mm) Service Row Rated Row "UL Rated Flow Z N H 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 Ipm 7.5 13 fps 4" BFG (100 mm) Horizontal Service Flow Rated Row "UL Rated Flow 100 200 300 400 500 600 700 800gpm 380 760 1140 1520 1900 2280 2680 30401pm 7.5 13 fps Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. N a of 0 0 ILtcriE psi 18 16 14 12 10 8 6 psi 18 16 14 12 10 8 6 0 0 6" (150mm) Service Row Rated Row 'UL Rated flow .rAg� H 300 600 900 1200 1500 gpm 1140 2280 3420 4560 5700 Ipm 7.5 12 fps 8" (200mm) Service flow Rated Row 'UL Rated ow N H psi 16 14 ▪ 12 0 10 8 oJ oz 7)V a � i 6 4 0 0 500 1000 1500 2000 2500 gpm 1900 3800 5700 7600 9500 Ipm 7.5 10 fps 10" (250mm) Service Row Rated Row 'UL Rated Row z N r Psi 16 14 12 10 8 6 4 2 0 0 0 H 500 1000 1500 2000 2500 3000 3500 gpm 1900 3800 5700 7600 9500 11400 13300 Ipm 7.5 10 fps 6" BFG (150 mm) Horizontal Service Row Rated Row *UL Rated Row 200 400 600 800 1000 1200 1400 1600gpm 760 1520 2280 3040 3800 4560 5300 6060 Ipm 7.5 12 fps ES -957 957N 957Z 1806 USA: Tel: (978) 689-6066 • Fax: (978) 975-8350 • Watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 • Watts.com © 2018 Watts 10/1/2019 r �. City of Tukwila Department of Community Development DAVE VAN DUINE 6505 233 PL SE WOODINVILLE, WA 98072 RE: Permit No. PG 18-0142 TUKWILA VILLAGE BUILDING A 14200 TUKWILA INTERNATIONAL BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/16/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/16/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: PGI8-0142 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not he accepted through the mail, fax, etc. Date: 17— 2-7 12-0)1c Plan Check/Permit Number: 'PCA ' 014 2— ❑Ell] Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # RECEIVED CITY OF TUKWILA DEC 2 8 2018 PERMIT CENTER Project Name: , ► 1,3.., U ; i ` e- \ u_, li�� `i t,.,l��i7 1 7--C9n T � Project Address: v�.1Lu3 ►1 CA-�i� i -e r� ¥i e ai �\ 13kv& l Contact Person: Vim\) Q___,V `r (.L,,,-.\-0,-, ---f\e Phone Number: Lk 7.S &Li -3 3s--30 Summary of Revision: e—vC5P.R__-V-0_--A-c,_,- \ V\' S1\e--4 Pit. © csLAc9, Sheet Number(s): L. (\_c_ V) 3, Cr) "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: %1w Entered in TRAKiT on 1 (,/( r W:`,Pe nit Center\Templates\Fonas\Revision Submittal Form.doc Revised: August 2015 City of Tukwila Department of Community Development December 13, 2018 DAVE VAN DUINE 1624 135 PL NE BELLEVUE, WA 98005 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG 18-0142 TUKWILA VILLAGE BUILDING A - 14200 TUKWILA INTERNATIONAL BLVD Dear DAVE VAN DUINE, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW - PG DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Detail A/P 1 on sheet P1.0 and Parking Level 1 (Aboveground) Plumbing Plan on sheet P3.0 call for a Reduced Pressure Backflow, which needs to be a Reduced Pressure principle Assembly (RPPA). RPPA shall be a WA State Dept. of Health approved backflow. Please specify on plan, the size, manufacturer, model no. of proposed RPPA and include RPPA cut sheet. Circle backflow to be installed on the cut sheet. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. PG I8-0142 41) 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 =PERMIT COORD COPY C PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0142 DATE: 12/28/18 PROJECT NAME: TUKWILA VILLAGE BUILDING A SITE ADDRESS: 14200 TUKWILA INTL BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division 1) (7 AVG 1\I°i Public Works Fire Prevention Structural Planning Division nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 1/01/19 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 1/29/19 Approved Corrections Required n Approved with Conditions n n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 'Pt AjERMI COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG18-0142 DATE: 12/6/18 PROJECT NAME: TUKWILA VILLAGE BUILDING A SITE ADDRESS: 14200 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Auci V.-1 —le Building Division M CoviZ Public Works Fire Prevention Structural Planning Division Pennit Coordinator 111 PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/11/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Denied (corrections entered in Reviews (ie: Zoning Issues) Approved with Conditions DUE DATE: 1/08/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 1? -713'1 Departments issued corrections: Bldg 0 Fire Ping PW Staff Initials: 12/18/2013 TRI-STATE PLUMBING INC Washington State Department of Lab©r & Industries !-tome Espanol Contact Safety & Health Claims & Insurance / V, [Search L&i Page 1 of 5 A -Z i ndex Hclp viy L&l' Workplace Rights Trades & Licensing TRI-STATE PLUMBING INC Owner or tradesperson Principals QUACKENBUSH, WILLIAM J, PRESIDENT MICHAEL, GARY V, VICE PRESIDENT GOODMAN, WILLIAM E, VICE PRESIDENT DARNELL, FRED N, VICE PRESIDENT (End: 09/03/2002) ARNONE, CHARLES J, VICE PRESIDENT (End: 09/03/2002) CANON, PAUL E, VICE PRESIDENT (End: 09/13/2010) MICHAEL, GARY V, VICE PRESIDENT (End: 09/13/2010) Doing business as TRI-STATE PLUMBING INC WA UBI No. 600 151 772 6505 233RD PL SE WOODINVILLE, WA 98072 425-643-3830 KING County Business type Corporation Governing persons WILLIAM J QUACKENBUSH PAUL E CANON; GARY . MICHEAL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. TRISTI*245NZ Effective — expiration 08/09/1976-10/01/2020 Bond Lexon Ins Co Bond account no. 9816460 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 04/26/2013 04/20/2013 Expiration date Until Canceled Bond history Insurance Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600151772&LIC=TRISTI*245NZ&SAW= 2/14/2019