Loading...
HomeMy WebLinkAboutPermit EL18-0292 - RILEY ROSE - CONNECT TO ELECTRICAL SERVICE AND INSTALL TRANSFORMER AND PANELSThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL18-0292 RILEY ROSE LLC 467 SOUTHCENTER MALL THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemptio (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION defExplanatory Description S a u el ule DR1 Personal Information — Social Security Numbers Generally — 5 U.S.C. sec. 552(a); RCW 42.56.070(1) The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those individuals' privacy pursuant to 5 U.S.C. sec. 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. 5 U.S.C. sec. 552(a); RCW 42.56.070(1) 20 DR2 Personal Information — Financial Information — RCW 42.56.230(4 5) Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit expiration dates, or bank or other financial account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. RCW 42.56.230(5) DR3 Personal Information — Driver's License. — RCW 42.56.230 (7a & c) Redactions contain information used to prove identity, age, residential address, social security number or other personal information required to apply for a driver's license or identicard. RCW 42.56.230 (7a & c) DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW 42.56.070(1) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney-client privileged communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. RCW 5.60.060(2)(a); RCW 42.56.070(1) This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL18-0292 RILEY ROSE LLC 467 SOUTHCENTER MALL THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemptio (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION defExplanatory Description S a u el ule DR1 Personal Information — Social Security Numbers Generally — 5 U.S.C. sec. 552(a); RCW 42.56.070(1) The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those individuals' privacy pursuant to 5 U.S.C. sec. 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. 5 U.S.C. sec. 552(a); RCW 42.56.070(1) 20 DR2 Personal Information — Financial Information — RCW 42.56.230(4 5) Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit expiration dates, or bank or other financial account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. RCW 42.56.230(5) DR3 Personal Information — Driver's License. — RCW 42.56.230 (7a & c) Redactions contain information used to prove identity, age, residential address, social security number or other personal information required to apply for a driver's license or identicard. RCW 42.56.230 (7a & c) DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW 42.56.070(1) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney-client privileged communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. RCW 5.60.060(2)(a); RCW 42.56.070(1) RILEY ROSE, LLC 467 SOUTHCENTER MALL ELI 8-0292 Parcel No: City of Tukwila a ofAddress: --,-'--_'Community Development 6300 Southcenter Boulevard, Suite #100 Tukwlla, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://wwwjukwllaWA.gov 9202470010 467 SOUTHCENTER MALI. Project Name: RILEY ROSE, LLC ELECTRICAL PERMIT Permit Number: EL18'0392 Issue Date: 7/5/2018 Permit Expires On: 1/1/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: WESTFIELD PROPERTY TAX DEPT PDBOX 13O940,[ARLS8AD CA, 92013 ABEL LOPEZ 38OOmMISSION ROAD ' LOS ANGELES, CA, 90031 ACT -ON -ELECTRIC Address: PO BOX 2118 , LYNNWOOD, WA, 98036 License No: ACTEL**311LE Lender: Name: Address: ' Phone: (213) 765-2978 Phone: (206) 786-3946 Expiration Date: 12/31/2019 DESCRIPTION OF WORK: CONNECTING TO EXISTING ELECTRICAL SERVICE AND INSTALLING NEW TRANSORMER AND ELECTRICAL PANELS. NEW LIGHT FIXTURES ARE TO BE INSTALLED AND POWER OUTLETS. Valuation of single family: 50,00 Valuation of mf/comm: $38356.00 Type of Work: TENANT IMP Fees Collected: $1,040.87 Electrical Servce Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 20172017 2015 ZS(ik Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regul. ' g con tructi o the performance of work. I am authorized to sign and obtain this development per.nd.gre to h: con tions attached to this permit. Date: r This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Conununity Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: (For of ce use on ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 467 Southcenter Mall Tenant Name: Riley Rose, LLC PROPERTY OWNER Name: Abel Lopez Address: 3880 N. Mission Road Name: Westfield Phone: (213) 765-2978 Fax: Email: abel.l@forever21.com Address: 467 Southcenter Mall City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Abel Lopez Address: 3880 N. Mission Road City: Los Angeles She: CA Zip: 90031 Phone: (213) 765-2978 Fax: Email: abel.l@forever21.com King Co Assessor's Tax No.: Suite Number: 1545 Floor. First New Tenant: J Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 38,355 Scope of Work (please provide detailed information): Connecting to existing electrical service and installing new transformer and electrical panels. New light fixtures are to be installed and power outlets. Will service be altered? ❑ Yes ® No Adding more than 50 amps? Yes ❑ No Type of Use: Mercantile Type of work: O New ❑ Addition 0 Service Change ❑ Low Voltage ❑ Generator 0 Fire Alarm Property Served by: VA Puget Sound Energy ❑ Seattle City Light W:1Pen it Cer i pplieeiawnaidort, F+ernii ApplicaioeslPDFaElecnicel Paoli Applicaup Revised 1.1.17.dou Revised: Jemmy 7017 6h ❑ Remodel 0 Telecommunication Tenant Improvement 0 Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings 583.54 ea ❑ Low voltage systems (alarm, fumace thermostat) 561.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 583.54 (no added/altered circuits) ❑ Service change with added/altered circuits 583.54 number of added circuits 512.00 ea ❑ Circuits added/altered without service change 555.69 (up to 5 circuits) ❑ Circuits added/altered without service change 555.69 (6 or more circuits) S7.65 ea ❑ Meter/mast repair 569.62 ❑ Low voltage systems 561.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. NIISCELLANEOUS FEES ❑ Temporary service (residential) 566.30 ❑ Temporary service (generator) 582.52 ❑ Manufactured/mobile home service 587.98 (excluding garage or outbuilding) ❑ Carnivals 582.21 Number of concessions S11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Abel Lopez Mailing Address: abel.l@foreveer21.com Date: 03/23/2018 Day Telephone: (213) 765-2978 Los Angeles CA 90031 City W Temit Centel Appbcatiots-R douts'Pernat Applicatieas?PDrs`.Electrical Permit Application Roised 1.1-17.docx Revised: January 2017 bh State Zip Page 2 of 2 (o( as Ch Register Receipt City of Tukwila Receipt Number R14618 DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $5,498.00 D18-0093 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $3,731.53 DEVELOPMENT $3,579.01 PERMIT FEE R000.322.100.00.00 0.00 $3,050.41 PLAN CHECK FEE R000.345.830.00.00 0.00 $524.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $152.52 TECHNOLOGY FEE R000.322.900.04.00 1 0.00 $152.52 EL18-0292 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $840.70 ELECTRICAL $800.67 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $800.67 TECHNOLOGY FEE $40.03 TECHNOLOGY FEE R000.322.900.04.00 1 0.00 $40.03 M18-0040 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $746.38 MECHANICAL $710.84 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $677.69 TECHNOLOGY FEE $35.54 TECHNOLOGY FEE R000,322.900.04.00 0.00 $35.54 PG18-0048 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $179.39 PLUMBING $170.85 PERMIT FEE R000.322.100.00.00 0.00 $137.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.54 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.54 TOTAL. FEES PAID BY RECEIPT: R14618 . $5/498.00 Date Paid: Thursday, May 31, 2018 Paid By: JAMES E JOHN CONSTRUCTION CO Pay Method: CHECK 71559 Printed: Thursday, May 31, 2018 2:25 PM 1 of 1 Cash Receipt Register of Tukwila City Receipt- Number R14091 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY : PAID $1,879.26 D18-0093 Address: 467 SOUTHCENTER MALI Apn: 9202470010 $1,458.67 DEVELOPMENT $1,458.67 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,458.67 EL18-0292 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $200.17 ELECTRICAL $200.17 PLAN CHECK FEE R000.345.832.00.00 0.00 $200.17 M18-0040 Address: 467 SOUTHCENTER MALI Apn: 9202470010 $177.71 MECHANICAL $177.71 PLAN CHECK FEE R000.322.102.00.00 0.00 $17/.71 PG18-0048 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $42.71 PLUMBING $42.71 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14091 R000.322.103.00.00 0.00 $42.71 $1,879.26 Date Paid: Tuesday, March 27, 2018 Paid By: RILEY ROSE LLC Pay Method: CHECK 600248 Printed: Tuesday, March 27, 2018 2:56 PM 1 of 1 141"!LMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43 Permit lnsp tion Request Line (206) 438-9350 Project: fy Type of Inspection: Aif Address: (i.7 Alit/ Date Called: • Special instruction : Date Wanted: 10A-7 l'.-r.,t/** Requester: Phone No: jijApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Vc104/5 fifroE Date: tc2/21/1. REINSPECTION FEE REQUIRED. Prior to next inspection, fe must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSP TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-30 Permit Inspection Request Line (206) 438-9350 Project: ( L .. 0 ( Type nspection: , /r--". ov161 4- IP•17 Mtn_ Address:Date 11‘ I it" C led: Special Instructi s: Date Wanted: 1 0/ (ifr,a.rrtil. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. tOMMENTS: 0 --. 1. . ,--- etC1 (.4(JC CD t45\ \- -- O P6iJ M 1)cM LA C/ Pio (-6: - e„pe,e-re pAArei__ Scm 64>AL-5, ni &Oi-v-x1-4 , 6 lotie krJ b is g.„ CAzw4Nt1-5 Inspector: Date: 1014 47 REINSPECTIONFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit 6k INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367 Project: r 6 TypRbof Irp iont:A/(..1 - C— pikirs 3!zietilcA4- e_tex.,ifr5 -coto 6‘ Address: r Ille 1130 V PtiAlt C.- Dale Lalled: DifiZfrit 0 vre-ek 1 Ctie-k-i-4A Pr 042Li 1 AA Specialnstru s: Date Wanted: 17 el7rti,. p.m. Requester: -- A Phone No: ElApproved per applicable codes. 174 Corrections required prior to approval. COMMENTS: Inspector: _3 irtfj k6-akat 3 P*frts - C— pikirs 3!zietilcA4- e_tex.,ifr5 -coto 6‘ 6 LAI e r Ille 1130 V PtiAlt C.- 14 DifiZfrit 0 vre-ek 1 Ctie-k-i-4A Pr 042Li 1 AA DNA-rvg4 of 010.h r5 ,-',7 tl I j _ . . 1,.)k -D6 -ii -Jere Fp ase.) dJr)u t. -- A Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: ( Ds Le Type of Inspection: PIA id Address: '/1,7riAlit/ Date Called: Special lnstructi s: Date Wanted: ?7/0ti p.m. Requester: Phone No: EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: 14A-9 1,--p Inspector: &AJk Date: REINSPECTION EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43 - Permit Inspection Request Line (206) 438-9350 Project: tr / XP5E Type of Inspection. Dki /Ai Address: Lil Date Called: Special Instructions: , Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: AtA4)6QJ ATE Co 4t) r 5 v PPa_-r - 4( &I•vb Inspector: Ill/ t5svii6ik Date: 07Aipp REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4 Permit Inspection Request Line (206) 438-9350 Project: T c o5c= Type of Inspection: Dvtki+ iii Address: 11(0/ /U/ Date Called: CiSli,tilf.‘ t" h2eS Vc6i) Ek._ sLiPP012-1--- Special Instructio s: Date Wanted: P.m.' Requester: — &JOT Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: - CA654/07- J56 GoA11)%1Ir TI) 5 Ala- vic,ri...4.5c CA--/),LA-65 D kflf-LAQ CiSli,tilf.‘ t" h2eS Vc6i) Ek._ sLiPP012-1--- Tv1E EcAia--6-1) It -i A-bb1 ram/ Al____ riC, 5UPPDET- R-f-Qtic it.L'9 — &JOT — A Inspector: NA 64\16c Date: 007a REINSPECTION IEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 to? Project: (j I fr1056 Type of Inspection: Li i /10044-/A/ Address: 14)7 11 Date Called: Special Instructions: ' Date Wanted: p.m; 7/E). Requester: Phone No: ElApproved per applicable codes. COMMENTS: ,,Corrections required prior to approval. Aior g(A-D Alkt) arJ ic, cs-up 061 -- bo Jr FT/A-P To 64D tit r k ra-tni A-cec5 ReC101 e.,C)> Inspector: Date: 0 11/1 REINSPECTION EE REQUIRED. Prior to next inspectio , fee Jiust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. J INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 6-6)-0mi Ito Project: 111 K v, C Type Insp tir o ,r): 4 f IA Address: '16, 11 kl�l/ Called: Special Instructio s: CJ , v / t� L 1�P-- CMA/ RA') Date Wanted: a.rx- Requester: Phone No: 206 'L, 5-7r 0 Approved per applicable codes. u Corrections required prior to approval. OMMENTS: Inspector: Date: Yap REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2 - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 'ff. , Art.c1 RPS6 Type of Inspection: 3 t 4..,Vil e. Aeddress: q (01 riAt Date Called: 3. Cif Lf&o 61,-r- Instructio s: Date Wanted: g.n.Special ,/,0 2.,- .... Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ,--- Fo k )MI‘ c.Stuabireol ,Ko 3. Cif Lf&o 61,-r- _ po_atbe .-I f�& ttEu /61,r- Pkoia, inspector Date: oglol" tN8 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 "ea L 2.9 Project: aLle 'R.-0 ..e.. per applicable codes. Type of Inspection: L' & rk 10 Address: -7 Crit Plett4 Date Called: Special Instructions: l't Let e2 -{IC 7Gc Date Wanted: a.m. P.m. Requester: Ill ?Phone cc - Iti-c-r Oone-g-reroved No: iApp sm Corrections required prior to approval. C ENTS: Q A1 1-c;67C1e GI 39 LiA iv Ei7, (9re2444 Inspecto Date: 7/6// REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0292 DATE: 04/02/18 PROJECT NAME: RILEY ROSE, LLC SITE ADDRESS: 467 SOUTIICENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Atuc Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator LI PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/03/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: Approved Approved with Conditions Corrections Required Fl Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: LI 05/01/18 REVIEWER'S INITIALS: DATE: Permit Cotter Uze On. CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 ACT -ON -ELECTRIC C) Washington State Department of Labor & Industries Homel.spanol ConUct Safety & Health Claims & Insurance Search L&I Page 1 of 2 AAR A -Z Indox 1 leIp My 1,&I Workplace Rights Trades & Licensing ACT -ON -ELECTRIC Owner or tradesperson Principals CASHEN, JOHN E JR, OWNER Doing business as ACT -ON -ELECTRIC WA UBI No. 319 011 211 PO BOX 2118 LYNNWOOD, WA 98036 206-786-3946 SNOHOMISH County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. ACTEL**311LE Effective — expiration 06/05/1969— 12/31/2019 Designated administrator CASHEN, JOHN F JR License type Master Electrician Bond No bond accounts during the previous 6 year period. Savings (in lieu of bond) Received by L&I 08/22/2012 Release date N/A Savings account ID Savings history License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. CASHEJF972DS $4,000.00 Effective date 08/22/2012 Impaired date N/A IFVorkers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 357,762-00 Doing business as Account is current. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=319011211&LIC=ACTEL**311LE&SAW= 7/5/2018 ACT -ON -ELECTRIC ACT ON ELECTRIC; Estimated workers reported Quarter 1 of Year ..018 "1 to 3 Workers" L&I account contact T1 / LINDSEY BOL TH (360)902-5596 - Email: B000235@lni.wa.gov Public Worts Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strike:- No strikes have b. an issued against this contractor. Contractors not a owed to bid No debarments h e been issued against this contractor. Workplace :safety and health No inspections dur;.,g the previous 6 year period. Page 2 of 2 ©Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni va.gov/verify/Detail.aspx?UBI=319011211&LIC=ACTEL**311LE&SAW= 7/5/2018 1 VICINITY MAP E000 SCALE: NONE 2 . KEY PLAN E000 SCALE: NONE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittat and may include additional plan review fees. j FILE COPY a Permit No. -L-1 v - 0)--.9), Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or • : e. Receipt of approved Field C • • }, : ' d • • ' + : cknowledged• iii01 By: Date: City of Tukwila BUILDING DIVISION 15:7-PARATE PERMIT RoQIPiE.D FOR: jechanicai E)otrical c LPlumbing s Piping of Tukwila ING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES; CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT© RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: EVEL 1 ENGINEER S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 w U I J J 2 I w Z w 0 1 1- 0 0) ti c0 ISSUANCE DESCRIPTION w 0 z SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME VICINITY MAP & KEYPLAN DWN BY: EFO CHK BY: EJR SHEET NUMBER E000 SCALE: NONE ABBREVIATIONS A ADA AFC AFF AFG ANSI ARCH AUX AWG A/V AMP, AMPERES AMERICANS WITH DISABILITIES ACT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMERICAN NAT'L STANDARDS INSTITUTE ARCHITECT, ARCHITECTURAL AUXILARY AMERICAN WIRE GAUGE AUDIO/VISUAL BAS BKR BLDG BMS BUILDING AUTOMATION SYSTEM BREAKER BUILDING BUILDING MANAGEMENT SYSTEM C CATV C/B CCTV CFM CKT CT CLG CW CONDUIT CABLE TELEVISION SYSTEM CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CUBIC FEET PER MINUTE CIRCUIT CURRENT TRANSFORMER CEILING COLD WATER D dB DDC A DIA DISC DN DWG DEEP, DEPTH DECIBEL DIRECT DIGITAL CONTROL DELTA DIAMETER DISCONNECT DOWN DRAWING EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ETR EXISTING TO REMAIN EMT ELECTRICAL METALLIC TUBING EWC ELECTRICAL WATER COOLER EXH EXHAUST EX, EXIST EXISTING FA FACP FARA FLA FPC FT FIRE ALARM FIRE ALARM CONTROL PANEL FIRE ALARM REMOTE ANNUNCIATOR FULL LOAD AMPS FIRE PROTECTION CONTRACTOR FOOT, FEET G,GRD GROUND GC GENERAL CONTRACTOR GFI, GFIC GROUND FAULT INTERRUPTER HID HTR HVAC HIGH INTENSITY DISCHARGE HEATER HEATING, VENTILATING & A/C IBC IN INTERNATIONAL BUILDING CODE INCH, INCHES KVA KW KWH KILOVOLT -AMPS KILOWATTS KILOWATT-HOUR L LED LRA LTG LENGTH LIGHT EMITTING DIODE LOCKED ROTOR AMPS LIGHTING MAX MC MCA MCB MCC MECH MH MIN MOCP MUA MTD MAXIMUM MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MECHANICAL METAL HALIDE MINIMUM MAXIMUM OVER CURRENT PROTECTION MAKE UP AIR MOUNTED N/A N.C. NEC NEMA NFPA NIC N.O. NTS NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATIONAL ELECTRICAL MFR'S ASSOC. NATIONAL FIRE PROTECTION ASSOC. NOT IN CONTRACT NORMALLY OPEN NOT TO SCALE 00 0/H OSHA ON CENTER OVERHEAD OCCUPATIONAL SAFETY &HEALTH ADMIN. PB PC PF PH PVC POLE PUSH BUTTON PLUMBING CONTRACTOR POWER FACTOR PHASE POLYVINYL CHLORIDE RCP REV REX RGS RLA RM RR RTU REFLECTED CEILING PLAN REVISION REMOVE EXISTING RIGID GALVANIZED STEEL RUNNING LOAD AMPS ROOM REMOVE AND RELOCATE ROOF TOP UNIT SE SF SERVICE ENTRANCE SQUARE FEET, SQUARE FOOT THRU TRANS TYP T/C THROUGH TRANSFOMER TYPICAL TIME CLOCK UG UL UON UPS UNDERGROUND UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED UNINTERRUPTABLE POWER SUPPLY V VA VOLT VOLT-AMPERE W W/ WP XFMR WATT, WIDTH WITH WEATHERPROOF TRANSFORMER Y WYE ELECTRICAL SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS) 1,3,5 HOMERUN TO PANEL "A", CIRCUIT #1,3,5 (VIA 20A -1P CIRCUIT BREAKERS), TWO #12 CONDUCTORS (MINIMUM SIZE), UON. A GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL CONDUITS. REFER TO SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS. INFLOOR/UNDERFLOOR CONDUIT/WIRE 0 CIRCUITRY TURNING UP V PANELBOARD - 208Y/120 VOLT, 30, 4 WIRE PANELBOARD - 480Y/277 VOLT, 30, 4 WIRE ,l • TELEPHONE FIRE RATED PLYWOOD BACKBOARD - SIZE INDICATED ON PLAN J Y JUNCTION BOX DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH FUSED: "AS" - INDICATES AMPERE SWITCH SIZE "AF" - INDICATES AMPERE FUSE SIZE DRY TYPE TRANSFORMER 0 DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED: "2" INDICATES CIRCUIT NUMBER 'C' INDICATES MOUNTED 8" ABOVE COUNTER ' 54" INDICATES 54" AFF "WP" INDICATES WEATHERPROOF COVER "IG° INDICATES ISOLATED GROUND TYPE 'GFI' INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE 0 ®I® DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. SINGLE (SIMPLEX) RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRAWINGS. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN CEILING. COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. Q FIRE RATED POKE -THROUGH DEVICE "P" INDICATES DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE °T" INDICATES TELEPHONE/DATA SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1 -HP RATED, 20 AMPERE, MOUNTED AT 48° AFF UNLESS OTHERWISE NOTED: '3' INDICATES THREE WAY SWITCH "4" INDICATES FOUR WAY SWITCH "C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER ' a" INDICATES SWITCHED FIXTURE CONTROL 'OS" INDICATES DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH 'DM" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR OS OCCUPANCY/VACANCY SENSOR - DUAL TECHNOLOGY, CEILING MOUNTED - SINGLE POLE, TOGGLE TYPE - 120/277 VOLT, 20 AMPERE "3" INDICATES THREE WAY SWITCH "4" INDICATES FOUR WAY SWITCH AQ L-3 AQE QQ NL L-2 TC LIGHT FIXTURE - REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. "AO" INDICATES FIXTURE TYPE "L" INDICATES PANEL "3" INDICATES SWITCHED CIRCUIT NUMBER LIGHT FIXTURE - REFER TO LUMINAIRE SCHEDULE FOR DESCRIPTION. CONNECT LIGHT FIXTURE EMERGENCY BALLAST TO UN -SWITCHED CIRCUIT TO MAINTAIN CONSTANT POWER AND CONNECT NORMAL BALLAST TO SWITCHED CIRCUIT FOR ON/OFF CONTROL. "AQ" INDICATES FIXTURE TYPE 'E' INDICATES FIXTURE WITH BATTERY "L" INDICATES PANEL "2" INDICATES CIRCUIT NUMBER "NL" INDICATES FIXTURE CONNECT UN -SWITCHED CIRCUIT AND ALWAYS ON. ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE - CEILING MOUNTED OR WALL MOUNTED. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE - CEILING MOUNTED OR WALL MOUNTED. PROVIDE FACES DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. REFER TO LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION. REMOTE EMERGENCY WEATHERPROOF LIGHTING HEAD SUPPLIED FROM REMOTE BATTERY UNIT. EMERGENCY LIGHTING BATTERY UNIT WITH HEADS AS INDICATED. TIME CLOCK COMBINATION VOICE/DATA OUTLET - MOUNTED AT 18° AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. °W" INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED 8° ABOVE COUNTER. DATA OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4° CONDUIT TO ABOVE THE ACCESSIBLE CEILING. °W' INDICATES WALL MOUNTED AT 54" AFF, °G" INDICATES MOUNTED 8° ABOVE COUNTER. VOICE OUTLET - MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. 'W" INDICATES WALL MOUNTED AT 54" AFF, 'C" INDICATES MOUNTED 8" ABOVE COUNTER. DOOR BELL PUSHBUTTON C)/FIRE ALARM DUCT MOUNTED SMOKE DETECTOR WITH SAMPLING TUBE, FURNISHED AND WIRED BY EC, MOUNTED BY MC. REMOTE ANNUNCIATOR LIGHT/AUDIBLE ALARM FOR DUCT SMOKE DETECTOR FIRE ALARM CONTROL PANEL FIRE ALARM EXTENDER PANEL FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF. FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80" AFF. FIRE ALARM AUDIO/VISUAL ALARM SIGNAL CEILING MOUNTED, REFER TO PLANS FOR MOUNTING HEIGHT IN OPEN CEILING AREAS FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80' AFF. FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR FIRE ALARM HEAT DETECTOR FACP FAEP CEILING FIRE ALARM HORN/STROBE FIRE ALARM MANUAL PULL STATION MISCELLANEOUS TELEPHONE OUTLET THERMOSTAT RECEPTACLE WALL SWITCH DATA OUTLET FINISHED FLOOR 0 96" MAXIMUM 48" MAXIMUM UNLESS LOCATED ABOVE "OBSTRUCTION" SUCH AS A COUNTER, THEN 42 MAXIMUM 0 80° MINIMUM —o 0 18" MINIMUM 1 TYPICAL MOUNTING HEIGHTS (UON) E001 SCALE: NONE FIGURE 1 a FIGURE 2 PENETRATE MAX. DEPTH NOMINAL UL SYS. SIZE REQ'D ANNULUS NO. STEEL PIPE OR CONDUIT 6' 1" 11/16" CAJ1090 IRON, STEEL PIPE OR CONDUIT, EMT, OR COPPER PIPE OR TUBING 4" 3/4" 3/4" WJ1025 FIGURE 3 1® CONCRETE OR CONCRETE BLOCK WALL. O METALLIC PIPE, CONDUIT OR TUBING (SEE FIG. 3) ® SPECSEALR®PUTTY. SEE FIGURE 3 FOR MORE INFORMATION. (4 FIBERGLASS FORMING MATERIAL PACKED INTO WALL CAVITY. ALL PRODUCTS AND INSTALLATION SHALL MEET: • ASTM E814 (UL1479). REFER TO SYSTEM NUMBERS CAJ-1900 & WJ-1025 • ASTM E119 (TIME/TEMPERATURE EXPOSURE) (COTTON WASTE IGNITION) • ANNULAR SPACE REQUIREMENTS. 0 4 2 HOUR FIRESTOP FOR METALLIC PIPING CONCRETE WALL E001 SCALE: NONE 1=10„ 1=10„ t -4„ 3'-4" �x 7 CASH/BACKWRAP DETAIL E001 SCALE: NONE 7 CASH/BACKWRAP DETAIL E001 SCALE: NONE • • • CIRCUIT STEEL STUD CONDUIT (EMT) 3M FIRE BARRIER MOLDABLE PUTTY. OUTLET BOX OUTLET BOX 3M FIRE BARRIER MOLDABLE PUTTY. • STEEL STUD CONDUIT (EMT) 1 OR 2 HOUR FIRE RATED GYPSUM WALL BOARD ASSEMBLY. 2 OUTLET BOX IN FIRE RATED WALL E001 SCALE: NONE PANELBOARD 480/277V (TYP,) 3P BREAKER O 0 O 0 Q NEUTRAL BAR DRY TYPE TRANSFORMER PANELBOARD 208/120V 1- Li! CC Q CO 0 CC cs MAIN BREAKER 0 0 O� 1NEUTRAL BAR EQUIPMENT GROUND '1 0'i r. 0 0 CONDUIT GROUND 0 DETAIL KEYNOTES 1 GROUNDED (NEUTRAL CONDUCTOR): SIZE AS INDICATED ON ONE LINE. 2 GROUNDED ELECTRODE: SIZE AS INDICATED ON ONE LINE. 3 BONDING JUMPER: SIZE AS INDICATED ON ONE LINE. 4 ISOLATED GROUND: SIZE AS INDICATED ON ONE LINE. 0 EFFECTIVELY GROUNDED BUILDING STEEL COLUMN ACCESSIBLE EXOTHERMIC CONNECTION 5 DRY TYPE TRANSFORMER GROUNDING AND ISOLATED GROUND DETAIL E001 SCALE: NONE DRIVER AWG WIRE RUN 8 DRIVER WIRING DIAGRAM E001 SCALE: NONE EQ EQ 9 MONITOR DETAIL E001 SCALE: NONE GYPSUM WALL BOARD ASSEMBLY MINERAL WOOL PACKING BATT, NOMINAL 4 PCF, DEPTH AS REQUIRED BY THE MANUFACTURER METALLIC CONDUIT 1 OR 2 HOUR RATED UL #WL3001 INTUMESCENT FIRESTOP SEALANT, DEPTH AS REQUIRED BY THE MANUFACTURER 3 FIRESTOP FOR METALLIC CONDUIT -GYPSUM WALL E001 SCALE: NONE PANELBOARD 208/120V CONNECT TO THE MAIN SERVICE GROUNDING POINT CONDUIT GROUND 0 Q DETAIL KEYNOTES 1 GROUNDED (NEUTRAL CONDUCTOR): SIZE AS INDICATED ON ONE LINE. 2 GROUNDED ELECTRODE: SIZE AS INDICATED ON ONE LINE. 3 ISOLATED GROUND: SIZE AS INDICATED ON ONE LINE. 6 ISOLATED GROUND DETAIL EOO1 SCALE: NONE REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC APR 122010 City of.Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2.7 2018 PERMIT CENTER L( 02 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT O RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 35588 • 'ecl�Tr ONA 4.7 W zi-4) wL4-' C� Q c:t) yWQ U W J F � 0 ci) z z 0 H a 0 z 0 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME ELECTRICAL LEGEND DETAILS DWN BY: EFO CHK BY: EJR SHEET NUMBER E001 SCALE: NONE 8 (E) ADJACENT TENANT (N.I.C) 125A ODISCONNECT SWITCH (ETR) (::)PANEL HP (ETR) •\ • ===___ `s 9 r�� I1 45kVA TRANSFORMER (REX)() PANEL LP (REX) PANEL PP (REX) —r' -, GENERAL SHEET NOTES A. PRIOR TO ANY EXECUTION OF WORK, THE CONTRACTOR SHALL MEET WITH THE OWNER/ARCHITECT TO DISCUSS SCOPE OF DEMOLITION WORK. B. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS, OR DEMOLITION THE CONTRACTOR SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. C. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY BY DISCONNECTING, CUTTING, AND MAKING SAFE ALL DEMOLITION WORK. D. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT, AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT DESCRIBED IN THE DOCUMENTS. E. CONTRACTOR SHALL INCLUDE IN THE BASE CONTRACT ALL PREMIUM TIME REQUIRED FOR SHUTDOWNS. F. THE FLOOR PLANS HAVE BEEN DEVELOPED UTILIZING EXISTING DOCUMENTS AND READILY OBSERVABLE SITE CONDITIONS. THE FLOOR PLANS MAY NOT SHOW EVERY EXISTING RECEPTACLE, LIGHT FIXTURE, SWITCH, CONDUIT, ETC. FIELD VERIFICATION OF ALL EXISTING DEVICES WILL BE REQUIRED TO BE MADE BY THE CONTRACTOR. EXISTING DEVICES WHICH ARE LOCATED ON EXISTING WALLS WHICH ARE TO BE DEMOLISHED OR IN THE PATH OF A NEW WALL SHALL BE REMOVED AND/OR RELOCATED AS REQUIRED. THE CONTRACTOR SHALL CONTACT THE ARCHITECT OR ENGINEER IF UNANTICIPATED FIELD CONDITIONS ARE ENCOUNTERED DURING CONSTRUCTION. NOTE THAT ELECTRICAL OR ELECTRONIC CIRCUIT TRACERS WERE NOT USED TO VERIFY THESE PLANS. CONTRACTOR SHALL FIELD VERIFY ALL SYSTEMS PRIOR TO COMMENCEMENT OF WORK. G. MAINTAIN AND RESTORE, IF INTERRUPTED BY DEMOLITION OR IN THE PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS AND FEEDERS PASSING THROUGH AND SERVING OUTSIDE OF DEMOLITION AREA. H. INVENTORY MAJOR ELECTRICAL ITEMS THAT ARE BEING REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION OF ITEMS TO BE RETAINED. ALL ITEMS NOT RETAINED BY,THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. I. EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS BEING REMOVED AND NOT REQUIRED FOR REUSE SHALL BE CUT OFF FLUSH WITH FLOOR. (E) MALL CORRIDOR (N.I.C) FR' L I F4 L I r _=_____� 7L / F� L L ==; / r Ir tx • • • • • • \ •\ • I L F#=== 1 I- I I- II • \ \ • \ J. ALL WIRING (BRANCH CIRCUIT, FEEDER, FIRE ALARM, ETC) THAT IS TO BE DEMOLISHED SHALL BE REMOVED COMPLETELY BACK TO SOURCE INCLUDING ALL CONDUIT, SUPPORTS, CONDUCTORS, ETC. DO NOT ABANDON ANY MATERIALS ABOVE CEILINGS OR IN WALLS. THE ASSOCIATED CIRCUIT BREAKERS SHALL BE TURNED OFF AND MARKED AS SPARE IF NOT REUSED FOR THE NEW CONSTRUCTION. UPDATE PANELBOARD DIRECTORIES AS REQUIRED. K. CONTRACTOR SHALL INCLUDE IN THEIR BID PRICE THE FIELD TRACING OF ALL FEEDERS AND BRANCH CIRCUITS ASSOCIATED WITH THE RENOVATION AREA TO VERIFY DEMOLITION AND REMOVAL OF SAME. AT A MINIMUM, THE CONTRACTOR SHALL UTILIZE ELECTRONIC CIRCUIT TRACERS TO AID IN THE TRACING OF CIRCUITS. THE CONTRACTOR SHALL DOCUMENT ALL FINDINGS, NOTING CONFLICTS AND DISCREPANCIES WITH CONSTRUCTION DOCUMENTS. FINDINGS SHALL BE SUBMITTED AS A SHOP DRAWING TO THE ENGINEER FOR REVIEW. L. MAINTAIN AND RESTORE IF INTERRUPTED BY REMOVALS OR IN THE PATH OF NEW CONSTRUCTION ALL CIRCUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS SHOWN OR NOT SHOWN. M. IN ANY AREA REQUIRING THE PERFORMANCE OR ANY TRADES WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE AND RESTORE ANY OR ALL ELECTRICAL ITEMS IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADES WORK IN THAT AREA. N. IN ALL EXISTING OR NEW AREAS SPECIFIED OR SHOWN TO BE PAINTED, THIS CONTRACTOR SHALL REMOVE ALL ELECTRICAL ITEMS AS REQUIRED INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, DEVICE PLATES, DEVICES, ETC. REINSTALL SAME AFTER COMPLETION OF PAINTING. ANY ITEM NOT REMOVED AND PAINTED OVER SHALL BE SUITABLY CLEANED OR REPLACED WITH A NEW ITEM BY THIS CONTRACTOR. 0. EXISTING FLUSH OUTLET BOXES MAY BE REUSED IF AT PROPER HEIGHT, LOCATION, AND IN GOOD CONDITION. EXISTING CONCEALED RACEWAYS MAY BE REUSED IF IN GOOD CONDITION, RACEWAYS FOR CIRCUITRY SHOWN ON PLANS SHALL GOVERN. / trt r-----L.L r -- I E L J 11 7 7 I II II 1 l J L (E) ADJACENT TENANT (N.I.C) 'I ELECTRICAL DEMOLITION PLAN E100 SCALE: 114" =1'-0" ! I 6== I I I I 1 1 1 i __J I ! 1 L L kT --____ / // t , I r i 11 I 11 I I 1 1 1 J 1 ---J r TT----rT I I 1 I 11 1 1 I L----� 1 I I -r----•-7T 1 1 I I 11 I I 1 L---- 1 11 _f'I__,...... T T 1 1 11 11 __ 1 1 I I 11 7 1 j LJ I I I r—__ 11 I 111 I 1 1 I - _ t 125A ODISCONNECT SWITCH (ETR) (::)PANEL HP (ETR) •\ • ===___ `s 9 r�� I1 45kVA TRANSFORMER (REX)() PANEL LP (REX) PANEL PP (REX) —r' -, GENERAL SHEET NOTES A. PRIOR TO ANY EXECUTION OF WORK, THE CONTRACTOR SHALL MEET WITH THE OWNER/ARCHITECT TO DISCUSS SCOPE OF DEMOLITION WORK. B. PRIOR TO ANY ISOLATION OF SYSTEMS, SHUTDOWNS, OR DEMOLITION THE CONTRACTOR SHALL PROVIDE NECESSARY INVESTIGATION AND NOTIFY THE FACILITIES ENGINEERING/MAINTENANCE PERSONNEL OF WORK TO BE PERFORMED SO AS TO AVOID ANY DETRIMENTAL SHUTDOWN OF SYSTEMS TO ADJACENT SPACES. C. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING SAFETY BY DISCONNECTING, CUTTING, AND MAKING SAFE ALL DEMOLITION WORK. D. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT, AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT DESCRIBED IN THE DOCUMENTS. E. CONTRACTOR SHALL INCLUDE IN THE BASE CONTRACT ALL PREMIUM TIME REQUIRED FOR SHUTDOWNS. F. THE FLOOR PLANS HAVE BEEN DEVELOPED UTILIZING EXISTING DOCUMENTS AND READILY OBSERVABLE SITE CONDITIONS. THE FLOOR PLANS MAY NOT SHOW EVERY EXISTING RECEPTACLE, LIGHT FIXTURE, SWITCH, CONDUIT, ETC. FIELD VERIFICATION OF ALL EXISTING DEVICES WILL BE REQUIRED TO BE MADE BY THE CONTRACTOR. EXISTING DEVICES WHICH ARE LOCATED ON EXISTING WALLS WHICH ARE TO BE DEMOLISHED OR IN THE PATH OF A NEW WALL SHALL BE REMOVED AND/OR RELOCATED AS REQUIRED. THE CONTRACTOR SHALL CONTACT THE ARCHITECT OR ENGINEER IF UNANTICIPATED FIELD CONDITIONS ARE ENCOUNTERED DURING CONSTRUCTION. NOTE THAT ELECTRICAL OR ELECTRONIC CIRCUIT TRACERS WERE NOT USED TO VERIFY THESE PLANS. CONTRACTOR SHALL FIELD VERIFY ALL SYSTEMS PRIOR TO COMMENCEMENT OF WORK. G. MAINTAIN AND RESTORE, IF INTERRUPTED BY DEMOLITION OR IN THE PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS AND FEEDERS PASSING THROUGH AND SERVING OUTSIDE OF DEMOLITION AREA. H. INVENTORY MAJOR ELECTRICAL ITEMS THAT ARE BEING REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION OF ITEMS TO BE RETAINED. ALL ITEMS NOT RETAINED BY,THE OWNER SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. I. EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS BEING REMOVED AND NOT REQUIRED FOR REUSE SHALL BE CUT OFF FLUSH WITH FLOOR. (E) MALL CORRIDOR (N.I.C) FR' L I F4 L I r _=_____� 7L / F� L L ==; / r Ir tx • • • • • • \ •\ • I L F#=== 1 I- I I- II • \ \ • \ J. ALL WIRING (BRANCH CIRCUIT, FEEDER, FIRE ALARM, ETC) THAT IS TO BE DEMOLISHED SHALL BE REMOVED COMPLETELY BACK TO SOURCE INCLUDING ALL CONDUIT, SUPPORTS, CONDUCTORS, ETC. DO NOT ABANDON ANY MATERIALS ABOVE CEILINGS OR IN WALLS. THE ASSOCIATED CIRCUIT BREAKERS SHALL BE TURNED OFF AND MARKED AS SPARE IF NOT REUSED FOR THE NEW CONSTRUCTION. UPDATE PANELBOARD DIRECTORIES AS REQUIRED. K. CONTRACTOR SHALL INCLUDE IN THEIR BID PRICE THE FIELD TRACING OF ALL FEEDERS AND BRANCH CIRCUITS ASSOCIATED WITH THE RENOVATION AREA TO VERIFY DEMOLITION AND REMOVAL OF SAME. AT A MINIMUM, THE CONTRACTOR SHALL UTILIZE ELECTRONIC CIRCUIT TRACERS TO AID IN THE TRACING OF CIRCUITS. THE CONTRACTOR SHALL DOCUMENT ALL FINDINGS, NOTING CONFLICTS AND DISCREPANCIES WITH CONSTRUCTION DOCUMENTS. FINDINGS SHALL BE SUBMITTED AS A SHOP DRAWING TO THE ENGINEER FOR REVIEW. L. MAINTAIN AND RESTORE IF INTERRUPTED BY REMOVALS OR IN THE PATH OF NEW CONSTRUCTION ALL CIRCUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS SHOWN OR NOT SHOWN. M. IN ANY AREA REQUIRING THE PERFORMANCE OR ANY TRADES WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE AND RESTORE ANY OR ALL ELECTRICAL ITEMS IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADES WORK IN THAT AREA. N. IN ALL EXISTING OR NEW AREAS SPECIFIED OR SHOWN TO BE PAINTED, THIS CONTRACTOR SHALL REMOVE ALL ELECTRICAL ITEMS AS REQUIRED INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, DEVICE PLATES, DEVICES, ETC. REINSTALL SAME AFTER COMPLETION OF PAINTING. ANY ITEM NOT REMOVED AND PAINTED OVER SHALL BE SUITABLY CLEANED OR REPLACED WITH A NEW ITEM BY THIS CONTRACTOR. 0. EXISTING FLUSH OUTLET BOXES MAY BE REUSED IF AT PROPER HEIGHT, LOCATION, AND IN GOOD CONDITION. EXISTING CONCEALED RACEWAYS MAY BE REUSED IF IN GOOD CONDITION, RACEWAYS FOR CIRCUITRY SHOWN ON PLANS SHALL GOVERN. / trt r-----L.L r -- I E L J 11 7 7 I II II 1 l J L (E) ADJACENT TENANT (N.I.C) 'I ELECTRICAL DEMOLITION PLAN E100 SCALE: 114" =1'-0" E— --D L -----_—J 1 r------1 1 I1 11 I1 11 11 11 JJ_..........._ --L1 -i- 0 SHEET KEYNOTES I r----1 I II II 11 II I 1 I I 1 J _ _ _ _ 1 1 1 REMOVE ALL EXISTING TENANT ELECTRICAL EQUIPMENT, LIGHT FIXTURES, JUNCTION BOXES, RECEPTACLES, SWITCHES, ETC. WITHIN THIS AREA UNLESS OTHERWISE NOTED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE AS REQUIRED. REFER TO ARCHITECTURAL PLANS FOR ADDITIONAL DEMOLITION INFORMATION. 2 EXISTING ELECTRICAL EQUIPMENT TO REMAIN. PROTECT AND MAINTAIN ALL ASSOCIATED CONDUIT AND WIRING AS REQUIRED. 3 EXISTING ELECTRICAL EQUIPMENT TO BE REMOVED. REMOVE ALL ASSOCIATED CONDUIT AND WIRING BACK TO SOURCE. r ❑ 1I ! I / r r1 I I J r— 1 1 1 / i❑ L� / c / • • • \ • • • • ,_ / 1 ' 9 1 ti _J t r1 1/ r/ REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC APR 12 MB City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER 3292 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT O RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 E PROJECT NAME W Z ‘ 0161 Cl. � —.1°7; M-ZtIC:t1 02 Q W U W� 0 11? W O z SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME ELECTRICAL DEMOLITION PLAN DWN BY: EFO CHK BY: EJR SHEET NUMBER E100 SCALE: 1/4" = 1'-O" L-5 EM1 LS2 L-5 LS2 L-5 LS2 L-5 5 LS2 EMI L-5 QC LS2 L-5 LS2 I i L-5 L-5 LS2 L-5 LS2 L-5 LS2 1 1 L-5 J8 SALES AREA 4 HOME / LIFESTYLE & STATIONERY AREA L-5 d EM1 SALES AREA 3 FRIDGE ZONE L-9 STOCK LPI *L-3 TT1-17'-0" EK--> -10 T -t L-10 L-10 LT2 L-1 L-10 LP1 L11 0 L-10 LT1 1 (E) ADJACENT TENANT (N.I.C) SALES AREA 2 SELFIE ZONE LT2 LTT1LTTI Tilt 292'-" T T L-4 L-4 1> L-4 L-4 03E L-4 Q 9E LP1 •L-3 TTI -29'-7" L-4 L-4 LT2 L-4 -4 0 Lit L L-4 0 J (-� L-4 L-4 O TTI -29'-7" L-4 J F� L-4 L-40-> L-4 O 3 4 LT2 L-4 L-4 L-4 Lj2 L-4 � � L-4 Ill L-4 SALES AREA 1 SKIN CARE / K -BEAUTY t1-4QL-4 J LI: L-4 611 L-4 L-6 LT1 \E2 L-42 L-4 LT2 DISPLAY 1 L-4 L-4 O _ F33-rl LT2 L 4 L-4 -1- L-4 L-4 TTI -16'-3" L,1 LTEIP1 EM 0 L-42 L-42 E2 LI2 L -4Q L-4 LSI DPI DPI DPI DPI DPI 10 TT1-10'-10" L-11 0 DPI DPI DPI DP1 DPI (E) MALL CORRIDOR (N.I.C) GENERAL SHEET NOTES A. ALL 120V BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. B. ELECTRICAL CONTRACTOR TO REFER TO ARCHITECTURAL DRAWINGS FOR ALL LIGHT FIXTURE LOCATIONS. C. ALL BRANCH CIRCUIT WIRING SHALL BE #12 AWG UNLESS OTHERWISE NOTED. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. EXIT/EMERGENCY LIGHTING NOTES A. EVERY DOORWAY LEADING TO THE MALL OR AN EXIT CORRIDOR MUST BE EQUIPPED WITH EMERGENCY BATTERY PACK EXIT LIGHTS. B. IN ADDITION TO THE EXIT IDENTIFICATION LIGHTS, SPACE MUST BE EQUIPPED WITH EMERGENCY ILLUMINATION. ALL EMERGENCY LIGHTS MUST BE UL APPROVED AND HAVE A CONVENIENCE TEST FEATURE. DURATION AND LIGHT LEVELS TO BE SPECIFIED BY FIRE AND BUILDING CODES. C. WIRE ALL NIGHT LIGHTING, EXIT SIGNS, EMERGENCY FIXTURES AHEAD OF LOCAL SWITCHING, UNLESS OTHERWISE NOTED. D. ALL EXIT SIGNS AND EGRESS FIXTURES LOCATED IN OPEN CEILING AREAS SHALL BE MOUNTED AT 11'-00" AFF. REFER TO ARCHITECTURAL PLANS FOR FIXTURE SUPPORT DETAILS. SALES AREA 5 TOOLS / TRAVEL & TECH. SALES AREA 6 CANDY ZONE (E) ADJACENT TENANT (N.I.C) 1 LIGHTING PLAN (40 WO SCALE: 114"=1'-0" CASHWRAP SALES AREA 7 ISLAND ; COLOR / BEST SELLERS 0 SHEET KEYNOTES 1 ALL SALES FLOOR LIGHT FIXTURES LABELED "EM" SHALL BE WIRED TO THE EMERGENCY INVERTER, REFER TO WIRING DIAGRAM ON SHEET E600. ALL "EM" FIXTURES MUST TURN OFF AFTER HOURS, NO NIGHT LIGHTS ARE PERMITTED WITHIN THE SPACE. 2 PROVIDE 2 -BUTTON CONTROLLER FOR MANUAL ON/OFF CONTROL OF AREA FIXTURES. REFER TO LIGHTING CONTROL DETAILS ON SHEET E601 FOR SPECIFICATION. 3 LOCATION OF ZONE SWITCH W/ OVERRIDE REFER TO DETAIL ON SHEET E600 FOR ADDITIONAL INFORMATION. PROVIDE LOCKABLE ENCLOSURE. 4 PROVIDE OCCUPANCY SENSOR FOR LOCAL ON/OFF CONTROL OF AREA FIXTURES. REFER TO LIGHTING CONTROL DIAGRAM ON SHEET E600 FOR SPECIFICATION. 5 EXISTING LANDLORD COMMON AREA AND EMERGENCY EGRESS LIGHTING SHALL REMAIN. 6 PROVIDE STAND-ALONE WALL OCCUPANCY SWITCH FOR AUTOMATIC AND MANUAL ON/OFF CONTROL OF AREA FIXTURES. REFER TO LIGHTING CONTROL DETAIL ON SHEET E601 FOR SPECIFICATION. ENTRY DISPLAY 1 REVIEWED .FOR COMPLIANCE WITH NFPA70-NEC APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER 01 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER F/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 PROJECT NAME: z O 3- w U z w 0 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME LIGHTING PLAN DWN BY: EFO CHK BY: EJR SHEET NUMBER E110 SCALE: 1/4" = I'-0" FAEP R-55 1 125A DISCONNECT SWITCH (ETR) L R-2 GFI WP CaR-29 PANEL R 75kVA - LCP/CLP INVERTER L-40 111 R-29 R-35 RESTROO SALES AREA 5 HOME / LIFESTYLE & STATIONERY AREA SALES AREA 4 DANIELLE L-22 SALES AREA 3 SELFIE ZONE L-22 (E) ADJACENT TENANT (NAL) 1 14" SALES AREA 2 SKIN CARE SALES AREA 1 COLOR R-13 R-13 14" 14" R-13 R-13 14" 14" R-15 R-15 14" 14" R-15 14" R-15 14" IU R3 0 R-17 90" R-17 90" R-17 .. 1."..IIN 90" R-17 90" R-17 66" R-17 90" R-17 90" R-19 LR -19 90" 90" R-19 66" R-19 90" R-19 90" / CC J R- 5 w o z oz 2= n........- -- / \ \ R-7 \ w 0 - e — -A®E-M=P (ETR)®MIM R-36 ®®_a. . R-36 R-38 R-40 R-28 R-34 44" 44" 44' STOCK HA AY R - R- HOME ENDCAP (E) MALL CORRIDOR (N.I.C) 0 TELEPHONE BOARD EQUIPMENT 1 PLYWOOD BACKBOARD: 2 TOTAL, 4' X 8' X 3/4". MOUNT ON WALL AS INDICATED. 2 BURGLAR ALARM PANEL: 1 QUAD OUTLET W/ DEDICATED 120V CIRCUIT. 3 AV RACK/SHELF: 1 QUAD OUTLET W/ DEDICATED 120V CIRCUIT FOR AV RACK AND MUSIC PLAYER. 4 SERVER RACK: 2 QUAD OUTLETS W/ DEDICATED 120V CIRCUITS FOR IT SERVER RACK AND DVR EQUIPMENT. 2 -GANG BOX: PROVIDE 2-3/4" CONDUITS TO SALES AREA FOR TERMINATION OF SOUND SYSTEM WIRE AND TERMINATION OF CAT5 CABLE FOR VOLUME CONTROL. VERIFY EXACT LOCATION OF CONDUIT STUB IN SALES AREA WITH ARCHITECT. 2 oz E2.1.0 SCALE: NONE 1 I- 1 R -5 Q HOME ENDCAP (E) MALL CORRIDOR (N.I.C) 0 TELEPHONE BOARD EQUIPMENT 1 PLYWOOD BACKBOARD: 2 TOTAL, 4' X 8' X 3/4". MOUNT ON WALL AS INDICATED. 2 BURGLAR ALARM PANEL: 1 QUAD OUTLET W/ DEDICATED 120V CIRCUIT. 3 AV RACK/SHELF: 1 QUAD OUTLET W/ DEDICATED 120V CIRCUIT FOR AV RACK AND MUSIC PLAYER. 4 SERVER RACK: 2 QUAD OUTLETS W/ DEDICATED 120V CIRCUITS FOR IT SERVER RACK AND DVR EQUIPMENT. 2 -GANG BOX: PROVIDE 2-3/4" CONDUITS TO SALES AREA FOR TERMINATION OF SOUND SYSTEM WIRE AND TERMINATION OF CAT5 CABLE FOR VOLUME CONTROL. VERIFY EXACT LOCATION OF CONDUIT STUB IN SALES AREA WITH ARCHITECT. 2 TELEPHONE BACKBOARD ELEVATION E2.1.0 SCALE: NONE tc R-3 F • • • • R-56 0 O co 1 m c 1 z0 POWER PLAN0 --� m R-11 C 0 1 VAV-1 0 c z 0 POWER PLAN0 11 E210 z _m� � 33N1:100 VIOCNOD 00 oO cz a'O 31 V10 z 0 0 1 0 0 0z w J m 0 0 AHU-2 noa 3 NO`3 Vl R-5 P OR -9 / /0/ r R-26 1/11 j--1 60" DISPLAY 1 -14 noa MOD 4111111111111111111111111111111111.1 38111c1 3SlndVH c TOWER R-11 3lONIS 31E NIS I. VIO0NOO VlOaNOS 111111111111111111111111 amilam.IITnT 3Slf1d1A11 3SlndW1 Qw ©m o� z 00 GONDOLA CORNER 0 0 c w 1- m R-9 R-9 3 `:: R-9 I L R-9 R-42 18 R-25 R-25 90" 90" L-24 R-25 R-25 90" 90" G) 0 z 0 0 w -J 0 0 R-27 66" "v o (TYP) R-27 90" -R-27 R-27 R-27 R-27 90" ! 90" 90" 66° R-27 90" R-27 / 90" / R-3 (TYP) R-26 60" DISPLAY GENERAL SHEET NOTES R-21 R-21 R-4 14" SALES AREA 6 HAIR ! TECH. OCAMMIROVANkie 14" 15" L-24 R-6 - R-14 I- L-19 --R-6 R-16 80" R-21 14" R-21 14" R-23' 14"" SALES AREA 7 A DY ZONE CASH P (E) ADJACENT TENANT (N.I.C) 1 POWER PLAN0 E210 SCALE: 114"=1'-0" A. ALL 120V BRANCH CIRCUITS IN EXCESS OF 75' SHALL HAVE CONDUCTOR SIZE INCREASED A MINIMUM OF 1 CONDUCTOR SIZE. INSTALLING CONTRACTOR SHALL DETERMINE ACTUAL CONDUCTOR SIZE TO BE INSTALLED TO ADHERE TO VOLTAGE DROP REQUIREMENTS. B. ALL BRANCH CIRCUIT WIRING SHALL BE #12 AWG UNLESS OTHERWISE NOTED AND IN CONDUIT/EMT. EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL CONDUCTOR. C. SHOW WINDOW RECEPTACLE COVERPLATE COLOR SHALL MATCH ADJACENT CEILING COLOR. D. LOCATION OF FLOOR MOUNTED OUTLETS TO BE COORDINATED WITH ARCHITECTURAL POWER PLANS AND FIXTURE CONTRACTOR. COORDINATE EXACT REQUIREMENTS. E. NO BX, AC, OR ROMEX WIRING IS ALLOWED. F. REFER TO SHEET E310 FOR ALL LOW VOLTAGE AND SECURITY REQUIREMENTS. G. ALL FIRE ALARM DEVICES LOCATED IN OPEN CEILING AREAS SHALL BE MOUNTED AT XX' -X" AFF. H. REFER TO SHEET E211 FOR POWER/DATA DISPLAY DIMENSIONS. ( SHEET KEYNOTES 1 PROVIDE 120V POWER, JUNCTION BOX, WHIP, AND TOGGLE SWITCH FOR INTERIOR/EXTERIOR SIGNAGE. COORDINATE EXACT LOCATION AND ALL REQUIREMENTS WITH SIGN VENDOR. SIGN CIRCUIT SHALL BE WIRED THROUGH LIGHTING CONTROL PANEL. 2 RECEPTACLE SHALL BE MOUNTED HORIZONTALLY AND INSTALLED AT 15"AFF. EC SHALL VERIFY EXACT LOCATION WITH ARCHITECT. TYPICAL FOR ALL COUMN MOUNTED RECEPTACLES. 3 PROVIDE DEDICATED 120V POWER AND QUAD RECEPTACLE FOR POWER TO EAS SYSTEM. RECEPTACLE SHALL BE LOCATED WITH 12" OF ACCESS HATCH, COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE 3/4"C FROM SYSTEM ANTENNAS TO CEILING ACCESS HATCH, REFER TO PLANS FOR QUANTITY AND LOCATIONS. MAXIMUM DISTANCE FROM ANTENNA TO ACCESS HATCH SHALL BE 20'. 4 PROVIDE SHOW WINDOW RECEPTACLE PER NEC REQUIREMENTS. RECEPTACLE SHALL BE INSTALLED WITHIN 18° OF THE TOP OF THE SHOW WINDOW FOR EACH 12' OF SHOW WINDOW. VERIFY EXACT LOCATION WITH ARCHITECT. 5 LOCATION OF ELECTRICAL EQUIPMENT, REFER TO ONE LINE ON SHEET E600 FOR ADDITIONAL INFORMATION. PROVIDE ALL REQUIRED CLEARANCES PER NATIONAL ELECTRICAL CODE. 6 LOCATION OF LIGHTING CONTROL AND CURRENT LIMITING PANEL, REFER TO SHEET E601 FOR ADDITIONAL INFORMATION. 7 PROVIDE (2) 4'x 8'x 3/4" PLYWOOD BACKBOARDS FOR TELEPHONE/DATA/SECURITY EQUIPMENT. REFER TO DETAIL ON SHEET THIS SHEET FOR ADDITIONAL INFORMATION. 8 PROVIDE 120V POWER TO HAND DRYER AT 34"AFF. HAND DRYER PROVIDED/INSTALLED BY OTHERS, REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION. 9 PROVIDE 120 POWER FOR WATER FOUNTAIN. RECEPTACLE SHALL BE SUB -FED FROM NEAREST GFI PROTECTED RECEPTACLE. 10 ISOLITE 250W MINI INVERTER. COORDINATE EXACT LOCATION WITH ARCHITECT. 11 PROVIDE 2 -GANG SURFACE MOUNTED FLOOR BOX AT DISPLAY: HUBBELL B4214 WITH 1-SA3625 COVERPLATE, 1-SA2625 COVERPLATE, AND 1-SA3084 2 -GANG FLANGE. PROVIDE DUPLEX RECEPTACLE IN FLOOR BOX. R-23 14" R-23 R-23 14" 14° SALES AREA 8 SLAND ( COLOR / BEST SELLERS R-23 14" R-23 14" 12 FLOOR BOX POWER: TRENCH FLOOR AND ROUTE 1-3/4°C WITH POWER CABLING TO FLOOR BOX. ROUTE CONDUIT UP THROUGH WALL OR COLUMN TO DESTINATION INDICATED. MAKE ALL FINAL CONNECTIONS. COORDINATE WITH ARCHITECT, TENANT COORDINATOR, AND ANY OTHER REQUIRED PARTIES PRIOR TO WORK. 13 PROVIDE SURFACE MOUNTED. JUNCTION BOX AT CASHWRAP: HUBBELL-RACO 674 HANDY BOX (2" x 4" x 2 1/8"). PROVIDE DUPLEX RECEPTACLE IN FLOOR BOX. 14 CASHWRAP POWER: TRENCH FLOOR AND ROUTE 2-3/4"C (1 FOR GENERAL POWER AND 1 FOR DEDICATED POWER) WITH POWER CABLING TO SURFACE MOUNTED JUNCTION BOX. ROUTE CONDUIT UP THROUGH WALL OR COLUMN TO DESTINATION INDICATED. PROVIDE FLEXIBLE CONNECTION AND DUPLEX RECEPTACLES IN CASHWRAP FIXTURE AND MAKE ALL FINAL CONNECTIONS. VERIFY LOCATIONS OF JUNCTION BOX AND DEVICES WITH FIXTURE SHOP DRAWINGS AND ACCESS PANEL LOCATIONS. CONDUIT SHALL BE RUN IN COMMON TRENCH WITH CASHWRAP DATA CONDUIT. COORDINATE WITH ARCHITECT, TENANT COORDINATOR, AND ANY OTHER REQUIRED PARTIES PRIOR TO WORK. 15 KITCHEN ISLAND POWER: TRENCH FLOOR AND ROUTE 1-3/4"C WITH POWER CABLING TO SURFACE MOUNTED JUNCTION BOX. ROUTE CONDUIT UP THROUGH WALL OR COLUMN TO DESTINATION INDICATED. PROVIDE FLEXIBLE CONNECTION AND DUPLEX RECEPTACLES IN ISLAND FIXTURE AND MAKE ALL FINAL CONNECTIONS. VERIFY LOCATIONS OF JUNCTION BOX AND DEVICES WITH FIXTURE SHOP DRAWINGS AND ACCESS PANEL LOCATIONS. CONDUIT SHALL BE RUN IN COMMON TRENCH WITH KITCHEN ISLAND DATA CONDUIT. COORDINATE WITH ARCHITECT, TENANT COORDINATOR, AND ANY OTHER REQUIRED PARTIES PRIOR TO WORK. 16 MECHANICAL/PLUMBING EQUIPMENT. REFER TO SCHEDULE ON SHEET E600 FOR CIRCUITING/CONNECTION INFORMATION. 17 PROVIDE 1 -DUPLEX RECEPTACLE AT 90"AFF FOR LED SCREEN. COORDINATE EXACT LOCATION WITH ARCHITECT. 18 TRAFFIC COUNTER: INSIDE ACCESS HATCH (24"X24") WITHIN 1FT. QUAD OUTLET, 120V -1q -3W, DEDICATED CIRCUIT. ALSO A 4'X2' BACKER BOARD SHALL BE PROVIDED FOR MOUNTING EQUIPMENT. IF CEILINGS ARE HIGHER THAN THE 13', THE ACCESS HATCH CAN BE PLACED ON COLUMN ACCESSED NEAR FLOOR IF THERE IS AT LEAST 8" OF DEPTH AND SPACE FOR CONTROLLER AND CAP BOARD ENCLOSURE. EC SHALL PROVIDE (2) 3/4" RGC FROM ANTENNAS TO CEILING ACCESS HATCH. MAXIMUM DISTANCE SHALL BE 20FT FOR BETTER PERFORMANCE. EC SHALL PROVIDE (1) CAT5E CABLE FROM EACH TRAFFIC COUNTER /RFID HOMERUN BACK TO NETWORK SWITCH IN STOCK ROOM, AND (3) CAT5E CABLES FROM EACH ACCESS PANEL HOMERUN BACK TO NETWORK SWITCH IN STOCK ROOM WITH 25' SLACK COILED UP AT THE ACCESS PANEL END. 19 PROVIDE JUNCTION BOX AND 120V POWER FOR EXIT ALARM SYSTEM (DETEX EAX-2500SK1). PROVIDE ALL REQUIRED WIRING AND HARDWARE FOR A COMPLETE INSTALLATION. VERIFY EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN. RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA70 o NEC APR 12 2018 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER /S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 R PROJECT N w ci) co J <cc' o � Q z Y � U = H O 15W SSUANCE DESCRIPTION 0 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME POWER PLAN DWN BY: EFO CHK BY: EJR SHEET NUMBER E210 SCALE: 1/4" = 1'-0" RESTROO SALES AREA 5 HOME / LIFESTYLE & STATIONERY AREA SALES AREA 4 DANIELLE tvanftw000amotmox SALES AREA 3 SELFIE ZONE (E) ADJACENT TENANT (NIC) SALES AREA 2 SKIN CARE SALES AREA 1 COLOR 1 S GENERAL SHEET NOTES STOCK HA WAY 1 (E) MALL CORRIDOR (N.I.C) A. FLOOR BOX LOCATIONS AND DIMENSIONS SHALL BE VERIFIED WITH ARCHITECTURAL PLANS PRIOR TO ROUGH -IN. 8'-2" 10' w Oz S= 0 HOME w 0z Z ENDCAP 0 8'-4" low TOWER 10' 1 • VlOONOE DOUBLE 7ONDOLA Bienoa 7'-7" 0 0 c I I 0 Cl z O 0 z 0 0 0 0 C = zo m w� pz C m zo KS E211 ..I m Lu . Oz HOME ENDCAP 10' 1 • VlOONOE DOUBLE 7ONDOLA Bienoa 7'-7" 0 0 c I I 0 Cl z O 0 z 0 0 0 0 C = zo m FLOOR BOX DIMENSION PLAN C m zo KS E211 ..I m C_ z0 --I m FLOOR BOX DIMENSION PLAN c1 z � E211 --1 WI 213N*IOo VloaNOS 00 00 cz „O D 2'-2 3/4" 6'-3" 0 c co m Bl8noa Blanoa V1OONO0 V100NO0 Ailmisomm Mmionwitomm 3 Slndwl BSIndWI c r 11 U) 1 7'-1" 0 co r rn 0 0 z o 0 0) O 0 z 0 O -J 0 0 6'-10" DISPLAY TABLE -J BISNIS MONIS 2 VlOONOS V1O0NO0 BSIndWI BSIndWI 0m �J z0 Op t7 GONDOLA CORNER 3MO1I3MOl JL J SALES AREA 6 HAIR / TECH. SA C ES AREA 7 DY ZONE ao.tmArkft.~ Ar" CASHWRAP 0 0 c CO r m z O O O 0 z 0 r J 0 p (E) ADJACENT TENANT (N.I.C) 1 FLOOR BOX DIMENSION PLAN 0 E211 SCALE: 114"=1'-0" 0 0 c co r m O 0 z 0 p z O O J 7'-3 1/,2" 0 r 0 / • • • TOWEFTOWL R 15'-9" TOWER 7'-10" • 1 • • DISPLAY 1 1 7'-10" 0 c D7 r- 111 m 0 c z O 0 0 z L.1 D 0 .•••••••••••••••V 111111..**&••••••••11111 ( o, ISLAND 7'-10" TOWER 7'-10" of 1 T-" 0 SALES AREA 8 COLOR / BEST SELLERS ENTRY DISPLAY 1 REVIEWED FOR COMPLIANCE WITH NFPA700NEC APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 PROJECT NAME: w U a_ co (/) 00 co Q Q I- J Z w� U D F- 1- 0 (/) (0 SSUANCE DESCRIPTION w Q 0 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME FLOOR BOX DIMENSION PLAN DWN BY: EFO CHK BY: EJR SHEET NUMBER E211 SCALE: 1/4" = 1'-0" RESTROOM SALES AREA 5 HOME / LIFESTYLE & STATIONERY AREA SALES AREA 4 DANIELLE SALES AREA 3 SELFIE ZONE (E) ADJACENT TENANT (N.I.C) SALES AREA 2 SKIN CARE SALES AREA 1 COLOR 0) 0 CD CD co co co 00 0) 0 x_ 0) r I -55 AO rW mF -t- r / WAP 01 T- r kr—l� X 01 0 4 f i 0 STOCK HALL WAY L_. (E) MALL CORRIDOR (N.I.C) DATA/SECURITY DEVICE MATRIX DEVICE GROUP LABEL PROVIDED BY INSTALLED BY WIRED BY CABLE TYPE # OF CABLES # OF SPARE DESTINATION FIXED CAMERA DVR OWNER VENDOR OWNER VENDOR EC 1-RG59 COAX 1-18/2 1-CAT5e 1 OF EACH TYPE 1 OF EACH TYPE DATA RACK WIRELESS ACCESS POINT WAP OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK CASHWRAP STATION C OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK BACKWRAP STATION B OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK DOOR CONTACT DC OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK MOTION SENSOR MS OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK KEYPAD KP OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK MANAGER'S DESK X OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK LED SCREEN LED OWNER VENDOR OWNER VENDOR EC CAT5e 1 1 DATA RACK NOTES: 1. REFER TO PLANS FOR # AND TYPES OF DEVICES. 2. COORDINATE ALL LOCATIONS WITH VENDOR SHOP DRAWINGS. * CONFIRM # OF CABLES TO EACH DEVICE WITH VENDOR PRIOR TO INSTALLATION. '' � �` WAP 02 \\ 1 i WAP ' r f t LED 4 / LED 02 LED 01 DC 01 DC 0 DVR-09 DVR-11 D0 DVR-01 %� WAP 03 �\`y LED 34 LED 33 11 11 LED 30 I 1 1= C-02 LED 04 LED 05 C-03 LED 06 LED 07 LED 29 LED 28 DVR-07 LED 08 LED 09 LED 10 LED 11 DVR-08 011104 0 0 0 0 , S111110 %NO DVR-03 LED 27 66"LED 26 LED 25 LED 2 LED 23 LED 12 LED 13 66" DVR-06 I) OQ DVR-05 `. /WAP 04 ',� / r i WAP ' t t ------ LED 22 66" MEE LED 21 LED 14 LED 15 ! r ! L !r !L� Ir ! I r- - -.17 ! 60 1811 " LED 20 J ! ! ! ! DISPLAY / / LED 17 1/ i-1- 60" /n/ 1 f1/1)1 11 11 ENTRY In ru 1 1 LED 19 60" DISPLAY 1 LED 31 —DVR-02 (TYP) SALES AREA 6 HAIR / TECH. SALES AREA 7 CANDY ZONE CASHWRAP (E) ADJACENT TENANT (N.I.C) ISLAND SALES AREA 8 COLOR / BEST SELLERS 1 LOW VOLTAGE PLAN1:3 E310 SCALE: 1I4"=1'-0" GENERAL SHEET NOTES 1. REFER TO DATA/SECURITY DEVICE MATRIX FOR ALL REQUIREMENTS AND RESPONSIBILITIES. 2. ALL CABLES MUST BE PLENUM RATED. 3. ALL CABLES MUST BE HOMERUNS FROM EACH DEVICE TO THE DATA RACK. CABLES MUST BE LABELED AT EACH END AND AT 3' FROM EACH END. LABELS AT EACH END OF CABLES SHALL MATCH. PROVIDE 100% CONTINUITY CHECK FOR ALL DATA CABLES. 4. FOR LOW VOLTAGE/CAT5E CABLES, PROVIDE 10' OF COILED CABLE AT EACH END FOR FUTURE USE AND MOVEMENT. 5. FOR CCTV/WAP CABLES, PROVIDE 30' OF COILED CABLE AT EACH END FOR FUTURE USE AND MOVEMENT. 6. PROVIDE 1 -SPARE CAT5e CABLE WITH ALL CABLE RUNS UNLESS OTHERWISE NOTED. 7. ALL CABLING MUST BE PULLED PRIOR TO OWNER VENDOR'S ARRIVAL. FINAL TERMINATION OF ALL CABLES TO BE COMPLETED BY OWNER'S VENDOR. 8. COORDINATE EXACT LOCATION OF ALL DEVICES WITH OWNER'S VENDOR. 9. AUDIO EQUIPMENT RACK IS TO BE MOUNTED AT 7' AFF IN STOCK ROOM ACCORDING TO MANUFACTURER'S INSTALLATION MANUAL AND ALL APPLICABLE LOCAL CODES. EC TO PROVIDE 2 -GANG BOX WITH (2) 3/4°C STUBBED INTO SALES AREA. EC TO PROVIDE (1) 20A QUAD OUTLET (UON) WITH DEDICATED CIRCUIT ADJACENT TO AUDIO EQUIPMENT J -BOX. 10. SHELF FOR MUSIC PLAYER IS TO BE WALL MOUNTED DIRECTLY UNDER AUDIO EQUIPMENT RACK. SEE SPEAKER INSTALLATION DRAWINGS. 11. VOLUME CONTROLS TO BE MOUNTED AT LIGHT SWITCH HEIGHT BESIDE STOCK ROOM DOOR NEAREST SALES AREA. EC TO PROVIDE (1) 5 -GANG BOX (FOR CC -64 ONLY) WITH 3/4"C TO AUDIO EQUIPMENT RACK J -BOX. 12. GC/EC RESPONSIBLE FOR PROVIDING AND INSTALLING RACK BACKER BOARD, ELECTRICAL OUTLETS, AND ALL CONDUIT. 13. ALL. EXPOSED CABLE/CONNECTORS SHALL BE WHITE AND INCONSPICUOUS. THERE SHOULD BE NO VISIBLE CABLES. 14. VERIFY DJ WALL PLATE LOCATION WITH PROJECT MANAGER PRIOR TO PRE -WIRE AND INSTALLATION. 0 SHEET KEYNOTES REVI WED F()h SNFP 70 MP IANC� ENEC INITFE APR 12 2018 City of•Tulzwila BUILDING DIVISION 1 PROVIDE SURFACE MOUNTED JUNCTION BOX AT CASHWRAP: HUBBELL-RACO 674 HANDY BOX (2" x 4" x 2 1/8"). PROVIDE RJ45 DATA JACK IN FLOOR BOX. 2 CASHWRAP DATA: TRENCH FLOOR AND ROUTE 2-1 1/4"C WITH CAT5E DATA CABLING TO SURFACE MOUNTED JUNCTION BOX. ROUTE CONDUIT UP THROUGH WALL OR COLUMN TO DESTINATION INDICATED. PROVIDE RJ45 JACKS IN CASHWRAP FIXTURE. VERIFY LOCATIONS OF JUNCTION BOX AND DEVICES WITH FIXTURE SHOP DRAWINGS AND ACCESS PANEL LOCATIONS. LEAVE 20' OF SLACK (MEASURED FROM FLOOR) COILED AND LABELED AT EACH END OF RUN. OWNER'S VENDOR TO MAKE ALL FINAL CONNECTIONS. CONDUIT SHALL BE RUN IN COMMON TRENCH WITH CASHWRAP POWER CONDUIT. COORDINATE WITH ARCHITECT, TENANT COORDINATOR, AND ANY OTHER REQUIRED PARTIES PRIOR TO WORK. 3 PROVIDE 1-RJ45 DATA JACK AT 90"AFF FOR LED SCREEN. PROVIDE 2-CAT5e CABLES FROM DATA JACK TO DATA RACK. COORDINATE EXACT LOCATION WITH ARCHITECT. 4 2 -GANG BOX: PROVIDE 2-3/4" CONDUITS TO SALES AREA FOR TERMINATION OF SOUND SYSTEM WIRE AND TERMINATION OF CAT5 CABLE FOR VOLUME CONTROL. VERIFY EXACT LOCATION OF CONDUIT STUB IN SALES AREA WITH ARCHITECT. REFER TO TELEPHONE BOARD DETAIL ON SHEET E2.1.0 FOR EXACT LOCATION. 5 PROVIDE 1 1/2"C CONDUIT WITH PULL STRING AND 3-CAT5e CABLES FROM MALL PHONE ROOM DEMARK TO STORE TELEPHONE BOARD SHOWN ON POWER PLAN FOR TELEPHONE SERVICE. OWNER SI RESPONSIBLE FOR ESTABLISHING TELEPHONE SERVICE. 6 PROVIDE 5 -GANG BOX (FOR VOLUME CONTROL ONLY) AND 3/4"C TO AUDIO EQUIPMENT RACK JUNCTION BOX FOR AUDIO SPEAKER SYSTEM. VERIFY EXACT LOCATION AND ALL REQUIREMENTS WITH ARCHITECT PRIOR TO BID. RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER a,c)21 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 PROJECT NAME: w U oo v)co co CO Q wQ z� U 5 0 co ISSUANCE DESCRIPTION Lu 0 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME LOW VOLTAGE PLAN CHK BY: EJR DWN BY: EFO SHEET NUMBER E310 SCALE: 1/4" = l'-0" FEEDER SCHEDULE FUSE OR C/B SIZE TAG* COPPER WIRE 20/3 20 4#12,1#12GND-3/4"C 25/3 25 4#10,1#10GND-3/4"C 30/3 30 4#10,1#10GND-3/4"C 35/3 35 4#8,1#10GND-3/4"C 40/3 40 4#8,1#10GND-3/4"C 45/3 45 4#6,1#10GND-1"C 50/3 50 4#6,1#10GND-1"C 60/3 60 4#4,1#10GND-1 1/4"C 70/3 70 4#4,1#8GND-1 1/4"C 80/3 80 4#3,1#8GND-1 1/4"C 90/3 90 4#2,1#8GND-1 1/4"C 100/3 100 4#2,1#8GND-1 1/4"C 110/3 110 4#2,1#6GND-1 1/4"C 125/3 125 4#1,1#6GND-1 1/2"C 150/3 150 4#1/0,1#6GND-2°C 175/3 175 4#2/0,1#6GND-2"C 200/3 200 4#3/0,1#6GND-3°C 225/3 225 4#4/0,1#4GND-3°C 250/3 250 4#250KCMIL,1#4GND-3"C 300/3 300 4#350KCMIL,1#4GND-3"C 350/3 350 4#500KCMIL,1#3GND-4"C 400/3 400 4#500KCMIL,1#3GND-4"C 450/3 450 2 -SETS 4#4/0,1#2GND-3"C 500/3 500 2 -SETS 4#250KCMIL,1#2GND-3"C 600/3 600 2 -SETS 4#350KCMIL,1#1GND-3"C 700/3 700 2 -SETS 4#350KCMIL,1#1/OGND-3°C 800/3 800 2 -SETS 4#600KCMIL,1#1/OGND-4"C 1000/3 1000 3 -SETS 4#400KCMIL,1#2/OGND-3"C 1200/3 1200 3 -SETS 4#600KCMIL,1#3/OGND-4"C 1600/3 1600 4 -SETS 4#600KCMIL,1#4/OGND-4°C NOTES: 1. ALL FEEDER SIZES LISTED MAY NOT BE USED IN PROJECT RISER DIAGRAM. 2. ELECTRICAL CONTRACTOR TO VERIFY CONDUIT SIZE REQUIRED IF WIRE TYPES OTHER THAN THOSE LISTED ABOVE ARE USED. REFER TO APPLICABLE VERSION OF THE NEC. 3. IF CONDUIT OTHER THAN "EMT" IS REQUIRED BASE BID ON NEXT TRADE SIZE ABOVE THAT INDICATED. 4. "IG" TAG INDICATES CONTRACTOR TO PROVIDE ADDITIONAL IG WIRE (SIZED THE SAME AS THE NORMAL GROUND WIRE) WITHIN THE CONDUIT INDICATED. TRANSFORMER SCHEDULE (480V DELTA TO 208/120V -30-4W) XFMR KVA 15 30 45 75 112.5 150 480V OVERCURRENT 30A/3P 50A/3P 70A/3P 125/3P 200A/3P 300A/3P XFMR 3#10 3#6 3#4 3#2 3#3/0 3#35O PRIMARY 1#10GND 1#10GND 1#8GND 1#6GND 1#6GND 1#4GND (TP) 3/4"C 3/4"C 1"C 1-1/4"C 2"C 3"C 208/120V OVERCURRENT 50A/3P 100A/3P 150A/3P 225A/3P 400A/3P 500A/3P XFMR 4#6 4#2 4#1 4#4/0 4#500KCMIL 2 RUNS OF: SECONDARY 1#8GND 1#8GND 1#6GND 1#2GND 1#1/OGND 4#250 (TS) 1°C 1-1/4"C 2"C 2 1/2"C 3"C 1#1/OGND VAV-3 277V 10 3.61 15 2#12,1#12GND-3/4"C 3°C XFMR IG 4#6 4#2 4#1 4#4/0 4#500KCMIL 2 RUNS OF: 4#250 SECONDARY (TS IG) 1#8GND 1#8IG 1"C 1#8GND 1#8IG 1-1/4"C 1#6GND 1#6IG 1#2GND 1#2IG 2 1/2"C 1#1/OGND 1#1/OIG 1#1/OGND 1#1/OIG X SPARE 20/1 2"C 10 3°C 3"C WEIGHT (LBS) 220 260 368 585 620 835 DIMENSIONS 27°x20"x16" 27"x20"x16" 30"x20"x20" 37"x30"x20" 37"x30"x24" 44"x32°x27° NOTES: 1. ALL TRANSFORMER SIZES LISTED MAY NOT BE USED IN PROJECT RISER DIAGRAM. 2. PHYSICAL DIMENSIONS AND WEIGHTS OF TRANSFORMERS MAY VARY DEPENDING ON MANUFACTURER. VERIFY SIZE WITH MANUFACTURER PRIOR TO PURCHASE. 3. "IG" TAG INDICATES CONTRACTOR TO PROVIDE ADDITIONAL IG WIRE (SIZED THE SAME AS THE NORMAL GROUND WIRE) WITHIN THE CONDUIT INDICATED. PROVIDE ISOLATED GROUND BAR IN PANELS L & R. REFER TO DETAIL. PANEL R 208/120V 100A PANEL L 208/120V 225A ETR 75KVA XFMR 480t-208Y/120V TS -IG TENANT STOCK ROOM -.a PANEL MDP 480/277V 125A (ETR) TP 125AS 125AF (ETR) LANDLORD'S ELECTRICAL ROOM Ow - Y n ETR ;) 125A/3P (ETR) EXISTING CIRCUIT BREAKER IN LL GEAR ELECTRICAL LOAD SUMMARY LOAD DESCRIPTION KW (CONNECTED) NEC DEMAND KW (DEMAND) Total Lighting Load "L" 1.18 125% 1.48 Total Track lighting Load "D" 6.48 NEC 8.10 Total Receptacle Load "R" 25.74 NEC 17.87 Total Show Window Load °C" j 0 I FT I 0.72 NEC 0.00 Total Motor Load "M" 7.54 100% 7.54 Total Electric Heat Load "H" 3.00 100% 3.00 Total Misc Load "X" 24.15 100% 24.15 Kitchen Appliance Load °K" 0.00 65% 0.00 Existing Load 0.00 125% 0.00 TOTAL LOAD (KW) 68.80 L 62.13 TOTAL LOAD (AMPS) 82.8 277V 74.7 TRACK LIGHTING LENGTH IS INDICATED AS 0 BECAUSE THE TRACK LIGHTING LOAD "D" IS CALCULATED AT 80% OF THE CURRENT LIMITING DEVICE MECHANICAL/PLUMBING EQUIPMENT CONNECTION SCHEDULE DESCRIPTION VOLTAGE PHASE MCA MOCP CONDUIT AND WIRE PANEL CIRCUIT NUMBER NOTES AHU-1,2,3 208V 10 1.50 15 2#12,1#12GND-3/4"C R 58,60 2 CU -1 208V 10 35.00 50 2#6,1#10GND-3/4"C R 57,59 1 EWH-1 208V 10 14.42 20 2#12,1#12GND-3/4"C L 32,34 3 IWH-1 208V 10 22.00 30 2#10,1#10GND-3/4"C L 36,38 3 VAV-1 277V 10 16.25 25 2#12,1#12GND-3/4"C MDP 13 3 VAV-2 277V 10 16.25 25 2#12,1#12GND-3/4"C MDP 15 3 VAV-3 277V 10 3.61 15 2#12,1#12GND-3/4"C MDP 17 3 NOTES: 1. EC SHALL MOUNT UNIT DISCONNECT SWITCH AND UNPOWERED CONVENIENCE OUTLET. 2 EQUIPMENT PROVIDED WITH INTEGRAL DISCONNECT SWITCH. 3. EC SHALL PROVIDE 20A/2P DISCONNECT SWITCH. #2 REFER TO XFMR GROUNDING DETAIL (TYP) 1 ONE -LINE DIAGRAM E600 SCALE: NONE ONE LINE DIAGRAM NOTES 1. REFER TO FEEDER AND TRANSFORMER SCHEDULES ON THIS SHEET FOR WIRE/CONDUIT SIZES. PANEL NAME CIRCUIT BREAKER REMARKS PANEL CHARACTERISTICS CIRCUIT BREAKER TYPE/ACCESSORY OPTIONS MDP CC=CONTROLLED CIRCUIT, EX=EXISTING LOAD TO REMAIN, ML=MODIFIED LOAD ON EXISTING BREAKER, CL=CIRCUIT WIRED THROUGH CURRENT LIMITER 250 B U S 125 �A M C B 4 80 / 277 ETR AIC A=AFCI, S=SHUNT TRIP, H=HACR G=GFCI, L= C/B LOCK, HT=HANDLE TIE NB=NEW CIRCUIT BREAKER MSUR ACED 3-0 ' 4 tA` MY BUS MATERIAL COPPER Ckt No Breaker LOAD DESCRIPTION Load Type Load VA Phasing Load VA Load Type LOAD DESCRIPTION Breaker Ckt No (Remarks) L1 L2 L3 (Remarks) 1 100/3 NB PANEL L VIA 75KVA TRANSFORMER PNL 17,575 88 X SPARE 30/3 ML 2 3 PNL 19,532 111 CC GENERAL LIGHTING (ZONE 1b) X 4 5 PNL 19,510 1,560 1 TRACK LIGHTING (ZONE 2b) X 6 7 5 20/1 SPACE X L 225 X SPARE 20/1 ML 8 9 6 7 SPACE X HALLWAY LIGHTING (ZONE la) L 35 X SPARE 20/1 ML 10 11 CC s SPACE X CC RESTROOM LIGHTING (ZONE la) L X SPARE 20/1 ML 12 13 25/1 NB VAV-1 X 5,540 CC ORNAMENTAL LIGHTING (ZONE 3) L X SPACE 11 14 15 25/1 NB VAV-2 X 5,540 1 SPARE X SPACE 16 17 15/1 NB VAV-3 X 1,108 15 20/1 CC X SPACE 120 18 PANEL NOTES EXISTING PANEL TO REMAIN. RENAME PANEL AS INDICATED. 48 L 0 NO SUBFEED LOAD SUBFEED LUGS 16 17 0 CC 0 Ltg Load Demand % 120 Total LTG Load "L" (KVA) 1.18 23.11 Total Connected Load in KVA - Phase A ENTRY SIGN (ZONE 4) 1.25 Total Track LTG Load "D" (KVA) 6.48 25.07 Total Connected Load in KVA - Phase B Show Window Length (FT) LED DISPLAY (ZONE 3) Total RECEPT Load "R" (KVA) 25.74 20.62 Total Connected Load in KVA - Phase C 0 Total Show Window Load "C" (KVA) 0.72 68.80 Total Connected Load in KVA - All Phases HVAC Load Demand % 20 Total Motor Load "M" (KVA) 7.54 82.8 Total Connected Load in Amps 1.00 Total Electric Heat Load "H" (KVA) 3.00 62.13 Total NEC Demand Load in KVA - All Phases Misc Load Demand % X Total Misc Load "X" (KVA) 24.15 74.7 Total NEC Demand Load in Amps 1.00 Kitchen Appliance Load "K" (KVA) 0.00 SPARE PANEL NAME CIRCUIT BREAKER REMARKS PANEL CHARACTERISTICS CIRCUIT BREAKER TYPE/ACCESSORY OPTIONS L CC=CONTROLLED CIRCUIT, EX=EXISTING LOAD TO REMAIN, ML=MODIFIED LOAD ON EXISTING BREAKER, CL=CIRCUIT WIRED THROUGH CURRENT LIMITER 225 B U S 225 MCB 208 / 120 1 0 K A I C A=AFCI, S=SHUNT TRIP, H=HACR G=GFCI, L= C/B LOCK, HT=HANDLE TIE N6=NEW CIRCUIT BREAKER MOUNTING SURFACE 'COPPER 3-0 /� 4-W _ BUS MATERIAL COPPER Ckt No Breaker LOAD DESCRIPTION Load Type Load VA Phasing Load VA Load Type LOAD DESCRIPTION Breaker Ckt No (Remarks) L1 L2 L3 (Remarks) 1 20/1 CC GENERAL LIGHTING (ZONE la) L 88 960 D TRACK LIGHTING (ZONE 2a) 20/1 CC 2 3 20/1 CC GENERAL LIGHTING (ZONE 1b) L 88 1,560 D TRACK LIGHTING (ZONE 2b) 20/1 CC 4 5 20/1 CC STOCK ROOM LIGHTING (ZONE la) L 225 I1 1,200 D TRACK LIGHTING (ZONE 2a) 20/1 CC 6 7 20/1 CC HALLWAY LIGHTING (ZONE la) L 35 1,560 D TRACK LIGHTING (ZONE 20) 20/1 CC s 9 20/1 CC RESTROOM LIGHTING (ZONE la) L 16 x 1,200 D TRACK LIGHTING (ZONE 2a) 20/1 CC 10 11 20/1 CC ORNAMENTAL LIGHTING (ZONE 3) L 240 11 360 C SHOW WINDOW TRACK LIGHTING (ZONE 4) 20/1 CC 12 13 20/1 SPARE X 1,080 360 C SHOW WINDOW RECEPTACLES (ZONE 4) 20/1 CC 14 15 20/1 CC COVE LIGHTING (ZONE 3) L 120 48 L ENTRY LIGHTING (ZONE 4) 20/1 CC 16 17 20/1 CC CHANDELIER LIGHTING (ZONE 3) L 120 1,200 X ENTRY SIGN (ZONE 4) 20/1 CC 18 19 20/1 CC LED DISPLAY (ZONE 3) L 200 1,200 X WEST EXTERIOR BLADE SIGN (ZONE 4) 20/1 CC 20 21 20/1 SPARE L 1,080 600 X WEST INTERIOR SIGNS (ZONE 4) 20/1 CC 22 23 20/1 SPARE L 1,080 900 X SOUTHEAST INTERIOR SIGNS (ZONE 4) 20/1 CC 24 25 20/1 SPARE L 1,080 5v -M 720 X SPARE 20/1 L 26 27 20/1 SPARE X 1,440 360 X SPARE 20/1 L 28 29 20/1 SPARE X 900 WaNv 360 X SPARE 20/1 L 30 31 20/1 SPARE X 360 1,500 H EHW-1 20/2 L 32 33 20/1 L SPARE X 1,200 1111 1,500 H 34 35 20/1 34 SPARE X MICROWAVE R 111 2,300 X IWH 1 30/2 R 36 37 100/3 36 PANEL R PNL 9,372 WALL BAY RECEPTACLES SOUTH R 540 2,300 X 38 39 PNL 14,200 20/1 L 38 200 X LCP 20/1 L 40 41 PNL 12,840 360 R MANAGER'S DESK 125 X EM LIGHTING VIA INVERTER 20/1 L 42 PANEL NOTES PROVIDE ISOLATED GROUND BAR. X 0 NO SUBFEED LOAD SUBFEED LUGS R TRAFFIC COUNTER 20/1 0 42 43 20/1 0 Ltg Load Demand % X Total LTG Load "L" (KVA) 1.18 17.57 Total Connected Load in KVA - Phase A X 1.25 Total Track LTG Load "D" (KVA) 6.48 19.53 Total Connected Load in KVA - Phase B Show Window Length (FT) Total RECEPT Load "R" (KVA) 25.74 19.51 Total Connected Load in KVA - Phase C 23 Total Show Window Load °C" (KVA) 0.72 56.62 Total Connected Load in KVA - All Phases HVAC Load Demand % Total Motor Load °M" (KVA) 7.54 157.2 Total Connected Load in Amps 1.00 Total Electric Heat Load "H" (KVA) 3.00 54.54 Total NEC Demand Load in KVA - All Phases Misc Load Demand % Total Misc Load "X" (KVA) 11.96 151.4 Total NEC Demand Load in Amps 1.00 Kitchen Appliance Load "K" (KVA) 0.00 PANEL NAME CIRCUIT BREAKER REMARKS PANEL CHARACTERISTICS CIRCUIT BREAKER TYPE/ACCESSORY OPTIONS R CC=CONTROLLED CIRCUIT, EX=EXISTING LOAD TO REMAIN, ML=MODIFIED LOAD ON EXIST WIRED THROUGH CURRENT LIMITER 100 BUS 100 M L 0 208 / 120 1 0 K A I C A=AFCI, S=SHUNT TRIP, H=HACR G=GFCI, L= C/B LOCK, HT=HANDLE TIE NB=NEW CIRCUIT BREAKER MSUR ACEG 3-04-W BUS MATERIAL COPPER Ckt No Breaker LOAD DESCRIPTION Load Type Load VA Phasing Load VA Load Type LOAD DESCRIPTION Breaker Ckt No (Remarks) L1 L2 L3 (Remarks) 1 20/1 SELFIE STATION RECEPTACLES R 720 180 R ROOFTOP RECEPTACLES 20/1 2 3 20/1 GENERAL SALES RECEPTACLES R 1,260 800 R REFRIGERATOR 20/1 G 4 5 20/1 FLOOR BOX RECEPTACLES R 720 I1 900 R POS GENERAL RECEPTACLES 20/1 6 7 20/1 FLOOR BOX RECEPTACLES R 1,080 180 R POS IG RECEPTACLES 20/1 8 9 20/1 FLOOR BOX RECEPTACLES R 1,080 x 180 R POS IG RECEPTACLES 20/1 10 11 20/1 FLOOR BOX RECEPTACLES R 900 180 R POS IG RECEPTACLES 20/1 12 13 20/1 WALL BAY RECEPTACLES WEST R 1,080 180 R POS IG RECEPTACLES 20/1 14 15 20/1 WALL BAY RECEPTACLES WEST R 720 180 R POS IG RECEPTACLES 20/1 16 17 20/1 WALL BAY MONITOR RECEPTACLES WEST R 900 360 R KITCHEN ISLAND RECEPTACLE (ZONE 3) 20/1 CC 18 19 20/1 WALL BAY MONITOR RECEPTACLES WEST R 1,260 360 R KITCHEN ISLAND RECEPTACLE 20/1 20 21 20/1 WALL BAY RECEPTACLES EAST R 1,080 360 R KITCHEN ISLAND RECEPTACLE (ZONE 3) 20/1 CC 22 23 20/1 WALL BAY RECEPTACLES EAST R 1,080 200 R SENSORMATIC 20/1 L 24 25 20/1 WALL BAY MONITOR RECEPTACLES EAST R 1,080 5v -M 720 R WALL BAY MONITOR RECEPTACLES ENTRANCE 20/1 L 26 27 20/1 WALL BAY MONITOR RECEPTACLES EAST R 1,440 360 R BURGLAR ALARM 20/1 L 28 29 20/1 STOCKROOM/CORRIDOR RECEPTACLES R 900 WaNv 360 R IT RACK 20/1 L 30 31 20/1 RESTROOM RECEPTACLES R 360 360 R IT RACK 20/1 L 32 33 20/1 L HAND DRYER X 1,200 360 R A/V RACK 20/1 L 34 35 20/1 MICROWAVE R 1,500 360 R MANAGER'S DESK 20/1 L 36 37 20/1 WALL BAY RECEPTACLES SOUTH R 540 360 R MANAGER'S DESK 20/1 L 38 39 20/1 WALL BAY MONITOR RECEPTACLES SOUTH R 540 360 R MANAGER'S DESK 20/1 L 40 41 20/1 SPARE X 200 R TRAFFIC COUNTER 20/1 L 42 43 20/1 SPARE X X SPARE 20/1 44 45 20/1 SPARE X X SPARE 20/1 46 47 20/1 SPARE X X SPARE 20/1 48 49 20/1 SPARE X X SPARE 20/1 50 51 20/1 SPARE X X. SPARE 20/1 52 53 20/1 SPARE X X SPARE 20/1 54 55 20/1 L FAEP X 200 200 X EXIT ALARM 20/1 L 56 57 50/2 H CU -1 M 3,640 128 M AHU-1,2,3 15/2 H 58 59 M 3,640 128 M 60 PANEL NOTES PROVIDE ISOLATED GROUND BAR. 0 NO SUBFEED LOAD SUBFEED LUGS 0 0 Ltg Load Demand % Total LTG Load "L" (KVA) 0.00 9.37 Total Connected Load in KVA - Phase A 1.25 Total Track LTG Load "D" (KVA) 0.00 14.20 Total Connected Load in KVA - Phase B Show Window Length (FT) Total RECEPT Load "R" (KVA) 25.74 12.84 Total Connected Load in KVA - Phase C 0 Total Show Window Load "C" (KVA) 0.00 36.41 Total Connected Load in KVA - All Phases HVAC Load Demand % Total Motor Load "M" (KVA) 7.54 101.1 Total Connected Load in Amps 1.00 Total Electric Heat Load "H" (KVA) 0.00 28.54 Total NEC Demand Load in KVA - All Phases Misc Load Demand % Total Misc Load "X" (KVA) 3.14 79.2 Total NEC Demand Load in Amps 1.00 Kitchen Appliance Load "K" (KVA) 0.00 REVIEWED FOR COMPLIANCE WITH NFPA70-NEC APR 12 2018 City of .Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 27 2018 PERMIT CENTER 21L CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 MAR 2 0 2018 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME ONE LINE & PANEL SCHEDULES DWN BY: EFO CHK BY: EJR SHEET NUMBER SCALE: AS NOTED GREENMAX HANDHELD DISPLAY UNIT & BRACKET (RHDU1-300 + RHDU1-BKT) MOUNT TO INTERIOR OF RELAY CABINET DOOR LCP S# CORRIDOR OCCUPANCY SENSOR OSC10-MOW S STOCK ROOM riikk LVF ZONE SWITCH W/ OVERRIDE LC STOCK ROOM (2) 4 BUTTON STATIONS (2) RDGSW-4CW 2 BUTTON STATION RDGSW-2CW OCCUPANCY SENSOR OSC10-MOW 1 OVERALL SYSTEM WIRING DIAGRAM E601 SCALE: NONE 0 LIGHTING CONTROL WIRING KEYNOTES 1 REFER TO DEVICE CIRCUIT SCHEDULE(S) OR DEVICE TYPE FOR ASSOCIATED FEED AND LOAD CIRCUIT QUANTITY AND TYPE(S). 2 GREENMAX CONTROL POWER: 1A, 120V, 2 WIRE PLUS GROUND, 60HZ. DEDICATED SOURCE. POWER SHOULD BE PROVIDED TO THE CONTROL PROCESSOR IN BOTH NORMAL AND EMERGENCY CONDITIONS, IF CONTROL IS REQUIRED UNDER EMERGENCY CONDITIONS. 3 SENSOR: (4) #18 AWG STRANDED CU CONTROL CONDUCTORS PER DEVICE, LABELED SPARE, +24V, COM, S#. S# CORRESPONDS TO THE CONNECTED CABINET'S ANALOG INPUT NUMBER OCC/PHOTO, OR TO THE LOCATION OF THE DEVICE AS RECORDED BY E.C. 4 (1) GREENMAX LUMACAN CABLE: BELDEN 2412 TERMINATED PER EIA/TIA 568B LABELED PER DRAWING. DISCONNECT +V BETWEEN POWER SOURCES. A DISCONNECT SWITCH IS PROVIDED FOR THIS PURPOSE. GRAY RELAY-1DS LINE FEED VIOLET INE LOAD LINE (BLK) NEU (WHT) GND RELAY-1TB LINE FEED LINE LOAD LIGHTING LOAD LINE (BLK) NEU (WHT) GND LIGHTING LOAD 4 LIGHT FIXTURE WIRING DIAGRAM E601 SCALE: NONE LINE FEED LINE (BLK) NEU (WHT) LOW -VOLTAGE AREA POWER MPU LV IN SUPPLY ZONE CIRCUIT GENERA LTG 8 RELAY # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 WIREWAY ZE H D TYPICAL GREENMAX RELAY CABINET WIRE RUN BETWEEN RELAY AND ANALOG INPUT. (2) #18 AWG STRANDED CU CONDUCTORS, TYPICAL. USE RELAYS THIS SIDE OF CABINET, AT TOP. USE BARRIER TO SEPARATE LOW VOLTAGE FROM HIGH VOLTAGE SECTIONS OF CABINET. 2 RELAY WIRING DIAGRAM E601 SCALE: NONE LIGHTING CONTROL GENERAL NOTES 1. THIS DIAGRAM REPRESENTS A TYPICAL SYSTEM AND IS NOT INTENDED FOR INSTALLATION. SYSTEM SUPPLIER SHALL PROVIDE INSTALLATION DRAWINGS AND SCHEMATIC WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL BE COORDINATED WITH THE SYSTEM SUPPLIER. 2. LIGHTING CONTROL EQUIPMENT SHALL BE BY LEVITON. NO SUBSTITUTIONS ALLOWED. 3. LIGHTING CONTROL EQUIPMENT SHALL BE PROVIDED AND INSTALLED BY GENERAL CONTRACTOR. 4. REFER TO INSTALLATION INSTRUCTIONS FOR WIRING AND CONNECTION INFORMATION. DIAGRAM ABOVE PROVIDED FOR REFERENCE ONLY. 5. ALL WIRING TO BE INSTALLED IN CONDUIT, 3/4" MINIMUM 6. PROVIDE ALL ADDITIONAL EQUIPMENT AND HARDWARE REQUIRED FOR A COMPLETE INSTALLATION. GREENMAX RELAY CABINET TYPICAL RELAY OCCUPANCY SENSOR OSSMD-MDW 5 WALL SENSOR WIRING DIAGRAM E601 SCALE: NONE TYPICAL 2 -BUTTON STATION LABELING ZONE la r' ZONE lb ZONE 2a ZONE 2b ZONE 3 r' ZONE 4 ALL ON I-1 ALL OFF r7 ZONE SWITCH WITH OVERRIDE LABELING 3 CONTROL STATION LABELING E601 SCALE: NONE LIGHTING CONTROL PANEL SCHEDULE RELAY # TYPE LOAD NAME ZONE CIRCUIT GENERA LTG 8 RELAY # TYPE LOAD NAME ZONE CIRCUIT 1 SM GENERAL LIGHTING la L-1 1. VERIFY ZONING AND SCHEDULING WITH OWNER. 17 SM LED .DISPLAY 3 L-19 2 2: -BUTTON CONTROL STATION GENERAL LIGHTING ib L-3 2 18 SM SHOW WINDOW TRACK LIGHTING 4 L-12 3 SM STOCK ROOM LIGHTING la L-5 2- NG WALL PLATE 19 SM SHOW WINDOW RECEPTACLES 4 L-14 4 SM HALLWAY LIGHTING la L-7 20 SM ENTRY LIGHTING 4 L-16 5 SM RESTROOM LIGHTING is L-9 21 SM ENTRY SIGN 4 L-18 6 SM TRACK LIGHTING 2a L-2 22 SM WEST EXTERIOR BLADE SIGN 4 L-20 7 SM TRACK LIGHTING 2b L-4 23 SM WEST INTERIOR SIGNS 4 L-22 8 SM TRACK LIGHTING 2a L-6 24 SM SOUTHEAST INTERIOR SIGNS 4 L-24 9 SM TRACK LIGHTING 2b L-8 25 SPARE 10 SM ; TRACK LIGHTING 2a L-10 26 SPARE 11 SM ORNAMENTAL LIGHTING 3 L-11 27 SPARE. 12 SM SPARE 28 SPARE 13 SM COVE LIGHTING 3 1-15 29 SPARE 14 SM CHANDELIER LIGHTING 3' L-17' 30 SPARE 15 SM KITCHEN ISLAND RECEPTACLE 3 R-18 31 SPARE 16 SM KITCHEN ISLAND RECEPTACLE 3 R-22 32 SPARE. LIGHTING CONTROL ZONES ZONE # LOAD TYPE la GENERAL LTG A ib GENERA LTG 8 2a TRACK LTG A/ACCESSORIES LTG'. 2b TRACK LTG 8 3 ORNAMENTAL/GOVE/KITCHEN'RECEPTS 4 SHOW WINDOW/SIGNAGE NOTES: 1 1. VERIFY ZONING AND SCHEDULING WITH OWNER. 2. ZONE 4 SHALL BE CONTROLLED VIA TIMEGLOCK ONLY, NO MANUAL CONTROLS. RILL OF MATERIALS QTY SPEC # DESCRIPTION 1 R32TC-100 32 -RELAY: CABINET 1 RP 11S -31S MAIN COMMAND MODULE 2 81616 -ITB RELAY INSERT PANEL (SWITCH): 1 R1600-000 VOLTAGE BARRIER 1 RHDU1-300 HANDHELD DISPLAY' UNIT 1 RHDU1-BKT HDU MOUNTING BRACKET 1 RDGSW-2CW 2: -BUTTON CONTROL STATION 1 RDGSW-2FW COLOR CHANGE KIT W/ ENGRAVING 2 ROGSW-4CW 4 -BUTTON CONTROL STATION 2 RDGSW-4FW COLOR CHANGE KIT W/ ENGRAVING 2 0SC10-MOW CEILING OCCUPANCY SENSOR (1000SF) 1 80309 -SW 2- NG WALL PLATE 1 OSSMD.-MDW WALL OCCUPANCY SWITCH TRACK LTG BRANCH CIRCUITS TO FIXTURES CURRENT LIMITING PANEL "CLP" JUNO TRAC-MASTER CURRENT LIMITING PANEL CLS6M TRACK LTG BRANCH CIRCUITS FROM LCP REVIEWED FOR COMPLIANCE WITH NFPA7O-NEC APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA 6 CURRENT LIMITING PANEL DIAGRAM PE E601 SCALE: NONE SIZE OF CL (W) MAR 2 7 2018 RMIT CENTER CURRENT LIMITER PANEL CKT # # HEADS CKT WATTAGE SIZE OF CL (A) SIZE OF CL (W) % LOADED L-2 28 700 8 960 72.9 L-4 48 1200 13 1560 76.9 L-6 48 1200 13 1560 76.9. 1-8 48 1200 13 1560 76.9 L-10 27 675 8 960 70.3 L-11 15 150. 2 240 62.5 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND `f MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER ENGINEERING 25760 First Street Cleveland, 01-I 44145 P 440 871 2410 F 440 871 7954 w U Q. 00 CO r J 00 J O) Q Q W I- J Z w� U � 1— 0r^ v/co Z 0 H 2 SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME LIGHTING CONTROL SCHEDULE & DETAILS D BY: EFO CHK BY: EJR SHEET NUMBER E601 SCALE: NONE FIRE ALARM NOTES 1. PRINCIPAL OCCUPANCY CLASSIFICATION IS GROUP M. 2. SPACE IS PROVIDED WITH FULL SPRINKLER COVERAGE. 3. OCCUPANT LOAD IS LESS THAN 500. 4. SPACE IS WITHIN A COVERED MALL COMPLYING WITH IBC 402. 5. THE LANDLORD DOES REQUIRE ALL TENANTS TO INSTALL A FIRE ALARM SYSTEM MONITORED BY THE LANDLORD SYSTEM. 6. A FIRE ALARM SYSTEM IS REQUIRED. 7. AIR HANDLING SYSTEMS WITH AN AGGREGATE CAPACITY OVER 2,000 CFM REQUIRE DUCT SMOKE DETECTORS WITH LOCAL VISIBLE AND AUDIBLE SUPERVISORY SIGNAL. DUCT SMOKE DETECTOR MONITORING SHALL BE BY OTHERS UNDER SEPARATE CONTRACT WITH THE OWNER. 8. FIRE ALARM SYSTEM INSTALLED OR MODIFIED BY THIS CONTRACTOR IS TO BE VERIFIED AND CERTIFIED BY AHJ AT THIS CONTRACTOR'S EXPENSE. ELECTRICAL SPECIFICATIONS I. A. DIVISION 26 - ELECTRICAL GENERAL PROVISIONS GENERAL CONDITIONS, CODES & STANDARDS 1. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) AND ANY OF THE OWNER'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. 2. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. 3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE OWNER REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. 4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS. 5. ALL EQUIPMENT AND MATERIALS USED SHALL BE NEW AND UL LISTED FOR THE APPLICATION, AND SHALL BEAR AN APPROPRIATE UL LABEL. B. SCOPE OF WORK 1. THIS CONTRACT SHALL. INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE OWNER A COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEM. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE WORK IS COMMENCED. 3. CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND ELECTRICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. 5. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS, AND WALLS PENETRATED. 6. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REQUIREMENTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED WIRING AND CONDUIT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 8. THIS CONTRACT SHALL ALSO INCLUDE ALL LABOR, MATERIALS AND MISCELLANEOUS EXPENSES REQUIRED FOR ALL REQUIRED ELECTRICAL DEMOLITION OF THE EXISTING AREAS BEING RENOVATED. a. THE DEMOLITION SHALL CONSIST OF THE COMPLETE REMOVAL (PROPERLY DISPOSED OFF SITE UNLESS OTHERWISE NOTED) OF ALL ELECTRICAL EQUIPMENT, WIRING, CONDUIT, MATERIALS, ETC. NOT REQUIRED IN THE FINAL DESIGN AND INSTALLATION OF THE ELECTRICAL SYSTEMS FOR THE NEW RENOVATED AREAS. b. ALL UNDERGROUND SERVICES NOT BEING REUSED SHALL BE CAPPED BELOW THE FLOOR, WIRING REMOVED, AND FLOOR PENETRATIONS REPAIRED TO MATCH ADJACENT SURFACES. c. ALL ABOVE GROUND CIRCUITS SHALL BE REMOVED BACK TO THE SOURCE UNLESS INDICATED OTHERWISE. d. COORDINATE ALL DEMOLITION WITH THE ARCHITECTURAL DOCUMENTS, THE ARCHITECT, AND THE OWNER'S GENERAL REQUIREMENTS. 9. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND OWNER. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. C. DOCUMENTS 1. THE DRAWINGS ARE DIAGRAMMATIC; ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE OWNER. 2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOTH. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. 5. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL AND MUST BE SUBMITTED AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. COORDINATION 1. CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 2. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB -TRADE'S PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC. SHALL BE DONE AS DIRECTED BY THE OWNER BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 3. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AT SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE OPERATIONS OF THE SPACE, ADJACENT SPACES, OR FACILITY. A WORK SCHEDULE SHALL BE ARRANGED WITH THE OWNER, INCLUDING PREMIUM TIME WORK TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE TO THE OWNER'S OPERATIONS. E. METHODS i. EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. CONDUIT SHALL BE LAID ON AN APPROPRIATELY GRADED 6' BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO BACKFILL TO 6" ABOVE THE CONDUIT. BACKFILL THE REMAINDER OF THE TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE OWNER. IF THE EXCAVATED MATERIALS ARE NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL SHALL BE ACCOMPLISHED IN 9" LIFTS WITH ALL LIFTS COMPACTED TO 95% PROCTOR. PATCH FLOOR TO MATCH EXISTING. 2. EQUIPMENT, CONDUIT, ETC. SHALL NOT BE SUPPORTED FROM ANY CEILINGS, OTHER PIPING, OTHER CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 3. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL BE PERFORMED BY THE OWNER'S ROOFING CONTRACTOR AT THE REQUESTING CONTRACTORS COST. F. SUBMITTALS 1. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT OF ALL EQUIPMENT AND ACCESSORIES PROVIDED FOR THE PROJECT WHETHER SPECIFIED HERE -IN OR ON THE DRAWINGS. REVIEW OF THE SHOP DRAWINGS SHALL BE FOR GENERAL DESIGN CONCEPT AND ADHERENCE WITH THE SPECIFICATIONS. QUANTITY OF SHOP DRAWINGS SUBMITTED SHALL BE AS SPECIFIED BY THE ARCHITECT. SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR SHOWING LOCATIONS AND MEASUREMENTS FROM COLUMNS OF ALL CONCEALED AND EXPOSED PIPING, DUCTWORK, CONDUIT, EQUIPMENT, ACCESSORIES, ETC., AND SUBMITTED PRIOR TO INSTALLATION. THE OWNER MAY MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP DRAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFIRMING ALL INFORMATION ON THE DRAWINGS PRIOR TO FABRICATION AND/OR INSTALLATION. 2. PROJECT RECORD DOCUMENTS - MAINTAIN AT THE JOBSITE ONE COPY OF ALL CONTRACT DOCUMENTS CLEARLY MARKED AS "PROJECT RECORD COPY". THESE DRAWINGS ARE TO BE MAINTAINED IN GOOD CONDITION, UPDATED DAILY FOR CHANGES ENCOUNTERED AND AVAILABLE AT ALL TIMES FOR INSPECTION BY THE OWNER. DO NOT USE FOR FIELD CONSTRUCTION! PROJECT RECORD DOCUMENTS ARE TO BE KEPT CURRENT WITH EXACT DIMENSIONS OF ALL WORK, EQUIPMENT, DISTRIBUTION CONDUIT, CIRCUITS, ETC. MARK ALL INFORMATION IN RED LINES AND NOTES SO AS TO BE EASILY IDENTIFIED FROM THE BASE DRAWING. UPON COMPLETION OF THE WORK, ONE SET OF THESE DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AS ONE QUALIFICATION FOR FINAL PAYMENT. 3. THREE COMPLETE SETS OF AS -BUILT DOCUMENTATION SHALL BE PROVIDED. IT SHALL INCLUDE, BUT NOT BE LIMITED TO ACCURATE PLAN DRAWINGS, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. II. PRODUCTS A. CONDUIT 1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO DAMAGE, 8'-0" AFF AND BELOW. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED (3' MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLAD (MC) CABLE MAY BE USED IF APPROVED BY THE OWNER, AND INSTALLED IN LOCATIONS PERMITTED BY CODE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION. B. CONDUIT FITTINGS AND BOXES 1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSTALLED. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED CORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT. 2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SQUARE, 1-1/2 INCHES DEEP. 3. COUPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL. BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. 4. FLOOR BOXES SHALL BE FLUSH SERVICE TYPE., RECTANGULAR CAST METAL CONSTRUCTION GANGABLE ADJUSTABLE WITH BRASS (ALUMINUM) COVER AND TRIM/FLANGE AS REQUIRED. COVER TYPE SHALL BE AS INDICATED ON LEGEND. C. WIRE AND CABLE 1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW 600 -VOLT, 90°C, TYPE XHHW, THHW, OR THWN INSULATION, MINIMUM SIZE #12 -AWG, EXCEPT FOR CONTROL WIRING WHICH MAY BE #14 -AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BY THE OWNERH. 2. BRANCCIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE LAST DEVICE, SHALL BE #10 -AWG CONDUCTORS UNLESS OTHERWISE NOTED. 3. COMPRESSION TYPE LUGS AND CONNECTORS SHALL BE USED FOR ALL TERMINATIONS AND SPLICES. 4. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED. D. WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 3. COLORS OF DEVICES SHALL BE SELECTED BY ARCHITECT. 4. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC. E. LIGHTING AND RECEPTACLE PANELBOARDS 1. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A SURFACE OR FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 18,000 AMPS SYMMETRICAL FOR 277/480V APPLICATION UNLESS NOTED OTHERWISE. 2. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE; WITH MOLDED PLASTIC CASE; 1, 2, OR 3 POLE AS INDICATED; QUICK -MAKE, QUICK -BREAK; AND THERMAL -MAGNETIC TRIP DEVICE. 3. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACR RATED, UNLESS OTHERWISE NOTED. 4. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. 5. INDIVIDUAL SINGLE POLE CIRCUIT BREAKERS, WITH IDENTIFIED TIES, OR 2/3 POLE BREAKERS SHALL BE PROVIDED FOR EACH UNGROUNDED CONDUCTOR IN ALL MULTI -WIRE BRANCH CIRCUITS. 6. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS, AND CUTLER HAMMER. F. SAFETY SWITCHES AND MOTOR STARTERS 6. SAFETY SWITCHES SHALL BE FUSIBLE OR NON -FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSES SHALL BE DUAL ELEMENT - TIME DELAY TYPE. 7. MAGNETIC MOTOR STARTERS SHALL BE COMBINATION TYPE WITH THERMAL OVERLOAD, INTEGRAL FUSED SAFETY SWITCH, H -O -A SELECTOR SWITCH, CONTROL TRANSFORMER, RUNNING PILOT LIGHT, NEMA TYPE 1 ENCLOSURE, AND (2) NORMALLY OPEN AND (2) NORMALLY CLOSED AUXILIARY CONTACTS. 8. ALL MOTORS OVER 1/8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS AND/OR MOTOR CONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS. 9. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. H. LUMINAIRES AND LAMPS 1. ALL LUMINAIRES SHALL BE SPECIFIED ON THE LUMINAIRE SCHEDULE. 2. EMERGENCY LIGHTING AS INDICATED, SHALL PROVIDE A MINIMUM OF ONE FOOTCANDLE ALONG THE PATH OF EGRESS. EMERGENCY FIXTURE SUPPLIER SHALL PROVIDE FOOTCANDLE PRINTOUT TO VERIFY EMERGENCY LIGHT LEVELS. 3. ALL FIXTURE / BALLAST / LAMP COMBINATIONS SHALL BE ENERGY SAVING TYPE. 4. FOLLOW MANUFACTURER'S GUIDELINES AND REQUIREMENTS FOR INSTALLATION OF LUMINAIRES AND LAMPS. LUMINAIRES AND LAMPS SHALL BE CLEANED TO REMOVE ALL VISIBLE DIRT AND FINGERPRINTS. I. FIRE ALARM SYSTEM 1. A COMPLETE EXTENSION OF THE LANDLORD'S FIRE ALARM SYSTEM SHALL BE PROVIDED AS DESCRIBED ON THE DRAWINGS. ALL DEVICES, WIRING, BACKBOXES, PROGRAMMING, START-UP, INSTRUCTION AND TESTING REQUIRED FOR A COMPLETE OPERATING SYSTEM SHALL BE PROVIDED. 2. THE ELECTRICAL CONTRACTOR SHALL FURNISH SHOP DRAWINGS, COMPLETE WITH EQUIPMENT CUTS AND FLOOR PLANS (WITH WIRING INDICATED), AS WELL AS BATTERY CALCULATIONS, AND VOLTAGE DROP CALCULATIONS FOR REVIEW AND APPROVAL BY THE ARCHITECT, ENGINEER, AND ALL AUTHORITIES HAVING JURISDICTION. FLOOR PLAN DRAWINGS SHALL BE STAMPED BY A PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR AND/OR SUPPLIER. NICET 4 CERTIFICATION AND STAMP IS ACCEPTABLE, IF APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. THE ELECTRICAL CONTRACTOR SHALL FURNISH FIRE ALARM DRAWINGS, CALCULATIONS, AND EQUIPMENT INFORMATION FOR ALL REQUIRED LOCAL MUNICIPALITY, OR STATE PERMITS. THE ELECTRICAL CONTRACTOR SHALL ARRANGE AND COORDINATE ALL REQUIRED TESTING AND INSPECTIONS REQUIRED BY THE LOCAL MUNICIPALITY FIRE DEPARTMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE FIRE DEPARTMENT COSTS IN BID. 4. ALL HVAC UNITS OR GROUP OF HVAC UNITS WITH A COMMON PLENUM AND A DESIGN CAPACITY GREATER THAN 2000 CFM SHALL AUTOMATICALLY SHUT DOWN ASSOCIATED HVAC UNIT OR UNITS. WHERE A DUCT SMOKE DETECTOR IS NOT VISIBLE OR ACCESSIBLE FROM THE FLOOR, REMOTE AUDIBLE/VISUAL ALARM INDICATOR/TEST SWITCHES SHALL BE PROVIDED IN AN APPROVED LOCATION, AT A HEIGHT ACCESSBILE AND VISIBLE FROM THE FLOOR. HVAC DUCT DETECTORS SHALL BE CONNECTED TO A CENTRAL STATION MONITORING SYSTEM UNDER SEPERATE CONTRACT WITH THE OWNER. 5. FIRE ALARM SIGNAL SHALL INITIATE THE FOLLOWING ACTIONS: a. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. b. IDENTIFY ALARM AND SPECIFIC INITIATION DEVICE AT FIRE CONTROL PANEL. c. TRANSMIT ALARM TO LANDLORD SYSTEM. d. TRANSMIT ALARM SIGNAL TO REMOTE RECEIVING STATION. e. INTERRUPT TENANT SOUND SYSTEM. f. SHUT DOWN AIR HANDLING SYSTEMS. 6. ALL FIRE ALARM VISIBLE DEVICES SHALL BE ADA COMPLIANT WITH A MINIMUM CANDELA RATING OF 75. CEILING MOUNTED DEVICES SHALL HAVE A RATING WITH THE LISTED REQUIREMENTS FOR A SPECIFIC CEILING HEIGHT. 7. ALL WALL MOUNTED STROBES, SPEAKER -STROBES, OR HORN STROBES SHALL BE MOUNTED SUCH THAT THE LENS IS NOT LESS THAN 80 INCHES AND NOT MORE THAN 96 INCHES ABOVE THE FINISHED FLOOR. 8. ALL AUDIBLE NOTIFICATION APPLIANCES SHALL BE SET TO ACHIEVE A SOUND PRESSURE AT LEAST 15dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL. 9. ALL CABLES FOR THE FIRE ALARM SYSTEM SHALL BE RATED FOR THE INTENDED USE. 10. FIRE ALARM SYSTEM MONITORING SHALL BE BY OTHERS UNDER SEPARATE CONTRACT WITH THE OWNER. 11. PROVIDE A SEPARATE LINE ITEM COST FOR A (1), (3), (5) YEAR MAINTENANCE, TESTING AND MONITORING AGREEMENT. AGREEMENT TO INCLUDE MONITORING TO A UL LISTED CENTRAL STATION PER NFPA 72 REQUIREMENTS, ALL CODE REQUIRED TESTING OF THE FIRE ALARM SYSTEM PER NFPA 72 AND OBC (MONTHLY VISUAL INSPECTION SHALL BE BY THE OWNER), CLEANING OF DEVICES SHALL BE DONE UPON SYSTEM REQUEST, AND ALL COST ASSOCIATED WITH MAINTENANCE OF THE SYSTEM SHALL BE PROVIDED (DUE TO DEFECTIVE EQUIPMENT ONLY). PROVIDE A YEARLY REPORT TO THE OWNER. 12. FIRE ALARM SYSTEM SHALL MATCH LANDLORD'S EXISTING SYSTEM. III. EXECUTION A. GENERAL MISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4" SHALL NOT BE USED FOR ANY CIRCUIT HOMERUNS. 2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL CODE. 3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410-30 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES WHICH MY APPLY. 5. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. 6. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 7. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 8. THE ELECTRICAL CONTRACTOR SHALL BALANCE PANELBOARD LOADING TO WITHIN 10% ON EACH PHASE BASED ON INSTALLED CONDITIONS. LOAD BALANCING CIRCUIT CHANGES SHALL BE PERFORMED OUTSIDE THE NORMAL OCCUPANCY WORKING SCHEDULE AND AT A TIME DIRECTED BY LANDLORD. 9. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO ADDITIONAL COST TO THE OWNER. 10. CONTACT TELEPHONE COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR TELEPHONE SERVICE. 11. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING OWNER'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING OF DEBRIS. B. GROUNDING 1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON-CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 250. 2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. LUMINAIRE SCHEDULE TYPE WATTAGE DESCRIPTION CATALOG NUMBER VOLTAGE LAMP FIXTURE DP1 LED 150W FIXTURE: MODERN SOCKET. 16' CORD LENGTH. WHITE CORD COLOR. GOLD FINISH. LAMP: 350 LUMENS, 2700K FIXTURE MANUFACTURER: TECH LIGHTING CAT#: 700TDSOCOPM16WG/T31WH LAMP MANUFACTURER: AAMSCO CAT#: LED-4W-G4OHYBRID-DIM ACCESSORIES: T31 WH 120V DP2 LED - FIXTURE: BAMBOO CHANDELIER LAMP: FROSTED FINISH. DIMMABLE, 350 LUMENS. 2700K FIXTURE MANUFACTURER: JONATHAN ADLER CAT#: MEURICE RECTANGULAR CHANDELIER BRASS LAMP MANUFACTURER: SUNLITE CAT#: 80651 -SU 120V El LED 3W LED EXIT SIGN. RED LETTER COLOR, SINGLE/CLEAR PANEL COLOR. WHITE HOUSING FINISH. 90 MINUTE BATTERY BACKUP. FIXTURE MANUFACTURER: NORA LIGHTING CAT#: NX -608 -R -1-W 120V E2 LED 4W THERMOPLASTIC LED EXIT SIGN. UNIVERSAL/SINGLE DOUBLE FACE. RED LETTERS, WHITE FINISH. 90 MINUTE BATTERY BACKUP. FIXTURE MANUFACTURER: JUNO CAT#: NXPB-3-R-WH 120V EM1 LED LED THERMOPLASTIC EMERGENCY LIGHT. PROVIDES 90 MINUTES OF BATTERY BACKUP. 536 TOTAL LUMENS, WHITE HOUSING COLOR. FIXTURE MANUFACTURER: LITHONIA CAT#: ELM6-LED-W-LP03VS-T20C 120V LA1 LED 16W MX G2 SEMI RECESSED MULTIPLE TRIMLESS (1) HEAD W/ NEW CONSTRUCTION FRAME -IN. 1350 DELIVERED LUMENS, 3000K/82 CRI. 36° FLOOD. WHITE HEAD & FLANGE FINISH. 0-10V DIMMING 1% FIXTURE MANUFACTURER: INTENSE CAT#: MXG2SRTL1L130936WD101-IP2-4FK-I-TLD101-1200 120V LD1 LED 16W 3.5" MX G2 LED TRIMLESS DOWNLIGHT. 1300 DELIVERED LUMENS, 3000K/82 CRI. WHITE FINISH. 0-10V DIMMING 1% FIXTURE MANUFACTURER: INTENSE CAT#: MXG2DRTL-NCL1D101-MXTG2-RTLD300WL130924-1200 120V LP1 LED 11W CORE 400 SX PENDANT. DEEP CANOPY DRIVER LOCATION. 0-10V DIMMING. DAMP MOUNTING LOCATION. 930 LUMENS, 3000K. 83° REFLECTOR. WHITE CORD SUSPENSION. FIXTURE MANUFACTURER: V2 LIGHTING CAT#: C4SP-D-V-D-10-98-30-83-T1-WH 120V LP1EM LED 11W SAME AS FIXTURE "LP1" EXCEPT WIRED TO LED INVERTER FOR EMERGENCY OPERATION WITH 90 MINUTES OF BATTERY BACKUP. FIXTURE MANUFACTURER: V2 LIGHTING CAT#: C4SP-D-V-D-10-98-30-83-T1-WH 120V LS1 LED 3W/FT HIGH PERFORMANCE LED STRIP. 3000K, 253 LUMENS/FT. SOLDERED LEAD WIRES (72") AR SECTION START, NO CONNECTOR AT SECTION END. FIXTURE MANUFACTURER: LUMINII CAT#: LL36-30K-SL-NC/PSV-96-24-US-DIM-D 120V LS2 LED 25W 4' LED COMMERCIAL LED STRIPLIGHT. LED 5.0, 3000LUMENS, 3000K. WIDE FULL FROST LENS. (1) 0-10V DIMMING DRIVER, UNIT PACK. FIXTURE MANUFACTURER: METALUX CAT#: 4SNLED-LD5-30SL-LW-UNV-L830-CD1-U 120V LT1 LED 25W LED TRACK HEAD 3-5/16DIA x 5-1/8"L 24 DEGREE BEAM, PHILIPS LIGHTOLIER LC -[TRACK ADAPTOR]-20-930-[FINISH]-TELLAV11-RNF 120V LT2 LED 25W LED TRACK HEAD 3-5/16DIA x 5-1/8"L 36 DEGREE BEAM. PHILIPS LIGHTOLIER LC -[TRACK ADAPTOR] 20 930 -[FINISH] TELLAV11-RF-FR 120V TT1 SURFACE MOUNTED SINGLE CIRCUIT TRACK. PHILIPS LIGHTOLIER LYTESPAN 1 CIRCUIT TRACK 120V LIGHTING FIXTURE NOTES: A. REFER TO WORK RESPONSIBILITY MATRIX FOR PROCURING LIGHT FIXTURES, EXIT SIGNS AND LIGHTING CONTROL PANEL (LCP). VENDOR INFORMATION CAN BE FOUND ON SHEET A001. REFER TO SHEET A701 UNDER D5040 FOR WORK RESPONSIBILITY. B. COORDINATE EXACT FIXTURE LOCATIONS WITH ARCHITECTURAL CEILING PLAN. C. AFTER MERCHANDISE FIXTURES ARE IN PLACE, CLEAN AND AIM ALL LIGHT FIXTURES AS DIRECTED BY TENANT. D. COORDINATE PROPER DELIVERY OF ALL TENANT SUPPLIED LIGHTING ITEMS. E. TRACK LIGHT FIXTURES SHALL BE FURNISHED WITH 2 -FOOT, 4 -FOOT, 6 -FOOT, AND/OR 8 -FOOT LENGTHS, OUTLET BOX FEEDS, "L"/STRAIGHT FEED CONNECTORS, AND FLEXIBLE FEED CONNECTORS. F. ALL LIGHT FIXTURES TO BE UL AND NEC APPROVED. PROVIDE WIRING PER MANUFACTURER'S INSTALLATION DRAWING (TYP) SIGNALING LOOP �t SYNCHRONIZING MODULE FACP STOCK ROOM 2#12 AWG, 1#12 AWG GND, 3/4'C. - R -55 FA FIRE ALARM SYSTEM NOTES PROVIDE CONTROL MODULE FOR REQUIRED FUNCTION (TYPICAL). INITIATING/ CONTROL LOOP PROVIDE WIRING AND RELAY REQUIRED TO SHUTDOWN TENANT SOUND SYSTEM UPON FIRE ALARM ACTIVATION FIRE ALARM JUNCTION BOX BY LANDLORD. PROVIDE WIRING TO MAIN FIRE ALARM PANEL AS REQUIRED. 1. THIS DIAGRAM REPRESENTS A TYPICAL SYSTEM AND IS NOT INTENDED FOR INSTALLATION. SYSTEM SUPPLIER SHALL PROVIDE INSTALLATION DRAWINGS AND SCHEMATIC WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL BE COORDINATED WITH THE SYSTEM SUPPLIER. SYSTEM INSTALLER SHALL BE NICET CERTIFIED, IF REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 2. SYSTEM SUPPLIER SHALL SUPERVISE INSTALLATION, PROGRAM AND TEST SYSTEM AND INSTRUCT OWNER ON SYSTEM OPERATION. 3. ALL FIRE ALARM WIRING SHALL BE PLENUM RATED. EXPOSED FIRE ALARM WIRING, 10'-0" AFF AND BELOW, SHALL BE INSTALLED IN CONDUIT TO ABOVE ACCESSIBLE CEILING SPACE OR STRUCTURE. 4. ALL CONTROL CABINETS SHALL BE GROUNDED PER NEC REQUIREMENTS AND PER SPECIFICATIONS. 5. COORDINATE CITY TIE-IN REQUIREMENTS WITH LOCAL AUTHORITY. 6. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. REFER TO DRAWINGS FOR DEVICE QUANTITY AND LOCATIONS. 7. FIRE ALARM SYSTEM SHALL MATCH LANDLORD'S EXISTING FIRE ALARM SYSTEM. FOR TIE IN TO LL FA SYSTEM 1 ADDRESSABLE FIRE ALARM SYSTEM TYPICAL WIRING DIAGRAM E900 SCALE: NONE REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC APR 1 2 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER 0111 CLIENT RILEY ROSE 3880 N. MISSION ROAD LOS ANGELES, CA. 90031 PH: (213) 747-5100 FAX: (213) 747-5100 NOTES: THE DESIGNS SHOWN AND DESCRIBED HEREIN INCLUDING ALL TECHNICAL DRAWINGS, GRAPHICS AND MODELS THEREOF, ARE PROPRIETARY AND CANNOT BE COPIED OR COMMERCIALLY EXPLOITED, IN WHOLE OR IN PART, WITHOUT EXPRESS WRITTEN PERMISSION OF RILEY ROSE. THESE ARE AVAILABLE FOR LIMITED REVIEW AND EVALUATION BY CLIENTS, CONSULTANTS, CONTRACTORS, GOVERNMENT AGENCIES, VENDORS AND OTHER PERSONNEL ONLY IN ACCORDANCE WITH THIS NOTICE. COPYRIGHT © RILEY ROSE. 2018 ALL RIGHTS RESERVED. JOB NO: 4K1339 STORE NO: 5114 TENANT MALL LEVEL: LEVEL 1 ENGINEER 25760 First Street Cleveland, OH 44145 P 440 871 2410 F 440 871 7954 R20201B SUBMITTALS LANDLORD PRELIMINARY: 01.26.2018 PLAN CHECK: 03.09.2018 LANDLORD FINAL: 02.02.2018 ISSUE FOR BID: 03.15.2018 CONSTRUCTION SET: 00.00.0000 SHEET NAME ELECTRICAL SPECIFICATIONS & LUMINAIRE SCHEDULE DWN BY: EFO CHK BY: EJR SHEET NUMBER SCALE: NONE