Loading...
HomeMy WebLinkAboutPermit EL18-0338 - WALTERS RESIDENCE - SOLAR PV INSTALLATION. 16 SOLAR PANELS (4.72 KW) ON ROOFWALTERS RESIDENCE 13354 35 AVE S ELI 8-0338 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 7358600250 13354 35TH AVE S WALTERS RESIDENCE ELECTRICAL PERMIT Permit Number: EL18-0338 Issue Date: 5/16/2018 Permit Expires On: 11/12/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WALTERS TERRI K+ROBERTSON C 13354 35TH AVE S , TUKWILA, WA, 98168 DALE KRUEGER 1721 NE 64TH .AVE , VANCOUVER, WA, 98661 PRO -STAT ELECTRIC 1721 NE 64TH AVE, STE 120 , VANCOUVER, WA, 98661 PROSTE*890ON 111 Phone: (503) 539-7772 Phone: (360) 859-3749 Expiration Date: 9/15/2019 DESCRIPTION OF WORK: SOLAR PV INSTALLATION. 16 SOLAR PANELS (4.72 KW) ON ROOF OF RESIDENCE Valuation of single family: $2,000.00 Valuation of mf/comm: $0.00 Type of Work: ADDITION Fees Collected: $124.93 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-468: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: G/ / i� /��A�"�' J Date: -5- l� / a Print Name: 4(7 / $ w, J//, • "-I This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector, 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits, Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:f/www.TukwilaWA .gov Electrical Permit No. Project No. Date Application Accepted: 1161 \ tC6 Date Application Expires: (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 13354 35 Ave S Tukwila, WA 98168 King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: fl Yes Tenant Name: TERRI WALTERS PROPERTY OWNER Name: WALTERS, TERRI Address: 13354 35 Ave S Tukwila, WA 98168 City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: DALE KRUEGER Address: 1721 NE 64th AVE City: VANCOUVER State: WA Zip: 98661 Phone: (503) 539-7772 Fax: Email: dale.lcrueger@comcast.net ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: PROSTAT ELECTRIC Address: 1721 NE 64th AVE City: Vancouver State: WA Zip: 98661 Phone: (503) 539-7772 Fax: Contr Reg No,: PROSTE*8900N Exp Date: 07/20/2009 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 2,000 Scope of Work (please provide detailed information): SOLAR PV INSTALLATION. SOLAR PV INSTALLATION. 16 SOLAR PANELS (4.72kW) ON ROOF OF RESIDENCE. Will service be altered? 121 Yes 0 No Adding more than 50 amps? Cl Yes J No Type of Use: Type of work: O New ha Addition 0 Service Change 0 Remodel 0 Tenant Improvement O Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Property Served by: O Puget Sound Energy Seattle City Light WAPelmit Center \Applications -Handouts \Permit Applications d'DFalectrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) O Service change with added/altered circuits $83.54 1 number of added circuits $12.00 ea O Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 O Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea * * * FECTtIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED`5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUIL 1 ING 0 OR LECTRICAL CONTRACTOR: Signature: Print Name: DALE KRUEGER Date: 03/24/2018 Day Telephone: (503) 539-7772 Mailing Address: 1721 NE 64TH AVE VANCOUVER, WA 98661 City State Zip W:\Petmit CenteAApplicali-Handouts\Permit Applications \PDF's\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 b Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK 24.61 EL18-0338 Address: 13354 35TH AVE S Apn 7358600250 24.61 Credit Card Fee $0.72 Credit Card Fee R000.369.908.00.00 0.00 $0.72 ELECTRICAL $23.89 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14494 R000.345.832.00.00 0.00 $23.89 $24.61 Date Paid: Wednesday, May 16, 2018 Paid By: CHRIS WILLIAMS Pay Method: CREDIT CARD 016130 Printed: Wednesday, May 16, 2018 8:04 AM 1 of 1 CRWSYSTEMS DESCRIPTIONS ACCOUNT QUANTITY I PAID PermitTRAK $100.32 EL18-0338 Address: 13354 35TH AVE 5 n: 7358600250 $100.32 ELECTRICAL $95.54 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $95.54 TECHNOLOGY FEE $4.78 TECHNOLOGY FEE R000.322.900.04.00 0.00 $4.78 TOTAL FEES PAID BY RECEIPT: R14216 $100.32 Date Paid: Wednesday, April 11, 2018 Paid By: PRO -STAT SERVICES LLC Pay Method: CHECK 3504 Printed: Wednesday, April 11, 2018 10:58 AM 1 of 1 CRWYSTEMS INSPECTION NO, INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: / _ g,(1 Type of Inspection: h-- f� 1. Address: , - (,)35i 33 / , Date Called: Special In str ctions. f t pf 340 M. c)7 (( Date Wanted: t 7 16%11. Requester: Phone No: 713 l Approved per applicable codes. aCorrections required prior to approval. COMMENTS: Cv, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 03 CI. ca .0 -0 0 (D (Fa a?, 3 *-9, 0 CD 'V 5 0 3 < < CD cr, 0 a2 - 6 cr, LIJ0 0 13 -Tlcrn cx Z 0 OZ,..%fri cc PV Module PV Module S YC500 Micros 8 modules odules grounded per 690.43(C) with listed Sunmodo grounding YC500 Micros 8 modules ules grounded per 690.43(C) wit fisted Sunmodo grounding PV Module PV Module PV Module PV Module /6 Ground J Box Condutors= #10 AWG THHN in 3/4" EMT or FMC Ground # 8AWG Distance 40' Inverter Cable Black - L1 Red - L2 White- Neutral Green- round PV Module Module Ratings Manufacture: itek Model #: IT 295 Open -Circuit Voltage: 38.0V Operation Voltage: 30V Max String Voltage: 600V Operating Current: 8.2A Short -Circuit Current: 8.7A Max Series Fuse: 15A Maximum Power(STC): 295W VOC Temp Coeff: -.432%C PV Module /#6 Ground Breaker box with branch OCPDs 15A • M Inverter Specs: Manufacture: APSystems Module: YC5001 Max Output Current: 2.08A Nominal Output Volts: 240V Output Frequency: 59.3hz-60.5hZ Output Volt Range: 211V -264V Total number of Modules: 16 System Size: 4.72 kW SOLAR METER Utility meter on house Solar meter base on exterior of garage 125A Buss Existing Shop sub RECEIVED CITY OF TUKWILA APR irk 9 2018 PERMIT CENTER 25A Utility Meter 0 000 200A 1.1.1. 01)2)1 AC Point of Interconnection (NEC 690.54): Rated AC output: 16.64A (#of invertersX2.08A) Nominal AC Voltage: 240V )-) 60A REVIE' COMPLIANOE WITH NFPA 70 - NEC APR 17 2018 Job: Address: Walters City of Tukwila 13354211NaajanSIN Tukwila WA 98168 BRIMMA c=> Iar c z 0 c 0 Cn n r CD 3 CO m o v cD 5. o ca o o•� O Cfl 5'neJ 3 CO CO CD O w 0 CD O N — O 00. 0 0 —c co co 3 co� m CD 35th Ave S 0 CD v CD 0 c o 3 • o -o iv 3 O 'C7 0 • Cn N N (DD Cts -oo 0 o•oo z© Oce' m0 70 ncrn CDN sl3 CD o `< --1 o Z rrn cD ><2 o n Cl ao) • zm, co *C: c =a 7 17 CD (1) 0 v 0. Itek ENERGY SE SOLAR MODULES Design & Engineering Data GENERAL DATA Cel type • 60 high -efficiency monocrystaliine p -type cells • 6x10 cell matrix Solar Glass • Ultra -clear anti -reflective treatment • Tempered. with low iron content • Anti -glare prismatic subsurface texture Backsheet • Multi -layered • Engineered adhesion for maximum weather protection Frame • High-strength corrosion -resistant anodized aluminum • Compatible with standard racking, accommodating both top-down clamps and bottom -flange mountina Cable • 42" 90°C 12AWG PV wire Junction Box • 3 bypass diodes • 1000 VDC MC4 connectors Grounding • Certified for Wiley Electronics WEEBTF^ grounding clips • Eight standard grounding locations per module for reduced ground wire length QUALIFICATIONS UL listing UL 1703 Fire Rating Type 2 PID Free 96 + hours .,,1. Certified Made Intertekk in Washington ELECTRICAL DATA* 280 SE 285, 55 290 SE 295 SE 300 SE Maximum Power - t1.,.(Wp) Maximum Power Voltage - VMrr (V) Maximum Power Current - Iwr(A) Open Circuit Voltage - Wc(V) Short Circuit Current - I. (A) Module Efficiency 280 32.3 8.6 39.2 9.3 16.70% 285 32.4 8.7 39.3 9.4 16.99% 290 32.6 8.8 39 5 39J 9.5 9.6 17.29% 17.59% 295 32.8 8.9 300 32.9 9.0 39.8 9.7 17.89% NOTE: SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 79.5 mm [3.13 in] 100 mm [3.94 in] 27 mm [1.06 in] 101.5 mm [4 in] TYP 203 mm [8 in] 1 TYP Iter{ ENERGY Building Solar 1 Powering The Future MECHANICAL DATA Dimensions 1001 mm X l 675mm X 50mm Weight 43 lbs MAXIMUM RATINGS Operational Temperature -40...+ 90°C Maximum System Voltage 1000 VDC Design Load (UL 1703) up to 113 lbs/ft2 Maximum Load (UL 1703) Maximum Wind Load 551 kg/m2 (5400 Pa) 1 13lbs/ft2 Max Series Fuse Rating 1 5A Max Reverse Current 15A TEMPERATURE RATINGS Nominal Operating Cell Temperature (NOCT) 45.01°C Temperature Coefficient of P..r -0.39%/°C Temperature Coefficient of V« -0.29%/°C Temperature Coefficient of 1 » +0.04%/°C Temperature Coefficient of V••• -0.38%/°C "Electrical characteristics may vary within ±2% of the indicated values at Standard Test Conditions (STC): Irradiance of 1,000W/m2, AM 1.5 spectrum. cell temperature at 25'G. 9.5 mm 5 mm 0 (.375 in] 0 [.198 in] TYP TYP 178 mm [7 in] 127 mm [5 in] - n 1067mm [42 in] Junction Bax OINI Frame Depth: 50 mm [1.971n] 1219 mm [48 in] 9 [3 610 m • 124 in • 7 mm .28 in] VIEWED FOR PLIANCE WITH NFPA 70 - NEC APR 17 2018 City of Tukwila • •=� GILDING DIVISION! 1675 mm [65.94 in] V07.23.16 3886 Hammer Drive 1 Bellingham, Washington 98226 1 360.647.9531 1 emaii:info@itekenergy.com 1 www.itekenergy.com SLINM•aol3 For more Information: Sales 503-850-4633 quintero@sunmodo.com Rail Pak 4 www.sunmodo.com DETAIL A Dimensions: WE PART NUMBER DESCRIPTION QTY 1 Panel "" Not Provided 4 2 K10040-001 L EZ ROOF MOUNT KIT 8 3 A20015 -XXX TOTAL AL RAILS LENGTH (INCH) 332 4 K10002 -XXX END CLAMP KIT 4 5 6 K10001-001 K106374)1 MID CLAMP KT 1/4 AL RAIL SPLICE KIT 6 2 DETAIL Et DETAIL C 166" IEWED ruti PLIANC WITH NFPA 70 - f.APR 17 208 48.0 DETAIL D Length varies depending on panel choosen Array Length awarigamt City of Tukwila UILDING ISION MALTENERGY Fsystems POWER DIMENSIONS 8.7 (221mm) --j--REVIEWEDruh : C/OMPLIANCES WIT 0 m NEC 1=C- WI MG DIVISION APR 1.7 2018 Leading the Industry in Solar Microinverter Technology outpJt integratec microinverter ground • Single unit connects two solar modules • Integrated ground • Peak output power 548W • Individual MPPT for each module • PLC communication & free monitoring • Ideal for today's high output PV modules The APsystems YC500i with EnergyMaxTM is a grid -tied microinverter with intelligent networking and monitoring systems to ensure maximum efficiency. Highly dependable and cost effective, the YC500i with EnergyMaxTm is optimized to accommodate today's high output PV modules effectively with up to 548W output and dual MPPT. An integrated ground allows for rapid installation for installers who prefer trunk cable architecture. Half the inverters and half the installation time means real cost savings for residential and commercial customers. INPUT DATA (DC) MPPT Voltage Range Operation Voltage Range Maximum Input Voltage Startup Voltage Maximum Input Current OUTPUT DATA (AC) Nominal Output Voltage Peak Output Power Maximum Continuous Output Power Nominal Output Current Default Output Voltage Range Peak Output Current Nominal Output Frequency Default Output Frequency Range Maximum Units Per Branch EFFICIENCY Peak Efficiency CEC Weighted Efficiency Nominal MPPT Efficiency Night Power Consumption MECHANICAL DATA Operating Ambient Temperature Range Storage Temperature Range Dimensions (WxHxD) inches Dimensions (WxHxD) mm Weight AC Bus (trunk cable) Enclosure Rating Cooling FEATURES & COMPLIANCE Communication (Inverter to ECU) Emissions & Immunity (EMC) Compliance Safety Class Compliance Grid Connection Compliance Monitoring *The default AC output is 240V mode. Programmable to 208V mode. **Programmable per customer and utility requirements. All settings UL approved. 22-45V 16V -52V 55V 22V 12A X 2 208V* 548W 500W 2.4A 183V -229V** 2.63A 240V' 548W 500W 2.08A 211V -264V" 2.28A 60Hz 59.3Hz-60.5Hz** 6 for 20A Breaker 1 7 for 20A Breaker 95.5% 95% 99.5% 120mW -40°F to +149°F (-40°C to +65°C) -40°F to +185°F (-40°C to +85°C) 8.75" x 6.5" x 1.1" 221mm x 167mm x 29mm 5.5 lbs (2.5kg) 12AWG NEMA 6 Natural Convection - No Fans Power line Communication FCC PART 15, ANSI C63.4, ICES -003 UL1741 CSA C22.2 No.107.1-01 IEEE 1547 Via EMA Software Specifications subject to change without notice - please ensure you are using the most recent version found at APsystems.com 600 Ericksen Ave NE, Suite 200, Seattle, WA 98110 1 844.666.7035 1 APsystems.com 10.25.16 0 A// Rights Reserved 111 0 14 t 1 ALTENERGY POWER (;ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0338 DATE: 04/11/18 PROJECT NAME: WALTERS RESIDENCE SITE ADDRESS: 13354 35 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: (S=. ftwC Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator LI LI PRELIMINARY REVIEW: Not Applicable LI (no approval/review required) DATE: 04/12/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 05/10/18 1111 Approved with Conditions vi riDenied (corrections entered in Reviews) (ie: Zoning Issues) F Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PRO -STAT ELECTRIC Washington State Department of Labor & Industries I lowEspanol Contact Safety & Health Claims & Insurance iSearch L&I A-Z1n,icx I Ielp My Page 1 of 3 VVorkplace Rights Trades & Licensing PRO -STAT ELECTRIC Owner or tradesperson Principals KRUEGER, BRANDON, PARTNER/MEMBER Krueger, Dale, PARTNER/MEMBER Krueger, Brandon, AGENT Dong business as PRO -STAT ELECTRIC WA UB I No 602 951 624 Pare, -It company Pro -Stat Services LLC 1721 NE 64th Ave Ste 120 VANCOUVER, WA 98661 360-859-3749 CLARK County Business type Limited Liability Company Governing persons BRANDON KRUEGER BRANDON KRUEGER; License Verify the contractors active registration / Iicen Electrical Contractor License specialties GENERAL License !-Jo. PROSTE*8900N Effectivc; expiration 09/15/2011— 09/15/2019 Designated administrator Hagedorn, Garin J depending on trade) and any past violations. Active. Meets current requirements. Active. Meets current requirements. License type License no. Electrical Administrator HAGEDGJ914QE Bond Contractors Bonding & Insurance Co Bond account nc PI2413 $4,000.00 Received by L&I Effective date 10/05/2010 09/29/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Infraction no Satisfied °It Help us improve https://seeurelni.wa.gov/verify/Detail.aspx?UB1=602951624&LIC=PROSTE*8900N&SAW= 5/16/2018 PRO -STAT ELECTRIC EPHID00477 Issue date 02/04/2015 Violation city VANCOUVER Type of violation ELECTRICAL CITATION Description Improper use of a Class B work permit. Electrical installation is outside the scope of a Class B work permit, the class B work permit is not valid. (See also WAC 296-46B-900 and WAC296-46B-900(26), effective after 12/30/2008 see WAC 296-46B-901, and WAC 296-46B-908. Infraction no ECAML02125 Issue date 07/31/2013 Violation city VANCOUVER Type of violation ELECTRICAL CITATION Desr option t' Improper use of -a Class B work permit. Electrical installation is outside the scope of a Class B work permit, the class B work permit is not valid. (See also WAC 296-46B-901, and WAC 296-46B-908). Infraction no. EROBA00841 Iss.e date 03/05/2013 Violation city Vancouver Tyre of violation ). ELECTRICAL CITATION De:>cription Failing to obtain:or post an electrical/teleco::Tmunications work permit prior to beginning the electrical/telecaImunication installation or alteration as refnhenced in WAC 296-46B-900 (3)(6), effective F.tter 12/30/2008 see WAC 296- 46B-901. RCW/WAC 19.28.101 RCW Violation amount $250.00 Satisfied RCW/ WAC 19.28.101 RCW Violation amount $100.00 Satisfied ........................ RCW/WAC 19.28.101 RCW Violation amount $250.00 Workers' c=,mp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 200,997-00 Doing 'business as PRO -STAT SERVI „ES Estimated workers reported Quarter 1 of Year .018 "7 to 10 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Account is current. Public Worcs Strikes and Debarments Verify the contractcr is eligible to perform work on public works projects. Contractor Strike. .......................................... . No strikes have bean issued against this contractor. Contractors not a::owed to bid Page 2 of 3 Help us improve https://secure.lni. wa.gov/verify/Detail.aspx?UBI=602951624&LIC=PROSTE* 8900N&SAW= 5/16/2018