Loading...
HomeMy WebLinkAboutPermit EL18-0408 - FORT DENT - REPLACE HVAC UNITS AND CIRCUITSFORT DENT 6840 FORT DENT WAY ELI 8-0408 Parcel No: Address: C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL OTC PERMIT 2954900425 Permit Number: EL18-0408 6840 FORT DENT WAY Project Name: FORT DENT Issue Date: 5/2/2018 Permit Expires On: 10/29/2018 Owner: Name: JOHN C RADOVICH DEV CO Address: 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 Contact Person: Name: RACHELLE HARTLEY Address: 7717 DETROIT AVE SW , SEATTLE, WA, 98106 Contractor: Name: MACDONALD MILLER FAC SOL INC Address: 7717 DETROIT AVE SW , SEATTLE, WA, 98106 License No: MACDOMF972BF Lender: Name: Address: Phone: (206) 768-4130 Phone: (206) 763-9400 Expiration Date: 1/6/2019 DESCRIPTION OF WORK: DISCONNECT (2) EXISTING ROOFTOP HVAC UNITS AND REPLACE WITH (2) NEW "LIKE IN KIND" HVAC UNITS. (2) 480 VOLT, 150 AMP, 3 PHASE CIRCUITS. (2) 120 VOLT, 20 AMP, 1 PHASE CIRCUITS Valuation of single family: $0.00 Valuation of mf/comm: $13,367.00 Type of Work: TENANT IMP Fees Collected: $366.89 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construct' or the performance of work. I am authorized to sign and obtain this development permit and agree to th nditions attached to this permit. Signature. Date: Print Name/%4k/7-y '' S This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection.' PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF Community Development Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wvo.v.TukwilaWA.gov Electrical Pern Project No. Date Application Accepted: 11— 10-1 Date Application Expires: /0 30---10 (For office we only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Sitc Address: 840 FORT DENT WAY Tenant Name: FORT DENT PROPERTY OWNER Name: JCR DEVELOPMENT COMPANY Address: 2835 82ND AVESE City: PriacwiLA state: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: RFL LE HARTLEY Addle": 7707 DETROIT AVE SW City: sEATTLE state: WA Zip: 98106 Phone: (206) 768-4130 Fax: Email: RACHELLE.HARTLEY@MCAMILLER.% King Co Assessor's Tax No.: suite Number NONE Floor: ROOF New Tenant: 0 Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: MACONALD MILLER Addre": 7707 DEROIT AVE SW City: SEATTLE State: WA . • 98106 Phone: (253) 768-4130 Fax: (206) 768-4279 C°12tr Reg N11: MACDOMF975 ExP Date: 12/31/2018 Tukwila Business License No.; BUS -0994318 Valuation of Project (contractor's bid price): $ 13,367 Scope of Work (please provide detailed information): DISCONNECT (2) EXISTING ROOFTOP HVAC UNITS WITH (2) NEW "LIKE IN KIND" HVAC UNITS. (2) 480 VOLT, 150 AMP, 3 PHASE CIRCUITS (2) 120 VOLT, 20 AMP, 1 PHASE CIRCUTTS Will service be altered? 0 Yes IZJ No Adding more than 50 amps? 0 Yes IZJ No Type °fuse: COMMERCIAL HVAC IMILERIL O New 0 Addition 0 Service Change O Low Voltage 0 Generator 0 Fire Alann property Saved bv: gj Puget Sound Energy 0 Seattle City Light WAPennit CentenApplioetioni-HandouisTermlt ApplIcatioasTDPVEleettical Plonk Application Revised 1-1- tdocx Revised: hosay 2B17 • Remodel O Telecommunication O Tenant Improvement O Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) 1155.91 $83.54 ea 561.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 183.54 (no added/altered circuits) ❑ Service change with added/altered circuits 183.54 number of added circuits $ 12.00 ea ❑ Circuits added/altered without service change 155.69 (up to 5 circuits) ❑ Circuits added/altered without service change 155.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair 169.62 ❑ Low voltage systems 161.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 166.30 ❑ Temporary service (generator) 182.52 ❑ Manufactured/mobile home service 187.98 (excluding garage or outbuilding) ❑ Carnivals 182.21 Number of concessions 1 11.02�ea 111.02 ea Each ride and generator ***EN*rECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to pouible revision by the Permit Center to comply with current fee ached dee. Expiradon of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: RACHELLE HARTLEY Day Telephone: (206) 7684130 Date: 04/24/2018 Mailing Address: 7707 DETROIT AVE SW, SEATTLE, WA 98106 City sane z;e WArceinit o.M.Mypliata,sH.aoubWeamit AppUoetr.rWDFs\Eiectrial Permit Application Revised I-1-17.docx Revised: Jemmy 2017 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID 66. EL18-04 ress: 68; FORT DENT;' n• 2954900' ELECTRICAL 9.42 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $349.42 TECHNOLOGY FEE 17.4 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14400 R000.322.900.04.00 0.00 $17.47 $366.89 Date Paid: Wednesday, May 02, 2018 Paid By: MACDONALD MILLER FAC SOL INC Pay Method: CHECK 4812 Printed: Wednesday, May 02, 2018 12:53 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit 6F-ottoY: INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431- 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 6 A Project: 47- Ple-Ari Type of Inspection: diii.— Address: 6 Ftici h.," Nir.r. Date Called: Special Instructions: t4 t41.1.. - PC.,t0 c Date Wanted: , — a.m. p.m. Requester: Phone No: 31° 3 Viiiii; Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. MACDONALD MILLER FAC SOLdC O Washington State Department of Labor & Industries 0 Horne Espanol Contact Search L &I Safety & Health Claims & Insurance Page 1 of 3 SEARCH A -Z Index Help My 1.,&I Workplace Rights Trades & Licensing MACDONALD MILLER FAC SOL INC Owner or tradesperson Principals SIMONDS, DERRICK, PRESIDENT WEBSTER, MARK, VICE PRESIDENT Perry, Reagan, SECRETARY Gebhardt, Stephanie, TREASURER CT CORP SYSTEM, AGENT SIGMUND, FRED J, PRESIDENT (End: 02/11/2013) LOVELY, STEVE C, VICE PRESIDENT (End: 02/11/2013) KOPET, TYLER C, SECRETARY 7717 DETROIT AVE SW SEATTLE, WA 98106 206.763-9400 KING County License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. MACDOMF972BF Effective — expiration 01106/2003— 01/06/2019 Designated administrator Adams, Edward J License type Electrical Administrator Bond LIBERTY MUTUAL INS CO Bond account no 023006952 Active. Meets current requirements. License no ADAMSEJ916B2 $4,000.00 Received by L8.1 Effective date 01/08/2003 12/11/2002 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Help us improve httns://secureini.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOMF972BF&SAW= 5/2/2018 MACDONALD MILLER FAC SOLok-NC Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 706,276-00 Doing business as MACDONALD MILLER FACILITY Estimated workers reported N/A L&I account contact (360)902-4817 Track this contractor 0 SeH Insured. This business is certified to cover its own workers' comp costs. No premiums due. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects, Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/24/2015 Inspection no, 317936840 Location 14360 SE Eastgate Way Bellevue, WA 98007 Inspection results date 08/04/2015 Inspection no. 317937121 Location 530 Fairview Ave N Seattle, WA 98103 Inspection results date 06/18/2012 Inspection no. Violations No violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOMF972BF&SAW= 5/2/2018