HomeMy WebLinkAboutPermit EL18-0449 - SABEY - INSTALL READER BOARD, CARD READERS, DOOR CONTACTS, NETWORK CAMERAS, ETCSABEY
3355 S 120 PL BLDG 5
ELI 8-0449
Parcel No:
Address:
0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
ELECTRICAL OTC PERMIT
1023049082 Permit Number: EL18-0449
3355 S 120TH PL BLDG 5
Project Name: SABEY
Issue Date: 5/15/2018
Permit Expires On: 11/11/2018
Owner:
Name:
Address:
SABEY CORPORATION
12201 TUKWILA INTL BLVD 4TH FL ,
SEATTLE, WA, 98168
Contact Person:
Name: BURT MAXWELL Phone: (206) 963-3517
Address: 12500 AURORA AVE N , SEATTLE, WA,
98133
Contractor:
Name: COCHRAN INC (ELECTRICAL)
Address: PO BOX 33524 , SEATTLE, WA, 98133
License No: COCHRI*088JS
Lender:
Name:
Address:
1}/
Phone: (206) 367-1900
Expiration Date: 4/11/2020
DESCRIPTION OF WORK:
INSTALL (1) READER BOARD, (2) CARD READERS, (2) REQUEST TO EXIT, (4) DOOR CONTACTS, (2) NETWORK
CAMERAS. RUN ASSOCIATED CABLE TO IDF 239. PERFORM CONNECTIONS FOR (2) ELECTRICAL LOCKS. (13)
DEVICES. APPROX 1000 SF
Valuation of single family: $0.00
Valuation of mf/comm: $14,134.00
Type of Work: TENANT IMP
Fees Collected: $385.84
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
Permit Center Authorized Si gnature:fkM 1i
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
VI/115
Date:
2017
2017
2017
2015
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and a ree to the conditions attached to this permit.
Signature: Date: s'7i8
Print Name: e 1,7p 111
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***ELECTRICAL PERMIT CONDITIONS"`
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical
Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical
Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations,
Chapter 296-46B WAC and the Washington Cities Electrical Code.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts
of the building, such equipment shall not be concealed until it has been inspected and approved by the
Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any
violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related
documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work
permits. Where approved plans have been issued, revisions to the plans and additional review may be
required.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2100 ELECTRICAL FINAL
7003 ROUGH -IN ELECTRICAL
7002 SERVICE
7001 UNDERGROUND/SLAB
CITY OF TUKWIQ
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TulcwilaWA.gov
Electrical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
tf
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 3355 S 120TH ST TUKWILA, WA 98168 Suite Number.
New Tenant:
Tenant Name: SABEY (J# 512367)
PROPERTY OWNER
Name: BURT MAXWELL
Name: SABEY CONSTRUCTION
City: State: Zip:
Address: 3355 S 120TH ST
Email: KIM.ZINTER@COCHRANINC.COM
City: TUKWILA State: WA
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: BURT MAXWELL
Address:
City: State: Zip:
Phone: (206) 963-3517 Fax:
Email: KIM.ZINTER@COCHRANINC.COM
Floor:
El Yes .. No
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
COCHRAN INC.
Address: 12500 AURORA AVE N
City: SEATTLE State: WA Zip: 98133
Phone: (206) 963-3517 Fax:
Contr Reg No.:
COCHRI*088JS Exp Date:
Tukwila Business License No.;
Valuation of Project (contractor's bid price): $ 14,134
Scope of Work (please provide detailed information): INSTALL (1) READER BOARD, (2) CARD READERS
(2) REQUEST TO EXIT, (4) DOOR CONTACTS, (2) NETWORK CAMERAS. RUN ASSOCIATED
CABLES TO IDF 239. PERFORM CONNECTIOS FOR (2) ELECTRICL LOCKS. (13) DEVICES
APPROX 1000 SQ
Will service be altered? J Yes z No
Type of Use: SECURITY/LOW VOLTAGE
Type of work:
O New CI Addition
O Low Voltage 0 Generator
Prope y Served bv:
0 Puget Sound Energy El Seattle City Light
Adding more than 50 amps? ED Yes EJ No
O Service Change
O Fire Alarm
WAPermit CenterlApplications-1-landoutsl Permit Applications \PDFstElectrical Permit Application Revised 1-1-17.docx
Revised: January 2017
bh
O Remodel
O Telecommunication
O Tenant Improvement
O Temporary Service
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $155.91
(including an attached garage)
❑ Garages, pools, spas and outbuildings $83.54 ea
❑ Low voltage systems
(alarm, furnace thermostat) $61.05 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $83.54
(no added/altered circuits)
❑ Service change with added/altered circuits
number of added circuits
❑ Circuits added/altered without service change
(up to 5 circuits)
❑ Circuits added/altered without service change $55.69
(6 or more circuits) $7.65 ea
❑ Meter/mast repair $69.62
❑ Low voltage systems $61.05
(alarm, furnace thermostat)
$83.54
$12.00 ea
$55.69
MULTI -FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $66.30
❑ Temporary service (generator) $82.52
❑ Manufactured/mobile home service $87.98
(excluding garage or outbuilding)
❑ Carnivals $82.21
Number of concessions $11.02 ea
Each ride and generator truck $11.02 ea
***EFFECTIVE JANUARY 1, 2014 EACH
PERMIT WILL BE ASSESSED A 5%
TECHNOLOGY FEE* * *
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
tomty signed
try
Kiln TimerKim Zinter DN: e er59da53mp4fed.com, O.DAa Simplietl, CN.Gm Lnx
Date. 20f805,101l:sess-orcc 05/10/2018Signature:
Date:
Print Name: KIM ZINTER- COCHRAN INC. Day Telephone: (206) 963-3517
Mailing Address: 12500 AURORA AVE N SEATTLE, WA 98133
City
W:\Permit Center\Applications-Handouts\Permit Apptications \PDPs\Electrical Permit Application Revised 1-1-17.docx
Revised: January 2017
bh
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT QUANTITY
PAID
PermitTRAK
385.84
EL18-0449 Address: 3355 5120TH PL BLDG 5
Apn: 1023049082
385.
ELECTRICAL
$367.47
PERMIT FEE MULTI-FAM/COMM
R000.322.101.00.00
0.00
$367.47
TECHNOLOGY FEE
$18.37
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14492
R000.322.900.04.00
0.00
$18.37
$385.84
Date Paid: Tuesday, May 15, 2018
Paid By: COCHRAN INC (ELECTRICAL)
Pay Method: CHECK 14342
Printed: Tuesday, May 15, 2018 12:48 PM 1 of 1
CRWSYSTEMS
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36
Permit Inspection Request Line (206) 438-9350
Project: Ai
(e--
Type of Inspection:
Address:
3) --)-1121-
9___
--) i2.0 1
Date
Date Called:
Special Instructions:
Date Wanted:
7(q
Ca-mj.
P.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
OMMENTS:
Inspector:
Date:
F-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
COCHRAN INC
0 Washington State Department of
Labor & Industries
0
Safety & Health
Esi C'olltact
Claims & Insurance
[Search L&I
A -Z Index Help
Workplace Rights
COCHRAN INC
Owner or tradesperson
Principals
COCHRAN, ROBERT L
COCHRAN, GORDON W
COCHRAN-OLSEN, LEEANN G
COCHRAN, ROBERT L, AGENT
Doing business as
COCHRAN INC
WA UBI No
578 042 134
PO BOX 33524
SEATTLE, WA 98133-0524
206-367-1900
KING County
Business type
Corporation
Governing persons
RAE
BROWN
GORDON W COCHRAN;
ROBERT L COCHRAN,
DONNA J HEITMAN;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor Active.
Meets current requirements.
License spec alties
GENERAL
License no.
COCHRI*088JS
Effective — expiration
04/10/1992— 04/11/2020
Designated administrator
Heywood-cochran, Michael D
License type
Master Electrician
Bond
TRAVELERS CAS & SURETY CO
Bond account no.
081S103533100BCM
Received by L&I
01/08/2001
Savings
No savings accounts during the previous 6 year period.
Active.
Meets current requirements.
License no.
HEYWOMD901RF
$4,000.00
Effective date
04/09/2001
Expiration date
Until Canceled
Page 1 of 3
SEARCH
My 1.X1
Trades & Licensing
Help us improve
https://securelni.wa.gov/verify/Detail.aspx?UBI=5780421348LLIC=COCHRI*088JS&SAW= 5/15/2018
COCHRAN INC
License Violations
Infraction no
ERADJ00249
Issue date
11/05/2013
Violation city
SEATTLE
Type of violation
ELECTRICAL CITATION
Description
Employing an individual for the purposes of
chapter 19.28 RCW who does not possess a
valid certificate of competency or training
certificate to do electrical work.
Infraction no.
EJONV02771
Issue date
09/27/2012
Violation city
SEATTLE
Type of violation
ELECTRICAL CITATION
Description
Failing to obtain or post an
electrical/telecommunications work permit
prior to beginning the
electrical/telecommunication installation or
alteration as referenced in WAC 296-46B-900
(3)(6), effective after 12/30/2008 see WAC 296-
46B-901.
Infraction no.
EJONV02773
Issue date
09/27/2012
Violation city
SEATTLE
Type of violation
ELECTRICAL CITATION
Description
Failing to request an inspection within 3
business days after completion of the
installation or 1 business day after energizing,
whichever occurs first as referenced in WAC
296 -46B -900(10)(a), effective after 12/30/2008
see WAC 296 -46B -901(10)(a).
Satisfied
RCW/WAC
19.28.271 RCW
Violation amount
5250.00
Satisfied
RCW/WAC
19.28.101 RCW
Violation amount
52,000.00
Satisfied
RCW/WAC
19.28.101 RCW
Violation amount
5500.00
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workerscomp premiums.
This company has multiple workers' comp accounts.
Active accounts
L&I Account ID
194,860-01
Doing business as
COCHRAN ELECTRIC CO INC
Estimated workers reported
Quarter 1 of Year 2018 "Greater than 100 Workers"
L&I account contact
T3 / DAVID PRYOR (360)902-4804 - Email: PRYD235@lni.wa.gov
Track this contractor E.
Account is current.
Page 2 of 3
Help us improve
https://secureini.wa.goviverify/Detail.aspx?UBI=578042134&LIC=COCHRI*088JS&SAW= 5/15/2018
COCHRAN INC
Public Works Strikes and Deb ments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
No strikes have been issued against this contractor.
Contractors not allowed to bid
No debarments have been issued against this contractor.
Workplace safety and health
Check for any past safety and health violations found on jobsites this business was responsible for.
Inspection results date
06/07/2017
Inspection no.
317944877
Location
747 Broadway
Seattle, WA 98104
Inspection results date
03/30/2017
Inspection no.
317943983
Location
12500 Aurora Ave N
Seattle, WA 98133-0524
Inspection results date
06/09/2015
Inspection no
317935709
Location
15415 35 ave. s.w.
Lynnwood, WA 98087
Inspection results date
09/12/2014
Inspection no.
317407344
Location
3000 N.E.4 St.
Renton, WA 98056
Violations
No violations
No violations
Violations
Page 3 of 3
Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington.
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578042134&LIC=COCHRI*088JS&SAW= 5/15/2018