Loading...
HomeMy WebLinkAboutPermit EL18-0536 - FOSTER HIGH SCHOOL - UPGRADE SERVICE, POWER AND LIGHTING SYSTEM, RENOVATION TO ACADEMIC BUILDINGFOSTER HIGH SCHOOL 4242 S 144TH ST BLDG 1 Apn: 1523049108 FINALED 04/21/2021 ELI 8-0536 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1523049108 4242 S 144TH ST BLDG 1 Project Name: FOSTER HIGH SCHOOL ELECTRICAL PERMIT Permit Number: EL18-0536 Issue Date: 1/9/2019 Permit Expires On: 7/8/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 JEFF FEENEY Phone: (360) 352-8883 906 COLUMBIA ST SW, STE 400 , OLYMPIA, WA, 98501 TEKNON CORPORATION Phone: (425) 895-8535 10675 WILLOW RD NE SUITE 100 , REDMOND, WA, 98052 TEKNOC*06218 Expiration Date: 9/24/2020 11, DESCRIPTION OF WORK: UPGRADING THE EXISTING SERVICE FROM 1600A TO A 2500A SERVICE. PROVIDE COMPLETE POWER AND LIGHTING SYSTEM FOR THE CLASSROOM ADDITION AND RENOVATION OF THE EXISTING ACADEMIC BUILDING. PROVIDE ELECTRICAL CONNECTIONS TO SUPPORT THE FULL HVAC UPGRADE. Valuation of single family: $0.00 Valuation of mf/comm: $4,744,109.00 Type of Work: TENANT IMP Fees Collected: $38,181.08 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 'itAkt,t Permit Center Authorized Signature 1 V I Date: I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached togs permit. Signature: Print Name: 62 fiiIi tZcJ1 �U' 12 Date: 1 — 9 - 2 , 19 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Coltrnurni y Development Department Permit Center 6300 Southcenter Blvd.. Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Ci LI Project No. Date Application Accepted: Date Application Expires: (For oftee ELECTRICAL PERMIT APPLICATION Applications and plats must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4242 Scor 'l l4 -4t svefi Tenant Name: Fe Sr 'UAW 25C4teci-- PROPERTY OWNER Name: JiffFest-ie"? Name: Ira.. vitA Ni 4 (0 Address: 4io4 0 S. 14-4V siNeevr Phone: .35z.13t Fax: M/4 City:.0 ice. State: viA Zip: Qrei(08 CONTACT PERSON — person receiving all project conmunication Name: JiffFest-ie"? Address: torp Icol3 tilw,A. - i '61 iftaittO City: t a State: Wi Zip:9850i Phone: .35z.13t Fax: M/4 Ems;l:.'l fE''e fie knib -4Yrhi.ccn-, King Co Assessor's Tax No.: l5'-$04' i I c l- Suite Number: µ/A' Floor. N/A New Tenant: ❑ Yes ,No ELECTRICAL CONTRACTOR INFORMATION Company Name:II b Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Busineu License No.; Valuation of Project (contractor's bid price): S 4,744,109 Scope of Work (please provide detailed information): Electrical scope includes upgrading the existing Electric Service from 1600A to a 2500A Service. Provide complete power and lighting system for the classroom addition and renovation of the existing academic building. Provide electrical connections to support the full HVAC upgrade. Will service be altered? Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Tusk of work: ❑ New 0 Addition 0 Service Change 0 Remodel 0 Tenant Improvement ❑ Low Voltage 0 Generator 0 Fire Alarm 0 Telecommunication 0 Temporary Service Prone y Served by: ❑ Puget Sound Energy Seattle City Light W:Pmnt Cenmr•Appliwtionc-Fl+nMwnwa a AppliciW lmri vl ramt Applioaien Revised 1.1.17.duca Revised: loamy 2017 bit Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings 583.54 ea ❑ Low voltage systems (alarm, furnace thermostat) 561.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 583.54 (no added/altered circuits) ❑ Service change with added/altered circuits 583.54 number of added circuits 512.00 ea ❑ Circuits added/altered without service change 555.69 (up to 5 circuits) ❑ Circuits added/altered without service change 555.69 (6 or more circuits) 57.65 ea ❑ Meter/mast repair 569.62 ❑ Low voltage systems 561.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL. Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 566.30 ❑ Temporary service (generator) S82.52 ❑ Manufactured/mobile home service 587.98 (excluding garage or outbuilding) ❑ Carnivals 58221 Number of concessions 511.02 ea Each ride and generator truck S 11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: City Stir: Zip Date: Day Telephone: w:vamit c'mc6AppYc60.HalBwYamit Applica;aaarPtJraiEkariol Pam4 seri, d: Jamey 2017 66 Page 2 Of 2 t Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $30,838.56 EL18-0536 Address: 4242 S 144TH ST BLDG 1 Apn: 1523049108 $30,838.56 ELECTRICAL $29,370.06 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $29,370.06 TECHNOLOGY FEE $1,468.50 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16217 R000.322.900.04.00 0.00 $1,468.50 $30,838.56 Date Paid: Friday, December 21, 2018 Paid By: TUKWILA SCHOOL DISTRICT Pay Method: CHECK 98402 Printed: Friday, December 21, 2018 1:48 PM 1 of 1 SYSTEMS DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT Receipt Number R14689 QUANTITY $7,342.52 EL18-0536 Address: 4242 S TH ST BLDG 1 Apn: 1 04910 7,342.52 ELECTRICAL PLAN CHECK FEE 7,342.52 8000.345.832,00.00 0.00 $7,342.52 TOTAL FEES PAID BY RECEIPT: R14689 $7,342.52 111111011111111111111111111111.1010, Date Paid: Monday, June 11, 2018 Paid By: BLRB ARCHITECTS Pay Method: CHECK 13375 Printed: Monday, June 11, 2018 11:27 AM 1 of 1 airwys TEMS Permit Number: EL18-0536 Description: FOSTER HIGH SCHOOL Applied: 6/11/2018 Approved: 11/16/2018 Site Address: 4242 S 144TH ST BLDG 1 Issued: 1/9/2019 Finaled: 4/21/2021 City, State Zip Code:TUKWILA, WA 98168 Status: FINALED Parent Permit: Parent Project: Details: Applicant: FOSTER HIGH SCHOOL Owner: TUKWILA SCHOOL DISTRICT Contractor: TEKNON CORPORATION UPGRADING THE EXISTING SERVICE FROM 1600A TO A 2500A SERVICE. PROVIDE COMPLETE POWER AND LIGHTING SYSTEM FOR THE CLASSROOM ADDITION AND RENOVATION OF THE EXISTING ACADEMIC BUILDING, PROVIDE ELECTRICAL CONNECTIONS TO SUPPORT THE FULL HVAC UPGRADE. SCHEDULED DATE COMPLETED DATE LIST OF INSPECTIONS TYPE INSPECTOR RESULT REMARKS SERVICE Jim Benner Notes: UNDERGROUND SLAB Jim Benner Notes: ROUGH -IN ELECTRICAL Jim Benner 513536 Notes: 1/16/2019 AM 1/16/2019 SERVICE Jim Benner NOT APPROVED 302742 Notes: CORRECTIONS/ #1 -INSTALL 1 GROUND ROD EACH FOR OUTSIDE BUILDING -MISSING PANEL FILLERS AND K.O. SEALS CORRECTIONS/ #1 -INSTALL 1 GROUND ROD EACH FOR OUTSIDE BUILDING -MISSING PANEL FILLERS AND K.O. SEALS 3/15/2019 AM j 3/15/2019 UNDERGROUND SLAB Jim Benner1 PARTIAL APPROVAL 33641 Notes: PARTIAL APPROVAL/#2 O.K. -UG CONDUITS WITHIN FOOTPRINT OF GYM S.E. PARTIAL APPROVAL/#2 O.K. -UG CONDUITS WITHIN FOOTPRINT OF GYM S.E. Printed: Thursday, 14 October, 2021 1 of 10 '•A•1" r1 SUPERION Permit Inspections City of Tukwila 3/19/2019 AM 3/19/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 524910 Notes: PARTIAL APPROVAL/43 O.K. -SERVICE CONDUITS ALONG SOUTH SIDE PARTIAL APPROVAL/#3 O.K. -SERVICE CONDUITS ALONG SOUTH SIDE 3/27/2019 AM 3/27/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 473933 Notes: PARTIAL APPROVAL/#4 O.K. -SLAB CONDUITS AND STUBS IN GYM PARTIAL APPROVAL/#4 O.K. -SLAB CONDUITS AND STUBS IN GYM 5/16/2019 AM 5/16/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 391250 Notes: PARTIAL APPROVAL/#5 O.K. -5 x 2 1/2" NORTH SIDE FOR PORTABLES AND PANELS Ill & H2 PARTIAL APPROVAL/#5 O.K. -5 x 2 1/2" NORTH SIDE FOR PORTABLES AND PANELS HI & H2 5/22/2019 PM 5/23/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 82426 Notes: PARTIAL APPROVAL/#6 O.K. -UG CONDUITS AND STUBS AT SERVICE PAD SOUTH -CONTINUATION 0F4 x 2 1/2" NORTH, WEST TO BLDG. PARTIAL APPROVAL/#6 O.K. -UG CONDUITS AND STUBS AT SERVICE PAD SOUTH -CONTINUATION OF 4 x 2 1/2" NORTH, WEST TO BLDG. 6/3/2019 AM 6/3/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 214608 Notes: PARTIAL APPROVAL/#7 O.K. -XFMR SECONDARY SERVICE CONDUITS PARTIAL APPROVAL/#7 O.K. -XFMR SECONDARY SERVICE CONDUITS 6/26/2019 AM 6/26/2019 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 434143 Notes: PARTIAL APPROVAL/#8 O.K. -WALL COVER S.W. AS HIGHLIGHTED IN PINK PARTIAL APPROVAL/#8 O.K. -WALL COVER S.W. AS HIGHLIGHTED IN PINK Printed: Thursday, 14 October, 2021 2 of 10 r4 SUPERION Permit Inspections City of Tukwila. 7/3/2019 AM 7/3/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL 452544 Notes: INSPECTION PERFORMED 8Y ROGER CHICK WITH BHC CONSULTANTS PARTIAL APPROVAL SOUTH SIDE MECHANICAL AREA 5 -4' CONDUIT FEEDING GEAR 5 - 2 1/2 LOAD SIDE PVC ROUGH-IN PARTIAL 7/22/2019 AM 7/22/2019 ELECTRICAL Jim Benner APPROVAL 273544 Notes: PARTIAL APPROVAL/#9 O.K. -WAIL COVER AREA E ADMIN ROOM AND 2nd LEVEL -AREA 14st COVER EAST WALL AND ALL OTHER WALLS PARTIAL APPROVAL/#9 O.K. -WALL COVER AREA E ADMIN ROOM AND 2nd LEVEL -AREA J 1st COVER EAST WALL AND ALL OTHER WALLS 7/25/2019 AM 7/25/2019 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 152393 Notes: PARTIAL APPROVAL/#10 O.K. -WALL COVER ADMIN AREA PARTIAL APPROVAL/#10 O.K. -WALL COVER ADMIN AREA 7/25/2019 7/25/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#10 O.K. -SLAB CONDUITS AND WALL STUB AT. CHILLER PAD 7/29/2019 PM 7/29/2019 SERVICE Jim Benner PARTIAL APPROVAL 174762 Notes: PARTIAL APPROVAL/#11 O.K. -ENERGIZE SERVICE PARTIAL APPROVAL/#11 O.K. -ENERGIZE SERVICE 7/29/2019 7/29/2019 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#11 O.K. -5 x 3 1/2" FEEDER CONDUITS TO PICK UP OLD SERVICE CONDUITS PARTIAL APPROVAL/#11 O.K. -5 x 3 1/2" FEEDER CONDUITS TO PICK UP OLD SERVICE CONDUITS 8/7/2019 AM 8/7/2019 IN ELECTRILECTRICAL Jim Benner PARTIAL APPROVAL 333056 Notes: PARTIAL APPROVAL/#12 O.K. -WALL COVER RM 150 -INTERIOR WALLS 146, 147,148 Printed: Thursday, 14 October, 2021 3 of 10 r4 SUPERION 8/14/2019 8/14/2019 ROUGH -IN ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTION/ #13 -CORRIDOR S.E. REQUIRES SUPPORT OF EXISTING LV CABLING (304) CORRECTION/ #13 . -CORRIDOR S.E. REQUIRES SUPPORT OF EXISTING LV CABLING (304) ROUGH -IN PARTIAL 8/14/2019 AM 8/14/2019 ELECTRICAL Jim Benner APPROVAL 303397 Notes: PARTIAL APPROVAL/#13 O.K. -HARDLID 312C -WALLS 312A WEST, AREA C COMPLETE -CEILINGS 126, 127, 128 EXCEPT AT AREAS OF WALL WORK.317 & 319 PARTIAL APPROVAL/#13 O.K. -HARDLID 312C -WALLS 312A WEST, AREA C COMPLETE -CEILINGS 126, 127, 128 EXCEPT AT AREAS OF WALL WORK.317 & 319 ROUGH -IN PARTIAL 8/20/2019 AM 8/20/2019 ELECTRICAL Jim Benner APPROVAL 325459 Notes: PARTIAL APPROVAL/#14 O.K. -HARD LIDS 140B & 163 ROUGH -IN PARTIAL 8/22/2019 8/22/2019 ELECTRICAL Jim Benner APPROVAL Notes: PARTIAL APPROVAL/#15 O.K. -COVER CORRIDOR 304 EXCEPT SOUTH -COVER CEILING 128 -WALLS 313A PARTIAL APPROVAL/#15 O.K. -COVER CORRIDOR 304 EXCEPT SOUTH -COVER CEILING 128 -WALLS 313A 8/22/2019 8/22/2019 SERVICE Jim Benner NOT APPROVED Notes: CORRECTION/ #15 -XFMR. 2N GROUNDING TO BE DONE ON CAN W/ GEC AND LINE SIDE BONDING JUMPER TO XO CORRECTION/ #15 -XFMR. 2N GROUNDING TO BE DONE ON CAN W/ GEC AND LINE SIDE BONDING JUMPER TO XO ROUGH -IN 8/22/2019 8/22/2019 ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTION/ #15 -ADDITIONAL CONDUIT SUPPORT SOUTH CORRIDOR 304 Printed: Thursday, 14 October, 2021 4 of 10 sk SUPER1ON 8/22/2019 8/22/2019 SERVICE Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#15 O.K..-XFMR. 2A1 PRIMARY. AND SECONDARY -XFMR. 2N PRIMARY AND SECONDARY PARTIAL APPROVAL/#15 O.K. -XFMR. 2A1 PRIMARY AND SECONDARY -XFMR. 2N PRIMARY AND SECONDARY 8/29/2019 AM 8/29/2019 ROUGH -IN Jim Benner PARTIAL 224633 ELECTRICAL APPROVAL Notes: PARTIAL APPROVAL/#16 O.K. -CEILINGS AREA C COUNSELOR AREA ONLY -CEILING AREA E 1st FLOOR EXCEPT VP OFFICES W/ HIGH CEILINGS -XFMR P1A, PANEL H1, PANEL P1A PARTIAL APPROVAL/#16 O.K. -CEILINGS AREA C COUNSELOR AREA ONLY -CEILING AREA E 1st FLOOR EXCEPT VP OFFICES W/ HIGH CEILINGS -XFMR P1A, PANEL Hi PANEL P1A 8/29/2019 8/29/2019 ROUGH -IN ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTIONS/ #16 -TEMP. TUNNEL/CORRIDOR LIGHTING AND EM. LTG. TO BE WIRED BY CODE COMPLIANT WIRING MEANS -BROKEN/DAMAGED RECEPTACLES IN BAND ROOM317 TO BE REPAIRED OR REPLACED 9/4/2019 9/4/2019 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#17 O.K. -OCCUPY AREA C NOTE: -AREA E NOT READY PARTIAL APPROVAL/#17 O.K. -OCCUPY AREA C NOTE: -AREA E NOT READY 9/4/2019 AM 9/4/2019 ROUGH -IN ELECTRICAL Jim Benner CANCELLED 213090 Notes: CANCELLED -FINAL WANTED CANCELLED -FINAL WANTED 9/6/2019 AM 9/6/2019 ELECTRICAL Jim Benner CANCELLED 274687 Notes: CANCELLED -FINAL WANTED CANCELLED -FINAL WANTED Printed: Thursday, 14 October, 2021 5 of 10 SUPERION Permit Inspections City of 'Tukwila 9/6/2019 9/6/2019 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#18 O.K. -ELEVATOR MACHINE ROOM PANEL -ELEVATOR DISCO -AREA E . PARTIAL APPROVAL/#18 O.K. -ELEVATOR MACHINE ROOM PANEL -ELEVATOR DISCO -AREA E ROUGH -IN PARTIAL 9/10/2019 AM 9/10/2019 ELECTRICAL Jim Benner APPROVAL 12665 Notes: PARTIAL APPROVAL/#19 O.K. -CEILING COVER POTTERY PARTIAL APPROVAL/#19 O.K. -CEILING COVER POTTERY ROUGH -IN PARTIAL 11/7/2019 AM 11/7/2019 ELECTRICAL Jim Benner APPROVAL 521898 Notes: PARTIAL APPROVAL/#20 O.K. -EXTERIOR WALLS NORTH SIDE AREAA LEVELS 1 & 2 ROUGH -IN PARTIAL 11/21/2019 AM 11/21/2019 ELECTRICAL Jim Benner APPROVAL 56248 Notes: PARTIAL APPROVAL/#21 O.K. -INTERIOR WALLS NORTH CLASSROOMS 11 & 2 AREA A -WALLS AREA B LEVEL 1 -PANELS H2, P2A & P2B AND XFMR P2A ROUGH -IN PARTIAL 12/9/2019 AM 12/9/2019 ELECTRICAL Jim Benner APPROVAL 383231 Notes: PARTIAL APPROVAL/#22 O.K. -ALREADY APPROVED WALLS AREA B LEVEL 1 PARTIAL APPROVAL/#22 O.K. -ALREADY APPROVED WALLS AREA B LEVEL 1 ROUGH -IN 1/10/2020 1/10/2020 ELECTRICAL Jim Benner NOT APPROVED Notes: CORRECTION/ #23 -SUPPORT IN 12 MDF REQUIRED FOR EXISTING CABLES, CONDUITS, AND BOXES. ROUGH -IN PARTIAL 1/10/2020 AM 1/10/2020 ELECTRICAL Jim Benner APPROVAL 124762 Notes: PARTIAL APPROVAL/#23 O.K. -AREA B 12 WALLS AND HARDLIDS -AREA A L1 RESTROOMS Printed: Thursday, 14 October, 2021 6 of 10 r1 SUPERION 1/21/2020 AM 1/21/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 471004 Notes: PARTIAL APPROVAL/#24 O.K. -CLASSROOM CEILINGS L1 AREA A -HARDLID EAST EXIT PARTIAL APPROVAL/#24 O.K. -CIASSROOM CEILINGS L AREA A • -HARDLID EAST EXIT ROUGH -IN PARTIAL 1/28/2020 AM 1/28/2020 ELECTRICAL Jim Benner APPROVAL 555174 Notes: • PARTIAL APPROVAL/#25 O.K. -1.1 HARDLIDS N.W. EXIT AND UNDER EAST STAIRS AND N.E. EXIT -L2 AREA A CLASSROOMS CEILINGS PARTIAL APPROVAL/#25 O.K. -L1 HARDLIDS N.W. EXIT AND UNDER EAST STAIRS AND N.E. EXIT -L2 AREA A CLASSROOMS CEILINGS ROUGH -IN PARTIAL 3/13/2020 AM 3/13/2020 ELECTRICAL Jim Benner APPROVAL 10727 Notes: • PARTIAL APPROVAL/#26 O.K. -AREA A & B CEILINGS LEVELS 1 & 2 EXCEPT Ll CORRIDOR • PARTIAL APPROVAL/#26 O.K. -AREA.A & B CEILINGS LEVELS 1 & 2 EXCEPT L1 CORRIDOR ROUGH -IN PARTIAL 4/7/2020 AM 4/7/2020 ELECTRICAL Jim Benner APPROVAL 175704 Notes: PARTIAL APPROVAL/#27 O.K. -AREA B Li CEILING •-ALL AREA B CEILINGS PARTIAL APPROVAL/#27 O.K. -AREA B L1 CEILING -ALL AREA B CEILINGS ROUGH -IN PARTIAL 6/12/2020 AM 6/12/2020 ELECTRICAL Jim Benner APPROVAL 143959 Notes: PARTIAL APPROVAL/#28 O.K. -WALL COVER AREA F -AREA F SOUTH SOFFIT PARTIAL APPROVAL/#28 O.K. -WALL COVER AREA F -AREA F SOUTH SOFFIT ROUGH -IN PARTIAL 6/23/2020 AM 6/23/2020 ELECTRICAL Jim Benner APPROVAL 205807 Notes: PARTIAL APPROVAL/#29 0.K. -WALL COVER RMS. 227, 226, 225, 224, 223, 205 Printed: Thursday, 14 October, 2021 7 of 10 P-4 SUPERION Permit Inspections City of Tukwila 6/30/2020 AM 6/30/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 495438 Notes: PARTIAL APPROVAL/#30 O.K. -WALL COVER L2 AREA D WEST SIDE OF CORRIDOR 7/8/2020 AM 7/8/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 574449 Notes: PARTIAL APPROVAL/#31 O.K. -AREA F WOOD SLAT LIDS -COURTYARD ENTRY HARDLID -KITCHEN WALLS -L2 SECURITY ROOM WALLS -MAIN ENTRY SOFFIT WALL 7/14/2020 7/14/2020 UNDERGROUND SLAB Jim Benner PARTIAL APPROVAL Notes: PARTIAL APPROVAL/#32 O.K. -EXT. LTG. CONDUITS AND POLE BASES NORTH 7/14/2020 AM 7/14/2020 IN ELECTRILECTRICAL Jim Benner PARTIAL APPROVAL 483102 Notes: PARTIAL APPROVAL/#32 O.K. -LIBRARY WALLS AND HARD LIDS -WALLS IN 3 CLASSROOMS WEST OF LIBRARY {242, 43, 44?} PARTIAL APPROVAL/#32 O.K. -LIBRARY WALLS AND HARD LIDS -WALLS IN 3 CLASSROOMS WEST OF LIBRARY (242, 43, 44?) 7/22/2020 AM 7/22/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 352412 Notes: PARTIAL APPROVAL/#33 O.K. -WALL COVER COMPLETE PARTIAL APPROVAL/#33 O.K. -WALL COVER COMPLETE 8/7/2020 AM 8/7/2020 ROUGH IN ELECTRICAL Jim Benner PARTIAL APPROVAL 575592 Notes: PARTIAL APPROVAL/#34 O.K. -CEILING COVER L2 AREA C PARTIAL APPROVAL/#34 O.K. -CEILING COVER L2 AREA C 8/13/2020 AM 8/13/2020 IN ELECTRILECTRICAL Jim Benner PARTIAL APPROVAL 374141 Notes: PARTIAL APPROVAL/#35 " O.K. -CEILING l2 AREA D WEST AND KITCHEN/SERVERY EXCEPT 337E PARTIAL APPROVAL/#35 O.K. -CEILING L2 AREA D WEST AND KITCHEN/SERVERY EXCEPT337B Printed: Thursday, 14 October, 2021 8 of 10 it SUPERION 8/21/2020 AM 8/21/2020 ROUGH -IN ELECTRICAL Jim Benner PARTIAL APPROVAL 212219 Notes: PARTIAL APPROVAL/#36 O.K. -CEILINGS AREAS C & D L2 COMPLETE EXCEPT RM. 246 -CEILING ROOM 305 . PARTIAL APPROVAL/#36 O.K. -CEILINGS AREAS C & D L2 COMPLETE EXCEPT RM. 246 -CEILING ROOM 305 ROUGH -IN PARTIAL 8/28/2020 AM 8/31/2020 ELECTRICAL Jim Benner APPROVAL 0637 Notes: PARTIAL APPROVAL/#37 O.K. -CEILING COVER 246, 120, 121, 122, CORR. 115 9/3/2020 9/3/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED Notes: CORRECTIONS/ #38 -BLANK COVERS THROUGHOUT t2 AREAS C & D -PANELS SCHEDS AND LABELS -LABEL HWT AND LOCKOUT HASP -GFCI BATHROOMS ROUGH -IN PARTIAL 9/3/2020 AM 9/3/2020 ELECTRICAL Jim Benner APPROVAL 51436 Notes: PARTIAL APPROVAL/#38 O.K. -CEIUNG Ll AREA D ROUGH -IN PARTIAL 9/16/2020 AM 9/16/2020 ELECTRICAL Jim Benner APPROVAL 513536 Notes: PARTIAL APPROVAL/#39 O.K. -CEILING CORRIDOR 114 PARTIAL 9/16/2020 9/16/2020 ELECTRICAL FINAL Jim Benner APPROVAL Notes: PARTIAL APPROVAL/#39 O.K. -INVERTERS AND MANUAL XFER SWITCHES -PANEL 4X PARTIAL 9/23/2020 PM 9/23/2020 ELECTRICAL FINAL Jim Benner APPROVAL 392736 Notes: PARTIAL APPROVAL/#40 O.K. -FINAL B, C, D 9/23/2020 9/23/2020 I ROUGH -IN Jim Benner 1 1 PARTIAL 513536 I ELECTRICAL APPROVAL Notes: PARTIAL APPROVAL/#40 O.K. -CEILING COVER 126, 127, 12 Printed: Thursday, 14 October, 2021 9 of 10 N°••• p-1 SUPERION Permit Inspections City of Tukwila 9/23/2020 1---2.02(---) ELECTRICAL FINAL Jim Benner NOT APPROVED 392736 Notes: CORRECTIONS/ #40 -AREA B L2 ELECTRICAL ROOM LABEL 150 KVA XFMR AND FEEDER BREAKER AND Ll -PANEL SCHEDULES ELECTRICAL ROOM AREA B Ll 9/25/2020 9/25/2020 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL 392736 Notes: PARTIAL APPROVAL 4 O.K. -AREAS E & F 9/25/2020 9/25/2020 ELECTRICAL FINAL Jim Benner NOT APPROVED 392736 Notes: CORRECTION/ #41 -KITCHEN HOOD INTERLOCK•TO BE COMPLETED. 10/30/2020 AM 10/30/2020 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL 425-387-6333 Notes: PARTIAL APPROVAL/#42 CORRECTIONS MADE O.K. -TO OCCUPY NOTES: -CHILLER HOUSE REQUIRES FAS APPROVAL FROM L&I -LABELS AT SERVICE NOTING LOCATIONS OF EM. POWER 11/5/2020 AM 11/5/2020 ELECTRICAL FINAL Jim Benner PARTIAL APPROVAL 425-387-6333 Notes: 'PARTIAL APPROVAL/#43 O.K. -LABELS COMPLETE 4/21/2021 4/21/2021 ELECTRICAL ANAL Jim Benner APPROVED 425-387-6333 Notes: APPROVED/ #44 O.K. -FINAL Printed: Thursday, 14 October, 2021 10 of 10 S UPE R ION f PANIC 4D 526117 TO 8/4/17 r'"; Pim IAPKWC 55.7. 47 7 SIN: 72588 -SR-3 -AC Currant to Details Readings Semple Rate 6716/6716 900 1 Channels Number Description 1 AC Current AMPROBE 2 AC Current AMPROBE 3 ACCurrent AMPROBE Start Tine End Time 5/2612017 12:20:03 PM 8/4/201711:05:03 AM Cure Maximum Mean Minimum Range Sld Deviation 62.15 28.56 0.00 6215 19 49 64.18 25.32 0.00 64.18 14.41 43.26 15.17 0.00 43.26 12.07 I 6,2%1117 126X0 FAA cyimr 120740 Pu 6212017 umm PIA 612(2.7 120,12 Pu J 711 MOW PN i i 111 REVIEWED FOP COMPLIANCE WITH NPPA 70 - NEC NOV 15 2018 City 0 skw a 3UILDIN DIVISI * N nu%x17 12101 PuMAO PIA 142/2417 — A g 3 D CIT O TUKWILA 53. /5 kVA JUN 1 1 2018 PERMIT CENTER W2017 t19SA}AN On° trif1/4 PAWL 41)1�,4DZ 18.11 16.13- 14.16, 12.18. 10.21. 823 626. 428. 033 Phase Foster M$ ATS Epsting Emergency System Phase 8 Phase -1.651 1/26(2017 521:15 PM IN: 97811- SRP -3 & SRP -7 32K 0-5V its Readings Sample Rale Start Time End Time 4592/4592 900 1/26/2017 5:21:15 PM 3/15/2017 2:06:15 PM © Channels Number Description Line Maximum Mean Minimum Range Std Deviation 1 PhaseA 16.46 15.00 0.00 16.46 1.83 3 Phase B 12.27 9.90 0.00 1227 1.24 Phase C 7.79 6.83 0.00 7.79 0.87 1/31/2017 5.9090 PM 2/51/017 5:00:90 PM 2/1012017 5.90:00 PM 2/15/2017 690.00851 7 4/25,2017 590.00 PM REVIEWEDE W WITH COMPLIANCE 70 - NEC NOV 15 2018 3/2111017 59000 PM 3/2401? 80300 PM 414 a gag = 13. of itInct OF TUKWILA ( JUN 1 1 2018 E/e0115(54 BUILDING DIVISION! FXima'6 flr5 (4)( 4 z)() PERMIT CENTER 3215(2017 206:15 PM 59. 5VA TRANSFORMER Te (PANEL. 2K) 526117 TO 814/11 iV3 SVA S/N: 97706 - SRP -3 R SRP -7 32K 0-5V 7 Details Readings Sample Rate Start Tine End Time 6715/6715 900 5126/201712:17:44 PM 3/4/201710:47:44 AM C Channels Number Description Line Maximum Mean Minimum Range Std Deviation 1 5 Volt 43.91 0.00 43.91 5.01 3 5 Volt 48.04 4 6. 6.52 0.00 48.04 5.66 5 5 Volt 58.49 10.33 0.00 58.49 6.48 81 .514 N6N17 121744 PN 64/!717 125090 PA 6.1109 4142047 PO -WV 6022731 120200 FN 124044)P1.1 42120714.4 12N.d]PN 1/057 ✓d117 12:OP.WFM m 117I4PN REVIEWED .FOR COMPLIANCE ITH NFPA NOV 15 2018 7/214011142151 12X40 PN 1142.07 PN RECE1 /E• CITY QF TUKVVVA 4111i(45 JUN112018 PERMIT CENTER v A Z '/ 2'42517 1CA744 AM 31.41 2176 am Av A PANEL 464 526117 TO 8/4/17 P. 2 Statistics Date Table 1 S/N:97809-SRP-3& SRF-732KO Details Readings Sample Rate Start Tine 7164{7164 900 61 Channels Number Description 1 Phase 3 Phase B Phsce C 5/21{2017 8:14:52 PM Line Maximum 36.05 43.53 9 End Time 8/4{2017 10:59:52 AM Mean Minimum Runge Std Deviation 13.32 0.00 35.05 4.64 15.40 0.00 43.53 5.78 15.58 0.00 30.19 5.10 X21/2207 4:34:2211? L74'2017 AZ97 PM 6b*i?7 L.4R0A73 63Y.fi7 L. -WO PN 6*1U311 COMM 6326*3n axm PM REVIEWED I0H C0� P70C f�UE WITH NOV 15 2018 City of Tukwila BUILDING DIVISION 7163017 73212017 *113*Ali ntixn 840-..% PA* RECEiVEUPE- 43.53 X13) UM CITY OF TUKWILA 3v.4 @ vv13O JUN 1 1 2018 _ 106.5T to PERMIT CENTER 6*203? 109.12AM Na. PANEL 4E 5126/1710 814/17 fa..13 Ave C 52.V I KT? 2331 96. 94S 1 433 5,192911 1216 1 1 SiN: 96890 - SRP -3 & SRP -7 3( 0-5V 61 Details Readings Sample Rote Start Time End Time 671616716 900 5/26/2017 12:16:56 PM 814/2017 11:01:56AM ' E Channels Number Description Line Maximum 1187emen 0.00 37.37 Range Std Deviation Phase A 37.87 27.11 0.00 1 Phase B 37.87 10.26 3 Ph5se C 61.53 19.67 0.00 61.53 16.69 5 38 65 38.65 10.65 612011 120740Pu, 1l034/RA 6135:1V 334/31 833 6210317 234/4/833 (Mall 323333833 MOO 12334/833 REVIEWED .FON COMPLIANCE WITH NFPA 70 - NEC NOV 1 5 2018 City of Tulcwila BUILDING DIVISIO 317 WM Kg 74 ti2017 120)101M Tr2A117 12334/133 Pini<3&SA ?et/ RECEIVFD3Z. ILkVA CITY OF TUKWILA JUN 1 1 2018 PERMIT CENTER 333017 - MOOT7 734131833 1 UTILITY Vs: 240 V 23100 A 800A -P 600-1C-THW-P 178 Feet MPH: 2 PORT 1/2 Vs: 240 V 2355.16 A 200A -PORT 1/2 3/0-1C-THW-P 64 Feel 9/PH: 1 VPORT 3/4 V9: 240 V 2343968 200A -PORT 3/4 3/0-1C-THW-P 136 Feet 8/PH: 1 VPORT 516 Vs: 240 V 2393 A 200A -PORT 5/6 3/0-1C-THW-P 41 Feel 9/PH: 1 200A -PORT 7/8 3/0-1C,THWP 136 Feet #/PH: 1 PANEL V' Vs: 240 V 7848.65 A NINA bce engineers, inc. p:(253) 922-0446 f: (253) 922-0896 8021 12th 0881, 88110 200. tacoma, wa 98424 PORT 7/8 VA 240 V 2243.98 A REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 5 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 1 2018 PERMIT CENTER (Foster HS - Portables) FAULT ANALYSIS EDSA Paladin Designbase 6.0 DRAWN 3Y:(KK) FROJE_CT#: 215-101 DATE: 607/2.7,1P UB LL: FU AL AIC -E1 ("\ Paladin 1A-4nBase 3 -Phase Short Circuit v7.00.00 Project No. : 217-128 Project Name: Title Drawing No. : Revision No.: Jobfile Name: FOSTER HIGH SCHOOL Scenario : 1 : Page : 1 Date : 06/07/2018 Time : 10:51:59 am Company : Engineer: Check by: Case : 1 : Base Sumner HS System Summary Base MVA System Frequency(Hz) # of Total. Buses # of Active Buses # of Total Branches # of Active Sources # of Active Motors # of Active Shunts # of Transformers Reference Temperature(°C) Impedance Displaying Temperature(°C) 100.000 60 78 78 77 1 0 0 11 20.0 25.0 Calculation Options Calculating All or Multi -Buses Faults with Fault Z = 0.00000 + j 0.00000 Ohms Fault Phases: Phase A for Line -Ground Fault Phase B,C for Line -Line or Line -Line -Ground Fault Classical Calculation: Complex Z for X/R and Fault Current Transformer Phase Shift is not considered. Generator and Motor X/R is constant. Base Voltages : Adjusted by Tap/Turn Ratio Prefault Voltages : Use System Voltages REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC NOV 1 5 2018 City of Tukwila BUILDING DIVISION HiG4 cAttt Vu1Wyd6 Aic ciuuticriai RECEIVED CITY OF TUKWILA JUN 1 1 2018 PERMIT CENTER o WM() TOPME CP I NGS A1G Cita Paladin DesignBase 1 -Phase Short Circuit v5.10.00 Project No.: 216-101 Page • . 1 Project Name: Date • . 06/07/18 Title . Time : 03:40:48pm Drawing No.: Company : Revision No.: Engineer : JobFile Name: 216-101 Check by : Scenario . 1: CheckDate: Base kVA 100000 Cyc/Sec : 60 flLfzz System Information Total Number of Nodes Entered: 6 Total Number of Nodes: 6 Total Number of Branches: 5 Number of Active Sources: 1 Number of Inactive Sources: 0 Number of Active Motors: 0 Number of Inactive Motors: 0 Number of Transformers: 0 Number of Feeders: 5 Number of Control Devices: 0 Number of Reactors: 0 Number of Open Switches: 0 Number of Islands: 1 Z Displaying Temperature (C): 25.0 Matrix Size: Options 21 Elements 168 Bytes Classical Calculation Complex Z for X/R and Fault Current Generator and Motor X/R is constant Transfer 3P Network Data Calculated in Classical Methodology. Use Nominal Voltages REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 5 2018 City of Tukwila BUILDING RECEIVED CITY OF TUKWILA JUN 1 1 2018 PERMIT CENTER WV% 0 0 Paladin DesignBase 1 -Phase Short Circuit v5.10.00 Project No.: 216-101 Page : 2 Project Name: Date : 06/07/18 Title Time : 03:40:48pm Drawing No.: Company : Revision No.: Engineer : JobFile Name: 216-101 Check by : Scenario 1: CheckDate: Base kVA 100000 Cyc/Sec : 60 Bus Name Bus Results: at 0.5 Cycle Thevenin Imped. Pre -Flt X/R DC -Comp AC -Comp Asym V R(pu) X(pu) Ratio A A A PANEL 'P 240 19.4093 50.9008 2.6225 3265 7649 8316 PORT 1/2 240 135.969 113.189 0.8325 76 2355 2356 PORT 3/4 240 143.856 117.404 0.8161 68 2244 2245 PORT 5/6 240 133.449 111.843 0.8381 80 2393 2394 PORT 7/8 240 143.856 117.404 0.8161 68 2244 2245 UTILITY 240 0.9008 18.0150 20.0000 27920 23100 36237 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 5 2018 City of Tukwila BUILDING DIVISION Jobfile Name: FOSTER HIGH SCHOOL Bus Name Page : 2 Bus Results: 0.5 Cycle --Symmetrical Thevenin Imped. Complex Pre -Flt 3P Flt. LL Flt. LG Flt. LLG Flt V A A A A Z+(pu) Zo(pu) 3P X/R 2H1 208 11004 9800 12432 11927 25.2250 17.9338 3.6171 ATS 480 11759 10660 10842 12270 10.2286 13.9031 0.7966 INVERTER EL1 480 15352 14400 13746 15785 7.8350 11.8258 1.4860 INVERTER EL2 480 5548 4902 4496 5496 21.6801 38.1498 0.7044 NEW MDB 480 22457 22435 22407 23286 5.3561 6.8180 18.665 PANEL 2A1 208 4412 3857 4716 4588 62.9154 51.9319 1.3720 PANEL 2A2 208 4348 3801 4608 4494 63.8435 54.2100 1.3688 PANEL 2A3 208 4285 3746 4505 4404 64.7716 56.4892 1.3657 PANEL 2C1 208 5547 4869 5822 5740 50.0442 44.2895 2.3639 PANEL 2C2 208 5459 4791 5689 5605 50.8425 46.0308 2.3543 PANEL 2C3 208 5375 4716 5562 5476 51.6408 47.7829 2.3451 PANEL 2D 208 2015 1751 2044 2033 137.728 132.891 0.7693 PANEL 2E1 208 2816 2451 2938 2880 98.5777 87.3309 0.9391 PANEL 2E2 208 2762 2404 2862 2818 100.483 91.0381 0.9255 PANEL 2H2 208 10401 9246 11309 10894 26.6858 21.6376 3.1076 PANEL 2K1 208 6112 5374 6082 6185 45.4133 47.4920 2.7556 PANEL 2K2 208 6038 5308 5971 6095 45.9697 48.9263 2.6749 PANEL 2K3 208 4150 3625 3692 4007 66.8840 92.9548 1.2483 PANEL 2SA 208 698 606 701 703 397.676 394.421 4.3060 PANEL 2SB 208 292 253 283 296 950.627 1045.35 0.4964 PANEL 2X 208 701 608 707 712 395.857 387.336 4.8189 PANEL 4A 480 8021 7229 6067 7671 14.9963 30.6834 1.3474 PANEL 48 480 7977 7188 6030 7629 15.0780 30.8764 1.3429 PANEL 4C 480 9996 9124 7767 9619 12.0324 23.6276 1.5793 PANEL 4D1 480 18036 17383 16399 18380 6.6689 10.0203 2.7003 PANEL 4D2 480 19150 18680 17748 19494 6.2810 9.1851 5.0971 PANEL 4E 480 9532 8673 7357 9158 12.6189 25.0344 1.5196 PANEL 4F 480 5509 4853 4647 5611 21.8321 35.5015 0.5574 PANEL 481 480 15126 14295 12819 14971 7.9521 13.5764 2.3579 PANEL 482 480 14989 14151 12670 14829 8.0245 13.7578 2.3163 PANEL 4X 480 7099 6269 6510 7372 16.9433 22.5840 0.4794 PANEL C 208 4904 4282 4441 4882 56.5997 75.5459 0.7623 PANEL ELV 208 1568 1361 1402 1575 177.005 243.091 0.4877 PANEL H1 480 15305 14525 13179 15284 7.8589 13.0621 3.1639 PANEL 82 480 9970 9153 8042 10010 12.0637 22.3876 2.9275 PANEL H3 480 9587 8780 7688 9611 12.5467 23.5135 2.8679 PANEL L1 480 17941 17295 16243 18188 6.7042 10.1694 2.8882 PANEL L2 480 7778 6998 5880 7448 15.4643 31.6308 1.2955 PANEL P1A 208 4060 3546 4204 4168 68.3640 62.5314 1.1922 PANEL P18 208 3982 3476 4085 4062 69.7107 65.5988 1.1766 PANEL P2A 208 5973 5252 6562 6305 46.4676 35.3480 3.6687 PANEL P2B 208 5875 5164 6400 6188 47.2491 37.0053 3.6144 REVIEWED► r -Or COMPLIANCE WITH NEPA 70 - NPC NnV 15 2018 City of Tukwila BUILDING DIVI5Ig Jobfile Name: FOSTER HIGH SCHOOL Bus Name (1 (1 \-J `- l Page : 3 Bus Results: 0.5 Cycle --Symmetrical Thevenin Imped. Complex Pre -Flt 3P Fit. LL Flt. LG Flt. LLG Flt V A A A A Z+(pu) Zo(pu) 3P X/R PANEL P3A PANEL P3B PANEL S PANEL S1 PANEL S2 PANEL S3 PANEL S4 PANEL S5 PANEL S6 PANEL S7 PANLE 2N PRI PRI T -2D PRI T -2E PRI T -2K PRI T-2SA PRI T -4A PRI T -4H1 PRI T -4X PRI T-P1A PRI T-P2A PRI T-P3A SCL TRANSFORMER SDB1 SDB2 SEC SEC T -2D SEC T -2E1 SEC T -2K SEC T-2SA SEC T -4A SEC T -4H1 SEC T -4X SEC T-P1A SEC T-P2A SEC T-P3A 208 5883 5171 6469 6209 47.1795 35.7602 3.6163 208 5787 5086 6311 6104 47.9617 37.4230 3.5650 208 9806 8695 10402 10133 28.3072 24.7637 2.1525 480 6722 5989 5474 6486 17.8946 31.1620 0.9202 480 4655 4091 3944 4605 25.8395 40.8332 0.5713 480 3092 2698 2721 3113 38.8954 56.0027 0.3817 480 6544 5846 5040 6198 18.3802 35.9648 1.1889 208 2872 2498 2815 2874 96.6481 103.328 0.6169 208 1949 1691 1883 1965 142.442 158.357 0.4139 208 1296 1123 1244 1316 214.245 242.315 0.2921 208 2572 2238 2213 2509 107.927 161.963 0.8880 480 9420 8569 7254 9021 12.7682 25.4317 1.5510 480 16065 15160 14530 16532 7.4872 11.1205 1.6187 480 8558. 7720 6671 8317 14.0545 27.1612 1.1924 480 18004 17415 16267 18192 6.6808 10.2299 4.1933 480 10350 9293 9559 10795 11.6217 15.5421 0.6742 480 7493 6731 5636 7167 16.0521 33.1038 1.2755 480 14891 14052 12568 14708 8.0773 13.8846 2.3263 480 6331 5572 5830 6577 18.9976 24.9335 0.4290 480 14833 14021 12646 14689 8.1090 13.6922 2.8055 480 9838 9024 7910 9861 12.2264 22.8116 2.8779 480 9433 8631 7536 9440 12.7506 24.0444 2.8117 480 22600 22600 22600 23430 5.3222 6.7483 20.000 480 20556 20266 19790 21267 5.8515 7.9609 9.0804 480 16857 16193 15104 17210 7.1354 11.0641 4.6013 208 6094 5358 6774 6657 45.5519 33.3101 2.9437 208 2046 1778 2087 2074 135.652 128.668 0.7741 208 2900 2525 3059 2992 95.7299 81.7705 0.9608 208 6941 6118 7442 7215 39.9910 33.3101 4.1903 208 708 614 714 715 392.064 384.049 5.5406 208 4670 4085 5170 4995 59.4359 43.4011 1.3850 208 11269 10044 12908 12457 24.6307 16.6766 3.7226 208 704 610 711 716 394.502 384.049 4.9939 208 4142 3618 4330 4280 67.0204 59.4643 1.2087 208 6102 5366 6776 6540 45.4917 33.3101 3.7415 208 6033 5305 6720 6486 46.0075 33.3101 3.6993 REVIESCE WITH !. COMPLIANCE 70 - NEC NOV 1.5 2018 City of Tukwila BUILDING DIVISION / City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director November 19, 2018 John Wegener BLRB Architects 1250 Pacific Ave — Suite 700 Tacoma, WA 98402 RE: Request for Permit Application Extension #1 Permit Number EL18-0536 Dear John Wegener, This letter is in response to your written request for an extension to Application Number EL18-0536. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit application through June 11, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. ELI 8-0536 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov 404 SW Columbia. 4 20 Bend, OR 97702 ce 0 v � = ~ � � m 505 W Rwersid.2 4S00. Soo 12SO Pac fic Avenue 4700. Tacoma WA 98402 November 6, 2018 Mr. Jerry Hight Tukwila Building Official City of Tukwita 1 Department of Community Development 6300 Southcenter Boulevard, Suite 100 Tukwila, Washington 98188 SUBJECT: FOSTER HI3H SCHOOL MODERNIZATION AND ADDITIONS 4242S.144TH STREET, TUKWILA, WA 98168 EXTENSION REQUEST FOR PERMIT APPLICATION EL18-0536 Dear Mr. Hight, ""E~°E."E~, CITY " OF TUKWILA NOV����� ��v vw�mv� PERMIT CENTER We are requesting an application extension for Permit Application No. EL18-0536 According to a letter issued by the City of Tukwila, dated November 1, 2018, the referenced Permit Application is approaching an expiration date of December 11, 2018 (copy attached). We are requesting an extension of ninety (90) days, as allowed by the Building Code and noted in the attached Ietter, to finalize the plan review process. A Revision Submittal has been returned to the City in response to the Correction Letter that was issued by the City for this permit. A general contractor is about to be selected by the Tukwila School District for this public school project and it is anticipated that an application for a building permit will be forthcoming within the 90 day extension period. We thank you for your consideration of this request. If you have any questions please contact me. Sincerely, Wegener, Al ect Manage Request fo, Extensiol # '� Cunpn/CxpiradouDate: .,+. Extension Request: Approved for /" � Li Denied ( 1 exp anal on, Attachment: City of Tukwila letter dated November 1, 2018 cc: Jeff FeeneyTukwila SD Project Manager KMB Architects Andreia Brown, Assistant Project Manager - KMB Architects days '/ Signature nitials TACOMA rj (253) 527.5599 SPOKANE (509) 252,50E30 PORTLAND f/ (503) 595 BEND /7ew»33uouom 11/1/2018 f � City of Tukwila Department of Community Development JEFF FEENEY 906 COLUMBIA ST SW, STE 400 OLYMPIA, WA 98501 RE: Permit Application No. EL18-0536 FOSTER HIGH SCHOOL 4242 S 144TH ST Dear JEFF FEENEY, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/11/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of UNDER REVIEW and is due to expire on 12/11/2018. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: EL18-0536 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 October 9, 2018 City of Tukwila Department of Community Development 6300 Southcenter Blvd, Tukwila, WA 98188 Attn: Bill Rambo RE: Foster High School, 4242 S 144th St — ELECTRICAL Permit Application Number EL18-0536 Dear Mr. Rambo, The electrical documents have been revised to comply with the Electrical comments received on July 5, 2018. Please see our responses below for your approval: Comment 1: SHEET E6.03 INDICATES SDB#2 FURNISHED WITH 2500 AMP GFPE MCB. SHEET E6.21 INDICATES 1600 AMP MLO. GFPE REQUIRED FOR THIS FEEDER. Response: The SDB#2 has been revised to MLO. The new Main Service Distribution Board "MDB" will be provided with the GFCI main circuit breaker. Comment 2: SHEET E6.03 PANEL P1A INDICATES 400 AMP MCB, REVISE TO 200 AMP MCB. Response: Panel P1A has been revised to a 200A panel MCB. Comment 3: SHEET E6.15 NEW PANEL 4C IS 200 AMP RATED WITH A 300 AMP BREAKER TO TRANSFORMERFEEDING PANEL 2C1. Response: The Transformer feeding panelboard 2C1 has been reduced to a 112.5kVA from 150kVA. The circuit breaker on Panel 4C feeding the transformer is 175A. Please do not hesitate to call with any questions or concerns. Sincerely, BCE ENGINEERS INC. enr tos Sr. Elec ical Designer, Associate •• 0S -3G CORRECTION LTR# RECEOVE© CITY OF TUKWIL OCT 09 231d PERNT CENTER BCE En: neers, Inc. 6021 12th St. East, Suite 2 Fife, Washin:ton 98424 P 253.922.0446 F 253.922.0896 July 05, 2018 City of Tukwila Department of Community Development JEFF FEENEY 906 COLUMBIA ST SW, STE 400 OLYMPIA, WA 98501 RE: Correction Letter # 1 ELECTRICAL Permit Application Number EL18-0536 FOSTER HIGH SCHOOL - 4242 S 144TH ST Dear JEFF FEENEY, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Jim Benner at 206-431-3679 if you have questions regarding these comments. CORRECTIONS/ #1 1). SHEET E6.03 INDICATES SDB#2 FURNISHED WITH 2500 AMP GFPE MCB. SHEET E6.21 INDICATES 1600 AMP MLO. GFPE REQUIRED FOR THIS FEEDER. 2). SHEET E6.03 PANEL PIA INDICATES 400 AMP MCB. REVISE TO 200 AMP MCB. 3). SHEET E6.15 NEW PANEL 4C IS 200 AMP RATED WITH A 300 AMP BREAKER TO TRANSFORMER FEEDING PANEL 2C1. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Ren2 Bill Rambo Permit Technician. File No. EL 18-0536 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 CPERMIT COORD COW, = PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0536 DATE: 10/09/18 PROJECT NAME: FOSTER HIGH SCHOOL SITE ADDRESS: 4242 S 144 STREET Original Plan Submittal X Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 31!) AtAx Building Division Public Works 10-31-fg r Fire Prevention Structural Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/11/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 11/08/18 Approved with Conditions 11)4 Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INMALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg EI Fire 0 Ping PW Staff Initials: 12/18/2013 I.\PERMIT COORD COPY: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0536 DATE: 06/18/18 PROJECT NAME: FOSTER HIGH SCHOOL SITE ADDRESS: 4242 S 144TH ST X Original Plan Submittal Revision # before Permit Issued Deferred Submittal # Revision # after Permit Issued DEPARTMENTS: - 1—)---40 ,Wing Digioh Public Works Fire Prevention Structural LI Planning Division LIPermit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 06/19/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved ri Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues DUE DATE: 07/17/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 7-34 S Departments issued corrections: Bldg 3 Fire 0 Ping 0 PW 0 StaffInitials: 12/18/2013 ` City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10/9/18 Plan ChecWPermit Number: EL18-0536 E/ Response to Incomplete Letter # IN: Response to Correction Letter #1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Foster High School Modernization & Additions Project Address: 4242 S 144th Street, Tukwila, WA 98168 Contact Person: Henry Santos (BCE Engineers) Phone Number: 253-922-0446 Summary of Revision: (SEE ATTACHED REVIEW COMMENT RESPONSES) RECEIVED CITY OF TUKWILA OCT 092018 PERMIT CENTER Sheet Number(s): E6.02. D6.03. E6.15. & E6.16 "Cloud" or highlight all areas of revision includin date of revion Received at the City of Tukwila Permit Center by: L — Entered in TRAKiT on 10 " W:\Permit Center\Templates \Forms\Revision Submittal Form.doc Revised: August 2015 TEKNON CORPORATION Washington State Department of Labor & Industries I Ionic Espanol Colltnet. Safety & Health Claims & Insurance Search L&I AZ Index Help Workplace Rights TEKNON CORPORATION Owner or tradesperson Principals SPENCER, GORDON, PRESIDENT STOBAUGH, NEAL, VICE PRESIDENT C T CORPORATION SYSTEM, AGENT SMITH, ROGER B (End: 10/03/2012) SMITH, GAIL (End: 10/03/2012) Doing business as TEKNON CORPORATION WA UBI 600 525 922 10675 Willows Rd NE Ste 100 REDMOND, WA 98052 425-895-8535 KING County Business type Corporation Governing persons GORDON J SPENCER NEAL STOBAUGH; ROGER 13 SMITH; RANDY RANDAL OWNBEY; GAIL LOUISE SMITH; License Verify the contractor's active registration / license / certification (depending on (rade) and any past violations. Electrical Contractor License specialties LIMITED ENERGY License no. TEKNOC*062J8 Effective — expiration 04/28/1994— 09/24/2020 Designated administrator Spencer, Christopher James License type Master Electrician Bond FIDELITY & DEPOSIT CO OF MD Bond account no. LPM 08672321 Received by L&I 08/11/2003 Active. Meets current requirements. Active. Meets current requirements. License no. SPENCCJ835B0 $4,00000 Effective date 08/01/2003 Expiration date Page 1 of 3 .I[ My Trades & Licensing Help us improve https://secureini.wa.gov/verify/Detail.aspx?UBI-600525922&LIC=TEKNOC*062,18&SAW= 1/9/2019 TEKNON CORPORATION Page 2 of 3 Savings No savings accounts during the previous 6 year period. License Violations Infraction no. ECMIE00405 Issue date 08/30/2018 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EBOES00856 Issue date 01/05/2015 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain an electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Infraction no. EBOES00841 Issue date 01/05/2015 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to request an inspection within 3 business days after completion of the installation or 1 business day after energizing, whichever occurs first as referenced in WAC 296-46B-901. Until Canceled Satisfied RCWNVAC 19.28.101 RCW Violation amount $250.00 Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Satisfied RCW/WAC 19.28.101 RCW Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 122,206.00 Doing business as TEKNON CORPORATION Estimated workers reported Quarter 3 of Year 2018 "Greater than 100 Workers" Account is current. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600525922&LIC=TEKNOC*062J8&SAW= 1/9/201.9 TEKNON CORPORATION L&I account contact T1 / FEARAED FEROZE (360)902-4797 - Email: FERH235@Ini.wa.gov Track this contractor Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/10/2013 Inspection no. 316831379 Location 202 Westlake Ave Seattle, WA 98109 No violations Page 3 of 3 Wrishiegion State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600525922&LIC=TEKNOC*062J8&SAW= 1/9/2019