Loading...
HomeMy WebLinkAboutPermit EL18-0690 - NATERA - WAREHOUSE TENANT IMPROVEMENTNATERA 3215 S 116 ST 109 ELI 8-0690 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0923049066 3215 S 115TH ST 109 Project Name: NATERA ELECTRICAL PERMIT Permit Number: EL18-0690 Issue Date: 9/12/2018 Permit Expires On: 3/11/2019 Owner: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: WAYNE BREWSTER Address: 918 CEDAR AVE , MARYSVILLE, WA, 98270 Contractor: Name: H & M ELEiCTRIC INC Address: PO BOX 799 , MARYSVILLE, WA, 98270 License No: HMELEI*077KR Lender: Name: Address: *11 Phone: (360) 386-1554 Phone: (360) 658-0501 Expiration Date: 5/19/2019 DESCRIPTION OF WORK: WAREHOUSE TENANT IMPROVEMENT Valuation of single family: 50.00 Valuation of mf/comm: $180,000.00 Type of Work: GENERATOR Fees Collected: $3,522.39 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edi.:ion: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Date: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 9//? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: ago D 415 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3215 South 116th Street Suite Number: 109 Floor: 0 Tenant Name: Natera PROPERTY OWNER Name: Address: City: State: Zip: CONTACT PERSON — person rece:.ving all project communication Name: Wayne Brewster Address: 918 Cedar Ave Address: 918 Cedar Ave City:Marysville State: WA City: Marysville State WA Zip: 98270 Phone: (360) 658-0501 Fax: (360) 658-0502 Email: Wayneb@hmelec.com New Tenant: ® Yes ❑ ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: H&M Electric Inc, Address: 918 Cedar Ave City:Marysville State: WA Zip: 98270 Phone: (360) 658-0501 Fax: (360) 658-0502 Contr Reg No.: Exp Date: Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 180,000 Scope of Work (please provide detailed information): Warehouse Tenant Improvement Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? 11Z1 Yes ❑ No Type of Use: Back up generator Type of work: ❑ New ❑ Addition 0 Service Change 0 Remodel m Tenant Improvement 0 Low Voltage m Generator 0 Fire Alarm ❑ Telecommunication 0 Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light W:\Permit Center \Applications-HandoutsV'ermit Applications \PDFs\Electrical Permit Application Revised 1-I-17.docx Revised: January 2017 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE; ❑ New single family dwellings $155.91 (including an attached garage', ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without serv.ce change $55.69 (up to 5 circuits) ❑ Circuits added/altered without sery__ce change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $6L05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES 0 Temporary service (residential) $66.30 O Temporary service (generator) $82.52 O Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated, I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL ONTRACTOR: Signature: li'��j�r� .��_ ,�,�r%� Date: 08/07/2018 Print Name: WayVBrewster Day Telephone: (360) 386-0501 Mailing Address: 918 Cedar Ave Marysville WA 98270 City W:\Permit CemerlApplicanions-Handouls'Pcrmit ApplicationsC'DFs\Eleclnce! Permit Application Revised I-I-t7.docz Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R15112 DESCRIPTI PermitTRAK NS I ACCOUNT QUANTITY I PAID $3,522.39 EL18-0690 Address: 3215 5 116TH ST 109 Apn: 0923049066 $3,522.39 ELECTRICAL $3,386.91 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $2,709.53 PLAN CHECK FEE R000.345.832.00.00 0.00 $677.38 TECHNOLOGY FEE $135.48: TECHNOLOGY FEE TOTAL FEES PAID BY RECE R000.322.900.04.00 0.00 $135.48 PT: R15112 $3,522.39 Date Paid: Wednesday, August 08, 2018 Paid By: H&M ELECTRIC Pay Method: CHECK 35722 Printed: Wednesday, August 08, 2018 9:44 AM 1 of 1 IN5PCTION NO. INSPECTION RECORD Retain a copy with permit 6.? PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Insp tion Request Line (206) 438-9350 Project: fType ki.4-7-64(A- of Inspection: r-fri Address:..Date 4c5- Il(p sr-- Called: Date Wanted: / P. Special Instructions: Requester: Phone No:360 322- 2-360 711 COMMENTS: Approved per applicable codes. Corrections required prior to approval. ao, Inspector: I,L61)\ REINSPECTIO FEE REQUIRED, Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspeclion, Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 rojec: jiorreix 56 - Type a Irispection: iliCir Iesiqi: "4 Mt Addre :-,Date ir-5. #45r. Called: SpecialInstr..ictions: Date Wanted: (00 Requester: 22J PkJtt5,fr? Phone No: (WI- ad Approved per applicable codes. Corrections required prior to approval. t OMMENTS: \I #' LA t5e C A ACC. ti., 22J PkJtt5,fr? (WI- ad Inspector: REINSPECTION FEE REQUIRED. Prior to next insped on. We must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Z, INSPECTION RECORD 1.4 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd_, #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431 - Project: i krekA- Type of Inspectign6 �v Date Called: L /1' 1 S � _ Address: 4-1 SSIl(0W. Special Instructions:Date * /© 9 Wanted: 0 � a. m Requester: Phone No: Ap troved per applicable codes. a Corrections required prior to approval. C©MMENTi: U6i.cf\ A -I' Inspector: Date: n REINSPE:CTI y N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPEC ION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: I Al , l Type of Inspection ad [AI Address: 2( fa0 Sr; Date Called: Special Instructions: /0 7 Date Wanted: 11// (( ` / am: Requester: Phone No: 3�� 3 V 6 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: At-frt cocit/ Inspector: '� 6/46c Date: DVi 3/ib inspection. fee must be FEE REQUIRED. Prior to next REINSPECTION paid at 63C00 Southcenter Blvd., Suite 100. Call to schedule reinspection. (PERMIT COORD COP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0690 DATE: 08/08/18 PROJECT NAME: NATERA SITE ADDRESS: 3215 S 116TH ST Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AuC, So -R-46 Building Division 1111 Public Works Fire Prevention Structural C Planning Division Permit Coordinator n PRELIMINARY REVIEW: DATE: 08/09/18 Not Applicable Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Lil Approved with Conditions Corrections Required J Denied (corrections entered in Revews) (ie: Zoning Issues) DUE DATE: 09/06/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW D Staff Initials: 12/18/2013 H & M ELECTRIC INC Hcnne Espafiol Contact Search L&I A -Z index Help Safety & Health Claims & Insurance Workplace Rights OWashington State Department of Labor & Industries H & M ELECTRIC INC Owner or tradesperson Principals MCCANN, KENNETH F, PRESIDENT MCCANN, JOSEPH F, VICE PRESIDENT CHMELIK, SITKIN & DAVIS PS, AGENT Doing business as H & M ELECTRIC INC PO BOX 799 MARYSVILLE, WA 98270 360-658-0501 SNOHOMISH County WA UBI No. Business type 601 461 695 Corporation Governing persons JOSEPH F MCCANN KENNETH F MCCANN; License Verify the contractor's active registration / lioanse / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. HMELEI*077KR Effective — expiration 05/1911993— 05/19/2019 Designated administrator MCCANN, JOSEPH F License type Electrical Administrator Bond Merchants Bonding Co (Mutual) Bond account no. WA28643 Active. Meets current requirements. Active. Meets current requirements. License no. MCCANJF077LF $4,000.00 Received by L&I Effective date 10/28/2013 12/13/2013 Expiration date Until Canceled Page 1 of 2 StAitCH.' My 1,8d Trades & Licensing Bond history Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.goviverify/Detail.aspx?UBI=601461695&LIC=HMELEI*077KR&SAW= 09/12/2018 H & M ELECTRIC INC Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 844,746-00 Doing business as H & M ELECTRIC INC Estimated workers reported Quarter 2 of Year 2018 "51 to 75 Workers" L&I account contact T2 / DALE RIUTTA (360)902-4834 - Email: RIUD235@lni.wa.gov Account Is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor 8 Industries. Use of This site is subject to the laws of the stale of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601461695&LIC=HMELEI*077KR&SAW= 09/12/2018 ELECTRICAL SYMBOL SCHEDULE SYMBOLS OXYGEN SYMBOLS LIGHTING SYMBOLS NOTES )J M LED, SURFACE OR RECESSED LIGHT FIXTURE AND OUTLET BOX, NORMAL ® 02 DEFICIENCY BEACON 18" AFF 0 9 WALL MOUNTED LIGHT FIXTURE AND OUTLET BOX, NORMAL HA 02 CONTROLLER 1 1 ►�� LED STRIP; SURFACE, RECESSED OR SUSPENDED LIGHT FIXTURE, NORMAL G CEILING 'E' STEP LIGHT PHOTOELECTRIC SMOKE DETECTOR D -o -Q AREA LIGHTING POLE WITH FIXTURE(S) MANUAL MOTOR STARTER WITH THERMAL OVERLOAD •Q FLOOD LIGHTING FIXTURE VARIABLE FREQUENCY DRIVE _2_2.42_ LIGHTING TRACK WITH FIXTURES; LENGTH AS SHOWN ON PLANS F EQUIPMENT CONNECTION EMERGENCY BATTERY UNIT u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE ® -® EXIT SIGN, SINGLE FACE, CEILING OR WALL MOUNTED; ARROWS AND FACE AS SHOWN ON PLANS e „e EXIT SIGNCES, DOASUBLESHOWNOFACE, N PLCEILINGANS OR WALL MOUNTED; ARROWS TRANSFORMER 0 22 Y411 i T ABBREVIATION AFF ABOVE FINISHED FLOOR E EXISTING DRY CLOTHES DRYER FACP FIRE ALARM CONTROL PANEL HRS HORSE RATED SWITCH PROJ PROJECTOR REF REFRIGERATOR ICE ICE MACHINE MS MOTORIZED SCREEN MW MICROWAVE OVEN NIC NOT IN CONTRACT VM VENDING MACHINE WM WASHING MACHINE SYMBOLS OXYGEN SYMBOLS NOTES PUSH BUTTON LD2 SHUTDOWN MOTOR OUTLET D ® 02 DEFICIENCY BEACON 18" AFF 0 02 DEFICIENCY CENSOR WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN HA 02 CONTROLLER MOTOR STARTER ►_+ SYMBOLS POWER SYMBOLS NOTES 0 MOTOR OUTLET 1 VOICE/DATA OUTLET, RING AND PULL STRING TO ACCESIBLE CEILING FUSED DISCONNECT SWITCH SWITCH XX/XX/XX = AMP SWITCH/POLES/AMP FUSE 18" AFF CP HEAVY DUTY NON-FUSED DISCONNECT SWITCH SWITCH XX/XX = AMP SWITCH/POLES WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN G MOTOR STARTER N/A ►�� DATA OUTLET, CEILING MOUNTED G CEILING N/A COMBINATION MOTOR STARTER PHOTOELECTRIC SMOKE DETECTOR ►tel ST MANUAL MOTOR STARTER WITH THERMAL OVERLOAD 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET REMOTE ANNUNCIATOR VARIABLE FREQUENCY DRIVE -® WE F EQUIPMENT CONNECTION AUTOMATIC TRANSFER SWITCH u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE 120V, DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED TiKVA_r "41.1Y TRANSFORMER 0 22 Y411 i T 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED TRANSFORMER 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED 224) p STATIONARY CIRCUIT BREAKER; RATING AS SHOWN ON PLANS S <<"No>> DRAWOUT CIRCUIT BREAKER; RATING AS SHOWN ON PLANS DOUBLE POLE SWITCH —oho -1=0 WII N RAND EFU E; RATING AS SHOWN ON PLANS SWITCH CULE S4 —off!'- SWITCH AND FUSE; RATING AS SHOWN ON PLANS SINGLE POLE SWITCH WITH PILOT LIGHT SK AVAILABLE FAULT CURRENT IN AMPERES SD DIMMER SWITCH ® DIMMER SWITCH WITH 3 -WAY SWITCHING I F NORMALLY OPEN CONTACT SM 34 NORMALLY CLOSED CONTACT TIMER SWITCH -0 , JQ JUNCTION BOX -❑Q PUSH BUTTON STATION SOS WALL MOUNTED OCCUPANCY SENSOR W/OVERRIDE SWITCH PHOTOCELL CEILING MOUNTED OCCUPANCY SENSOR PC WALL MOUNTED OCCUPANCY SENSOR TIME CLOCK TC PB CONTROL PANEL FURNISHED WITH EQUIPMENT iZ CP WIRING DEVICE KEYED NOTES THE FOLLOWING NOTATIONS MAY BE USED WITH ANY RECEPTACLE TYPE TO FURTHER DEFINE THE SYMBOL: M = FOR MONITORING EQUIPMENT, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT. 0 = EQUIPMENT SYSTEM RECEPTACLE, PROVIDE SPECIAL LABEL, SEE SPECIFICATIONS. T = TAMPER RESISTANT RECEPTACLE. TV = FOR TELEVISION, COORDINATE MOUNTING HEIGHT WITH TELEVISION. WP= WEATHERPROOF, CORD CAN BE PLUGGED IN WITH COVER CLOSED. USB = USB DUPLEX RECEPTACLE WITH 2 USB PORTS RATED AT 2A MINIMUM AT 5V. THE FOLLOWING NOTATIONS MAY BE USED WITH MOST SWITCH TYPES TO FURTHER DEFINE THE SYMBOL: $ = A LINE THROUGH THE SWITCH SYMBOL MEANS THE DEVICE SHALL BE RED WITH A RED COVER PLATE IF PLASTIC PLATES ARE USED. LIGHTING CONTACTOR 1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE WSEC. 2. AS REQUIRED BY SECTION C405.13 ALL LIGHTING SYSTEMS SHALL BE COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD PARTY AGENCY. 3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON THE PLANS. 4. AS REQUIRED BY SECTION C408.1.3 THE COMMISSIONING DOCUMENTS DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. LC 208V/120V SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET 208v/120v FLUSH MOUNTED PANELBOARD OR TERMINAL CABINET SYMBOLS VOICE AND DATA SYMBOLS BACKBOX MTG. HT. POWER 1 VOICE/DATA OUTLET, RING AND PULL STRING TO ACCESIBLE CEILING G 18" AFF N/A Q WAP WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN G 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET N/A r.„41 DATA OUTLET, CEILING MOUNTED G CEILING N/A SYMBOLS FIRE ALARM SYMBOLS ---- ---- --- 0 HORN/STOBE 120V, CONTROLLED DUPLEX RECEPTACLE OUTLET til 120V, 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET 0 SPEAKER/STOBE 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET 4 0 MANUAL PULL STATION 120V, ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE OUTLET 4 120V, CONTROLLED DOUBLE DUPLEX RECEPTACLE OUTLET CO PHOTOELECTRIC SMOKE DETECTOR is ,o changes es shall be made 120V, ABOVE COUNTER 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET REMOTE ANNUNCIATOR SPECIAL PURPOSE RECEPTACLE, VOLTAGE AND NEMA RECEPTACLE TYPE AS NOTED -® WALL MOUNTED EQUIPMENT CONNECTION F EQUIPMENT CONNECTION SYMBOLS AUDIO/VISUAL SPEAKER SYMBOLS SECURITY CAMERA SYMBOLS WIRING DEVICE SYMBOLS IO 120V, DUPLEX RECEPTACLE OUTLET CONDUIT INSTALLED CONCEALED ABOVE CEILINGS OR IN WALLS IN FINISHED AREAS OR EXPOSED IN UNFINISHED AREAS 120V, A3OVE COUNTER DUPLEX RECEPTACLE OUTLET me 120V, CONTROLLED DUPLEX RECEPTACLE OUTLET til 120V, 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET KEY NOTE TAG 120V, ABOVE COUNTER 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET 4 120V, DOUBLE DUPLEX RECEPTACLE OUTLET 9 120V, ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE OUTLET 4 120V, CONTROLLED DOUBLE DUPLEX RECEPTACLE OUTLET 41 120V, 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET is ,o changes es shall be made 120V, ABOVE COUNTER 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET -® SPECIAL PURPOSE RECEPTACLE, VOLTAGE AND NEMA RECEPTACLE TYPE AS NOTED -® WALL MOUNTED EQUIPMENT CONNECTION ® EQUIPMENT CONNECTION G u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE 120V, DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED 120V, DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED L J 0 22 Y411 i 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED c L J 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED 224) SURFACE RACEWAY - TYPE, OUTLETS, SPACING AND FINISH AS NOTED S SINGLE POLE SWITCH S2 DOUBLE POLE SWITCH S3 3 -WAY POLE SWITCH S4 4 -WAY POLE SWITCH SP SINGLE POLE SWITCH WITH PILOT LIGHT SK SINGLE POLE KEY OPERATED SWITCH SD DIMMER SWITCH SD3 DIMMER SWITCH WITH 3 -WAY SWITCHING SV VARIABLE INTENSITY CONTROL FOR SURGICAL LIGHT SM MANUAL MOTOR STARTER SWITCH W/THERMAL OVERLOAD PROT. ST TIMER SWITCH SLM LOW VOLTAGE MOMENTARY CONTACT SWITCH (TOGGLE STYLE) D PUSH BUTTON SWITCH SOS WALL MOUNTED OCCUPANCY SENSOR W/OVERRIDE SWITCH OS CEILING MOUNTED OCCUPANCY SENSOR OS WALL MOUNTED OCCUPANCY SENSOR P PUSH PLATE (FOR AUTOMATIC DOOR) PB PUSH BUTTON (FOR AUTOMATIC DOOR) iZ PHOTOCELL SWITCH WIRING DEVICE KEYED NOTES THE FOLLOWING NOTATIONS MAY BE USED WITH ANY RECEPTACLE TYPE TO FURTHER DEFINE THE SYMBOL: M = FOR MONITORING EQUIPMENT, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT. 0 = EQUIPMENT SYSTEM RECEPTACLE, PROVIDE SPECIAL LABEL, SEE SPECIFICATIONS. T = TAMPER RESISTANT RECEPTACLE. TV = FOR TELEVISION, COORDINATE MOUNTING HEIGHT WITH TELEVISION. WP= WEATHERPROOF, CORD CAN BE PLUGGED IN WITH COVER CLOSED. USB = USB DUPLEX RECEPTACLE WITH 2 USB PORTS RATED AT 2A MINIMUM AT 5V. THE FOLLOWING NOTATIONS MAY BE USED WITH MOST SWITCH TYPES TO FURTHER DEFINE THE SYMBOL: $ = A LINE THROUGH THE SWITCH SYMBOL MEANS THE DEVICE SHALL BE RED WITH A RED COVER PLATE IF PLASTIC PLATES ARE USED. 2015 WA STATE ENERGY CODE 1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE WSEC. 2. AS REQUIRED BY SECTION C405.13 ALL LIGHTING SYSTEMS SHALL BE COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD PARTY AGENCY. 3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON THE PLANS. 4. AS REQUIRED BY SECTION C408.1.3 THE COMMISSIONING DOCUMENTS DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. SYMBOLS CONDUIT SYMBOLS NOTES A CONDUIT INSTALLED CONCEALED ABOVE CEILINGS OR IN WALLS IN FINISHED AREAS OR EXPOSED IN UNFINISHED AREAS 15ONG _ _ _ _ CONDUIT INSTALLED BELOW FINISHED FLOOR OR BELOW GRADE KEY NOTE TAG INDICATES CONDUIT TURNING UP --o INDICATES CONDUIT TURNING DOWN —• DETAIL REFERENCE BUBBLE CONDUIT STUBBED OUT WITH BUSHING DETAIL NUMBER REVISIONS is ,o changes es shall be made CONDUIT STUBBED OUT AND CAPPED E1.1 FLEXIBLE CONDUIT WITH SINGLE POINT OF CONNECTION AT ELECTRICAL EQUIPMENT SHEET BEARING DETAIL of rrb1^"t 4 <thr.rot prior 1-,,,.„„„;11.3 R sr rtin) GROUNDING CONDUCTOR MOTOR DESIGNATION TAG I:Liz"`° p,s ctzl y =luta G '--"-'1 CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE SYMBOLS DESIGNATION SYMBOLS NOTES A COLUMN LINE 15ONG FEEDER DESIGNATION TAG KEY NOTE TAG A DETAIL REFERENCE BUBBLE DETAIL NUMBER REVISIONS is ,o changes es shall be made to the scope approval of nmtrir on E1.1 SHEET BEARING DETAIL of rrb1^"t 4 <thr.rot prior 1-,,,.„„„;11.3 R sr rtin) MOTOR DESIGNATION TAG I:Liz"`° p,s ctzl y =luta `' a new plan revival fes. ® 0m A 0 22 FIXTURE DESIGNATION UPPER CASE LETTER INDICATES LUMINAIRE TYPE. LOWER CASE LETTER INDICATES SWITCH LEG NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN). 224) NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN) DRAWING INDEX E0.1 ELECTRICAL SYMBOL LEGEND AND ABBREVIATIONS E0.2 NREC FORM E1.0 FLOOR PLAN - LIGHTING E2.0 FLOOR PLAN - POWER E2.1 FLOOR PLAN - SPECIAL SYSTEMS E3.0 ONE -LINE DIAGRAM E3.1 PANEL SCHEDULES - 4 1 3 1 2 SEPA,TE PERMIT t-QU1RED FOR: 4rMechanicnf 0 Electrical L'Plumbing C1 as Piping - City of Tukwila B0_ `%rn DIVISION .01111 FILE COPY Permit No. ()q° Plan roviaw cpproval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt Of approved Raid Copy and conditions is acknowledged: Date: 4/ia/isr City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA. AUG 082018 PERMIT CENTER REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC AUG 202010 C of.Tukwila '._ION C B A ELECTRIC INC. PO Box 799 Marysville, WA 98270 360-658-0501 www.hmelec.c•orrl ‘Ao MAZZED 19203 36th Ave W. Suite 200 Lynnwood. WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 1 16th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE ELECTRICAL SYMBOL LEGEND AND ABBREVIATIONS SHEET NUMBER E0.1 C B A h 2015 Warrington State Energy Cade Hance Forms for Commete 4 iq4 nv -GT-SUM __---:•-,._-, ._...-..... ..w...,v. tcaw,Lnu /WtrUslavto PrQ act Info Pract .Natera Male 8 3' 2018 Compliance 'Xppilcan, information. Provide contact Information ter Individual who carr Far Ruild(ng Department Use forms do not 'respond tet• Inquiries about cernpiiance form Information provided.. require a , Company anyJam . tczsStpassword tot use,. .. Company Address; 2013 4Th Ave Suite 200 Secede WA 98121 Instructloneel arld r r calculating wit Applicant: Name; Kyle Teegardin eine wrte kotp010(4 Applicant Phonn: 42.5 712-2196' A..ApIicantEail: m ktdagarditii.aoit'I Project Description I New Building Addition , Alteration Plans Included anclude PROJ-SUM form (betided in ern/elopeern/elope tomos *orkbbbk) with li halo corn tlfance� farms. BuildingAdditionsComplraneae Methodlntenorlightlng Exterior lighting Lighting systems In add(tron'area comply with all applicable provisions,; as a>rtand elone"n$w dvn&tructivn project. ^� 1-1 Refer to Section C502:26 for additional re¢ujrernents, Lighting systems iii addidon•are combined with existing- Fl building lighting systems to demonstrate 'compliance - Addition is combined with existing: For interior lightingg projects, include new+ existing Interior lighting fixture ivatta a M Proposed Lighting . , Wattage tableIrr LTG -TNT -.BLD or LTGLIiIT-SPACErorim Forelrxteriarllghting projects. include /3014.' 4,63111.111/V ekterforJ•ghtirtg &Iwo wattage} in,Prap'asecf 'Traffab1a and Proposed Non -Tradable Lighting Wattage tableslrn LTG -EXT form: Li htln Power Interior lighting • Parkin garage Exterior:ll g titin Interior and Exterior !9 s 9 g g 9 9 s g Lighting Alterations 5g% or rnore of existing are replaced [l II il Setect all Lighting Powor•and Lighting Less than 50% of existing, are replaced Control elements that opal+ to the scope g p C� �__l El ofthe retrofit project. ffprofect rncJlydes is combination of spaces, where less than Lamp and/or ballast replacement only - _ : ---- 5t7% 01 fh$ exfating; tfxfures:are replacetf existing total wattage not increased Jrnsomes aces: arid 50% or more of the . spaces, 50% or more replaced. - Thiel lighting power of new existing -to -remain fixtenes shall coptply with total fixtures are replaced in others, then 1 Aer Sections 0405.4.2 and 04.05.5.2. include new + exrstfn to -remain lixtbres in Pro sed ,provide separate fighting power P pa compliance: forms for`thetwa: retrofit Lighting tNatCage labia in LTG -INT -BLD, LTQ fNT SPA CE or t TG f;XT form; Less than .5t17/a' to facts -; Total lighting poWer of new +' existing -to -remain fxtu es shall not exceed the condltians.` Spaces undergoing the sasme A g g typo of retrofit ofitMa be combined into 'one ioa! ligh!ngpawerpriortoalteration- Inciudenew+existlog=a-rema. in'nx ures in iimProposetlighting ligfngpowertonlincan: Wattage tett In LTG-INTLTG:-INT-SPACE or LTG -EXT form. 50% threshold appiles to number of luminaires for interlrrr spaces and parkingr garages, and total Refer to;Sectfon'C503.6 ler additional. inStaJfed wattage for exterior fuminafres; requlremonts, Lighting Controls, Interior lighting Parking .garage Exterior lighting All,aJteretIon lighting con rocs shall be New wiring installed to serve added commissioned per C408.3. fixtures andfor fixtures relocated 10 new [1 [1 'circuit(') New Or moved lightirtgpanel [_I T`1[ [.J Interior space Is recoefigu red - 1-1 luminaires unchanged •orrelocated only New wiring or circuit circuit- For interior lighting,. provide require d manual controls per per 0 405 .2:3.occupancy sensor controls per C405.2.1 daylight resPonsive .controls per C405,24 and apPlication specific lightin i oort1rofs per C4051.5, For exteriorfighting,•prevfde required 'centres per 0405.2,7. �No'changes era being: made re ' f' the interior or aiteriarlightlrg New ormovedpanej- Provide till applicable lighting caotrofs es noted far New Wiring and automatic Systems ard existfn space time switch controls per 0486.2 2. apply ei eWJnt tiers ace; Reconfigured inlet ioY rt ace - Provfd a all ro aired rf titin controls thatto n e uses arid configuration are notP. ,.. 9 0 0 • , ..p . ChengecL• Application specific lighting coritrol,provlsronsper C4f15.2..5 do oat apply to reconfigured spaces. Change of SpaceUse f 7 Existing interior lighting systemsin areas under -going a change In a-Ppw use •ere upgraded ed to comply with LPA' for the`new space l ser Tables C4u5A.2 1 or O405.4.2(2). py P yPe p (i Identify inferior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in 1. TG -INT a n or L'TC-INT SPACE form: h fn =mum., Coda Y, on me R3, R4..avar tti es andel] GT -SUM Revised August 2016 Project Title: Nates Date, 8/3/2018 :. _..- New Lighting In a en viwer.ehouse area. Interior Lighting Power Allowance Method ❑ Building Area Method ' Space -by -space Method scrod method used fn project. Interior Lighting Controls 7- All C405.2.1•- C405.2.8 Controls fl 0405;2 Exception 5 Luminaire Level - Lighting Control (LLLC) Additional Efficiency Package Option '- 0406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total Installed interior lighting power shall comply with the required controls per C406.4. Dwelling Linin: Interior. Lightiitg Permanently installed Interior lighting fixtures in (Availing ,units cornpfy with: '0.' 1 ? C405.2 they C405.5 Commercial Lighting Controls and LPA !. i: i C406.3leleh Efficacy+Lighting r` , Exterior Lighting System Description None Ceiling 9 NOTE 7 Hel ht 9 Interior �rvss Interior Area in 2 it Allowed Wattspar tt2 e. Watls.AltQwed 2 (watts/112x area ('N ft x ) Plan El.a Warehouse: Smaller, hand carried items Lighting contrais, general 6650 0.760 5054 NA C405.2 Luminaire level lighting controts; (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide desorip0on of control capabilities and performance parameters NA Nfti C405.1 Lighting in.0wellang units Fier permanently installed. lighting fikturps.in dwelling units, indicate: lighting control Method on plans tar spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception 0405.3 Flit itlgne Yes 0405:2.3 C405.2.1,1 C405.2.2.2 C405:2,4 C405:2.5 Manual controls Indicate on plans the method of, manual lighting bentrol (whether combined with occupancy sensor. automatic light reduction, daylight responsive or specific application .controls), lonetien of mention controt deeice and area or specirCe application it terries E1.0 Ughing in dwelling units:- taneeefficacy see C442,2,1 C405,222. G405.2.3 Manual interior Iighttng contra(' lndit ate'ore plans which method of manual 50% ligating load redut tlon.15 provided ti rwhctherllghting load is reduced via occupancy. sensors or !daylight responsive controls. E1.0 Reduced lighting power density - dweling unit tamp efncaey Yes 0405.2.2 Method ofautomatic shut=off central indicate en plans the method of automatic strut -off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; E1.0 Mears oregress lighting Lobby Art/Exhibit. Display Allowance from LTG -INT -DISPLAY NOTE a Total Area Retail Display 6650 LTG -INT -DISPLAY Allowed Watts 0405.2.1 0405.2.1.1 Allowance from Indicate on plans the spaices served by occupancy sensors; E1.0 Space-By?Spaee Method 5054 E1.0 i rt05.2ningicloeirer Yee h fn =mum., Coda Y, on me R3, R4..avar tti es andel] GT -SUM Revised August 2016 Project Title: Nates Date, 8/3/2018 Interior Lighting System.sten. Description New Lighting In a en viwer.ehouse area. Interior Lighting Power Allowance Method ❑ Building Area Method ' Space -by -space Method scrod method used fn project. Interior Lighting Controls 7- All C405.2.1•- C405.2.8 Controls fl 0405;2 Exception 5 Luminaire Level - Lighting Control (LLLC) Additional Efficiency Package Option '- 0406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total Installed interior lighting power shall comply with the required controls per C406.4. Dwelling Linin: Interior. Lightiitg Permanently installed Interior lighting fixtures in (Availing ,units cornpfy with: '0.' 1 ? C405.2 they C405.5 Commercial Lighting Controls and LPA !. i: i C406.3leleh Efficacy+Lighting r` , Exterior Lighting System Description None 4 3 Inte 201'. rashiii on tate i in -B B Pace- r ice Mhd e tea p erg Code Compliance Flame fat CommercralBur tden TG -INT -SPACE dud]Rt R4 ove l� ng ;nee and'.. - Project Title: Natera te8/3/2018 Calculation; Area NOTES � i 'i Addition �_',Additivn stand alone +exfskln9 i , Spaces where 4.50% of i' Spaces where 50% of ; , - luminaires We repteoed - letelleuiere aro replaced - 'Date FbrBulldinJ Re artme t Use LPA CalCUlation Type ;:o+ Standard ` , -) Additional Effictenc yPackage Option l "; -- C406:3 Reduced Interim Lighting Power To comply with 04063; /he Repass(' LPD, shall be 25% lower than the Target LPA. Refer to e40B.a for additional Yequirernents.: Maximum Allowed Lighting Wattage N001 Code Section Location( (plan #, room # ) Space Type p Yp Ceiling 9 NOTE 7 Hel ht 9 Interior �rvss Interior Area in 2 it Allowed Wattspar tt2 e. Watls.AltQwed 2 (watts/112x area ('N ft x ) Plan El.a Warehouse: Smaller, hand carried items Lighting contrais, general 6650 0.760 5054 NA C405.2 Luminaire level lighting controts; (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide desorip0on of control capabilities and performance parameters NA Nfti C405.1 Lighting in.0wellang units Fier permanently installed. lighting fikturps.in dwelling units, indicate: lighting control Method on plans tar spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception 0405.3 Flit itlgne Yes 0405:2.3 C405.2.1,1 C405.2.2.2 C405:2,4 C405:2.5 Manual controls Indicate on plans the method of, manual lighting bentrol (whether combined with occupancy sensor. automatic light reduction, daylight responsive or specific application .controls), lonetien of mention controt deeice and area or specirCe application it terries E1.0 Ughing in dwelling units:- taneeefficacy see C442,2,1 C405,222. G405.2.3 Manual interior Iighttng contra(' lndit ate'ore plans which method of manual 50% ligating load redut tlon.15 provided ti rwhctherllghting load is reduced via occupancy. sensors or !daylight responsive controls. E1.0 Reduced lighting power density - dweling unit tamp efncaey Yes 0405.2.2 Method ofautomatic shut=off central indicate en plans the method of automatic strut -off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; E1.0 Mears oregress lighting Lobby Art/Exhibit. Display Allowance from LTG -INT -DISPLAY NOTE a Total Area Retail Display 6650 LTG -INT -DISPLAY Allowed Watts 0405.2.1 0405.2.1.1 Allowance from Indicate on plans the spaices served by occupancy sensors; E1.0 Space-By?Spaee Method 5054 Proposed Lighting Wattage nt3 Location (plan #, teem if) Warehouse Receiving 121 Fixture Description; NOTE 4,$.a Type RL1 Type S1 u of Nmbar Fiettires 541 6 Wade/ Fixture NOTE 7 34 38 Watts Proposed 1836 2.28 Proposed Retail Dlsplay Lighting from LTG -INT -DISPLAY Total Proposed Waits may not exceed Iota/Allowed Watts far interior Lighting Total Proposed Watts Interior Lighting Power Allowance Fo'�` gi 20 09 COMPLIES Natal - List alt• unlges space.types per Table G405.4:2(2J that occur in the projec f.scope. Select space type category per from drop down menu. (dote 2 -Indicate ceiling height for.airfums and spaces utilising the ceiling height adjustment per Tatrie :C405.4.2(2), Footnotes:d thru f. Note 3- List alt proposed lighting avows .fncfetding exempt:lighting'equlpment and existing -to -remain fixtures. -f. t. a a. T-8 numberoflam s in th fixture, and,ballast t... a tfincluded . For Note 4 a�or ropastrdFixturt�t7escnptfon. Indicate' fxtura type. $n'+p yp t J- i, p. p, x •Yp ( 1_ frailer!Wiling, fist the'•len th of the track In feed 'In addition to the f mute, lamp, and ballast inromlat:on. • Note. 5 - Forl titin• e ul trient eligible for exemption err C4o5.4. a note exec tion number and leave Watts/Fixture blank. - manneras fixtures, tdent aS existing 6 - Existing. to -remain fix -titres shteU be Included In the Proposed LkPubrog Wattage table lrl the setae rrrann new x Jfy g itt Igxtute description. Nole 7 For .os d Wetts/"ixture enter the lurniriaIre ae?Ga9e forinatalied iamp and battiest 'using Manufacturer or ether approved SOOtte. te. For iumTnaires with screw-in Ian* enter the mencifacttlrer's tlsted maximum Input wattage of the fixture (not the tamp wattage). For low voltage iighttng, enter the wattage of the trans former. For line voltage tra cklbusway systems, enter the :larger of tire attached hamfnaire wattage or 50 watrsllineal foot; or enter the: wattage Bina ter permanent current 'fruiting device. Note 8 -Lobby Art/ExhibitDisplayAtlovrance is independent of the Maximum Allowed Lighting Wattage. Note 9 -Calculation Area Details: a.. Lighting, fixtures in a building addition May comply as a stand alone prefect, or they may be combined with the overall existing building lighting systems to demonstrate compJtance.Reter to C502.1- b: Foralteratlonsand building additions, pni ride Space Types and $rTss interior areas In the Maximum Allowed Lightin j; Wattage table; if a building addition Mil rxtenniy as cgmbined with the overall. existing building; nighting systems, indude'all applicable exfsting Space Types . . . . . a interior areas. c. If fess than 50% of existing lighting fixtures will be replaced, provide total "exlsiing fighting wattage (prior to alteration) in the space provided LI titin vv - I 20.15 a ngtu �r l"13tc�rrd Electrical Permit Checklist P n Siete Etre Cnr9a Cam fesnrxt Farn+tc .r _ . mmarclal.0utld n s includen R2, R3, R4 war 3 stories and all RI ray p g g LTG -CHK Revised August 2015 Prefect Title: Natera: (Date 8/3f2010 i t• andelectrical ihoiotlawing information is necessary to c a permit appticatlon for cornplianca with the lighting, "mo or, g Cede,Commerelal Provisions. Washiit ton State Energy re. fi uirernients in the Applicability (yes,no,na) Code Section Component Compliance Information requited .Inpermit documents I Location in I Documents. Building Department Notes LIGHTING'CONTROLS Building Department • Notes Yee 0405:2 Lighting contrais, general For all lighting fixtures, indicate lighting control method are plans • for spaces aid lighting zone(S) served, or exception taken E1.0 NA C405.2 Luminaire level lighting controts; (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide desorip0on of control capabilities and performance parameters NA Nfti C405.1 Lighting in.0wellang units Fier permanently installed. lighting fikturps.in dwelling units, indicate: lighting control Method on plans tar spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception 0405.3 Flit itlgne Yes 0405:2.3 C405.2.1,1 C405.2.2.2 C405:2,4 C405:2.5 Manual controls Indicate on plans the method of, manual lighting bentrol (whether combined with occupancy sensor. automatic light reduction, daylight responsive or specific application .controls), lonetien of mention controt deeice and area or specirCe application it terries E1.0 Ughing in dwelling units:- taneeefficacy see C442,2,1 C405,222. G405.2.3 Manual interior Iighttng contra(' lndit ate'ore plans which method of manual 50% ligating load redut tlon.15 provided ti rwhctherllghting load is reduced via occupancy. sensors or !daylight responsive controls. E1.0 Reduced lighting power density - dweling unit tamp efncaey Yes 0405.2.2 Method ofautomatic shut=off central indicate en plans the method of automatic strut -off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; E1.0 Mears oregress lighting Indicate locations where automatic shutoff is provided by other methodsteccupency sonar ',ordigital 'timer evnitch)orwhich . time switch controliaxception applies_ E1.0 Building Area Method Yen 0405.2.1 0405.2.1.1 Occupancy sensor controls Indicate on plans the spaices served by occupancy sensors; E1.0 Space-By?Spaee Method Indicate: whether occupancy sensor controls' are congurad to be manual -on, automatic 50% -on, or serve a epece eligible for automatic 100%-en;per.exceptlpn E1.0 i rt05.2ningicloeirer Yee 0405:2.1.2 occupancy sensor connote =• warehouses Indicate aisleways and'open areas inwarehouse spaces jitevided with at:eupancy, sensor controls that reduce Periling power by aro% E1.0 NA C405.2.6 Digital lamer switch, Indicate required digital itmer switch central function When control, is"used NA 0485;5.1 Yes -2 :E1.0 04052 1 Automatic time switch controls Indicate locations'of override switches on pians and the ligating zone(s) seared; Include area eq: ft NA 04012.5be ilk C445.2.4.2 0405 2.4.3 Daylight zones - Sidelight and topllght Indicate primary and secondary sidelight daylight zoneareas on pians, include SO. ft.; ui .I di l . wi or V that no 20" m circuit centro lea single s tch Verify arnp u by 9 automatic control is loaded beyond 80% Indlcatebuilding exterior lighting zone as defined by the AHJ Indicate toplight daylight zone areas. on plans; include: sq. ft.; NA 0406.4 For small vertical:fenestration assemblles (rough opening less than 10'percent of primary daylight zone) where daylight responsive controls ave not required, provide fenestration area tri deygght 2a5ne) oaiculatign(e) • To comply Withn ditioial efficiency peokag e tion Indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dinemin or exception taken; p. 9. P building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated tamp effioany (in Mulatto per watt) in' fixture schedule to, 0405.2.4 0eyiightresponsfvo controls Indicate. on plans lighting zones) served by. daylight responsive controls; NA 0405.13 Identify sidelight and topligltt daylight zones that are not provided with daylight sensing controls and the excepfon(a) that apply; If claiming lighting system 'cameessioningexemption provide supporting •calculation;.' Indicate on plans,:ttie fighting load reduction method - centintious dimming; or stepped dimming that provides at least two even ste;psbetween 0%-100%' of rated power; Identity applicable commissioning documentation requirements per Section 0408 or eligibility -for exception;• Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone Provide written procedures for functional testing of all automatic controls and describe the expected system response Ntr Orr." 4 5 Additional controlsnatio -• specific appl(tateon lighting contrail- , Identify spaces and lighting fixtures on plans that require specific application lighting controls per leis section NA C+t05.2 5 - 0405. .5 Itemsspace: Display and accent lighting Indicate on pians that display and accent lighting; and display ca•se lig•hting are controlled Independently frons both general area lighting and other lighting applications Within the same Indicate manual and automat -lighting control: method 3 2 ig inotor and,Electric �P 2015 W shl n rrSt a _ gto air Energy Compliance Farms Check Per 1t eCk 115: L TG�C HK farCammorciei t3utdln s l lad R rro a 2 Ra A r 9 R over 3 stoles n9 d s and d I R1 R vlst3d A 2 t , e Ugu9t it 6 Project Title: Natera ' (Date 8/3/2018 The folloWlrig information s ne. cessary to checka penult application for ro_ m Ii erica with the lighting, Mater, a nd electrical State Energy Code, Commercial Provisions.. require .mants h theWashington Applicability (yes,no,na) Code Section Component Compliance information required in permit documents q . p .. Location in Documents Building Department • Notes Na 0405,2; i Item 3 Iiotevmoiet guest reams Indicate method of automatic contra' - vacancy+ or captive key control of all Installed luminaires and switched receptacles in guest MOM E1.0 NA 0445:2:5 Item 4 • Supplemental task lightingcontrol , Indicate' method and lecelionofautomatic shut-off vacancy. for supplemental task lighting, including under sharf or Min et 9 underesbin lighting g NA NA 4' C405.2.5 • Itn15 i L.ghting far non - visual applltlon$; Indicate op planseligible non -visual lighting applications, include sq. it..area of each lighting control zone; 0405.3 Flit itlgne Indicate on plans' that non -Visual lighting are<contr lied Independently both general area lighting and other li•ghting applications within the same space; pP Ef .0. 04.05.9.1 Indicate method of manual lighting control and applicable automatic lighting control C44ca.1 Ughing in dwelling units:- taneeefficacy NA 0405,2.5- Ilam 6 Lightng equipment for sola or demcnstratlon indicate an plans that lighting equipment for site or demonatredon are controlled independently from both general arealeanin• and ether lighting applications within • -the same leaning 9 9 space: C405,3 Reduced lighting power density - dweling unit tamp efncaey indicate method of manual tlghting control and applicable automatic lighting control NR c:405:9.2 Yes C405.2.5 • Item 7 Mears oregress lighting leenttfy on plans; egress: fixtures that function as both normal and emergency means of egress illumination; E1.0 Building Area Method Provide catculaticn of lighting; power density of total egress lighting: indicate all one-way dcwn or reversible escalators are provided with 'a vaiiabie frequency regenerative drive If total.egress lighting power, density fs greater than 0.02W/sq., 11., Indicate on plans egress fixtures requiring automatic shut-off during unoccupied period's; Indicate method'' of automatic shut-off control Space-By?Spaee Method Complete required compliance forms - total preposed wattage does not exceed maximum allowed wattage: Identify locations of space types on plans, including; retail die>play areas, lobby art & exhlbltdisptay+areas. and ceiling heights as applicable Nit i rt05.2ningicloeirer Exteriorlighfing controls Intik-tate on exterior lighting plans and fixture schedules hs automatic lighting control method, control sequence, and'. lacetlons served; Reduc$d lighting power density To comply with additional efficiency package option, demonstrate In compliance forms' that total connected interior' lighting wattage Is 75% less than the total maximum allowed lighting wattage via BuirdingiArea Method or Space -By -Space Method For building fa ade and landscape lighting, indicate automatic reheats' shut off lighting ase function of dewnfdusk and fixed time; EXTERIOR LIGHTING POWER & EFFICACY- For all other exlarlor ltghttng, indicate automatic controls shut off lighting as a function of available daylight; include -control sequence that also reduces lighting power by at least 30% batwean 12am-Sam, orfrom 1 hour after dsing to 1 hour before opening, or based upon motion sensor NA 0405,5;2: NA 0485;5.1 xt eitor bulkting Egr4eror ligtiiing cantrals For budding grounds fixtures greater than 100 watts; Indicate on plana whether fixtures have eiticacy greeter than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C4ti5,5..2 Identify exterior: applications eligible for lighting power exemption on plane and In compliance forms: indicate exceptiem applied; NA 04012.5be Area conttols - c ntrols trol switches and circuit power limit Indicatelocation(s) of master control switch(es) intended to - control multiple independent switches; circuit breaker may not used as a mater control switch; NA Table C405,6.2(t) ui .I di l . wi or V that no 20" m circuit centro lea single s tch Verify arnp u by 9 automatic control is loaded beyond 80% Indlcatebuilding exterior lighting zone as defined by the AHJ NA 0406.4 Enhaiced digital lightingcontrols To comply Withn ditioial efficiency peokag e tion Indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dinemin or exception taken; p. 9. P building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated tamp effioany (in Mulatto per watt) in' fixture schedule Include.cacufat[on of percent total Installed intedatlfghiin g Power that isconfiguredwIt re required enhanced'lig lighting conrol functions (min 90% to comply with additional efficiency package option) NA C405,5.2' NA 0405.13 Lightng system functonal testing If claiming lighting system 'cameessioningexemption provide supporting •calculation;.' Identity applicable commissioning documentation requirements per Section 0408 or eligibility -for exception;• Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting; �lt�t�)r -ar��d lect3"ic�ll 2015 Washington Stale End Code Compton Feump gd�4' p. Perm 1t Checklist P � l� iT1 � On e. t R2 , r ries l rot Cornmerdat Bu din Irn;lud n9 2,. R3, RA wet 3 sto es end all R1 � C LTG -CHK Revised u_ 2 t6 August 0 Project Title: Natera iDate 8%3/2018 The foilowin information is necessary to check 'a permit application forcomeliance with the lighting, motor, and electrical 9 ry_ Washington State Energy Cade, Commercial Provisions. requirements le the Applicability (yles,rto,na) Code Section Component Compliance information required in permitdocuments I Location InBuilding Documents i Department Notes' INTERIOR LIGHTING FONER & EFFiCACY� runding Department rtment Notes: Yea ttM105,-0:1 C405.41 0405,4:2 Tota connected inleror tiyhVng power Include all luminaires In lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated Watts per fixture; E1.0 Identify; spaces eligible for lighting power exemption on pians and in oampltanao farms; lndicaty the exception applied; NA C405,7: Idsnttfyi1ightlng equlpnaent eligible iarlighting power exemption in fikture schedule and in compliance fortes; indicate the exception applied; NA Indieate that exempt fighting equipment Is in addition to general area lighting and is controlled independently NA 0405:8 'Yee 0405.3 Flit itlgne Indicate location d'art!. signs on plans and rated watts per fixture in lighting fixture schedule (maximum' 5 watts perfixtune) Ef .0. 04.05.9.1 NA' C44ca.1 Ughing in dwelling units:- taneeefficacy If high efficacy exception is applied to permanently Installed Iis&ohhtedule if lampg fixtures sn In fixtures am hg igh efficaccate y lighting R404.1, I?9• Y. P Calculate percentage of fixtures with high efficacy lamps` in Project (min 75% to comply with exception): Indicate rated watts per foretevatorcab ventllation fans da not exceed;0,33 watts:per ofm;. NA C405,3 Reduced lighting power density - dweling unit tamp efncaey For project with dwelling units. toeornpiywtth additional efficiency package option indicates in lighting fixture schedule if lamps In fixtures have efficacy rating of 60 lumens per watt or more.Calculate percentage of fixtures with: lamps that have this efficacy rating i(min 05% to comply wlth'opljon). NR c:405:9.2 Escalators and moving walks Lighting Power Calculation'- India 6 compliance path taken tzk C405,4.2.1 Building Area Method Complete required compliance forms - proposed wattage per bullding.ere. dotes riot ek(eed rneximunn allowed wMtege per building area. Identify locations of building areas on plans indicate all one-way dcwn or reversible escalators are provided with 'a vaiiabie frequency regenerative drive Yea C405:d:2:2 Space-By?Spaee Method Complete required compliance forms - total preposed wattage does not exceed maximum allowed wattage: Identify locations of space types on plans, including; retail die>play areas, lobby art & exhlbltdisptay+areas. and ceiling heights as applicable Identifyall controlled and uncontrolled receptabtee-on electrical plans in cads space in Which they.are required: inelude recepteole Ganfiguratlonstieh as spaeing betweencontrolied uncontrolled, duplex devices. etc; NA 0448,3 Reduc$d lighting power density To comply with additional efficiency package option, demonstrate In compliance forms' that total connected interior' lighting wattage Is 75% less than the total maximum allowed lighting wattage via BuirdingiArea Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY- NA 0405,5;2: Total connected exterior lighting power Include all luminaires. in lighting fixture schedule; indicate fixture types. lamps. ballasts. and manufacturer's rated watts per fixture; Identify exterior: applications eligible for lighting power exemption on plane and In compliance forms: indicate exceptiem applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; Include exception claimed for each iieture or group,, of Fixtures under exception category. NA Table C405,6.2(t) Exterior lighting zone Indlcatebuilding exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior buildingFor grounds lighting building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated tamp effioany (in Mulatto per watt) in' fixture schedule NA C405,5.2' Exterior lighting power ea1aulatione Complete required compliance form --proposed wattage for • exterior lighting plus base • site allowed does not excited maximum allowed 2 1 I Irl 2016 aslrington;S ft Qtcr and; : �I ectrlc ail P a erml � � t_Che Checklist, Ila ,. � I�" o � tat e Energycade Cpmptanee permstor eammorale! Buildings Including R2, R3, R4 over 3 mortes and all R120-15 LT C I -ll grtvseaa G U 8t a, Project -Title: Natera 1 Data 8: 3/ 2010 / T , owing The Washington ,.. .. information is necessary to check a' par nit a Kation for =titmice the. " . pRI p with; lighting, motor, and electrical r®quirements' State Energy:Code. Commercial Provisions; In, . the Applicability (yes;ns,na) Cade Section •Gae anent Compliance Information required to permit documents . Location in Documents : runding Department rtment Notes: MOTORS :&TRANSFORMER NA C4t)5,6. Eirrctricel tranformers include electrical transformer schedure en electrical plans: indicate .transformer size, effcianey, or exceptionntake n NA C405,7: Dwelling unit electrical energy consumption. indicate an electrical plant that'eac p h dwelling unit Group: R�2 has a separate electrical energy`rneter'• PA 0405:8 Electric ,motor r efficiency Include all motors, including fractional hp rnotots. in efacto° motor s.chsdule on electrical plans; indicate hp. rpm rated etfeienay, orexcoption applied ' Nn 04.05.9.1 Elevator cabs For lrtrnineitee in'each efevetorcat% provider ale feted average efficacy of combined fixtures that indicates ,effcacy is not less then 15lurnens per watt; Indicate rated watts per foretevatorcab ventllation fans da not exceed;0,33 watts:per ofm;. lnditate automatic.00ntrota.thatde-energize fighting and ventilation fens when elevator Is stopped and unoocupied?for a period of 15 minutes or more NR c:405:9.2 Escalators and moving walks indicate escalators comply with ASME A17,1/CSA 844; automatic controls aro configured to reduce operational speed 10 the, Minimum penteftied Muni* In use trA Cl.9.3 .. Regenerative dr+ytr indicate all one-way dcwn or reversible escalators are provided with 'a vaiiabie frequency regenerative drive ta.A, C405.10and tvantrollyd recapteclES. Identifyall controlled and uncontrolled receptabtee-on electrical plans in cads space in Which they.are required: inelude recepteole Ganfiguratlonstieh as spaeing betweencontrolied uncontrolled, duplex devices. etc; Indicate on lans-whether the method of automatic.control for each Centralia! receptabte zone'Is byoccupentsensoror programmable time -of dey omit* 1f "no" Is selected for any question, provide explanation End of Lighting, Motor & Transformer Permit Documents Checklist EL t RECEM.:C) CITY OF TUKWI!_A AUG 0 8 2018 PERMIT CENTER REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC AUG 2 0 2013 City of Tukwila BUILDING DIVISION C B A ELECTRIC' INC. PO Box 799 Marysville, WA 98270 360-658-0501 www.hmelec,com MAZZETTI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE NREC FORM SHEET NUMBER E0.2 B A 4 4 2 EIVING f1 b WAREN° tan I A I Ian il leil 411011 Irdl -1111 m rmm_wA��l1 1M111'IPI o 1 ►- I � I r �Iil l 'JL! iiC �I II, ;.� OIL—-� ,_ _ 1L2 1 RR JAN 106 107 LUMINAIRE SCHEDULE TYPE WATTS DESCRIPTION RL134W 2'x4' LED LENSED TROFFER, 0-10V DIMMING, 4500 LUMEN, 4000K RL2 15W SIMILAR TO TYPE RL1 EXCEPT WITH INTEGRAL BATTERY BALLAST S1 38W 8' LED STRIP FIXTURE, 0-10V DIMMING, 5000 LUMEN, 4000K X1 4W EXIT SIGN WITH INTEGRAL BATTERY AND SELF DIAGNOSTIC X2 4W EMERGENCY WALL PACK 1 LIGHTING CONTROL NOTES 1. ALL LIGHTING IN WAREHOUSE AREA TO BE DIMMED TO 50% WHEN UNOCCUPIED PER WASHINGTON STATE ENERGY CODE. LOW VOLTAGE SWITCHES IN SPACE TO PROVIDE MANUAL CONTROL OF LIGHTING. FLOOR PLAN -LIGHTING E1.0 SCALE: 1/8" = 1'-0" 2 EL13 Ob'to OF TIJKWILA AUG 0 8 2018 PERMIT CENTER GENERAL NOTES 1. ALL LIGHTING SHOWN ON THIS SHEET TO BE CIRCUITED TO PANELBOARD H1, CIRCUIT AS INDICATED ON PLANS. KEYED NOTES 1. DEMOLISH EXISTING LIGHT FIXTURE. 2. REPLACE EXISTING LIGHTING FIXTURE WITH NEW 8" LED STRIP FIXTURE. MODIFY CIRCUITING TO FIXTURES AS INDICATED. MODIFY SWITCHING TO CONTROL ONLY FIXTURES IN THIS SPACE WITH NEW LIGHT SWITCH SHOWN IN SPACE. LIGHT FIXTURE LOCATIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION. LOCATE FIXTURES APPROXIMATELY AS SHOWN AFTER TANKS HAVE BEEN INSTALLED. REVIEWED FOR MPLIANCE WITH NFPA70-NEC AUG 2 0 2018 City o Tukwila BUILDING DIVISION 8 A ELECTRIC INC. PO Bax 799 Marysville, WA 98270 360.658-050'i www.hmelec.com 40N MAZZETTI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE FLOOR PLAN - LIGHTING SHEET NUMBER E1.0 C B A 4 1 3 1 2 4 4 JACKET WATER HEATER 1"C TO REMOTE ANNUNCIATOR 1"C TO ATS CONTROLS BATTERY CHARGER P2-3,5 WP/GFI P2-1 RE OCATAS U IT (E) RECEIVING 121 TER 120 -1P I)P1-34 1I►P1-34 EXISTING GAS UNIT ��•u�1 1-24,26,28 60AS C^; SP1 -36 /GF1 ROOF) Of Aft. 111► • H1-12.14.1 H1-18,20,2 AREHOUSE 120 B 225A ATS (WALL MOUNTED) 75KVA XFMR STORAGE 104 OFFICE LUNCH 103 CENTRAL 011'FICE 101 1 OFFICE 102 4 FLOOR PLAN - POWER SCALE: 1/8" = 1 "-0" REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC AUG 2 0 2010 City of Tukwila BUILDING DIVISION 'ED CI T° OF TUKWILA AUG 0 8 2018 PERMIT CENTER KEYED NOTES 1, WALKER 4000 TWO-COMPARTMENT WIREMOLD INSULATED ON STEEL SUPPORTS AT +6"-0" AFF. 4"H BASKET TRAY INSTALLED 10'-O" AFF. 3. 125KW/156KVA, 480V/272V, 30, 4W DIESEL GENERATOR IN LEVEL II SOUND ATTENUATED WEATHERPROOF ENCLOSURE. WITH INTERVAL 24 HOUR BASE TANK. 4. GENERATOR REMOTE ANNUNCIATOR PANEL. 5. EXTEND EXISTING 1/2"C -2#12+1/112G FROM GAS UNIT HEATER LOCATION TO RELOCATED GAS UNIT HEATER. 6. EXTEND EXISTING RECEPTACLES BACKBOXES SO RECEPTACLE ARE INSTALLED FLUSH WITH NEW FURRED OUT WALL. 7. INTERCEPT AND EXTEND EXISTING PANEL Hi FEEDER. 2 1 1 C B ELECTRIC INC. POBox 799 Marysville, WA 98270 360.658-0501 www.hmelec.com O MAZZETTI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08103/2018 ISSUE CHART Job Number A Drawn Checked Approved TITLE FLOOR PLAN - POWER SHEET NUMBER E2.0 C 4 B A 3 2 2 ©o RECEIVING 121 0 0 1 VESTIBULE 122 1 1 0 D ELEC COMM CLOSET 123 0 WAREHOUSE 120 II: 1 1 I° STORAGE 104 OFFICE OFFICE LUNCH 103 CENTRAL 0 101 ICE OFFICE 4 O FLOOR PLAN -SPECIAL SYSTEMS SCALE: 1/8" = 1'-0" 3 2 <A> ELIBO(o'O RE.0EI IE0 CITY OF TUKWILA AUG 0 8 2018 PERMIT CENTER EVIEWED FOR . . MPLIANCE WITH NFPA 70 o NEC AUG 202010 City of Tukwila BUILDING DIVISION C B A ELECTRIC INC. PO Box 799 Marysville; WA 98270 360.658-0501 www.hmelec.com C� MAZZET11 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzelti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE FLOOR PLAN - SPECIAL SYSTEMS SHEET NUMBER E2.1 C B A 4 3 2 1 FAULT CALCULATIONS - 3-PHASE SYSTEM V� to LinoUthity or Other Sts Quantity LengthPontPt° RMS Fault Value at End Stent Point End Point Voltam aloeg Wire Size Material 7!1000' Point Notes --- Util XFMR --- --- --- --- --- --- --- --- 25,000 Util XFMR — ATS 480 25000 3/0 cu steel 0.079 1 265 8,662 ATS — H1 480 8662 3/0 cu steel 0.079 1 10 8,453 H1 — PRIM T-75KVA 480 8453 1/0 cu steel 0.12 1 8 8,213 PRIM T-75KVA — SEC T-75KVA 5,084 SEC T-75KVA — P1 208 5084 4/0 Cu steel 0.063 1 8 4,978 Transformer T 75KVA Line to Line PrimaryVoltage E Primary—Side Fault Value Ip = Transformer %Z Zt = Transformer KVA T = Line to Line Secondary Voltage 480 8,213 3.0 75 208 r SPACE 0 200A (O 200A • • O • 200A O r-1 LJ L 4 1 600A BUS TYPICAL UTILITY METERS (• 600A 3P • EXISTING SPACE • • 600A 3P (E) 1200A SERVICE LATERAL 3 (E)2"C-413/0+ 1 #6 225A, 480Y/277V, 4—POLE ATS --\ 2"C-4#3/0+1 #6G--\ (O 200A 3P • • 200A (O 30A (O 40A 3P \• 3P \• 3P I— 7 LJ SPACE 400A BUS I-7 LJ EXISTING 3215 SOUTH 116th BUILDING SERVICE SWBD 1200A, 480Y/277V, 30, 4W ONE -LINE DIAGRAM SCALE: 1/8" = 1'-0" 1 1 IN 1 1 G L__J 125KW/156KVA 480Y/277V GENERATOR 2"C -4#3/0+1#6G 2 480/277 H1 225A 75KVA 208Y/120V P1 225A 208Y/120V P2 225A V#4 1 1/2"C -3#1/0+1#6G 1 1/2"C -4#4/0+1#4G ELL9o'to RECENE0 CITY OF TUKWILA AUG* 0 8 2018 PERMIT CENTER KEYED NOTES 1. REMOVE NEUTRAL TO GROUND BOND AT THE GENERATOR. 2. INTERCEPT AND EXTEND EXISTING FEEDER. —REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC AUG 202010 City of Tukwila BUILDING DIVISION C B A ELECTRIC INC. PO Box 799 Marysville, WA 98270 360.658-0501 www.hmetec.com or MAZZE7T1 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE ONE -LINE DIAGRAM SHEET NUMBER E3.0 C B A 4 4 VOLTS (L -L): PHASE: WIRES: OPTIONS: 480V (N) PANELBOARD: PANEL TYPE MOUNTING: ENCLOSURE FED FROM: NORMAL H1 MSB: BUS RATING: AIC RATING: LOCATION: MLO CKT 3 SURFACE 225A 4 NEMA 1 14,000 AIC FEED THROUGH MAIN SWBD LOAD TYPE DESCRIPTION NOTES CKT CKT DESCRIPTION NOTES LOAD TYPE LOAD (KVA) OC DEVICE PHASE OC DEVICE LOAD (KVA) LOAD TYPE DESCRIPTION BITES CKT AMPS POLES AMPS POLES 1 HEAT PUMP - PRIVATE OFFICES 3 7 1.50 20 3 A 125 3 12.18 2 PANEL P1 7 2 3 - 5 7 1.50 B 12.58 B (VIA 75 KVA XFMR) 7 4 5 - 7 7 1.50 C 11.72 20 - A 6 7 LIGHTS - WAREHOUSE 2 1 0.50 20 1 A 20 1 0.50 1 LIGHTS - OFFICE 20 8 9 WATER HEATER EWH-1 2 7 9.00 40 1 B 20 1 0.50 1 LIGHTS - OFFICE B 10 11 HEAT PUMP - MAIN AREA 2 7 1.50 20 3 C 60 3 13.85 7 RTU -1 A 12 13 - 3 7 1.50 A 13.85 7 - 20/20 14 15 - 1 7 1.50 B 13.85 7 - INSTA HOT / OFFICE RECEPTS 16 17 PANEL P2 20/20 1 6.87 50 3 C 60 3 16 RTU -2 1 18 19 VIA XFMR 20/20 1 6.56 A 1 0.36 - 1 20 21 - REFRIGERATOR 21 6.56 B 20 1 - 1 22 23 SPARE C.B. SPACE ONLY 20 20 3 C 15 3 0.30 3 PUMP SP -i (1/2 HP) 1 24 25 - SPACE ONLY 22 A 0.30 3 - 0.36 26 27 - 1 A B 0.30 3 - 25 28 29 WATER HEATER EWH-2 1.00 7 9.00 40 1 C 20 1 2.57 1 LTG - WHSE, REC, VEST, ELEC 27 30 LOAD TYPE (NUMBER) LOAD TYPE (DESCRIPTION) THIS PANEL: H1 SUB -FEED BREAKER: P1 SUB -FEED BREAKER: FEED THROUGH LUGS: TOTAL CONNECTED LOAD (KVA) DEMAND FACTOR: (NEC CODE SECTION) 1 2 3 Lighting Receps Motors 4.07 0.00 0.00 0.00 8.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 KVA PER PHASE 7 8 Equip Imaging Total 68.55 0.00 73.52 26.47 0.00 36.48 0.00 0.00 0.00 0.00 0.00 0.00 KVA KVA AMPS # OF KITCHEN EQUIP.: # OF ELEVATORS: # OF IMAGING EQUIP: 0 1 A B C 36.89 45.79 47.31 5 6 L. Mot. Kitch Elevator 0.90 0.00 0.00 1.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.07 8.88 0.90 1.13 0.00 0.00 95.02 0.00 110.00 1.25 50%>10kVA 1.00 1.25 1.00 1.00 1.00 NEC (220.56) (620.12) (517.73(A)(2)) TOTAL DESIGN LOAD (KVA) 5.09 8.88 0.90 1.41 0.00 0.00 95.02 0.00 TOTAL DESIGN LOAD (AMPS) NOTES: 1.) NON -COINCIDENT LOAD WITH RTU- 1 2.) 3.) 111.30 133.87 29 0 0 2 2 VOLTS (L -L): PHASE: WIRES: OPTIONS: 208V (N) PANELBOARD: PANEL TYPE: MOUNTING: ENCLOSURE: FED FROM: LUGS NORMAL P1 MCB: BUS RATING: AIC RATING: LOCATION: 225A /3P CKT 3 SURFACE 225A 4 NEMA 1 10,000 AIC FEED THROUGH Hl VIA XFMR LOAD TYPE DESCRIPTION NOTES CKT CKT DESCRIPTION NOTES LOAD TYPE LOAD (KVA) OC DEVICE PHASE OC DEVICE LOAD (KVA) LOAD TYPE DESCRIPTION NOTES CKT AMPS POLES AMPS POLES 1 SPACE ONLY 3 JACKET WATER HEATER 7 1.00 A 2 B 30 2 SPACE ONLY 7 2 3 SPACE ONLY 5 - 7 1.00 B 2.00 7 SERVER UPS SPACE ONLY 7 4 5 SPACE ONLY 0.18 20 1 A 20 C 0.36 2 RECEPT - WIREMOLD SPACE ONLY 9 6 7 EXISTING CIRCUIT 0.80 7 1.00 20 3 A 0.36 2 RECEPT - WIREMOLD (FUTURE) SPACE ONLY 11 8 9 - 0.80 7 1.00 B 20 1 0.36 2 SPACE ONLY 10 11 - 7 1.00 C 1 A 20 1 SPACE ONLY 3 12 13 BATHROOMS / WARE RECEPTS 15 7 1.00 20/20 1 A 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 14 15 INSTA HOT / OFFICE RECEPTS 17 7 1.50 20/20 1 B 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 16 17 HOT WATER TANK / OFFICE RECEPTS 19 7 1.00 20/20 1 C 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 18 19 REFRIGERATOR 21 7 0.87 20 1 A 1 B 20 1 SPACE ONLY 20 21 STORAGE ROOM 23 2 0.36 20 1 B 1 C 20 1 SPACE ONLY 22 23 KITCHEN RECEPTS 25 2 0.36 20 1 C 1 A - SPACE ONLY 24 25 WAREHOUSE HEAT/RECEPT 27 7 1.00 20 1 A 1 B - - SPACE ONLY 26 27 ROOF RECEPTS 29 2 0.36 15 1 B 1 C - - SPACE ONLY 28 29 OFFICE RECEPTS 31 2 1.08 20 1 C 1 A - - SPACE ONLY 30 31 WAREHOUSE RECEPTS 33 2 1.08 20/20 1 A - B - - SPACE ONLY 32 33 COPIER 35 7 1.00 20 1 B 20 1 1.44 2 RECEPT - WAREHOUSE 34 35 SERVER 7 1.00 20 1 C 20 1 0.36 2 RECEPT - ROOF TOTAL DESIGN LOAD (KVA) 0.00 2.76 0.00 1.41 0.00 0.00 16.10 0.00 20.27 KVA 36 37 SPACE ONLY 3.) # OF IMAGING EQUIP: 0 20 1 A 20 1 SPACE ONLY 38 39 SPACE ONLY 20 1 B 20 1 SPACE ONLY 40 41 SPACE ONLY 20 1 C 20 1 SPACE ONLY 42 LOAD TYPE (NUMBER) LOAD TYPE (DESCRIPTION) THIS PANEL: P1 SUB -FEED BREAKER: FEED THROUGH LUGS: P2 TOTAL CONNECTED LOAD (KVA) DEMAND FACTOR: (NEC CODE SECTION) 1 2 3 Lighting Receps Motors 0.00 6.12 0.00 0.00 0.00 0.00 0.00 2.76 0.00 CVA PER PHASE 7 8 Equip Imaging Totol 10.37 0.00 16.49 0.00 0.00 0.00 16.10 0.00 19.99 KVA KVA AMPS # OF KITCHEN EQUIP.: # OF ELEVATORS: # OF IMAGING EQUIP: 0 A B C 12.18 12.58 11.72 5 6 L. Mot. Kitch Elevator 0.00 0.00 0.00 0.00 0.00 0.00 1.13 0.00 0.00 0.00 8.88 0.00 1.13 0.00 0.00 26.47 0.00 36.48 1.25 50%>IOkVA 1.00 1.25 1.00 1.00 1.00 NEC (220.56) (620.12) (517.73(A)(2)) TOTAL DESIGN LOAD (KVA) 0.00 8.88 0.00 1.41 0.00 0.00 26.47 0.00 TOTAL DESIGN LOAD (AMPS) NOTES: 1.) 2.) 3.) 36.76 102.04 0 0 (N) PANELBOARD: P2 VOLTS (L -L): 208V PANEL TYPE: NORMAL MOB: MLO PHASE: 3 MOUNTING: SURFACE BUS RATIN: 225A WIRES: 4 ENCLOSURE: NEMA 1 AIC RATING: 10,000 AIC FED FROM: P1 LOCATION: OPTIONS: CKT DESCRIPTION NOTES LOAD 'TYPE LOAD (I(VA) OC DEVICE PHASE 00 DEVICE LOAD (INA) LOAD TYPE DESCRIPTION NOTES CKT AMPS P LES AMPS POLES 1 BATTERY CHARGER 7 0.50 20 1 A 20 1 1.50 2 SERVER RACK 2 3 JACKET WATER HEATER 7 1.00 20 2 B 30 2 2.00 7 SERVER UPS 4 5 - 7 1.00 C 2.00 7 SERVER UPS 6 7 RECEPT - GENERATOR 2 0.18 20 1 A 20 1 0.36 2 RECEPT - WIREMOLD 8 9 FREEZER EQUIP 7 0.80 20 1 B 20 1 0.36 2 RECEPT - WIREMOLD (FUTURE) 10 11 FREEZER EQUIP 7 0.80 20 1 C 20 1 0.36 2 RECEPT - WIREMOLD (FUTURE) 12 13 FREEZER EQUIP 7 0.80 20 1 A 20 1 1.13 3 TRANSFER FAN TF -1 (3/4HP) 14 15 FREEZER EQUIP 7 0.80 20 1 B 20 1 SPARE C.B. 16 17 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C 20 1 SPARE C.B. 18 19 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A 20 1 SPARE C.B. 20 21 FREEZER EQUIP (FUTURE) 7 0.80 20 1 B 20 1 SPARE C.B. 22 23 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C 20 1 SPARE C.B. 24 25 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A - SPACE ONLY 26 27 FREEZER EQUIP (FUTURE) 7 0.80 20 1 B - - SPACE ONLY 28 29 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C - - SPACE ONLY 30 31 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A - - SPACE ONLY 32 33 SPACE ONLY - - B - - SPACE ONLY 34 35 SPACE ONLY - - C - - SPACE ONLY 36 KVA PER PHASE A B C 6.87 6.56 6.56 LOAD TYPE (NUMBER) 1 2 3 5 6 7 8 LOAD TYPE (DESCRIPTION) Lighting Receps Motors L. Mot. Kitch Elevator Equip Imaging Totol THIS PANEL: P2 0.00 2.76 0.00 1.13 0.00 0.00 16.10 0.00 19.99 SUB -FEED BREAKER: 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 FEED THROUGH LUGS: 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOTAL CONNECTED LOAD (KVA) 0.00 2.76 0.00 1.13 0.00 0.00 16.10 0.00 19.99 KVA GENERAL NOTES DEMAND FACTOR:1.25 50%>14kVA 1.00 1.25 1.00 1.00 1.00 NEC 1. X (NEC CODE SECTION) (220.56) (620.12) (517.73(A)(4) X TOTAL DESIGN LOAD (KVA) 0.00 2.76 0.00 1.41 0.00 0.00 16.10 0.00 20.27 KVA TOTAL DESIGN LOAD (AMPS) 56.27 AMPS NOTES: 1.) # OF KITCHEN EQUIP.: 0 2.) # OF ELEVATORS: 0 3.) # OF IMAGING EQUIP: 0 2 REQ CITY OF TlJKWiL.r* AUG08 2018 PERMIT CENTEE, REVIEWED .FOR COMPLIANCE WITH NFPA 70 o NEC AUG 202010 City of Tukwila BUIL M IN c DIVISION C B A ELECTRIC: INC. PO Box 799 Marysville, WA 98270 360-658.0501 www.hmelec.com CN MAZZETI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mazzetticom Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE PANEL SCHEDULES SHEET NUMBER E3.1 ELECTRICAL SYMBOL SCHEDULE SYMBOLS OXYGEN SYMBOLS LIGHTING SYMBOLS NOTES )J M LED, SURFACE OR RECESSED LIGHT FIXTURE AND OUTLET BOX, NORMAL ® 02 DEFICIENCY BEACON 18" AFF 0 9 WALL MOUNTED LIGHT FIXTURE AND OUTLET BOX, NORMAL HA 02 CONTROLLER 1 1 ►�� LED STRIP; SURFACE, RECESSED OR SUSPENDED LIGHT FIXTURE, NORMAL G CEILING 'E' STEP LIGHT PHOTOELECTRIC SMOKE DETECTOR D -o -Q AREA LIGHTING POLE WITH FIXTURE(S) MANUAL MOTOR STARTER WITH THERMAL OVERLOAD •Q FLOOD LIGHTING FIXTURE VARIABLE FREQUENCY DRIVE _2_2.42_ LIGHTING TRACK WITH FIXTURES; LENGTH AS SHOWN ON PLANS F EQUIPMENT CONNECTION EMERGENCY BATTERY UNIT u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE ® -® EXIT SIGN, SINGLE FACE, CEILING OR WALL MOUNTED; ARROWS AND FACE AS SHOWN ON PLANS e „e EXIT SIGNCES, DOASUBLESHOWNOFACE, N PLCEILINGANS OR WALL MOUNTED; ARROWS TRANSFORMER 0 22 Y411 i T ABBREVIATION AFF ABOVE FINISHED FLOOR E EXISTING DRY CLOTHES DRYER FACP FIRE ALARM CONTROL PANEL HRS HORSE RATED SWITCH PROJ PROJECTOR REF REFRIGERATOR ICE ICE MACHINE MS MOTORIZED SCREEN MW MICROWAVE OVEN NIC NOT IN CONTRACT VM VENDING MACHINE WM WASHING MACHINE SYMBOLS OXYGEN SYMBOLS NOTES PUSH BUTTON LD2 SHUTDOWN MOTOR OUTLET D ® 02 DEFICIENCY BEACON 18" AFF 0 02 DEFICIENCY CENSOR WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN HA 02 CONTROLLER MOTOR STARTER ►_+ SYMBOLS POWER SYMBOLS NOTES 0 MOTOR OUTLET 1 VOICE/DATA OUTLET, RING AND PULL STRING TO ACCESIBLE CEILING FUSED DISCONNECT SWITCH SWITCH XX/XX/XX = AMP SWITCH/POLES/AMP FUSE 18" AFF CP HEAVY DUTY NON-FUSED DISCONNECT SWITCH SWITCH XX/XX = AMP SWITCH/POLES WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN G MOTOR STARTER N/A ►�� DATA OUTLET, CEILING MOUNTED G CEILING N/A COMBINATION MOTOR STARTER PHOTOELECTRIC SMOKE DETECTOR ►tel ST MANUAL MOTOR STARTER WITH THERMAL OVERLOAD 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET REMOTE ANNUNCIATOR VARIABLE FREQUENCY DRIVE -® WE F EQUIPMENT CONNECTION AUTOMATIC TRANSFER SWITCH u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE 120V, DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED TiKVA_r "41.1Y TRANSFORMER 0 22 Y411 i T 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED TRANSFORMER 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED 224) p STATIONARY CIRCUIT BREAKER; RATING AS SHOWN ON PLANS S <<"No>> DRAWOUT CIRCUIT BREAKER; RATING AS SHOWN ON PLANS DOUBLE POLE SWITCH —oho -1=0 WII N RAND EFU E; RATING AS SHOWN ON PLANS SWITCH CULE S4 —off!'- SWITCH AND FUSE; RATING AS SHOWN ON PLANS SINGLE POLE SWITCH WITH PILOT LIGHT SK AVAILABLE FAULT CURRENT IN AMPERES SD DIMMER SWITCH ® DIMMER SWITCH WITH 3 -WAY SWITCHING I F NORMALLY OPEN CONTACT SM 34 NORMALLY CLOSED CONTACT TIMER SWITCH -0 , JQ JUNCTION BOX -❑Q PUSH BUTTON STATION SOS WALL MOUNTED OCCUPANCY SENSOR W/OVERRIDE SWITCH PHOTOCELL CEILING MOUNTED OCCUPANCY SENSOR PC WALL MOUNTED OCCUPANCY SENSOR TIME CLOCK TC PB CONTROL PANEL FURNISHED WITH EQUIPMENT iZ CP WIRING DEVICE KEYED NOTES THE FOLLOWING NOTATIONS MAY BE USED WITH ANY RECEPTACLE TYPE TO FURTHER DEFINE THE SYMBOL: M = FOR MONITORING EQUIPMENT, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT. 0 = EQUIPMENT SYSTEM RECEPTACLE, PROVIDE SPECIAL LABEL, SEE SPECIFICATIONS. T = TAMPER RESISTANT RECEPTACLE. TV = FOR TELEVISION, COORDINATE MOUNTING HEIGHT WITH TELEVISION. WP= WEATHERPROOF, CORD CAN BE PLUGGED IN WITH COVER CLOSED. USB = USB DUPLEX RECEPTACLE WITH 2 USB PORTS RATED AT 2A MINIMUM AT 5V. THE FOLLOWING NOTATIONS MAY BE USED WITH MOST SWITCH TYPES TO FURTHER DEFINE THE SYMBOL: $ = A LINE THROUGH THE SWITCH SYMBOL MEANS THE DEVICE SHALL BE RED WITH A RED COVER PLATE IF PLASTIC PLATES ARE USED. LIGHTING CONTACTOR 1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE WSEC. 2. AS REQUIRED BY SECTION C405.13 ALL LIGHTING SYSTEMS SHALL BE COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD PARTY AGENCY. 3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON THE PLANS. 4. AS REQUIRED BY SECTION C408.1.3 THE COMMISSIONING DOCUMENTS DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. LC 208V/120V SURFACE MOUNTED PANELBOARD OR TERMINAL CABINET 208v/120v FLUSH MOUNTED PANELBOARD OR TERMINAL CABINET SYMBOLS VOICE AND DATA SYMBOLS BACKBOX MTG. HT. POWER 1 VOICE/DATA OUTLET, RING AND PULL STRING TO ACCESIBLE CEILING G 18" AFF N/A Q WAP WIRELESS DATA PROVIDE ONE CAT6 CABLE TO EACH LOCATION SHOWN G 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET N/A r.„41 DATA OUTLET, CEILING MOUNTED G CEILING N/A SYMBOLS FIRE ALARM SYMBOLS ---- ---- --- 0 HORN/STOBE 120V, CONTROLLED DUPLEX RECEPTACLE OUTLET til 120V, 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET 0 SPEAKER/STOBE 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET 4 0 MANUAL PULL STATION 120V, ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE OUTLET 4 120V, CONTROLLED DOUBLE DUPLEX RECEPTACLE OUTLET CO PHOTOELECTRIC SMOKE DETECTOR is ,o changes es shall be made 120V, ABOVE COUNTER 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET REMOTE ANNUNCIATOR SPECIAL PURPOSE RECEPTACLE, VOLTAGE AND NEMA RECEPTACLE TYPE AS NOTED -® WALL MOUNTED EQUIPMENT CONNECTION F EQUIPMENT CONNECTION SYMBOLS AUDIO/VISUAL SPEAKER SYMBOLS SECURITY CAMERA SYMBOLS WIRING DEVICE SYMBOLS IO 120V, DUPLEX RECEPTACLE OUTLET CONDUIT INSTALLED CONCEALED ABOVE CEILINGS OR IN WALLS IN FINISHED AREAS OR EXPOSED IN UNFINISHED AREAS 120V, A3OVE COUNTER DUPLEX RECEPTACLE OUTLET me 120V, CONTROLLED DUPLEX RECEPTACLE OUTLET til 120V, 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET KEY NOTE TAG 120V, ABOVE COUNTER 5MA GFCI TYPE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA CFCI TYPE DUPLEX RECEPTACLE OUTLET 4 120V, DOUBLE DUPLEX RECEPTACLE OUTLET 9 120V, ABOVE COUNTER DOUBLE DUPLEX RECEPTACLE OUTLET 4 120V, CONTROLLED DOUBLE DUPLEX RECEPTACLE OUTLET 41 120V, 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET is ,o changes es shall be made 120V, ABOVE COUNTER 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET 120V, CONTROLLED 5MA GFCI TYPE DOUBLE DUPLEX RECEPTACLE OUTLET -® SPECIAL PURPOSE RECEPTACLE, VOLTAGE AND NEMA RECEPTACLE TYPE AS NOTED -® WALL MOUNTED EQUIPMENT CONNECTION ® EQUIPMENT CONNECTION G u CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE 120V, DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED 120V, DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED L J 0 22 Y411 i 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, FLOOR MOUNTED c L J 120V, DOUBLE DUPLEX RECEPTACLE OUTLET, CEILING MOUNTED 224) SURFACE RACEWAY - TYPE, OUTLETS, SPACING AND FINISH AS NOTED S SINGLE POLE SWITCH S2 DOUBLE POLE SWITCH S3 3 -WAY POLE SWITCH S4 4 -WAY POLE SWITCH SP SINGLE POLE SWITCH WITH PILOT LIGHT SK SINGLE POLE KEY OPERATED SWITCH SD DIMMER SWITCH SD3 DIMMER SWITCH WITH 3 -WAY SWITCHING SV VARIABLE INTENSITY CONTROL FOR SURGICAL LIGHT SM MANUAL MOTOR STARTER SWITCH W/THERMAL OVERLOAD PROT. ST TIMER SWITCH SLM LOW VOLTAGE MOMENTARY CONTACT SWITCH (TOGGLE STYLE) D PUSH BUTTON SWITCH SOS WALL MOUNTED OCCUPANCY SENSOR W/OVERRIDE SWITCH OS CEILING MOUNTED OCCUPANCY SENSOR OS WALL MOUNTED OCCUPANCY SENSOR P PUSH PLATE (FOR AUTOMATIC DOOR) PB PUSH BUTTON (FOR AUTOMATIC DOOR) iZ PHOTOCELL SWITCH WIRING DEVICE KEYED NOTES THE FOLLOWING NOTATIONS MAY BE USED WITH ANY RECEPTACLE TYPE TO FURTHER DEFINE THE SYMBOL: M = FOR MONITORING EQUIPMENT, COORDINATE MOUNTING HEIGHT WITH EQUIPMENT. 0 = EQUIPMENT SYSTEM RECEPTACLE, PROVIDE SPECIAL LABEL, SEE SPECIFICATIONS. T = TAMPER RESISTANT RECEPTACLE. TV = FOR TELEVISION, COORDINATE MOUNTING HEIGHT WITH TELEVISION. WP= WEATHERPROOF, CORD CAN BE PLUGGED IN WITH COVER CLOSED. USB = USB DUPLEX RECEPTACLE WITH 2 USB PORTS RATED AT 2A MINIMUM AT 5V. THE FOLLOWING NOTATIONS MAY BE USED WITH MOST SWITCH TYPES TO FURTHER DEFINE THE SYMBOL: $ = A LINE THROUGH THE SWITCH SYMBOL MEANS THE DEVICE SHALL BE RED WITH A RED COVER PLATE IF PLASTIC PLATES ARE USED. 2015 WA STATE ENERGY CODE 1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE WSEC. 2. AS REQUIRED BY SECTION C405.13 ALL LIGHTING SYSTEMS SHALL BE COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD PARTY AGENCY. 3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON THE PLANS. 4. AS REQUIRED BY SECTION C408.1.3 THE COMMISSIONING DOCUMENTS DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY. SYMBOLS CONDUIT SYMBOLS NOTES A CONDUIT INSTALLED CONCEALED ABOVE CEILINGS OR IN WALLS IN FINISHED AREAS OR EXPOSED IN UNFINISHED AREAS 15ONG _ _ _ _ CONDUIT INSTALLED BELOW FINISHED FLOOR OR BELOW GRADE KEY NOTE TAG INDICATES CONDUIT TURNING UP --o INDICATES CONDUIT TURNING DOWN —• DETAIL REFERENCE BUBBLE CONDUIT STUBBED OUT WITH BUSHING DETAIL NUMBER REVISIONS is ,o changes es shall be made CONDUIT STUBBED OUT AND CAPPED E1.1 FLEXIBLE CONDUIT WITH SINGLE POINT OF CONNECTION AT ELECTRICAL EQUIPMENT SHEET BEARING DETAIL of rrb1^"t 4 <thr.rot prior 1-,,,.„„„;11.3 R sr rtin) GROUNDING CONDUCTOR MOTOR DESIGNATION TAG I:Liz"`° p,s ctzl y =luta G '--"-'1 CONDUIT HOMERUN; ROUTE TO PANELBOARD, CABINET, OR TERMINAL BOARD INDICATED, AND TERMINATE CONDUCTORS TO CIRCUIT OVER CURRENT PROTECTIVE DEVICE SYMBOLS DESIGNATION SYMBOLS NOTES A COLUMN LINE 15ONG FEEDER DESIGNATION TAG KEY NOTE TAG A DETAIL REFERENCE BUBBLE DETAIL NUMBER REVISIONS is ,o changes es shall be made to the scope approval of nmtrir on E1.1 SHEET BEARING DETAIL of rrb1^"t 4 <thr.rot prior 1-,,,.„„„;11.3 R sr rtin) MOTOR DESIGNATION TAG I:Liz"`° p,s ctzl y =luta `' a new plan revival fes. ® 0m A 0 22 FIXTURE DESIGNATION UPPER CASE LETTER INDICATES LUMINAIRE TYPE. LOWER CASE LETTER INDICATES SWITCH LEG NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN). 224) NUMBER INDICATES CIRCUIT NUMBER (WHERE SHOWN) DRAWING INDEX E0.1 ELECTRICAL SYMBOL LEGEND AND ABBREVIATIONS E0.2 NREC FORM E1.0 FLOOR PLAN - LIGHTING E2.0 FLOOR PLAN - POWER E2.1 FLOOR PLAN - SPECIAL SYSTEMS E3.0 ONE -LINE DIAGRAM E3.1 PANEL SCHEDULES - 4 1 3 1 2 SEPA,TE PERMIT t-QU1RED FOR: 4rMechanicnf 0 Electrical L'Plumbing C1 as Piping - City of Tukwila B0_ `%rn DIVISION .01111 FILE COPY Permit No. ()q° Plan roviaw cpproval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt Of approved Raid Copy and conditions is acknowledged: Date: 4/ia/isr City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA. AUG 082018 PERMIT CENTER REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC AUG 202010 C of.Tukwila '._ION C B A ELECTRIC INC. PO Box 799 Marysville, WA 98270 360-658-0501 www.hmelec.c•orrl ‘Ao MAZZED 19203 36th Ave W. Suite 200 Lynnwood. WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 1 16th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE ELECTRICAL SYMBOL LEGEND AND ABBREVIATIONS SHEET NUMBER E0.1 B A 4 4 2 EIVING f1 b WAREN° tan I A I Ian il leil 411011 Irdl -1111 m rmm_wA��l1 1M111'IPI o 1 ►- I � I r �Iil l 'JL! iiC �I II, ;.� OIL—-� ,_ _ 1L2 1 RR JAN 106 107 LUMINAIRE SCHEDULE TYPE WATTS DESCRIPTION RL134W 2'x4' LED LENSED TROFFER, 0-10V DIMMING, 4500 LUMEN, 4000K RL2 15W SIMILAR TO TYPE RL1 EXCEPT WITH INTEGRAL BATTERY BALLAST S1 38W 8' LED STRIP FIXTURE, 0-10V DIMMING, 5000 LUMEN, 4000K X1 4W EXIT SIGN WITH INTEGRAL BATTERY AND SELF DIAGNOSTIC X2 4W EMERGENCY WALL PACK 1 LIGHTING CONTROL NOTES 1. ALL LIGHTING IN WAREHOUSE AREA TO BE DIMMED TO 50% WHEN UNOCCUPIED PER WASHINGTON STATE ENERGY CODE. LOW VOLTAGE SWITCHES IN SPACE TO PROVIDE MANUAL CONTROL OF LIGHTING. FLOOR PLAN -LIGHTING E1.0 SCALE: 1/8" = 1'-0" 2 EL13 Ob'to OF TIJKWILA AUG 0 8 2018 PERMIT CENTER GENERAL NOTES 1. ALL LIGHTING SHOWN ON THIS SHEET TO BE CIRCUITED TO PANELBOARD H1, CIRCUIT AS INDICATED ON PLANS. KEYED NOTES 1. DEMOLISH EXISTING LIGHT FIXTURE. 2. REPLACE EXISTING LIGHTING FIXTURE WITH NEW 8" LED STRIP FIXTURE. MODIFY CIRCUITING TO FIXTURES AS INDICATED. MODIFY SWITCHING TO CONTROL ONLY FIXTURES IN THIS SPACE WITH NEW LIGHT SWITCH SHOWN IN SPACE. LIGHT FIXTURE LOCATIONS TO BE FIELD VERIFIED PRIOR TO INSTALLATION. LOCATE FIXTURES APPROXIMATELY AS SHOWN AFTER TANKS HAVE BEEN INSTALLED. REVIEWED FOR MPLIANCE WITH NFPA70-NEC AUG 2 0 2018 City o Tukwila BUILDING DIVISION 8 A ELECTRIC INC. PO Bax 799 Marysville, WA 98270 360.658-050'i www.hmelec.com 40N MAZZETTI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE FLOOR PLAN - LIGHTING SHEET NUMBER E1.0 C B A 4 1 3 1 2 4 4 JACKET WATER HEATER 1"C TO REMOTE ANNUNCIATOR 1"C TO ATS CONTROLS BATTERY CHARGER P2-3,5 WP/GFI P2-1 RE OCATAS U IT (E) RECEIVING 121 TER 120 -1P I)P1-34 1I►P1-34 EXISTING GAS UNIT ��•u�1 1-24,26,28 60AS C^; SP1 -36 /GF1 ROOF) Of Aft. 111► • H1-12.14.1 H1-18,20,2 AREHOUSE 120 B 225A ATS (WALL MOUNTED) 75KVA XFMR STORAGE 104 OFFICE LUNCH 103 CENTRAL 011'FICE 101 1 OFFICE 102 4 FLOOR PLAN - POWER SCALE: 1/8" = 1 "-0" REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC AUG 2 0 2010 City of Tukwila BUILDING DIVISION 'ED CI T° OF TUKWILA AUG 0 8 2018 PERMIT CENTER KEYED NOTES 1, WALKER 4000 TWO-COMPARTMENT WIREMOLD INSULATED ON STEEL SUPPORTS AT +6"-0" AFF. 4"H BASKET TRAY INSTALLED 10'-O" AFF. 3. 125KW/156KVA, 480V/272V, 30, 4W DIESEL GENERATOR IN LEVEL II SOUND ATTENUATED WEATHERPROOF ENCLOSURE. WITH INTERVAL 24 HOUR BASE TANK. 4. GENERATOR REMOTE ANNUNCIATOR PANEL. 5. EXTEND EXISTING 1/2"C -2#12+1/112G FROM GAS UNIT HEATER LOCATION TO RELOCATED GAS UNIT HEATER. 6. EXTEND EXISTING RECEPTACLES BACKBOXES SO RECEPTACLE ARE INSTALLED FLUSH WITH NEW FURRED OUT WALL. 7. INTERCEPT AND EXTEND EXISTING PANEL Hi FEEDER. 2 1 1 C B ELECTRIC INC. POBox 799 Marysville, WA 98270 360.658-0501 www.hmelec.com O MAZZETTI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08103/2018 ISSUE CHART Job Number A Drawn Checked Approved TITLE FLOOR PLAN - POWER SHEET NUMBER E2.0 C 4 B A 3 2 2 ©o RECEIVING 121 0 0 1 VESTIBULE 122 1 1 0 D ELEC COMM CLOSET 123 0 WAREHOUSE 120 II: 1 1 I° STORAGE 104 OFFICE OFFICE LUNCH 103 CENTRAL 0 101 ICE OFFICE 4 O FLOOR PLAN -SPECIAL SYSTEMS SCALE: 1/8" = 1'-0" 3 2 <A> ELIBO(o'O RE.0EI IE0 CITY OF TUKWILA AUG 0 8 2018 PERMIT CENTER EVIEWED FOR . . MPLIANCE WITH NFPA 70 o NEC AUG 202010 City of Tukwila BUILDING DIVISION C B A ELECTRIC INC. PO Box 799 Marysville; WA 98270 360.658-0501 www.hmelec.com C� MAZZET11 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzelti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE FLOOR PLAN - SPECIAL SYSTEMS SHEET NUMBER E2.1 C B A 4 3 2 1 FAULT CALCULATIONS - 3-PHASE SYSTEM V� to LinoUthity or Other Sts Quantity LengthPontPt° RMS Fault Value at End Stent Point End Point Voltam aloeg Wire Size Material 7!1000' Point Notes --- Util XFMR --- --- --- --- --- --- --- --- 25,000 Util XFMR — ATS 480 25000 3/0 cu steel 0.079 1 265 8,662 ATS — H1 480 8662 3/0 cu steel 0.079 1 10 8,453 H1 — PRIM T-75KVA 480 8453 1/0 cu steel 0.12 1 8 8,213 PRIM T-75KVA — SEC T-75KVA 5,084 SEC T-75KVA — P1 208 5084 4/0 Cu steel 0.063 1 8 4,978 Transformer T 75KVA Line to Line PrimaryVoltage E Primary—Side Fault Value Ip = Transformer %Z Zt = Transformer KVA T = Line to Line Secondary Voltage 480 8,213 3.0 75 208 r SPACE 0 200A (O 200A • • O • 200A O r-1 LJ L 4 1 600A BUS TYPICAL UTILITY METERS (• 600A 3P • EXISTING SPACE • • 600A 3P (E) 1200A SERVICE LATERAL 3 (E)2"C-413/0+ 1 #6 225A, 480Y/277V, 4—POLE ATS --\ 2"C-4#3/0+1 #6G--\ (O 200A 3P • • 200A (O 30A (O 40A 3P \• 3P \• 3P I— 7 LJ SPACE 400A BUS I-7 LJ EXISTING 3215 SOUTH 116th BUILDING SERVICE SWBD 1200A, 480Y/277V, 30, 4W ONE -LINE DIAGRAM SCALE: 1/8" = 1'-0" 1 1 IN 1 1 G L__J 125KW/156KVA 480Y/277V GENERATOR 2"C -4#3/0+1#6G 2 480/277 H1 225A 75KVA 208Y/120V P1 225A 208Y/120V P2 225A V#4 1 1/2"C -3#1/0+1#6G 1 1/2"C -4#4/0+1#4G ELL9o'to RECENE0 CITY OF TUKWILA AUG* 0 8 2018 PERMIT CENTER KEYED NOTES 1. REMOVE NEUTRAL TO GROUND BOND AT THE GENERATOR. 2. INTERCEPT AND EXTEND EXISTING FEEDER. —REVIEWED .FOR COMPLIANCE WITH NEPA 70 - NEC AUG 202010 City of Tukwila BUILDING DIVISION C B A ELECTRIC INC. PO Box 799 Marysville, WA 98270 360.658-0501 www.hmetec.com or MAZZE7T1 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mozzetti.com Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE ONE -LINE DIAGRAM SHEET NUMBER E3.0 C B A 4 4 VOLTS (L -L): PHASE: WIRES: OPTIONS: 480V (N) PANELBOARD: PANEL TYPE MOUNTING: ENCLOSURE FED FROM: NORMAL H1 MSB: BUS RATING: AIC RATING: LOCATION: MLO CKT 3 SURFACE 225A 4 NEMA 1 14,000 AIC FEED THROUGH MAIN SWBD LOAD TYPE DESCRIPTION NOTES CKT CKT DESCRIPTION NOTES LOAD TYPE LOAD (KVA) OC DEVICE PHASE OC DEVICE LOAD (KVA) LOAD TYPE DESCRIPTION BITES CKT AMPS POLES AMPS POLES 1 HEAT PUMP - PRIVATE OFFICES 3 7 1.50 20 3 A 125 3 12.18 2 PANEL P1 7 2 3 - 5 7 1.50 B 12.58 B (VIA 75 KVA XFMR) 7 4 5 - 7 7 1.50 C 11.72 20 - A 6 7 LIGHTS - WAREHOUSE 2 1 0.50 20 1 A 20 1 0.50 1 LIGHTS - OFFICE 20 8 9 WATER HEATER EWH-1 2 7 9.00 40 1 B 20 1 0.50 1 LIGHTS - OFFICE B 10 11 HEAT PUMP - MAIN AREA 2 7 1.50 20 3 C 60 3 13.85 7 RTU -1 A 12 13 - 3 7 1.50 A 13.85 7 - 20/20 14 15 - 1 7 1.50 B 13.85 7 - INSTA HOT / OFFICE RECEPTS 16 17 PANEL P2 20/20 1 6.87 50 3 C 60 3 16 RTU -2 1 18 19 VIA XFMR 20/20 1 6.56 A 1 0.36 - 1 20 21 - REFRIGERATOR 21 6.56 B 20 1 - 1 22 23 SPARE C.B. SPACE ONLY 20 20 3 C 15 3 0.30 3 PUMP SP -i (1/2 HP) 1 24 25 - SPACE ONLY 22 A 0.30 3 - 0.36 26 27 - 1 A B 0.30 3 - 25 28 29 WATER HEATER EWH-2 1.00 7 9.00 40 1 C 20 1 2.57 1 LTG - WHSE, REC, VEST, ELEC 27 30 LOAD TYPE (NUMBER) LOAD TYPE (DESCRIPTION) THIS PANEL: H1 SUB -FEED BREAKER: P1 SUB -FEED BREAKER: FEED THROUGH LUGS: TOTAL CONNECTED LOAD (KVA) DEMAND FACTOR: (NEC CODE SECTION) 1 2 3 Lighting Receps Motors 4.07 0.00 0.00 0.00 8.88 0.00 0.00 0.00 0.00 0.00 0.00 0.00 KVA PER PHASE 7 8 Equip Imaging Total 68.55 0.00 73.52 26.47 0.00 36.48 0.00 0.00 0.00 0.00 0.00 0.00 KVA KVA AMPS # OF KITCHEN EQUIP.: # OF ELEVATORS: # OF IMAGING EQUIP: 0 1 A B C 36.89 45.79 47.31 5 6 L. Mot. Kitch Elevator 0.90 0.00 0.00 1.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4.07 8.88 0.90 1.13 0.00 0.00 95.02 0.00 110.00 1.25 50%>10kVA 1.00 1.25 1.00 1.00 1.00 NEC (220.56) (620.12) (517.73(A)(2)) TOTAL DESIGN LOAD (KVA) 5.09 8.88 0.90 1.41 0.00 0.00 95.02 0.00 TOTAL DESIGN LOAD (AMPS) NOTES: 1.) NON -COINCIDENT LOAD WITH RTU- 1 2.) 3.) 111.30 133.87 29 0 0 2 2 VOLTS (L -L): PHASE: WIRES: OPTIONS: 208V (N) PANELBOARD: PANEL TYPE: MOUNTING: ENCLOSURE: FED FROM: LUGS NORMAL P1 MCB: BUS RATING: AIC RATING: LOCATION: 225A /3P CKT 3 SURFACE 225A 4 NEMA 1 10,000 AIC FEED THROUGH Hl VIA XFMR LOAD TYPE DESCRIPTION NOTES CKT CKT DESCRIPTION NOTES LOAD TYPE LOAD (KVA) OC DEVICE PHASE OC DEVICE LOAD (KVA) LOAD TYPE DESCRIPTION NOTES CKT AMPS POLES AMPS POLES 1 SPACE ONLY 3 JACKET WATER HEATER 7 1.00 A 2 B 30 2 SPACE ONLY 7 2 3 SPACE ONLY 5 - 7 1.00 B 2.00 7 SERVER UPS SPACE ONLY 7 4 5 SPACE ONLY 0.18 20 1 A 20 C 0.36 2 RECEPT - WIREMOLD SPACE ONLY 9 6 7 EXISTING CIRCUIT 0.80 7 1.00 20 3 A 0.36 2 RECEPT - WIREMOLD (FUTURE) SPACE ONLY 11 8 9 - 0.80 7 1.00 B 20 1 0.36 2 SPACE ONLY 10 11 - 7 1.00 C 1 A 20 1 SPACE ONLY 3 12 13 BATHROOMS / WARE RECEPTS 15 7 1.00 20/20 1 A 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 14 15 INSTA HOT / OFFICE RECEPTS 17 7 1.50 20/20 1 B 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 16 17 HOT WATER TANK / OFFICE RECEPTS 19 7 1.00 20/20 1 C 20 1 0.36 2 SOUTH WALL RECEPTS (GFCI) 18 19 REFRIGERATOR 21 7 0.87 20 1 A 1 B 20 1 SPACE ONLY 20 21 STORAGE ROOM 23 2 0.36 20 1 B 1 C 20 1 SPACE ONLY 22 23 KITCHEN RECEPTS 25 2 0.36 20 1 C 1 A - SPACE ONLY 24 25 WAREHOUSE HEAT/RECEPT 27 7 1.00 20 1 A 1 B - - SPACE ONLY 26 27 ROOF RECEPTS 29 2 0.36 15 1 B 1 C - - SPACE ONLY 28 29 OFFICE RECEPTS 31 2 1.08 20 1 C 1 A - - SPACE ONLY 30 31 WAREHOUSE RECEPTS 33 2 1.08 20/20 1 A - B - - SPACE ONLY 32 33 COPIER 35 7 1.00 20 1 B 20 1 1.44 2 RECEPT - WAREHOUSE 34 35 SERVER 7 1.00 20 1 C 20 1 0.36 2 RECEPT - ROOF TOTAL DESIGN LOAD (KVA) 0.00 2.76 0.00 1.41 0.00 0.00 16.10 0.00 20.27 KVA 36 37 SPACE ONLY 3.) # OF IMAGING EQUIP: 0 20 1 A 20 1 SPACE ONLY 38 39 SPACE ONLY 20 1 B 20 1 SPACE ONLY 40 41 SPACE ONLY 20 1 C 20 1 SPACE ONLY 42 LOAD TYPE (NUMBER) LOAD TYPE (DESCRIPTION) THIS PANEL: P1 SUB -FEED BREAKER: FEED THROUGH LUGS: P2 TOTAL CONNECTED LOAD (KVA) DEMAND FACTOR: (NEC CODE SECTION) 1 2 3 Lighting Receps Motors 0.00 6.12 0.00 0.00 0.00 0.00 0.00 2.76 0.00 CVA PER PHASE 7 8 Equip Imaging Totol 10.37 0.00 16.49 0.00 0.00 0.00 16.10 0.00 19.99 KVA KVA AMPS # OF KITCHEN EQUIP.: # OF ELEVATORS: # OF IMAGING EQUIP: 0 A B C 12.18 12.58 11.72 5 6 L. Mot. Kitch Elevator 0.00 0.00 0.00 0.00 0.00 0.00 1.13 0.00 0.00 0.00 8.88 0.00 1.13 0.00 0.00 26.47 0.00 36.48 1.25 50%>IOkVA 1.00 1.25 1.00 1.00 1.00 NEC (220.56) (620.12) (517.73(A)(2)) TOTAL DESIGN LOAD (KVA) 0.00 8.88 0.00 1.41 0.00 0.00 26.47 0.00 TOTAL DESIGN LOAD (AMPS) NOTES: 1.) 2.) 3.) 36.76 102.04 0 0 (N) PANELBOARD: P2 VOLTS (L -L): 208V PANEL TYPE: NORMAL MOB: MLO PHASE: 3 MOUNTING: SURFACE BUS RATIN: 225A WIRES: 4 ENCLOSURE: NEMA 1 AIC RATING: 10,000 AIC FED FROM: P1 LOCATION: OPTIONS: CKT DESCRIPTION NOTES LOAD 'TYPE LOAD (I(VA) OC DEVICE PHASE 00 DEVICE LOAD (INA) LOAD TYPE DESCRIPTION NOTES CKT AMPS P LES AMPS POLES 1 BATTERY CHARGER 7 0.50 20 1 A 20 1 1.50 2 SERVER RACK 2 3 JACKET WATER HEATER 7 1.00 20 2 B 30 2 2.00 7 SERVER UPS 4 5 - 7 1.00 C 2.00 7 SERVER UPS 6 7 RECEPT - GENERATOR 2 0.18 20 1 A 20 1 0.36 2 RECEPT - WIREMOLD 8 9 FREEZER EQUIP 7 0.80 20 1 B 20 1 0.36 2 RECEPT - WIREMOLD (FUTURE) 10 11 FREEZER EQUIP 7 0.80 20 1 C 20 1 0.36 2 RECEPT - WIREMOLD (FUTURE) 12 13 FREEZER EQUIP 7 0.80 20 1 A 20 1 1.13 3 TRANSFER FAN TF -1 (3/4HP) 14 15 FREEZER EQUIP 7 0.80 20 1 B 20 1 SPARE C.B. 16 17 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C 20 1 SPARE C.B. 18 19 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A 20 1 SPARE C.B. 20 21 FREEZER EQUIP (FUTURE) 7 0.80 20 1 B 20 1 SPARE C.B. 22 23 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C 20 1 SPARE C.B. 24 25 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A - SPACE ONLY 26 27 FREEZER EQUIP (FUTURE) 7 0.80 20 1 B - - SPACE ONLY 28 29 FREEZER EQUIP (FUTURE) 7 0.80 20 1 C - - SPACE ONLY 30 31 FREEZER EQUIP (FUTURE) 7 0.80 20 1 A - - SPACE ONLY 32 33 SPACE ONLY - - B - - SPACE ONLY 34 35 SPACE ONLY - - C - - SPACE ONLY 36 KVA PER PHASE A B C 6.87 6.56 6.56 LOAD TYPE (NUMBER) 1 2 3 5 6 7 8 LOAD TYPE (DESCRIPTION) Lighting Receps Motors L. Mot. Kitch Elevator Equip Imaging Totol THIS PANEL: P2 0.00 2.76 0.00 1.13 0.00 0.00 16.10 0.00 19.99 SUB -FEED BREAKER: 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 FEED THROUGH LUGS: 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 TOTAL CONNECTED LOAD (KVA) 0.00 2.76 0.00 1.13 0.00 0.00 16.10 0.00 19.99 KVA GENERAL NOTES DEMAND FACTOR:1.25 50%>14kVA 1.00 1.25 1.00 1.00 1.00 NEC 1. X (NEC CODE SECTION) (220.56) (620.12) (517.73(A)(4) X TOTAL DESIGN LOAD (KVA) 0.00 2.76 0.00 1.41 0.00 0.00 16.10 0.00 20.27 KVA TOTAL DESIGN LOAD (AMPS) 56.27 AMPS NOTES: 1.) # OF KITCHEN EQUIP.: 0 2.) # OF ELEVATORS: 0 3.) # OF IMAGING EQUIP: 0 2 REQ CITY OF TlJKWiL.r* AUG08 2018 PERMIT CENTEE, REVIEWED .FOR COMPLIANCE WITH NFPA 70 o NEC AUG 202010 City of Tukwila BUIL M IN c DIVISION C B A ELECTRIC: INC. PO Box 799 Marysville, WA 98270 360-658.0501 www.hmelec.com CN MAZZETI 19203 36th Ave W, Suite 200 Lynnwood, WA 98036 Tel: 425.672.1071 www.mazzetticom Project Number: 186-019 PROJECT Natera 3215 South 116th Street Building 3, Suite 109 Tukwila, WA 98168 CONSTRUCTION SET 08/03/2018 ISSUE CHART Job Number Drawn Checked Approved TITLE PANEL SCHEDULES SHEET NUMBER E3.1