Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL18-0758 - BOEING #13-03 - INSTALL GROUND UNIT GENERATOR AND ANCHOR TO HOUSEKEEPING PAD
BOEING #13-03 10002 E MARGINAL WAY S BLDG 13-03 ELI 8-0758 Parcel No: Address: Project Name: City of Tukwila Deportment of Community Development 6300 SouthcenterBoulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431'3670 Inspection Request Line: 206-438-9350 Web site: http://mnmw.TukvvUaVVA.uov ELECTRICAL PERMIT 0003480021 Permit Number: 10002 E MARGINAL WAY S BLDG 13- Issue Date: 03 Permit Expires On: BOEING #13-03 EL18-0758 9/28/2018 3/27/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Name: Address: BOEING COMPANY THE PDBOX 37O7M/CZO-59PROPERTY TAX DEPT, SEATTLE, WA, 98124 MARTIN PROBST POBOX 37O7 M/C: 46-2O8'SEATTLE, WA, 98124 Phone: (206) 852-4985 SEQUOYAH ELECTRIC LLC (ELECTRICAL) Phone: (425) 814-6000 15135 NE 9ZND5T'REDMOND, WA, 98052-3519 SEQUOEL977S9 Expiration Date: 1/30/2019 '`' DESCRIPTION OF WORK: INSTALL LTP3 PLUS 180KVA 400 HZ GROUND UNIT MOTOR GENERATOR. ANCHOR TO EXISTING HOUSEKEEING PAD PER MFG REQUIREMENTS TO MEET IBC 2015 SEISMIC RATINGS Valuation of single family: $0.0 Valuation of mf/cmm: $66,000.00 Type of Work: REMODEL Fees Collected: $1,61923 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International FueI Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 OH y� Alk I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: /� Print Name: i�l / Gfr'+I Aot Date: / /26' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. f(AA(6 Project No. \,Date Application Accepted: e6 01 Date Application Expires. 0 t t (Fonqffice us only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 0003400021 10002 East Marginal Way South, Tukwila, WA. 91 Tenant Name: The Boeing Company Suite Number: 13-03 PROPERTY OWNER Name: Martin Probst- The Boeing Co Name: The Boeing Company City:Seattle State: WA Zip: 98124 Address: PO Box 3707; MIC 46-208 Email: martin.r.probst@boeing.com City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Martin Probst- The Boeing Co Address: PO Box 3707; M/C 46-208 City:Seattle State: WA Zip: 98124 Phone: (206) 852-4985 Fax: (253) 657-4659 Email: martin.r.probst@boeing.com New Tenant: Floor: 1-3 Yes ELECTRICAL CONTRACTOR INFORMATION Company Name: The Boeing Company Address: PO Box 3707; M/C 46-208 City: Seattle State: WA Zip: 98124 Phone: (206) 852-4985 Fax: (253) 657-4659 Contr Reg No.: --- tcur,INC*294ML Exp Date: 01/18/2019 Tukwila Business License No.; Valuation of Project (contractor's bid price): $ 66,000 Scope of Work (please provide detailed information): Install I,TP3 plus 180 kVA 400 Hz ground unit motor generator Anchor to existing housekeeping pad per MFG requirements to met IBC 2015 seismic ratings. Will service be altered? J Yes Zj No Adding more than 50 amps? IJ Yes Ei No Type of Use: Type of work: O New DAcldition O Low Voltage 0 Generator Property Served by: O Puget Sound Energy 0 Seattle City Light System power for manufacturing and lab work for systems integration. O Service Change O Fire Alarm WAPermit Center‘Applications-Handouts1Perrnit Applications1PDFsTlectrical Permit Application Revised 1-1-17.domt Revised: January 2017 0 Remodel 0 Telecommunication O Tenant Improvement O Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings $83.54 ea ❑ Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $83.54 (no added/altered circuits) ❑ Service change with added/altered circuits $83.54 number of added circuits $12.00 ea ❑ Circuits added/altered without service change $55.69 (up to 5 circuits) ❑ Circuits added/altered without service change $55.69 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $69.62 ❑ Low voltage systems $61.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $66.30 ❑ Temporary service (generator) $82.52 ❑ Manufactured/mobile home service $87.98 (excluding garage or outbuilding) ❑ Carnivals $82.21 Number of concessions $11.02 ea Each ride and generator truck $11.02 ea ***EFFECTIVE JANUARY 1, 2414 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: e3//2"e Print Name: Martin Probst - The Boeing Company Day Telephone: (206) 852-4985 Mailing Address: PO Box 3707; M/C 46-208, Seattle, WA. 98124 City W:\Permit Center \AppliaGans-Hmxbuts\Permit Applications\PDFs\Electncal Permit Application Revised 1-1-17.docx Revised: January 2017 bh Stifle Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK$1,619.23 ACCOUNT I QUANTITY PAID EL18-0758 Address: 10002 E MARGINAL WAY 5 BLDG 13-03 Apn: 0003400021 $1,619.23 Credit Card Fee $47.16 Credit Card Fee R000.369.908.00.00 I 0.00 $47.16 ELECTRICAL $1,511.61 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $1,209.29 PLAN CHECK FEE R000.345.832.00.00 0.00 $302.32 TECHNOLOGY FEE $60.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15305 R000.322.900.04.00 0.00 $60.46 $1,619.23 Date Paid: Friday, August 31, 2018 Paid By: MARTIN PROBST Pay Method: CREDIT CARD 042911 Printed: Friday, August 31, 2018 11:17 AM 1 of 1 SYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/31/2018 11:17:31 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********9321 K TRAN AMOUNT: $1,619.23 APPROVAL CD: 042911 RECORD #: 000 CLERK ID: Rachelle {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 httos://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 8/31/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 08/31/2018 11:17:31 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********9321 K TRAN AMOUNT: $1,619.23 APPROVAL CD: 042911 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://classic.convergepay .com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 8/31/2018 INSPECTION RECORD Retain a copy with permit NSPECTION NO. PERMTT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: el 64 413-0e/ Type of Inspection: ic Address: /000 2,- t . irgi_ Date Date Called: Special Instructions: Date Wanted: a. I 19Y P. • Requester: Phone No: ?a :iiii ?Approved per applicable codes. Corrections required prior to approval. MMENTS: Inspector: Da e: 0/(0q(1 ri REINSPECTIO FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 9. 27 ro 3 ET, ai CR) '5' a, -t9 E ct_ o 00 ° z ro w to o a 3 co • r' a^ a'• • r• P FIT 2- (0_. 13 3 3 r-1. CU ro 5 ro . • 3 to • o Cu 0_ 0 C 0' 0 "• 0 < (D r, 2 5' • 0, 0. a st = E 3 `0' • 0_ 04 • C (0 -o "2 ,7*. 0_ 0. -0 5 a (0 (0 a. ro a. Fir Cr ' 0- 5 0 c 0 ro 5' (r, 0. co 0. -8 8' z co (I) 0 0 c (0 0 0. o m >m co 1= 831N30 IIINInd NJ 00 00 o — K U) —I U) 11 O () a) 0 SI. r —I a m• . a) 0 (DO) Z C O m - I g. —IN m- 0 D 0 X C n< .-•• O 0 —I -0 m • Co 3 -to C re cf -D2. o = 6 7\ 3 Zsi.) .---.: 3 •—• CD 3 0 cr .c.D„ —CD 4 fp 7.• o m Po S 5 iv a) 0 — a) - co 0 — I —CD 7` 0 -IJ' b -o 0 (D 3 ] v -,: * m- Please have the inspector call with questions and 8 uniew Isn) iscioid CERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0758 PROJECT NAME: Boeing #13-03 SITE ADDRESS: 10002 E Marginal Way 5 #13-03 DATE 09/05/18 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 6t) -34-4r Building Division Public Works 1 ri Fire Prevention Structural E Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable Li (no approval/review required) DATE: 09/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) Notation: 10/04/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 Pw 0 Staff Initials: 17J18/2013 SEQUOYAH ELECTRIC LLC Washington State Department of Labor & Industries Tome Espancl Cont act Search L&I Page 1 of 3 'SFAiteti'• A -Z. Index Help My L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing SEQUOYAH ELECTRIC LLC Owner or tradesperson Principals Nichols, David E, PARTNER/MEMBER GHASSEMI, MAHMOOD, PARTNER/MEMBER Angeline, Scott R, PARTNER/MEMBER Jeffrey, Peter Casino, PARTNER/MEMBER Trocano, Rick, PARTNER/MEMBER Nagel, Cheryl L, PARTNER/MEMBER Nichols, Christopher R, PARTNER/MEMBER Doing business as SEQUOYAH ELECTRIC LLC WA UBI No. 602 252 591 15135 NE 92ND ST REDMOND, WA 98052 425-814-6000 KING County Business type Limited Liability Company Governing persons DAVID E NICHOLS MAHMOOD GHASSEMI; License Verify the contractor's active registration /11 Electrical Contractor License specialties GENERAL License no. SEQUOEL977S9 Effective — expiration 01/29/2003— 01/30/2019 Designated administrator Nichols, Christopher ion depending on trade) and any past violations. Active. Meets current requirements. Active. Meets current requirements. License type License no. Electrical Administrator NICHOC•835RE Bond HARTFORD CAS INS CO Bond account no 52BSBAB5541 $4,000.00 Received by L&I Effective date 01/29/2003 01/29/2003 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602252591&LIC=SEQUOEL977S9&SAW= 9/28/2018 SEQUOYAH ELECTRIC LLC Savings No savings accounts during the previo License Violations 6w. period. Infraction no. ELYOD01375 Issue date 06/22/2017 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Covering or concealing installations prior to inspection. Infraction no. ELYOD01374 Issue date 06/22/2017 Violation city REDMOND Type of violation ELECTRICAL CITATION Description Failing to get an inspection or obtain a valid electrical/telecommunications work permit or post a provisional electrical work permit prior to beginning the electrical/telecommunication installation or alteration as referenced in WAC 296-46B-901. Satisfied RCWIWAC 19.28.101 RCW Violation amount $207.00 Satisfied RCW NAC 19.28.101 RCW Violation amount $207.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 061,981-00 Doing business as SEQUOYAH ELECTRIC LLC Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 • Email: ANDN235@lni.wa.gov Track this contractor el Account Is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 01/13/2016 Inspection no. 317937437 Violations Page 2 of 3 Help us improve https://securelni.wa.gov/verify/Detail.aspx?UBI=602252591 &LIC=SEQUOEL977S9&SAW= 9/28/2018 '0 D SL MMAY LAND USE CODE TUKWILA, WASHINGTON ZONING MANUFACTURING INDUSTRIAL CENTER/HEAVY INDUSTRIAL (MIC/H) REPLACED IMPERVIOUS SURFACE: 0 SF (0.00 AC) ESTIMATED EARTHWORK QUANTITIES: CUT 0 CY (0 CY EXPORT) FILL 0 CY (0 CY IMPORT) TOTAL 0 CY (0 CY) POJ CT I aWATI N SCOPE OF WORK: ALL WORK APPLIES TO 13-03 BUILDING: CIVIL: PROVIDE STRUCTURAL ANCHORING FOR 400HZ GENERATORS ELECTRICAL: RE—INSTALL GPU #1 (PROVIDED BY BOEING). INSTALL A SECOND JBT 400HZ 180KVA GROUND POWER UNIT (CPU #2). PROVIDE CONDUIT AND CONDUCTORS FROM PANEL 1D6 TO GPU AND FROM GPU , TO PANEL 1D6-3. PROVIDE 400HZ FEEDER PROTECTION ON EXISTING GENERATOR 1 AND NEW GENERATOR. 2 OUTPUTS IN PANEL 1D6-3 GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO THE WSDOT STANDARD SPEC. 2016 EDITION, CURRENT WSDOT STANDARD PLANS, AND CITY OF TUKWILA REGULATIONS. 2, THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK AND SHALL NOTIFY THE BOEING PROJECT MANAGER OF ALL DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS. 3. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. BOEING CONTACT: SUNG CHO FACILITIES ENGINEER P. 0. BOX 3707, MS 46-87 SEATTLE, WA 98124-2207 TELEPHONE: 206-612-6953 VERTICAL DATUM: NAVD 88 BENCHMARK: CITY OF SEA! I LE SNV-5296 BRASS CAP 25' 5 OF WHEELCHAIR RAMP AT SE CORNER OF INTERSECTION OF E MARGINAL WAY S AND S 96TH PL ELEVATION = 18.14' A BO VC\TY MA 400 NG 10441,, / PO - R SVS 08# J5J/9 BOEING MILITARY FLIC-- CENER 10002 EAST MARGINAL WAY SOUTH TU<WILA, WASHINGTON 98108 PROJECT SITE SI ADDRESS: EAST VARGI\AL WAY SO 'KWILA, WAS-I\GTO\ FROM DOWNTOWN SEAI ILE D❑ 900 u) PROJECT SITE OXBOW :'ISGE EXIT EXIT 158-� 158 MILITARY FLIGHT CENTER OXBOW LOT 4 EXIT 157 EXIT 157 EAST MARGINAL WAY CORPORATE PARK 599 TUKWILA FROM KEI\ & AUBUR 900 99 FROM SEM I LE—TACOMA AIRPORT OXBOW PARKING LOT 3 -V-Lo v \TAL C TES NO SCALE 400H7 GPU PLACEV=\T LOCA NO SCALE IN SET DRAWING # SHEET # DRAWING TITLE REV DATE GENERAL • 13 -003 -GO GO COVER SHEET - 08.10.18 ELECTRICAL • 13-003-E1A E1A ELECTRICAL LEGEND C 08.10.18 « 13-003-E1B E1B NOTES, SYMBOLS AND ABBREVIATIONS - 08.10.18 • 13-003-1E4AR 1E4AR ONE LINE DIAGRAM - 60 HZ POWER (REMOVAL) B 08.10.18 • 13-003-1E4ER 1E4ER ONE LINE DIAGRAM 400 HZ POWER SYSTEM (REMOVAL) E 08.10.18 • 13-003-1E2R 1E2R 480 VOLT MAIN POWER PLAN (REMOVAL) C 08.10.18 • 13-003-1E160R 1E16OR 400HZ & 28V DC POWER PLAN (REMOVAL) D 08.10.18 • 13-003-1E4A 1E4A ONE LINE DIAGRAM - 60 HZ POWER B 08.10.18 • 13-003-1E4B 1E4B ONE LINE DIAGRAM - 60 HZ POWER D 08.10.18 • 13-003-1E4E 1E4E ONE LINE DIAGRAM 400 HZ POWER SYSTEM E 08.10.18 • 13-003-1E2 1E2 480 VOLT MAIN POWER PLAN C 08.10.18 • 13-003-1E9 1E9 GROUNDING C 08.10.18 • 13-003-1E160 1E160 400HZ & 28V DC POWER PLAN D 08.10.18 • 13-003-2E160 2E160 400HZ & 28V DC POWER PLAN F 08.10.18 • 13-003-E5O8 E508 DETAILS D 08.10.18 • 13-003-E524 E524 DETAILS 400HZ & ANTENNA ALARM PANEL E 08.10.18 • 13 -0O3 -E535 E535 LAYOUTS 1ST / 2ND / 3RD FLOORS C 08.10.18 FILE COPY Permit No. E S- 075'6 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Rccoipt of approved Field Copy and conditions is acknowledged: ©y: Date: // / ,, J, ., City of Tukwila BUILDING DIVISION REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division NOTE: Ravisicns will require a new plan submittal and may include aonal plan review fees, SEP, Ai IA I E PERMIT REQUIRED FGR» 1 chanicai 0 Electrical <umbing [- as Piping Ciiy of Tukwila B IILPING DIVISION ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC SEP 2 8 2018 City of ukwila BUILDING DIVISION RECEIVED CITY TY OF TUKVVILA AUG 31 2018 PERMIT CENTER ECA SNE EAND TECHNOLNGINEEOGY CRINGONSU, ILTANTSNC. ELECTRICAL 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.03.18 ff..&171/!s ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. KREISCHER CHECKED B. LESLIE ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED DATE 11.28.16 11.28.16 02.01.17 SU BTITLE COVER SHEET CURRENT REVISION 35379 SYM BO DATE 08.10.18 02.01.17 TITLE GENERAL INCREASE 400HZ POWER SYSTEM 13-YRD .F.0 SHEET GO JOB NO. 35379 COMP NO. DWG NO. —003—GO LGT (LV) 1D5 1D5-1 X1D5 400 HZ DIST. PANEL 1D6-3 FRONT PANEL JETPOWER III 400HZ, 180KVA GPU1I2 (4) 4" TO SUB. 13.01 gtx NOR (4 4 — TO HANDHOLE (FOR COMMUNICATION, LOCATION TBD) 4 2" — TO EMERGENCY POWER SWITCHBOARD AND BUILDING CONTROL (TBD) 4 2" — TO DUMPSTER (REFER TO SHEET E507) (3) 3/4" — TO DUMPSTER (REFER TO SHEET E507) QUI3VVE\T LAYOUT PLA\ FIST FL. ELECTRICAL .00Iv SCALE: 1/4" = 1'-0" WctfriipiQ 1 E2,1 E3,E4A E535 LGT (LV) 2D5-2 2D5-1 2D5 75 X2D6 2D6-1 X2D6-1 2D6 EQUIRME\T LAYOUT SECO\D FLCO =L SCALE: 1/4' = 1'-0" DLA\ -CTS I CAL OOv (2� 2E2,2E3,E4B E535 LGT (LV) 3D5-2 3D5-1 3D5 /3 X3D6 3D6-1 X3D6-1 3D6 EQURVE\T TH I D FLOC) SCALE 1/4" = 1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION SMD TB B REPLACE 400 HERTZ GENERATORS 32317 CASNE JMK CEC 03.14.96 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT C INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG 03.27.18 08.10.18 MffE7 ® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG -0" LAY C J T PLA\ ELECTS I CAL DATE CO 03 v 3E2,3E3,E43 E535 L 3 -EFEH\CE D AWI\GS ► 13-003-S503 G \HAL OTES CO\ STUCTIC \ OTES INSTALL JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT. ANCHOR TO EXISTING HOUSEKEEPING PAD PER MANUFACTURER REQUIREMENTS TO MEET IBC 2015 SEISMIC RATINGS. EL(BO75 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED Wii H COMPLIANCE NEPA 70 - NEC SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVED CiTY OF TUKWII ,, AUG 3 1 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA9H0. (425) 522-1000 wunurecur gnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, 98033 WWW. CASNE. COM NO. 181-085 CHECKED T. BENNETT SUBTITLE LAYOUTS 1ST / 2ND / 3RD FLOORS CURRENT REVISION SYMBOL 35379 C DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE 01.12.96 BUILDING 13-03 INCREASE 400HZ POWER SYSTEM ELECTRICAL ROOMS SHEET E535 JOB NO. MFC -95060 COMP NO. DWG NO. Dev. Center,Wa 13-003—E535 R1 R2 TR SPACE / ENCL1 TB1 (5) DOOR MOUNTED ITEMS: FU1 LI, L2, L3, L4, L5 51, 52, 53, S4 B1 DOOR — INSIDE CABINET — INSIDE 400 HZ AND ANTENNA TRANSMITTER ALARM PANEL SCALE: NONE ALARM PANEL COMPONENT LIST ITEM TAG QTY. DESCRIPTION MANUFACTURER/MODEL R1 1 CONVERTIBLE CONTACT RELAY, (2) 10A CONTACT CARTRIDGES, 120V, ALLEN BRADLY #700—P200B11 R2 1 CONVERTIBLE CONTACT RELAY, (4) 10A CONTACT CARTRIDGES, 120V, ALLEN BRADLY #700—P400B11 TR 1 SOLID STATE TIMING RELAY, 2 NO CONTACTS, 120V, 4 CONTACTS. ALLEN BRADLY #700—RTC00400U1 L2 1 FLASHING PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, RED LENS SQUARE D, CLASS 9001 #KXPAF1R L1,L3,L4 L5 4 PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, GREEN LENS SQUARE ' D, CLASS 9001 #KP1 G31 1 1 L1 LEGEND PLATE, BLACK WITH WITH "POWER ON" SPECIAL MARKINGS SQUARE D, CLASS 9001 #KN399 —"POWER ON" L1,L3,L4 3 PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, GREEN LENS SQUARE D, CLASS 9001 #KP1G31 L6 1 SIGNALING LIGHT, CEILING MOUNTED, 120V, WHITE DOME, STAINLESS STEEL PLATE. EDWARDS #7641-1N5 L7 1 FLASHING LIGHT WITH PROTECTIVE DOME COVER. WALL MOUNTED, 120V, AMBER. EDWARDS #49A—R5 B1 1 PANEL MOUNT BUZZER, 120V. EDWARDS'S LUMATONE OR EQUIVALENT. B2 2 AMBER FLASH BEACON LIGHT WITH SEPERATE HORN. 120V, PIPE MOUNTING, WEATHERPROOF. EDWARDS #94A—N5 FU1 1 FUSEHOLDER FOR 1-1/4"x1/4" FUSE, NEON LAMP INDICATION OF BLOWN FUSE BUSSMANN #HKL—X 51, S2, S4 2 MOMENTARY CONTACT PUSHBUTTON SWITCH, 1 N.O. & 1 N.C. CONTACTS, GREEN BUTTON WITH FULL GUARD SQUARE D, CLASS 9001 #KR1GH13 SYSTEM FAULT 1 FUSE, 1-1/4"x1/4" CERAMIC TUBE, 250 V, 15 AMP, TIME DELAY BUSSMAN #MDA -15 S3 1 ON—OFF SELECTOR SWITCH. SQUARE D, CLASS 9001 SWITCH #D 2SDU 1 O LEGEND #85W2 ENCL1 1 NEMA 1, 16 GAUGE ENCLOSURE WITH WITH ENAMEL MOUNTING PANEL, HINGED DOOR WITH FLUSH HANDLE LATCH, LIGHT BLUE ENAMEL EXTERIOR HOFFMAN "A" SERIES CONTROL ENCLOSURE. SIZE: 12" W X 16" H MINIMUM TB1 6 TERMAINAL STRIP WITH 6 TERMINAL BLOCKS, BARRIER TYPE WITH MARKING STRIP, 25 AMP, SCREW TERMINALS WITH WIRE CLAMPS, #18—#12 AWG WIRE RANGE ALLEN—BRADLEY #1492—HJ86 REVISION BY APPROVED DATE SYM REVISION DOOR — OUTSIDE NAMEPLATE SCHEDULE 400 HZ MG AND ANTENNA ALARM PANEL SCHEMATIC DIAGRAM H WIRE NUMBER DESIGNATION (TYP) R1 L2 (N) N � 81 (30) S3 [17]" ---'RELAY LINE NUMBER L1 400 HZ SYSTEM FAULT INDICATOR 400 HZ SYSTEM FAULT BUZZER (N) "POWER ON" ITEM TAG QTY. SIZE COLOR LINE HR TEXT NOTES FACE TEXT NP -1 1 BLK WHT 1 1/4" 400 HZ & ANTENNA PANEL MOUNT ON FRONT OF PANEL NP -2 1 BLK WHT 1 1/8 FUSE MOUNT ON FRONT OF PANEL 2 1 /8" MDA 15 NP -3 1 GRN WHT 1 1/4" 400 HZ SYSTEM MOUNT ON FRONT OF PANEL NP -4 1 GRN WHT 1 1/8" SYSTEM FAULT ALARM MOUNT ON FRONT OF PANEL NP -5 1 GRN WHT 1 1/8" SYSTEM FAULT MOUNT ON FRONT OF PANEL NP -6 1 GRN WHT 1 1/8" ALARM RESET MOUNT ON FRONT OF PANEL NP -7 1 GRN WHT 1 1 ,> . �1 MOUNT ON FRONT : PANEL NP -8 1 GRN WHT 1 1/8" 400HZ GPU #1 ON MOS T ON FRONT OF P=NEL NP— 9 1 GRN WHT 1 /8" © 400HZ GPU #2 ON MOU - OF P ON FRONT EL NP -10 1 YEL WHT 1 1 , " ,: T , ,. .. M MO . I T ON FRONT OF PANEL NP -11 1 YEL WHT 1 1/8" PUSH TO ACTIVATE MOUNT ON FRONT OF PANEL 2 1/8" PRE—TRANSMISSION WARNING NP -12 1 YEL WHT 1 1/8" ROOF ANTENNA MOUNT ON FRONT OF PANEL 2 1/8" TRANSMITTING SIGNAL NP -13 1 YEL WHT 1 1/8" TRANSMITTING STOP MOUNT ON FRONT OF PANEL BY APPROVED DATE DCN 29 - 400 HZ AND ANTENNA PANEL SMD JK KR 23.8.96 - RECONCILED TO VAULT INCORPORATED CONST. RED -LINES MODIFIED ROOF WARNING LIGHT/HORN J#772575 -LO REPLACE 400 HERTZ GENERATOR 32317 K.DARCY 7/2/97 E INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG 03.27.18 08.10.18 K.DARCY N.MEHTA 7/14/97 CASNE CE 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 8 9 10 11 12 1 6A [8] S4 RESET 0 0 Si SPARE (FIELD INPUT) SPARE (FIELD INPUT) (7) LATCHING RELAY 16 17 18 19 20 21 22 23 24 25 26 27 [8] TR [21] S2 0 10 PRE—TRANSMISSION WARNING 12 R1 14 R2 11 13 [8] 5 11 L5 (N) L6 SPARE SPARE B2 B2 LATCHING TIMER RELAY 8] ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE [21] DRAWN S. DANG DATE CHECKED T. BENNETT -® -0 -o N "GPU #1 ON" PILOT LAMP "GPU #2 ON" PILOT LAMP 9, 16, 25, 27 MG FAULT RESET 4,23 8, 19, 27, 28 28 29 TO ANTENNA TRANSMITTER INPUT INTERLOCK (CONTACT CLOSE TO ENABLE TRANSMITTER TO START). SUBTITLE 19 TR SYMBOLS LEGEND PANEL TERMINAL BLOCK PANEL WIRING FIELD WIRING GENERAL NOTES ALL WIRES TO BE LABELED PER CONNECTED TERMINAL BLOCK NUMBER, UNLESS OTHERWISE INDICATED. REFER TO SHEET 2E60, COL. 3/C FOR LOCATION. REFER TO SHEET 2E60, COL.2/C FOR LOCATION. REFER TO SHEET 3E60, COL. 5/A FOR LOCATION. REFER TO SHEET RFE60, COL. 5/A—B FOR LOCATION. CO\ST CTIO \OT -S PROVIDE UPDATED CONTROL PANEL LABEL WITH GPU #. MATCH EXISTING FONT TYPE, COLOR AND SIZE. PROVIDE CONTROL PANEL LABEL. MATCH EXISTING FONT TYPE, COLOR AND SIZE. RECONNECT EXISTING WIRING TO GROUND POWER UNIT #1 STATUS CONTACTOR. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR DETAILS. CONNECT SPARE WIRING TO GROUND POWER UNIT #2 STATUS CONTACTOR. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR DETAILS. 21 20 EL1B ISSUE FOR CONSTRUCTION AUGUST 10, 2018 DETAILS 400 HZ & ANTENNA ALARM PANEL SPARE 075 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 8 2018 City of •Tukwila BUILDING DIVISION RE-:CEi\r E0 CiTY OF TUKWILJ.\ AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION SYMBOL 35379 DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 SHEET E524 JOB NO. MFC -95060 COMP NO. DWG NO. Dev. Center,Wa 13-03—E524 FINISH FLOOR SLAB 8'-0" MAX EQUAL EQUAL SYMEITRIC H Z' DISCONNECT SWITCH _JUL P3301 HORIZ12—TOTAL ( ) CENTER AT P3000 VERTS 6" CLEAR TRANSFORMER OR DC POWER SUPPLY. 650 LBS MAX WT. (2—TOTAL) P1047 EA END OF EA SLEEPER AT P3301 P3000 SLEEPERS (3) MIN PER UNIT JZ _Z 1" MAX TYP J / // / E534 ABOVE CEILI NOT TO SCALE NON—SECURED AREA WALL P3000 DIAGONAL WITH 3/8" DIA MACHINE SCREW AT EA P3301 HORIZ (6—TOTAL) P3301 HORIZ (12—TOTAL) CENTER AT P3000 VERTS WITH P2484W EA END TYP NOTE: ALL FRAMING COMPONENTS SHALL BE UNISTRUT P1379S CLAMP TYP P3000 VERT TYP P1379S CLAMP EA SIDE FLANGE WIDE FLANGE FLOOR OR ROOF BEAM \G TRANSFORMER & DC POWER SUPPLY SUPPORT m E2 SERIES E508 SECURED AREA TRUSS, BLDG. STEEL, ETC. T&B PART #3122 CONDUIT HANGER (TYPICAL) TYPICAL CONDUIT PASSING THRU PROGRAM BOUNDARY FOR FIRE RATED WALLS, INSTALL 3M #FS 195 FIRE BARRIER ON EACH SIDE OF WALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS BONDING STRAP (2 PLS — TYP) OZ PART #GF19G 1/2"-1" PVC SECTON — EXTEND 3" MINIMUN BEYOND FIRE STOP ASS'Y ON EACH SIDE OF WALL BONDING REQUIRED ON BOTH SIDES OF PVC SECTION TO BUILDING STEEL. EACH SIDE OF PVC SECTION MUST BE BONDED SEPARATELY. #12 AWG MIN. BONDING REQUIRED ON ALL CONDUITS et BONDING WIRE SIZE SHALL BE PER N.E.C. 250-79d. SECURED TO SON -SECURED CONDUIT DETAIL NOT TO SCALE REVISION BY APPROVED DATE SYM 2 P1728 TYP 1" TYP A Lal U P3000 SLEEPER (3) MIN PER TRANSFORMER P3000 WITH P1047 AT EA VERT P2484W TOP AND BOT OF P3000 VERTS NOTES 1. TAKE RESISTANCE MEASUREMENTS BETWEEN EACH CONDUIT AND THE STRUCTURE TO WHICH IT IS BONDED AT, A POINT NEAR EACH BONDING STRAP. RESISTANCE NOT TO EXCEED 0.005 OHMS (5 MILLIOHMS). 4 1 AX 1'-0" P3000 2. RESISTANCE MEASUREMENTS FOR CONDUITS AT ALL BONDING STRAPS TO BE RECORDED AND PROVIDED TO THE BE&CE CONSTRUCTION MANAGER UPON COMPLETION OF INSTALLATION. 3. AS BUILT DRAWINGS SHOWING LOCATION OF ALL BONDING STRAPS TO BE PROVIDED TO THE BE&CE CONSTRUCTION MANAGER UPON COMPLETION OF INSTALLATION. 2E2,2E60,2E1601E508 REVISION APPROVED DATE DISCONNECT SWITCH • • • • r • FINISH FLOOR SLAB P3301 HORIZ TYP (2) AT EA FLUTE P2484W AT EA P3301 P3000 VERT TYP OUTLINE OF TRANSFORMER (NOT SHOWN) 0 0 0 • • r �r i L • • • • P3000 DIAGONAL 3/8" MACHINE SCREW AT EA P3301 (6—PLACES) NOTE: ALL FRAMING COMPONENTS SHALL BE UNISTRUT SECTION r -A - E508 P1379S CLAMP EA SIDE FLANGE TYP P1047 TYP P3000TYP P3301 HORIZ TYP P2484W TYP (24—TOTAL) LEGEND: GENERAL NOTES: REVIEWED WITH COMPLIANCE 70 - NEC SEP 2 8 2018 CONFIGURATION DEPENDENT ON FEEDER CALL OUT ON REFERENCING DRAWING r ECEIti 0 CTYOFTUKWILA 400 HZ SPIRAL WOUND CABLE CONFIGURATION / 3 ISSUED FOR CONSTRUCTION SD TB MOD. E37 PWR. PNL 400HZ 10D1521234 VAVREK REPLACE 400 HERTZ GENERATORS RECORD DRAWING 32317 CASNE 32317 RECONCILED TO VAULT CASNE NO JMK VAVREK 03.14.96 02.15.05 D INCREASE 400HZ POWER SYSTEM 35379 CASNE 08.10.18 FOR REFERENCE ONLY ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY CEC 02.01.17 06.26.17 03.27.18 DEPT. DATE DRAWN S DANG DATE CHECKED T BENNETT ENGINEER S DANG CHECKED T BENNETT SUBTITLE ISSUE FOR CONSTRUCTION AUGUST 10, 2018 DETAILS CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION 35379 SYMBOL 3 DATE 08.10.18 APPROVED J KOKOCZKA APPROVED K RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHEET E508 JOB NO. COMP NO. DWG NO. 13-003—E508 1 CONVENIENCE OUTLETS 400—HZ 2C1-1 Cc 15 2A4-3/1 a 1/2" RAC 30 ALUMINUM CONDUIT 3/4" C., (5) #8 2A4-3/ 190,211D,23 THIS BOX' REPRESENTS THE WORKING 2A4-3 15 X 9 730 SUPPLY NTL -18 THESE WILL BE WALL MOUNTED (NOT UNDERFLOOR) 200 200 3 —11 3/4 CLEARANCE REQ'D BY THE N.E.C. IT MUST NOT BE OCCUDIED BY ANY OTHER EQUI' ACCEPTABLE?? 2D1 1"RAC-4#6, 1118 GRD. 201/26,28,30 D\ 60A/NF UNDERFLOOR J—BOX 7 TYPICAL AIRCRAFT PWR. DISTBN. CTR. CUSTOMER SUPPLIED STINGER CABLE X TO 400 HZ DISTRIBUTION PANEL 106-3. SEE DWG. E4E 400HZ & ANTENNA ALARM PANEL 1/2"C 3#12 400HZ GPU#2 STATUS 1/2"C 3#12 400HZ GPU#1 STATUS 9 MOM 1111111. OWN 1] L 9 F X 0 i D 2D4-1 I9> u Jr SECO\D FLOOR DLA\ SCALE: 1/8' 1/8'=l' (i) Ll 8- 0755 (TE8jH' _COi INPLIA NFPA 70 - NEC SEP 28 2018 City of Tukwila BUILDING DIVISION LEGEND: REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA `'' 20 20 200Y/115 4 5 HUBBELL 3520 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 160 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 +1 ti 28 VDC PANEL. 400 HZ PANEL. GEN ERAL \OTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400HZ HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 400HZ A 0 (LEFT BUS IN PNL) B 0 CENTER BUS IN PNL) C 0 RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN RED BLACK GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. 1 9 > REFER TO SHEETS E512 AND E513 FOR COMPUTER RECEPTACLES AND POWER REQUIREMENTS FOR THIS ROOM. CO\STJCTIO\ \OTES PROVIDE UPDATED ANNUNCIATOR PANEL LABELS. SEE E524 FOR DETAILS. TERMINATE EXISTING SPARE WIRING FOR GPU #2 STATUS. SEE E524 FOR DETAILS. REFERENCE DRAWINGS 13-003-1E160 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 13-003—E524 RECEIVES) MY OF _i UK'vVILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION RECORD DRAWING 32317 B C D E NATO AWACKS INTEG. LAB PROVIDE POWER NATO LAB 13.03.02 MOD. E37 PWR. PNL. 400HZ REPLACE 400HZ GENERATORS 170097-01 792351-00 1001521234 32317 DEH JDH VAVREK CASNE JV AW WHITSON VAVREK CEC 06.19.98 08.12.99 02.14.05 02.01.17 RECONCILED TO VAULT F INCREASE 400HZ POWER SYSTEM 35379 CASNE NO CASNE SHG RM SHG 06.26.17 03.27.18 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN T. BENNETT DATE CHECKED S. DANG ENGINEER SUBTITLE 400 HZ & 28V DC POWER PLAN CURRENT REVISION SYMBOL 35379 DATE 08.10.18 T. BENNETT CHECKED S. DANG APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. A—H/1-7 Dev. Center,Wa SHEET 2E160 JOB NO. MFC -95060 COMP NO. DWG NO. 13-003-2E160 (5) -EC REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND HZ SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA 400 ="' 20 20 200Y/115 4 5 HUBBELL 3520 400 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 400 60 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 400 IV 15 15 115 2 3 HUBBELL 7487 DC 1-0 20 20 28 2 3 HUBBELL 6810 1D i —2/38,40,42 28 VDC PANEL. 400 HZ PANEL. UP TO 2C1-1/9,11,13,1 1 D6-3/ 14a,16b,18t 6# 1 /0+1 /OG(SPIR, L) 1D1-2/32,34,36 ,/ 1D1-2/ a,3b,5 1 11-2/7a,9b,1 GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400H2 HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: (3) 400HZ A 0 (LEFT BUS IN PNL) B (CENTER BUS IN PNL C (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 1 D1 -2/19a,21 b,23c 1 D1-2/13a,15b,17c 1 D1-2/2a,4b,6c D1-2/8a,10b,12 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND RED BLACK GREEN 2D1/1 a,21b,23c 20a,22b, 2C1-1/9,11 & 13,15 101-2/25a,27b,29c 1D1 -2/39b 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. CO\STUCTtON 400 I- Z PANEL 1D6-3 (1) 4"C 7#500KCMIL, JETPOWER III --� 400HZ GPU #1 180KVA 1 1/2"C PARALLELING CONTROL CABLES JETPOWER III OOHZ GPU #2 180KVA \OTES INSTALL JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT PER MANUFACTURER REQUIREMENTS. UNIT PROVIDED BY BOEING. PROVIDE CU XHHW SPIRAL WOUND CONDUCTORS AND RIGID ALUMINUM CONDUIT ROUTED OVERHEAD AND SIZED AS SHOWN. 1/2"C 3#12 4 400HZ GPU#1 STATUS TO ANNUNCIATOR PANEL 1/2"C 3#12 4 400HZ GPU#2 STATUS TO ANNUNCIATOR PANEL EVIEVVEDYFOR COMPLIANCE WITH NFPA 70 m NEC SEP 2 8 2018 of .Tukwila BUILDING DIVISION RE—USE EXISTING CONDUIT AND CONDUCTORS WHERE POSSIBLE. PROVIDE CONDUCTORS AND CONDUIT TO RECONNECT EXISTING STATUS AND COMMUNICATION WIRING TO NEW GROUND POWER UNIT. TERMINATE CONNECTIONS PER MANUFACTURER INSTRUCTIONS. PROVIDE CONDUIT AND INSTALL JTP3 PLUS PARALLELING KIT CABLES. CABLES PROVIDED WITH JTP3 PLUS GROUND POWER UNITS. INSTALL PER MANUFACTURER INSTRUCTIONS. 0 4 8 16 24 =IRS -LOGE' P SCALE: 1/8"- _A . EFER \ICE DRAWING 13-003-2E160 ;LI 76"" C:ETY OF TU;KWIL%A AUG 31 2018 P,E R M I I C:1 ('i ft A SCALE: 1/8"=1'-0" ISSUE FOR CONSTRUCTION AUGUST 10, 2018 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION 0 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 8 RELOCATE OUTLETS J#771978—LO K. DARCY 6/02/97 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C REPLACE 400 HERTZ GENERATORS RECORD DRAWING 32317 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 DRAWN T. BENNEI CHECKED S. DANG DATE SUBTITLE 400 HZ & 28V DC POWER PLAN ENGINEER T. BENNETT CHECKED S. DANG TITLE INCREASE 400HZ POWER SYSTEM CABINS ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM J08 NO. 181-085 CURRENT REVISION 35379 SYMBOL DATE 08.10.18 SHEET APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 ELECTRICAL MASTER BUILDING 13-03 COL. A—H/1-7 1E160 Dev. Center,Wa JOB NO. DWG NO. COMP NO. 2 C3J 6 INSULATED GROUND CABLE (GREEN #6 INSULATED GROUND CABLE (GREEN) Li— 0-) JETPOWER III 400HZ GPU 1 18OKVA JETPOWER III 400HZ GPU 2 180KVA —1 #4/0 CU TO BUILDING STEEL OVERHEAD #4/0 CU TO BUILDING STEEL OVERHEAD SWITCHBOARD BUS BAR LL MOUN ED 2 X6" 'CADWELD' OUND BAR AT 14" AFF WITH 2700V U LATO R. #4/0 TO GROUND GRID. -RST FLOOD DLA\ SCALE: 1/8" = 1'-0" #4/0 BARE GRD CABLE 0758 LEG GE EXOTHERMIC WELD GROUND CABLE CONNECTION TO GROUND BAR OR STEEL COLUMM. SAL \OTES: REFER TO SPECIFICATION SECTION 16450, SECONDARY GROUNDING. WHERE GROUND CONDUCTORS ARE RUN IN RIGID CONDUIT, CONDUCTORS MUST BE BONDED TO EACH END OF CONDUIT PER N.E.C. CONDUIT: ABOVEGROUND: UL 6, HOT—DIP GALVANIZED RIGID STEEL UNDERGROUND AND EMBEDDED IN CONCRETE: RIGID GALVANIZED CONDUIT WITH 40 MIL PVC JACKET CONDUIT FITTINGS: FOR RIGID CONDUIT: UL 514B, GALVANIZED FOR PVC COATED CONDUIT: RIGID GALVANIZED STEEL WITH 40 MIL PVC JACKET 6. WIRE: BARE: COPPER, STRANDED INSULATED: COPPER, STRANDED PER NEMA WC 5; TYPE THHN/THWN, 600 VOLT INSULATION CO \S R C 10\ NOTES BOND 400HZ GROUND POWER UNIT GROUND BUS TO BUILDING STEEL OVERHEAD WITH #4/0 CU BONDING JUMPER. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR GROUNDING TERMINATION LOCATION. RE—ATTACH EXISTING GROUNDING CONDUCTOR TO GROUND POWER UNIT #1 GROUND BUS. REVIEWED FOR COMPLIANCE IECT�I NFPA SEP 2 8 2018 16' City Tf kwila BUILDING DIVISION_ ISSUE FOR CONSTRUCTION AUGUST 10, 2018 CE Y OF .} UKi!VILA AUG 31 2018 PERMIT CENTER E ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A B C ISSUE FOR CONSTRUCTION REPLACE 400 HERTZ GENERATORS RECORD DRAWINGS RECONCILED TO VAULT INCREASE 400HZ POWER SYSTEM SMD TB JMK 03.14.96 32317 CASNE CEC 02.01.17 32317 CASNE SHG 06.26.17 NO RM 03.27.18 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNLI1 SUBTITLE GROUNDING CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNEII APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL A—H/1-7 Dev. Center,Wa SHEET 1E9 JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E9 SYM REVISION BY 1E2 E508 ([T, T 145 100/NF45 100/NF IN SLAB 1 D6-1/2,4,6 IN SLAB 1D6-1/8,10,12 APPROVED DATE SYM E) 0 REVISION i 1D1 J4) IN SLAB 1 D6/1,3,5 N BY 75 45 30 U 0 1D5 1D6-1/7,9,11 03> D4 MCC 1D5 1D6-1/13,15,17 X1 D7/1,3,5 1D6,-1/14,1 400 HZ PN 106-3 W 2'X2' NEMA 1 PULL BOX 106/37,39,41 JETPOWER III 400HZ GPU #2 180KVA DISCONNECT ERST FLOO PLA\ SCALE: 1/8"=1 —0" APPROVED DATE A ISSUED FOR CONSTRUCTION 03.14.96 B REPLACE 400HZ GENERATORS 32317 D. OTTEN DLO 01.16.17 C INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 • •` <A4> \ &(2)4" SPARE \ • TO SOUTH SUB 93F3 HANDHOLE TO SITE EMERG. PANEL—X IN SOUTH SUBSTATION 4"C-4#4/0 & 2G (3)4"C—SPARE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG 8' 4' 0 4' 8' 16' SCALE: 1 /8"=1'-0" 11 g DATE CHECKED T. BENNETT SUBTITLE REVIEWED F UNFPA 9E� � SEP 2 8eN2018 City of Tukwila DIVISION BUILDING Li 8- 0 iS BUILDING_.� LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND RACEWAY TYPE DESIGNATION — REFER TO SINGLE LINE DIAGRAM E4 FOR RACEWAY SCHEDULES DJ 60 NF ©45 ET; 45 480Y/277 V, 3—PHASE, 4—WIRE PANELBOARD DISCONNECT SWITCH — RATING AS SHOWN SWITCH RATING/FUSE RATING (NF=NON—FUSED) DRY TYPE TRANSFORMER — SIZE AS NOTED CEILING MOUNTED DRY TYPE TRANSFORMER — SIZE AS NOTED GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES 2" AND ABOVE AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B (CENTER BUS IN PNL) RED ORANGE C (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS r. �0 \ST'„CTIO\ \CTES PROVIDE CU CONDUCTORS, OVERHEAD CONDUIT AND SUPPORTS FROM PANEL 1D6 TO 400HZ GROUND POWER UNIT #2. RE—USE EXISTING CONDUIT AND CONDUCTORS TO RECONNECT 400HZ GROUND POWER UNIT #1. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2” 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 (M4) 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 F6 250A 1 3" 3#250MCM 250MCM #2 (I,5 100A 1 1-1/4" 3#2 . #2 #6 #6 50A 1 1" 3#8 #10 e 4 ; IA 501`' V 0 2 ;, 0 ® 250A 1 2-1/2" 3#250MCM #4 F4 225A 1 2-1/2" 3#4/0 #4/0 #2 A4 1600A 4 4" 3#600MCM 600MC,l/rr. 11499_1 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 480 VOLT MAIN POWER PLAN CiTY OF TUKWILAA: AUG 31 2018 PERMIT CENTER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98 . (425) 522-1000 wrtw �d CNG gnu JOB NA ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th 205 KIRKLAND, WA 98033 WWW.CASNE.COM NO. 181-085 CURRENT REVISION SYMBOL 35379 C DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. XA—H/1-7 DEV. CENTER, WA SHEET 1E2 JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E2 OTTEND: 5/31/2017 3:40:48 PM CO\ST,CTIO\ \ OTES PROVIDE CU CONDUCTORS, CONDUIT AND ANCILLARY HARDWARE. INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (GPU) PROVIDED BY BOEING. CONNECT TO PANEL 1D6 AND 1D6-3 AS SHOWN. PROVIDE CU XHHW SPIRAL WOUND CONDUCTORS AND RIGID ALUMINUM CONDUIT SIZED PER FEEDER SCHEDULE. RE—USE EXISTING CONDUIT WHERE POSSIBLE. REFER TO E508 AND BOEING 400HZ WIRING SPECIFICATION FOR WIRING DETAIL. DO NOT TOUCH EXISTING LINE DROP COMPENSATORS (LDCs). CONTRACTOR SHALL BE LIABLE FOR ANY DAMAGE TO LDCs. VERIFY VOLTAGES AT LOAD LOCATIONS AFTER COMPLETING INSTALLATION AND COORDINATE WITH BOEING IF ANY ADJUSTMENTS ARE REQUIRED. PROVIDE CONDUCTORS AND CONDUIT TO RECONNECT EXISTING STATUS CONTACT WIRING TO NEW GROUND POWER UNIT. TERMINATE CONTACT CONDUCTORS PER MANUFACTURER INSTRUCTIONS. PROVIDE "DUAL MOUNTED HARDWARE KIT" FOR EXISTING SWITCHBOARD 1 D6-3. PROVIDE 600A 3PH GE TYPE THJK BREAKER IN EXISTING SWITCHBOARD 1D6-3. POST BREAKER DERATING TABLE INSIDE PANEL DOOR. DERATING TABLE PROVIDED WITH SPECIFICATION SET. PROVIDE CONDUIT AND JTP3 PLUS PARALLELING KIT CABLES. CABLES PROVIDED WITH JTP3 PLUS GROUND POWER UNITS. INSTALL PER MANUFACTURER INSTRUCTIONS. 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH 55' 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH XX" 180 KVA/144 KW 200/115V, 400 HZ 3 PH, 4 W OUTPUT 1-1/2"C C PARALLELING CONTROLS 180 KVA/144 KW 200/115V, 400 HZ 3 PH, 4 W OUTPUT 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS PANEL D6-3 - MAIN 400 HZ POWER DISTRIBUTION SWITCHBOARD WITH LDC 200/115 VOLT, 3000 A, 400 HZ, 3 PH, 4 WIRE (6,000 AIC AT 400 HZ) 1 (TYPICAL ALL BREAKERS) 175400 AF 400 AF 400 AF 400 AF AF ) AT / 175 AT / 175 AT / 175 AT / 175 AT LINE DROP COMPENSATOR 6% TAP 45 KVA 45 KVA 45 KVA 45 KVA 45 KVA SPARE U8 1 (TYP) Est. 120' Est. 125' 8 PNL 1D1-2 200Y/115V 200A MBKR 400 HZ 6 PNL 2D1 200Y/115V 200A MBKR 400 HZ Est. 145' 8 6> PNL 2A4-3 200Y/115V 200A MBKR 400 HZ Est. 75' 8 6 i PNL 2D4-1 200Y/115V 200A MBKR 400 HZ r T8 400 AF 300 AT 400 AF 300 AT LINE DROP COMPENSATOR 6% TAP 400 AF 300 AT 400 AF 300 AT 75 KVA 175 KVA 175 KVA 175 KVA 175 KVA I 400 AF 300 AT SPACE FOR FUTURE BRKS. 400 AF (2 MIN) Est. 125' 8 O Est. 125' 8 Est. 125' 8 O Est. 125' UNDER FLOOR J—BOX TYP. OF 4 SEE 2E160 POWER DISTRIBUTION UNIT PDU #1 POWER DISTRIBUTION UNIT PDU #2 -I L -1 AVIONICS INTERGRATION LAB LAB #1 Est. 140'-155" FEEDERS PARALLELED IN JUNCTION BOX 1-1 200/200 200 NATO AVIONICS INTERGRATION LAB 2nd Floor Q Col. B2 REVIEWED FOR COMPLIANCE ITO I FPA7 SEP 2 8 2018 Clh► of.TukWUa I. DING DIV SI.N LEGE\D GE \E BREAKER WITH 120V SHUNT TRIP SAL \ OTES ALL CONDUITS AND FITTINGS FOR 400 HERTZ CABLING TO BE ALUMINUM AND SHALL BE ARRANGED WITH MAXIMUM PHYSICAL SEPARATION FROM COMMUNICATION RACEWAYS AND OTHER CABLES. 400HZ GEN AND DISTRIBUTION SWITCHBOARD INPUT/ OUTPUT CIRCUIT BREAKERS TO BE SPECIALLY MANUFACTURED WITH CALIBRATION FOR 400 HZ SYSTEM APPLICATION. ALL 400 HZ FEEDERS TO HAVE 90°C, TYPE XHHW-2 INSULATION UNLESS OTHERWISE NOTED. 400 HZ FEEDERS TO BE IN A SPIRAL WOUND CONFIGURATION. REFER TO DETAIL 3, SHEET E508. INSTALLED IN 400HZ DISTRIBUTION SWITCHBOARD. FRONT ACCESS. 6 > 120V SHUNT TRIP MAIN BREAKER BREAKER EQUIPTED WITH N.O. AND N.C. AUX CONTACTS. 8 > FEEDER LENGTHS SHOWN ARE APPROXIMATE. 4 >3 4> 4 4 i 3 4 3 FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG ® 250 A 1 2-1/2" 3-250 MCM #4 F4 600A 1 4" 6-500 MCM #500MCM #2/0 10)3 200 A 1 2-1/2" 6 #1/0 #1/0 #3 U8 175 A 1 2" 6 #2 #2 #4 ® 300A 2 2 1/2" 3— #4/0 #4/0 #3 W8 200 A 1 2 1/2" 3— 4/0 4/0 #3 p Y, *fttey ,Cis a i..::,i- Aura 1"111.! 1 ?bR4R ISSUE FOR CONSTRUCTION AUGUST 10, 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTUCTION SMB TB JMK 03.14.96 RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED B C D DCN 29 - REVISE PER MANUF. DESIGN NATO AWACS INTEGRATION LAB J#170097 REPLACE 400 HERTZ GENERATORS 32317 SD TB DEH JK KR JV/AW CASNE CEC 8.23.96 E INCREASE 400HZ POWER SYSTEM 35379 CASNE 08.10.18 APPROVED BY DEPT. DATE 02.01.17 \e' RECORD DRAWING 32317 CASNE SHG 06.26.17 DRAWN S. DANG DATE SUBTITLE CHECKED T. BENNEII ENGINEER S. DANG TITLE ONE LINE DIAGRAM 400 HZ POWER SYSTEM CURRENT REVISION 35379 SYMBOL E DATE 08.10.18 SHEET REPLACE 400 HERTZ GENERATORS CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI BUILDING 13-03 E4E JOB NO. 02.12.95 ELECTRICAL MASTER Dev. Center,Wa DWG NO. COMP NO. MFC -95060 13-03—E4E OTTEND: 03/07/16 10:42 / co / 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PANEL 1 D6 - MAIN DISTRI3UTION SWITCH3OAKD @ BLDG. 13-03, COL. D/6 LT ST GF 800 AF 800 AT PNL 2D5-1 150 A MAIN 3PH, 4W PNL 2C1 150 A MAI N 3PH, 4W PNL 2D5 800 A MAIN 3PH. 4W ///// PNL 2D5-2 150 A MAI N 3PH, 4W LIGHTING PNL 2A4 150 A MAI N 3PH. 4W (F76) K13 HLC 75 KVA - N 208Y/120 V J 100A K50 HLC -i-V-Y--45KVA b -1 100A EJ 100A -1100A K50 K50 K13 HLC HLC HLC A U`"J`J 45 KVA A �/�' 45 KVA �A "UJ 45 KVA _0,..-6,7;i...3_0,..-6,7;i...3�MI + 1 r 208Y/120 V 208Y/120 V 208Y/120 V 208Y/120 V PNL 2A4-1 100A M. BKR. 3PH, 4W HOUSE HOUSE HOUSE COMPUTER IG COMPUTER COMPUTER IG COMPUTER IG PNL 2D4-2 100A M. BKR. 3PH, 4W COMPUTER IG LT ST GF 800 AF 800 AT PNL 3D5-1 250 A MAI N 3PH, 4W K13 HLC - ------ 30 KVA 208Y/120 V PNL 2D6-1 100 A M. BKR. 3PH, 5W COMPUTER DATA CLOSET 226D5 PNL 3D5-2 150 A MAIN 3PH, 4W LIGHTING PNL 3D5 800 A MAIN 3PH, 4W LT ST GF 0 SPARE PNL 3C1 150 A MAI N 3PH, 4W 600 AF 500 AT LT ST GF 600 AF 500 AT SPARE LT ST GF 400 AF 250 AT LT ST GF 800 AF 800 AT MCC 1D5 800 A M.L.O. 3PH, 4W SEE SHEET E4C FOR 1 -LINE K13 HLC 75 KVA -fo rrrn 208Y/120 V LT ST GF 225 AF / 225 AT PANEL -X/19,21,23 SOUTH SUBSTATION EMERGENCY PANEL X1D7 100A --I 100A --I 100A K13 K13 K13 K13 HLC HLC HLC HLC 4N men 45 KVA -0b r 45 KVA -0N ( 45 KVA b 30 KVA 208Y/120 V 208Y/120 V 208Y/120 V 208Y/120 V SEE SHEET E5 FOR 1 -LINE PNL 3B3 100A M. BKR. 3PH, 4W HOUSE PNL 3D6 250A M. BKR. 3PH, 4W HOUSE PNL 3D3 100A M. BKR. 3PH, 4W HOUSE PNL 3E3-2 150 A M. BKR. 3PH, 5W COMPUTER IG SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION SD TB JMK 03.14.96 D INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 B ADDITIONAL CIRCUITS ADL2 LAB 17056700 ESBROOK 03.27.08 C REPLACE 400 HERTZ GENERATORS 32317 CASNE CEC 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE PNL 3B1 150 A M. BKR. 3PH, 5W COMPUTER IG DRAWN S DANG PNL 3E3-1 150 A M. BKR. 3PH, 5W COMPUTER IG PNL 3D6-1 100 A M. BKR. 3PH, 5W COMPUTER D LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE:TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 45KVA K-50 - TIERNEY AC345-8T18H11O-HLC-50-QT 30KVA K-13 - TIERNEY AC330-8718H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT I ST LT GF RACEWAY TYPE DESIGNATION INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION AUTOMATIC TRANSFER SWITCH - 480V, 4 -POLE GENERAL NOTES: MAIN CIRCUIT BREAKER WITH 120V SHUNT TRIP. FEEDER LENGTHS SHOWN ARE APPROXIMATE. ACTUAL FEEDER LENGTHS SHALL BE RECORDED AND UPDATED POST CONSTRUCTION FOR SHORT CIRCUIT AND ARC FLASH CALCULATIONS. REFERENCE DRAWINGS: 13 -YD -E505 C�\STUCTIO\ \OTES INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (GPU) PROVIDED BY BOEING. CONNECT TO PANEL 1D6 AS SHOWN. RE -CONNECT EXISTING CONDUIT AND CONDUCTORS. RACEWAY SCHEDUL REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 8 2010 City of Tukwila BUILDING DIVISION TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 ® 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #4/0 F6 250A 1 3" 3#250MCM 250MCM #2 100A 1 1-1/4" 3#2 #2 #6 #6 M5 Q3 150A 1 2" 3#1/0 #4 ® 250A 1 2-1/2" 3#250MCM #4 (-FLI-). 225A 1 2-1/2" 3#4/0 #4/0 #2 CLOSET324D5 DATA Ell8 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 075 8 RECEIVED C ° OF TUKWILA AUG 31 2018 L.:.P.'111 CENTER CASNE ENGINEERING, INC. (425) s»—inrn WWW Cd<NF COAI JOB NA ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 98 . ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, 205 KIRKLAND, WA 98033 522 1000 WWW.CASNE.COM NO. 181-085 DATE CHECKED T BENNETT SUBTITLE ONE LINE DIAGRAM — 60 HZ POWER CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S DANG CHECKED T BENNETT APPROVED J KOKOCZKA APPROVED K RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHEET IE4B JOB NO. COMP NO. DWG NO. 13-003-1E4B LAST SAVED: Au STEVEN GARRET( 3-03 INCREASE 400HZ POWER SYSTEM\_DRAWINGS\13-003-E4A \DESKTOP\181-085 C:\USERS\STEVEN.GAR J4 Q 150 AF 150 AT \ 1600 AF 1600 AT FROM SOUTH SUBSTATION FEEDER 93F3 0 1600A BREAKER LT ST GF \800 AF ) 800 AT ///// /1/ PNL 1D1 i50A MAIN 3PH. 4W PNL 1D6 -2 150A MAIN 3PH, 4W PNL 1D6- 800 A MAIN 3PH, 4W PANEL 1 D6 -- MAIN DISTRIBUTION SWITCHBOARD d BLDG. 13-03, COL. D/6 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PNL 1D5 150 A MAIN 3PH, 4W LIGHTING H LC 75 KVA. 208Y/120 V K13 PNL 1D1 - 100A M. BKR. 3PH, 4W HOUSE HOUSE PNL 105 100A M. BKR. 3PH, 4W HOUSE -I 100A HLC 0 45 KVA 208Y/120 V K13 p 100A HLC A 45 KVA H LC ' n 30 KVA 208Y/120 V 208Y/120 V COMPUTER IG COMPUTER IG K13 80A FREIGHT ELEVATOR CONTROLLER 40 HP PNL 1D5-2 100 A M. BKR. 3PH, 5W COMPUTER DATA CLOSET 129D5 100 AF 100 AT J 100A CONDENSOR 1C7A 30KW COMP. (3) 1 E P FAN 400Af 400AT CONDENSOR 1C7B 30KW COMP. (3) 1 HP FAN REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ISSUE FOR CONSTRUCTION SMD TB JMK 03,14.96 RECONCILED TO VAULT NO RM 03.27.18 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 400A 400A EIJPrO DRAWN S. DANG DATE REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC SEP 2 8 2016 City of .Tukwila BUILDING DIVISION sa B LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE: TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 30KVA K-13 - TIERNEY AC330-8T18H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT RACEWAY TYPE DESIGNATION 100A NON -FUSE DISCONNECT SWITCH. RATING AS NOTED. T ST LT GF INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION GENERAL NOTES: illi ► REFER TO DETAIL SHEET E521 FOR SHUNT TRIP FEEDER LENGTHS SHOWN ARE APPROXIMATE. ACTUAL FEEDER LENGTHS SHALL BE RECORDED AND UPDATED POST CONSTRUCTION FOR SHORT CIRCUIT AND ARC FLASH CALCULATIONS. REFERENCE DRAWINGS: 13 -YD -E4 CO\S I RUCTIO \OTES PROVIDE 250A BREAKER PLUG TO REDUCE BREAKER TRIP SETTING. MATCH EXISTING PLUG TYPE. INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (CPU) PROVIDED BY BOEING, CONNECT TO PANEL 1D6 AS SHOWN. PROVIDE CU CONDUCTORS, OVERHEAD CONDUIT AND SUPPORTS PER FEEDER SCHEDULE. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 (6-6) 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1 /4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 A4 1600A 4 41, 3#600MCM 600MCM #4/0 100A 1 1-1/4" 3#2 #2 #6 #6 5 Q3 150A 1 21, 3#1/0 #4 F6 250A 1 3" 3#250MCM 250MCM #2 0 50A 1 1" 3#8 #10 100A 1 1-1/2" 3#2 #6 0.. I• • II! 11 .1 �'1 1.. •.. C..F I ... ^•��.. 1.Y 4..,. Or I LIK '\ 1L ' (i) 250A 1 2-1/2" 3#250MCM min 1 t 9n4R #4 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 E ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB N0. 181-085 CASNE ENGINEERING, INC. CHECKED T.BENNLI 1 ENGINEER SUBTITLE ONE LINE DIAGRAM 60 HZ POWER SYSTEM CURRENT REVISION SYMBOL DATE 35379 13 08.10.18 CHECKED T.BENNETT APPROVED J.KOKOCZKA APPROVED K.RAMBALDINI TITLE 02.12.96 ELECTRICAL MASTER BUILDING 13-003 SHEET IE4A SEQUENCE NO. DWG NO. Dev. Center,Wa -03-1E4A 0 4 (A 1D1-2/38,40,42 JB UP TO 2C1-1/9,11,1 1 06-3/ 14a,16b,18b 6# 1 /0+ 1 /OG(SPIR L) 1 D1 -2/19a,21 b,23c 1D1-2/13a,15b,17c 1 D1-2/2a,4b,6c 1 D 1-2/8a,10b,12 20a,22b, 2C1-1/9,11 & 13,15 1D1-2/25a,27b,29c 1D1 -2/39b 13,15 400 HZ PANEL 1 D6-3 (1) 4"C 7#500KCMIL, #2/OGND JETPOWER I 400HZ GPU 180KVA 1/2"C 3#12 400HZ GPU#1 STATUS TO ANNUNCIATOR PANEL 1/2"C 3#12 SPARE TO ANNUNCIATOR PANEL it 8 16 24 ivy. SCALE: 1/8"=1'-0" 1 e ocis0 EFER= NCE DRAWINGS ► 13-003-2E160 LEGEND: REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND HZ SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA 400 =' 20 20 200Y/115 4 5 HUBBELL 3520 400 I3D 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 400 OD 60 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 400 IV 15 15 115 2 3 HUBBELL 7487 DC FO 20 20 28 2 3 HUBBELL 6810 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 +1 28 VDC PANEL. 400 HZ PANEL. GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400HZ HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 400HZ A 0 (LEFT BUS IN PNL) B 0CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN RED BLACK GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. D v 0 0\ =S PULL BACK EXISTING CONDUCTORS AND CONDUIT FROM PANEL 106-3 FOR GROUND POWER SYSTEM #1. RETAIN CONDUCTORS AND CONDUIT FOR RE—USE AND RE—CONNECTION THROUGH NEW MAIN CIRCUIT BREAKER IN PANEL 106-3. REVIEWED FOR COMPLIANCE ITH NFPA 7 SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVED Cm, a e, SDP TUKWILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWWCASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION 0 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 B RELOCATE OUTLETS C REPLACE 400 HERTZ GENERATORS J#771978—LO 32317 K. DARCY 6/02/97 RECORD DRAWING 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 — RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN T. BENNLII DATE CHECKED S. DANG SUBTITLE 400 HZ & 28V DC POWER PLAN CURRENT REVISION 35379 SYMBOL D DATE 08.10.18 ENGINEER T. BENNETT CHECKED S. DANG APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE 02.12.96 ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. A—H/1-7 Dev. Center,Wa SHEET IEI6OR JOB NO. MFC -95060 COMP NO. DWG NO. 13-003-1E160R 45 (,T, [T J45 00/NF 100/NF IN SLAB 1D6-1/2,4,6 IN SLAB 1D6-1/8,10,12 4 IN SLAB 1 D6/1,3,5 0 1D5 f� r J4> 1D6-1/7,9,11 03) 1 MCC 1D5 �1D6-1/13,15,17 X1 D7/1,3,5 1D6,-1/14,16,18 1 1D6-3 1D6/19,21,23 1D6/20,22 2 400- 1E2 E535 CONVERTOR 400A DISCONNECT &(2)4" SPARE \\ TO SOUTH SUB 93F3 HANDHOLE TO SITE EMERG. PANEL—X IN SOUTH SUBSTATION 4"C -4#4/O & 2G (3)4"C—SPARE -0) 16' SCALE: 8"= REVIEWED'. COMPLI O �� IFPA SEP 28 2010 Dtty a UKWlla BUILDING MI ON� LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND RACEWAY TYPE DESIGNATION — REFER TO SINGLE LINE DIAGRAM E4 FOR RACEWAY SCHEDULES Vii1/A 480Y/277 V, 3—PHASE, 4—WIRE PANELBOARD DISCONNECT SWITCH — RATING AS SHOWN SWITCH RATING/FUSE RATING (NF=NON—FUSED) El 45 DRY TYPE TRANSFORMER — SIZE AS NOTED 60 NF `Tl 45 CEILING MOUNTED DRY TYPE TRANSFORMER — SIZE AS NOTED GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES 2" AND ABOVE AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B (CENTER BUS IN PNL) RED ORANGE C (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS d'O 1 II S DEN 0 LITI 0 \ OT REMOVE cs REMOVE 400A DISCONNECT SWITCH. REMOVE ABANDONED RECEPTACLE HOUSING. REMOVE CONDUIT AND CONDUCTORS FOR 400A SWITCH AND RECEPTACLE HOUSING, BACK TO SOURCE PANEL 106. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 0 80A 1 1-1/2" 3#4 #6 (C16) 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 F6 250A 1 3" 3#250MCM 250MCM #2 (1\-t15 100A 1 1-1/4" 3#2 #2 #6 #6 50A 1 1" 3#8 #10 E4 600A 2 3,x 3#350MCM #2/0 #1/0 ® 500A 2 2-1/2" 3#250MCM Q3 150A 1 2" 3#1/0 #4 F4 225A 1 2-1/2" 3#4/0 #4/0 #2 (A4) 1600A 4 4,x 3#600MCM 60C 1 Frll rp� e oN 1n A � V '�0 SLI S-0' ISSUE FOR CONSTRUCTION AUGUST 10, 2018 AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM JOB NO. 181-085 REVISION BY APPROVED DATE Y REVISION BY APPROVED DATE ISSUED FOR CONSTRUCTION 03.14.96 REPLACE 400HZ GENERATORS 32317 D. OTTEN DLO 01.16.17 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN S. DANG CHECKED T. BENNE( I DATE SUBTITLE 480 VOLT MAIN POWER PLAN CURRENT REVISION 35379 SYMBOL c DATE 08.10.18 ENGINEET2 S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. XA—H/1-7 DEV. CENTER, WA SHEET IE2R JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E2R r 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH 55' 250AT 400 HZ GROUND POWER SYSTEM NO. 1 180 KVA/144 KW 200/115V, 400 HZ 3 PH, W OUTPUT o 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS (TYPICAL ALL BREAKERS) 5 } LINE DROP COMPENSATOR 6% TAP // // /// // / / // 4/ /,/ // 400 AF 400 AF 411 AF / AF 75 AT / 175 AT / 175 AT / 175 AF � AT / 175� AT 45 . KVA 45 KVA 45 KVA 45 KVA 45 KVA SPARE U8 11> (TYP) Est. 120' Est. 125' 8 PNL 1D1-2 200Y/115V 200A MBKR 400 HZ PNL 2D1 200Y/115V 200A MBKR 400 HZ Est. 145' 8 6 j PNL 2A4-3 200Y/115v 200A MBKR 400 HZ Est. 75' 8 PNL 2D4-1 200Y/115V 200A MBKR 400 HZ r T8 PANEL 1D6-3 - MAIN 400 HZ POWER DISTRIBUTION SWITCHBOARD WITH LDC 400 AF 300 AT 4 400 AF 300 AT 5 LINE DROP COMPENSATOR 6% TAP 200/115 VOLT, 3000 A, 400 HZ, 3 PH, 4 WIRE (6,000 AIC AT 400 HZ) 4 400 AF 300 AT 4 400 AF 300 AT 1 i 400 AF 300 AT 75 KVA 75 KVA 75 KVA 75 KVA 75 KVA SPACE FOR FUTURE BRKS. 400 AF (2 MIN) Est. 125' 8 Est. 125' CJ Est. 125' 8 O Est. 125' UNDER FLOOR J—BOX TYP. OF 4 SEE 2E160 POWER DISTRIBUTION UNIT PDU #1 POWER DISTRIBUTION UNIT PDU #2 L J AVIONICS INTERGRATION LAB LAB #1 • W8 0 Est. 140'-155" FEEDERS PARALLELED IN JUNCTION BOX 200/200 200 NATO AVIONICS INTERGRATION LAB 2nd Floor © Col. B2 200/200 200 4 4> 4 > 3 ELI8-07$ M LEGE\D G BREAKER WITH 120V SHUNT TRIP \PAL \OTES 6i ALL CONDUITS AND FITTINGS FOR 400 HERTZ CABLING TO BE ALUMINUM AND SHALL BE ARRANGED WITH MAXIMUM PHYSICAL SEPARATION FROM COMMUNICATION RACEWAYS AND OTHER CABLES. 400HZ GEN AND DISTRIBUTION SWITCHBOARD INPUT/ OUTPUT CIRCUIT BREAKERS TO BE SPECIALLY MANUFACTURED WITH CALIBRATION FOR 400 HZ SYSTEM APPLICATION. ALL 400 HZ FEEDERS TO HAVE 90°C, TYPE XHHW-2 INSULATION UNLESS OTHERWISE NOTED. 400 HZ FEEDERS TO BE IN A SPIRAL WOUND CONFIGURATION. REFER TO DETAIL 3, SHEET E508. INSTALLED IN 400HZ DISTRIBUTION SWITCHBOARD. FRONT ACCESS. 120V SHUNT TRIP MAIN BREAKER BREAKER EQUIPTED WITH N.O. AND N.C. AUX CONTACTS. 8 > FEEDER LENGTHS SHOWN ARE APPROXIMATE. -VOLITIO\ \OTES PULL BACK EXISTING CONDUCTORS AND CONDUIT FROM PANEL 1D6-3 FOR GROUND POWER SYSTEM #1. RETAIN CONDUCTORS AND CONDUIT FOR RE—USE AND RE—CONNECTION THROUGH NEW MAIN CIRCUIT BREAKER IN PANEL 1D6-3. REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC SEP 2 8 2018 City of •Tukwila BUIL h IR (VISION FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG ® 250 A 1 2-1/2" 3-250 MCM #4 F4 600A 1 4" 6-500 MCM #500MCM #2/0 T8 200 A 1 2-1/2" 6 #1/0 #1/0 #3 c:1-8) 175 A 1 2" 6 #2 #2 #4 ® 300A 2 2 1/2" 3— #4/0 #4/0 #3 W8 200 A 1 2 1/2" 3— 4/0 4/0 aEG NE: „ i C TY OF TUKWILA AUG 31 2018 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 PERMIT CENTER ER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA (425) 522-1000 wwwrn cuF rnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 9803.3 WWW. CASNE. COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED A B C ISSUED FOR CONSTUCTION DCN 29 - REVISE PER MANUF. DESIGN NATO AWACS INTEGRATION LAB SMB TB JMK 03.14.96 RECONCILED TO VAULT SD TB JK KR 8.23.96 E INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG DATE 03.27.18 08.10.18 J#170097 DEH JV/AW 7.8.98 D REPLACE 400 HERTZ GENERATORS 32317 RECORD DRAWING 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 ?3, ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNETT SUBTITLE ONE LINE DIAGRAM 400 HZ POWER SYSTEM CURRENT REVISION SYMBOL 35379 DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.95 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 Dev. Center,Wa SHEET E4ER JOB NO. MFC -95060 COMP NO. DWG NO. 13-03—E4ER 0 3 N 0) 0 w U) CD 3-003-E4AR - S 3-03 INCREASE 400HZ POWER SYSTEM\_DRAWINGS\ C:\USERS\STEVEN.GARRETT\DESKTOP\181-085 BOE LT ST GF 150 AF 150 AT PNL 1D1 150A MAIN 3PH, 4W LT ST GF \ 1600 AF / 1600 AT FROM SOUTH SUBSTATION FEEDER 93F3 1600A BREAKER LT ST GF 800 AF 800 AT PNL 1D6-1 800 A MAIN 3PH. 4W PANEL 1D6 - MAIN DISTRIBUTION SWITCHBOARD @ BLDG. 13-03, COL. D/6 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PNL 1D6-2 150A MAIN 3PH, 4W PNL 1D5 150 A MAIN 3PH, 4W LIGHTING HLC 75 KVA �'lm 208Y/120 V K13 HOUSE HOUSE HOUSE • • -I 100A -I 100A HLC HLC HLC . ri 45 KVA -0.. r -,- 45 KVA LUJJ 4IP n -✓Y` y) 30 KVA 208Y/120 V 208Y/120 V K13 COMPUTER IG COMPUTER IG 208Y/120 V K13 PNL 1D5-2 100 A M. BKR. 3PH, 5W COMPUTER 80A FREIGHT ELEVATOR CONTROLLER 40 HP DATA CLOSET 129D5 LT ST GF l 100 AF / 100 AT 0 100A CONDENSOR 1 C7A 30KW COMP. (3) 1 HP FAN LT ST GF 100 AF 100 AT ---I J 100A CONDENSOR 1C7B 30KW COMP. (3) 1 HP FAN T LT GF 400AF 400AT RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 4714) 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 A4 1600A 4 4" 3#600MCM 600MCM #4/0 100A 1 1-1/4" 3#2 #2 #6 #6 M Q3 150A 1 2" 3#1/0 #4 F6 250A 1 3" 3#250MCM 250MCM #2 W3 50A 1 1" 3#8 #10 0 100A 1 1-1/2" 3#2 #6 T4 400A 1 4" 3 #500MCM LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE: TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 30KVA K-13 - TIERNEY AC330-8T18H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT RACEWAY TYPE DESIGNATION -1100A NON -FUSE DISCONNECT SWITCH. RATING AS NOTED. ST LT GF INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION GENERAL NOTES: REFER TO DETAIL 1, SHEET E521 FOR SHUNT TRIP DIAGRAM. REFERENCE DRAWINGS: 13 -YD -E4 REMOVAL NOTES: REMOVE ABANDONED CONDUCTORS TO 400A DISCONNECT ON SOUTHEAST END OF 13-003. REMOVE 400A TRIP PLUG. PREPARE BREAKER FOR RE -USE WITH NEW 400HZ GPU. REMOVE 400A DISCONNECT ALONG WITH ABANDONED RECEPTACLE ENCLOSURE. EL1 8-07 5 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED .FOR WITHCOMPLIANCE NEPA7O - NEC SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVE:0 CITY OF TUKWILA AUG 31 2018 PERMIT CENTER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGYCONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 980, (425) 522-1000 WIVW!`d CNF SNA JOB NA ELECTRICAL AND CONSULTANTS NE 38th 205 KIRKLAND, WA 98033 WWW. CASNE COM NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION SMD TB JMK 03.14.96 RECONCILED TO VAULT NO RM 03.27.18 B INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN S. DANG DATE APPROVED BY DEPT. DATE CHECKED T.BENNETT ENGINEER SUBTITLE ONE LINE DIAGRAM 60 HZ POWER SYSTEM CURRENT REVISION SYMBOL D DATE 35379 B 08.10.18 CHECKED T.BENNETT APPROVED J.KOKOCZKA APPROVED K.RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER BUILDING 13-003 Dev. Center,Wa SHEET 1 E4AR SEQUENCE NO. DWG NO. 13-03-1E4AR G \.RAL \OT is A. WORK INCLUDED: FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS FOR COMPLETION OF ALL ELECTRICAL SYSTEMS AND RELATED WORK AS INDICATED ON THE DRAWINGS. THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING SYSTEMS: 480Y/277V POWER, 208Y/120V POWER, 200/115V 400HZ, LIGHTING, GROUNDING, FIRE ALARM, DATA AND OTHER WORK AS SHOWN ON THE DRAWINGS. B. CODES AND ORDINANCES: ALL WORK SHALL COMPLY WITH LOCAL CODES AND ORDINANCES INCLUDING THE NATIONAL ELECTRICAL CODE (NEC). C. DEMOLITION: 1. UNLESS OTHERWISE INDICATED, THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL MATERIAL, EQUIPMENT, WIRING DEVICES, LIGHTING FIXTURES, CABLES, AND WIRING, INCLUDING THOSE ITEMS ASSOCIATED WITH THE TELEPHONE, DATA, PAGING AND FIRE ALARM SYSTEMS. 2. ALL UNUSED CONDUIT AND WIRING SHALL BE COMPLETELY STRIPPED AND REMOVED BACK TO THE SOURCE OR CLOSEST ACTIVE JUNCTION BOX, SCHEDULED TO REMAIN, EXCEPT WHEN LOCATED IN AN EXISTING FLOOR SLAB NOT SCHEDULED FOR DEMOLITION. UNUSED CONDUITS IN FLOOR SLAB SHALL BE CUT OFF AND PLUGGED FLUSH WITH SLAB SURFACE UNLESS OTHERWISE NOTED. 3. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BOEING REPRESENTATIVE FOR DIRECTIONS ON THE DISPOSAL, SALVAGE, RELOCATION ETC., OF ALL REMOVED ITEMS LISTED IN NOTE 1, ABOVE. 4. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE -ENERGIZING ANY POWER SERVICE REQUIRED FOR THIS DEMOLITION WORK TO ENSURE SAFE WORKING CONDITIONS. 5. THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND SCHEDULE WITH THE BOEING REPRESENTATIVE ANY POWER, TELEPHONE, DATA, CMCS, PLANT PAGING, FIRE ALARM AND ADT CONTROL SHUT DOWNS REQUIRED BY THIS DEMOLITION WORK AND ALSO ENSURE THAT ADEQUATE TEMPORARY AND/OR REROUTING OF SERVICES ARE APPROVED TO AREAS NOT PART OF THIS DEMOLITION WORK, BUT WHICH ARE ADJACENT TO THE AREA(S) OF WORK WHICH WOULD BE AFFECTED BY A SHUT DOWN. THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE BOEING STANDARD LOCKOUT/TAGOUT PROCEDURES THROUGHOUT ANY REQUIRED SHUT DOWN, DEMOLITION AND/OR TEMPORARY RECONNECTION PROCESS. 6. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BOEING REPRESENTATIVE THE MAINTENANCE AND REROUTING OF ALL EXISTING POWER, LIGHTING, TELE/DATA, FIRE ALARM, ADT AND PLANT PAGING SYSTEMS CIRCUITS THAT PASS THROUGH THE DEMOLITION AREA BUT ARE NOT INDICATED FOR REMOVAL, AS FIELD REQUIRED. 7. THE ELECTRICAL CONTRACTOR SHALL OBTAIN FROM AND COORDINATE WITH THE BOEING REPRESENTATIVE THE PROVISIONS AND REQUIREMENTS OF TEMPORARY POWER SERVICE FOR THE DEMOLITION WORK. 8. REMOVAL AND DISPOSAL OF ALL IDENTIFIED HAZARDOUS MATERIALS SHALL BE PERFORMED UNDER THE REQUIREMENTS OF BOEING SHEA, OSHA, EPA AND ANY OTHER AUTHORITY HAVING JURISDICTION IN APPLICABLE STATE, CITY AND LOCAL CODES D. RECORD DRAWINGS: MAINTAIN "AS -BUILT DRAWINGS ON SITE, UP TO DATE AT ALL TIMES. THESE DRAWINGS SHALL CLEARLY INDICATE, IN RED PENCIL ON COPIES OF CONTRACT DRAWINGS, THE LOCATIONS OF ALL CONCEALED AND UNDERGROUND CONDUIT, AND ALL DEVIATIONS TO THE DRAWINGS. E. PANEL SCHEDULES: MAINTAIN PANEL SCHEDULES WITH ACCURATE CIRCUIT BREAKER, WIRE, AND LOAD INFORMATION ON ALL ELECTRICAL PANELS INSTALLED OR REVISED UNDER THIS CONTRACT. F. MATERIALS AND EQUIPMENT: EXCEPT AS OTHERWISE INDICATED, ALL MATERIALS AND EQUIPMENT SHALL BE NEW, FREE OF DEFECTS, AND SHALL BE UL APPROVED AND LABELED. 1. RIGID METAL CONDUIT: HOT -DIP GALVANIZED, THREADED; FITTINGS AND CONDUIT BODIES TO BE THREADED TYPE, GALVANIZED, MATERIAL TO MATCH CONDUIT. 2. RIGID ALUMINUM CONDUIT: NON-MAGNETIC ALUMINUM ALLOY, THREADED; FITTINGS AND CONDUIT BODIES TO BE THREADED TYPE, MATERIAL TO MATCH CONDUIT. 3. ELECTRICAL METALLIC TUBING (EMT): STEEL TUBING, HOT -DIP GALVANIZED; FITTINGS TO BE GALVANIZED STEEL, RAIN TIGHT, INSULATED THROAT, COMPRESSION TYPE. 4. FLEXIBLE METAL CONDUIT: LIQUIDTIGHT WITH COPPER BONDING TAPE AND PVC WEATHERPROOF JACKET. 5. POLY -VINYL CHLORIDE (PVC) CONDUIT: SCHEDULE 40 OR THICKER, UL LISTED FOR DIRECT BURIAL USE. 6. OUTLET BOXES: GALVANIZED STEEL, 4" SQUARE; BOXES LARGER THAN 12 INCHES IN ANY DIMENSION TO BE HINGED ENCLOSURE, NEMA 12 OR AS OTHERWISE NOTED. 7. BUILDING WIRE: INTERIOR FEEDERS AND BRANCH CIRCUITS TO BE COPPER, STRANDED CONDUCTOR, 600V INSULATION, 90 DEGREE TYPE THHN/THWN; EXTERIOR FEEDERS AND BRANCH CIRCUITS TO BE COPPER, STRANDED CONDUCTOR, 600V INSULATION, TYPE XHHW. 8. WIRING DEVICES: SPECIFICATION GRADE AND UL LISTED, DEVICE PLATES AND DEVICE COLOR TO MATCH EXISTING IN IMMEDIATE AREA OF NEW WORK. IN GENERAL, FACTORY AREAS WILL HAVE BROWN COLORED DEVICES AND GALVANIZED STEEL DEVICE PLATES; OFFICE AREAS WILL HAVE DEVICES AND DECORATIVE DEVICE PLATES AS SPECIFIED BY THE ARCHITECT. 9. CIRCUIT BREAKERS IN EXISTING PANELBOARDS: THE SAME MANUFACTURER AND FRAME TYPE AS THOSE REQUIRED FOR THE EXISTING PANELBOARDS. RATINGS AND FRAME TYPES SHALL BE AS INDICATED ON DRAWING OR IN PANEL SCHEDULES. 10. CONDUIT AND EQUIPMENT SUPPORTS: CONDUIT CLAMPS, STRAPS, AND SUPPORTS TO BE GALVANIZED STEEL; SUPPORT CHANNEL TO BE ELECTRO -GALVANIZED, 12 GAUGE, 1-5/8"X1-5/8" MINIMUM SIZE. SUPPORT SYSTEMS SHALL BE ADEQUATE FOR WEIGHT OF EQUIPMENT AND CONDUIT, INCLUDING WIRING, WHICH THEY CARRY; AND SHALL CONFORM TO SEISMIC REQUIREMENTS OF INTERNATIONAL BUILDING CODE (IBC) 2015. 11. CIRCUIT IDENTIFICATION: NAMEPLATES TO BE ENGRAVED METAL OR PHENOLIC WITH 1/" WHITE LETTERS ON BLACK BACKGROUND; LABELS TO BE EMBOSSED ADHESIVE TAPE, 3/8" WHITE LETTERS ON BLACK BACKGROUND; WIRE AND CABLE MARKERS TO BE CLOTH MARKERS, SPLIT SLEEVE OR TUBING TYPE. G. CONDUITS: 1. USE 3/4" EMT UNLESS OTHER NOTED OR AS SHOWN ON THE DRAWINGS. 2. USE RIGID GALVANIZED STEEL FOR ALL EXPOSED CONDUIT RUNS ABOVE GROUND, IN CHASES, SUBJECT TO PHYSICAL DAMAGE OR SUBJECT TO MOISTURE. 3. USE RIGID ALUMINUM FOR ALL 400HZ CONDUIT RUNS. 4. USE PVC CONDUIT LISTED FOR DIRECT BURIAL UNDERGROUND, IN CONCRETE OR IN DUCT BANKS. ALL RISERS SHALL USE PVC COATED STEEL ELBOWS COUPLED TO PVC CONDUIT WITH LISTED ADAPTERS. 5. HEADROOM SHALL BE REQUIRED TO BE 7'0" MINIMUM UNLESS OTHERWISE SHOWN ON DRAWINGS OR APPROVED BY OWNER. 6. ROUTE EXPOSED CONDUIT PARALLEL AND PERPENDICULAR TO WALLS AND ADJACENT PIPING. 7. MAINTAIN MINIMUM 6" CLEARANCE BETWEEN CONDUIT AND PIPING. MAINTAIN MINIMUM 12" CLEARANCE BETWEEN CONDUIT AND HEAT SOURCES SUCH AS FLUES, STEAM PIPES, AND HEATING APPLIANCES. 8. DO NOT FASTEN CONDUIT WITH WIRE OR PERFORATED PIPE STRAPS. REMOVE ALL WIRE USED FOR TEMPORARY CONDUIT SUPPORT DURING CONSTRUCTION, BEFORE CONDUCTORS ARE PULLED. 9. CONDUIT TERMINATIONS AT SWITCHBOARDS, PULL BOXES, ETC., SHALL BE RIGIDLY SECURED USING LOCKNUTS AND METALLIC GROUNDING INSULATING BUSHINGS WHERE REQUIRED OR AS INDICATED ON DRAWINGS. 10. USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS, ON APPROVAL OF ENGINEER ONLY. 11. WHERE CONDUITS ENTER/EXIT FLOOR, PROVIDE THREADED COUPLING WITH UPPER END FLUSH WITH FINISHED FLOOR. INSTALL THREADED PLUGS IN UNUSED CONDUITS. 12. SEAL RACEWAY PENETRATION WHERE RACEWAY PASSES THROUGH EXTERIOR WALL, FLOOR OR RATED FIREWALL WITH MATERIAL COMPATIBLE WITH THE BUILDING MATERIAL THROUGH WHICH THE RACEWAY PASSES. ALL SEALING COMPOUNDS MUST BE UL LISTED FOR THE APPLICATION. H. COORDINATION OF BOX LOCATIONS: 1. PROVIDE ELECTRICAL BOXES AS SHOWN ON THE DRAWINGS, AND AS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS AND CODE COMPLIANCE. 2. SUPPORT BOXES INDEPENDENT OF CONDUIT. 3. ELECTRICAL BOX LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE UNLESS DIMENSIONED. 4. LOCATE AND INSTALL BOXES TO ALLOW ACCESS. WHERE INSTALLATION IS INACCESSIBLE, COORDINATE LOCATIONS AND SIZES OF REQUIRED ACCESS DOORS. 5. LOCATE AND INSTALL TO MAINTAIN HEADROOM AND TO PRESENT A NEAT APPEARANCE. HEADROOM SHALL BE REQUIRED TO BE 7'-O" MINIMUM UNLESS OTHERWISE SHOWN ON DRAWINGS OR APPROVED BY OWNER. REVISION BY APPROVED DATE SYM REVISION G \HA OT is CO\TI\ D I. SUPPORTING DEVICES: 1. FASTEN HANGER RODS, CONDUIT CLAMPS, AND OUTLET AND JUNCTION BOXES TO BUILDING STRUCTURE USING BEAM CLAMPS. 2. USE SELF -DRILLING ANCHORS OR EXPANSION ANCHORS ON CONCRETE SURFACES; SHEET METAL SCREWS IN SHEET METAL STUDS. 3. DO NOT FASTEN SUPPORTS TO PIPING, DUCTWORK, MECHANICAL EQUIPMENT OR CONDUIT. 4. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR STEEL CHANNEL, RIGIDLY WELDED OR BOLTED TO PRESENT A NEAT APPEARANCE. USE HEXAGON HEAD BOLTS WITH SPRING LOCK WASHERS UNDER ALL NUTS. COLD GALVANIZE ENDS OF CUT CHANNEL IN EXTERIOR AND/OR DAMP LOCATIONS. 5. IN WET LOCATIONS, INSTALL FREE STANDING ELECTRICAL ENCLOSURES ON HOUSEKEEPING PADS, 3" MINIMUM HIGH. 6. INSTALL SURFACE MOUNTED CABINETS, ENCLOSURES, AND PANELS WITH A MINIMUM OF FOUR ANCHORS. PROVIDE STEEL CHANNEL SUPPORTS AND PROVIDE A MINIMUM OF 1" GAP BETWEEN WALL AND EQUIPMENT. J. DEVICE MOUNTING HEIGHT AND ORIENTATION: 1. FACTORY AREAS: MOUNT DEVICES AT 48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. IF IMMEDIATE AREA HAS DEVICES MOUNTED BELOW 48", CONTACT OWNER FOR RESOLUTION OF MOUNTING HEIGHT. 2. SWITCHES SHALL BE MOUNTED WITH OFF POSITION DOWN. K. GENERAL WIRING METHODS: 1. USE WIRE NO SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS, AND NO SMALLER THAN 14 AWG FOR CONTROL WIRING, UNLESS OTHERWISE NOTED ON THE DRAWINGS. 2. FOR 400HZ SYSTEMS USE WIRE NO SMALLER THAN #10 AWG. WIND CONDUCTORS IN A SPIRAL CONFIGURATION TO EQUALIZE PHASE IMPEDANCES AND MINIMIZE VOLTAGE DROP. 3. SPLICE ONLY IN JUNCTION OR OUTLET BOXES. NO SPLICING SHALL BE PERMITTED IN PANELBOARD ENCLOSURES WITHOUT SPECIFIC APPROVAL FROM OWNER. 4. FEEDERS SHALL NOT BE SPLICED WITHOUT SPECIFIC APPROVAL FROM OWNER. 5. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. L. WIRING CONNECTIONS AND TERMINATIONS: 1. SPLICE ONLY IN ACCESSIBLE JUNCTION BOXES. 2. THOROUGHLY CLEAN WIRES BEFORE INSTALLING LUGS AND CONNECTORS. 3. MAKE SPLICES, TAPS AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITHOUT PERCEPTIBLE TEMPERATURE RISE. 4. TERMINATE DEAD -ENDED CONDUCTORS WITH ELECTRICAL TAPE AND MAKE SAFE. A. GROUNDING: 1. UNDERGROUND GROUND GRID CONDUCTORS SHALL BE #4/0 BARE COPPER STRANDED UNLESS OTHERWISE NOTED. 2. FENCE POST AND FENCE GROUNDING WIRES SHALL BE #2 BARE COPPER STRANDED UNLESS OTHERWISE NOTED. 3. ALL GROUND GRID WIRES SHALL BE BURIED A MINIMUM OF 12" BELOW FINISHED GRADE. 4. ALL CABLE TO CABLE GROUND CONNECTIONS SHALL BE EXOTHERMIC WELDED. 5. ALL CABLE TO EQUIPMENT OR GROUND BUS CONNECTIONS SHALL BE MADE WITH COMPRESSION TERMINAL LUGS. 6. ALL FENCE POSTS SHALL BE GROUNDED TO YARD GROUND GRID USING MECHANICAL CLAMPS. 7. ALL FENCE GATES SHALL BE GROUNDED WITH FLEXIBLE COPPER BRAID. M. COLOR CODING: 1. INSULATION ON CONDUCTOR SIZES #6 AWG AND SMALLER SHALL BE COLORED. CONDUCTOR SIZES #4 AWG AND LARGER MAY HAVE BLACK INSULATION WITH PLASTIC TAPE OF THE APPROPRIATE COLOR FROM THE TABLE BELOW. DESCRIPTION 120/208V 277/480V PHASE A (LEFT) BLACK BROWN PHASE B (CENTER) RED ORANGE PHASE C (RIGHT) BLUE YELLOW NEUTRAL WHITE WHITE GROUND GREEN GREEN ALTERNATIVELY FOR 400HZ SYSTEMS, USE THE APPROPRIATE COLOR FROM THE TABLE BELOW. 400HZ DESCRIPTION PHASE A (LEFT) PHASE B (CENTER) PHASE C (RIGHT) NEUTRAL GROUND 115/200V BLACK RED BLUE WHITE GREEN 330/575V BROWN ORANGE YELLOW WHITE GREEN FOR 28VDC SYSTEMS, USE THE FOLLOWING TABLE 28VDC POSITIVE (+) NEGATIVE (-) GROUND RED BLACK GREEN N. CIRCUIT IDENTIFICATION: 1. USE EMBOSSED TAPE FOR INTERIOR 120V RECEPTACLES, 120V & 277V SWITCHES, BOXES AND DEVICES, AND JUNCTION BOXES. 2. INSTALL ENGRAVED NAMEPLATES ON ALL 480V RECEPTACLES, EQUIPMENT DISCONNECTS, CONTROL PANELS, ETC., AND ALL EXTERIOR EQUIPMENT AND DEVICES, INSTALLED OR REVISED UNDER THIS CONTRACT. THIS INCLUDES THOSE NOT PHYSICALLY RELOCATED BUT RECIRCUITED. 3. SECURE NAMEPLATES TO EQUIPMENT USING SCREWS OR WIRE LOOP. ADHESIVES ARE NOT ACCEPTABLE. 4. NAMEPLATES AND LABELS SHALL INDICATED PANEL AND CIRCUIT NUMBER EQUIPMENT IS SERVED FROM. (E.G. - "206A5E/2A FOR CIRCUIT 2A FROM PANEL 206A5E) 5. PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARD GUTTERS, PULL BOXES, OUTLET AND JUNCTION BOXES, AND AT ALL LOAD CONNECTIONS. IDENTIFY WITH BRANCH CIRCUIT OR FEEDER NUMBER AS INDICATED ON DRAWINGS. FOR CONTROL WIRING, IDENTIFY WITH WIRE NUMBER INDICATED ON THE SCHEMATIC OR INTERCONNECTION DIAGRAMS. 0. EMERGENCY POWER IDENTIFICATION: 1. IDENTIFY ALL BOXES, ENCLOSURES, PANELS, ETC. WHICH CONTAIN EMERGENCY POWER CIRCUITS AND ARE INSTALLED OR WORKED IN WITH APPROPRIATE "EMERGENCY SYSTEM" LABELS AS REQUIRED BY THE WAC. 2. EMERGENCY POWER WIRING SHALL BE INDEPENDENT OF OTHER WIRING AND EQUIPMENT EXCEPT AS PERMITTED BY NEC. BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 i"Th ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE SCG SST_ D WOR< FLOW THE FOLLOWING IS A SUGGESTED ORDER OF OPERATIONS TO COMPLETE THE WORK OUTLINED IN THIS DRAWING SET. THIS LIST IS NOT COMPREHENSIVE; THE CONTRACTOR SHALL REFER TO THE ATTACHED DRAWINGS FOR FURTHER DETAIL ON WORK TO BE PERFORMED. ALL WORK SHALL BE COORDINATED WITH BOEING. 1. RE -PLACE JBT JETPOWER III GROUND POWER UNIT (GPU) #1 SUPPLIED BY BOEING. SECURE USING NEW ANCHORAGE. 2. PLACE NEW JBT JETPOWER III GROUND POWER UNIT (GPU) SUPPLIED BY BOEING. PROVIDE ANCHORAGE SIMILAR TO EXISTING JBT JETPOWER 111 UNIT. 3. BOND GROUND POWER UNITS TO BUILDING STEEL ACCORDING TO MANUFACTURER AND NEC REQUIREMENTS. 4. PROVIDE 60HZ CONDUCTORS AND CONDUIT FROM PANEL 1D6 TO GENERATORS. 5. INSTALL 600A MAIN CIRCUIT BREAKERS IN PANEL 1D6-3 (TWO TOTAL, ONE PER GPU). 6. PROVIDE 400HZ SPIRAL WOUND CONDUCTORS BETWEEN GPU#2 AND NEW DISCONNECT SWITCH. RE -PURPOSE EXISTING CONDUCTORS FOR GPU#1. 7. PROVIDE AUX STATUS CONTACT CONNECTIONS BETWEEN JETPOWER III GROUND POWER UNITS AND 400HZ ALARM PANEL. 8. TEST, COMMISSION AND TRANSFER POWER FROM EXISTING PORTABLE GPU TO PARALLELED GPU #1 AND #2 BY FINALIZING CONNECTION BETWEEN 400HZ GENERATORS AND PANEL 1D6-3 MAIN BREAKERS, 9. VERIFY VOLTAGE AND ADJUST GROUND POWER UNIT SETTINGS AS REQUIRED FOR PROPER OPERATION. DRAWN S.GARRE I I CHECKED S.GARREI I DATE 08.03.18 08.03.18 SUBTITLE ELI 8O7S9 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 NOTES, SYMBOLS AND ABBREVIATIONS REVIEWED .FOR COMPLIANCE WITH FPA 70 m NEC SEP 2 8 2018 City of.Tukwil BUILDING DIVISION RECEIVED MN OF TUKWILA AUG 31 2018 z ERMVIIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED 08.03.18 08.03.18 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM 13 -YARD SHEET E16 JOB NO. 35379 COMP NO. DWG NO. M.F.C. -003-E1 B D 30/20 M 0 0 GROUNDING GROUND CABLE CONNECTION GROUND ROD CONNECTION GROUND CABLE PIGTAIL GROUND CABLE (UNDERGROUND) POWER — GENERAL PANELBOARD, 208Y/120V, 3 PHASE PANELBOARD, 480V OR 480Y/277V, 3 PHASE PANELBOARD, 400 HZ, 200/115V, 3 PHASE PANELBOARD, 28 VDC, POSITIVE AND NEGATIVE EQUIPMENT IDENTIFICATION "X" DENOTES EQUIPMENT NUMBER "Y" DENOTES HP OR AMPS CIRCUIT BREAKER ENCLOSURE CIRCUIT BREAKER DISCONNECT SWITCH DISCONNECT SWITCH (FUSED OR UNFUSED) SWITCH RATING/FUSE RATING MAGNETIC MOTOR STARTER MAGNETIC MOTOR STARTER (COMBINATION) MANUAL MOTOR STARTER TRANSFORMER (SIZE AS SHOWN, IN KVA) JUNCTION BOX OFF/ON SELECTOR SWITCH CONTROL STATION STOP–START PUSHBUTTON CONTROL STATION 460 VOLT MOTOR (SIZE AS NOTED) 208 VOLT OR 240 V MOTOR (SIZE AS NOTED) 115 VOLT MOTOR (SIZE AS NOTED) CONTACTOR RACEWAYS EXPOSED CONDUIT RUN (TYPE AS NOTED) CONCEALED CONDUIT RUN (TYPE AS NOTED) FLEXIBLE CONDUIT RUN CONDUIT HASH MARK DESIGNATIONS PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUND CONDUCTOR ISOLATED GREEN GROUND CONDUCTOR CIRCUIT SOURCE PANEL/CIRCUIT BREAKER N0.(S) ) CONDUIT TURNS DOWN 0 CONDUIT TURNS UP CONDUIT ONLY C.O. PLAN SYMBOLS 15 1 20 Iltc 20 60 POWER RECEPTACLES SINGLE, 2–POLE, 3–WIRE, PARALLEL BLADE, NEMA 5-15 GROUNDING RECEPTACLE, 15 AMP, 120 V, HUBBELL 5262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2–POLE, 3–WIRE, PARALLEL BLADE, NEMA 5-15 GROUNDING RECEPTACLE, 15 AMP, 120 V, HUBBELL 5262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2–POLE, 3–WIRE, STRAIGHT BLADE, NEMA 5-20 GROUNDING RECEPTACLE, 20 AMP, 120 V, HUBBELL 5362 OR EQUAL PER BOEING STANDARDS (2) SINGLE, 2–POLE, 3–WIRE, EXPLOSION–PROOF (GROUND THRU EXTRA POLE & SHELL) 20 AMP, 120 V, CROUSE–HINDS CPS152-102 RED=(1) HOT, WHT=(2) NEUT., PLAIN=GROUND 480 VAC, 4–POLE, 3–WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 60 AMP, CROUSE–HINDS ARE 6425 LIGHTING REFER TO SHEET E500 FOR FIXTURE SYMBOLS AND SCHEDULE COMMUNICATIONS TELEPHONE OUTLET DUPLEX TELEPHONE OUTLET T O 480:120 800:5 AS E19-1 400 A M. BKR. 3 PH, 4 W E19-3 225 A M. BKR. 3 PH, 4 W OR SINGLE LINE TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC SHIELD) SURGE ARRESTER CIRCUIT BREAKER DRAW–OUT TYPE POTENTIAL TRANSFORMER QUANTITY & RATIO AS SHOWN CURRENT TRANSFORMER QUANTITY & RATIO AS SHOWN AMMETER w/SWITCH VOLTMETER w/SWITCH WATTHOUR METER 480V OR 480Y/277V PANELBOARD (RATINGS AS NOTED) 208V OR 208Y/120V PANELBOARD (RATINGS AS NOTED) COMBINATION STARTER CONTROLLER OR MCC CUBICLE NUMBER STARTER SIZE POWER FACTOR CORRECTION CAPACITOR MOTOR HORSEPOWER WIRING DIAGRAM SYMBOLS SINGLE LINE FUSED SWITCH M.V. DISCONNECT SWITCH L.V. DISCONNECT SWITCH INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL FEEDER TYPE DESIGNATION GENERATOR TRANSFER SWITCH Fp DISCONNECT SWITCH H L~ nr'n / \ INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL SCHEMATIC DISCONNECT SWITCH FUSE CIRCUIT BREAKER TRANSFORMER GROUND CONNECTION PILOT LIGHT * INDICATES COLOR PUSHBUIION —0 o— MOMENTARY CONTACT NORMALLY OPEN PUSHBUTTON —n 1 c}--- MOMENTARY CONTACT NORMALLY CLOSED OFF „- ON SELECTOR SWITCH MAINTAINED CONTACT -0— TWO POSITION 2 —;--2 SELECTOR SWITCH MAINTAINED CONTACT THREE POSITION SCHEMATIC SOLENOID VALVE PRESSURE SWITCH – N.C. OPENS ON RISING PRESSURE PRESSURE SWITCH – N.O. CLOSES ON RISING PRESSURE FLOAT OR LEVEL SWITCH – N.C. OPENS ON RISING LEVEL FLOAT OR LEVEL SWITCH – N.O. CLOSES ON RISING LEVEL FLOW SWITCH – N.C. OPENS ON INCREASE IN FLOW FLOW SWITCH – N.O. CLOSES ON INCREASE IN FLOW TEMPERATURE SWITCH – N.C. OPENS ON RISING TEMP TEMPERATURE SWITCH – N.O. CLOSES ON RISING TEMP o— LIMIT SWITCH – N.C. —oma a LIMIT SWITCH – N.O. --0-I I-0— „No RELAYS & COILS *=TYPE M= MOTOR STARTER CR=CONTROL RELAY C=CONTACTOR TR=TIME DELAY OR TIMING RELAY N.O. CONTACT N.C. CONTACT N.O. – ON DELAY CONTACT \LC. – ON DELAY CONTACT N.O. – OFF DELAY CONTACT N.C. – OFF DELAY CONTACT .~REVIEWED FOR C©MPLIANCE WITH I9FPA 70 - NEC • SEP 2 8 1018 BUILDING DIVISION City of .Tukwila GENERAL NOTES 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. ALL CONDUITS AND FITTINGS FOR 400HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. USE #14 AWG FOR LOW VOLTAGE CONTROL WIRING. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS AS FOLLOWS: A 0 (LEFT BUS IN PNL) B 0 (CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 208Y/120V 480Y/277V BLACK RED BLUE WHITE GREEN GREEN WITH BROWN ORANGE YELLOW GRAY GREEN YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL–WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. L ISSUE FOR CONSTRUCTION AUGUST 10, 2018 ABBREVIATIONS AF AFF AHU AL AT AWG CB CMCS CO DED EF EMT EWC FVNR GFI GND HP IMC kcMIL LV M.BKR. MCC MLO NEC N/A NC NO PA PH PNL PVC RF SWBD SWGR SF ST TBD TD THHN THWN T/S U�I VFD WP X FM R XP M/G FRAME RATING IN AMPS ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINUM TRIP RATING IN AMPS AMERICAN WIRE GAUGE CIRCUIT BREAKER CENTRAL MANAGEMENT CONTROL SYSTEM CONDUIT ONLY DEDICATED EXHAUST FAN ELECTRICAL METALLIC TUBING ELECTRIC WATER COOLER FULL VOLTAGE, NON–REVERSING GROUND FAULT INTERRUPTER GROUND HORSEPOWER INTERMEDIATE METAL CONDUIT THOUSAND CIRCULAR MILS LOW VOLTAGE MAIN BREAKER MOTOR CONTROL CENTER MAIN LUGS ONLY NATIONAL ELECTRICAL CODE NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN PAGING SYSTEM PHASE PANEL POLY–VINYL CHLORIDE (CONDUIT) RETURN FAN SWITCHBOARD SWITCHGEAR SUPPLY FAN SHUNT TRIP TO BE DETERMINED TIME DELAY WIRE INSULATION TYPE WIRE INSULATION TYPE TWISTED & SHIELDED UNIT HEATER VARIABLE FREQUENCY DRIVE WEATHER PROTECTED TRANSFORMER EXPLOSION–PROOF MOTOR GENERATOR REFER TO N.E.C. REFER TO N.E.C. Gw1..�1 i D Uri OF TUKWILA AUG 31 2018 PERMIT CENTER CASNE E ELECTRICAL AND ENGINEERINGTECHNOLOGY CONSULTANTSINC. 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW, CASNE. COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION SMD TB JMK 03.14.96 B REPLACE 400 HERTZ GENERATORS 32317 CASNE CEC 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 C INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNEII SUBTITLE ELECTRICAL LEGEND CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNE! I APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHE E1A OB NO. MFC -95060 COMP N DWG NO. 13-03–E1A C JE SM v ABY LAND USE CODE TUKWILA, WASHINGTON ZONING MANUFACTURING INDUSTRIAL CENTER/HEAVY INDUSTRIAL (MIC/H) REPLACED IMPERVIOUS SURFACE: 0 SF (0.00 AC) ESTIMATED EARTHWORK QUANTITIES: CUT 0 CY (0 CY EXPORT) FILL 0 CY (0 CY IMPORT) TOTAL 0 CY (0 CY) DOJECT 1NFOMA1iO SCOPE OF WORK: ALL WORK APPLIES TO 13-03 BUILDING: CIVIL: PROVIDE STRUCTURAL ANCHORING FOR 400HZ GENERATORS ELECTRICAL: RE -INSTALL GPU #1 (PROVIDED BY BOEING). INSTALL A SECOND JBT 400HZ 180KVA GROUND POWER UNIT (GPU #2). PROVIDE CONDUIT AND CONDUCTORS FROM PANEL 1D6 TO GPU AND FROM GPU TO PANEL 1D6-3. PROVIDE 400HZ FEEDER PROTECTION ON EXISTING GENERATOR 1 AND NEW GENERATOR 2 OUTPUTS IN PANEL 1D6-3 GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO THE WSDOT STANDARD SPEC. 2016 EDITION, CURRENT WSDOT STANDARD PLANS, AND CITY OF TUKWILA REGULATIONS. 2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK AND SHALL NOTIFY THE BOEING PROJECT MANAGER OF ALL DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS. 3. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. BOEING CONTACT: SUNG CHO FACILITIES ENGINEER P. 0. BOX 3707, MS 46-87 SEATTLE, WA 98124-2207 TELEPHONE: 206-612-6953 VERTICAL DATUM: NAVD 88 BENCHMARK: CITY OF SEATTLE SNV-5296 BRASS CAP 25' S OF WHEELCHAIR RAMP AT SE CORNER OF INTERSECTION OF E MARGINAL WAY S AND S 96TH PL ELEVATION = 18.14' N NCR AS BOF 00 / POW -H SYS O8// SSS/9 BOEING MILITARY FLIGHT CENTER 10002 EAST N/ARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 vcr\ ITY MA PROJECT SITE FROM DOWNTOWN SEATTLE 900 99 \\ OXBOW 3'IPGE EXIT 158 OXBOW LOT EXIT 157 - 99 EAST MARGINAL WAY CORPORATE PARK FRON SEATTLE -TACOMA AIRPORT DEVELOP v E\TAL 599 TUKWILA TES FROM KENT & AUBURN NO SCALE EXIT I57 900 AREA MA SITE A 100C2 EAST v1AKl Li <W I LA, WA J J CESS: \AL WAY SOUT S-I\GTO\ PROJECT SITE 7-251 OXBOW PARKING LOT LOOHZ GPU EPLACEv E\ TL CATIO\ NO SCALE M IN SET DRAWING # SHEET # DRAWING TITLE REV DATE GENERAL • 13 -003 -GO GO COVER SHEET - 08.10.18 ELECTRICAL • 13-003-E1A E1A ELECTRICAL LEGEND C 08.10.18 • 13-003-E1B E1B NOTES, SYMBOLS AND ABBREVIATIONS - 08.10.18 • 13-003-1E4AR 1E4AR ONE LINE DIAGRAM - 60 HZ POWER (REMOVAL) B 08.10.18 • 13-003-1E4ER 1E4ER ONE LINE DIAGRAM 400 HZ POWER SYSTEM (REMOVAL) E 08.10.18 • 13-003-1E2R 1E2R 480 VOLT MAIN POWER PLAN (REMOVAL) C 08.10.18 • 13-003-1E160R 1E16OR 400HZ & 28V DC POWER PLAN (REMOVAL) D 08.10.18 • 13-003-1E4A 1E4A ONE LINE DIAGRAM - 60 HZ POWER B 08.10.18 • 13-003-1E4B 1E4B ONE LINE DIAGRAM - 60 HZ POWER D 08.10.18 • 13-003-1E4E 1E4E ONE LINE DIAGRAM 400 HZ POWER SYSTEM E 08.10.18 • 13-003-1E2 1E2 480 VOLT MAIN POWER PLAN C 08.10.18 • 13-003-1E9 1E9 GROUNDING C 08.10.18 • 13-003-1E160 1E160 400HZ & 28V DC POWER PLAN D 08.10.18 • 13-003-2E160 2E160 400HZ & 28V DC POWER PLAN F 08.10.18 • 13-003-E508 E508 DETAILS D 08.10.18 • 13-003-E524 E524 DETAILS 400HZ & ANTENNA ALARM PANEL E 08.10.18 • 13-003-E535 E535 LAYOUTS 1ST / 2ND / 3RD FLOORS C 08.10.18 LL18 07 S8 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED FOR— COMPLIANCE WITH NFPA70 - NEC SEP 2 8 2018 City of Tukwila BUILDING D I(3t\1 RECEIVED CITY OF TUKWILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.03.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. KREISCHER DATE 11.28.16 CHECKED B. LESLIE ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED 11.28.16 02.01.17 SUBTITLE COVER SHEET CURRENT REVISION 35379 SYMBOL DATE 08.10.18 02.01.17 TITLE GENERAL INCREASE 400HZ POWER SYSTEM 13-YRD M.F.C. SHEET GO JOB NO. DWG NO. 35379 13-003-G0 COMP NO. '0 D SL MMAY LAND USE CODE TUKWILA, WASHINGTON ZONING MANUFACTURING INDUSTRIAL CENTER/HEAVY INDUSTRIAL (MIC/H) REPLACED IMPERVIOUS SURFACE: 0 SF (0.00 AC) ESTIMATED EARTHWORK QUANTITIES: CUT 0 CY (0 CY EXPORT) FILL 0 CY (0 CY IMPORT) TOTAL 0 CY (0 CY) POJ CT I aWATI N SCOPE OF WORK: ALL WORK APPLIES TO 13-03 BUILDING: CIVIL: PROVIDE STRUCTURAL ANCHORING FOR 400HZ GENERATORS ELECTRICAL: RE—INSTALL GPU #1 (PROVIDED BY BOEING). INSTALL A SECOND JBT 400HZ 180KVA GROUND POWER UNIT (CPU #2). PROVIDE CONDUIT AND CONDUCTORS FROM PANEL 1D6 TO GPU AND FROM GPU , TO PANEL 1D6-3. PROVIDE 400HZ FEEDER PROTECTION ON EXISTING GENERATOR 1 AND NEW GENERATOR. 2 OUTPUTS IN PANEL 1D6-3 GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO THE WSDOT STANDARD SPEC. 2016 EDITION, CURRENT WSDOT STANDARD PLANS, AND CITY OF TUKWILA REGULATIONS. 2, THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK AND SHALL NOTIFY THE BOEING PROJECT MANAGER OF ALL DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS. 3. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. BOEING CONTACT: SUNG CHO FACILITIES ENGINEER P. 0. BOX 3707, MS 46-87 SEATTLE, WA 98124-2207 TELEPHONE: 206-612-6953 VERTICAL DATUM: NAVD 88 BENCHMARK: CITY OF SEA! I LE SNV-5296 BRASS CAP 25' 5 OF WHEELCHAIR RAMP AT SE CORNER OF INTERSECTION OF E MARGINAL WAY S AND S 96TH PL ELEVATION = 18.14' A BO VC\TY MA 400 NG 10441,, / PO - R SVS 08# J5J/9 BOEING MILITARY FLIC-- CENER 10002 EAST MARGINAL WAY SOUTH TU<WILA, WASHINGTON 98108 PROJECT SITE SI ADDRESS: EAST VARGI\AL WAY SO 'KWILA, WAS-I\GTO\ FROM DOWNTOWN SEAI ILE D❑ 900 u) PROJECT SITE OXBOW :'ISGE EXIT EXIT 158-� 158 MILITARY FLIGHT CENTER OXBOW LOT 4 EXIT 157 EXIT 157 EAST MARGINAL WAY CORPORATE PARK 599 TUKWILA FROM KEI\ & AUBUR 900 99 FROM SEM I LE—TACOMA AIRPORT OXBOW PARKING LOT 3 -V-Lo v \TAL C TES NO SCALE 400H7 GPU PLACEV=\T LOCA NO SCALE IN SET DRAWING # SHEET # DRAWING TITLE REV DATE GENERAL • 13 -003 -GO GO COVER SHEET - 08.10.18 ELECTRICAL • 13-003-E1A E1A ELECTRICAL LEGEND C 08.10.18 « 13-003-E1B E1B NOTES, SYMBOLS AND ABBREVIATIONS - 08.10.18 • 13-003-1E4AR 1E4AR ONE LINE DIAGRAM - 60 HZ POWER (REMOVAL) B 08.10.18 • 13-003-1E4ER 1E4ER ONE LINE DIAGRAM 400 HZ POWER SYSTEM (REMOVAL) E 08.10.18 • 13-003-1E2R 1E2R 480 VOLT MAIN POWER PLAN (REMOVAL) C 08.10.18 • 13-003-1E160R 1E16OR 400HZ & 28V DC POWER PLAN (REMOVAL) D 08.10.18 • 13-003-1E4A 1E4A ONE LINE DIAGRAM - 60 HZ POWER B 08.10.18 • 13-003-1E4B 1E4B ONE LINE DIAGRAM - 60 HZ POWER D 08.10.18 • 13-003-1E4E 1E4E ONE LINE DIAGRAM 400 HZ POWER SYSTEM E 08.10.18 • 13-003-1E2 1E2 480 VOLT MAIN POWER PLAN C 08.10.18 • 13-003-1E9 1E9 GROUNDING C 08.10.18 • 13-003-1E160 1E160 400HZ & 28V DC POWER PLAN D 08.10.18 • 13-003-2E160 2E160 400HZ & 28V DC POWER PLAN F 08.10.18 • 13-003-E5O8 E508 DETAILS D 08.10.18 • 13-003-E524 E524 DETAILS 400HZ & ANTENNA ALARM PANEL E 08.10.18 • 13 -0O3 -E535 E535 LAYOUTS 1ST / 2ND / 3RD FLOORS C 08.10.18 FILE COPY Permit No. E S- 075'6 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Rccoipt of approved Field Copy and conditions is acknowledged: ©y: Date: // / ,, J, ., City of Tukwila BUILDING DIVISION REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division NOTE: Ravisicns will require a new plan submittal and may include aonal plan review fees, SEP, Ai IA I E PERMIT REQUIRED FGR» 1 chanicai 0 Electrical <umbing [- as Piping Ciiy of Tukwila B IILPING DIVISION ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED FOR COMPLIANCE WITH NEPA 70 - NEC SEP 2 8 2018 City of ukwila BUILDING DIVISION RECEIVED CITY TY OF TUKVVILA AUG 31 2018 PERMIT CENTER ECA SNE EAND TECHNOLNGINEEOGY CRINGONSU, ILTANTSNC. ELECTRICAL 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.03.18 ff..&171/!s ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. KREISCHER CHECKED B. LESLIE ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED DATE 11.28.16 11.28.16 02.01.17 SU BTITLE COVER SHEET CURRENT REVISION 35379 SYM BO DATE 08.10.18 02.01.17 TITLE GENERAL INCREASE 400HZ POWER SYSTEM 13-YRD .F.0 SHEET GO JOB NO. 35379 COMP NO. DWG NO. —003—GO LGT (LV) 1D5 1D5-1 X1D5 400 HZ DIST. PANEL 1D6-3 FRONT PANEL JETPOWER III 400HZ, 180KVA GPU1I2 (4) 4" TO SUB. 13.01 gtx NOR (4 4 — TO HANDHOLE (FOR COMMUNICATION, LOCATION TBD) 4 2" — TO EMERGENCY POWER SWITCHBOARD AND BUILDING CONTROL (TBD) 4 2" — TO DUMPSTER (REFER TO SHEET E507) (3) 3/4" — TO DUMPSTER (REFER TO SHEET E507) QUI3VVE\T LAYOUT PLA\ FIST FL. ELECTRICAL .00Iv SCALE: 1/4" = 1'-0" WctfriipiQ 1 E2,1 E3,E4A E535 LGT (LV) 2D5-2 2D5-1 2D5 75 X2D6 2D6-1 X2D6-1 2D6 EQUIRME\T LAYOUT SECO\D FLCO =L SCALE: 1/4' = 1'-0" DLA\ -CTS I CAL OOv (2� 2E2,2E3,E4B E535 LGT (LV) 3D5-2 3D5-1 3D5 /3 X3D6 3D6-1 X3D6-1 3D6 EQURVE\T TH I D FLOC) SCALE 1/4" = 1'-0" SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION SMD TB B REPLACE 400 HERTZ GENERATORS 32317 CASNE JMK CEC 03.14.96 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT C INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG 03.27.18 08.10.18 MffE7 ® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG -0" LAY C J T PLA\ ELECTS I CAL DATE CO 03 v 3E2,3E3,E43 E535 L 3 -EFEH\CE D AWI\GS ► 13-003-S503 G \HAL OTES CO\ STUCTIC \ OTES INSTALL JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT. ANCHOR TO EXISTING HOUSEKEEPING PAD PER MANUFACTURER REQUIREMENTS TO MEET IBC 2015 SEISMIC RATINGS. EL(BO75 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED Wii H COMPLIANCE NEPA 70 - NEC SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVED CiTY OF TUKWII ,, AUG 3 1 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA9H0. (425) 522-1000 wunurecur gnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, 98033 WWW. CASNE. COM NO. 181-085 CHECKED T. BENNETT SUBTITLE LAYOUTS 1ST / 2ND / 3RD FLOORS CURRENT REVISION SYMBOL 35379 C DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE 01.12.96 BUILDING 13-03 INCREASE 400HZ POWER SYSTEM ELECTRICAL ROOMS SHEET E535 JOB NO. MFC -95060 COMP NO. DWG NO. Dev. Center,Wa 13-003—E535 R1 R2 TR SPACE / ENCL1 TB1 (5) DOOR MOUNTED ITEMS: FU1 LI, L2, L3, L4, L5 51, 52, 53, S4 B1 DOOR — INSIDE CABINET — INSIDE 400 HZ AND ANTENNA TRANSMITTER ALARM PANEL SCALE: NONE ALARM PANEL COMPONENT LIST ITEM TAG QTY. DESCRIPTION MANUFACTURER/MODEL R1 1 CONVERTIBLE CONTACT RELAY, (2) 10A CONTACT CARTRIDGES, 120V, ALLEN BRADLY #700—P200B11 R2 1 CONVERTIBLE CONTACT RELAY, (4) 10A CONTACT CARTRIDGES, 120V, ALLEN BRADLY #700—P400B11 TR 1 SOLID STATE TIMING RELAY, 2 NO CONTACTS, 120V, 4 CONTACTS. ALLEN BRADLY #700—RTC00400U1 L2 1 FLASHING PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, RED LENS SQUARE D, CLASS 9001 #KXPAF1R L1,L3,L4 L5 4 PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, GREEN LENS SQUARE ' D, CLASS 9001 #KP1 G31 1 1 L1 LEGEND PLATE, BLACK WITH WITH "POWER ON" SPECIAL MARKINGS SQUARE D, CLASS 9001 #KN399 —"POWER ON" L1,L3,L4 3 PILOT LIGHT, 120 VAC, TRANSFORMER TYPE, GREEN LENS SQUARE D, CLASS 9001 #KP1G31 L6 1 SIGNALING LIGHT, CEILING MOUNTED, 120V, WHITE DOME, STAINLESS STEEL PLATE. EDWARDS #7641-1N5 L7 1 FLASHING LIGHT WITH PROTECTIVE DOME COVER. WALL MOUNTED, 120V, AMBER. EDWARDS #49A—R5 B1 1 PANEL MOUNT BUZZER, 120V. EDWARDS'S LUMATONE OR EQUIVALENT. B2 2 AMBER FLASH BEACON LIGHT WITH SEPERATE HORN. 120V, PIPE MOUNTING, WEATHERPROOF. EDWARDS #94A—N5 FU1 1 FUSEHOLDER FOR 1-1/4"x1/4" FUSE, NEON LAMP INDICATION OF BLOWN FUSE BUSSMANN #HKL—X 51, S2, S4 2 MOMENTARY CONTACT PUSHBUTTON SWITCH, 1 N.O. & 1 N.C. CONTACTS, GREEN BUTTON WITH FULL GUARD SQUARE D, CLASS 9001 #KR1GH13 SYSTEM FAULT 1 FUSE, 1-1/4"x1/4" CERAMIC TUBE, 250 V, 15 AMP, TIME DELAY BUSSMAN #MDA -15 S3 1 ON—OFF SELECTOR SWITCH. SQUARE D, CLASS 9001 SWITCH #D 2SDU 1 O LEGEND #85W2 ENCL1 1 NEMA 1, 16 GAUGE ENCLOSURE WITH WITH ENAMEL MOUNTING PANEL, HINGED DOOR WITH FLUSH HANDLE LATCH, LIGHT BLUE ENAMEL EXTERIOR HOFFMAN "A" SERIES CONTROL ENCLOSURE. SIZE: 12" W X 16" H MINIMUM TB1 6 TERMAINAL STRIP WITH 6 TERMINAL BLOCKS, BARRIER TYPE WITH MARKING STRIP, 25 AMP, SCREW TERMINALS WITH WIRE CLAMPS, #18—#12 AWG WIRE RANGE ALLEN—BRADLEY #1492—HJ86 REVISION BY APPROVED DATE SYM REVISION DOOR — OUTSIDE NAMEPLATE SCHEDULE 400 HZ MG AND ANTENNA ALARM PANEL SCHEMATIC DIAGRAM H WIRE NUMBER DESIGNATION (TYP) R1 L2 (N) N � 81 (30) S3 [17]" ---'RELAY LINE NUMBER L1 400 HZ SYSTEM FAULT INDICATOR 400 HZ SYSTEM FAULT BUZZER (N) "POWER ON" ITEM TAG QTY. SIZE COLOR LINE HR TEXT NOTES FACE TEXT NP -1 1 BLK WHT 1 1/4" 400 HZ & ANTENNA PANEL MOUNT ON FRONT OF PANEL NP -2 1 BLK WHT 1 1/8 FUSE MOUNT ON FRONT OF PANEL 2 1 /8" MDA 15 NP -3 1 GRN WHT 1 1/4" 400 HZ SYSTEM MOUNT ON FRONT OF PANEL NP -4 1 GRN WHT 1 1/8" SYSTEM FAULT ALARM MOUNT ON FRONT OF PANEL NP -5 1 GRN WHT 1 1/8" SYSTEM FAULT MOUNT ON FRONT OF PANEL NP -6 1 GRN WHT 1 1/8" ALARM RESET MOUNT ON FRONT OF PANEL NP -7 1 GRN WHT 1 1 ,> . �1 MOUNT ON FRONT : PANEL NP -8 1 GRN WHT 1 1/8" 400HZ GPU #1 ON MOS T ON FRONT OF P=NEL NP— 9 1 GRN WHT 1 /8" © 400HZ GPU #2 ON MOU - OF P ON FRONT EL NP -10 1 YEL WHT 1 1 , " ,: T , ,. .. M MO . I T ON FRONT OF PANEL NP -11 1 YEL WHT 1 1/8" PUSH TO ACTIVATE MOUNT ON FRONT OF PANEL 2 1/8" PRE—TRANSMISSION WARNING NP -12 1 YEL WHT 1 1/8" ROOF ANTENNA MOUNT ON FRONT OF PANEL 2 1/8" TRANSMITTING SIGNAL NP -13 1 YEL WHT 1 1/8" TRANSMITTING STOP MOUNT ON FRONT OF PANEL BY APPROVED DATE DCN 29 - 400 HZ AND ANTENNA PANEL SMD JK KR 23.8.96 - RECONCILED TO VAULT INCORPORATED CONST. RED -LINES MODIFIED ROOF WARNING LIGHT/HORN J#772575 -LO REPLACE 400 HERTZ GENERATOR 32317 K.DARCY 7/2/97 E INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG 03.27.18 08.10.18 K.DARCY N.MEHTA 7/14/97 CASNE CE 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 8 9 10 11 12 1 6A [8] S4 RESET 0 0 Si SPARE (FIELD INPUT) SPARE (FIELD INPUT) (7) LATCHING RELAY 16 17 18 19 20 21 22 23 24 25 26 27 [8] TR [21] S2 0 10 PRE—TRANSMISSION WARNING 12 R1 14 R2 11 13 [8] 5 11 L5 (N) L6 SPARE SPARE B2 B2 LATCHING TIMER RELAY 8] ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE [21] DRAWN S. DANG DATE CHECKED T. BENNETT -® -0 -o N "GPU #1 ON" PILOT LAMP "GPU #2 ON" PILOT LAMP 9, 16, 25, 27 MG FAULT RESET 4,23 8, 19, 27, 28 28 29 TO ANTENNA TRANSMITTER INPUT INTERLOCK (CONTACT CLOSE TO ENABLE TRANSMITTER TO START). SUBTITLE 19 TR SYMBOLS LEGEND PANEL TERMINAL BLOCK PANEL WIRING FIELD WIRING GENERAL NOTES ALL WIRES TO BE LABELED PER CONNECTED TERMINAL BLOCK NUMBER, UNLESS OTHERWISE INDICATED. REFER TO SHEET 2E60, COL. 3/C FOR LOCATION. REFER TO SHEET 2E60, COL.2/C FOR LOCATION. REFER TO SHEET 3E60, COL. 5/A FOR LOCATION. REFER TO SHEET RFE60, COL. 5/A—B FOR LOCATION. CO\ST CTIO \OT -S PROVIDE UPDATED CONTROL PANEL LABEL WITH GPU #. MATCH EXISTING FONT TYPE, COLOR AND SIZE. PROVIDE CONTROL PANEL LABEL. MATCH EXISTING FONT TYPE, COLOR AND SIZE. RECONNECT EXISTING WIRING TO GROUND POWER UNIT #1 STATUS CONTACTOR. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR DETAILS. CONNECT SPARE WIRING TO GROUND POWER UNIT #2 STATUS CONTACTOR. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR DETAILS. 21 20 EL1B ISSUE FOR CONSTRUCTION AUGUST 10, 2018 DETAILS 400 HZ & ANTENNA ALARM PANEL SPARE 075 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 8 2018 City of •Tukwila BUILDING DIVISION RE-:CEi\r E0 CiTY OF TUKWILJ.\ AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION SYMBOL 35379 DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 SHEET E524 JOB NO. MFC -95060 COMP NO. DWG NO. Dev. Center,Wa 13-03—E524 FINISH FLOOR SLAB 8'-0" MAX EQUAL EQUAL SYMEITRIC H Z' DISCONNECT SWITCH _JUL P3301 HORIZ12—TOTAL ( ) CENTER AT P3000 VERTS 6" CLEAR TRANSFORMER OR DC POWER SUPPLY. 650 LBS MAX WT. (2—TOTAL) P1047 EA END OF EA SLEEPER AT P3301 P3000 SLEEPERS (3) MIN PER UNIT JZ _Z 1" MAX TYP J / // / E534 ABOVE CEILI NOT TO SCALE NON—SECURED AREA WALL P3000 DIAGONAL WITH 3/8" DIA MACHINE SCREW AT EA P3301 HORIZ (6—TOTAL) P3301 HORIZ (12—TOTAL) CENTER AT P3000 VERTS WITH P2484W EA END TYP NOTE: ALL FRAMING COMPONENTS SHALL BE UNISTRUT P1379S CLAMP TYP P3000 VERT TYP P1379S CLAMP EA SIDE FLANGE WIDE FLANGE FLOOR OR ROOF BEAM \G TRANSFORMER & DC POWER SUPPLY SUPPORT m E2 SERIES E508 SECURED AREA TRUSS, BLDG. STEEL, ETC. T&B PART #3122 CONDUIT HANGER (TYPICAL) TYPICAL CONDUIT PASSING THRU PROGRAM BOUNDARY FOR FIRE RATED WALLS, INSTALL 3M #FS 195 FIRE BARRIER ON EACH SIDE OF WALL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS BONDING STRAP (2 PLS — TYP) OZ PART #GF19G 1/2"-1" PVC SECTON — EXTEND 3" MINIMUN BEYOND FIRE STOP ASS'Y ON EACH SIDE OF WALL BONDING REQUIRED ON BOTH SIDES OF PVC SECTION TO BUILDING STEEL. EACH SIDE OF PVC SECTION MUST BE BONDED SEPARATELY. #12 AWG MIN. BONDING REQUIRED ON ALL CONDUITS et BONDING WIRE SIZE SHALL BE PER N.E.C. 250-79d. SECURED TO SON -SECURED CONDUIT DETAIL NOT TO SCALE REVISION BY APPROVED DATE SYM 2 P1728 TYP 1" TYP A Lal U P3000 SLEEPER (3) MIN PER TRANSFORMER P3000 WITH P1047 AT EA VERT P2484W TOP AND BOT OF P3000 VERTS NOTES 1. TAKE RESISTANCE MEASUREMENTS BETWEEN EACH CONDUIT AND THE STRUCTURE TO WHICH IT IS BONDED AT, A POINT NEAR EACH BONDING STRAP. RESISTANCE NOT TO EXCEED 0.005 OHMS (5 MILLIOHMS). 4 1 AX 1'-0" P3000 2. RESISTANCE MEASUREMENTS FOR CONDUITS AT ALL BONDING STRAPS TO BE RECORDED AND PROVIDED TO THE BE&CE CONSTRUCTION MANAGER UPON COMPLETION OF INSTALLATION. 3. AS BUILT DRAWINGS SHOWING LOCATION OF ALL BONDING STRAPS TO BE PROVIDED TO THE BE&CE CONSTRUCTION MANAGER UPON COMPLETION OF INSTALLATION. 2E2,2E60,2E1601E508 REVISION APPROVED DATE DISCONNECT SWITCH • • • • r • FINISH FLOOR SLAB P3301 HORIZ TYP (2) AT EA FLUTE P2484W AT EA P3301 P3000 VERT TYP OUTLINE OF TRANSFORMER (NOT SHOWN) 0 0 0 • • r �r i L • • • • P3000 DIAGONAL 3/8" MACHINE SCREW AT EA P3301 (6—PLACES) NOTE: ALL FRAMING COMPONENTS SHALL BE UNISTRUT SECTION r -A - E508 P1379S CLAMP EA SIDE FLANGE TYP P1047 TYP P3000TYP P3301 HORIZ TYP P2484W TYP (24—TOTAL) LEGEND: GENERAL NOTES: REVIEWED WITH COMPLIANCE 70 - NEC SEP 2 8 2018 CONFIGURATION DEPENDENT ON FEEDER CALL OUT ON REFERENCING DRAWING r ECEIti 0 CTYOFTUKWILA 400 HZ SPIRAL WOUND CABLE CONFIGURATION / 3 ISSUED FOR CONSTRUCTION SD TB MOD. E37 PWR. PNL 400HZ 10D1521234 VAVREK REPLACE 400 HERTZ GENERATORS RECORD DRAWING 32317 CASNE 32317 RECONCILED TO VAULT CASNE NO JMK VAVREK 03.14.96 02.15.05 D INCREASE 400HZ POWER SYSTEM 35379 CASNE 08.10.18 FOR REFERENCE ONLY ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY CEC 02.01.17 06.26.17 03.27.18 DEPT. DATE DRAWN S DANG DATE CHECKED T BENNETT ENGINEER S DANG CHECKED T BENNETT SUBTITLE ISSUE FOR CONSTRUCTION AUGUST 10, 2018 DETAILS CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION 35379 SYMBOL 3 DATE 08.10.18 APPROVED J KOKOCZKA APPROVED K RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHEET E508 JOB NO. COMP NO. DWG NO. 13-003—E508 1 CONVENIENCE OUTLETS 400—HZ 2C1-1 Cc 15 2A4-3/1 a 1/2" RAC 30 ALUMINUM CONDUIT 3/4" C., (5) #8 2A4-3/ 190,211D,23 THIS BOX' REPRESENTS THE WORKING 2A4-3 15 X 9 730 SUPPLY NTL -18 THESE WILL BE WALL MOUNTED (NOT UNDERFLOOR) 200 200 3 —11 3/4 CLEARANCE REQ'D BY THE N.E.C. IT MUST NOT BE OCCUDIED BY ANY OTHER EQUI' ACCEPTABLE?? 2D1 1"RAC-4#6, 1118 GRD. 201/26,28,30 D\ 60A/NF UNDERFLOOR J—BOX 7 TYPICAL AIRCRAFT PWR. DISTBN. CTR. CUSTOMER SUPPLIED STINGER CABLE X TO 400 HZ DISTRIBUTION PANEL 106-3. SEE DWG. E4E 400HZ & ANTENNA ALARM PANEL 1/2"C 3#12 400HZ GPU#2 STATUS 1/2"C 3#12 400HZ GPU#1 STATUS 9 MOM 1111111. OWN 1] L 9 F X 0 i D 2D4-1 I9> u Jr SECO\D FLOOR DLA\ SCALE: 1/8' 1/8'=l' (i) Ll 8- 0755 (TE8jH' _COi INPLIA NFPA 70 - NEC SEP 28 2018 City of Tukwila BUILDING DIVISION LEGEND: REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA `'' 20 20 200Y/115 4 5 HUBBELL 3520 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 160 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 +1 ti 28 VDC PANEL. 400 HZ PANEL. GEN ERAL \OTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400HZ HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 400HZ A 0 (LEFT BUS IN PNL) B 0 CENTER BUS IN PNL) C 0 RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN RED BLACK GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. 1 9 > REFER TO SHEETS E512 AND E513 FOR COMPUTER RECEPTACLES AND POWER REQUIREMENTS FOR THIS ROOM. CO\STJCTIO\ \OTES PROVIDE UPDATED ANNUNCIATOR PANEL LABELS. SEE E524 FOR DETAILS. TERMINATE EXISTING SPARE WIRING FOR GPU #2 STATUS. SEE E524 FOR DETAILS. REFERENCE DRAWINGS 13-003-1E160 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 13-003—E524 RECEIVES) MY OF _i UK'vVILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION RECORD DRAWING 32317 B C D E NATO AWACKS INTEG. LAB PROVIDE POWER NATO LAB 13.03.02 MOD. E37 PWR. PNL. 400HZ REPLACE 400HZ GENERATORS 170097-01 792351-00 1001521234 32317 DEH JDH VAVREK CASNE JV AW WHITSON VAVREK CEC 06.19.98 08.12.99 02.14.05 02.01.17 RECONCILED TO VAULT F INCREASE 400HZ POWER SYSTEM 35379 CASNE NO CASNE SHG RM SHG 06.26.17 03.27.18 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN T. BENNETT DATE CHECKED S. DANG ENGINEER SUBTITLE 400 HZ & 28V DC POWER PLAN CURRENT REVISION SYMBOL 35379 DATE 08.10.18 T. BENNETT CHECKED S. DANG APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. A—H/1-7 Dev. Center,Wa SHEET 2E160 JOB NO. MFC -95060 COMP NO. DWG NO. 13-003-2E160 (5) -EC REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND HZ SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA 400 ="' 20 20 200Y/115 4 5 HUBBELL 3520 400 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 400 60 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 400 IV 15 15 115 2 3 HUBBELL 7487 DC 1-0 20 20 28 2 3 HUBBELL 6810 1D i —2/38,40,42 28 VDC PANEL. 400 HZ PANEL. UP TO 2C1-1/9,11,13,1 1 D6-3/ 14a,16b,18t 6# 1 /0+1 /OG(SPIR, L) 1D1-2/32,34,36 ,/ 1D1-2/ a,3b,5 1 11-2/7a,9b,1 GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400H2 HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: (3) 400HZ A 0 (LEFT BUS IN PNL) B (CENTER BUS IN PNL C (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 1 D1 -2/19a,21 b,23c 1 D1-2/13a,15b,17c 1 D1-2/2a,4b,6c D1-2/8a,10b,12 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND RED BLACK GREEN 2D1/1 a,21b,23c 20a,22b, 2C1-1/9,11 & 13,15 101-2/25a,27b,29c 1D1 -2/39b 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. CO\STUCTtON 400 I- Z PANEL 1D6-3 (1) 4"C 7#500KCMIL, JETPOWER III --� 400HZ GPU #1 180KVA 1 1/2"C PARALLELING CONTROL CABLES JETPOWER III OOHZ GPU #2 180KVA \OTES INSTALL JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT PER MANUFACTURER REQUIREMENTS. UNIT PROVIDED BY BOEING. PROVIDE CU XHHW SPIRAL WOUND CONDUCTORS AND RIGID ALUMINUM CONDUIT ROUTED OVERHEAD AND SIZED AS SHOWN. 1/2"C 3#12 4 400HZ GPU#1 STATUS TO ANNUNCIATOR PANEL 1/2"C 3#12 4 400HZ GPU#2 STATUS TO ANNUNCIATOR PANEL EVIEVVEDYFOR COMPLIANCE WITH NFPA 70 m NEC SEP 2 8 2018 of .Tukwila BUILDING DIVISION RE—USE EXISTING CONDUIT AND CONDUCTORS WHERE POSSIBLE. PROVIDE CONDUCTORS AND CONDUIT TO RECONNECT EXISTING STATUS AND COMMUNICATION WIRING TO NEW GROUND POWER UNIT. TERMINATE CONNECTIONS PER MANUFACTURER INSTRUCTIONS. PROVIDE CONDUIT AND INSTALL JTP3 PLUS PARALLELING KIT CABLES. CABLES PROVIDED WITH JTP3 PLUS GROUND POWER UNITS. INSTALL PER MANUFACTURER INSTRUCTIONS. 0 4 8 16 24 =IRS -LOGE' P SCALE: 1/8"- _A . EFER \ICE DRAWING 13-003-2E160 ;LI 76"" C:ETY OF TU;KWIL%A AUG 31 2018 P,E R M I I C:1 ('i ft A SCALE: 1/8"=1'-0" ISSUE FOR CONSTRUCTION AUGUST 10, 2018 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION 0 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 8 RELOCATE OUTLETS J#771978—LO K. DARCY 6/02/97 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE C REPLACE 400 HERTZ GENERATORS RECORD DRAWING 32317 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 DRAWN T. BENNEI CHECKED S. DANG DATE SUBTITLE 400 HZ & 28V DC POWER PLAN ENGINEER T. BENNETT CHECKED S. DANG TITLE INCREASE 400HZ POWER SYSTEM CABINS ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM J08 NO. 181-085 CURRENT REVISION 35379 SYMBOL DATE 08.10.18 SHEET APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 ELECTRICAL MASTER BUILDING 13-03 COL. A—H/1-7 1E160 Dev. Center,Wa JOB NO. DWG NO. COMP NO. 2 C3J 6 INSULATED GROUND CABLE (GREEN #6 INSULATED GROUND CABLE (GREEN) Li— 0-) JETPOWER III 400HZ GPU 1 18OKVA JETPOWER III 400HZ GPU 2 180KVA —1 #4/0 CU TO BUILDING STEEL OVERHEAD #4/0 CU TO BUILDING STEEL OVERHEAD SWITCHBOARD BUS BAR LL MOUN ED 2 X6" 'CADWELD' OUND BAR AT 14" AFF WITH 2700V U LATO R. #4/0 TO GROUND GRID. -RST FLOOD DLA\ SCALE: 1/8" = 1'-0" #4/0 BARE GRD CABLE 0758 LEG GE EXOTHERMIC WELD GROUND CABLE CONNECTION TO GROUND BAR OR STEEL COLUMM. SAL \OTES: REFER TO SPECIFICATION SECTION 16450, SECONDARY GROUNDING. WHERE GROUND CONDUCTORS ARE RUN IN RIGID CONDUIT, CONDUCTORS MUST BE BONDED TO EACH END OF CONDUIT PER N.E.C. CONDUIT: ABOVEGROUND: UL 6, HOT—DIP GALVANIZED RIGID STEEL UNDERGROUND AND EMBEDDED IN CONCRETE: RIGID GALVANIZED CONDUIT WITH 40 MIL PVC JACKET CONDUIT FITTINGS: FOR RIGID CONDUIT: UL 514B, GALVANIZED FOR PVC COATED CONDUIT: RIGID GALVANIZED STEEL WITH 40 MIL PVC JACKET 6. WIRE: BARE: COPPER, STRANDED INSULATED: COPPER, STRANDED PER NEMA WC 5; TYPE THHN/THWN, 600 VOLT INSULATION CO \S R C 10\ NOTES BOND 400HZ GROUND POWER UNIT GROUND BUS TO BUILDING STEEL OVERHEAD WITH #4/0 CU BONDING JUMPER. SEE MANUFACTURER INSTALLATION INSTRUCTIONS FOR GROUNDING TERMINATION LOCATION. RE—ATTACH EXISTING GROUNDING CONDUCTOR TO GROUND POWER UNIT #1 GROUND BUS. REVIEWED FOR COMPLIANCE IECT�I NFPA SEP 2 8 2018 16' City Tf kwila BUILDING DIVISION_ ISSUE FOR CONSTRUCTION AUGUST 10, 2018 CE Y OF .} UKi!VILA AUG 31 2018 PERMIT CENTER E ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A B C ISSUE FOR CONSTRUCTION REPLACE 400 HERTZ GENERATORS RECORD DRAWINGS RECONCILED TO VAULT INCREASE 400HZ POWER SYSTEM SMD TB JMK 03.14.96 32317 CASNE CEC 02.01.17 32317 CASNE SHG 06.26.17 NO RM 03.27.18 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNLI1 SUBTITLE GROUNDING CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNEII APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL A—H/1-7 Dev. Center,Wa SHEET 1E9 JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E9 SYM REVISION BY 1E2 E508 ([T, T 145 100/NF45 100/NF IN SLAB 1 D6-1/2,4,6 IN SLAB 1D6-1/8,10,12 APPROVED DATE SYM E) 0 REVISION i 1D1 J4) IN SLAB 1 D6/1,3,5 N BY 75 45 30 U 0 1D5 1D6-1/7,9,11 03> D4 MCC 1D5 1D6-1/13,15,17 X1 D7/1,3,5 1D6,-1/14,1 400 HZ PN 106-3 W 2'X2' NEMA 1 PULL BOX 106/37,39,41 JETPOWER III 400HZ GPU #2 180KVA DISCONNECT ERST FLOO PLA\ SCALE: 1/8"=1 —0" APPROVED DATE A ISSUED FOR CONSTRUCTION 03.14.96 B REPLACE 400HZ GENERATORS 32317 D. OTTEN DLO 01.16.17 C INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 • •` <A4> \ &(2)4" SPARE \ • TO SOUTH SUB 93F3 HANDHOLE TO SITE EMERG. PANEL—X IN SOUTH SUBSTATION 4"C-4#4/0 & 2G (3)4"C—SPARE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG 8' 4' 0 4' 8' 16' SCALE: 1 /8"=1'-0" 11 g DATE CHECKED T. BENNETT SUBTITLE REVIEWED F UNFPA 9E� � SEP 2 8eN2018 City of Tukwila DIVISION BUILDING Li 8- 0 iS BUILDING_.� LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND RACEWAY TYPE DESIGNATION — REFER TO SINGLE LINE DIAGRAM E4 FOR RACEWAY SCHEDULES DJ 60 NF ©45 ET; 45 480Y/277 V, 3—PHASE, 4—WIRE PANELBOARD DISCONNECT SWITCH — RATING AS SHOWN SWITCH RATING/FUSE RATING (NF=NON—FUSED) DRY TYPE TRANSFORMER — SIZE AS NOTED CEILING MOUNTED DRY TYPE TRANSFORMER — SIZE AS NOTED GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES 2" AND ABOVE AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B (CENTER BUS IN PNL) RED ORANGE C (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS r. �0 \ST'„CTIO\ \CTES PROVIDE CU CONDUCTORS, OVERHEAD CONDUIT AND SUPPORTS FROM PANEL 1D6 TO 400HZ GROUND POWER UNIT #2. RE—USE EXISTING CONDUIT AND CONDUCTORS TO RECONNECT 400HZ GROUND POWER UNIT #1. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2” 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 (M4) 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 F6 250A 1 3" 3#250MCM 250MCM #2 (I,5 100A 1 1-1/4" 3#2 . #2 #6 #6 50A 1 1" 3#8 #10 e 4 ; IA 501`' V 0 2 ;, 0 ® 250A 1 2-1/2" 3#250MCM #4 F4 225A 1 2-1/2" 3#4/0 #4/0 #2 A4 1600A 4 4" 3#600MCM 600MC,l/rr. 11499_1 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 480 VOLT MAIN POWER PLAN CiTY OF TUKWILAA: AUG 31 2018 PERMIT CENTER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98 . (425) 522-1000 wrtw �d CNG gnu JOB NA ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th 205 KIRKLAND, WA 98033 WWW.CASNE.COM NO. 181-085 CURRENT REVISION SYMBOL 35379 C DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. XA—H/1-7 DEV. CENTER, WA SHEET 1E2 JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E2 OTTEND: 5/31/2017 3:40:48 PM CO\ST,CTIO\ \ OTES PROVIDE CU CONDUCTORS, CONDUIT AND ANCILLARY HARDWARE. INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (GPU) PROVIDED BY BOEING. CONNECT TO PANEL 1D6 AND 1D6-3 AS SHOWN. PROVIDE CU XHHW SPIRAL WOUND CONDUCTORS AND RIGID ALUMINUM CONDUIT SIZED PER FEEDER SCHEDULE. RE—USE EXISTING CONDUIT WHERE POSSIBLE. REFER TO E508 AND BOEING 400HZ WIRING SPECIFICATION FOR WIRING DETAIL. DO NOT TOUCH EXISTING LINE DROP COMPENSATORS (LDCs). CONTRACTOR SHALL BE LIABLE FOR ANY DAMAGE TO LDCs. VERIFY VOLTAGES AT LOAD LOCATIONS AFTER COMPLETING INSTALLATION AND COORDINATE WITH BOEING IF ANY ADJUSTMENTS ARE REQUIRED. PROVIDE CONDUCTORS AND CONDUIT TO RECONNECT EXISTING STATUS CONTACT WIRING TO NEW GROUND POWER UNIT. TERMINATE CONTACT CONDUCTORS PER MANUFACTURER INSTRUCTIONS. PROVIDE "DUAL MOUNTED HARDWARE KIT" FOR EXISTING SWITCHBOARD 1 D6-3. PROVIDE 600A 3PH GE TYPE THJK BREAKER IN EXISTING SWITCHBOARD 1D6-3. POST BREAKER DERATING TABLE INSIDE PANEL DOOR. DERATING TABLE PROVIDED WITH SPECIFICATION SET. PROVIDE CONDUIT AND JTP3 PLUS PARALLELING KIT CABLES. CABLES PROVIDED WITH JTP3 PLUS GROUND POWER UNITS. INSTALL PER MANUFACTURER INSTRUCTIONS. 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH 55' 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH XX" 180 KVA/144 KW 200/115V, 400 HZ 3 PH, 4 W OUTPUT 1-1/2"C C PARALLELING CONTROLS 180 KVA/144 KW 200/115V, 400 HZ 3 PH, 4 W OUTPUT 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS PANEL D6-3 - MAIN 400 HZ POWER DISTRIBUTION SWITCHBOARD WITH LDC 200/115 VOLT, 3000 A, 400 HZ, 3 PH, 4 WIRE (6,000 AIC AT 400 HZ) 1 (TYPICAL ALL BREAKERS) 175400 AF 400 AF 400 AF 400 AF AF ) AT / 175 AT / 175 AT / 175 AT / 175 AT LINE DROP COMPENSATOR 6% TAP 45 KVA 45 KVA 45 KVA 45 KVA 45 KVA SPARE U8 1 (TYP) Est. 120' Est. 125' 8 PNL 1D1-2 200Y/115V 200A MBKR 400 HZ 6 PNL 2D1 200Y/115V 200A MBKR 400 HZ Est. 145' 8 6> PNL 2A4-3 200Y/115V 200A MBKR 400 HZ Est. 75' 8 6 i PNL 2D4-1 200Y/115V 200A MBKR 400 HZ r T8 400 AF 300 AT 400 AF 300 AT LINE DROP COMPENSATOR 6% TAP 400 AF 300 AT 400 AF 300 AT 75 KVA 175 KVA 175 KVA 175 KVA 175 KVA I 400 AF 300 AT SPACE FOR FUTURE BRKS. 400 AF (2 MIN) Est. 125' 8 O Est. 125' 8 Est. 125' 8 O Est. 125' UNDER FLOOR J—BOX TYP. OF 4 SEE 2E160 POWER DISTRIBUTION UNIT PDU #1 POWER DISTRIBUTION UNIT PDU #2 -I L -1 AVIONICS INTERGRATION LAB LAB #1 Est. 140'-155" FEEDERS PARALLELED IN JUNCTION BOX 1-1 200/200 200 NATO AVIONICS INTERGRATION LAB 2nd Floor Q Col. B2 REVIEWED FOR COMPLIANCE ITO I FPA7 SEP 2 8 2018 Clh► of.TukWUa I. DING DIV SI.N LEGE\D GE \E BREAKER WITH 120V SHUNT TRIP SAL \ OTES ALL CONDUITS AND FITTINGS FOR 400 HERTZ CABLING TO BE ALUMINUM AND SHALL BE ARRANGED WITH MAXIMUM PHYSICAL SEPARATION FROM COMMUNICATION RACEWAYS AND OTHER CABLES. 400HZ GEN AND DISTRIBUTION SWITCHBOARD INPUT/ OUTPUT CIRCUIT BREAKERS TO BE SPECIALLY MANUFACTURED WITH CALIBRATION FOR 400 HZ SYSTEM APPLICATION. ALL 400 HZ FEEDERS TO HAVE 90°C, TYPE XHHW-2 INSULATION UNLESS OTHERWISE NOTED. 400 HZ FEEDERS TO BE IN A SPIRAL WOUND CONFIGURATION. REFER TO DETAIL 3, SHEET E508. INSTALLED IN 400HZ DISTRIBUTION SWITCHBOARD. FRONT ACCESS. 6 > 120V SHUNT TRIP MAIN BREAKER BREAKER EQUIPTED WITH N.O. AND N.C. AUX CONTACTS. 8 > FEEDER LENGTHS SHOWN ARE APPROXIMATE. 4 >3 4> 4 4 i 3 4 3 FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG ® 250 A 1 2-1/2" 3-250 MCM #4 F4 600A 1 4" 6-500 MCM #500MCM #2/0 10)3 200 A 1 2-1/2" 6 #1/0 #1/0 #3 U8 175 A 1 2" 6 #2 #2 #4 ® 300A 2 2 1/2" 3— #4/0 #4/0 #3 W8 200 A 1 2 1/2" 3— 4/0 4/0 #3 p Y, *fttey ,Cis a i..::,i- Aura 1"111.! 1 ?bR4R ISSUE FOR CONSTRUCTION AUGUST 10, 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTUCTION SMB TB JMK 03.14.96 RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED B C D DCN 29 - REVISE PER MANUF. DESIGN NATO AWACS INTEGRATION LAB J#170097 REPLACE 400 HERTZ GENERATORS 32317 SD TB DEH JK KR JV/AW CASNE CEC 8.23.96 E INCREASE 400HZ POWER SYSTEM 35379 CASNE 08.10.18 APPROVED BY DEPT. DATE 02.01.17 \e' RECORD DRAWING 32317 CASNE SHG 06.26.17 DRAWN S. DANG DATE SUBTITLE CHECKED T. BENNEII ENGINEER S. DANG TITLE ONE LINE DIAGRAM 400 HZ POWER SYSTEM CURRENT REVISION 35379 SYMBOL E DATE 08.10.18 SHEET REPLACE 400 HERTZ GENERATORS CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI BUILDING 13-03 E4E JOB NO. 02.12.95 ELECTRICAL MASTER Dev. Center,Wa DWG NO. COMP NO. MFC -95060 13-03—E4E OTTEND: 03/07/16 10:42 / co / 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PANEL 1 D6 - MAIN DISTRI3UTION SWITCH3OAKD @ BLDG. 13-03, COL. D/6 LT ST GF 800 AF 800 AT PNL 2D5-1 150 A MAIN 3PH, 4W PNL 2C1 150 A MAI N 3PH, 4W PNL 2D5 800 A MAIN 3PH. 4W ///// PNL 2D5-2 150 A MAI N 3PH, 4W LIGHTING PNL 2A4 150 A MAI N 3PH. 4W (F76) K13 HLC 75 KVA - N 208Y/120 V J 100A K50 HLC -i-V-Y--45KVA b -1 100A EJ 100A -1100A K50 K50 K13 HLC HLC HLC A U`"J`J 45 KVA A �/�' 45 KVA �A "UJ 45 KVA _0,..-6,7;i...3_0,..-6,7;i...3�MI + 1 r 208Y/120 V 208Y/120 V 208Y/120 V 208Y/120 V PNL 2A4-1 100A M. BKR. 3PH, 4W HOUSE HOUSE HOUSE COMPUTER IG COMPUTER COMPUTER IG COMPUTER IG PNL 2D4-2 100A M. BKR. 3PH, 4W COMPUTER IG LT ST GF 800 AF 800 AT PNL 3D5-1 250 A MAI N 3PH, 4W K13 HLC - ------ 30 KVA 208Y/120 V PNL 2D6-1 100 A M. BKR. 3PH, 5W COMPUTER DATA CLOSET 226D5 PNL 3D5-2 150 A MAIN 3PH, 4W LIGHTING PNL 3D5 800 A MAIN 3PH, 4W LT ST GF 0 SPARE PNL 3C1 150 A MAI N 3PH, 4W 600 AF 500 AT LT ST GF 600 AF 500 AT SPARE LT ST GF 400 AF 250 AT LT ST GF 800 AF 800 AT MCC 1D5 800 A M.L.O. 3PH, 4W SEE SHEET E4C FOR 1 -LINE K13 HLC 75 KVA -fo rrrn 208Y/120 V LT ST GF 225 AF / 225 AT PANEL -X/19,21,23 SOUTH SUBSTATION EMERGENCY PANEL X1D7 100A --I 100A --I 100A K13 K13 K13 K13 HLC HLC HLC HLC 4N men 45 KVA -0b r 45 KVA -0N ( 45 KVA b 30 KVA 208Y/120 V 208Y/120 V 208Y/120 V 208Y/120 V SEE SHEET E5 FOR 1 -LINE PNL 3B3 100A M. BKR. 3PH, 4W HOUSE PNL 3D6 250A M. BKR. 3PH, 4W HOUSE PNL 3D3 100A M. BKR. 3PH, 4W HOUSE PNL 3E3-2 150 A M. BKR. 3PH, 5W COMPUTER IG SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION SD TB JMK 03.14.96 D INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 B ADDITIONAL CIRCUITS ADL2 LAB 17056700 ESBROOK 03.27.08 C REPLACE 400 HERTZ GENERATORS 32317 CASNE CEC 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE PNL 3B1 150 A M. BKR. 3PH, 5W COMPUTER IG DRAWN S DANG PNL 3E3-1 150 A M. BKR. 3PH, 5W COMPUTER IG PNL 3D6-1 100 A M. BKR. 3PH, 5W COMPUTER D LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE:TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 45KVA K-50 - TIERNEY AC345-8T18H11O-HLC-50-QT 30KVA K-13 - TIERNEY AC330-8718H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT I ST LT GF RACEWAY TYPE DESIGNATION INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION AUTOMATIC TRANSFER SWITCH - 480V, 4 -POLE GENERAL NOTES: MAIN CIRCUIT BREAKER WITH 120V SHUNT TRIP. FEEDER LENGTHS SHOWN ARE APPROXIMATE. ACTUAL FEEDER LENGTHS SHALL BE RECORDED AND UPDATED POST CONSTRUCTION FOR SHORT CIRCUIT AND ARC FLASH CALCULATIONS. REFERENCE DRAWINGS: 13 -YD -E505 C�\STUCTIO\ \OTES INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (GPU) PROVIDED BY BOEING. CONNECT TO PANEL 1D6 AS SHOWN. RE -CONNECT EXISTING CONDUIT AND CONDUCTORS. RACEWAY SCHEDUL REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 8 2010 City of Tukwila BUILDING DIVISION TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 ® 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #4/0 F6 250A 1 3" 3#250MCM 250MCM #2 100A 1 1-1/4" 3#2 #2 #6 #6 M5 Q3 150A 1 2" 3#1/0 #4 ® 250A 1 2-1/2" 3#250MCM #4 (-FLI-). 225A 1 2-1/2" 3#4/0 #4/0 #2 CLOSET324D5 DATA Ell8 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 075 8 RECEIVED C ° OF TUKWILA AUG 31 2018 L.:.P.'111 CENTER CASNE ENGINEERING, INC. (425) s»—inrn WWW Cd<NF COAI JOB NA ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 98 . ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, 205 KIRKLAND, WA 98033 522 1000 WWW.CASNE.COM NO. 181-085 DATE CHECKED T BENNETT SUBTITLE ONE LINE DIAGRAM — 60 HZ POWER CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S DANG CHECKED T BENNETT APPROVED J KOKOCZKA APPROVED K RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHEET IE4B JOB NO. COMP NO. DWG NO. 13-003-1E4B LAST SAVED: Au STEVEN GARRET( 3-03 INCREASE 400HZ POWER SYSTEM\_DRAWINGS\13-003-E4A \DESKTOP\181-085 C:\USERS\STEVEN.GAR J4 Q 150 AF 150 AT \ 1600 AF 1600 AT FROM SOUTH SUBSTATION FEEDER 93F3 0 1600A BREAKER LT ST GF \800 AF ) 800 AT ///// /1/ PNL 1D1 i50A MAIN 3PH. 4W PNL 1D6 -2 150A MAIN 3PH, 4W PNL 1D6- 800 A MAIN 3PH, 4W PANEL 1 D6 -- MAIN DISTRIBUTION SWITCHBOARD d BLDG. 13-03, COL. D/6 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PNL 1D5 150 A MAIN 3PH, 4W LIGHTING H LC 75 KVA. 208Y/120 V K13 PNL 1D1 - 100A M. BKR. 3PH, 4W HOUSE HOUSE PNL 105 100A M. BKR. 3PH, 4W HOUSE -I 100A HLC 0 45 KVA 208Y/120 V K13 p 100A HLC A 45 KVA H LC ' n 30 KVA 208Y/120 V 208Y/120 V COMPUTER IG COMPUTER IG K13 80A FREIGHT ELEVATOR CONTROLLER 40 HP PNL 1D5-2 100 A M. BKR. 3PH, 5W COMPUTER DATA CLOSET 129D5 100 AF 100 AT J 100A CONDENSOR 1C7A 30KW COMP. (3) 1 E P FAN 400Af 400AT CONDENSOR 1C7B 30KW COMP. (3) 1 HP FAN REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ISSUE FOR CONSTRUCTION SMD TB JMK 03,14.96 RECONCILED TO VAULT NO RM 03.27.18 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 400A 400A EIJPrO DRAWN S. DANG DATE REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC SEP 2 8 2016 City of .Tukwila BUILDING DIVISION sa B LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE: TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 30KVA K-13 - TIERNEY AC330-8T18H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT RACEWAY TYPE DESIGNATION 100A NON -FUSE DISCONNECT SWITCH. RATING AS NOTED. T ST LT GF INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION GENERAL NOTES: illi ► REFER TO DETAIL SHEET E521 FOR SHUNT TRIP FEEDER LENGTHS SHOWN ARE APPROXIMATE. ACTUAL FEEDER LENGTHS SHALL BE RECORDED AND UPDATED POST CONSTRUCTION FOR SHORT CIRCUIT AND ARC FLASH CALCULATIONS. REFERENCE DRAWINGS: 13 -YD -E4 CO\S I RUCTIO \OTES PROVIDE 250A BREAKER PLUG TO REDUCE BREAKER TRIP SETTING. MATCH EXISTING PLUG TYPE. INSTALL JBT JTP3 PLUS 180KVA 400HZ GROUND POWER UNIT (CPU) PROVIDED BY BOEING, CONNECT TO PANEL 1D6 AS SHOWN. PROVIDE CU CONDUCTORS, OVERHEAD CONDUIT AND SUPPORTS PER FEEDER SCHEDULE. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 (6-6) 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1 /4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 A4 1600A 4 41, 3#600MCM 600MCM #4/0 100A 1 1-1/4" 3#2 #2 #6 #6 5 Q3 150A 1 21, 3#1/0 #4 F6 250A 1 3" 3#250MCM 250MCM #2 0 50A 1 1" 3#8 #10 100A 1 1-1/2" 3#2 #6 0.. I• • II! 11 .1 �'1 1.. •.. C..F I ... ^•��.. 1.Y 4..,. Or I LIK '\ 1L ' (i) 250A 1 2-1/2" 3#250MCM min 1 t 9n4R #4 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 E ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB N0. 181-085 CASNE ENGINEERING, INC. CHECKED T.BENNLI 1 ENGINEER SUBTITLE ONE LINE DIAGRAM 60 HZ POWER SYSTEM CURRENT REVISION SYMBOL DATE 35379 13 08.10.18 CHECKED T.BENNETT APPROVED J.KOKOCZKA APPROVED K.RAMBALDINI TITLE 02.12.96 ELECTRICAL MASTER BUILDING 13-003 SHEET IE4A SEQUENCE NO. DWG NO. Dev. Center,Wa -03-1E4A 0 4 (A 1D1-2/38,40,42 JB UP TO 2C1-1/9,11,1 1 06-3/ 14a,16b,18b 6# 1 /0+ 1 /OG(SPIR L) 1 D1 -2/19a,21 b,23c 1D1-2/13a,15b,17c 1 D1-2/2a,4b,6c 1 D 1-2/8a,10b,12 20a,22b, 2C1-1/9,11 & 13,15 1D1-2/25a,27b,29c 1D1 -2/39b 13,15 400 HZ PANEL 1 D6-3 (1) 4"C 7#500KCMIL, #2/OGND JETPOWER I 400HZ GPU 180KVA 1/2"C 3#12 400HZ GPU#1 STATUS TO ANNUNCIATOR PANEL 1/2"C 3#12 SPARE TO ANNUNCIATOR PANEL it 8 16 24 ivy. SCALE: 1/8"=1'-0" 1 e ocis0 EFER= NCE DRAWINGS ► 13-003-2E160 LEGEND: REFER TO SHEET E1A FOR GENERAL SYMBOLS LEGEND HZ SYMBOL AMP VOLTAGE POLES WIRES MFG RECEPTACLE NEMA 400 =' 20 20 200Y/115 4 5 HUBBELL 3520 400 I3D 30 30 200Y/115 4 4 RUSS—STOLL FC3114W 400 OD 60 60 200Y/115 4 4 RUSS—STOLL FC3124W-78 400 IV 15 15 115 2 3 HUBBELL 7487 DC FO 20 20 28 2 3 HUBBELL 6810 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 +1 28 VDC PANEL. 400 HZ PANEL. GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. ALL CONDUITS AND FITTINGS FOR 400 HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS: ALL 400HZ AND DC CONDUCTORS TO BE #10 AWG, STRANDED COPPER, INSULATION TYPE THHN/ THWN, UNLESS OTHERWISE NOTED. ALL 400HZ HOME RUNS SHALL BE INDIVIDUALLY INSTALLED FROM PANEL TO RECEPTACLE LOCATION. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1, b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 400HZ A 0 (LEFT BUS IN PNL) B 0CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND 28V DC POSITIVE (+) NEGATIVE (—) EQUIPMENT GROUND 200Y/115V BLACK RED BLUE WHITE GREEN RED BLACK GREEN 575Y/330V BROWN ORANGE YELLOW GRAY GREEN 4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. 6. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL—WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. 8. LABEL ALL CONDUITS FOR 400 HZ AND 28 VDC SYSTEMS AT ALL INTERFACES WITH JUNCTION BOXES, ENCLOSURES AND EQUIPMENT. REFER TO SPECIFICATIONS. D v 0 0\ =S PULL BACK EXISTING CONDUCTORS AND CONDUIT FROM PANEL 106-3 FOR GROUND POWER SYSTEM #1. RETAIN CONDUCTORS AND CONDUIT FOR RE—USE AND RE—CONNECTION THROUGH NEW MAIN CIRCUIT BREAKER IN PANEL 106-3. REVIEWED FOR COMPLIANCE ITH NFPA 7 SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVED Cm, a e, SDP TUKWILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWWCASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUED FOR CONSTRUCTION 0 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 B RELOCATE OUTLETS C REPLACE 400 HERTZ GENERATORS J#771978—LO 32317 K. DARCY 6/02/97 RECORD DRAWING 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 — RECONCILED TO VAULT NO RM 03.27.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN T. BENNLII DATE CHECKED S. DANG SUBTITLE 400 HZ & 28V DC POWER PLAN CURRENT REVISION 35379 SYMBOL D DATE 08.10.18 ENGINEER T. BENNETT CHECKED S. DANG APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI TITLE 02.12.96 ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. A—H/1-7 Dev. Center,Wa SHEET IEI6OR JOB NO. MFC -95060 COMP NO. DWG NO. 13-003-1E160R 45 (,T, [T J45 00/NF 100/NF IN SLAB 1D6-1/2,4,6 IN SLAB 1D6-1/8,10,12 4 IN SLAB 1 D6/1,3,5 0 1D5 f� r J4> 1D6-1/7,9,11 03) 1 MCC 1D5 �1D6-1/13,15,17 X1 D7/1,3,5 1D6,-1/14,16,18 1 1D6-3 1D6/19,21,23 1D6/20,22 2 400- 1E2 E535 CONVERTOR 400A DISCONNECT &(2)4" SPARE \\ TO SOUTH SUB 93F3 HANDHOLE TO SITE EMERG. PANEL—X IN SOUTH SUBSTATION 4"C -4#4/O & 2G (3)4"C—SPARE -0) 16' SCALE: 8"= REVIEWED'. COMPLI O �� IFPA SEP 28 2010 Dtty a UKWlla BUILDING MI ON� LEGEND: REFER TO SHEET El FOR GENERAL SYMBOLS LEGEND RACEWAY TYPE DESIGNATION — REFER TO SINGLE LINE DIAGRAM E4 FOR RACEWAY SCHEDULES Vii1/A 480Y/277 V, 3—PHASE, 4—WIRE PANELBOARD DISCONNECT SWITCH — RATING AS SHOWN SWITCH RATING/FUSE RATING (NF=NON—FUSED) El 45 DRY TYPE TRANSFORMER — SIZE AS NOTED 60 NF `Tl 45 CEILING MOUNTED DRY TYPE TRANSFORMER — SIZE AS NOTED GENERAL NOTES: 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, LESS THAN 2". FOR SIZES 2" AND ABOVE AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID CONDUIT. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. 3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY INSULATED GROUND CONDUCTORS PER NEC 250-57(b) EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS FOLLOWS: 208Y/120V 480Y/277V A 0 (LEFT BUS IN PNL) BLACK BROWN B (CENTER BUS IN PNL) RED ORANGE C (RIGHT BUS IN PNL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL* GRN/YEL* *GREEN WITH YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS d'O 1 II S DEN 0 LITI 0 \ OT REMOVE cs REMOVE 400A DISCONNECT SWITCH. REMOVE ABANDONED RECEPTACLE HOUSING. REMOVE CONDUIT AND CONDUCTORS FOR 400A SWITCH AND RECEPTACLE HOUSING, BACK TO SOURCE PANEL 106. RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 0 80A 1 1-1/2" 3#4 #6 (C16) 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 M4 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 F6 250A 1 3" 3#250MCM 250MCM #2 (1\-t15 100A 1 1-1/4" 3#2 #2 #6 #6 50A 1 1" 3#8 #10 E4 600A 2 3,x 3#350MCM #2/0 #1/0 ® 500A 2 2-1/2" 3#250MCM Q3 150A 1 2" 3#1/0 #4 F4 225A 1 2-1/2" 3#4/0 #4/0 #2 (A4) 1600A 4 4,x 3#600MCM 60C 1 Frll rp� e oN 1n A � V '�0 SLI S-0' ISSUE FOR CONSTRUCTION AUGUST 10, 2018 AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNECOM JOB NO. 181-085 REVISION BY APPROVED DATE Y REVISION BY APPROVED DATE ISSUED FOR CONSTRUCTION 03.14.96 REPLACE 400HZ GENERATORS 32317 D. OTTEN DLO 01.16.17 INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN S. DANG CHECKED T. BENNE( I DATE SUBTITLE 480 VOLT MAIN POWER PLAN CURRENT REVISION 35379 SYMBOL c DATE 08.10.18 ENGINEET2 S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 COL. XA—H/1-7 DEV. CENTER, WA SHEET IE2R JOB NO. MFC -95060 COMP NO. DWG NO. 13-03-1E2R r 480V FEEDER FROM MAIN DISTRIBUTION SWITCHBOARD 1D6. REF. SHT E4B FOR DETAILS LENGTH 55' 250AT 400 HZ GROUND POWER SYSTEM NO. 1 180 KVA/144 KW 200/115V, 400 HZ 3 PH, W OUTPUT o 3#12 STATUS AND FAULT ALARMS TO ANNUNCIATOR PANEL IN AIL LAB. SEE 2E160 FOR PANEL LOCATION AND E524 FOR PANEL DETAILS (TYPICAL ALL BREAKERS) 5 } LINE DROP COMPENSATOR 6% TAP // // /// // / / // 4/ /,/ // 400 AF 400 AF 411 AF / AF 75 AT / 175 AT / 175 AT / 175 AF � AT / 175� AT 45 . KVA 45 KVA 45 KVA 45 KVA 45 KVA SPARE U8 11> (TYP) Est. 120' Est. 125' 8 PNL 1D1-2 200Y/115V 200A MBKR 400 HZ PNL 2D1 200Y/115V 200A MBKR 400 HZ Est. 145' 8 6 j PNL 2A4-3 200Y/115v 200A MBKR 400 HZ Est. 75' 8 PNL 2D4-1 200Y/115V 200A MBKR 400 HZ r T8 PANEL 1D6-3 - MAIN 400 HZ POWER DISTRIBUTION SWITCHBOARD WITH LDC 400 AF 300 AT 4 400 AF 300 AT 5 LINE DROP COMPENSATOR 6% TAP 200/115 VOLT, 3000 A, 400 HZ, 3 PH, 4 WIRE (6,000 AIC AT 400 HZ) 4 400 AF 300 AT 4 400 AF 300 AT 1 i 400 AF 300 AT 75 KVA 75 KVA 75 KVA 75 KVA 75 KVA SPACE FOR FUTURE BRKS. 400 AF (2 MIN) Est. 125' 8 Est. 125' CJ Est. 125' 8 O Est. 125' UNDER FLOOR J—BOX TYP. OF 4 SEE 2E160 POWER DISTRIBUTION UNIT PDU #1 POWER DISTRIBUTION UNIT PDU #2 L J AVIONICS INTERGRATION LAB LAB #1 • W8 0 Est. 140'-155" FEEDERS PARALLELED IN JUNCTION BOX 200/200 200 NATO AVIONICS INTERGRATION LAB 2nd Floor © Col. B2 200/200 200 4 4> 4 > 3 ELI8-07$ M LEGE\D G BREAKER WITH 120V SHUNT TRIP \PAL \OTES 6i ALL CONDUITS AND FITTINGS FOR 400 HERTZ CABLING TO BE ALUMINUM AND SHALL BE ARRANGED WITH MAXIMUM PHYSICAL SEPARATION FROM COMMUNICATION RACEWAYS AND OTHER CABLES. 400HZ GEN AND DISTRIBUTION SWITCHBOARD INPUT/ OUTPUT CIRCUIT BREAKERS TO BE SPECIALLY MANUFACTURED WITH CALIBRATION FOR 400 HZ SYSTEM APPLICATION. ALL 400 HZ FEEDERS TO HAVE 90°C, TYPE XHHW-2 INSULATION UNLESS OTHERWISE NOTED. 400 HZ FEEDERS TO BE IN A SPIRAL WOUND CONFIGURATION. REFER TO DETAIL 3, SHEET E508. INSTALLED IN 400HZ DISTRIBUTION SWITCHBOARD. FRONT ACCESS. 120V SHUNT TRIP MAIN BREAKER BREAKER EQUIPTED WITH N.O. AND N.C. AUX CONTACTS. 8 > FEEDER LENGTHS SHOWN ARE APPROXIMATE. -VOLITIO\ \OTES PULL BACK EXISTING CONDUCTORS AND CONDUIT FROM PANEL 1D6-3 FOR GROUND POWER SYSTEM #1. RETAIN CONDUCTORS AND CONDUIT FOR RE—USE AND RE—CONNECTION THROUGH NEW MAIN CIRCUIT BREAKER IN PANEL 1D6-3. REVIEWED FOR COMPLIANCE WITH NFPA 70 o NEC SEP 2 8 2018 City of •Tukwila BUIL h IR (VISION FEEDER SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG ® 250 A 1 2-1/2" 3-250 MCM #4 F4 600A 1 4" 6-500 MCM #500MCM #2/0 T8 200 A 1 2-1/2" 6 #1/0 #1/0 #3 c:1-8) 175 A 1 2" 6 #2 #2 #4 ® 300A 2 2 1/2" 3— #4/0 #4/0 #3 W8 200 A 1 2 1/2" 3— 4/0 4/0 aEG NE: „ i C TY OF TUKWILA AUG 31 2018 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 PERMIT CENTER ER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA (425) 522-1000 wwwrn cuF rnu JOB NO. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th SUITE 205 KIRKLAND, WA 9803.3 WWW. CASNE. COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED A B C ISSUED FOR CONSTUCTION DCN 29 - REVISE PER MANUF. DESIGN NATO AWACS INTEGRATION LAB SMB TB JMK 03.14.96 RECONCILED TO VAULT SD TB JK KR 8.23.96 E INCREASE 400HZ POWER SYSTEM 35379 NO CASNE RM SHG DATE 03.27.18 08.10.18 J#170097 DEH JV/AW 7.8.98 D REPLACE 400 HERTZ GENERATORS 32317 RECORD DRAWING 32317 CASNE CASNE CEC SHG 02.01.17 06.26.17 ?3, ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNETT SUBTITLE ONE LINE DIAGRAM 400 HZ POWER SYSTEM CURRENT REVISION SYMBOL 35379 DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNETT APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.95 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-03 Dev. Center,Wa SHEET E4ER JOB NO. MFC -95060 COMP NO. DWG NO. 13-03—E4ER 0 3 N 0) 0 w U) CD 3-003-E4AR - S 3-03 INCREASE 400HZ POWER SYSTEM\_DRAWINGS\ C:\USERS\STEVEN.GARRETT\DESKTOP\181-085 BOE LT ST GF 150 AF 150 AT PNL 1D1 150A MAIN 3PH, 4W LT ST GF \ 1600 AF / 1600 AT FROM SOUTH SUBSTATION FEEDER 93F3 1600A BREAKER LT ST GF 800 AF 800 AT PNL 1D6-1 800 A MAIN 3PH. 4W PANEL 1D6 - MAIN DISTRIBUTION SWITCHBOARD @ BLDG. 13-03, COL. D/6 480 V, 1600 A, 3 PH, 4 WIRE - 42,000 AIC (AVAILABLE S.C.A. = 41,560 A) PNL 1D6-2 150A MAIN 3PH, 4W PNL 1D5 150 A MAIN 3PH, 4W LIGHTING HLC 75 KVA �'lm 208Y/120 V K13 HOUSE HOUSE HOUSE • • -I 100A -I 100A HLC HLC HLC . ri 45 KVA -0.. r -,- 45 KVA LUJJ 4IP n -✓Y` y) 30 KVA 208Y/120 V 208Y/120 V K13 COMPUTER IG COMPUTER IG 208Y/120 V K13 PNL 1D5-2 100 A M. BKR. 3PH, 5W COMPUTER 80A FREIGHT ELEVATOR CONTROLLER 40 HP DATA CLOSET 129D5 LT ST GF l 100 AF / 100 AT 0 100A CONDENSOR 1 C7A 30KW COMP. (3) 1 HP FAN LT ST GF 100 AF 100 AT ---I J 100A CONDENSOR 1C7B 30KW COMP. (3) 1 HP FAN T LT GF 400AF 400AT RACEWAY SCHEDULE TYPE RATING CONDUIT CONDUCTORS PER CONDUIT QTY SIZE PHASE NEUTRAL GND IG J4 150A 1 2" 3#1/0 #1/0 #4 m 80A 1 1-1/2" 3#4 #6 Q6 150A 1 2-1/2" 3#1/0 #2/0 #4 #4 4714) 100A 1 1-1/4" 3#2 #2 #6 D4 800 A 2 4" 3#600MCM #600MCM #2/0 A4 1600A 4 4" 3#600MCM 600MCM #4/0 100A 1 1-1/4" 3#2 #2 #6 #6 M Q3 150A 1 2" 3#1/0 #4 F6 250A 1 3" 3#250MCM 250MCM #2 W3 50A 1 1" 3#8 #10 0 100A 1 1-1/2" 3#2 #6 T4 400A 1 4" 3 #500MCM LEGEND: HLC HARMONIC LOAD COMPENSATED TRANSFORMER. NOTE: TRANSFORMERS ALL ARE TIERNEY "QUIETRAN" K -RATED UNITS 45KVA K-13 - TIERNEY AC345-8T18H-HLC-13-QT 30KVA K-13 - TIERNEY AC330-8T18H-HLC-13-QT 75KVA K-13 - TIERNEY AC375-8T18H-HLC-13-QT RACEWAY TYPE DESIGNATION -1100A NON -FUSE DISCONNECT SWITCH. RATING AS NOTED. ST LT GF INSTANTANEOUS OVERCURRENT PROTECTION FUNCTION SHORT TIME OVERCURRENT PROTECTION FUNCTION LONG TIME OVERCURRENT PROTECTION FUNCTION GROUND FAULT OVERCURRENT PROTECTION FUNCTION GENERAL NOTES: REFER TO DETAIL 1, SHEET E521 FOR SHUNT TRIP DIAGRAM. REFERENCE DRAWINGS: 13 -YD -E4 REMOVAL NOTES: REMOVE ABANDONED CONDUCTORS TO 400A DISCONNECT ON SOUTHEAST END OF 13-003. REMOVE 400A TRIP PLUG. PREPARE BREAKER FOR RE -USE WITH NEW 400HZ GPU. REMOVE 400A DISCONNECT ALONG WITH ABANDONED RECEPTACLE ENCLOSURE. EL1 8-07 5 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED .FOR WITHCOMPLIANCE NEPA7O - NEC SEP 2 8 2018 City of Tukwila BUILDING DIVISION RECEIVE:0 CITY OF TUKWILA AUG 31 2018 PERMIT CENTER E CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGYCONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 980, (425) 522-1000 WIVW!`d CNF SNA JOB NA ELECTRICAL AND CONSULTANTS NE 38th 205 KIRKLAND, WA 98033 WWW. CASNE COM NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION SMD TB JMK 03.14.96 RECONCILED TO VAULT NO RM 03.27.18 B INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN S. DANG DATE APPROVED BY DEPT. DATE CHECKED T.BENNETT ENGINEER SUBTITLE ONE LINE DIAGRAM 60 HZ POWER SYSTEM CURRENT REVISION SYMBOL D DATE 35379 B 08.10.18 CHECKED T.BENNETT APPROVED J.KOKOCZKA APPROVED K.RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER BUILDING 13-003 Dev. Center,Wa SHEET 1 E4AR SEQUENCE NO. DWG NO. 13-03-1E4AR G \.RAL \OT is A. WORK INCLUDED: FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS FOR COMPLETION OF ALL ELECTRICAL SYSTEMS AND RELATED WORK AS INDICATED ON THE DRAWINGS. THE WORK TO BE PERFORMED INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING SYSTEMS: 480Y/277V POWER, 208Y/120V POWER, 200/115V 400HZ, LIGHTING, GROUNDING, FIRE ALARM, DATA AND OTHER WORK AS SHOWN ON THE DRAWINGS. B. CODES AND ORDINANCES: ALL WORK SHALL COMPLY WITH LOCAL CODES AND ORDINANCES INCLUDING THE NATIONAL ELECTRICAL CODE (NEC). C. DEMOLITION: 1. UNLESS OTHERWISE INDICATED, THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL MATERIAL, EQUIPMENT, WIRING DEVICES, LIGHTING FIXTURES, CABLES, AND WIRING, INCLUDING THOSE ITEMS ASSOCIATED WITH THE TELEPHONE, DATA, PAGING AND FIRE ALARM SYSTEMS. 2. ALL UNUSED CONDUIT AND WIRING SHALL BE COMPLETELY STRIPPED AND REMOVED BACK TO THE SOURCE OR CLOSEST ACTIVE JUNCTION BOX, SCHEDULED TO REMAIN, EXCEPT WHEN LOCATED IN AN EXISTING FLOOR SLAB NOT SCHEDULED FOR DEMOLITION. UNUSED CONDUITS IN FLOOR SLAB SHALL BE CUT OFF AND PLUGGED FLUSH WITH SLAB SURFACE UNLESS OTHERWISE NOTED. 3. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BOEING REPRESENTATIVE FOR DIRECTIONS ON THE DISPOSAL, SALVAGE, RELOCATION ETC., OF ALL REMOVED ITEMS LISTED IN NOTE 1, ABOVE. 4. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE -ENERGIZING ANY POWER SERVICE REQUIRED FOR THIS DEMOLITION WORK TO ENSURE SAFE WORKING CONDITIONS. 5. THE ELECTRICAL CONTRACTOR SHALL COORDINATE AND SCHEDULE WITH THE BOEING REPRESENTATIVE ANY POWER, TELEPHONE, DATA, CMCS, PLANT PAGING, FIRE ALARM AND ADT CONTROL SHUT DOWNS REQUIRED BY THIS DEMOLITION WORK AND ALSO ENSURE THAT ADEQUATE TEMPORARY AND/OR REROUTING OF SERVICES ARE APPROVED TO AREAS NOT PART OF THIS DEMOLITION WORK, BUT WHICH ARE ADJACENT TO THE AREA(S) OF WORK WHICH WOULD BE AFFECTED BY A SHUT DOWN. THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE BOEING STANDARD LOCKOUT/TAGOUT PROCEDURES THROUGHOUT ANY REQUIRED SHUT DOWN, DEMOLITION AND/OR TEMPORARY RECONNECTION PROCESS. 6. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE BOEING REPRESENTATIVE THE MAINTENANCE AND REROUTING OF ALL EXISTING POWER, LIGHTING, TELE/DATA, FIRE ALARM, ADT AND PLANT PAGING SYSTEMS CIRCUITS THAT PASS THROUGH THE DEMOLITION AREA BUT ARE NOT INDICATED FOR REMOVAL, AS FIELD REQUIRED. 7. THE ELECTRICAL CONTRACTOR SHALL OBTAIN FROM AND COORDINATE WITH THE BOEING REPRESENTATIVE THE PROVISIONS AND REQUIREMENTS OF TEMPORARY POWER SERVICE FOR THE DEMOLITION WORK. 8. REMOVAL AND DISPOSAL OF ALL IDENTIFIED HAZARDOUS MATERIALS SHALL BE PERFORMED UNDER THE REQUIREMENTS OF BOEING SHEA, OSHA, EPA AND ANY OTHER AUTHORITY HAVING JURISDICTION IN APPLICABLE STATE, CITY AND LOCAL CODES D. RECORD DRAWINGS: MAINTAIN "AS -BUILT DRAWINGS ON SITE, UP TO DATE AT ALL TIMES. THESE DRAWINGS SHALL CLEARLY INDICATE, IN RED PENCIL ON COPIES OF CONTRACT DRAWINGS, THE LOCATIONS OF ALL CONCEALED AND UNDERGROUND CONDUIT, AND ALL DEVIATIONS TO THE DRAWINGS. E. PANEL SCHEDULES: MAINTAIN PANEL SCHEDULES WITH ACCURATE CIRCUIT BREAKER, WIRE, AND LOAD INFORMATION ON ALL ELECTRICAL PANELS INSTALLED OR REVISED UNDER THIS CONTRACT. F. MATERIALS AND EQUIPMENT: EXCEPT AS OTHERWISE INDICATED, ALL MATERIALS AND EQUIPMENT SHALL BE NEW, FREE OF DEFECTS, AND SHALL BE UL APPROVED AND LABELED. 1. RIGID METAL CONDUIT: HOT -DIP GALVANIZED, THREADED; FITTINGS AND CONDUIT BODIES TO BE THREADED TYPE, GALVANIZED, MATERIAL TO MATCH CONDUIT. 2. RIGID ALUMINUM CONDUIT: NON-MAGNETIC ALUMINUM ALLOY, THREADED; FITTINGS AND CONDUIT BODIES TO BE THREADED TYPE, MATERIAL TO MATCH CONDUIT. 3. ELECTRICAL METALLIC TUBING (EMT): STEEL TUBING, HOT -DIP GALVANIZED; FITTINGS TO BE GALVANIZED STEEL, RAIN TIGHT, INSULATED THROAT, COMPRESSION TYPE. 4. FLEXIBLE METAL CONDUIT: LIQUIDTIGHT WITH COPPER BONDING TAPE AND PVC WEATHERPROOF JACKET. 5. POLY -VINYL CHLORIDE (PVC) CONDUIT: SCHEDULE 40 OR THICKER, UL LISTED FOR DIRECT BURIAL USE. 6. OUTLET BOXES: GALVANIZED STEEL, 4" SQUARE; BOXES LARGER THAN 12 INCHES IN ANY DIMENSION TO BE HINGED ENCLOSURE, NEMA 12 OR AS OTHERWISE NOTED. 7. BUILDING WIRE: INTERIOR FEEDERS AND BRANCH CIRCUITS TO BE COPPER, STRANDED CONDUCTOR, 600V INSULATION, 90 DEGREE TYPE THHN/THWN; EXTERIOR FEEDERS AND BRANCH CIRCUITS TO BE COPPER, STRANDED CONDUCTOR, 600V INSULATION, TYPE XHHW. 8. WIRING DEVICES: SPECIFICATION GRADE AND UL LISTED, DEVICE PLATES AND DEVICE COLOR TO MATCH EXISTING IN IMMEDIATE AREA OF NEW WORK. IN GENERAL, FACTORY AREAS WILL HAVE BROWN COLORED DEVICES AND GALVANIZED STEEL DEVICE PLATES; OFFICE AREAS WILL HAVE DEVICES AND DECORATIVE DEVICE PLATES AS SPECIFIED BY THE ARCHITECT. 9. CIRCUIT BREAKERS IN EXISTING PANELBOARDS: THE SAME MANUFACTURER AND FRAME TYPE AS THOSE REQUIRED FOR THE EXISTING PANELBOARDS. RATINGS AND FRAME TYPES SHALL BE AS INDICATED ON DRAWING OR IN PANEL SCHEDULES. 10. CONDUIT AND EQUIPMENT SUPPORTS: CONDUIT CLAMPS, STRAPS, AND SUPPORTS TO BE GALVANIZED STEEL; SUPPORT CHANNEL TO BE ELECTRO -GALVANIZED, 12 GAUGE, 1-5/8"X1-5/8" MINIMUM SIZE. SUPPORT SYSTEMS SHALL BE ADEQUATE FOR WEIGHT OF EQUIPMENT AND CONDUIT, INCLUDING WIRING, WHICH THEY CARRY; AND SHALL CONFORM TO SEISMIC REQUIREMENTS OF INTERNATIONAL BUILDING CODE (IBC) 2015. 11. CIRCUIT IDENTIFICATION: NAMEPLATES TO BE ENGRAVED METAL OR PHENOLIC WITH 1/" WHITE LETTERS ON BLACK BACKGROUND; LABELS TO BE EMBOSSED ADHESIVE TAPE, 3/8" WHITE LETTERS ON BLACK BACKGROUND; WIRE AND CABLE MARKERS TO BE CLOTH MARKERS, SPLIT SLEEVE OR TUBING TYPE. G. CONDUITS: 1. USE 3/4" EMT UNLESS OTHER NOTED OR AS SHOWN ON THE DRAWINGS. 2. USE RIGID GALVANIZED STEEL FOR ALL EXPOSED CONDUIT RUNS ABOVE GROUND, IN CHASES, SUBJECT TO PHYSICAL DAMAGE OR SUBJECT TO MOISTURE. 3. USE RIGID ALUMINUM FOR ALL 400HZ CONDUIT RUNS. 4. USE PVC CONDUIT LISTED FOR DIRECT BURIAL UNDERGROUND, IN CONCRETE OR IN DUCT BANKS. ALL RISERS SHALL USE PVC COATED STEEL ELBOWS COUPLED TO PVC CONDUIT WITH LISTED ADAPTERS. 5. HEADROOM SHALL BE REQUIRED TO BE 7'0" MINIMUM UNLESS OTHERWISE SHOWN ON DRAWINGS OR APPROVED BY OWNER. 6. ROUTE EXPOSED CONDUIT PARALLEL AND PERPENDICULAR TO WALLS AND ADJACENT PIPING. 7. MAINTAIN MINIMUM 6" CLEARANCE BETWEEN CONDUIT AND PIPING. MAINTAIN MINIMUM 12" CLEARANCE BETWEEN CONDUIT AND HEAT SOURCES SUCH AS FLUES, STEAM PIPES, AND HEATING APPLIANCES. 8. DO NOT FASTEN CONDUIT WITH WIRE OR PERFORATED PIPE STRAPS. REMOVE ALL WIRE USED FOR TEMPORARY CONDUIT SUPPORT DURING CONSTRUCTION, BEFORE CONDUCTORS ARE PULLED. 9. CONDUIT TERMINATIONS AT SWITCHBOARDS, PULL BOXES, ETC., SHALL BE RIGIDLY SECURED USING LOCKNUTS AND METALLIC GROUNDING INSULATING BUSHINGS WHERE REQUIRED OR AS INDICATED ON DRAWINGS. 10. USE CONDUIT BODIES TO MAKE SHARP CHANGES IN DIRECTION, AS AROUND BEAMS, ON APPROVAL OF ENGINEER ONLY. 11. WHERE CONDUITS ENTER/EXIT FLOOR, PROVIDE THREADED COUPLING WITH UPPER END FLUSH WITH FINISHED FLOOR. INSTALL THREADED PLUGS IN UNUSED CONDUITS. 12. SEAL RACEWAY PENETRATION WHERE RACEWAY PASSES THROUGH EXTERIOR WALL, FLOOR OR RATED FIREWALL WITH MATERIAL COMPATIBLE WITH THE BUILDING MATERIAL THROUGH WHICH THE RACEWAY PASSES. ALL SEALING COMPOUNDS MUST BE UL LISTED FOR THE APPLICATION. H. COORDINATION OF BOX LOCATIONS: 1. PROVIDE ELECTRICAL BOXES AS SHOWN ON THE DRAWINGS, AND AS REQUIRED FOR SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS AND CODE COMPLIANCE. 2. SUPPORT BOXES INDEPENDENT OF CONDUIT. 3. ELECTRICAL BOX LOCATIONS SHOWN ON THE DRAWINGS ARE APPROXIMATE UNLESS DIMENSIONED. 4. LOCATE AND INSTALL BOXES TO ALLOW ACCESS. WHERE INSTALLATION IS INACCESSIBLE, COORDINATE LOCATIONS AND SIZES OF REQUIRED ACCESS DOORS. 5. LOCATE AND INSTALL TO MAINTAIN HEADROOM AND TO PRESENT A NEAT APPEARANCE. HEADROOM SHALL BE REQUIRED TO BE 7'-O" MINIMUM UNLESS OTHERWISE SHOWN ON DRAWINGS OR APPROVED BY OWNER. REVISION BY APPROVED DATE SYM REVISION G \HA OT is CO\TI\ D I. SUPPORTING DEVICES: 1. FASTEN HANGER RODS, CONDUIT CLAMPS, AND OUTLET AND JUNCTION BOXES TO BUILDING STRUCTURE USING BEAM CLAMPS. 2. USE SELF -DRILLING ANCHORS OR EXPANSION ANCHORS ON CONCRETE SURFACES; SHEET METAL SCREWS IN SHEET METAL STUDS. 3. DO NOT FASTEN SUPPORTS TO PIPING, DUCTWORK, MECHANICAL EQUIPMENT OR CONDUIT. 4. FABRICATE SUPPORTS FROM STRUCTURAL STEEL OR STEEL CHANNEL, RIGIDLY WELDED OR BOLTED TO PRESENT A NEAT APPEARANCE. USE HEXAGON HEAD BOLTS WITH SPRING LOCK WASHERS UNDER ALL NUTS. COLD GALVANIZE ENDS OF CUT CHANNEL IN EXTERIOR AND/OR DAMP LOCATIONS. 5. IN WET LOCATIONS, INSTALL FREE STANDING ELECTRICAL ENCLOSURES ON HOUSEKEEPING PADS, 3" MINIMUM HIGH. 6. INSTALL SURFACE MOUNTED CABINETS, ENCLOSURES, AND PANELS WITH A MINIMUM OF FOUR ANCHORS. PROVIDE STEEL CHANNEL SUPPORTS AND PROVIDE A MINIMUM OF 1" GAP BETWEEN WALL AND EQUIPMENT. J. DEVICE MOUNTING HEIGHT AND ORIENTATION: 1. FACTORY AREAS: MOUNT DEVICES AT 48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. IF IMMEDIATE AREA HAS DEVICES MOUNTED BELOW 48", CONTACT OWNER FOR RESOLUTION OF MOUNTING HEIGHT. 2. SWITCHES SHALL BE MOUNTED WITH OFF POSITION DOWN. K. GENERAL WIRING METHODS: 1. USE WIRE NO SMALLER THAN 12 AWG FOR POWER AND LIGHTING CIRCUITS, AND NO SMALLER THAN 14 AWG FOR CONTROL WIRING, UNLESS OTHERWISE NOTED ON THE DRAWINGS. 2. FOR 400HZ SYSTEMS USE WIRE NO SMALLER THAN #10 AWG. WIND CONDUCTORS IN A SPIRAL CONFIGURATION TO EQUALIZE PHASE IMPEDANCES AND MINIMIZE VOLTAGE DROP. 3. SPLICE ONLY IN JUNCTION OR OUTLET BOXES. NO SPLICING SHALL BE PERMITTED IN PANELBOARD ENCLOSURES WITHOUT SPECIFIC APPROVAL FROM OWNER. 4. FEEDERS SHALL NOT BE SPLICED WITHOUT SPECIFIC APPROVAL FROM OWNER. 5. NEATLY TRAIN AND LACE WIRING INSIDE BOXES, EQUIPMENT, AND PANELBOARDS. L. WIRING CONNECTIONS AND TERMINATIONS: 1. SPLICE ONLY IN ACCESSIBLE JUNCTION BOXES. 2. THOROUGHLY CLEAN WIRES BEFORE INSTALLING LUGS AND CONNECTORS. 3. MAKE SPLICES, TAPS AND TERMINATIONS TO CARRY FULL AMPACITY OF CONDUCTORS WITHOUT PERCEPTIBLE TEMPERATURE RISE. 4. TERMINATE DEAD -ENDED CONDUCTORS WITH ELECTRICAL TAPE AND MAKE SAFE. A. GROUNDING: 1. UNDERGROUND GROUND GRID CONDUCTORS SHALL BE #4/0 BARE COPPER STRANDED UNLESS OTHERWISE NOTED. 2. FENCE POST AND FENCE GROUNDING WIRES SHALL BE #2 BARE COPPER STRANDED UNLESS OTHERWISE NOTED. 3. ALL GROUND GRID WIRES SHALL BE BURIED A MINIMUM OF 12" BELOW FINISHED GRADE. 4. ALL CABLE TO CABLE GROUND CONNECTIONS SHALL BE EXOTHERMIC WELDED. 5. ALL CABLE TO EQUIPMENT OR GROUND BUS CONNECTIONS SHALL BE MADE WITH COMPRESSION TERMINAL LUGS. 6. ALL FENCE POSTS SHALL BE GROUNDED TO YARD GROUND GRID USING MECHANICAL CLAMPS. 7. ALL FENCE GATES SHALL BE GROUNDED WITH FLEXIBLE COPPER BRAID. M. COLOR CODING: 1. INSULATION ON CONDUCTOR SIZES #6 AWG AND SMALLER SHALL BE COLORED. CONDUCTOR SIZES #4 AWG AND LARGER MAY HAVE BLACK INSULATION WITH PLASTIC TAPE OF THE APPROPRIATE COLOR FROM THE TABLE BELOW. DESCRIPTION 120/208V 277/480V PHASE A (LEFT) BLACK BROWN PHASE B (CENTER) RED ORANGE PHASE C (RIGHT) BLUE YELLOW NEUTRAL WHITE WHITE GROUND GREEN GREEN ALTERNATIVELY FOR 400HZ SYSTEMS, USE THE APPROPRIATE COLOR FROM THE TABLE BELOW. 400HZ DESCRIPTION PHASE A (LEFT) PHASE B (CENTER) PHASE C (RIGHT) NEUTRAL GROUND 115/200V BLACK RED BLUE WHITE GREEN 330/575V BROWN ORANGE YELLOW WHITE GREEN FOR 28VDC SYSTEMS, USE THE FOLLOWING TABLE 28VDC POSITIVE (+) NEGATIVE (-) GROUND RED BLACK GREEN N. CIRCUIT IDENTIFICATION: 1. USE EMBOSSED TAPE FOR INTERIOR 120V RECEPTACLES, 120V & 277V SWITCHES, BOXES AND DEVICES, AND JUNCTION BOXES. 2. INSTALL ENGRAVED NAMEPLATES ON ALL 480V RECEPTACLES, EQUIPMENT DISCONNECTS, CONTROL PANELS, ETC., AND ALL EXTERIOR EQUIPMENT AND DEVICES, INSTALLED OR REVISED UNDER THIS CONTRACT. THIS INCLUDES THOSE NOT PHYSICALLY RELOCATED BUT RECIRCUITED. 3. SECURE NAMEPLATES TO EQUIPMENT USING SCREWS OR WIRE LOOP. ADHESIVES ARE NOT ACCEPTABLE. 4. NAMEPLATES AND LABELS SHALL INDICATED PANEL AND CIRCUIT NUMBER EQUIPMENT IS SERVED FROM. (E.G. - "206A5E/2A FOR CIRCUIT 2A FROM PANEL 206A5E) 5. PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARD GUTTERS, PULL BOXES, OUTLET AND JUNCTION BOXES, AND AT ALL LOAD CONNECTIONS. IDENTIFY WITH BRANCH CIRCUIT OR FEEDER NUMBER AS INDICATED ON DRAWINGS. FOR CONTROL WIRING, IDENTIFY WITH WIRE NUMBER INDICATED ON THE SCHEMATIC OR INTERCONNECTION DIAGRAMS. 0. EMERGENCY POWER IDENTIFICATION: 1. IDENTIFY ALL BOXES, ENCLOSURES, PANELS, ETC. WHICH CONTAIN EMERGENCY POWER CIRCUITS AND ARE INSTALLED OR WORKED IN WITH APPROPRIATE "EMERGENCY SYSTEM" LABELS AS REQUIRED BY THE WAC. 2. EMERGENCY POWER WIRING SHALL BE INDEPENDENT OF OTHER WIRING AND EQUIPMENT EXCEPT AS PERMITTED BY NEC. BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 i"Th ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE SCG SST_ D WOR< FLOW THE FOLLOWING IS A SUGGESTED ORDER OF OPERATIONS TO COMPLETE THE WORK OUTLINED IN THIS DRAWING SET. THIS LIST IS NOT COMPREHENSIVE; THE CONTRACTOR SHALL REFER TO THE ATTACHED DRAWINGS FOR FURTHER DETAIL ON WORK TO BE PERFORMED. ALL WORK SHALL BE COORDINATED WITH BOEING. 1. RE -PLACE JBT JETPOWER III GROUND POWER UNIT (GPU) #1 SUPPLIED BY BOEING. SECURE USING NEW ANCHORAGE. 2. PLACE NEW JBT JETPOWER III GROUND POWER UNIT (GPU) SUPPLIED BY BOEING. PROVIDE ANCHORAGE SIMILAR TO EXISTING JBT JETPOWER 111 UNIT. 3. BOND GROUND POWER UNITS TO BUILDING STEEL ACCORDING TO MANUFACTURER AND NEC REQUIREMENTS. 4. PROVIDE 60HZ CONDUCTORS AND CONDUIT FROM PANEL 1D6 TO GENERATORS. 5. INSTALL 600A MAIN CIRCUIT BREAKERS IN PANEL 1D6-3 (TWO TOTAL, ONE PER GPU). 6. PROVIDE 400HZ SPIRAL WOUND CONDUCTORS BETWEEN GPU#2 AND NEW DISCONNECT SWITCH. RE -PURPOSE EXISTING CONDUCTORS FOR GPU#1. 7. PROVIDE AUX STATUS CONTACT CONNECTIONS BETWEEN JETPOWER III GROUND POWER UNITS AND 400HZ ALARM PANEL. 8. TEST, COMMISSION AND TRANSFER POWER FROM EXISTING PORTABLE GPU TO PARALLELED GPU #1 AND #2 BY FINALIZING CONNECTION BETWEEN 400HZ GENERATORS AND PANEL 1D6-3 MAIN BREAKERS, 9. VERIFY VOLTAGE AND ADJUST GROUND POWER UNIT SETTINGS AS REQUIRED FOR PROPER OPERATION. DRAWN S.GARRE I I CHECKED S.GARREI I DATE 08.03.18 08.03.18 SUBTITLE ELI 8O7S9 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 NOTES, SYMBOLS AND ABBREVIATIONS REVIEWED .FOR COMPLIANCE WITH FPA 70 m NEC SEP 2 8 2018 City of.Tukwil BUILDING DIVISION RECEIVED MN OF TUKWILA AUG 31 2018 z ERMVIIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED 08.03.18 08.03.18 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM 13 -YARD SHEET E16 JOB NO. 35379 COMP NO. DWG NO. M.F.C. -003-E1 B D 30/20 M 0 0 GROUNDING GROUND CABLE CONNECTION GROUND ROD CONNECTION GROUND CABLE PIGTAIL GROUND CABLE (UNDERGROUND) POWER — GENERAL PANELBOARD, 208Y/120V, 3 PHASE PANELBOARD, 480V OR 480Y/277V, 3 PHASE PANELBOARD, 400 HZ, 200/115V, 3 PHASE PANELBOARD, 28 VDC, POSITIVE AND NEGATIVE EQUIPMENT IDENTIFICATION "X" DENOTES EQUIPMENT NUMBER "Y" DENOTES HP OR AMPS CIRCUIT BREAKER ENCLOSURE CIRCUIT BREAKER DISCONNECT SWITCH DISCONNECT SWITCH (FUSED OR UNFUSED) SWITCH RATING/FUSE RATING MAGNETIC MOTOR STARTER MAGNETIC MOTOR STARTER (COMBINATION) MANUAL MOTOR STARTER TRANSFORMER (SIZE AS SHOWN, IN KVA) JUNCTION BOX OFF/ON SELECTOR SWITCH CONTROL STATION STOP–START PUSHBUTTON CONTROL STATION 460 VOLT MOTOR (SIZE AS NOTED) 208 VOLT OR 240 V MOTOR (SIZE AS NOTED) 115 VOLT MOTOR (SIZE AS NOTED) CONTACTOR RACEWAYS EXPOSED CONDUIT RUN (TYPE AS NOTED) CONCEALED CONDUIT RUN (TYPE AS NOTED) FLEXIBLE CONDUIT RUN CONDUIT HASH MARK DESIGNATIONS PHASE CONDUCTOR NEUTRAL CONDUCTOR GROUND CONDUCTOR ISOLATED GREEN GROUND CONDUCTOR CIRCUIT SOURCE PANEL/CIRCUIT BREAKER N0.(S) ) CONDUIT TURNS DOWN 0 CONDUIT TURNS UP CONDUIT ONLY C.O. PLAN SYMBOLS 15 1 20 Iltc 20 60 POWER RECEPTACLES SINGLE, 2–POLE, 3–WIRE, PARALLEL BLADE, NEMA 5-15 GROUNDING RECEPTACLE, 15 AMP, 120 V, HUBBELL 5262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2–POLE, 3–WIRE, PARALLEL BLADE, NEMA 5-15 GROUNDING RECEPTACLE, 15 AMP, 120 V, HUBBELL 5262 OR EQUAL PER BOEING STANDARDS DUPLEX, 2–POLE, 3–WIRE, STRAIGHT BLADE, NEMA 5-20 GROUNDING RECEPTACLE, 20 AMP, 120 V, HUBBELL 5362 OR EQUAL PER BOEING STANDARDS (2) SINGLE, 2–POLE, 3–WIRE, EXPLOSION–PROOF (GROUND THRU EXTRA POLE & SHELL) 20 AMP, 120 V, CROUSE–HINDS CPS152-102 RED=(1) HOT, WHT=(2) NEUT., PLAIN=GROUND 480 VAC, 4–POLE, 3–WIRE RECEPTACLE (GROUND THRU EXTRA POLE & SHELL) 60 AMP, CROUSE–HINDS ARE 6425 LIGHTING REFER TO SHEET E500 FOR FIXTURE SYMBOLS AND SCHEDULE COMMUNICATIONS TELEPHONE OUTLET DUPLEX TELEPHONE OUTLET T O 480:120 800:5 AS E19-1 400 A M. BKR. 3 PH, 4 W E19-3 225 A M. BKR. 3 PH, 4 W OR SINGLE LINE TRANSFORMER (DASHED LINE INDICATES ELECTROSTATIC SHIELD) SURGE ARRESTER CIRCUIT BREAKER DRAW–OUT TYPE POTENTIAL TRANSFORMER QUANTITY & RATIO AS SHOWN CURRENT TRANSFORMER QUANTITY & RATIO AS SHOWN AMMETER w/SWITCH VOLTMETER w/SWITCH WATTHOUR METER 480V OR 480Y/277V PANELBOARD (RATINGS AS NOTED) 208V OR 208Y/120V PANELBOARD (RATINGS AS NOTED) COMBINATION STARTER CONTROLLER OR MCC CUBICLE NUMBER STARTER SIZE POWER FACTOR CORRECTION CAPACITOR MOTOR HORSEPOWER WIRING DIAGRAM SYMBOLS SINGLE LINE FUSED SWITCH M.V. DISCONNECT SWITCH L.V. DISCONNECT SWITCH INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL FEEDER TYPE DESIGNATION GENERATOR TRANSFER SWITCH Fp DISCONNECT SWITCH H L~ nr'n / \ INTERLOCK K=KEY M=MECHANICAL E=ELECTRICAL SCHEMATIC DISCONNECT SWITCH FUSE CIRCUIT BREAKER TRANSFORMER GROUND CONNECTION PILOT LIGHT * INDICATES COLOR PUSHBUIION —0 o— MOMENTARY CONTACT NORMALLY OPEN PUSHBUTTON —n 1 c}--- MOMENTARY CONTACT NORMALLY CLOSED OFF „- ON SELECTOR SWITCH MAINTAINED CONTACT -0— TWO POSITION 2 —;--2 SELECTOR SWITCH MAINTAINED CONTACT THREE POSITION SCHEMATIC SOLENOID VALVE PRESSURE SWITCH – N.C. OPENS ON RISING PRESSURE PRESSURE SWITCH – N.O. CLOSES ON RISING PRESSURE FLOAT OR LEVEL SWITCH – N.C. OPENS ON RISING LEVEL FLOAT OR LEVEL SWITCH – N.O. CLOSES ON RISING LEVEL FLOW SWITCH – N.C. OPENS ON INCREASE IN FLOW FLOW SWITCH – N.O. CLOSES ON INCREASE IN FLOW TEMPERATURE SWITCH – N.C. OPENS ON RISING TEMP TEMPERATURE SWITCH – N.O. CLOSES ON RISING TEMP o— LIMIT SWITCH – N.C. —oma a LIMIT SWITCH – N.O. --0-I I-0— „No RELAYS & COILS *=TYPE M= MOTOR STARTER CR=CONTROL RELAY C=CONTACTOR TR=TIME DELAY OR TIMING RELAY N.O. CONTACT N.C. CONTACT N.O. – ON DELAY CONTACT \LC. – ON DELAY CONTACT N.O. – OFF DELAY CONTACT N.C. – OFF DELAY CONTACT .~REVIEWED FOR C©MPLIANCE WITH I9FPA 70 - NEC • SEP 2 8 1018 BUILDING DIVISION City of .Tukwila GENERAL NOTES 1. CONDUIT: EMT, UNLESS OTHERWISE NOTED, UP TO 2". FOR SIZES ABOVE 2" AND FOR EXPOSED CONDUIT IN MANUFACTURING AND HIGH BAY AREAS INSTALLED LESS THAN 4 FT. ABOVE FINISHED FLOOR LEVEL USE RIGID STEEL CONDUIT. ALL CONDUITS AND FITTINGS FOR 400HZ SYSTEMS TO BE RIGID ALUMINUM. 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, INSULATION TYPE THHN/THWN, UNLESS OTHERWISE NOTED. USE #14 AWG FOR LOW VOLTAGE CONTROL WIRING. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS AS FOLLOWS: A 0 (LEFT BUS IN PNL) B 0 (CENTER BUS IN PNL) C 0 (RIGHT BUS IN PNL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND 208Y/120V 480Y/277V BLACK RED BLUE WHITE GREEN GREEN WITH BROWN ORANGE YELLOW GRAY GREEN YELLOW TRACER 4. DYMO LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH WITH CIRCUIT IDENTIFICATION. 5. POST NEW OR REVISED PANEL SCHEDULES INSIDE PANELS UPON COMPLETION OF JOB. PROVIDE #12 AWG INSULATED CONDUCTOR, OR OTHER APPROVED PULLING CABLE, AS A PULL–WIRE IN ALL CONDUITS MORE THAN 5 FEET IN LENGTH. 7. IDENTIFY PANELS WITH LAMINATED PHENOLIC NAMEPLATES IN ACCORDANCE WITH SPECIFICATION SECTIONS 16195, ELECTRICAL IDENTIFICATION AND 16470, PANELBOARDS. L ISSUE FOR CONSTRUCTION AUGUST 10, 2018 ABBREVIATIONS AF AFF AHU AL AT AWG CB CMCS CO DED EF EMT EWC FVNR GFI GND HP IMC kcMIL LV M.BKR. MCC MLO NEC N/A NC NO PA PH PNL PVC RF SWBD SWGR SF ST TBD TD THHN THWN T/S U�I VFD WP X FM R XP M/G FRAME RATING IN AMPS ABOVE FINISHED FLOOR AIR HANDLING UNIT ALUMINUM TRIP RATING IN AMPS AMERICAN WIRE GAUGE CIRCUIT BREAKER CENTRAL MANAGEMENT CONTROL SYSTEM CONDUIT ONLY DEDICATED EXHAUST FAN ELECTRICAL METALLIC TUBING ELECTRIC WATER COOLER FULL VOLTAGE, NON–REVERSING GROUND FAULT INTERRUPTER GROUND HORSEPOWER INTERMEDIATE METAL CONDUIT THOUSAND CIRCULAR MILS LOW VOLTAGE MAIN BREAKER MOTOR CONTROL CENTER MAIN LUGS ONLY NATIONAL ELECTRICAL CODE NOT APPLICABLE NORMALLY CLOSED NORMALLY OPEN PAGING SYSTEM PHASE PANEL POLY–VINYL CHLORIDE (CONDUIT) RETURN FAN SWITCHBOARD SWITCHGEAR SUPPLY FAN SHUNT TRIP TO BE DETERMINED TIME DELAY WIRE INSULATION TYPE WIRE INSULATION TYPE TWISTED & SHIELDED UNIT HEATER VARIABLE FREQUENCY DRIVE WEATHER PROTECTED TRANSFORMER EXPLOSION–PROOF MOTOR GENERATOR REFER TO N.E.C. REFER TO N.E.C. Gw1..�1 i D Uri OF TUKWILA AUG 31 2018 PERMIT CENTER CASNE E ELECTRICAL AND ENGINEERINGTECHNOLOGY CONSULTANTSINC. 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW, CASNE. COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A ISSUE FOR CONSTRUCTION SMD TB JMK 03.14.96 B REPLACE 400 HERTZ GENERATORS 32317 CASNE CEC 02.01.17 RECORD DRAWING 32317 CASNE SHG 06.26.17 RECONCILED TO VAULT NO RM 03.27.18 C INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.10.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. DANG DATE CHECKED T. BENNEII SUBTITLE ELECTRICAL LEGEND CURRENT REVISION 35379 SYMBOL DATE 08.10.18 ENGINEER S. DANG CHECKED T. BENNE! I APPROVED J. KOKOCZKA APPROVED K. RAMBALDINI 02.12.96 TITLE ELECTRICAL MASTER INCREASE 400HZ POWER SYSTEM BUILDING 13-003 Dev. Center,Wa SHE E1A OB NO. MFC -95060 COMP N DWG NO. 13-03–E1A C JE SM v ABY LAND USE CODE TUKWILA, WASHINGTON ZONING MANUFACTURING INDUSTRIAL CENTER/HEAVY INDUSTRIAL (MIC/H) REPLACED IMPERVIOUS SURFACE: 0 SF (0.00 AC) ESTIMATED EARTHWORK QUANTITIES: CUT 0 CY (0 CY EXPORT) FILL 0 CY (0 CY IMPORT) TOTAL 0 CY (0 CY) DOJECT 1NFOMA1iO SCOPE OF WORK: ALL WORK APPLIES TO 13-03 BUILDING: CIVIL: PROVIDE STRUCTURAL ANCHORING FOR 400HZ GENERATORS ELECTRICAL: RE -INSTALL GPU #1 (PROVIDED BY BOEING). INSTALL A SECOND JBT 400HZ 180KVA GROUND POWER UNIT (GPU #2). PROVIDE CONDUIT AND CONDUCTORS FROM PANEL 1D6 TO GPU AND FROM GPU TO PANEL 1D6-3. PROVIDE 400HZ FEEDER PROTECTION ON EXISTING GENERATOR 1 AND NEW GENERATOR 2 OUTPUTS IN PANEL 1D6-3 GENERAL NOTES: 1. ALL WORK SHALL CONFORM TO THE WSDOT STANDARD SPEC. 2016 EDITION, CURRENT WSDOT STANDARD PLANS, AND CITY OF TUKWILA REGULATIONS. 2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE BEGINNING WORK AND SHALL NOTIFY THE BOEING PROJECT MANAGER OF ALL DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS. 3. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S WRITTEN RECOMMENDATIONS. BOEING CONTACT: SUNG CHO FACILITIES ENGINEER P. 0. BOX 3707, MS 46-87 SEATTLE, WA 98124-2207 TELEPHONE: 206-612-6953 VERTICAL DATUM: NAVD 88 BENCHMARK: CITY OF SEATTLE SNV-5296 BRASS CAP 25' S OF WHEELCHAIR RAMP AT SE CORNER OF INTERSECTION OF E MARGINAL WAY S AND S 96TH PL ELEVATION = 18.14' N NCR AS BOF 00 / POW -H SYS O8// SSS/9 BOEING MILITARY FLIGHT CENTER 10002 EAST N/ARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 vcr\ ITY MA PROJECT SITE FROM DOWNTOWN SEATTLE 900 99 \\ OXBOW 3'IPGE EXIT 158 OXBOW LOT EXIT 157 - 99 EAST MARGINAL WAY CORPORATE PARK FRON SEATTLE -TACOMA AIRPORT DEVELOP v E\TAL 599 TUKWILA TES FROM KENT & AUBURN NO SCALE EXIT I57 900 AREA MA SITE A 100C2 EAST v1AKl Li <W I LA, WA J J CESS: \AL WAY SOUT S-I\GTO\ PROJECT SITE 7-251 OXBOW PARKING LOT LOOHZ GPU EPLACEv E\ TL CATIO\ NO SCALE M IN SET DRAWING # SHEET # DRAWING TITLE REV DATE GENERAL • 13 -003 -GO GO COVER SHEET - 08.10.18 ELECTRICAL • 13-003-E1A E1A ELECTRICAL LEGEND C 08.10.18 • 13-003-E1B E1B NOTES, SYMBOLS AND ABBREVIATIONS - 08.10.18 • 13-003-1E4AR 1E4AR ONE LINE DIAGRAM - 60 HZ POWER (REMOVAL) B 08.10.18 • 13-003-1E4ER 1E4ER ONE LINE DIAGRAM 400 HZ POWER SYSTEM (REMOVAL) E 08.10.18 • 13-003-1E2R 1E2R 480 VOLT MAIN POWER PLAN (REMOVAL) C 08.10.18 • 13-003-1E160R 1E16OR 400HZ & 28V DC POWER PLAN (REMOVAL) D 08.10.18 • 13-003-1E4A 1E4A ONE LINE DIAGRAM - 60 HZ POWER B 08.10.18 • 13-003-1E4B 1E4B ONE LINE DIAGRAM - 60 HZ POWER D 08.10.18 • 13-003-1E4E 1E4E ONE LINE DIAGRAM 400 HZ POWER SYSTEM E 08.10.18 • 13-003-1E2 1E2 480 VOLT MAIN POWER PLAN C 08.10.18 • 13-003-1E9 1E9 GROUNDING C 08.10.18 • 13-003-1E160 1E160 400HZ & 28V DC POWER PLAN D 08.10.18 • 13-003-2E160 2E160 400HZ & 28V DC POWER PLAN F 08.10.18 • 13-003-E508 E508 DETAILS D 08.10.18 • 13-003-E524 E524 DETAILS 400HZ & ANTENNA ALARM PANEL E 08.10.18 • 13-003-E535 E535 LAYOUTS 1ST / 2ND / 3RD FLOORS C 08.10.18 LL18 07 S8 ISSUE FOR CONSTRUCTION AUGUST 10, 2018 REVIEWED FOR— COMPLIANCE WITH NFPA70 - NEC SEP 2 8 2018 City of Tukwila BUILDING D I(3t\1 RECEIVED CITY OF TUKWILA AUG 31 2018 PERMIT CENTER CASNE ENGINEERING, INC. ELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 181-085 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE INCREASE 400HZ POWER SYSTEM 35379 CASNE SHG 08.03.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. KREISCHER DATE 11.28.16 CHECKED B. LESLIE ENGINEER S.GARRETT CHECKED S.GARRETT APPROVED APPROVED 11.28.16 02.01.17 SUBTITLE COVER SHEET CURRENT REVISION 35379 SYMBOL DATE 08.10.18 02.01.17 TITLE GENERAL INCREASE 400HZ POWER SYSTEM 13-YRD M.F.C. SHEET GO JOB NO. DWG NO. 35379 13-003-G0 COMP NO.