Loading...
HomeMy WebLinkAboutPermit EL18-0777 - POTTER RESIDENCE - INSTALL 5.36KW PHOTOVOLTAIC SYSTEMPOTTER RESIDENCE 3407 S 140 ST ELI 8-0777 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1523049121 3407 S 140TH ST Project Name: POTTER RESIDENCE ELECTRICAL PERMIT Permit Number: EL18-0777 Issue Date: 10/1/2018 Permit Expires On: 3/30/2019 Owner: Name: Address: Contact Person: Name: POTTER GLENN+BRUNK WENDELL 3407 S 140TH ST, TUKWILA, WA, 98168 WENDY WENRICK Address: 3211 MARTIN LUTHER KING JR WAYS S, STE B , SEATTLE, WA, 98144 Contractor: Name: A & R SOLAR Address: 3211 MLK J WAY S - SUITE B , SEATTLE, WA, 98144 License No: RSOLAS*903JM Lender: Name: Address: Phone: (206) 707-9937 Phone: (206) 707-9937 Expiration Date: 5/20/2020 DESCRIPTION OF WORK: INSTALLING A 5.36KW PHOTOVOLTAIC SYSTEM ON THE ROOF Valuation of single family: $15,212.00 Valuation of mf/comm: $0.00 Type of Work: ADDITION Fees Collected: $74.56 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Resodential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature: 2017 2017 2017 2015 ("?j Date: 101�� hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development pite___and agree to the conditions attached to this permit. Signature: Print Name: CJ1c e r4- ris h Date: X07(/ /g3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall) be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/:www.TukwilaWA. Electrical Permit No. / D 0111 Project No. Date Application Accepted: Date Application Expires: ID 10 (For office use an y) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3407 S 140th St Tenant Name: Potter PROPERTY OWNER Name: Wendy Wenrick Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Name: Glenn Potter Email: permits@a-rsolar.com Tukwila Business License No.; BUS -0996237 Address: 3407 S 140th St City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Wendy Wenrick Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: (206) 707-9937 Email: permits@a-rsolar.com King Co Assessor's Tax No.: 1523049121 Suite Number: Floor: New Tenant: ❑ Yes ..No ELECTRICAL CONTRACTOR INFORMATION Company Name: A and R Solar SPC Address: 3211 Martin Luther King Jr. Way S, Suite B City: Seattle State: WA Zip: 98144 Phone: (206) 707-9937 Fax: Cont. Reg No.: RSOLAA*903JM Exp Date: 05/20/2018 Tukwila Business License No.; BUS -0996237 Valuation of Project (contractor's bid price): $ 15,212 Scope of Work (please provide detailed information): Installing a 5.36 kW Photovoltaic System on the roof Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes m No Type of Use: Grid Tied Solar System Type of work: ❑ New m Addition ❑ Service Change ❑ Low Voltage 0 Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ® Seattle City Light W:\Pennit CenterWpplications-Hendoucs\Pemtit ApplicationslPDF's\Electrical Permit Application Revised I-1-17.docx Revised: January 2017 bh O Remodel 0 Tenant Improvement O Telecommunication 0 Temporary Service Page I of 2 Auk RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5155.91 (including an attached garage) ❑ Garages, pools, spas and outbuildings 583.54 ea O Low voltage systems (alarm, furnace thermostat) $61.05 ea RESIDENTIAL REMODEL AND SERVICE CHANGES 0 Service change or alteration 583.54 (no added/altered circuits) O Service change with added/altered circuits 583.54 number of added circuits $12.00 ea ▪ Circuits added/altered without service change 555.69 (up to 5 circuits) ❑ Circuits added/altered without service change 555.69 (6 or more circuits) 57.65 ea O Meter/mast repair 569.62 O Low voltage systems 561.05 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 566.30 ❑ Temporary service (generator) 582.52 O Manufactured/mobile home service 587.98 (excluding garage or outbuilding) ❑ Carnivals 582.21 Number of concessions 511.02 ea Each ride and generator truck 511.02 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: -Te-S3-k---14-1 CLIV-fan Date: Day Telephone: 36o-3/4- a Z-6 d Mailing Address: 3211 Martin Luther King Jr way S, Suite B. Seattle, WA 98144 City W:\Permit Center \Applications-Handouts\Permit Applicauons\PDFs\Electrical Permit Application Revised 1-1-17.docx Revised: January 2017 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $74.56 EL18-0777 Address: 3407 S 140TH ST Apn: 1523049121 $74.56 Credit Card Fee $2.17 Credit Card Fee R000.369.908.00.00 0.00 $2.17 ELECTRICAL $69.61 PLAN CHECK FEE R000.345.832.00.00 0.00 $13.92 PERMIT FEE SINGLE FAMILY R000.322.101.00.00 0.00 $55.69 TECHNOLOGY FEE $2.78 TECHNOLOGY FEE R000.322.900.04.00 0.00 $2.78 TOTAL FEES PAID BY RECEIPT: R15360 $74.56 Date Paid: Monday, September 10, 2018 Paid By: A & R SOLAR CORP Pay Method: CREDIT CARD 02470J Printed: Monday, September 10, 2018 11:00 AM 1 of 1 SYSTEMS Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/10/2018 10:59:52 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********1542 K TRAN AMOUNT: $74.56 APPROVAL CD: 02470J RECORD #: 000 CLERK ID: Rachelle X (CARDHOLDER'S SIGNATURE) I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 9/10/2018 ,,01111111k :••■•••,` CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/10/2018 10:59:52 AM CREDIT CARD SALE MASTERCARD CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: **********1542 $74.56 02470J 000 Rachelle Thank you! Customer Copy K Page 2 of 2 https://classic.convergepay.comNirtualMerchant/transaction.do?dispatchMethod=printTra... 9/10/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - Permit Inspection Request Line (206) 438-9350 Project: , / Type of Inspection: 4------. tildkC— Addres : , 5 ., MO _sr: Date Called: Date Wanted: ... ... Special Ins cuo s: -N Requester: PhoneNo: & (TIC Approved per applicable codes. COMMENTS: ElCorrections required prior to approval. Inspector: Date: 7/0I REINSPECTIOI4 FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Modules C> Optimizers Roof top 3 box O� Inverters Disconnect Co -located with Net Meter String 1 8 modules String 2 8 modules FILE CC", If Perrrgt-U'6-O'1'11 /\./11k, 1 1 'EVlc ir.cv :iwl i2 JrGJi ct t^^ C:Crn cni C..,, L.Q. Ref. 173 1 AA—( pprmval of cG+JLdi LJ:.,..a iAesi+ut t Yts C.:3031 ii a t cc the violation of any ac:optcd cc::3 cr cr c i; ;.,;1:,,;„ r.;, pf approved Field Copy and conditions is ac :, tz:..I. : 1 1 oof top j- 1 box ____J +/- Line Load I Production Meter �ocated with NeMeter(exterior) J Line Load By: Date: to/01 /PP City of Tukwila BUILDING DIVISION /\ j Conductor Schedule General Notes: Utility: Seattle City Light 1. EGC Where exposed to physical damage will be #6AWG Bare CU 2. NEC 690.12: Rapid Shutdown initiated by Toss of Grid or AC Disconnect Equipment Schedule Category Equipment QTY Modules LG -335 N 1 C -A5 16 :pt2 Optimizers P370 SolarEdge Optimizer 16 Jbox j -box 1 J 4 Inverters Solar Edge* SE5000H 1 5 Disconnect DG221URB 30A 240V 2 Pole I General Duty, No Fuse 1 6 MeterBase MeterBase-125A 4Jaw w/ 3.5" AWCAP 1 Monitoring Solaredge PV Monitoring 1 Inverter Specs Watts (w) Inverter Output(A) AC Voltage # of Inverters OCPD Solar Edge* SE5000H -;5000 21.00 240 1 30 *****N/A***** 0 0.00 0 0 0 Module Specs Watts (w) Imp Vmp Voc Isc LG -335 N 1C -A5 335 9.8 34.1 41 10.5 Main Service Panel (lph 240V Service) Main Breaker: 150A Bus Rating:200A Solar OCPD: 2p30A Temp—kruste RVI COMPLIANCE WITH NFPA 70 0 30.9 44.7 SEP 2 7 2018 City of Tukwila BUILDING DIVISION RE0E1`1E0 CI -[Y OF TUKWILA SEP 1 0 2018 PERMIT CENTER ‘/I(10/ 01 11 Ref. Conductor t�esrintion AL/CU Wire Gauge Distance (ft) Number of Wires Height / roof (in.) Temp Rating Wire Type Conduit Type Min. Conduit Base Amp. Temp Correct. Fill Derate Derated Ampacity 75deg rating Current (125%) EGC Voltage Drop A (String) to Jbox CU 10 50 2 0.875+ 90 w Wire 600V 40 0.96 100% 38.40 30 18.75 #6 0.23% B Jbox to Inverter CU 10 50 6 0 90 THHN,THWN-2 EMT 0.75" 40 0.96 80% 30.72 30 18.75 #10 0.23% C Inverter to Disconnect CU 10 10 3 0 90 THHN,THWN-2 EMT 0.5" 40 0.96 100% 38.40 30 26.25 #10 0.22% D Disconnect to MSP CU 10 10 3 0 90 THHN,THWN-2 EMT 0.5" 40 0.96 100% 38.40 30 26.25 #10 0.22% Voltage drop: 1.26% A&R`C >__, ,f 3211 Martin Luther King 1r Way 5. Seattle, WA 98144 (206)707-9937-. THIS DRAWING CONSTITUTES THE CONnTDE1mAL INrcartsT1EN Cr ABR SD YAR AND ITS RECEPTOR POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATTION DISCLOSED HERE IN NOR ANY RIGHT TO REPRODUCE THIS DRAWING 0 ANY PART HERE IN WITHOUT THE WRITTEN CONSENT OF ARA SOLAR. C U sia a M u 1 0. oo co a in co � J o ' 0< L c '.o1-1 a , ,u7 r C7 0 0 v M 1— REVISIONS Rev. #: Date: Aug 28, 248 Designed by: Daniel H. PM: Arthur Eith (612) 298-1795 Current Date:Aug 28, 2018 PV -E1 Single Line • 0 ttil C 7. P: Ti, —9 s.: Ca. (Ts EL 5 -C7• ' ..• 't :' LLI- cc -(.. : rC,.. .: 7---,_ , .'• 0 '''* 7.• ' - 4 V) 0 :-•"' - '''. C-.• i— - ..----- as ;IA • •, : ,.c •••-• (...- i: Q1 0 • "' 1! -- .., 0 Z t_... .... ABERSO, -\:\ 3211 Martel Luther !Ong Jr Way 5. WA 98144 (206)707 9937 PV Electrical Calculations Inverter Specs Watts (w) Inverter Output(A) AC voltage # of Inverters OCPD Comb. AC out.(A) Combined OCPD EGCSeattle, (AC) Array Specs (Adjusted for Temperature) Solar Edge* SE5000H 5000 21.00 240 1 30 Inverter Solar Edge* SE5000H *****N/A***** *****N/A***** 0 0.00 0 0 0 21.0 30 #10 Mppt Input 1 2 3 1 2 Module Specs Watts (W) Imp Vmp Vac Isc Temp. Coef V(oc) EGC (DC) Amperage (Imp) 7.6. 7.6. 0.00 #DIV/0! #DIV/ 0! #DIW01 THIS DRAWING OONSTrUTES THE CONFFIDENTIAL INFORMATION OF MLR SO,AR iFisEr:f;arEAFFEEL, NOR AM RIGH1 M REPRODUCE THIS 0=1::° nor 171Z:Vs= LG-335N1C-A5 335 9.8 34.1 41 10.5 Voltage (Vmp) 380.0 380.0 380.0 0.0 0.0 0.0 Temp. Adjusted 30.9 44.7 -0.28 #10 Max Voltage(DC) 480.0 480.0 480.0 0.0 0.0 0.0 Project: Potter, Glenn 5,16118LDC Glenn Potter (206) 659-1198 3407 S 140th St. Tukwila, WA 98168 Optimizer? P370 So arEdge Optimizer Max current output: 15A, Ma D foh Max Amps (DC) 15.0 15.0 0.0 0.0 0.0 0.0 Equipment Solar Edge* SE5000H *****N/A***** VV 1 COMPLIANCE WITH Max Array Power(STC): 5.36 kW DC Mppt Input 1 2 3 1 2 3 NFPA 70 - NEC Max Continuous AC Power: 5kW AC Module LG-335N1C-A5 ******SELECT****** # Modules per String 8 8 0 0 0 0 SEP 2 7 2018 Interconnection Calcs Site Conditions # Parallel Strings 1 1 0 0 0 0 Main Breaker 200 ASHRAE Site: Seaffle # of Mods per Mppt 8 8 0 0 0 0 Bus Bar - 200- • Low Temp (F) 19 # of Mods/inverter 16 0 City of Tulaniila Max PV OCD Allowed 40 High Temp (*F) 84 # of Inverters 1 0 BUILDING DIVISDN PV OCPD Device Used 30 High 2% Temp (7) 91 Total # of Modules 16 Tap or Breaker? Breaker Ref. Conductor Desciption AL/CU Wire Gauge Distance (ft) Number of Wires Height / roof (in.) TempConduit Rating Wire Type Type Min. Conduit Base Amp. Temp Correct. Filt Derate Derated Ampacity 75deg rating Current (125%) EGC Voltage Drop A Suing) tobox CU 1050 2 . 0875+ 90 PV Wite 600V 40 0.96 100% 38.40 30 18.75 #6 0.23% B Jboxtolnverter CU 10 50 6 0 90 mmtniwN-2 EMT 075" 40 0.96 80% 30.72 30 18.75 #10 0.23% C inverter to Disconnect_CU 10 10 3 0 90 1HHN,THVAI-2 EMT 40 0.96 100% 3840 30 26.25 #10 0.22% REVISIONS D Disconnect to MSP CU 10 10 3 0 90 EMT 05" 40 0.96 100% 3840 30 26.25 #10 0.22% Re": Date: Aug 28, 2018 E F ' I-lc:GER ED G criv LP. TIIKWIL,- Total Voltage Drop: 0.90% Designed by: Daniel H. SEP PERMIT 1 0 2018 CENTER PM: Arthur Elth (612) 298-1795 Current Date:Aug 28, 2018 PV-E2 Electrical Calculations Scope of Work System Size: 5.36kw DC 5.0kw AC Modules: LG335N1C-A5 (Tuxedo) Inverter(s): SolarEdge 5000H -US Racking: Ironridge XR100 Table of Contents: Cover Page PV -G1 Site Overview PV -E1 Single Line PV -E2 Electrical Calculation PV -A1 Roof Layout PV -G2 Ground/ Electrician As-Builts PV -G2.1 Micro/optimizer map PV -G3 Placards PV -G4 Equipment BOM General Notes: Additional Electrical Work: ECEIVF-:D OF TUKWL SEP 1 0 2018 PERMiT CENTER A&RSC 3211 Martin Luther King Jr Way S Seattle, WA 98144 (2061707-9937 THIS DRAWING CONSTITUTES THE CONFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR POSSESSION DOES NOT 0044550 44444 RIGHT IN OR LICENSE TO USE IT 04. 5010 INFORMAMON DISCLOSED HERE IN NOR AN, 04111 10 REPRODUCE I HIS DRAWING OR ANY PART HERE IN WITHOUT THE WRITTEN CONSENT Of AetIl SOLAR_ • ON e: Aug28,2018 Deslgned by: Daniel H. PM: Arthur EItt (612) 298-179 Current Date:Aug 28, 2018 Cover Page Required Setbacks from Ridge: 18" Maximum Mount Soacinp: 72" Roof Type: Comp Roof Pitch: 28° Roof Area: 2,494 ft2 Array Area 298 ft2 Array to Roof Coverage 12% • Interior: MSP Exterior: AC Disconnect, Production Meter, Net Meter REVIEWED .FOR COMPLIANCE WITS NFPA 70 - NEC SEP 2 7 2018 City of Tukwila BUILDING DIVISION:. RECEIVED CITY OF TUKWIL(.. SEP 1 0 2018 ')ERA/11T CENTER Rail Selection Guide (use for top and bottom rail for each row) Row of (#) mods Rail tvoe1+ rail tvoe2 (8)Portrait (1)14', (1)14' A L 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFFIDENTI L INFORMATION OF A&R SOLAR AND ITS RECEPTOR POSSESSION DOES NOT CONFER ANY IGHT IN OR LICENSE TO USE IT OR THE INFO MATTION DISCLOSED HERE IN NOR ANY RIGHT TO REPRODUCE THIS DRAWING 0 ANY PART HERE IN WITHOUT THE WRITTEN CONSENT OF A&R SOLAR. REVISIONS Rev. #: Date: Aug 28, 2018 Designed by: Daniel H. PM: Arthur Eith (612) 298-1795 Current Date:Aug 28, 2018 PV -A1 Roof LAyout Modules not to exceed height of existing ridge Building height REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC SEP 2 7 2018 Manufactured trusses, 2x6, 24" O.C. 18' Cfl Y OF TUKVV,! SEP 1 0 2018 City of Tukwila BUILDING DIVISION PERMIT CENTE, (sample) Attachment point layout for array. 72" OC Max. IronRidge Flashfoot2 3211 Martin Luther king Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFFIDENTIAL 10000001100 00 ASA SOURR *00 115 RECEPTOR 0050155100 0005 NOT CONIER ANT PONT IN OR LICENSE TO USE IT 00 107 INFORMAITION DISCLOSED 14(00 20 NON AM RIONT TO REPRODUCE TNIS DRAWING 0 ANT PART HERE IN WITHOUT THE WRITTEN CONSENT OP ABA SOIAR. REVISIONS Ray. #t Date: Aug 2B, 2018 Designed by: Daniel H. PM: Arthur Eith (612) 298-1795 Current Date:Aug 28, 2018 PV -G1 Site Overview Load Assumptions: WindExposure "C" WindSpeed 110 mph Attachment Spacing 6 feet Roof Type: Composition Racking Weight: 117 lbs Total Weight: 751 lbs Weight/ Attachment: 31.3 lbs Distributed Toad: 2.55 PSF Side View (Portrait) Pv MODULE RAIL FLASHFOOT2 ROOF MFMBRANF BUILDING STP..UCTUR R IEWED FOF CO LIANCE Wt N NEC SEP 2 7 2018 City of Tukwila II IAllti; f IUICI '1 M - 6'—O" e O t O t +O o I e a e O e RECEIVED CITY OF TUKliW SEP 102018 PERMIT CENTL'4 A&R`OL_,Al 3211 Martin Luther King Jr Way S. Seattle, WA 98144 (206)707-9937 THIS DRAWING CONSTITUTES THE CONFFIDENTIAL INFORMATION OF A&R SOLAR AND ITS RECEPTOR POSSESSION DOES NOT CONFER ANY RIGHT IN OR LICENSE TO USE IT OR THE INFORMATT/ON DISCLOSED HERE IN NOR ANY RIGHT TO REPRODUCE THIS DRAWING OR ANY PART HERE IN WITHOUT THE WRrTTEN CONSENT OF A&R SOLAR. co co (.f) ao rn oo < 1n c CU e -n ,(rcr 3 N Cr) i— EVISIONS Rev. Date: Aug 28, 2018 Designed by: Daniel H. PM: Arthur Eith (612) 298-1795 Current Date:Aug 28, 2018 PV -A2 Attachment plan LG N0ON 2 Mechanical Properties Cells 6 x 10 Electrical Properties (STC *) Module LG335N1C-A5 Celt Vendor LG Cell Type Cell Dimensions * of Busbar Monocrystaltine / N -type 161,7x161.7mm/ 6inches 12 (Multi Wire Busbar) Dimensions (1 x W x H) '1686x1016x40mm 66.38 x 40 x 1.57 inch Front Load 6000Pa Rear Load 5400Pa Weight 18 kg Connector Type Junction Box MC4 P68 with 3 Bypass Diodes Cables 1000mmx2ea Glass High Transmission Tempered Glass Frame Anodized Aluminium Certifications and Warranty Certifications 1TC 61215, IEC 61730-1/-2 UL 1703 IEC 61701 (Salt mist corrosion test) IEC 62716 (Ammonia corrosion test) ISO 9001 Module Fire Performance (USA) Type 1 Fire Rating (CANADA) Product Warranty Class C (ULC / ORD C1703) 12 years Output Warranty of Pmax Linear warranty** ** 1)1st year: 98%, 2) After 1st year 0 55% annual degradation, 3) 25 years 84 8% Temperature Characteristics NOCT 45±3°C Maximum Power (Pmax) 335 MPP Voltage (Vmpp) 34.1 MPP Current (Impp) 9.83 Open Circuit Voltage (Voc) 41.0 Short Circuit Current (Isc) 10.49 Module Efficiency 19.6 Operating Temperature -40 - +90 Maximum System Voltage 1,000 Maximum Series Fuse Rating 20 Power Tolerance (%) 0-+3 * STC (Standard Test Condition): Irradiance 1,000 W/m', Ambient Temperature 25 °C, AM 1.5 * The nameplate power output is measured and determined by LG Electronics at its sole and absolute discretion. '• ne 27p4al charge :n .module efficierry at 200 W/m' :^ -euro., to 1000W/m2 Is -2 0% Electrical Properties (NOCT*) Module LG335N1C-A5 Maximum Power (Pmax) 247 MPP Voltage (Vmpp) 31.5 MPP Current (Impp) 7.83 Open Circuit Voltage (Voc) 38.2 Short Circuit Current (Isc) 8.44 * NOCT (Nominal Operating Cell Temperature): Irradiance 800W/m', ambient temperature 20 °C, wind speed 1 m/s Dimensions (mm/in) 04.1 Pmpp Voc 7%/°C -0.27%/°C Isc 0.03 %/°C Characteristic Curves 000W REVIEW COMPLIANCE NFPA70-NE SEP 2 7 2018 000.9. (V) 'A 20 '00 20 50 20 2" City of Tukwila BUILDING DIVISI ra 2C 25 T .porerunl ('C) North America Solar Business Team LG Electronics USA. Inc 1000 Sylvan Ave, Englewood Cliffs, NJ 07632 Contact: Ig.solar@lge.com www.lgsolarusa.com 90 tKVV1 3 _ e.,th(JOC.$PP 10 2018 Copyright © 2017 LG Electronics. All rights reselrorti? 1I/11 T CENInetion for a Better Life 01/01/2017 H A solar- •. Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US • Specifically designe • Record-breaking efficiency s Fixed voltage inverter for longer strings • UL1741 SA certified, for CPUC Rule 21 grid compliance 1. Extremely small — High reliability without any electrolytic capacitors — Built-in module -level monitoring — Outdoor and indoor installation — Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 1111111110 wave vC_3r_(Er.vDaN., - G `JEDw www.solaredge.us 0 solar C Single Phase Inverters for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US 1 SE3000H-US I SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US OUTPUT Rated AC Power Output 3000 Max. AC Power Output 3000 AC Output Voltage Min.-Nom.- Max. in:Nom.- Max. (211 - 240 - 264) AC Frequency (Nominal) Maximum Continuous Output Currentea 240V GFDI Threshold 12.5 Utility Monitoring, !standing Protection, Country Configurable Thresholds 3800 3800 16 5000 5000 6000 7600 10000 VA 6000 7500 10000 VA 59.3-60-60.501 21 1 25 Yes 32 42 Vac Hz A A INPUT Maximum DC Power Transformer -less, Ungrounded Maximum Input Voltage 4650 5900 Nominal DC Input Voltage Maximum Input Current@240V Max. Input Short Circuit Current 7750 I 9300 Yes 480 11800 I 15500 W Vdc 380 8.5 Reverse -Polarity Protection Ground -Fault Isolation Detection Maximum Inverter Efficiency CEC Weighted Efficiency 10.5 13.5 I 16.5 400 20 27 Vdc Adc 45 Yes 600ka Sensitivity 99 1 99.2 99 Ni:httime Power Consum.tion ADDITIONAL FEATURES Supported Communication Interfaces < 2.5 Adc w Revenue Grade Data, ANSI C12.23 Rapid Shutdown NEC 2014 and 2017 690.12 STANDARD COMPLIANCE RS485, Ethernet, ZigBee (optional), Cellular (optional) Optionafz1 Automatic Rapid Shutdown_ upon AC Grid Disconnect Safety Grid Connection Standards Emissions UL1741, UL1741. SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 IEEE1547, Rule 21, Rule 14 (HI) FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range DC Input Conduit Size / # of Strings / AWG Range Dimensions with Safety Switch (HxWxD) Weight with Safety Switch 3/4" minimum / 20-4 AWG 3/4" minimum / 1-2 strings / 14-6 AWG 17.7 x 14.6 x 6.8 / 450 x 370 x 174 22/10 I 25.1/11.4 I Noise Cooling Operating Temperature Range Protection Rating < 25 Natural Convection 3/4" minimum / 1-3 strings / 14-6 AWG 21.3 x 14.6 x 7.3/540x370 x 185 in / mm 26.2 / 11.9 38.8 / 17.6 lb/kg <50 dBA Natural convection -13 to +140 / -25 to +6001 (-40°F / -40°C option)'') NEMA 3R (Inverter with Safety Switch) For other regional settings please contact SolarEdge support 1�1 Revenue grade inverter P/N: SExxxxH-US000NNC2 For power de -rating information refer to: https://wwwsolaredge.cam/sites/default/files/se-temperature-derating-note-na.pdf Hl -40 version P/N: SExxxxH-USOOONNU4 °F / °C ® SolarEdge Technologies, Inc. All ri are trademarks or registered tradent, are trademarks of their respective ow fits reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE rks of SolarEdge Technologies, Inc. All other trademarks mentioned herein ers. Date: 03/2018/V01/ENG NAM. Subject to change without notice. solar-••: SolarEdge Power Optimizer Module Add -On For North America P320 / P370 / P400 / P405 / P505 PV power optimization at fhc rn — Specifically designed to work with SolarEdge ii — Up to 25% more energy — Superior efficiency (99.5%) — Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization. — Fast installation with a single bolt • Next generation maintenance with module -level monitoring — Module -level voltage shutdown for installer and firefighter safety NDS APAN-C NA-AUSI'RALiA ISRAEL FRANCE f3[I°GLUM TRARE.J iyvlA-RULGARIA-RGNI1N;A-HUNGARY- www.5olaredge.us • SolarEdge Power Optimizer Module Add -On for North America P320 / P370 / P400/ P405/ P505 OPTIMIZER MODEL (typical module compatibility) P320 (for high-power 60 -cell modules) P370 (for higher -power 60 and 72 -cell modules) P400 (for 72 & 96 -cell modules) P405 (for thin film modules) P505 (for higher current modules) INPUT Rated Input DC Powerw Absolute Maximum Input Voltage (Voc at lowest temperature) MPPT Operating Range Maximum Short Circuit Current (lsc) 320 370 400 405 505 48 60 80 125 83 Vdc 8 - 48 8 - 60 8 - 80 12.5 - 105 12.5 - 83 Vdc 10.1 14 Adc Maximum DC Input Current Maximum Efficiency Weighted Efficiency 13.75 12.63 17.5 Adc 99.5 98.8 98.6 Overvoltage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current Maximum Output Voltage OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer STANDARD COMPLIANCE EMC 15 Adc 60 85 Vdc 1 ± 0.1 Vdc Safety RoHS FCC Part15 Class 8, IEC61000-6-2, IEC61000-6-3 IEC62109-1 (class 11 safety), UL1741 Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage Compatible inverters Dimensions (W x L x H) Weight (including cables) Input Connector Output Wire Type / Connector Output Wire Length Operating Temperature Range Protection Rating Relative Humidity 1000 Vdc All SolarEdge Single Phase and Three Phase inverters 128 x 152 x 28 / 5 x 5.97 x 1.1 128 x 152 x 36 / 5 x 5.97 x 1.42 128 x152x50 / 5 x 5.97 x 1.96 128 x 152 x 59 / 5 x 5.97 x 2.32 mm / in 630 / 1.4 750 / 1.7 845 / 1.9 1064 / 2.3 gr /lb MC4w Double Insulated; MC4 0.95 / 3.0 I 1.2 / 3.9 m / ft -40 - +85 / -40 - +185 IP68 / NEMA6P 0- 100 Rated STC power of the module. Module of up to .5% power tolerance allowed. For other connector types please contact SolarEdge PV SYSTEM DESIGN USING A SOLAREDGE INVERTER"Minimum String Length P320, P370, P400 (Power Optimizers) P405 / P505 SINGLE PHASE HD -WAVE SINGLE PHASE 8 THREE PHASE 208V 10 THREE PHASE 480V 18 Maximum String Length (Power Optimizers) 6 8 14 25 25 Maximum Power per String 5700 (6000 with SE7600H-US, SE10000H-US) 5250 6000 12750 Parallel Strings of Different Lengths or Orientations Yes For detailed string sizing Information refer to: http://www.solaredge.corn(sitesidetault/files/string_sizing_na_pdf. RI it is not allowed to mix P405/P505 with P320/P370/1,400/P600/P700/PROO in one string. Ok A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage wit be above the 30V requirement 0) SolarEdge Tr)cOnoloRieN, Inc_ All nghts reserved SOLAPEDGE. the SolarEdge logo, OPTIMIZED BY SOL.AREDGE are trademal Es al t er ed tradematIss of 50101 Edge Technologies, Inc All other trademarks mentioned herem are trademarks 01 their ierrpectrve owners. Date: 03. 2018: VO1 /ENG NAM. Subject to change without notice ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL18-0777 PROJECT NAME: POTTER RESIDENCE SITE ADDRESS: 3407 5 140TH ST X Original Plan Submittal Response to Correction Letter DATE: 09/12/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: PtiP g(‘ Building Division Fire Prevention Public Works 1 1 Structural T Planning Division n Permit Coordinator E PRELIMINARY REVIEW: DATE: 09/13/18 Not Applicable E] Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DUE DATE: 10/09/18 Approved with Conditions Denied (ie: Zoning Issues) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping fl PW Staff Initials: 12/18/2013 A&R Solar Home Espanol Contact ,Safety & Health Claims & Insurance AilIll\ Washington State Department of kl Labor & Industries Page 1 of 3 !Search L&I A -Z Index Help My 1..&.1 Workplace Rights Trades & Licensing A&R Solar Owner or tradesperson Principals CLIPPARD, WILLIAM R, PRESIDENT YATTEAU, ANDREW, VICE PRESIDENT CLIPPARD, WILLIAM R, AGENT Doing business as A&R Solar WA UBI No 602 707 872 3211 MLK J Way S Ste B SEATTLE, WA 98144 206-707-9937 KING County Business type Corporation Parent company Governing persons A AND R SOLAR CORP WILLIAM CLIPPARD ANDREW YATTEAU; DAVID KOZIN; EVAN MANDERBACH; ILicense Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties GENERAL License no. RSOLAS*903JM Effective — expiration 05/20/2010— 05/20/2020 Designated administrator Clippard, William Active. Meets current requirements. Active. Meets current requirements. License type License no. Electrical Administrator CLIPP'VV*902JN Bond CBIC Bond account no. S16249 $4,000.00 Received by L&I Effective date 05/20/2010 05/17/2010 Expiration date Until Canceled Savings No savings accounts during the previous 6 year period. License Violations Help us improve httos://secure.lni.wa,aov/verifv/Detail.asox?Uffl=602707872&LIC=RSOLAS*903JM&SAW= 10/1/2018 A&R Solar Infraction no. ECAML03124 Issue date 06/06/2017 Violation city SEATTLE Type of violation ELECTRICAL CITATION Description Failing to provide proper supervision to an electrical trainee -as required by chapter 19.28 RCW. Satisfied .................... . RCW/WAC 19.28.161 RCW Violation amount $250.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 168,352-00 .............................. Doing business as A&R SOLAR Estimated workers reported Quarter 2 of Year 2018 "51 to 75 Workers" L&I account contact T3 / STEPHANIE HENDERSON (360)902-5598 - Email: HSTE235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments haze been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 04/26/2016 Inspection no. 317939903 Location 19 Main Street Soap Lake, WA 99851 Inspection results date 01/27/2016 Inspection no. 317938661 Location 507 123 Ave NE Bellevue, WA 98006 Inspection results date 12/03/2015 Inspection no. 317937464 Location N Barker Spokane Valley, WA 99216 Inspection results date 08/14/2015 Inspection no. Violations Violations Violations Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602707872&LIC=RSOLAS*903JM&SAW= 10/1/2018